Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Sci Rep ; 11(1): 19910, 2021 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-34620887

RESUMO

Face masks are a primary preventive measure against airborne pathogens. Thus, they have become one of the keys to controlling the spread of the COVID-19 virus. Common examples, including N95 masks, surgical masks, and face coverings, are passive devices that minimize the spread of suspended pathogens by inserting an aerosol-filtering barrier between the user's nasal and oral cavities and the environment. However, the filtering process does not adapt to changing pathogen levels or other environmental factors, which reduces its effectiveness in real-world scenarios. This paper addresses the limitations of passive masks by proposing ADAPT, a smart IoT-enabled "active mask". This wearable device contains a real-time closed-loop control system that senses airborne particles of different sizes near the mask by using an on-board particulate matter (PM) sensor. It then intelligently mitigates the threat by using mist spray, generated by a piezoelectric actuator, to load nearby aerosol particles such that they rapidly fall to the ground. The system is controlled by an on-board micro-controller unit that collects sensor data, analyzes it, and activates the mist generator as necessary. A custom smartphone application enables the user to remotely control the device and also receive real-time alerts related to recharging, refilling, and/or decontamination of the mask before reuse. Experimental results on a working prototype confirm that aerosol clouds rapidly fall to the ground when the mask is activated, thus significantly reducing PM counts near the user. Also, usage of the mask significantly increases local relative humidity levels.


Assuntos
COVID-19/prevenção & controle , Exposição por Inalação/prevenção & controle , Máscaras , Material Particulado/isolamento & purificação , Dispositivos de Proteção Respiratória , SARS-CoV-2/isolamento & purificação , Aerossóis/isolamento & purificação , Microbiologia do Ar , Desenho de Equipamento , Filtração/instrumentação , Humanos , Aplicativos Móveis , Tamanho da Partícula , Materiais Inteligentes/química , Smartphone
2.
Sci Rep ; 11(1): 19930, 2021 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-34620923

RESUMO

Transmission of SARS-CoV-2 by aerosols has played a significant role in the rapid spread of COVID-19 across the globe. Indoor environments with inadequate ventilation pose a serious infection risk. Whilst vaccines suppress transmission, they are not 100% effective and the risk from variants and new viruses always remains. Consequently, many efforts have focused on ways to disinfect air. One such method involves use of minimally hazardous 222 nm far-UVC light. Whilst a small number of controlled experimental studies have been conducted, determining the efficacy of this approach is difficult because chamber or room geometry, and the air flow within them, influences both far-UVC illumination and aerosol dwell times. Fortunately, computational multiphysics modelling allows the inadequacy of dose-averaged assessment of viral inactivation to be overcome in these complex situations. This article presents the first validation of the WYVERN radiation-CFD code for far-UVC air-disinfection against survival fraction measurements, and the first measurement-informed modelling approach to estimating far-UVC susceptibility of viruses in air. As well as demonstrating the reliability of the code, at circa 70% higher, our findings indicate that aerosolized human coronaviruses are significantly more susceptible to far-UVC than previously thought.


Assuntos
Coronavirus Humano 229E/efeitos da radiação , Infecções por Coronavirus/prevenção & controle , Coronavirus Humano OC43/efeitos da radiação , Desinfecção/métodos , Raios Ultravioleta , Inativação de Vírus/efeitos da radiação , Aerossóis/isolamento & purificação , Microbiologia do Ar , COVID-19/prevenção & controle , Simulação por Computador , Coronavirus Humano 229E/isolamento & purificação , Coronavirus Humano 229E/fisiologia , Coronavirus Humano OC43/isolamento & purificação , Coronavirus Humano OC43/fisiologia , Desinfecção/instrumentação , Desenho de Equipamento , Humanos , Modelos Biológicos
3.
PLoS One ; 16(9): e0258151, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34591919

RESUMO

BACKGROUND: Few studies have quantified aerosol concentrations of SARS-CoV-2 in hospitals and long-term care homes, and fewer still have examined samples for viability. This information is needed to clarify transmission risks beyond close contact. METHODS: We deployed particulate air samplers in rooms with COVID-19 positive patients in hospital ward and ICU rooms, rooms in long-term care homes experiencing outbreaks, and a correctional facility experiencing an outbreak. Samplers were placed between 2 and 3 meters from the patient. Aerosol (small liquid particles suspended in air) samples were collected onto gelatin filters by Ultrasonic Personal Air Samplers (UPAS) fitted with <2.5µm (micrometer) and <10 µm size-selective inlets operated for 16 hours (total 1.92m3), and with a Coriolis Biosampler over 10 minutes (total 1.5m3). Samples were assayed for viable SARS-CoV-2 virus and for the viral genome by multiplex PCR using the E and N protein target sequences. We validated the sampling methods by inoculating gelatin filters with viable vesicular stomatitis virus (VSV), and with three concentrations of viable SARS-CoV-2, operating personal samplers for 16hrs, and quantifying viable virus recovery by TCID50 assay. RESULTS: In total, 138 samples were collected from 99 rooms. RNA samples were positive in 9.1% (6/66) of samples obtained with the UPAS 2.5µm samplers, 13.5% (7/52) with the UPAS 10µm samplers, and 10.0% (2/20) samples obtained with the Coriolis samplers. Culturable virus was not recovered in any samples. Viral RNA was detected in 15.1% of the rooms sampled. There was no significant difference in viral RNA recovery between the different room locations or samplers. Method development experiments indicated minimal loss of SARS-CoV-2 viability via the personal air sampler operation.


Assuntos
Aerossóis/isolamento & purificação , Microbiologia do Ar , COVID-19/virologia , SARS-CoV-2/isolamento & purificação , Animais , COVID-19/epidemiologia , COVID-19/transmissão , Chlorocebus aethiops , Hospitais , Humanos , Assistência de Longa Duração , RNA Viral/isolamento & purificação , Células Vero
4.
Sci Rep ; 11(1): 10187, 2021 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-33986353

RESUMO

The severe outbreak of respiratory coronavirus disease 2019 has increased the significant demand of respiratory mask and its use become ubiquitous worldwide to control this unprecedented respiratory pandemic. The performance of a respiratory mask depends on the efficiency of the filter layer which is mostly made of polypropylene melt blown non-woven (PP-MB-NW). So far, very limited characterization data are available for the PPE-MB-NW in terms to achieve desired particulate filtration efficiency (PFE) against 0.3 µm size, which are imperative in order to facilitate the right selection of PP-MB-NW fabric for the development of mask. In present study, eight different kinds of PP-MB-NW fabrics (Sample A-H) of varied structural morphology are chosen. The different PP-MB-NW were characterized for its pore size and distribution by mercury porosimeter and BET surface area analyzer was explored first time to understand the importance of blind pore in PFE. The PP-MB-NW samples were characterized using scanning electron microscopy so as to know the surface morphology. The filtration efficiency, pressure drop and breathing resistance of various PP-MB-NW fabric samples are investigated in single and double layers combination against the particle size of 0.3, 0.5 and 1 µm. The samples which are having low pore dia, high solid fraction volume, and low air permeability has high filtration efficiency (> 90%) against 0.3 µm particle with high pressure drop (16.3-21.3 mm WC) and breathing resistance (1.42-1.92 mbar) when compared to rest of the samples. This study will pave the way for the judicial selection of right kind of filter layer i.e., PP-MB-NW fabric for the development of mask and it will be greatly helpful in manufacturing of mask in this present pandemic with desired PFE indicating considerable promise for defense against respiratory pandemic.


Assuntos
Filtros de Ar , COVID-19/prevenção & controle , Máscaras , Aerossóis/isolamento & purificação , Filtros de Ar/virologia , Desenho de Equipamento , Humanos , Máscaras/virologia , Tamanho da Partícula , Polipropilenos/química , SARS-CoV-2/isolamento & purificação , Têxteis/virologia
5.
Surg Innov ; 28(2): 226-230, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33710929

RESUMO

Background. Exposure to infectious droplets confers a high risk for infection transmission by the SARS-CoV-2 coronavirus. Aerosolizing procedures pose particular concern for increasing healthcare workers' (HCWs) risks of infection. Multiple creative personal protective equipment solutions have been utilized to minimize exposure to infectious particles; however, the overall benefit of many of these devices is limited by a number of factors. Methods. We designed an intubation tent consisting of a metal frame and a clear plastic sheet. The flexible walls of our tent offer increased maneuverability & access, although the efficacy in reducing risk of transmission to HCWs remained unclear. Using an atomizer, particle generator, and matchstick smoke, we simulated the generation of infectious respiratory droplets and aerosols and tested whether our device effectively decreased the concentration of these particles to which a provider might be exposed. Finally, we tested whether the addition of a vacuum fan fit with a high efficiency particulate air filter designed to evacuate contaminated air would influence particle concentrations inside and outside the tent. Results. Droplet dispersion tests with the tent in place showed that the simulated droplet distribution was limited to surfaces within the tent. Aerosol testing under a variety of circumstances consistently showed only a minor rise in particle concentration in the air outside the tent despite an initial peak of particle concentration during generation within. All testing demonstrated declining inside concentrations over time. Conclusions. Our simulations suggest our device has the potential to effectively decrease HCWs' exposure to infectious droplets and aerosolized viral particles.


Assuntos
Aerossóis/isolamento & purificação , COVID-19/prevenção & controle , Intubação Intratraqueal , Equipamento de Proteção Individual , Desenho de Equipamento , Pessoal de Saúde , Humanos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Pandemias , SARS-CoV-2 , Procedimentos Cirúrgicos Operatórios/métodos
6.
J Appl Microbiol ; 131(2): 780-790, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33331057

RESUMO

AIMS: Recovering DNA of airborne micro-organisms (AM) from air is a challenging task. We compared five membrane filters for bioaerosol sampling-mixed cellulose ester (MCE), polyethersulfone (PES), polyamide (PA), polytetrafluorethylene (PTFE) and polyvinylidene fluoride (PVDF)-based on their bacterial, fungal and eukaryotic DNA recoveries. METHODS AND RESULTS: Bacterial, fungal and eukaryotic populations were quantified using quantitative PCR. With a bacterial consortium, PTFE exhibited the best recovery efficiency (113%), followed by PA (92%), PES (86%), MCE (48%) and PVDF (1%). When filters were compared with air, PA was used as a control to normalize results from the others. The bacterial, fungal and eukaryotic DNA recovery ratios were markedly greater in PES (9·3, 11·5 and 10·3 respectively) than in the remaining. Eukaryotic MiSeq sequencing revealed that PES recovered a more diverse and considerably richer assemblage (richness ratios, 4·97 vs ≤ 1·16 for PES vs the others). Rank abundance distribution analysis showed that distribution tails were longer (>4 times) in PES, but these did not differ between the remaining and PA. Community comparison showed that PES exhibited a lower variation across trials than the PA, while the remaining did not. CONCLUSIONS: PES filter markedly outperformed the other filters in quantitative and qualitative recovery of AM. SIGNIFICANCE AND IMPACT OF THE STUDY: Our findings demonstrated the importance of filter selection for sampling AM.


Assuntos
Aerossóis/isolamento & purificação , Microbiologia do Ar , Filtração/instrumentação , Microbiota , Bactérias/classificação , Bactérias/isolamento & purificação , Eucariotos/classificação , Eucariotos/isolamento & purificação , Fungos/classificação , Fungos/isolamento & purificação , Manejo de Espécimes
7.
Am J Infect Control ; 49(2): 274-275, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32682016

RESUMO

The use of surgical sterilization wrap for respirator masks during the COVID-19 crisis has become a popularized personal protective equipment alternative option due to claims supporting its ability to meet N95 standards. This study sought to assess these claims using standardized filter testing. The tested material failed to meet N95 standards and suggests its use may place medical personnel at increased risk of harm when managing COVID-19 patients.


Assuntos
COVID-19/prevenção & controle , Desenho de Equipamento/efeitos adversos , Máscaras/virologia , Teste de Materiais/estatística & dados numéricos , Dispositivos de Proteção Respiratória/virologia , SARS-CoV-2/isolamento & purificação , Aerossóis/isolamento & purificação , COVID-19/virologia , Desenho de Equipamento/normas , Pessoal de Saúde , Humanos , Máscaras/normas , Dispositivos de Proteção Respiratória/normas , Esterilização
9.
Emerg Infect Dis ; 26(9)2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32568661

RESUMO

We aerosolized severe acute respiratory syndrome coronavirus 2 and determined that its dynamic aerosol efficiency surpassed those of severe acute respiratory syndrome coronavirus and Middle East respiratory syndrome. Although we performed experiment only once across several laboratories, our findings suggest retained infectivity and virion integrity for up to 16 hours in respirable-sized aerosols.


Assuntos
Aerossóis/isolamento & purificação , Betacoronavirus/isolamento & purificação , Infecções por Coronavirus/transmissão , Transmissão de Doença Infecciosa , Pneumonia Viral/transmissão , Suspensões/isolamento & purificação , COVID-19 , Infecções por Coronavirus/virologia , Humanos , Coronavírus da Síndrome Respiratória do Oriente Médio/isolamento & purificação , Pandemias , Pneumonia Viral/virologia , SARS-CoV-2
10.
Nat Med ; 26(5): 676-680, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32371934

RESUMO

We identified seasonal human coronaviruses, influenza viruses and rhinoviruses in exhaled breath and coughs of children and adults with acute respiratory illness. Surgical face masks significantly reduced detection of influenza virus RNA in respiratory droplets and coronavirus RNA in aerosols, with a trend toward reduced detection of coronavirus RNA in respiratory droplets. Our results indicate that surgical face masks could prevent transmission of human coronaviruses and influenza viruses from symptomatic individuals.


Assuntos
Infecções por Coronavirus/transmissão , Máscaras/virologia , Pneumonia Viral/transmissão , Infecções Respiratórias/transmissão , Aerossóis/isolamento & purificação , COVID-19 , Infecções por Coronavirus/prevenção & controle , Infecções por Coronavirus/virologia , Expiração/fisiologia , Humanos , Orthomyxoviridae/isolamento & purificação , Orthomyxoviridae/patogenicidade , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Pneumonia Viral/virologia , RNA Viral/isolamento & purificação , Infecções Respiratórias/patologia , Infecções Respiratórias/virologia , Eliminação de Partículas Virais
11.
Artigo em Inglês | MEDLINE | ID: mdl-31861409

RESUMO

Indoor air quality (IAQ) in household environments is mandatory since people spend most of their time in indoor environments. In order to guarantee a healthy environment, air purification devices are often employed. In the present work, a commercial household vacuum cleaner has been tested in order to verify its efficiency in reducing the mass concentration and particle number of aerosol particulate matter (PM). The efficiency has been tested measuring, while the instrument was working, PM10 (particles with aerodynamic diameter less than 10 µm), PM2.5 (particles with aerodynamic diameter less than 2.5 µm), PM1 (particles with aerodynamic diameter less than 1 µm), and 7 size-fractions in the range between 0.3 and >10 µm. Measurements have been carried out by means of a portable optical particle counter instrument and simulating the working conditions typical of a household environment. It has been found that the tested commercial device significantly reduces both PM concentrations and particle number, especially in the finest fraction, i.e., particles in the range 0.3-0.5 µm, allowing an improvement of indoor air quality.


Assuntos
Aerossóis/isolamento & purificação , Poluição do Ar em Ambientes Fechados/análise , Material Particulado/análise , Ar Condicionado , Monitoramento Ambiental , Humanos , Tamanho da Partícula
12.
Artigo em Inglês | MEDLINE | ID: mdl-31698807

RESUMO

Concentrations of atmospheric culturable bioaerosols at mountain and seashore sites were measured in field investigations by using a bio-culture sampler. The eastern Korean peninsula was selected for the measurements because of the short distance between the mountain site and the seashore site. Detectable concentrations of culturable fungal and bacterial bioaerosols (maximum 1065 CFU/m3) were quantitatively measured at the mountain and seashore sites. In addition, measurement of bioaerosols was conducted at an urban area as reference data. Significantly higher concentrations of bioaerosols were found at the mountain site. However, several fold smaller levels of bioaerosols were detected at the seashore site (t-test p-value < 0.05).


Assuntos
Aerossóis/isolamento & purificação , Microbiologia do Ar , Altitude , Bactérias/isolamento & purificação , Monitoramento Ambiental/métodos , Fungos/isolamento & purificação , Oceanos e Mares , Cidades , Humanos , República da Coreia
13.
Talanta ; 194: 233-242, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30609525

RESUMO

The majority of atmospheric compounds measured in ice cores are inorganic, while analysis of their organic counterparts is a less well developed field. In recent years, understanding of formation, transport pathways and preservation of these compounds in ice and snow has improved, showing great potential for their use as biomarkers in ice cores. This study presents an optimised analytical technique for quantification of terrestrial and marine biosphere emissions of secondary organic aerosol (SOA) components and fatty acids in ice using HPLC-MS analysis. Concentrations of organic compounds in snow and ice are extremely low (typically ppb or ppt levels) and thus pre-concentration is required prior to analysis. Stir bar sorptive extraction (SBSE) showed potential for fatty acid compounds, but failed to recover SOA compounds. Solid phase extraction (SPE) recovered compounds across both organic groups but methods improving some recoveries came at the expense of others, and background contamination of fatty acids was high. Rotary evaporation was by far the best performing method across both SOA and fatty acid compounds, with average recoveries of 80%. The optimised preconcentration - HPLC-MS method achieved repeatability of 9% averaged for all compounds. In environmental samples, both concentrations and seasonal trends were observed to be reproducible when analysed in two different laboratories using the same method.


Assuntos
Aerossóis/análise , Organismos Aquáticos/química , Cromatografia Líquida/métodos , Ácidos Graxos/análise , Gelo , Espectrometria de Massas em Tandem/métodos , Aerossóis/isolamento & purificação , Biomarcadores/análise , Calibragem , Ácidos Graxos/isolamento & purificação , Reprodutibilidade dos Testes , Extração em Fase Sólida , Volatilização
14.
Anal Chim Acta ; 1038: 67-78, 2018 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-30278909

RESUMO

Currently, there is lack of standardized conditions for the collection and analysis of e-cigarette (EC) aerosol. Considering the urgent need for the development of these guidelines, a procedure for EC aerosol analysis was developed. A novel automatic e-cigarette aerosol generator was designed. For the first time, melt-blown non-woven fabric was applied for the effective uptake of compounds released from vaporized e-liquid. The extraction procedure was optimized in terms of type of extraction solvent, amount of sorbent and solvent volume. For optimization, a model e-liquid containing flavour additives belonging to various chemicals group with various chemical properties was investigated. The aerosol trapping efficiency was satisfactory and was equal to 92 ±â€¯7%. Final determination was performed by GC-MS/MS. Quantitation was based on the mass change tracking approach (MCT), which assumes the monitoring of e-liquid mass changes before and after vaping. The combination of non-woven fabric and sampling approach (MCT) was proven to be effective in acquisition of reliable data. Thus, the concentrations in aerosol and emission factors were calculated for aerosols collected during the vaping of both model e-liquids and real samples. Validation was performed by evaluating key analytical parameters, such as linearity, accuracy, precision, limit of detection (LOD) and quantitation (LOQ). For all investigated compounds, recoveries from 70% to 118% together with precision and reproducibility below 12% were achieved. The applicability of the described approach was examined by analysing EC refill solutions commercially available on the Polish market.


Assuntos
Aerossóis/isolamento & purificação , Automação , Sistemas Eletrônicos de Liberação de Nicotina , Vaping , Aerossóis/análise , Sistemas Eletrônicos de Liberação de Nicotina/instrumentação , Polônia
15.
Sci Rep ; 8(1): 7559, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29765089

RESUMO

E-cigarette aerosol emission studies typically focus on benchmarking toxicant levels versus those of cigarettes. However, such studies do not fully account for the distinct chemical makeup of e-liquids and their unique properties. These approaches often conclude that there are fewer and lower levels of toxins produced by e-cigarettes than by cigarettes. In 2015, we reported the discovery of new hemiacetals derived from the reaction of formaldehyde and the e-liquid solvents. The main finding was that they constituted a significant proportion of potentially undetected formaldehyde. Moreover, unlike gaseous formaldehyde, the hemiacetals reside in the aerosol particulate phase, and thus are capable of delivering formaldehyde more deeply into the lungs. However, the findings were criticized by those claiming that some of the results were obtained under conditions that are averse to vapers. A "reinvestigation" of our study was recently published addressing this latter issue. However, this reinvestigation ignored major details, including no mention of the formaldehyde hemiacetals. Herein, we isolated both gaseous formaldehyde and formaldehyde hemiacetals at an intermediate power level claimed, in the "reinvestigation", to be relevant to "non-averse," "normal" usage. The results were that both gaseous formaldehyde and formaldehyde from hemiacetals were produced at levels above OSHA workplace limits.


Assuntos
Acetais/isolamento & purificação , Aerossóis/isolamento & purificação , Formaldeído/isolamento & purificação , Acetais/toxicidade , Aerossóis/toxicidade , Cromatografia Líquida de Alta Pressão , Sistemas Eletrônicos de Liberação de Nicotina , Formaldeído/toxicidade , Espectroscopia de Ressonância Magnética
16.
J Air Waste Manag Assoc ; 67(3): 352-357, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27336801

RESUMO

With increasing attention on sulfuric acid emission, investigations on the removal characteristics of sulfuric acid aerosols by the limestone gypsum wet flue gas desulfurization (WFGD) system and the wet electrostatic precipitator (WESP) were carried out in two coal-fired power plants, and the effects of the WFGD scrubber type and the flue gas characteristics were discussed. The results showed that it was necessary to install the WESP device after desulfurization, as the WFGD system was inefficient to remove sulfuric acid aerosols from the flue gas. The removal efficiency of sulfuric acid aerosols in the WFGD system with double scrubbers ranged from 50% to 65%, which was higher than that with a single scrubber, ranging from 30% to 40%. Furthermore, the removal efficiency of WESP on the sulfuric acid aerosols was from 47.9% to 52.4%. With increased concentrations of SO3 and particles in the flue gas, the removal efficiencies of the WFGD and the WESP on the sulfuric acid aerosols were increased. IMPLICATIONS: Investigations on removal of sulfuric acid aerosols by the WFGD and the WESP in the power plants were aimed at the control of sulfuric acid emission. The results showed that the improvement of the WFGD system was beneficial for the reduction of sulfuric acid emission, while the WESP system was essential to control the final sulfuric acid aerosol concentration.


Assuntos
Aerossóis/isolamento & purificação , Poluentes Ocupacionais do Ar/isolamento & purificação , Carvão Mineral , Centrais Elétricas , Ácidos Sulfúricos/isolamento & purificação , Poluentes Atmosféricos/análise , Gases
20.
Environ Technol ; 37(11): 1315-24, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26583905

RESUMO

The purpose of this study was to determine the properties of fibrous gas filtration media produced from mineral zeolite. Fibres were generated by direct current plasma spray. The paper characterizes morphology, chemical composition, geometrical structure of elementary fibres, and thermal resistance, as well as the filtration properties of fibre media. The diameter of the produced elementary fibres ranged from 0.17 to 0.90 µm and the length ranged from 0.025 to 5.1 mm. The release of fibres from the media in the air stream was noticed, but it was minimized by hot-pressing the formed fibre mats. The fibres kept their properties up to the temperature of 956°C, while further increase in temperature resulted in the filter media becoming shrunk and brittle. The filtration efficiency of the prepared filter mats ranged from 95.34% to 99.99% for aerosol particles ranging in a size between 0.03 and 10.0 µm. Unprocessed fibre media showed the highest filtration efficiency when filtering aerosol particles smaller than 0.1 µm. Hot-pressed filters were characterized by the highest quality factor values, ranging from 0.021 to 0.064 Pa(-1) (average value 0.034 Pa(-1)).


Assuntos
Aerossóis/isolamento & purificação , Poluentes Atmosféricos/isolamento & purificação , Filtração/métodos , Fibras Minerais/análise , Zeolitas/química , Aerossóis/química , Poluentes Atmosféricos/química , Tamanho da Partícula , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA