Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.886
Filtrar
1.
Atherosclerosis ; 392: 117504, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38513436

RESUMO

BACKGROUND AND AIMS: The effects of protein convertase subtilisin/kexin type 9 (PCSK9) inhibitors on endothelial function as assessed by flow-mediated dilation (FMD) in patients with acute myocardial infarction (AMI) are unknown. Therefore, we aimed to investigate the effects of the PCSK9 inhibitor alirocumab added to high-intensity statin on FMD, and its association with coronary atherosclerosis in non-infarct related arteries using intracoronary intravascular ultrasound (IVUS), near-infrared spectroscopy (NIRS), and optical coherence tomography (OCT). METHODS: This was a pre-specified substudy among patients recruited at Bern University Hospital, Switzerland, for the randomized-controlled, double-blind, PACMAN-AMI trial, which compared the effects of biweekly alirocumab 150 mg vs. placebo added to rosuvastatin. Brachial artery FMD was measured at 4 and 52 weeks, and intracoronary imaging at baseline and 52 weeks. RESULTS: 139/173 patients completed the substudy. There was no difference in FMD at 52 weeks in the alirocumab (n = 68, 5.44 ± 2.24%) versus placebo (n = 71, 5.45 ± 2.19%) group (difference = -0.21%, 95% CI -0.77 to 0.35, p = 0.47). FMD improved throughout 52 weeks in both groups similarly (p < 0.001). There was a significant association between 4 weeks FMD and baseline plaque burden (IVUS) (n = 139, slope = -1.00, p = 0.006), but not with lipid pool (NIRS) (n = 139, slope = -7.36, p = 0.32), or fibrous cap thickness (OCT) (n = 81, slope = -1.57, p = 0.62). CONCLUSIONS: Among patients with AMI, the addition of alirocumab did not result in further improvement of FMD as compared to 52 weeks secondary preventative medical therapy including high-intensity statin therapy. FMD was significantly associated with coronary plaque burden at baseline, but not with lipid pool or fibrous cap thickness.


Assuntos
Anticorpos Monoclonais Humanizados , Doença da Artéria Coronariana , Endotélio Vascular , Inibidores de Hidroximetilglutaril-CoA Redutases , Infarto do Miocárdio , Inibidores de PCSK9 , Rosuvastatina Cálcica , Ultrassonografia de Intervenção , Humanos , Masculino , Feminino , Anticorpos Monoclonais Humanizados/uso terapêutico , Anticorpos Monoclonais Humanizados/farmacologia , Pessoa de Meia-Idade , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/complicações , Endotélio Vascular/efeitos dos fármacos , Endotélio Vascular/fisiopatologia , Método Duplo-Cego , Idoso , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Rosuvastatina Cálcica/uso terapêutico , Resultado do Tratamento , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Tomografia de Coerência Óptica , Vasodilatação/efeitos dos fármacos , Quimioterapia Combinada , Espectroscopia de Luz Próxima ao Infravermelho , Placa Aterosclerótica/tratamento farmacológico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/fisiopatologia , Artéria Braquial/efeitos dos fármacos , Artéria Braquial/fisiopatologia , Artéria Braquial/diagnóstico por imagem , Fatores de Tempo , Pró-Proteína Convertase 9
3.
BMC Pulm Med ; 24(1): 77, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38336639

RESUMO

OBJECTIVE: This study aimed to investigate the risk factors for peripheral arteriosclerosis (PAS) and peripheral artery disease (PAD) in chronic obstructive pulmonary disease (COPD) patients and potential ultrasound indicators that could be used to improve detection. METHOD: Outpatients seeking care between January 1, 2017, and December 31, 2020, in The First Affiliated Hospital of China Medical University were prospectively recruited. Subjects were divided into COPD and non-COPD (control) groups, and the COPD group was further divided into PAD and non-PAD subgroup, at the same time, PAS and non-PAS subgroup. Indicators of PAD -ankle-brachial index (ABI), indicators of PAS- pulse wave velocity (PWV), and ultrasound indices -peak systolic blood flow velocity (PSV) and blood flow acceleration velocity (AccV) were compared. RESULT: Sixty-nine (61.6%) of 112 enrolled subjects had COPD. COPD patients had higher age, and blood pressure (BP)lower than controls. Seventeen (24.6%) COPD patients had PAD, the prevalence of PAD increases with the decrease of lung function, and seven (16.3%) non-COPD patients had PAD, however, there was no significant statistical difference between COPD and non-COPD groups. Fifty (72.5%) COPD patients had PAS, and thirty-four (79.1%) non-COPD patients had PAS, however, there was also no significant difference. The PAS subgroup had higher age, body mass index(BMI), body fat percentage(BFP), lower FEV1 and FEV1/FVC, as well as higher levels of right brachial artery and left dorsalis pedis artery AccV. Factors that correlated with ABI were 6MWD, post-bronchodilator FEV1, FEV1/ FVC, and maximal middle expiratory flow between 75% and 25% of FVC. Age, BP, and 6MWD, but not pulmonary function, were associated with brachial-ankle PWV (baPWV). There was a positive correlation between baPWV and radial artery AccV bilaterally. CONCLUSION: Radial artery AccV correlated well with baPWV, which suggests that ultrasound could be used to assess both morphological and functional changes in vessels, may serving as a better method to identify PAS in high-risk COPD patients.


Assuntos
Doença Arterial Periférica , Doença Pulmonar Obstrutiva Crônica , Humanos , Análise de Onda de Pulso , Ultrassom , Artéria Braquial/diagnóstico por imagem , Doença Arterial Periférica/epidemiologia
4.
J Strength Cond Res ; 38(5): 873-880, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38241480

RESUMO

ABSTRACT: Vehrs, PR, Reynolds, S, Allen, J, Barrett, R, Blazzard, C, Burbank, T, Hart, H, Kasper, N, Lacey, R, Lopez, D, and Fellingham, GW. Measurements of arterial occlusion pressure using hand-held devices. J Strength Cond Res 38(5): 873-880, 2024-Arterial occlusion pressure (AOP) of the brachial artery was measured simultaneously using Doppler ultrasound (US), a hand-held Doppler (HHDOP), and a pulse oximeter (PO) in the dominant (DOM) and nondominant (NDOM) arms of males ( n = 21) and females ( n = 23) using continuous (CONT) and incremental (INCR) cuff inflation protocols. A mixed-model analysis of variance revealed significant ( p < 0.05) overall main effects between AOP measured using a CONT (115.7 ± 10.9) or INCR (115.0 ± 11.5) cuff inflation protocol; between AOP measured using US (116.3 ± 11.2), HHDOP (115.4 ± 11.2), and PO (114.4 ± 11.2); and between males (120.7 ± 10.6) and females (110.5 ± 9.4). The small overall difference (1.81 ± 3.3) between US and PO measures of AOP was significant ( p < 0.05), but the differences between US and HHDOP and between HHDOP and PO measures of AOP were not significant. There were no overall differences in AOP between the DOM and NDOM arms. Trial-to-trial variance in US measurements of AOP was not significant when using either cuff inflation protocol but was significant when using HHDOP and PO and a CONT cuff inflation protocol. Bland-Altman plots revealed reasonable limits of agreement for both HHDOP and PO measures of AOP. The small differences in US, HHDOP, and PO measurements of AOP when using CONT or INCR cuff inflation protocols are of minimal practical importance. The choice of cuff inflation protocol is one of personal preference. Hand-held Doppler of PO can be used to assess AOP before using blood flow restriction during exercise.


Assuntos
Artéria Braquial , Ultrassonografia Doppler , Humanos , Masculino , Feminino , Artéria Braquial/fisiologia , Artéria Braquial/diagnóstico por imagem , Adulto , Adulto Jovem , Oximetria/instrumentação
5.
J Hand Surg Eur Vol ; 49(2): 275-277, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37728888

RESUMO

Congenital brachial artery occlusion is rare. We report four patients who presented at birth with absent wrist pulses. We propose management recommendations that include anti-coagulation, duplex ultrasound assessment and fasciotomy surgery as early as is safe and possible.


Assuntos
Síndromes Compartimentais , Antebraço , Recém-Nascido , Humanos , Antebraço/cirurgia , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/cirurgia , Extremidade Superior , Síndromes Compartimentais/diagnóstico por imagem , Síndromes Compartimentais/etiologia , Síndromes Compartimentais/cirurgia , Punho , Fasciotomia/efeitos adversos
6.
Vasc Endovascular Surg ; 58(2): 230-234, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37646258

RESUMO

An otherwise healthy 9-month-old infant was treated for a true aneurysm of the proximal brachial artery. The swelling was first noted at seven months of age. An ultrasound scan showed a 2 cm × 2 cm aneurysm of the left brachial artery at the level of the mid-upper arm. Whole-body magnetic resonance angiography (MRA) confirmed this was a true aneurysm of the brachial artery; there was good distal runoff and no other aneurysms elsewhere. Vasculitis screen was negative. Surgical excision of the aneurysm and reconstruction of the brachial artery was performed with a reversed cephalic vein graft. The patient made an uneventful recovery and was discharged home. We present an overview of the workup report and emphasise that a multi-disciplinary team approach is imperative for assessing and managing this rare condition.


Assuntos
Aneurisma , Artéria Braquial , Lactente , Humanos , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/cirurgia , Resultado do Tratamento , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Braço , Extremidade Superior
7.
Ann Vasc Surg ; 102: 209-215, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37922962

RESUMO

BACKGROUND: This study aimed to assess the safety and efficacy of the transbrachial approach as a single or combined procedure for complex interventions in peripheral artery disease (PAD). METHODS: Between March 2011 and April 2021, 169 patients with PAD underwent endovascular therapy via the transbrachial approach as a single or dual procedure. Univariate and multivariate analyses were performed to evaluate the predictors of adverse events at the brachial puncture site. All demographic, clinical, and perioperative data were acquired from electronic medical records and retrospectively analyzed. RESULTS: Brachial artery access was used alone and in combination in 87 and 82 patients, respectively. Patients in the combined-approach group underwent more intraoperative stent implantations and had more vascular closure devices (VCD). Multivariate logistic regression analysis revealed that hypertension was an independent factor for higher rates of brachial puncture site adverse events (odds ratio, 4.76; 95% confidence interval, 1.33-16.97; P = 0.016). Brachial artery access-site complications occurred in 26 patients, including 6 (23.1%) major and 20 (76.9%) minor entry-site complications. Entry-site complications were observed in 21 (16.8%) and 5 (11.4%) patients assigned to manual compression and VCD groups, respectively. There were no significant intergroup differences in the incidence of major or minor complications. Interestingly, patients assigned to the VCD group did not experience major entry-site complications. CONCLUSIONS: The transbrachial approach, as a single or combined procedure, is a safe alternative to complex interventions in patients with PAD. Complications of brachial access progressively decrease with improved blood pressure control.


Assuntos
Cateterismo Periférico , Doença Arterial Periférica , Humanos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Estudos Retrospectivos , Resultado do Tratamento , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Doença Arterial Periférica/etiologia , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/cirurgia , Artéria Femoral
8.
Clin Physiol Funct Imaging ; 44(3): 228-239, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38014525

RESUMO

INTRODUCTION: Brachial cuff-based methods are increasingly used to estimate aortic systolic blood pressure (aoSBP). However, there are several unresolved issues. AIMS: to determine to what extent the scheme used to calibrate brachial records (1) can affect noninvasive obtained aoSBP levels, and consequently, the level of agreement with the aoSBP recorded invasively, and (2) how different ways of calibrating ultimately impact the relationship between aoSBP and cardiac properties. METHODS: brachial and aortic blood pressure (BP) was simultaneously obtained by invasive (catheterisation) and noninvasive (brachial oscillometric-device) methods (89 subjects). aoSBP was noninvasive obtained using three calibration schemes: 'SD': diastolic and systolic brachial BP, 'C': diastolic and calculated brachial mean BP (bMBP), 'Osc': diastolic and oscillometry-derived bMBP. Agreement between invasive and noninvasive aoSBP, and associations between BP and echocardiographic-derived parameters were analysed. CONCLUSIONS: 'C' and 'SD' schemes generated aoSBP levels lower than those recorded invasively (mean errors: 6.9 and 10.1 mmHg); the opposite was found when considering 'Osc'(mean error: -11.4 mmHg). As individuals had higher invasive aoSBP, the three calibration schemes increasingly underestimated aoSBP levels; and viceversa. The 'range' of invasive aoSBP in which the calibration schemes reach the lowest error level (-5-5 mmHg) is different: 'C': 103-131 mmHg; 'Osc': 159-201 mmHg; 'SD':101-124 mmHg. The calibration methods allowed reaching levels of association between aoSBP and cardiac characteristics, somewhat lower, but very similar to those obtained when considering invasive aoSBP. There is no evidence of a clear superiority of one calibration method over another when considering the association between aoSBP and cardiac characteristics.


Assuntos
Pressão Arterial , Determinação da Pressão Arterial , Humanos , Calibragem , Pressão Sanguínea/fisiologia , Pressão Arterial/fisiologia , Aorta , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/fisiologia
9.
Eur J Clin Invest ; 54(2): e14109, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37859571

RESUMO

INTRODUCTION: N-3 polyunsaturated fatty acids (PUFAs) supplementation has been reported to have an impact on flow-mediated dilatation (FMD), a conventionally used clinical technique for estimating endothelial dysfunction. However, its proven effects on endothelial function are unclear. This systematic review and meta-analysis were conducted to evaluate the effects of n-3 PUFAs supplementation on FMD of the brachial artery. METHOD: This study was performed following the PRISMA guidelines. To identify eligible RCTs, a systematic search was completed in PubMed/Medline, Scopus and Web of Science using relevant keywords. A fixed- or random-effects model was utilized to estimate the weighted mean difference (WMD) and 95% confidence interval (95% CI). RESULTS: Thirty-two studies (with 35 arms) were included in this meta-analysis, involving 2385 subjects with intervention duration ranging from 4 to 48 weeks. The pooled meta-analysis demonstrated a significant effect of omega-3 on FMD (WMD = 0.8%, 95% CI = 0.3-1.3, p = .001) and heterogeneity was significant (I2 = 82.5%, p < .001). CONCLUSION: We found that n-3 PUFA supplementation improves endothelial function as estimated by flow-mediated dilatation of the brachial artery.


Assuntos
Ácidos Graxos Ômega-3 , Humanos , Ácidos Graxos Ômega-3/farmacologia , Ácidos Graxos Ômega-3/uso terapêutico , Endotélio Vascular , Artéria Braquial/diagnóstico por imagem , Suplementos Nutricionais
11.
Artigo em Inglês | MEDLINE | ID: mdl-38082945

RESUMO

Flow-mediated dilation (FMD) evaluates the relative change in arterial diameter during hyperemia to assess the endothelial response due to a shear stimulus. However, conventional FMD measures diameter response alone and the alterations in the arterial wall's material properties during reactive hyperemia, which also influence dilation, go unaddressed. In this work, we examine the material response (MR) of the artery during reactive hyperemia using clinically relevant stiffness markers for the assessment of endothelial reactivity (ER). For this, we have developed an in-house brachial cuff control (BCC) system to continuously acquire brachial pressure which can be integrated with simultaneous measurement of brachial diameter and used to quantify the relative changes in wall property during hyperemia non-invasively. The assessment of endothelial reactivity using material response (ERAMR) was conducted on 20 healthy participants (12M/8F) and the results were compared with conventional FMD (FMD%). The mean pressure response gave an inverse trend to that of diameter response with varying magnitudes during reactive hyperemia (18.71% from baseline for diameter and 2.45% for pressure), there was a significant difference in the measurement of FMD and ERAMR (P < 0.05). The larger distribution of ERAMR compared to FMD% in box-plots further implies the inclusion of within-subject variations. Hence, ERAMR can be a potential estimate of ER, given the need for intensive validations in this line on larger cohorts.Clinical Relevance- This study demonstrates the independent role of arterial wall material properties to quantify endothelial reactivity in response to a shear stimulus.


Assuntos
Hiperemia , Humanos , Vasodilatação/fisiologia , Estudos de Viabilidade , Endotélio Vascular , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/fisiologia
12.
Artigo em Inglês | MEDLINE | ID: mdl-38083395

RESUMO

Endothelial reactivity (ER) is widely measured using flow-mediated dilation (FMD) of brachial artery. Conventional measurement of FMD is influenced by factors such as input shear stress, arterial transmural pressure, diameter and thereby arterial material properties (ε). Thus, for a reliable interpretation of FMD, it has to be normalized with respect to the above confounding factors. Normalization of FMD with shear stress at the time of measurement has been reported to reduce measurement variability. However, its widespread usage among the research community is limited. In this work, we examine the feasibility of normalizing the brachial FMD index (FMD%) to ε : extrema (εp), baseline (εb) and extrema change (∆ε) post-ischemia using its inter-day variability against FMD. In-vivo measurements were performed on 10 participants for 2 consecutive days and simultaneous pressure-diameter cycles were collected to estimate the material properties during reactive hyperemia (RH). The box-whisker plot reveals differences in the mean and deviation of FMD to FMD|εb. A significant value for repeatability (ICC ≥ 0.6) was obtained for normalized FMD (FMD|εb) for specific stiffness index (ß), pressure-strain elastic modulus (Ep), and local pulse wave velocity (PWV) as compared to FMD. Hence, normalization of FMD% to arterial ε can potentially improve the measurement reliability of ER assessment.Clinical Relevance- This pilot study demonstrates the feasibility of brachial artery stiffness assessment during FMD and its potential use for normalizing the standard FMD measurement.


Assuntos
Artéria Braquial , Vasodilatação , Humanos , Artéria Braquial/diagnóstico por imagem , Estudos de Viabilidade , Dilatação , Reprodutibilidade dos Testes , Projetos Piloto , Análise de Onda de Pulso , Velocidade do Fluxo Sanguíneo
13.
BMJ Case Rep ; 16(11)2023 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-37963668

RESUMO

Although tuberous sclerosis (TS) may affect many organs, vascular manifestations involving medium- and large-size vessels are rare. We present a young child with known TS who presented with bilateral posterior circulation infarcts and subsequently was found to have right-hand ischaemia secondary to a thrombosed brachial artery aneurysm. A wound on his right middle finger failed to heal with conservative management, and digital subtraction angiography and MR angiogram demonstrated a lack of bypass target with microcollateral supply of the forearm only. The right middle digit ischaemia was initially managed with right middle finger disarticulation at the metacarpophalangeal joint, but the wound failed to heal and the patient proceeded to a thumb-sparing carpo-metacarpal amputation. Aneurysms, stenotic-occlusive disease and embolic stroke are rare but important complications of TS.


Assuntos
Aneurisma , Aneurisma Intracraniano , Acidente Vascular Cerebral , Esclerose Tuberosa , Humanos , Aneurisma/diagnóstico por imagem , Aneurisma/etiologia , Aneurisma/cirurgia , Artéria Braquial/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Isquemia/complicações , Acidente Vascular Cerebral/complicações , Esclerose Tuberosa/complicações , Pré-Escolar
15.
J Clin Hypertens (Greenwich) ; 25(7): 610-617, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37378546

RESUMO

The clinical significance of central beyond brachial blood pressure (BP) remains unclear. In patients who underwent coronary angiography, the authors explored whether elevated central BP would be associated with coronary arterial disease (CAD) irrespective of the status of brachial hypertension. From March 2021 to April 2022, 335 patients (mean age 64.9 years, 69.9% men) hospitalized for suspected CAD or unstable angina were screened in an ongoing trial. CAD was defined if a coronary stenosis of ≥50%. According to the presence of brachial (non-invasive cuff systolic BP ≥140 mmHg or diastolic BP ≥90 mmHg) and central (invasive systolic BP ≥130 mmHg) hypertension, patients were cross-classified as isolated brachial hypertension (n = 23), isolated central hypertension (n = 93), and concordant normotension (n = 100) or hypertension (n = 119). In continuous analyses, both brachial and central systolic BPs were significantly related to CAD with similar standardized odds ratios (OR, 1.47 and 1.45, p < .05). While categorical analyses showed that patients with isolated central hypertension or concordant hypertension had a significantly higher prevalence of CAD and the Gensini score than those with concordant normotension. Multivariate-adjusted OR (95% confidence interval [CI]) for CAD was 2.24 (1.16 to 4.33, p = .009) for isolated central hypertension and 3.02 (1.58 to 5.78, p < .001) for concordant hypertension relative to concordant normotension. The corresponding OR (95% CI) of a high Gensini score was 2.40 (1.26-4.58) and 2.17 (1.19-3.96), respectively. In conclusion, regardless of the presence of brachial hypertension, elevated central BP was associated with the presence and severity of CAD, indicating that central hypertension is an important risk factor for coronary atherosclerosis.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Hipertensão , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Hipertensão/complicações , Hipertensão/epidemiologia , Angiografia Coronária , Artéria Braquial/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/epidemiologia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/diagnóstico por imagem , Pressão Sanguínea/fisiologia , Fatores de Risco
16.
BMC Nephrol ; 24(1): 186, 2023 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-37355570

RESUMO

BACKGROUND: Pulse wave analysis may be useful to assess fistula function. We aimed to prospectively evaluate if convenient oscillometric devices are applicable to detect flow below 500 ml/min in a real life clinical setting. METHODS: Pulse waves were recorded ambilaterally with the vicorder® device at the brachial artery in 53 patients on haemodialysis with native fistula. Primary variables consisted of the mean slope between the systolic maximum and the diacrotic notch (Slope2), the sum of the mean slopes in the four characteristic sections of pulse waves (Slope∑) and the amplitude of relative volumetric change in the measuring cuff at the upper arm (AMP). Fistula flow was measured with the use of duplex sonography using a standardized approach. RESULTS: Parameter values above or below the median indicated measurement at the non-fistula side, with sensitivities/specificities of 0.79/0.79 (p < 0.001) for Slope 2, 0.64/0.64 (p = 0.003) for Slope∑ and 0.81/0.81 (p < 0.001) for AMP if measurements at the fistula and non-fistula arm were considered. ROC-analyses of parameter values measured at the fistula to detect low flow demonstrated AUCs (with CI) of 0.652 (0.437-0.866, p = 0.167) for Slope2, 0.732 (0.566-0.899, p = 0.006) for Slope∑ and 0.775 (0.56-0.991, p = 0.012) for AMP. The point with maximal youden's index was regarded as optimal cut-off, which corresponded to sensitivities and specificities of 0.8/0.56 for slope2, 0.86/ 0.56 for Slope∑ and 0.93/0.78 for AMP. CONCLUSION: Functional surveillance with oscillometry is a promising clinical application to detect a low fistula flow. Among all investigated pulse wave parameters AMP revealed the highest diagnostic accuracy.


Assuntos
Fístula Arteriovenosa , Artéria Braquial , Humanos , Oscilometria , Artéria Braquial/diagnóstico por imagem , Sensibilidade e Especificidade , Análise de Onda de Pulso
17.
Braz J Med Biol Res ; 56: e12576, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37377306

RESUMO

Type 2 diabetes mellitus (T2DM) is characterized by endothelial dysfunction that causes micro- and macrovascular complications. Low intensity therapeutic ultrasound (LITUS) may improve endothelial function, but its effects have not been investigated in these patients. The aim of our study was to compare the effects of pulsed (PUT) and continuous (CUT) waveforms of LITUS on the endothelium-dependent vasodilation of T2DM patients. The present randomized crossover trial had a sample of twenty-three patients (7 men) diagnosed with T2DM, 55.6 (±9.1) years old, with a body mass index of 28.6 (±3.3) kg/m2. All patients were randomized and submitted to different waveforms (Placebo, CUT, and PUT) of LITUS and the arterial endothelial function was evaluated. The LITUS of 1 MHz was applied in pulsed (PUT: 20% duty cycle, 0.08 W/cm2 SATA), continuous (CUT: 0.4 W/cm2 SPTA), and Placebo (equipment off) types of waves during 5 min on the brachial artery. Endothelial function was evaluated using the flow-mediated dilation (FMD) technique. PUT (mean difference 2.08%, 95% confidence interval 0.65 to 3.51) and CUT (mean difference 2.32%, 95% confidence interval 0.89 to 3.74) increased the %FMD compared to Placebo. In the effect size analysis, PUT (d=0.65) and CUT (d=0.65) waveforms presented moderate effects in the %FMD compared to Placebo. The vasodilator effect was similar in the different types of waves. Pulsed and continuous waveforms of LITUS of 1 MHz improved the arterial endothelial function in T2DM patients.


Assuntos
Diabetes Mellitus Tipo 2 , Terapia por Ultrassom , Masculino , Humanos , Vasodilatação , Terapia por Ultrassom/métodos , Endotélio Vascular , Vasodilatadores/farmacologia , Vasodilatadores/uso terapêutico , Artéria Braquial/diagnóstico por imagem
18.
J Clin Lab Anal ; 37(9-10): e24935, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37352165

RESUMO

BACKGROUND: To investigate the correlation between brachial artery flow-mediated endothelium-dependent dilation (FMD) and platelet-lymphocyte ratio (PLR) in peripheral blood and coronary atherosclerosis in diabetic patients. METHODS: Seventy-five diabetic patients aged 62 ± 9 years, 68% male and 32% female, who underwent brachial artery endothelial function test and coronary CT scan were collected. Coronary artery calcification (CAC) was observed to assess the presence of coronary atherosclerosis, and high-resolution extravascular ultrasound was used to detect FMD. Platelet count and lymphocyte count were recorded by routine blood tests, and PLR was calculated for each study subject. Statistical methods were used to verify the association of FMD and PLR with CAC assessed by CT, respectively. RESULTS: Patients with coronary atherosclerosis had decreased FMD and increased PLR compared with patients with normal coronary arteries. Univariate logistic regression analysis showed that CAC score was significantly associated with both FMD (odds ratio: 0.167; 95% confidence interval: 0.049-0.565; p = 0.002) and PLR (odds ratio: 0.127; 95% confidence interval: 0.033-0.484; p = 0.001) at FMD < 5.1% or PLR > 130. The area under the ROC curve of FMD and PLR alone was 0.760 and 0.763, respectively. In addition, combined diagnosis of FMD and PLR showed the highest area under the ROC curve (0.830). CONCLUSION: FMD combined with PLR is expected to be a precise diagnostic modality for coronary artery calcification in diabetic patients.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Feminino , Humanos , Masculino , Artéria Braquial/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico , Linfócitos , Vasodilatação , Pessoa de Meia-Idade , Idoso
19.
Ren Fail ; 45(1): 2222853, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37340954

RESUMO

OBJECTIVE: High-flow vascular access is one of the serious complications in the maturation and subsequent use of arteriovenous fistula (AVF). We adopted a novel surgical approach named no incision limited ligation indwelling needle assisted- revision (NILLINR) to treat high-flow of the hemodialysis vascular access and ascertained the outcomes by regular follow-up visits. METHODS: This is a retrospective study. 26 hemodialysis patients with symptomatic high-flow access (access flow > 1500 mL/min) were treated with the novel banding method without incision between June 2018 and October 2020. The flow of the brachial artery before and after the restriction was measured by experienced clinicians by using the duplex Doppler ultrasound (DUS). All 26 patients were followed up for up to 1 year. Meanwhile, the brachial artery flow was recorded at 6 months and 1 year after restriction. RESULTS: Of all 26 patients included in this study, the mean access flow volume decreased from 2196.2 ± 416.9 mL/min (mean ± SD) to 679.2 ± 67.1 mL/min immediately after the operation. During the follow-up, the volume flow of the brachial artery was still within the restricted range at 6 months (mean ± SD, 720.2 ± 164.7 mL/min) and 1 year (mean ± SD, 713.9 ± 173.8 mL/min) after the operation. Meanwhile, the mean duration of the operation is 8.5 ± 3.3 min, and there is no bleeding or rupture. CONCLUSION: This novel no-incision limited ligation indwelling needle-assisted revision is a safe, effective, and time-saving option to treat high-flow access.


Assuntos
Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Humanos , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Derivação Arteriovenosa Cirúrgica/métodos , Estudos Retrospectivos , Resultado do Tratamento , Velocidade do Fluxo Sanguíneo , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/cirurgia , Ultrassonografia de Intervenção , Diálise Renal , Grau de Desobstrução Vascular , Fluxo Sanguíneo Regional
20.
Heart Vessels ; 38(10): 1228-1234, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37349561

RESUMO

Spontaneous coronary artery dissection (SCAD) is diagnosed in a very small percentage of patients with suspected acute coronary syndromes who undergo emergency coronary angiography. Although fibromuscular dysplasia (FMD) is known to coexist in patients with SCAD, the vascular sites of FMD and their frequency have not yet been clarified. We retrospectively reviewed the medical records of 16 patients who were diagnosed with and treated for SCAD at our hospital between 1 January 2011 and 31 January 2023. We have summarized their baseline and clinical characteristics and medical variables, including coronary and upper extremity angiography and in-hospital outcomes. One of our patients had concurrent cardiac tamponade requiring pericardial drainage, and another went into hemorrhage shock the following day from dissection of the gastric retroperitoneal artery. Characteristic angiographic features of partial or diffuse nonatherosclerotic stenosis were observed mainly in the distal parts of the coronary arteries or their branches. Notably, in six patients with SCAD who underwent upper extremity angiography, FMD of the brachial artery was revealed. For the first time, to our knowledge, we found a high prevalence of multifocal FMD of the brachial artery in patients with SCAD.


Assuntos
Anomalias dos Vasos Coronários , Displasia Fibromuscular , Doenças Vasculares , Humanos , Estudos Retrospectivos , Vasos Coronários/diagnóstico por imagem , Artéria Braquial/diagnóstico por imagem , Displasia Fibromuscular/diagnóstico , Displasia Fibromuscular/diagnóstico por imagem , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/etiologia , Angiografia Coronária , Extremidade Superior , Anomalias dos Vasos Coronários/diagnóstico , Anomalias dos Vasos Coronários/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA