Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 496
Filtrar
1.
Adv Exp Med Biol ; 1441: 909-914, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38884759

RESUMO

Ebstein anomaly (EA) is a rare, congenital cardiac defect of the tricuspid valve with a birth prevalence between 0.5 and 1 in 20,000 [1]. It is characterized by displacement of the tricuspid valve toward the apex of the right ventricle (RV) and "atrialization" of the RV (Fig. 57.1) [2]. EA accounts for about 0.5% of all congenital heart diseases (CHD) [2]. Depending on severity of the defect and due to heterogeneity of the disease, patient's presentation varies from severe heart failure symptoms and arrhythmia in neonatal life to asymptomatic adults.


Assuntos
Anomalia de Ebstein , Valva Tricúspide , Anomalia de Ebstein/genética , Anomalia de Ebstein/fisiopatologia , Anomalia de Ebstein/diagnóstico por imagem , Humanos , Valva Tricúspide/anormalidades , Valva Tricúspide/fisiopatologia , Predisposição Genética para Doença , Mutação
2.
Adv Exp Med Biol ; 1441: 903-907, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38884758

RESUMO

Ebstein anomaly is a rare congenital heart defect, accounting for less than 1% of cardiac malformations and occurring in approximately 1 out of 210,000 live births. It is characterized by an abnormality of the tricuspid valve, where the valve is positioned lower than normal in the right ventricle. Although primarily a tricuspid valve defect, the right ventricle itself is often structurally abnormal and weakened (myopathic).


Assuntos
Anomalia de Ebstein , Valva Tricúspide , Anomalia de Ebstein/diagnóstico por imagem , Anomalia de Ebstein/terapia , Anomalia de Ebstein/fisiopatologia , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/anormalidades , Valva Tricúspide/fisiopatologia , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/patologia
3.
Arch Gynecol Obstet ; 310(3): 1491-1497, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38683395

RESUMO

PURPOSE: Ebstein anomaly (EA) and tricuspid valve dysplasia (TVD) represent uncommon congenital malformations of the tricuspid valve. The purpose of this study is to report on current perinatal outcomes of EA/TVD in our center and to investigate clinical and fetal echocardiographic predictors of perinatal mortality. METHODS AND RESULTS: We performed a retrospective study among fetuses diagnosed from January 2014 to December 2023. Clinical and echocardiographic data were obtained from hospital records of Research and Education Hospital. The primary outcome was perinatal mortality. Of 21 fetuses diagnosed, there were 1 lost to follow-up, 1 termination, and 7 demises. In the live-born cohort of 12 live-born patients, 2 died before discharge, yielding an overall perinatal mortality of 50%. The median gestational age at diagnosis was 23 for non-survivors and 24 weeks for survivors. Birth weight was lower in non-survivors (2430 g vs 2990 g). Tricuspid insufficiency severity varied insignificantly. Non-survivors exhibited higher rates of hydrops, functional atresia, and absent antegrade flow (p < 0.05). Two infants with severe tricuspid insufficiency and congenital abnormalities died postnatally. The limited dataset enables further analysis for a predictive model. Notably, all non-survivors displayed hydrops, functional atresia, and absent antegrade flow, hindering definitive determination of the most impactful parameter on survival estimation. CONCLUSION: Perinatal mortality remains notably elevated in fetuses with EA/TVD. The individuals at the highest risk are those with antegrade flow loss and functional atresia of pulmonary valve, this high-risk subgroup could benefit from targeted interventions, such as novel prenatal therapies or a more comprehensive perinatal approach involving optimized timing of delivery and postnatal interventional strategies.


Assuntos
Anomalia de Ebstein , Ecocardiografia , Mortalidade Perinatal , Valva Tricúspide , Ultrassonografia Pré-Natal , Humanos , Anomalia de Ebstein/diagnóstico por imagem , Anomalia de Ebstein/mortalidade , Anomalia de Ebstein/diagnóstico , Feminino , Gravidez , Estudos Retrospectivos , Recém-Nascido , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/anormalidades , Adulto , Idade Gestacional , Diagnóstico Pré-Natal , Masculino , Insuficiência da Valva Tricúspide/diagnóstico por imagem
6.
J Clin Ultrasound ; 52(6): 717-722, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38655706

RESUMO

PURPOSE: To analyze the influence of RV dysfunction evaluated by Free-angle M-mode (FAM) TAPSE Z-score on retrograde ductus arteriosus flow (RDAF) in fetuses with Ebstein anomaly (EA). METHODS: A retrospective cohort study of 30 EA and 60 normal fetuses were enrolled. The EA group was divided into two groups: with RDAF (EA-RDAF group) and without RDAF (EA-NRDAF group). FAM was used to measure TAPSE of EA and normal fetuses, and Z-scores were calculated. The differences of FAM-TAPSE Z-score, gestational week (GW), maternal age (MA), and mitral valve-tricuspid valve distance (MTD) between three groups were compared. The correlation and binary logistic regression between FAM-TAPSE Z-score, GW, MA, MTD, and RDAF were analyzed. RESULTS: FAM-TAPSE Z-score was significantly lower in EA-RDAF group compared to other groups (p < 0.05). FAM-TAPSE Z-score, GW, and MA were negatively correlated with RDAF (p < 0.05), but no correlation was found between TR, MDT, and RDAF (p > 0.05). Multivariate logistic regression showed that FAM-TAPSE Z-score was an independent influencing factor for RDAF (OR = 0.102, p < 0.05). CONCLUSION: RV dysfunction is an independent factor leading to RDAF in EA fetus, which provides a feasible theoretical basis for further study on improvement of RV function through intrauterine treatment to delay and prevent the RDAF, to avoid death cycle and improve live-birth rate.


Assuntos
Anomalia de Ebstein , Valva Tricúspide , Ultrassonografia Pré-Natal , Humanos , Anomalia de Ebstein/fisiopatologia , Anomalia de Ebstein/diagnóstico por imagem , Feminino , Estudos Retrospectivos , Gravidez , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Valva Tricúspide/embriologia , Ultrassonografia Pré-Natal/métodos , Adulto , Canal Arterial/diagnóstico por imagem , Canal Arterial/fisiopatologia , Função Ventricular Direita/fisiologia , Coração Fetal/diagnóstico por imagem , Coração Fetal/fisiopatologia , Estudos de Coortes , Sístole , Ecocardiografia/métodos
7.
Eur J Clin Invest ; 54(8): e14200, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38558254

RESUMO

BACKGROUND: Due to medical and surgical advancements, the population of adult patients with congenital heart disease (ACHD) is growing. Despite successful therapy, ACHD patients face structural sequalae, placing them at increased risk for heart failure and arrhythmias. Left and right ventricular function are important predictors for adverse clinical outcomes. In acquired heart disease it has been shown that echocardiographic deformation imaging is of superior prognostic value as compared to conventional parameters as ejection fraction. However, in adult congenital heart disease, the clinical significance of deformation imaging has not been systematically assessed and remains unclear. METHODS: According to the Preferred Reporting Items for Systematic Reviews checklist, this systematic review included studies that reported on the prognostic value of echocardiographic left and/or right ventricular strain by 2-dimensional speckle tracking for hard clinical end-points (death, heart failure hospitalization, arrhythmias) in the most frequent forms of adult congenital heart disease. RESULTS: In total, 19 contemporary studies were included. Current data shows that left ventricular and right ventricular global longitudinal strain (GLS) predict heart failure, transplantation, ventricular arrhythmias and mortality in patients with Ebstein's disease and tetralogy of Fallot, and that GLS of the systemic right ventricle predicts heart failure and mortality in patients post atrial switch operation or with a congenitally corrected transposition of the great arteries. CONCLUSIONS: Deformation imaging can potentially impact the clinical decision making in ACHD patients. Further studies are needed to establish disease-specific reference strain values and ranges of impaired strain that would indicate the need for medical or structural intervention.


Assuntos
Ecocardiografia , Cardiopatias Congênitas , Insuficiência Cardíaca , Humanos , Cardiopatias Congênitas/diagnóstico por imagem , Prognóstico , Ecocardiografia/métodos , Adulto , Insuficiência Cardíaca/diagnóstico por imagem , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Anomalia de Ebstein/diagnóstico por imagem , Anomalia de Ebstein/fisiopatologia , Arritmias Cardíacas/diagnóstico por imagem , Transplante de Coração
8.
Echocardiography ; 41(4): e15806, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38549419

RESUMO

3D virtual and physical models from ultrasound scan data allow a 3D spatial view of congenital heart anomalies, interactive discussion among a multidisciplinary team, and improved parental counseling. To the best of our knowledge, this is the first description of 3D physical and virtual models of a fetal Ebstein anomaly.


Assuntos
Anomalia de Ebstein , Cardiopatias Congênitas , Gravidez , Feminino , Humanos , Anomalia de Ebstein/diagnóstico por imagem , Ultrassonografia Pré-Natal
10.
Rev. chil. obstet. ginecol. (En línea) ; 89(1): 48-51, feb. 2024. ilus
Artigo em Espanhol | LILACS | ID: biblio-1559721

RESUMO

La anomalía de Ebstein es una cardiopatía congénita rara y poco frecuente caracterizada por el adosamiento de los velos valvulares tricuspídeos; en la etapa prenatal se estima que su incidencia corresponde a un 3% de todas las cardiopatías diagnosticadas. Se presenta el caso de un feto con diagnóstico de anomalía de Ebstein a quien se le realizó un diagnóstico prenatal adecuado, lo que permitió planificar el nacimiento neonatal con un equipo multidisciplinario integral. Debido a la rareza del diagnóstico prenatal de esta entidad, se describe el caso clínico y los hallazgos imagenológicos representativos.


Ebsteins anomaly is a rare and infrequent congenital heart disease characterized by the attachment of the tricuspid valve leaflets; in the prenatal stage it is estimated that its incidence corresponds to 3% of all diagnosed heart diseases. We present the case of a fetus diagnosed with Ebsteins anomaly who underwent an adequate prenatal diagnosis, which made it possible to plan the neonatal birth with a comprehensive multidisciplinary team. Due to the rarity of the prenatal diagnosis of this entity, the clinical case and the representative imaging findings are described.


Assuntos
Humanos , Feminino , Adolescente , Anomalia de Ebstein/diagnóstico por imagem , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico por imagem , Prognóstico , Medição de Risco
11.
J Interv Card Electrophysiol ; 67(4): 887-900, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38289561

RESUMO

Ebstein's anomaly of the tricuspid valve (EA) is an uncommon congenital cardiac malformation. It can present with atrioventricular tachycardia (AVRT), atrioventricular nodal re-entrant tachycardia (AVNRT), atrial arrhythmias, and rarely with ventricular tachycardia. The 12-lead electrocardiogram (ECG) is critically important and often diagnostic even prior to an electrophysiology study (EPS). Due to its complex anatomy, it poses particular challenges for mapping and ablation, even for an experienced electrophysiologist. In this review, we aim to provide insight into the electrophysiological perspective of EA and an in-depth analysis of the various arrhythmias encountered in diverse clinical scenarios.


Assuntos
Anomalia de Ebstein , Eletrocardiografia , Anomalia de Ebstein/cirurgia , Anomalia de Ebstein/fisiopatologia , Anomalia de Ebstein/diagnóstico por imagem , Humanos , Eletrocardiografia/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Ablação por Cateter/métodos , Feminino , Masculino , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico
12.
Heart ; 110(4): 235-244, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37487694

RESUMO

Although survival has significantly improved in the last four decades, the diagnosis of Ebstein's anomaly is still associated with a 20-fold increased risk of mortality, which generally drops after neonatal period and increases subtly thereafter. With increasing age of presentation, appropriate timing of intervention is challenged by a wide spectrum of disease and paucity of data on patient-tailored interventional strategies. The present review sought to shed light on the wide grey zone of post-neonatal Ebstein's manifestations, highlighting current gaps and achievements in knowledge for adequate risk assessment and appropriate therapeutic strategy.A 'wait-and-see' approach has been adopted in many circumstances, though its efficacy is now questioned by the awareness that Ebstein's anomaly is not a benign disease, even when asymptomatic. Moreover, older age at intervention showed a negative impact on post-surgical outcome.In order to tackle the extreme heterogeneity of Ebstein's anomaly, this review displays the multimodality imaging assessment necessary for a proper anatomical classification and the multidisciplinary approach needed for a comprehensive risk stratification and monitoring strategy. Currently available predictors of clinical outcome are summarised for both operated and unoperated patients, with the aim of supporting the decisional process on the choice of appropriate therapy and optimal timing for intervention.


Assuntos
Anomalia de Ebstein , Recém-Nascido , Criança , Adulto , Humanos , Anomalia de Ebstein/diagnóstico por imagem , Anomalia de Ebstein/cirurgia , Medição de Risco , Imagem Multimodal
15.
Pediatr Cardiol ; 45(1): 24-31, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38012401

RESUMO

Detailed three-dimensional cardiac segmentations using cardiac computed tomography (CT) data is technically feasible in patients with Ebstein anomaly, but its complementary role has not been evaluated. This single-center, retrospective study was aimed to evaluate the complementary role of cardiac CT ventricular volumetry in evaluating the severity of Ebstein anomaly. Preoperative cardiac CT ventricular volumetry was performed in 21 children with Ebstein anomaly. CT-based ventricular functional measures were compared between Carpentier types, and between definitive surgical repair types. The Celermajer severity index measured with echocardiography was correlated with CT-based functional parameters. Total right ventricle (RV) and functional RV (fRV) volumes, fRV fraction, fRV/left ventricle (LV) volume ratio, and end-diastolic CT severity index demonstrated statistically significant differences between Carpentier type A/B and Carpentier type C/D (p < 0.05). The Celermajer severity index measured with echocardiography showed a high positive correlation with the end-diastolic CT severity index (R = 0.720, p < 0.002). There were no statistically significant differences in both echocardiography- and CT-based functional measures between patients with biventricular repair and patients with one-and-a-half or univentricular repair (p > 0.05). Compared with echocardiography, cardiac CT ventricular volumetry can provide the severity of Ebstein anomaly objectively and may be used in select patients when echocardiographic results are inconclusive or inconsistent.


Assuntos
Anomalia de Ebstein , Criança , Humanos , Anomalia de Ebstein/diagnóstico por imagem , Anomalia de Ebstein/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Estudos Retrospectivos , Ecocardiografia/métodos , Imagem Cinética por Ressonância Magnética/métodos
16.
J Cardiovasc Magn Reson ; 25(1): 75, 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38057914

RESUMO

BACKGROUND: Due to the heterogeneity of anatomic anomalies in Ebstein's anomaly (EA), particularly in the subset of patients with atrial septal defect (ASD), hemodynamic changes, which ultimately cause left ventricular (LV) deterioration remain unclear. The current study aimed to investigate the effect of concomitant ASD on LV function using cardiovascular magnetic resonance (CMR) imaging in patients with EA. METHODS: This study included 31 EA patients with ASD, 76 EA patients without ASD, 35 patients with simple ASD and 40 healthy controls. Left/right ventricular (RV, the RV was defined as a summation of the functional RV and atrialized RV in EA patients) volumes and functional parameters, LV strain parameters, and echocardiogram indices were compared among the four groups. Associations between variables were evaluated via Spearman or Pearson correlation analyses. The association between risk factors and LV ejection fraction (EF) was determined via multivariate linear regression analysis. RESULTS: Both EA patients and ASD patients had a higher RV/LV end-diastolic volume (RVEDV/LVEDV) as well as lower LV and RV ejection fractions (LVEF/RVEF) compared to healthy controls (all p < 0.05). Moreover, the EA patients with ASD had a significantly higher RVEDV/LVEDV and a lower LVEF and RVEF than those without ASD (all p < 0.05). Multivariate linear regression analysis revealed that the presence of ASD was independently associated with LVEF (ß = - 0.337, p < 0.001). The RVEDV/LVEDV index was associated with LVEF (r = - 0.361, p < 0.001). Furthermore, the LV longitudinal peak diastolic strain rate (PDSR) was lower in EA patients with ASD than those without ASD, patients with simple ASD, and healthy controls (p < 0.05). CONCLUSION: Concomitant ASD is an important risk factor of LV dysfunction in patients with EA, and diastolic dysfunction is likely the predominate mechanism related to LV dysfunction.


Assuntos
Anomalia de Ebstein , Comunicação Interatrial , Disfunção Ventricular Esquerda , Adulto , Humanos , Função Ventricular Esquerda , Anomalia de Ebstein/complicações , Anomalia de Ebstein/diagnóstico por imagem , Anomalia de Ebstein/patologia , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/complicações , Volume Sistólico , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico por imagem
17.
BMJ Case Rep ; 16(12)2023 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-38160022

RESUMO

Complete trisomy 5 is a rare and lethal abnormality. Mosaic trisomy 5 presents in various phenotypes, ranging from a clinically normal fetus to fetuses presenting uterine growth restriction, congenital heart anomalies, multiple dysmorphic features and psychomotor development abnormalities. Although rare, there are cases of a normal psychomotor development regardless of the associated low fetal growth frequently associated with mosaic trisomy 5. This is the first case report to date of a live fetus with complete trisomy 5 reported in chorionic villus sampling and mosaic trisomy 5 in amniotic fluid with a concomitant Ebstein anomaly. Diagnosis of mosaic trisomy 5 represents a challenge for the clinical team and patients, as the information regarding this syndrome is scarce and based mostly on case reports of liveborns, which may introduce a selection bias when counselling the parents.


Assuntos
Amostra da Vilosidade Coriônica , Anomalia de Ebstein , Feminino , Gravidez , Humanos , Trissomia/diagnóstico , Líquido Amniótico , Anomalia de Ebstein/diagnóstico por imagem , Mosaicismo , Feto
19.
J Matern Fetal Neonatal Med ; 36(2): 2271626, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37904503

RESUMO

OBJECTIVE: Ebstein anomaly (EA) is a cardiac malformation with highly variable presentation and severity with limited perinatal management options. We present incorporation of fetal lung measurements into a multidisciplinary evaluation for counseling and predicting postnatal outcomes in patients with severe EA. METHODS: Five fetuses with severe fetal EA were reviewed. Third trimester sonographic observed/expected total lung area (O/E TLA) and lung to head ratio (O/E LHR), fetal MRI total fetal lung volume ratio (O/E-TFLV), echocardiographic cardio-thoracic ratio (CT ratio), sonographic estimated fetal weight (EFW) by Hadlock formula and presence of hydrops, were used to guide perinatal management. RESULTS: Three of five had appropriate fetal growth, were delivered at term in a cardiac operative suite, and underwent immediate intervention with good neonatal outcomes. Two had severe fetal growth restriction (FGR), CT ratios > 0.8 and O/E LHR and TLA < 25%. One of which delivered prematurely with neonatal demise and one suffered in utero demise at 34 weeks. CONCLUSIONS: FGR, hydrops, increased CT ratio and reduced O/E LHR and TFLV are potential prognosticators of poor outcomes in severe EA, and should be validated in larger cohorts that would allow for a statistical analysis of the predictive utility of these measurements.


Pulmonary hypoplasia is associated with severe morbidityThere are limited prognosticating tools to risk stratify and guide management in cases of severe prenatal Ebstein anomaliesFetal MRI may improve prognostication for fetuses with EA.


Assuntos
Anomalia de Ebstein , Hérnias Diafragmáticas Congênitas , Gravidez , Recém-Nascido , Feminino , Humanos , Anomalia de Ebstein/diagnóstico por imagem , Pulmão , Feto , Edema , Ultrassonografia Pré-Natal , Estudos Retrospectivos , Idade Gestacional
20.
Open Heart ; 10(2)2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37550057

RESUMO

OBJECTIVE: Ebstein's anomaly is a rare congenital cardiac condition and data regarding pregnancy outcomes in this patient group are scarce. We evaluated the maternal and perinatal risks of pregnancy in 81 women with Ebstein's anomaly. METHODS: The Registry of Pregnancy and Cardiac disease is a prospective global registry of pregnancies in women with structural cardiac disease. Pregnancy outcomes in women with Ebstein's anomaly were examined. The primary outcome was the occurrence of a major adverse cardiac event (MACE) defined as maternal mortality, heart failure, arrhythmia, thromboembolic event or endocarditis. Secondary endpoints were obstetric and perinatal outcomes and the influence of pregnancy on tricuspid valve regurgitation as well as right atrial and ventricular dimensions. RESULTS: In the 81 women with Ebstein's anomaly (mean age 29.7±6.1 years, 46.9% nulliparous), MACE occurred in 8 (9.9%) pregnancies, mostly heart failure (n=6). There were no maternal deaths. Prepregnancy signs of heart failure were predictive for MACE. Almost half of the women were delivered by caesarean section (45.7%) and preterm delivery occurred in 24.7%. Neonatal mortality was 2.5% and 4.9% of the infants had congenital heart disease. In the subgroup in which prepregnancy and postpregnancy data were available, there was no difference in tricuspid valve regurgitation grade or right atrial and ventricular dimensions before and after pregnancy. CONCLUSIONS: Most women with Ebstein's anomaly tolerate pregnancy well, but women with prepregnancy signs of heart failure are at higher risk for MACE during pregnancy and should be counselled accordingly.


Assuntos
Fibrilação Atrial , Anomalia de Ebstein , Cardiopatias Congênitas , Insuficiência Cardíaca , Insuficiência da Valva Tricúspide , Recém-Nascido , Lactente , Humanos , Feminino , Gravidez , Adulto Jovem , Adulto , Anomalia de Ebstein/diagnóstico por imagem , Anomalia de Ebstein/complicações , Resultado da Gravidez , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/complicações , Estudos Prospectivos , Cesárea , Fibrilação Atrial/complicações , Estudos Retrospectivos , Cardiopatias Congênitas/complicações , Insuficiência Cardíaca/complicações , Sistema de Registros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA