Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
1.
J Vasc Surg ; 79(6): 1369-1378, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38316346

RESUMO

OBJECTIVE: There are a variety of methods used today to treat common iliac aneurysms with endovascular techniques. Of these approaches, little is known about whether a particular limb strategy influences endoleak, reintervention, or aneurysm regression rates. We present 5-year data comparing endoleak, stent graft migration, fracture, aneurysm sac dynamics, and aortic rupture rates among patients treated with bell bottom limbs (BB), iliac branch endoprosthesis (IBE), and coil and cover (CC) approaches from the Global Registry for Endovascular Aortic Treatment registry. Secondary end points were all-cause mortality, stroke, reintervention, and paraplegia. METHODS: Subjects from the GORE Global Registry for Endovascular Aortic Treatment were enrolled over a 5-year period from October 2017 to August 2022. We included 924 subjects in this study. Statistical data was generated on R software and limb groups were compared using the Pearson's χ2 test and the Kruskal-Wallis rank-sum test. RESULTS: We found no statistical difference in endoleak rates, stent graft migration, fracture, or aortic rupture when stratified by limb strategy. There was no difference between limb approaches with regard to aneurysm sac dynamics among those with abdominal aortic aneurysms and common iliac aneurysms. Similarly, no statistical difference between limb strategies was found in all-cause mortality, stroke, paraplegia, or reintervention rates. Among patients that required an additional graft during reintervention, the highest rates were found within the IBE group 8.6%, compared with BB group 2.2% and CC group 1.3% (P = .006). CONCLUSIONS: Overall, there was no difference among limb strategies in endoleak rates, stent graft migration, aneurysm sac dynamics, aortic rupture rates, or our secondary end points. Increased rates of reintervention requiring an additional graft within the IBE group is noteworthy and must be weighed against the adverse effects of hypogastric sacrifice with the CC approach or potentially less advantageous seal zones in the BB approach. This finding suggests that all limb approaches have equivalent effectiveness in managing the aneurysmal common iliac artery; thus, the choice of limb strategy should be individualized and remain at physician discretion. Future research should include a more robust sample size to reproduce these findings.


Assuntos
Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Desenho de Prótese , Sistema de Registros , Stents , Humanos , Aneurisma Ilíaco/cirurgia , Aneurisma Ilíaco/mortalidade , Aneurisma Ilíaco/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Masculino , Feminino , Resultado do Tratamento , Fatores de Tempo , Idoso , Fatores de Risco , Endoleak/etiologia , Endoleak/cirurgia , Idoso de 80 Anos ou mais , Ruptura Aórtica/cirurgia , Ruptura Aórtica/mortalidade , Ruptura Aórtica/diagnóstico por imagem , Falha de Prótese , Estudos Retrospectivos , Medição de Risco , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Migração de Corpo Estranho/etiologia
2.
J Vasc Surg ; 79(6): 1379-1389, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38280686

RESUMO

OBJECTIVE: Infected native aneurysms (INAs) of the abdominal aorta and iliac arteries are uncommon, but potentially fatal. Endovascular aneurysm repair (EVAR) has recently been introduced as a durable treatment option, with outcomes comparable to those yielded by conventional open repair. However, owing to the rarity of the disease, the strengths and limitations of each treatment remain uncertain. The present study aimed to separately assess post-open repair and post-EVAR outcomes and to clarify factors affecting the short-term and late prognosis after each treatment. METHODS: Using a nationwide clinical registry, we investigated 600 patients treated with open repair and 226 patients treated with EVAR for INAs of the abdominal aorta and/or common iliac artery. The relationships between preoperative or operative factors and postoperative outcomes, including 90-day and 3-year mortality and persistent or recurrent aneurysm-related infection, were examined. RESULTS: Prosthetic grafts were used in >90% of patients treated with open repair, and in situ and extra-anatomic arterial reconstruction was performed in 539 and 57 patients, respectively. Preoperative anemia and imaging findings suggestive of aneurysm-enteric fistula were independently associated with poor outcomes in terms of both 3-year mortality (hazard ratio [HR], 1.62; 95% confidence interval [CI], 1.01-2.62; P = .046, and HR, 2.24; 95% CI, 1.12-4.46; P = .022, respectively) and persistent or recurrent infection (odds ratio [OR], 2.16; 95% CI, 1.04-4.49; P = .039, and OR, 4.96; 95% CI, 1.81-13.55; P = .002, respectively) after open repair, whereas omental wrapping or packing and antibiotic impregnation of the prosthetic graft for in situ reconstruction contributed to improved 3-year survival (HR, 0.60; 95% CI, 0.39-0.92; P = .019, and HR, 0.53; 95% CI, 0.32-0.88; P = .014, respectively). Among patients treated with EVAR, abscess formation adjacent to the aneurysm was significantly associated with the occurrence of persistent or recurrent infection (OR, 2.24; 95% CI, 1.06-4.72; P = .034), whereas an elevated preoperative white blood cell count was predictive of 3-year mortality (HR, 1.77; 95% CI, 1.00-3.13; P = .048). CONCLUSIONS: Profiles of prognostic factors differed between open repair and EVAR in the treatment of INAs of the abdominal aorta and common iliac artery. Open repair may be more suitable than EVAR for patients with concurrent abscess formation.


Assuntos
Aneurisma Infectado , Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Sistema de Registros , Humanos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Procedimentos Endovasculares/instrumentação , Masculino , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Feminino , Idoso , Aneurisma Ilíaco/cirurgia , Aneurisma Ilíaco/mortalidade , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/microbiologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Implante de Prótese Vascular/instrumentação , Aneurisma Infectado/cirurgia , Aneurisma Infectado/microbiologia , Aneurisma Infectado/mortalidade , Aneurisma Infectado/diagnóstico por imagem , Resultado do Tratamento , Fatores de Risco , Fatores de Tempo , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Prótese Vascular/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/diagnóstico , Recidiva , Medição de Risco
3.
Ann Vasc Surg ; 80: 283-292, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34758376

RESUMO

OBJECTIVES: Patient injury claims data and insurance records provide detailed information on patient injuries. This study aimed to identify the errors and adverse events that led to patient injuries in vascular surgery for the treatments of abdominal aortic aneurysms (AAA) and iliac artery aneurysms (IAA) in Finland. The study also assessed the severity and preventability of the injuries. MATERIALS AND METHODS: A retrospective analysis of Finnish Patient Insurance Centre's insurance charts of compensated patient injuries in the treatment of AAA and IAA. Records of all compensated patient injury claims involving AAA and IAA between 2004 and 2017 inclusive were reviewed. Contributing factors to injury were identified and classified. The injuries were assessed for their preventability by using the WHO Surgical Safety Checklist correctly. The degree of harm was graded by Clavien-Dindo classification. RESULTS: Twenty-six patient injury incidents were identified in the treatment of 23 patients. Typical injuries involved delays in diagnosis or treatment, errors in surgical technique or injuries to adjacent anatomic organs. Three (13.0%) patients died due to patient injury. Two deaths were caused by delays in diagnosis of ruptured abdominal aortic aneurysm (RAAA) and the third death was due to missed diagnosis of post-operative myocardial infarction. Retained foreign material caused injuries to two (8.7%) patients. One (4.3%) patient had a severe postoperative infection. Three (13.0%) patients experienced an injury to an adjacent organ. One patient had a bilateral and another a unilateral above-the-knee amputation due to patient injury. Three injuries were considered preventable. Most harms were grade IIIb Clavien-Dindo classification in which injured patients required a surgical intervention under general anesthesia. CONCLUSIONS: Compensated patient injuries involving the treatment of AAA and IAA are rare, but are often serious. Injuries were identified during all stages of care. Most injuries involved open surgical procedures.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma Ilíaco/cirurgia , Complicações Intraoperatórias/epidemiologia , Erros Médicos/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/mortalidade , Ruptura Aórtica/diagnóstico , Ruptura Aórtica/mortalidade , Diagnóstico Tardio , Feminino , Finlândia/epidemiologia , Humanos , Aneurisma Ilíaco/mortalidade , Seguro Saúde , Complicações Intraoperatórias/economia , Masculino , Erros Médicos/economia , Erros Médicos/mortalidade , Pessoa de Meia-Idade , Complicações Pós-Operatórias/economia , Complicações Pós-Operatórias/mortalidade , Sistema de Registros , Estudos Retrospectivos
4.
J Vasc Surg ; 74(4): 1163-1171, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33887426

RESUMO

OBJECTIVE: Marfan syndrome (MFS) affects the cardiovascular system. Aortic root aneurysm is a pathognomonic feature of MFS; however, the abdominal aorta is rarely affected. A consensus on surveillance for the abdominal aorta in patients with MFS has not been established. In the present study, we compared the outcomes after open surgical repair (OSR) of abdominal aortic aneurysms (AAAs) in patients with and without MFS. METHODS: We conducted a retrospective, single-center cohort study from 2003 to 2020. We reviewed and compared 28 patients with MFS and 426 patients without MFS who had undergone OSR for AAAs. The baseline characteristics, medical comorbidities, previous cardiovascular surgery, anatomic features of the AAAs, and surgical treatment outcomes were compared between the two groups. RESULTS: The patients with MFS were younger than those without MFS at the AAA diagnosis (47.2 ± 12.3 vs 70.6 ± 7.9 years; P < .001). The proportion of women was also greater for those with MFS (46.4% vs 15.7%; P < .001). The AAAs were most often located at the infrarenal aorta in both groups. However, thoracoabdominal AAAs were more often found among patients with MFS (10.7% vs 0.9%; P < .012). The proportion of symptomatic patients was lower in the MFS group (3.6% vs 21.6%; P = .022). The maximum median diameter of the AAA at surgery was smaller in the patients with MFS (52 mm vs 58 mm; P = .001). However, concomitant aortic dissection (32.1% vs 3.3%; P < .001) was more prevalent among the patients with MFS. Consequent aneurysmal changes in the iliac artery after AAA repair were more frequent in the patients with MFS (7.1% vs 0%; P = .004). No significant differences were found in 30-day or overall mortality between the patients with and without MFS during a median follow-up period of 71 months (interquartile range, 24.7-121.1 months) and 26.7 months (interquartile range, 7.4-69.5 months), respectively. CONCLUSIONS: The surgical outcomes of OSR for AAAs for patients with MFS were not significantly different from those for patients without MFS in a well-established surveillance program of MFS.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Dissecção Aórtica/cirurgia , Aneurisma Ilíaco/cirurgia , Síndrome de Marfan/complicações , Procedimentos Cirúrgicos Vasculares , Adulto , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/etiologia , Aneurisma da Aorta Abdominal/mortalidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/etiologia , Aneurisma Ilíaco/mortalidade , Masculino , Síndrome de Marfan/diagnóstico , Síndrome de Marfan/mortalidade , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/mortalidade
5.
Br J Surg ; 108(3): 286-295, 2021 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-33793720

RESUMO

BACKGROUND: Primary infected aneurysms of the abdominal aorta and iliac arteries are potentially life-threatening. However, because of the rarity of the disease, its pathogenesis and optimal treatment strategy remain poorly defined. METHODS: A nationwide retrospective cohort study investigated patients who underwent surgical treatment for a primary infected abdominal aortic and/or common iliac artery (CIA) aneurysm between 2011 and 2017 using a Japanese clinical registry. The study evaluated the relationships between preoperative factors and postoperative outcomes including 90-day and 3-year mortality, and persistent or recurrent aneurysm-related infection. Propensity score matching was used to compare survival between patients who underwent in situ prosthetic grafting and those who had endovascular aneurysm repair (EVAR). RESULTS: Some 862 patients were included in the analysis. Preceding infection was identified in 30.2 per cent of the patients. The median duration of postoperative follow-up was 639 days. Cumulative overall survival rates at 30 days, 90 days, 1 year, 3 years and 5 years were 94.0, 89.7, 82.6, 74.9 and 68.5 per cent respectively. Age, preoperative shock and hypoalbuminaemia were independently associated with short-term and late mortality. Compared with open repair, EVAR was more closely associated with persistent or recurrent aneurysm-related infection (odds ratio 2.76, 95 per cent c.i. 1.67 to 4.58; P < 0.001). Propensity score-matched analyses demonstrated no significant differences between EVAR and in situ graft replacement in terms of 3-year all-cause and aorta-related mortality rates (P = 0.093 and P =0.472 respectively). CONCLUSION: In patients undergoing surgical intervention for primary infected abdominal aortic and CIA aneursyms, postoperative survival rates were encouraging. Eradication of infection following EVAR appeared less likely than with open repair, but survival rates were similar in matched patients between EVAR and in situ graft replacement.


Assuntos
Aneurisma Infectado/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma Ilíaco/cirurgia , Fatores Etários , Idoso , Aneurisma Infectado/mortalidade , Aneurisma da Aorta Abdominal/mortalidade , Prótese Vascular , Estudos de Coortes , Procedimentos Endovasculares , Feminino , Seguimentos , Humanos , Hipoalbuminemia/mortalidade , Aneurisma Ilíaco/mortalidade , Japão/epidemiologia , Masculino , Análise por Pareamento , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Choque/mortalidade
6.
J Vasc Surg ; 74(5): 1752-1762.e1, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33617979

RESUMO

OBJECTIVE: Our aim was to systematically review results of endovascular aneurysm repair for isolated common iliac artery aneurysms (CIAA) regarding outcomes and to determine if changes should be made to current diameter threshold recommendations for intervention. METHODS: A comprehensive systematic review was performed according to the PRISMA guidelines. PubMed, Scopus, and the Cochrane Central databases were searched. RESULTS: Twenty-one studies were deemed eligible and provided data for 879 patients and 981 isolated CIAA treated with endovascular repair. The majority of the patients (90.8%) were males. The weighted mean age of the patients was 71.7 years (range, 37-91 years). The weighted mean diameter for the CIAA was 41. mm 1 (range, 15-110 mm) and for ruptured aneurysms 58.4 mm. The overall technical success rate was 97.6%. The perioperative mortality rate was 0.7%. Secondary patency rates were reported in only four studies and varied between 96.7% and 100%. The overall morbidity rate was 14%, ranging from 0% to 25%. Most of the studies did not report long-term or adequate follow-up data. Rupture of an isolated CIAA at <4 cm diameter was extremely low. CONCLUSIONS: Endovascular treatment of isolated CIAA is feasible and safe with a low mortality and excellent technical success rates. Consideration of increasing the diameter threshold for intervention of CIAA to 4 cm should be considered. Studies with longer follow-up and reliable long-term results are needed.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco/cirurgia , Artéria Ilíaca/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Tomada de Decisão Clínica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/mortalidade , Artéria Ilíaca/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
Vasc Endovascular Surg ; 55(3): 254-264, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33353481

RESUMO

OBJECTIVES: The purpose of this paper is to report the different modalities for the treatment of isolated internal iliac artery aneurysms (IIIAA), as well as their outcomes. METHODS: We performed a systematic review of the literature (database searched: PubMed, Web of Science, Scopus, Cochrane Library; last search: April 2020). We included articles reporting on the outcomes for IIIAA interventions comprising at least 5 patients. Studies were included when presenting extractable outcome data regarding intraoperative and/or early results. We performed meta-analyses of proportions for different outcomes, using random effects model. RESULTS: Thirteen non-randomized studies were included (192 patients with 202 IIIAA). IIIAA were symptomatic in the 18.1% (95%CI 9.3-26.9; I2 54.46%, P = .019). Estimated mean IIIAA diameter was 46.28 mm (95%CI 39.72-52.85; I2 88.85%, P < .001). Open repair was performed in 21/202 cases. Endovascular treatments were: embolization (81/181), embolization and hypogastric artery coverage (79/181), hypogastric artery coverage by stent-grafting (15/181), stent-grafting in the hypogastric artery (6/181). Overall estimated technical success (TS) rate was 91.6% (95% CI 86.8-95.5; I2 45.82%, P = .031). TS rate was 94.5% for open surgery (95%CI 85.3-100; I2 0%, P = .907), and 89.7% for endovascular repair (95%CI 83.8-95.6; I2 55.43%, P = .006). Estimated overall 30-day mortality was 3.1% (95%CI 0.8-5.4; I2 0%, P = .969). Mortality rates after open surgery and endovascular repair were 8.2% (95%CI 3.4-19.8; I2 0%, P = .545) and 2.8% (95%CI 0.5-5.1; I2 0%, P = .994), respectively. Estimated mean follow-up was 32.63 months (95%CI 21.74-43.53; I2 94.45%, P < .001). During this timeframe, IIIAA exclusion was preserved in 92.8% of the patients (95%CI 89.3-96.2; I2 0%, P = .797). Buttock claudication occurred in 13.9% of the patients (95%CI 8.7-19.2; I2 0%, P = .622). CONCLUSIONS: IIIAA are frequently large, and symptomatic at presentation. Several treatments are proposed in literature, open and endovascular, both with good results. The endovascular treatment is the preferred method of treatment in literature, since it offers good short- to mid-term results and low early mortality. Buttock claudication after hypogastric artery exclusion is a common complication.


Assuntos
Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Ilíaco/cirurgia , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/mortalidade , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Interact Cardiovasc Thorac Surg ; 32(1): 97-105, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33346345

RESUMO

OBJECTIVES: Although commercial iliac branch devices offer a new and valid endovascular approach to treating iliac aneurysm and effectively preserve antegrade flow of the internal iliac artery, their use may not be suited for all types of challenging anatomy, especially isolated common iliac artery aneurysm. Our custom-made iliac bifurcation device has a unique design and excludes both combined and isolated iliac branch aneurysm. This study validated the efficacy and safety of the custom device by comparing clinical outcomes between groups receiving commercial and custom devices. METHODS: Data of consecutive patients receiving iliac bifurcation device implantation for iliac aneurysm with or without concomitant endovascular repair for abdominal aortic aneurysm from January 2010 to May 2019 were reviewed. RESULTS: Iliac bifurcation device implantation with or without concomitant abdominal aortic aneurysm stent grafting was completed in 46 patients (commercial, n = 35; custom, n = 11). No significant differences were observed regarding postoperative complications, occlusion or endoleak. Comparisons of primary (80.8% vs 85.7%, P = 0.88) and secondary (86.5% vs 85.7%, P = 0.85) patency and freedom from reintervention (88.2% vs 100%, P = 0.33), all-cause mortality (78.6% vs 100%, P = 0.25) and aneurysm-related mortality (100% vs 100%, P = 1.00) also indicated no differences at a 5-year surveillance point. Furthermore, the iliac aneurysms of the groups displayed similar shrinkage 1 year after procedures. CONCLUSIONS: For iliac aneurysm, the novel custom-made iliac bifurcation device is an adaptable design not inferior to commercial devices with regard to postoperative complications, bridge occlusion, endoleak and short-term aneurysm remodelling. It provides an alternative for treatment, particularly when certain anatomic challenges are present. CLINICAL TRIAL REGISTRATION: 2018-07-050BC, 2017-01-023ACF.


Assuntos
Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/instrumentação , Aneurisma Ilíaco/complicações , Aneurisma Ilíaco/cirurgia , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese Vascular/efeitos adversos , Feminino , Seguimentos , Humanos , Aneurisma Ilíaco/mortalidade , Artéria Ilíaca/cirurgia , Estimativa de Kaplan-Meier , Masculino , Complicações Pós-Operatórias/etiologia , Cuidados Pré-Operatórios , Estudos Retrospectivos , Resultado do Tratamento
9.
Ann Vasc Surg ; 73: 361-368, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33359705

RESUMO

BACKGROUND: To investigate the effect of unilateral internal iliac artery (IIA) embolization for endovascular aortic repair (EVAR) on gluteal muscle size. METHODS: We assessed the gluteal muscle size in 111 consecutive patients who underwent elective EVAR with unilateral IIA embolization (n = 31) or without IIA embolization (n = 80) for abdominal aortic and/or iliac artery aneurysm. The cross-sectional area (CSA) of the gluteus maximus (Gmax) and gluteus medius/minimus (Gmed/min) was measured on computed tomography preoperatively, 6 months postoperatively, and final follow-up. Mean changes in the Gmax and Gmed/min CSA were evaluated using a mixed model analysis of variance. RESULTS: In the patients with embolization, both the Gmax and Gmed/min CSA significantly decreased over time on the embolization and nonembolization sides (P < 0.001); however, embolization did not affect the changes in the Gmax CSA (P = 0.64) and Gmed/min CSA (P = 0.99). In the patients with embolization and those without embolization, both the Gmax and Gmed/min CSA significantly decreased over time (P < 0.001); however, embolization did not affect the changes in the Gmax CSA (P = 0.76) and Gmed/min CSA (P = 0.11). CONCLUSIONS: Unilateral IIA embolization was not associated with gluteal muscle atrophy after EVAR. Pre-emptive unilateral IIA embolization for EVAR seems to be an acceptable procedure in terms of maintenance of gluteal muscle size.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Ilíaco/cirurgia , Artéria Ilíaca/cirurgia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Nádegas , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/mortalidade , Artéria Ilíaca/diagnóstico por imagem , Masculino , Tomografia Computadorizada Multidetectores , Atrofia Muscular/diagnóstico por imagem , Atrofia Muscular/etiologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
Ann Vasc Surg ; 71: 370-380, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32890639

RESUMO

BACKGROUND: The aim of this study is to identify preoperative and intraoperative factors associated with in-hospital mortality of intact abdominal aortoiliac aneurysm repair. METHODS: In this observational study, prospectively collected information included demographics, risk factors, comorbidities, aneurysm characteristics (including special aneurysm presentation, i.e., inflammatory, mycotic/infected, aortocaval fistula), investigations, and operative variables. Receiver operating characteristic) curve analysis of the Glasgow aneurysm score (GAS) and the Vascular Study Group of New England (VSGNE) score was performed in the subgroup of bland aneurysms undergoing isolated elective repair. RESULTS: A total of 928 cases with intact aortoiliac aneurysms had an elective (n = 882) or urgent (n = 46) repair, associated with an in-hospital mortality of 1.7% and 8.7%, respectively (P = 0.01). Open repair (n = 514) was a predictor of higher mortality (3.3% vs. 0.5% for endovascular aneurysm repair [EVAR], n = 414, odds ratio [OR] 7.1, P = 0.003), and so was the pre-EVAR era (4.8% vs. 1.3% in the EVAR era, OR 4.0, P = 0.004). Other significant predictors included the presence of abdominal/back pain (7.5% vs. 1.3%, OR = 6.0, P = 0.001), preoperative angiography (7% vs. 1.6%, OR = 4.5, P = 0.01), special aneurysm presentation (10.9% vs. 1.5%, OR = 8.1, P < 0.001), concomitant major procedures (19% vs. 1.7%, OR = 14.0, P < 0.001), serious intraoperative complications (9.1% vs. 1.5%, OR = 6.6, P = 0.001), median number of transfused units of blood intraoperatively (2 and 0 for cases with and without mortality, respectively, P < 0.001), and procedure duration (270 and 150 min for cases with and without mortality, respectively, P < 0.001). Open repair (OR = 4.5, P = 0.05), special aneurysm presentation (OR = 6.58, P = 0.001), and concomitant major procedures (OR = 14.3, P < 0.001) were independent predictors of higher mortality. ROC curve analysis for the GAS (P = 0.87) and VSGNE score (P = 0.10) failed to demonstrate statistical significance in the subgroup of bland aneurysms undergoing isolated elective repair. CONCLUSIONS: Our study has demonstrated independent risk factors for mortality, which should be considered when contemplating aortoiliac aneurysm repair. We failed to externally validate the GAS and VSGNE score.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/mortalidade , Técnicas de Apoio para a Decisão , Procedimentos Endovasculares/mortalidade , Mortalidade Hospitalar , Aneurisma Ilíaco/cirurgia , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Procedimentos Cirúrgicos Eletivos , Emergências , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/mortalidade , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Vascular ; 29(6): 817-821, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32370623

RESUMO

OBJECTIVE: The bell-bottom technique is a widely used technique to treat aortoiliac aneurysms with preservation of the hypogastric arteries. The published data are scarce with conflicting results regarding the evolution. The aim of this study was to compare the outcomes of patients submitted to endovascular abdominal aortic aneurysm repair with standard technique (S-EVAR) versus bell-bottom technique. METHODS: This retrospective cohort study compared the outcomes of standard endovascular aneurysm repair (<16 mm iliac limbs) and bell-bottom technique (≥16 mm iliac limbs) in a tertiary vascular center between 2010 and 2015. The end points of this study were type IB endoleak, reintervention and 30-day mortality. The follow-up protocol included CT scans within 30 days of implantation and 12 months. Duplex ultrasound was performed yearly thereafter. RESULTS: Two hundred and three patients were treated with bell-bottom technique (n = 84, mean age 72.2 ± 8.9) and S-EVAR (n = 119, mean age 72.7 ± 8.4). The overall 30-day mortality was 1.9%, with no significant difference between groups. There was higher prevalence of coronary heart disease in the bell-bottom technique group compared to the S-EVAR group (41.6% vs. 18.4%, p < 0.01). One patient in the S-EVAR group (0.85%) and four patients in the bell-bottom technique (4.6%) developed type IB endoleak. The mean follow-up period was 35.2 ± 30.4 months. By Kaplan-Meier analysis, freedom from type IB endoleak in 80 months was 85.2% in the bell-bottom technique group and 98.7% in the S-EVAR group (p = 0.05). The freedom from reintervention in 80 months was 74.0% in the bell-bottom technique group and 94.1% in the S-EVAR group (p = 0.6). CONCLUSIONS: This study shows lower freedom from type IB endoleak in the bell-bottom group compared to the standard repair group. There is no significant difference in reoperation rate and 30-day mortality.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco/cirurgia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/mortalidade , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento
12.
Vasc Endovascular Surg ; 54(7): 618-624, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32666893

RESUMO

BACKGROUND: Surgical site infections (SSI) are frequently seen after aortoiliac vascular surgery (2%-14%). Deep SSIs are associated with graft infection, sepsis, and mortality. This study evaluates the difference in incidence and nature of SSI following open aortoiliac surgery for aneurysmal disease compared to occlusive arterial disease. METHODS: A retrospective cohort study was conducted, including all consecutive patients who underwent open aortoiliac vascular surgery between January 2005 and December 2016 in the Amphia Hospital, Breda, the Netherlands. Patients were grouped by disease type, either aneurysmal or occlusive arterial disease. Data were gathered, including patient characteristics, potential risk factors, and development of SSI. Surgical site infections were defined in accordance with the criteria of the Centers for Disease Control. RESULTS: Between January 2005 and December 2016, a total of 756 patients underwent open aortoiliac surgery of which 517 had aortoiliac aneurysms and 225 had aortoiliac occlusive disease. The group with occlusive disease was younger, predominantly male, and had more smokers. After exclusion of 228 patients undergoing acute surgery, the SSI rate after elective surgery was 6.2%, with 10 of 301 SSIs in the aneurysmal group (3.0%) and 22 of 213 SSIs in the group with occlusive disease (10.3%, P < .001). Also, infection-related readmission and reintervention were higher after occlusive surgery, 6.6% versus 0.9% (P < .001) and 4.2% versus 0.9% (P = .003), respectively. Staphylococcus aureus was found as the most common pathogen, causing 64% of SSI in occlusive disease versus 10% in aneurysmal disease (P = .005). Logistic regression showed occlusive arterial disease and chronic renal disease were associated with SSI. CONCLUSION: Our study presents evidence for a higher rate of SSI in patients with aortoiliac occlusive disease compared to aortoiliac aneurysmal disease, in part due to inherent use of inguinal incision in patients with occlusive disease. All precautions to prevent SSI should be taken in patients undergoing vascular surgery for arterial occlusive disease.


Assuntos
Aneurisma Aórtico/cirurgia , Arteriopatias Oclusivas/cirurgia , Aneurisma Ilíaco/cirurgia , Infecção da Ferida Cirúrgica/epidemiologia , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Idoso , Aneurisma Aórtico/epidemiologia , Aneurisma Aórtico/mortalidade , Arteriopatias Oclusivas/epidemiologia , Arteriopatias Oclusivas/mortalidade , Feminino , Humanos , Aneurisma Ilíaco/etiologia , Aneurisma Ilíaco/mortalidade , Incidência , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Readmissão do Paciente , Retratamento , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Infecção da Ferida Cirúrgica/diagnóstico , Infecção da Ferida Cirúrgica/mortalidade , Infecção da Ferida Cirúrgica/terapia , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/mortalidade
13.
Eur J Vasc Endovasc Surg ; 60(3): 356-364, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32709466

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the long term results of endovascular aneurysm repair (EVAR) in patients with abdominal aortic aneurysm (AAA) and ectatic common iliac arteries (CIAs). METHODS: In a retrospective analysis of a prospectively collected database in two high volume centres, patients with AAAs undergoing elective standard EVAR were divided into two groups: those with both CIA diameters <18 mm, and those with at least one ectatic iliac artery (CIA ≥ 18 mm). Patients with an intentional external iliac artery landing zone were excluded. Primary outcomes were survival and freedom from re-intervention. Secondary end points were EVAR failure and iliac related endoleak and iliac re-intervention. RESULTS: From 2000 to 2015, 648 patients were included in the study, 277 (43%) had at least one CIA ≥ 18 mm. Pre-operative risk factors were similar between the two groups, with the exception of chronic renal insufficiency (p = .010) and cerebrovascular events (p = .040), which were higher in the ectatic CIA group. At 30 days from primary procedure, there was a higher rate of type Ib endoleak in patients with ectatic iliacs (p = .020). A statistically significant increase in the incidence of late type Ib endoleak in patients with ectatic iliac arteries was confirmed at a mean follow up of 74.8 months (p = .01). The need for iliac related re-intervention was higher in patients with CIAs ≥18 mm (odds ratio 1.94; 95% confidence interval 1.1-3.2). CONCLUSION: Ectatic iliac arteries are considered suitable landing zones for EVAR, although there is an increased risk of secondary interventions in time mainly due to late CIA dilation and secondary type Ib endoleak. Patients receiving EVAR with flared iliac limbs may benefit a more intensive surveillance to avoid late failures.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco/cirurgia , Artéria Ilíaca/cirurgia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Bases de Dados Factuais , Dilatação Patológica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/mortalidade , Artéria Ilíaca/diagnóstico por imagem , Itália , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
14.
J Endovasc Ther ; 27(5): 818-825, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32580623

RESUMO

Purpose: To compare and contrast the midterm outcomes of the E-liac and Zenith (ZBIS) iliac branch devices (IBDs) for the preservation of the internal iliac artery (IIA) in aneurysms involving the iliac bifurcation. Materials and Methods: Between January 2014 and December 2018, 84 consecutive patients (median age 74 years; 76 men) were electively treated with the E-liac (n=44) or ZBIS (n=40) IBDs and were retrospectively analyzed to evaluate the technical success, patency, need for reintervention, and mortality associated with these devices. Results: Technical success was achieved in 95 of 99 implantations (95.9%) without any statistically significant difference between the groups (93.7% vs 98.0%, p=0.114). During the first 30 days, 3 occlusions in the ZBIS group and 1 in the E-liac group were identified. There was 1 perioperative death in the ZBIS group. The median follow-up was 37 months for the ZBIS group and 28 months for the E-liac group (p=0.657). Six patients from the ZBIS group and 7 from the E-liac group were lost to follow-up. Among the remaining, there were 2 further deaths recorded, 1 in each group. Four further reinterventions in the E-liac group and 2 in the ZBIS group were performed during follow-up. The Kaplan-Meier estimates of freedom from reintervention were 87.2% (95% CI 82.6% to 90.2%) for the ZBIS group and at 86.0% (95% CI 83.7% to 89.1%) for the E-liac group (p=0.563); the freedom from occlusion estimates were 89.7% (95% CI 85.8% to 94.5%) and 95.3% (95% CI 92% to 98.7%; p=0.317), respectively. Conclusion: The E-liac and the ZBIS IBDs showed equally high technical success, midterm patency, and low reintervention rates.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Aneurisma Ilíaco/cirurgia , Artéria Ilíaca/cirurgia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/mortalidade , Aneurisma Ilíaco/fisiopatologia , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
15.
J Vasc Surg ; 72(4): 1354-1359, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32417014

RESUMO

OBJECTIVE: The most common endoleak after endovascular aneurysm repair is type II. Although type II endoleaks (TIIEL) are generally considered benign, there are reports that they can lead to aortic rupture. In this study, we reviewed the effect of TIIEL on sac size change to determine if sac expansion owing to a TIIEL could result in the development of a type IA endoleak (TIAEL). METHODS: After internal review board approval, all aortoiliac endovascular aneurysm repairs performed at a single institution between June 2006 and June 2012 were retrospectively reviewed. Patient demographics, comorbidities, aneurysm diameter, graft type, need for reintervention, and complications were collected. Patients with TIIEL diagnosed on follow-up imaging were categorized as those who underwent intervention for their TIIEL and those who did not. Outcomes were tabulated with attention to sac size change, development of TIAEL, rupture, and survival. RESULTS: Six hundred twenty-seven patients underwent aortoiliac stent graft placement at our institution during this time period. Patients with an operative indication other than nonruptured infrarenal abdominal aortic aneurysm and those without preoperative computed tomography angiography or follow-up data available for review were excluded. The total number of patients included was 389 with an average follow-up of 58.8 months (range, 0-194 months). Follow-up imaging diagnosed 124 patients with TIIEL (32%). Patients with TIIEL were significantly older (P < .0001) and more likely to be hypertensive (P < .05) but less likely to be smokers (P = .01). They had a significantly larger sac size increase than patients without TIIEL (9.50 vs -0.78 mm; P < .0001). Those with TIIEL were significantly more likely to develop a TIAEL than patients who did not have TIIEL (14% vs 5%; P = .004), but the rate of rupture was not significantly different (4% vs 2%; P = .33). In those with a TIIEL, the average sac size increase at which TIAEL developed was 13 mm. Patients in the TIIEL group who underwent intervention for their TIIEL survived significantly longer than patients who did not undergo intervention (140 months vs 100 months; P = .004). CONCLUSIONS: Our data suggest that there is an increased incidence of late TIAEL in patients with TIIEL compared with those without a TIIEL. Our study also demonstrates an increased overall survival in TIIEL patients who underwent intervention. Future studies are necessary to better define the association between TIIEL with enlarging sac and the development of TIAEL. However, it is reasonable to conclude that intervention for TIIEL should be undertaken at or before a cumulative sac size increase of 13 mm.


Assuntos
Aneurisma Aórtico/cirurgia , Ruptura Aórtica/epidemiologia , Implante de Prótese Vascular/efeitos adversos , Endoleak/epidemiologia , Procedimentos Endovasculares/efeitos adversos , Aneurisma Ilíaco/cirurgia , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/mortalidade , Ruptura Aórtica/etiologia , Implante de Prótese Vascular/instrumentação , Endoleak/diagnóstico , Endoleak/etiologia , Endoleak/cirurgia , Procedimentos Endovasculares/instrumentação , Feminino , Seguimentos , Humanos , Aneurisma Ilíaco/mortalidade , Incidência , Estimativa de Kaplan-Meier , Masculino , Estudos Retrospectivos , Medição de Risco/estatística & dados numéricos , Índice de Gravidade de Doença , Stents/efeitos adversos , Resultado do Tratamento
16.
Eur J Vasc Endovasc Surg ; 60(1): 49-55, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32331994

RESUMO

OBJECTIVE: The new 2019 guideline of the European Society for Vascular Surgery (ESVS) recommends consideration for elective iliac artery aneurysm (eIAA) repair when the iliac diameter exceeds 3.5 cm, as opposed to 3.0 cm previously. The current study assessed diameters at time of eIAA repair and ruptured IAA (rIAA) repair and compared clinical outcomes after open surgical repair (OSR) and endovascular aneurysm repair (EVAR). METHODS: This retrospective observational study used the nationwide Dutch Surgical Aneurysm Audit (DSAA) registry that includes all patients who undergo aorto-iliac aneurysm repair in the Netherlands. All patients who underwent primary IAA repair between 1 January 2014 and 1 January 2018 were included. Diameters at time of eIAA and rIAA repair were compared in a descriptive fashion. The anatomical location of the IAA was not registered in the registry. Patient characteristics and outcomes of OSR and EVAR were compared with appropriate statistical tests. RESULTS: The DSAA registry comprised 974 patients who underwent IAA repair. A total of 851 patients were included after exclusion of patients undergoing revision surgery and patients with missing essential variables. eIAA repair was carried out in 713 patients, rIAA repair in 102, and symptomatic IAA repair in 36. OSR was performed in 205, EVAR in 618, and hybrid repairs and conversions in 28. The median maximum IAA diameter at the time of eIAA and rIAA repair was 43 (IQR 38-50) mm and 68 (IQR 58-85) mm, respectively. Mortality was 1.3% (95% CI 0.7-2.4) after eIAA repair and 25.5% (95% CI 18.0-34.7) after rIAA repair. Mortality was not significantly different between the OSR and EVAR subgroups. Elective OSR was associated with significantly more complications than EVAR (intra-operative: 9.8% vs. 3.6%, post-operative: 34.0% vs. 13.8%, respectively). CONCLUSION: In the Netherlands, most eIAA repairs are performed at diameters larger than recommended by the ESVS guideline. These findings appear to support the recent increase in the threshold diameter for eIAA repair.


Assuntos
Aneurisma Ilíaco/cirurgia , Idoso , Idoso de 80 Anos ou mais , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/mortalidade , Procedimentos Endovasculares/estatística & dados numéricos , Feminino , Fidelidade a Diretrizes/estatística & dados numéricos , Humanos , Aneurisma Ilíaco/epidemiologia , Aneurisma Ilíaco/mortalidade , Aneurisma Ilíaco/patologia , Artéria Ilíaca/patologia , Artéria Ilíaca/cirurgia , Masculino , Países Baixos/epidemiologia , Sistema de Registros , Estudos Retrospectivos , Fatores Sexuais , Resultado do Tratamento
17.
J Endovasc Ther ; 27(2): 316-327, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32066324

RESUMO

Purpose: To evaluate the outcomes of the Gore Excluder Iliac Branch Endoprosthesis (IBE) using division branches of the internal iliac artery (IIA) as distal landing zones. Materials and Methods: Between January 1, 2014, and December 31, 2018, 74 patients (mean age 74±7 years; 72 men) treated for aortoiliac or common iliac artery aneurysms had an IBE deployed with distal landing of the side branch within the main trunk (n=60) of the internal iliac artery (IIA) vs within a division branch (n=25). Thirteen (17%) patients received bilateral IBE implantations for a total of 85 vessels evaluated. Early endpoints were technical success, 30-day mortality, 30-day major adverse events (MAEs), and 30-day major access complications. Late endpoints were survival, primary and secondary IIA patency, freedom from IIA branch instability, freedom from new-onset buttock claudication, and aneurysm sac diameter changes. Time-dependent outcomes were reported as Kaplan-Meier curves with differences assessed using the log-rank test. Estimates are presented with the 95% confidence interval (CI). Results: The overall technical success rate was 97%, with 1 technical failure per group (p=0.43). Two patients, one from each group, died within 30 days (p=0.43). No significant differences were seen in the rates of 30-day MAEs (7% vs 17%, p=0.35) or major access complications (9% vs 11%, p>0.99) for patients receiving distal landing in the main trunk vs a division branch, respectively. The mean follow-up for the entire cohort was 19±12 months. The overall 1-year survival rate was 94% (95% CI 74% to 99%). The primary and secondary patency rates at 1 year were 98% (95% CI 88% to 99%) vs 95% (95% CI 72% to 99%, p=0.72) and 98% (95% CI 88% to 99%) vs 100% (p=0.41) for the main trunk vs division branch groups, respectively. Freedom from IIA branch instability estimates were also similar at 1-year follow-up [93% (95% CI 82% to 97%) vs 90% (95% CI 66% to 97%), p=0.29], as were the freedom from new-onset buttock claudication estimates [98% (95% CI 86% to 99%) and 94% (95% CI 67% to 99%), respectively; p=0.62]. Mean sac diameter change was 5.4±5.3 mm, not significantly different between the groups (p=0.85). Conclusion: Use of the posterior or anterior division of the IIA as a distal landing zone for the Gore Excluder IBE was safe and efficacious in the midterm. This technique may permit extending indications for endovascular repair of aortoiliac aneurysms to cases with unsuitable anatomy within the IIA main trunk. Long-term assessment is needed to affirm the efficacy of this technique.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Aneurisma Ilíaco/cirurgia , Artéria Ilíaca/cirurgia , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Aneurisma Aórtico/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/mortalidade , Aneurisma Ilíaco/fisiopatologia , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Masculino , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
18.
Ann Vasc Surg ; 64: 27-32, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31931127

RESUMO

BACKGROUND: The treatment of aortic infections is complex, and the material of reconstruction remains discussed. Several alternatives were suggested in the literature. The current consensus is the use of biological material. The aim of this study was to evaluate the short-term results of bovine pericardium xenografts. METHODS: Between November 2016 and June 2019, we included consecutively all the patients presenting with native aortic infections in which arterial reconstruction was carried out with tubular bovine pericardium grafts sutured longitudinally. We collected the preoperative, peroperative, and postoperative clinical, radiological, biological, and bacteriological characteristics. The recurrence of infection, the graft failures, and the morbimortality were analyzed. RESULTS: Twelve patients including three women were treated. Their mean age was 68.4 ± 9 years. They presented 2 thoracic, 4 thoracoabdominal, 4 abdominal, and 2 aortoiliac aneurysms. The diagnosis was made using angio-CT in all the cases and was confirmed by positron emission tomography (PET) scan in 7 cases and blood cultures in 9 cases. Peroperative cultures were positive in 11 cases. Antibiotics were given in 9 patients before operation for a median duration of 9 (3-19) days and in all the patients postoperatively for a median duration of 42 (1-540) days. The median follow-up was 355 (98-839) days. Six medical complications occurred, including 2 (16.6%) leading to death in the immediate postoperative period. No reoperation was needed. The PET scan returned positive in 1/10 cases (10%) during the follow-up. The diameter of the grafts was preserved, without any defect observed on the angio-CT. CONCLUSIONS: Short-term results showed a mechanical resistance to infection of the bovine pericardium. This biological material offers a promising alternative with multiple advantages including availability, simplicity of preparation, and adaptability to the various locations of the aortic infection.


Assuntos
Aneurisma Infectado/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Bioprótese , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Aneurisma Ilíaco/cirurgia , Pericárdio/transplante , Idoso , Aneurisma Infectado/diagnóstico por imagem , Aneurisma Infectado/microbiologia , Animais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/microbiologia , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/microbiologia , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Bovinos , Feminino , Xenoenxertos , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/microbiologia , Aneurisma Ilíaco/mortalidade , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
19.
J Vasc Surg ; 72(2): 549-555.e1, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31882315

RESUMO

OBJECTIVE: The objective of this study was to evaluate long-term results of self-expanding vs balloon-expandable hypogastric stent grafts in conjunction with iliac branch devices (IBDs) for aortoiliac aneurysm repair in a multicenter experience (pErformance of iLiac branch deVIces for aneurysmS involving the iliac bifurcation [pELVIS] Registry). METHODS: All patients electively treated for aortoiliac aneurysm with the Cook IBD (Cook Medical, Bloomington, Ind) in nine European centers were reviewed. Clinical and imaging data were prospectively collected in each center, and a multicenter database was created and interrogated. The primary outcome was the primary patency of the IBDs. For the purpose of this investigation, three subgroups were identified: patients receiving a hypogastric balloon-expandable stent graft (BESg); those with a self-expanding stent graft (SESg); and those with any stent graft plus relining with a bare-metal stent (RESg). RESULTS: Between 2005 and 2017, there were 691 patients who underwent 747 elective endovascular repairs of aortoiliac aneurysms (n = 518 [75.0%]) or isolated iliac aneurysms (n = 173 [25.0%]) with Cook IBDs (n = 56 bilateral) in nine European centers. Mean age was 72 years (range, 41-93 years); 658 (95.2%) patients were male. In 364 patients (52.7%), BESg was used; in 127 (18.4%), SESg; and in 200 (28.9%), RESg. At 30 days, there were 3 (0.4%) perioperative deaths, 3 (0.4%) technical failures, 7 (1.0%) graft thromboses, 30 (4.3%) reinterventions, and 1 (0.1%) conversion to open repair. After a mean follow-up of 32 months (range, 0-128 months), 28 (3.7%) IBD occlusions and 17 (2.3%) IBD-related endoleaks occurred. In 10 patients, iliac diameter increased >5 mm (1.4%). Overall primary patency was 99.2% at 1 month, 97.9% at 12 months, and 95.1% at 72 months. Primary patency was not significantly different in the BESg vs SESg or RESg cohorts (P = .4). During follow-up, there were 126 (18.2%) reinterventions, 93 (13.5%) of which were IBD related, including 11 (1.6%) conversions. Overall, freedom from reintervention and conversion was 90.4% at 12 months and 71.0% at 72 months. IBD-related reinterventions during follow-up in the three cohorts were not significantly different (P = .3) Overall survival was 71.3% at 72 months without differences between the subgroups. At multivariate analysis, aneurysmal hypogastric artery (P < .001; Exp [B] = 4.44) and bilateral treatment (P = .02; Exp [B] = 1.87) were associated with an increase in late failure. CONCLUSIONS: In this wide real-world experience, long-term results of endovascular treatment of aortoiliac aneurysms with the IBD are favorable, with a low rate of late graft occlusion and aneurysm-related death. No significant differences in clinical outcomes were observed in patients receiving hypogastric BESg vs SESg or endovascular relining.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Aneurisma Ilíaco/cirurgia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Europa (Continente) , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/mortalidade , Aneurisma Ilíaco/fisiopatologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
20.
Ann Vasc Surg ; 62: 35-44, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31201971

RESUMO

BACKGROUND: Iliac branch devices (IBDs) can treat iliac and aortoiliac aneurysms (AIAs) less invasively than open surgery (OS) and preserve pelvic perfusion. Our hypothesis was that the rates of perioperative complications after treatment for AIAs are similar between IBDs and hypogastric occlusion with coil and cover (C&C), and lower than OS. METHODS: We identified patients undergoing elective AIA repair by IBD, C&C, and OS (all with infrarenal clamps) within the National Surgical Quality Improvement Program (NSQIP) vascular aneurysm specific Participant User Files (2012-2016). Baseline characteristics, procedural variables, and 30-day outcomes were compared. The primary outcomes were any major complication or death. Secondary outcomes included minor complications, total operative time, total and intensive care unit length of stay (LOS), and reinterventions. Multivariable logistic regression assessed differences in major complications between IBD and C&C/OS after adjusting for patient and procedural variables. RESULTS: We identified 593 patients (83% men, mean age 71.6 ± 9 years) undergoing elective AIA repair (IBD = 283, C&C = 118, and OS = 192). Patient age and American Society of Anesthesiology (ASA) classification varied significantly between groups. Mean aneurysm diameter was higher for OS and similar between IBD and C&C (5.9 cm vs. 5.5 cm and 5.2 cm, respectively, P < 0.001). OS was associated with higher rate of major complications (65.5% vs. IBD: 8.8% and C&C: 13.6%, P=<0.001) and higher mortality (3.6% vs. IBD: 0.7% and C&C: 0%, P = 0.017). Minor complications and reinterventions were similar. IBD patients had significantly shorter total operative time and total and intensive care unit LOS. After adjustment, OS was associated with higher major complications compared with IBD (Odds ratio [OR]: 11.3, 95% confidence interval [CI]: 5.8-21.9, P < 0.001), primarily because of the use of transfusions (major complications excluding transfusions OR: 1.3, 95% CI: 0.6-2.8, P = 0.52). Major complications between IBD and C&C were similar (OR: 1.6, 95% CI: 0.8-3.4, P = 0.23). CONCLUSIONS: The use of IBDs for elective treatment of AIAs is associated with favorable perioperative outcomes and a lower rate of major complications compared with OS, primarily because of fewer transfusions. IBDs use has perioperative outcomes similar to C&C with the associated benefit of preserving pelvic perfusion. Pending long-term durability results for this technique, IBDs appear to be associated with several perioperative advantages in patients with AIAs compared with OS and C&C.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Aneurisma Ilíaco/cirurgia , Pelve/irrigação sanguínea , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Bases de Dados Factuais , Procedimentos Cirúrgicos Eletivos , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/instrumentação , Embolização Terapêutica/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/mortalidade , Aneurisma Ilíaco/fisiopatologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA