Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.459
Filtrar
1.
Anat Histol Embryol ; 53(4): e13079, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38967773

RESUMO

This study aimed to delineate the detailed anatomy of the metacarpophalangeal (MCP) and metatarsophalangeal (MTP) joints in healthy horses using cone beam computed tomography (CBCT). The fetlock region of 15 cadaveric forelimbs and 14 cadaveric hindlimbs from nine adult horses without orthopaedic disease underwent CBCT scanning. Additionally, arthrography CBCT scans were conducted following intra-articular injection of a radiopaque contrast medium containing blue epoxy resin dye. Subsequently, limbs were frozen and sectioned to visualize anatomical structures in sectional planes corresponding to selected CBCT images. CBCT proved suitable for detailed visualization of the bony components of the fetlock region. Furthermore, the common digital extensor tendon, superficial and deep digital flexor tendons, suspensory ligament, and straight and oblique sesamoidean ligaments were identifiable on CBCT images. However, certain ligaments, such as the collateral sesamoidean ligaments and intersesamoidean ligaments, were not clearly identified. The hyaline cartilage of the MCP and MTP joint facets was assessable on the post-contrast sequence. In cases where a radiographic or ultrasound examination cannot provide a definitive diagnosis and determine the extent of disease, CBCT can provide additional valuable data on the equine MCP and MTP joint. The images obtained in this study can serve as a reference for CBCT examination of the equine MCP and MTP joint.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Membro Anterior , Membro Posterior , Animais , Cavalos/anatomia & histologia , Tomografia Computadorizada de Feixe Cônico/veterinária , Membro Anterior/anatomia & histologia , Membro Anterior/diagnóstico por imagem , Membro Posterior/anatomia & histologia , Membro Posterior/diagnóstico por imagem , Articulação Metacarpofalângica/anatomia & histologia , Articulação Metacarpofalângica/diagnóstico por imagem , Articulação Metatarsofalângica/anatomia & histologia , Articulação Metatarsofalângica/diagnóstico por imagem , Tendões/anatomia & histologia , Tendões/diagnóstico por imagem , Cadáver , Anatomia Transversal , Ligamentos/anatomia & histologia , Ligamentos/diagnóstico por imagem , Ligamentos Articulares/anatomia & histologia , Ligamentos Articulares/diagnóstico por imagem , Artrografia/veterinária , Artrografia/métodos
2.
J Biomech ; 171: 112196, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38924964

RESUMO

Lumbrical muscles originate on the flexor digitorum profundus (FDP) tendons and, during fist making, they move in the same direction when FDP muscle produces maximal proximal tendon gliding. Injuries of the bipennate lumbricals have been described when a shear force acts between the origins on adjacent tendons of the FDP, as they glide in opposite directions in asymmetric hand postures. Other structures of the deep flexors complex can be affected during this injury mechanism, due to the so-called quadriga effect, which can commonly occur during sport climbing practise. Biomechanical studies are needed to better understand the pathomechanism. A cadaveric study was designed to analyse the effects of load during the fourth lumbrical muscle injury mechanism. The amount of FDP tendon gliding and metacarpophalangeal (MCP) joint flexion of the 5th finger were calculated. Ten fresh-frozen cadaveric specimens (ten non-paired forearms and hands) were used. The specimens were placed on a custom-made loading apparatus. The FDP of the 5th finger was loaded, inducing isolated flexion of the 5th finger, until rupture. The rupture occurred in all specimens, under a load of 11 kg (SD 4.94), at 9.23 mm of proximal tendon gliding (SD 3.55) and at 21.4° (SD 28.91) of MCP joint flexion. Lumbrical muscle detachment from the 4th FDP was observed, from distal to proximal, and changes in FDP tendons at the distal forearm level too. The quadriga effect can lead to injury of the bipennate lumbrical muscles and the deep flexors complex in the hand and forearm.


Assuntos
Cadáver , Músculo Esquelético , Tendões , Humanos , Músculo Esquelético/fisiopatologia , Músculo Esquelético/fisiologia , Tendões/fisiopatologia , Tendões/fisiologia , Fenômenos Biomecânicos , Masculino , Montanhismo/fisiologia , Pessoa de Meia-Idade , Idoso , Traumatismos dos Tendões/fisiopatologia , Feminino , Antebraço/fisiopatologia , Antebraço/fisiologia , Ruptura/fisiopatologia , Articulação Metacarpofalângica/fisiopatologia , Articulação Metacarpofalângica/lesões , Modelos Biológicos
3.
Adv Rheumatol ; 64(1): 36, 2024 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702760

RESUMO

BACKGROUND: While ultrasound and MRI are both superior to clinical examination in the detection of joint inflammation, there is presently a lack of data whether thermography may be similarly useful in the assessment of joint inflammation in patients with RA. Our study aims to evaluate the use of thermography in detecting subclinical joint inflammation at clinically quiescent (non-tender and non-swollen) metacarpophalangeal joints (MCPJs) in patients with rheumatoid arthritis (RA). The outcomes from thermography in our study will be compared with ultrasonography (which is a more established imaging tool used for joint inflammation assessment in RA). METHODS: The minimum (Tmin), average (Tavg) and maximum (Tmax) temperatures at the 10 MCPJs of each patient were summed to obtain the Total Tmin, Total Tavg and Total Tmax, respectively. Ultrasound grey-scale (GS) and power Doppler (PD) joint inflammation (scored semi-quantitatively, 0-3) at the 10 MCPJs were summed up to derive the respective TGS and TPD scores per patient. Pearson's correlation and simple linear regression were respectively used to assess correlation and characterize relationships between thermographic parameters (Total Tmin, Total Tavg and Total Tmax) and ultrasound imaging parameters (TGS, TPD and the number of joint(s) with PD ≥ 1 or GS ≥ 2). RESULTS: In this cross-sectional study, 420 clinically non-swollen and non-tender MCPJs from 42 RA patients were examined. All thermographic parameters (Total Tmin, Total Tavg and Total Tmax) correlated significantly (P-values ranging from 0.001 to 0.0012) with TGS score (correlation coefficient ranging from 0.421 to 0.430), TPD score (correlation coefficient ranging from 0.383 to 0.424), and the number of joint(s) with PD ≥ 1 or GS ≥ 2 (correlation coefficient ranging from 0.447 to 0.465). Similarly, simple linear regression demonstrated a statistically significant relationship (P-values ranging from 0.001 to 0.005) between all thermographic parameters (Total Tmin, Total Tavg and Total Tmax) and ultrasound imaging parameters (TPD and TGS). CONCLUSION: For the first time, thermographic temperatures were shown to correlate with ultrasound-detected joint inflammation at clinically quiescent MCPJs. The use of thermography in the detection of subclinical joint inflammation in RA appears promising and warrants further investigation.


Assuntos
Artrite Reumatoide , Articulação Metacarpofalângica , Termografia , Humanos , Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/complicações , Termografia/métodos , Articulação Metacarpofalângica/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Ultrassonografia Doppler/métodos , Ultrassonografia , Inflamação/diagnóstico por imagem , Adulto , Idoso
4.
J Med Case Rep ; 18(1): 251, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38741133

RESUMO

INTRODUCTION: Evaluating isolated extremity discomfort can be challenging when initial imaging and exams provide limited information. Though subtle patient history hints often underlie occult pathologies, benign symptoms are frequently miscategorized as idiopathic. CASE PRESENTATION: We present a case of retained glass obscuring as acute calcific periarthritis on imaging. A 48-year-old White male with vague fifth metacarpophalangeal joint pain had unrevealing exams, but radiographs showed periarticular calcification concerning inflammation. Surgical exploration unexpectedly revealed an encapsulated glass fragment eroding bone. Further history uncovered a forgotten glass laceration decade prior. The foreign body was removed, resolving symptoms. DISCUSSION: This case reveals two imperative diagnostic principles for nonspecific extremity pain: (1) advanced imaging lacks specificity to differentiate inflammatory arthropathies from alternate intra-articular processes such as foreign bodies, and (2) obscure patient history questions unearth causal subtleties that direct accurate diagnosis. Though initial scans suggested acute calcific periarthritis, exhaustive revisiting of the patient's subtle decade-old glass cut proved pivotal in illuminating the underlying driver of symptoms. CONCLUSION: Our findings underscore the critical limitations of imaging and the vital role that meticulous history-taking plays in clarifying ambiguous chronic limb presentations. They spotlight the imperative of probing even distant trauma when symptoms seem disconnected from causative events. This case reinforces the comprehensive evaluation of all subtle patient clues as key in illuminating elusive extremity pain etiologies.


Assuntos
Calcinose , Corpos Estranhos , Vidro , Humanos , Masculino , Pessoa de Meia-Idade , Artralgia/etiologia , Calcinose/diagnóstico por imagem , Calcinose/diagnóstico , Diagnóstico Diferencial , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/complicações , Articulação Metacarpofalângica/diagnóstico por imagem , Articulação Metacarpofalângica/lesões , Periartrite/diagnóstico por imagem , Periartrite/diagnóstico , Radiografia
5.
Acta Ortop Mex ; 38(2): 119-122, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38782479

RESUMO

INTRODUCTION: metacarpophalangeal dislocations of the thumb are not very frequent injuries, it is necessary to know the anatomy of the region to know possible causes of interposition that prevent a closed reduction of this pathology. CASE PRESENTATION: we present the case of a 75-year-old woman with a post-traumatic metacarpophalangeal dislocation of the thumb that required open reduction and surgical repair. In this procedure, we performed reduction of the dislocation, mobilization of the interposed structures, repair of the capsule and reinsertion of the ulnar collateral ligament. The early mobilization protocol helped to obtain very good results. CONCLUSION: it is imperative to consider possible associated injuries during the acute phase to achieve optimal short, medium, and long-term outcomes for our patients. A comprehensive and proactive approach to diagnosis and treatment is vital in effectively addressing this pathology and minimizing its potential sequelae.


INTRODUCCIÓN: las luxaciones metacarpofalángicas del pulgar no son lesiones muy frecuentes, es necesario conocer la anatomía de la región para conocer posibles causas de interposición que impidan una reducción cerrada de esta patología. PRESENTACIÓN DEL CASO: presentamos el caso de una mujer de 75 años con luxación metacarpofalángica postraumática del pulgar que requirió reducción abierta y reparación quirúrgica. En este procedimiento realizamos reducción de la luxación, movilización de las estructuras interpuestas, reparación de la cápsula y reinserción del ligamento colateral cubital. El protocolo de movilización temprana ayudó a obtener muy buenos resultados. CONCLUSIÓN: es imperativo considerar posibles lesiones asociadas durante la fase aguda para lograr resultados óptimos a corto, mediano y largo plazo para nuestros pacientes. Un enfoque integral y proactivo del diagnóstico y tratamiento es vital para abordar eficazmente esta patología y minimizar sus posibles secuelas.


Assuntos
Ligamento Colateral Ulnar , Luxações Articulares , Articulação Metacarpofalângica , Polegar , Humanos , Articulação Metacarpofalângica/lesões , Articulação Metacarpofalângica/cirurgia , Feminino , Luxações Articulares/cirurgia , Idoso , Polegar/lesões , Polegar/cirurgia , Ligamento Colateral Ulnar/lesões , Ligamento Colateral Ulnar/cirurgia
6.
J Hand Surg Asian Pac Vol ; 29(3): 184-190, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38726488

RESUMO

Background: Untreated or insufficiently treated collateral ligament injuries of the thumb metacarpophalangeal (MP) joint can lead to instability or even osteoarthritis. Arthrodesis is one of the treatment options available for the treatment of the sequelae of collateral ligament injuries. The objective of our study was to evaluate the radiological, clinical and functional outcomes of MP joint arthrodesis performed for sequelae of collateral ligament injuries. Methods: We conducted a retrospective, single-centre study and reviewed the files of patients who had a thumb MP joint arthrodesis following a collateral ligament injury between 2011 and 2019. We collected patient's demographic data and the results of the radiological and clinical examinations. Results: Eighteen patients were included in the study. The average age was of 53.6 years and the time between injury to arthrodesis averaged 7 years. Four patients (22%) had nonunion. In the remaining 14 patients with solid union at an average of 72 months follow-up, the visual analogue pain score at rest was 0.14, the thumb opposition was 82%, grip strength 85%, tip pinch 92% and key pinch 79% of the contralateral side. Conclusions: The clinical and functional results of patients with a successful arthrodesis are satisfactory with restoration of good grip and pinch strength. Despite a lack of thumb MP joint flexion, stability allowed force transmission and may be preferred for manual workers. Level of Evidence: Level IV (Therapeutic).


Assuntos
Artrodese , Ligamentos Colaterais , Articulação Metacarpofalângica , Polegar , Humanos , Articulação Metacarpofalângica/cirurgia , Articulação Metacarpofalângica/lesões , Artrodese/métodos , Masculino , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Polegar/cirurgia , Polegar/lesões , Ligamentos Colaterais/cirurgia , Ligamentos Colaterais/lesões , Adulto , Seguimentos , Idoso , Força da Mão/fisiologia , Resultado do Tratamento
7.
Medicine (Baltimore) ; 103(16): e37868, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38640291

RESUMO

RATIONALE: The conventional treatment of giant cell tumors is intralesional curettage with local adjuvant therapy. Because hand tumors have a high local recurrence, the primary goal for treating tumors of the hand is to eradicate the lesion. PATIENT CONCERNS: To preserve the metacarpophalangeal (MCP) joint function as well as avoid further recurrence after surgery. DIAGNOSES: The giant cell tumor invades the patient's MCP joint in an index proximal phalanx. INTERVENTIONS: Using computer-aided design and three-dimensional printing techniques, we reformed the original shapes of the MCP joint and its peripheral bone to replica models. The surgeon then performed an en bloc resection and proximal phalanx with MCP joint reconstruction by fabricating the patient's costal osteochondral graft during the operation. OUTCOMES: After 6 months of rehabilitation, the patient's finger functions could pinch and grasp objects naturally. At the 1-year follow-up, the range of motion of the MCP, proximal interphalangeal, and distal interphalangeal joints improved from flexion of 35° to 60°, 75° to 85°, and 60° to 80°, respectively. The hand function achieved the mean performance of non-preferred hands for young females at the postoperative 3-year follow-up. LESSONS: The customized prototyping technique has the potential to replica the original patient's bony graft to reach the goal of minimizing the defects at the donor site and maximizing the function of the reconstructed MCP joint.


Assuntos
Prótese Articular , Neoplasias , Feminino , Humanos , Dedos , Costelas/transplante , Articulação Metacarpofalângica/cirurgia , Amplitude de Movimento Articular , Articulações dos Dedos/cirurgia
8.
Hand Surg Rehabil ; 43(3): 101696, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38657737

RESUMO

OBJECTIVES: This study aimed to report surgical technique and clinical outcomes for a novel figure-of-eight collateral ligament reconstruction technique using palmaris longus autograft for chronic irreparable collateral ligament injury of the thumb metacarpophalangeal joint. MATERIAL AND METHODS: The Jobe elbow collateral ligament reconstruction method was adapted for thumb metacarpophalangeal joint collateral ligament reconstruction. Sixteen reconstructions (7 ulnar collateral ligament, 9 radial collateral ligament) using palmaris longus autograft were reviewed retrospectively. Surgery was performed at a mean 12 months post-injury. All 16 patients were followed up for more than 1 year. Metacarpophalangeal joint radial and ulnar deviation, metacarpophalangeal and interphalangeal joint range of motion, key pinch and grip strength, Glickel functional grade and QuickDASH score were evaluated. RESULTS: Preoperative radial or ulnar deviation improved from 19.3° to 5.3° postoperatively. Metacarpophalangeal range of motion improved from 31.5° to 46.6°, and interphalangeal range of motion from 48.4° to 65.6°. Preoperative key pinch and grip strength were respectively 49% and 81% of contralateral values and improved to 82% and 87%. On Glickel grade, 9 cases were excellent and 7 good. CONCLUSION: The novel Jobe-like figure-of-eight reconstruction technique using palmaris longus graft was useful for reconstructing irreparable thumb metacarpophalangeal joint instability without an incision on the opposite side or an additional implant. LEVEL OF EVIDENCE: Therapeutic study, level IV.


Assuntos
Ligamentos Colaterais , Força da Mão , Articulação Metacarpofalângica , Amplitude de Movimento Articular , Tendões , Polegar , Humanos , Articulação Metacarpofalângica/cirurgia , Masculino , Polegar/cirurgia , Polegar/lesões , Adulto , Estudos Retrospectivos , Ligamentos Colaterais/cirurgia , Feminino , Pessoa de Meia-Idade , Tendões/transplante , Procedimentos de Cirurgia Plástica/métodos , Adulto Jovem
9.
Hand Surg Rehabil ; 43(3): 101689, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38583709

RESUMO

CASE: A 54-year-old male with osteoarthritis of the right long finger metacarpophalangeal joint underwent PyroCarbon joint arthroplasty. Seven years later the patient presented for metacarpophalangeal joint swelling and pain. The workup was benign, without signs of implant complication or osseous abnormality. He underwent washout and two-stage revision, where gross implant wear and debris not demonstrated by radiograph were found. He then returned to the operating room for reimplantation of a PyroCarbon implant. CONCLUSION: This case demonstrates a novel presentation of aseptic PyroCarbon implant failure in the hand without radiographic abnormality that can alter operative management by reducing operating room returns.


Assuntos
Prótese Articular , Articulação Metacarpofalângica , Osteoartrite , Falha de Prótese , Humanos , Masculino , Pessoa de Meia-Idade , Articulação Metacarpofalângica/cirurgia , Articulação Metacarpofalângica/diagnóstico por imagem , Osteoartrite/cirurgia , Osteoartrite/diagnóstico por imagem , Reoperação , Artroplastia de Substituição de Dedo , Carbono , Radiografia
10.
J Ultrasound Med ; 43(7): 1313-1318, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38558471

RESUMO

OBJECTIVE: This study aimed to assess the effectiveness of the Global OMERACT-EULAR Synovitis Score (GLOESS) of bilateral second to fifth metacarpophalangeal joints (MCP 2-5) in evaluating rheumatoid arthritis (RA) activity in a real-life setting. METHODS: This cross-sectional study included consecutive RA patients without hyperalgesia. Clinical data were extracted from electronic medical records. Evaluations were conducted on bilateral MCP 2-5 by two independent experts in musculoskeletal ultrasound (MSUS). Correlation between clinical and ultrasonographic parameters was analyzed, aiming to define a cutoff value for detecting disease activity. RESULTS: Sixty-nine patients were included. The mean DAS28-ESR was 4.3 (±1.4), and the median GLOESS was 7 (13). The correlation between GLOESS and DAS28 was moderate (r = .62; P < .05). A total GLOESS score of ≤3 and all joints with both GS and PD ≤1 showed good sensitivity and specificity for detecting disease activity (remission/low vs moderate/high, P = 0). CONCLUSION: In a real-life scenario, GLOESS for MCP 2-5 emerges as a valuable measure of RA activity. The optimal cutoff distinguishing remission/low from moderate/high disease activity was determined to be GLOESS ≤3, with all MCP joints exhibiting both GS and PD scores of ≤1.


Assuntos
Artrite Reumatoide , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Sinovite , Ultrassonografia , Humanos , Artrite Reumatoide/diagnóstico por imagem , Feminino , Masculino , Estudos Transversais , Pessoa de Meia-Idade , Sinovite/diagnóstico por imagem , Ultrassonografia/métodos , Reprodutibilidade dos Testes , Articulação Metacarpofalângica/diagnóstico por imagem , Idoso , Adulto
11.
J Strength Cond Res ; 38(5): 948-950, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38662886

RESUMO

ABSTRACT: Peveler, WW, Schoffstall, J, Coots, J, Kilian, J, and Glauser, J. The effects of boxing glove design on thumb position when making a fist for striking. J Strength Cond Res 38(5): 948-950, 2024-It has been suggested that boxing glove design alters thumb position increasing the risk of injury. The purpose of this study was to determine the effects of boxing glove design on thumb joint angles when making a fist. Ten experienced fighters participated in this study. A DEXA scan was used to produce an x-ray image of thumb position for all conditions (no gloves and 10-oz boxing gloves). Mean values for dependent measures were compared using a paired-sample T test and an alpha of 0.05. The carpometacarpal (CMC) joint angle was significantly different between no glove (14.1 ± 6.54°) and boxing glove (34.2 ± 7.60°) at p ≤ 0.001. The metacarpophalangeal (MP) joint angle was significantly different between no glove (132.6 ± 12.74°) and boxing glove (149.40 ± 8.15°) at p ≤ 0.001. The IP joint angle was not significantly different between no glove (135.50 ± 19.12°) and boxing glove (144.40 ± 17.39°) at p = 0.269. The perpendicular distance from the second metacarpal of the hand to the center of the MP joint was significantly different between no glove (0.48 ± 0.54 cm) and boxing glove (1.84 ± 0.29 cm) at p ≤ 0.001. Use of a boxing glove resulted in abduction of the thumb away from the hand and increased CMC and MP joint angles that were significantly different in relation to making a fist without a glove. Information from this study may provide insight into the high rate of thumb injury and provide insight for future boxing glove design.


Assuntos
Desenho de Equipamento , Polegar , Humanos , Polegar/fisiologia , Adulto , Masculino , Boxe/fisiologia , Articulação Metacarpofalângica/fisiologia , Articulações Carpometacarpais , Adulto Jovem , Luvas Protetoras
12.
Morphologie ; 108(361): 100770, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38428155

RESUMO

BACKGROUND: The metacarpophalangeal (MCP) joint's collateral ligaments have been extensively debated, with no clear consensus on their mechanics. Understanding their function is crucial for comprehending joint movement and stability. METHODS: A thorough search was conducted across databases, including PubMed, Scopus, Cochrane library and grey literature. A total of 59 articles were identified, and after rigorous evaluation, six articles were included in the review. RESULTS: The analysis underscores two principal findings. Firstly, the principal and accessory collateral ligaments exhibit consistent tension influenced by the MCP joint's position. This tension varies across different sections of the ligaments. Secondly, the ligaments' interaction with the joint structure plays a pivotal role in defining the range of motion of the joint. CONCLUSION: Preliminary findings from this review indicate that MCP joint collateral ligament tension varies with joint position. Increased tension in the principal collateral ligament during flexion and isometric behavior of its volar portion in extension are observed. The accessory ligament may tighten during extension. The shape of the metacarpal head appears to influence this tension. These insights, while informative, call for further detailed research to deepen our understanding of MCP joint mechanics.


Assuntos
Ligamentos Colaterais , Articulação Metacarpofalângica , Amplitude de Movimento Articular , Articulação Metacarpofalângica/fisiologia , Articulação Metacarpofalângica/anatomia & histologia , Humanos , Ligamentos Colaterais/anatomia & histologia , Ligamentos Colaterais/fisiologia , Amplitude de Movimento Articular/fisiologia , Fenômenos Biomecânicos
13.
J Biomech Eng ; 146(7)2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38456821

RESUMO

The thumb carpometacarpal (CMC) joint is one of the most likely joints to develop osteoarthritis (OA). If conservative treatments fail to alleviate symptoms, surgery may be pursued. Kinematic outcomes of CMC surgery techniques have been described, but current tools have limitations in capturing motion abilities. The goals of this study were (1) develop a new and robust set of kinematic outcome measures, and apply them to (2) a cohort of younger and older control individuals without CMC OA to determine age and sex-related changes, and (3) a cohort of participants with CMC OA before, 3 months, and 6 months after undergoing thumb ligament reconstruction with tendon interposition surgery to detect the impacts of surgery. 52 (26 males, 26 females) control and 18 (3 males, 15 females) surgical participants were tested. Kinematics were investigated using motion capture by mapping the three-dimensional motion space of the whole thumb, and two-dimensional motion boundaries of the metacarpal (MC) and proximal phalange (PP). Visual analog pain score was recorded. Older control participants had shifted regions of motion compared to younger participants (p ≤ 0.027), suggesting asymptomatic CMC wear. Control females had 31% more metacarpophalangeal (MCP) motion than control males (p = 0.013), which could alter loading paths through the CMC joint and increase OA risk. Pain at 6 months postsurgery was 72% less than presurgery (p < 0.001), but motion abilities were 20-28% less than presurgery (p ≤ 0.074) and 24-40% less than control participants (p ≤ 0.066). These techniques have the possibility of identifying presymptomatic motion changes, including those at the metacarpophalangeal joint in CMC OA progression.


Assuntos
Articulações Carpometacarpais , Osteoartrite , Masculino , Feminino , Humanos , Polegar/cirurgia , Fenômenos Biomecânicos , Osteoartrite/cirurgia , Articulação Metacarpofalângica/cirurgia , Articulações Carpometacarpais/cirurgia , Ligamentos Articulares , Dor
14.
J Hand Surg Am ; 49(5): 432-442, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38506782

RESUMO

PURPOSE: The purpose of this study was to compare clinical and radiologic outcomes of biological ligament reconstruction (BLR) versus nonbiological ligament reconstruction (NBLR) for chronic injuries involving the ulnar collateral ligament of the thumb's metacarpophalangeal joint. METHODS: Forty-two patients who underwent static BLR (n = 24) or NBLR (n = 18) were included in this retrospective analysis. Preoperative, postoperative, and contralateral thumb measurements (clinical evaluation, radiographs, and subjective outcome questionnaires) were compared over a mean of 38 months of follow-up. RESULTS: Average postoperative thumb metacarpophalangeal and interphalangeal joint ranges of motion were 2° to 54° and 0 to 71°, respectively, for BLR and 0° to 58° and 0° to 71°, respectively, for NBLR. Average grip and pinch strengths, relative to the unaffected hand, were 102% and 84% versus 103% and 89%, respectively. All patients demonstrated stability with a firm end point, compared with the unaffected thumb. The average Quick Disabilities of the Arm, Shoulder, and Hand score among all patients was 12 for the disability/symptom module, 0 for the sports module, and 17 for the work module. Stiffness was reported among four patients, and no patient sustained wound-related issues or other complications. CONCLUSIONS: Nonbiological ligament reconstruction of the thumb ulnar collateral ligament generates short-term outcomes comparable with those of BLR, potentially allowing for expedited recovery and rehabilitation. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.


Assuntos
Ligamento Colateral Ulnar , Articulação Metacarpofalângica , Amplitude de Movimento Articular , Polegar , Humanos , Polegar/cirurgia , Polegar/lesões , Articulação Metacarpofalângica/cirurgia , Estudos Retrospectivos , Masculino , Feminino , Adulto , Amplitude de Movimento Articular/fisiologia , Ligamento Colateral Ulnar/cirurgia , Ligamento Colateral Ulnar/lesões , Pessoa de Meia-Idade , Reconstrução do Ligamento Colateral Ulnar , Força da Mão , Resultado do Tratamento , Avaliação da Deficiência , Adulto Jovem , Procedimentos de Cirurgia Plástica/métodos , Ligamentos Colaterais/cirurgia , Ligamentos Colaterais/lesões
15.
Acta Med Okayama ; 78(1): 71-78, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38419317

RESUMO

We retrospectively investigated the mid-term outcomes of arthroplasty using the AVANTA silicone implant for thumb metacarpophalangeal (MCP) joints with boutonniere deformity in patients with rheumatoid arthritis (RA). This study involved 36 thumbs of 33 RA patients with a mean follow-up period of 5.1 years (range, 2.0-13.3). Postoperatively, the mean extension was significantly increased and the mean flexion was significantly decreased (p<0.001, p<0.001, respectively), resulting in the mean arc of range of motion (ROM) shifting in the direction of extension after surgery. Implant fracture was observed in 10 thumbs (28%), and 4 of these (11%) underwent revision surgery. The survivorship with implant fracture and revision surgery as endpoints were 73.4% and 91.8% at 5 years, respectively. The preoperative arc of ROM and the postoperative flexion range of the implant-fracture group were significantly greater than those in the no-implant-fracture group (p=0.039, 0.034, respectively). These results suggest the importance of patient education and careful rehabilitation to prevent excessive flexion. Overall, the AVANTA silicone implant showed a relatively high rate of implant fracture at our institute.


Assuntos
Artrite Reumatoide , Deformidades Adquiridas da Mão , Prótese Articular , Humanos , Polegar/cirurgia , Prótese Articular/efeitos adversos , Estudos Retrospectivos , Articulação Metacarpofalângica/cirurgia , Artrite Reumatoide/complicações , Artrite Reumatoide/cirurgia , Artroplastia , Deformidades Adquiridas da Mão/cirurgia , Amplitude de Movimento Articular , Silicones
16.
Orthop Surg ; 16(4): 984-988, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38311800

RESUMO

OBJECTIVES: The position of sesamoid of thumb metacarpophalangeal (MCP) joint changed clearly when the joint was dislocated dorsally. However, the significance of sesamoid location in diagnosing joint dislocation was unclear. The present study aimed to explore the positional relationship between sesamoid bone and thumb metacarpophalangeal joint in normal and dorsal dislocation joints. METHODS: Between January 2018 and August 2023, we collected 60 isometric plain films from sixty outpatients and reviewed 56 anisometric plain films from twenty-eight emergency patients with dorsal dislocation of thumb MCP joint at Tianjin Hospital, then took measurements on the hand X-ray images. The sesamoid length on its longitudinal axis was defined as DP, the distance between the distal edge of sesamoid and thumb MCP joint was defined as DJ, and the ratio of DJ and DP was R. An independent-samples t-test and paired-samples t-test was utilized to analyze difference among data groups. RESULTS: The 60 isometric images were from 30 male and 30 female outpatients with normal bone structure in their hands, and the 56 anisometric images of the 28 emergency patients included both preoperative and postoperative materials. Among the outpatients, the actual distance between the distal edge of sesamoid and thumb MCP joint space (DJ) was 2.09 mm and 1.40 mm in males and females, respectively. The authentic average length of sesamoid (DP) was 4.46 mm in males and 4.22 mm in females. The average value of R (the ratio of DJ and DP) in males and females was 0.49 and 0.34, respectively. There were gender-related statistical differences in DJ (p < 0.01) and R (p=0.01), but no statistical difference in DP (p > 0.05). For the 28 emergency patients, the mean value of R was -0.47 before joint reduction and 0.58 after joint reduction, with statistical difference between them (p < 0.01). CONCLUSIONS: There was significant difference in the relative position between sesamoid and thumb MCP joint when joint dislocation and joint reduction. The distal edge of sesamoid beyond thumb MCP joint could be an evidence in diagnosing joint dorsal dislocation. The distal edge of sesamoid below thumb MCP joint could be an evidence of joint reduction.


Assuntos
Luxações Articulares , Polegar , Humanos , Masculino , Feminino , Polegar/diagnóstico por imagem , Estudos Retrospectivos , Luxações Articulares/diagnóstico por imagem , Radiografia , Articulação Metacarpofalângica/diagnóstico por imagem , Articulação Metacarpofalângica/cirurgia
17.
J Hand Surg Am ; 49(5): 443-449, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38402479

RESUMO

PURPOSE: The primary objective of this study was to compare the long-term survival rates of silicone metacarpophalangeal (MCP) arthroplasties between two major implants in patients with rheumatoid arthritis, using implant fracture as an end point. We also evaluated the difference in postoperative function between patients with fractured and intact implants as a secondary objective. METHODS: A retrospective cohort study was conducted on 372 fingers of 133 hands that underwent silicone MCP arthroplasty between January 2000 and June 2019 (mean follow-up, 7.6 years). The survival rates of Swanson-type and Sutter-type implants were compared, using implant fracture as the end point after a radiographic evaluation. Clinical measures and upper limb functional assessments using the Disabilities of the Arm, Shoulder, and Hand (DASH) score were performed in the nested cohort. RESULTS: The 10.6-year survival rates for implant fracture of Swanson- and Sutter-type implants were 86.2% and 9.4%, respectively, with significantly higher survival noted for Swanson-type implants. The Sutter-type implant showed increased susceptibility to fracture in all four fingers compared to the Swanson-type implant. Implant fractures were primarily observed at the stem-hinge junction. There were no significant differences in upper limb function between the fractured and intact implant groups. CONCLUSIONS: Sutter-type implants were found to be more prone to fracture compared with Swanson-type implants. However, implant fractures did not significantly affect upper limb function. TYPE OF STUDY/LEVEL OF EVIDENCE: Prognosis IV.


Assuntos
Artrite Reumatoide , Artroplastia de Substituição de Dedo , Prótese Articular , Articulação Metacarpofalângica , Falha de Prótese , Silicones , Humanos , Artrite Reumatoide/cirurgia , Artrite Reumatoide/complicações , Articulação Metacarpofalângica/cirurgia , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Prótese Articular/efeitos adversos , Idoso , Avaliação da Deficiência , Adulto , Desenho de Prótese
20.
Mod Rheumatol Case Rep ; 8(2): 391-393, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38217486

RESUMO

Snapping of fingers can be caused by pathologies such as stenosing flexor tenosynovitis. However, snapping symptoms in the metacarpophalangeal (MP) joint caused by hypertension and hyperplasia of the lateral band are rare. We present a 26-year-old female with symptoms of painful snapping of the middle finger. When the finger was actively flexed from the hyperextension of the MP joint, the ulnar lateral band was prominent, and a snapping phenomenon occurred. The cause of the snapping finger was considered to be tightness of the ulnar lateral band, and surgery was planned. Intraoperatively, the ulnar lateral band was tense and hyperplastic. The snapping phenomenon disappeared immediately after the resection of the lateral band. It is important to consider this condition as one of the differential diagnoses of snapping finger when the patient complains of an atypical snapping phenomenon.


Assuntos
Hiperplasia , Humanos , Feminino , Adulto , Hiperplasia/diagnóstico , Dedos , Articulação Metacarpofalângica/cirurgia , Diagnóstico Diferencial , Dor/etiologia , Dor/diagnóstico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA