RESUMO
BACKGROUND: Thoracic computed tomography scans (CT) are used by several study groups to investigate the circulatory structures (heart and vessels) located behind the pressure point for chest compressions. Yet, it remains unclear how the positioning of these structures is influenced by factors such as intubation, the respiratory cycle and arm positioning. METHODS: We retrospectively analyzed data of adult patients with in- or out-of-hospital cardiac arrest who underwent thoracic CT imaging within one year before or up to six months after arrest. A region of interest (ROI) behind the pressure point was defined. The largest structure within this region was defined as "leading circulatory structure", which was the primary outcome. Airway status (intubated versus spontaneous breathing), respiratory cycle (inspiration, expiration, resting expiratory position), and arm position (up over the head versus down beside the trunk) served as covariates in an ordinal regression model. RESULTS: Among 500 initially screened patients, 411 (82.2 %) were included in the analysis. There was a significant association between the arm position and the leading circulatory structure behind the pressure point. However, no association was found with airway status or respiratory cycle. The most frequently identified leading circulatory structure was the left atrium (arms up: 41.8 %, down: 50.7 %), followed by the ascending aorta (up: 23.8 % vs. down: 16.7 %). The left ventricle was the leading structure in only one case (0.2 %, arms down). CONCLUSION: This study shows that arm position is significantly associated with the leading circulatory structure behind the pressure point for chest compressions in cardiac arrest.
Assuntos
Reanimação Cardiopulmonar , Posicionamento do Paciente , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Reanimação Cardiopulmonar/métodos , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Posicionamento do Paciente/métodos , Tomografia Computadorizada por Raios X/métodos , Parada Cardíaca/terapia , Parada Cardíaca/diagnóstico por imagem , Parada Cardíaca/fisiopatologia , Braço/diagnóstico por imagem , Braço/irrigação sanguínea , Pressão , Adulto , Radiografia Torácica/métodosRESUMO
BACKGROUND: When applied to thermoacoustic imaging (TAI), the delay-and-sum (DAS) algorithm produces strong sidelobes due to its disadvantages of uniform aperture weighting. As a result, the quality of TAI images recovered by DAS is often severely degraded by strong non-coherent clutter, which restricts the development and application of TAI. PURPOSE: To address this issue, we propose an adaptive complementary neighboring sub-aperture (NSA) beamforming algorithm for TAI. METHODS: In NSA, we introduce a coordinate system transformation when calculating the normalized cross-correlation (NCC) matrix. This approach enables the computation of the NCC coefficient within the specified kernel without complex coordinate calculations. We first conducted the numerical simulation experiment to validate NSA using a tree branch phantom. In addition, we also conducted phantom (five sauce tubes), ex vivo (ablation needle in ex vivo porcine liver), and in vivo (human arm) TAI experiments using our TAI system with a center frequency of 3 GHz. RESULTS: In the numerical simulation experiment, the structural similarity index (SSIM) value for NSA is increased from 0.37828 for DAS to 0.75492. In the point target phantom TAI experiment, the generalized contrast-to-noise ratio (gCNR) value for NSA is increased from 0.936 for DAS to 0.962. The experimental results show that NSA can recover clearer thermoacoustic images compared to DAS. In the ex vivo TAI experiment, the full width at half maxima (FWHM) of an ablation needle (diameter = 1.5 mm) for coherence factor (CF) weighted DAS and NSA are 0.9 and 1.3 mm, respectively. Furthermore, in the in vivo TAI experiment, CF reduces the signals within the arm compared to NSA. Therefore, compared with CF, NSA can maintain the integrity of target information in TAI while effectively suppressing non-coherent background clutter. CONCLUSIONS: NSA can effectively reduce non-coherent background noise while ensuring the completeness of the target information. So, NSA offers the potential to provide high-quality thermoacoustic images and further advance their clinical application.
Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Animais , Suínos , Processamento de Imagem Assistida por Computador/métodos , Humanos , Acústica , Razão Sinal-Ruído , Fígado/diagnóstico por imagem , Braço/diagnóstico por imagem , TemperaturaRESUMO
INTRODUCTION/AIMS: Myotonia is a key symptom of myotonic dystrophies (DM), and its quantification is challenging. This exploratory study evaluated the utility of tissue Doppler ultrasound (TDU) to assess myotonia in DM. METHODS: Twelve DM patients (seven type-1 DM [DM1] and five type-2 DM [DM2]) and 20 age-matched healthy subjects were included in this cross-sectional study. After measuring cross-sectional areas of the flexor digitorum superficialis (FDS) and extensor digitorum communis (EDC) muscles in a resting state, muscle contraction/relaxation time, time to peak tissue velocity, peak tissue velocity and velocity gradients of these muscles were measured via TDU while performing forced fist unclenching after fist closure. Additionally, grip strength, Medical Research Council Sum score and patient-reported myotonia severity scores were assessed. RESULTS: DM1 and DM2 patients had a lower grip strength than healthy subjects (p = .0001/p = .002). Patient-reported myotonia did not differ between DM1 and DM2 patients. DM1 patients revealed FDS and EDC atrophy compared to DM2 patients and healthy subjects (p = .003/p = .004). TDU revealed prolonged muscle contraction and relaxation times in both DM subtypes, with prolonged time to reach FDS peak relaxation velocity and altered peak FDS relaxation velocity only in DM1 patients (p = .03/p = .003). Peak FDS relaxation velocity correlated inversely with C(C)TG repeat numbers in DM patients. Sensitivity of TDU parameters to detect myotonic dystrophy varied between 50% and 75%, with a specificity of 95%. DISCUSSION: Our exploratory study suggests that TDU could serve as a novel tool to quantify myotonia in DM patients, but larger follow-up studies are warranted to validate its diagnostic accuracy.
Assuntos
Braço , Força da Mão , Músculo Esquelético , Miotonia , Distrofia Miotônica , Ultrassonografia Doppler , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Miotonia/fisiopatologia , Miotonia/diagnóstico por imagem , Distrofia Miotônica/diagnóstico por imagem , Distrofia Miotônica/fisiopatologia , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiopatologia , Estudos Transversais , Força da Mão/fisiologia , Ultrassonografia Doppler/métodos , Braço/fisiopatologia , Braço/diagnóstico por imagem , Contração Muscular/fisiologia , IdosoRESUMO
Background: Lymphedema is a common complication after mastectomy in women with breast cancer. Several methods have been described to assess and diagnose lymphedema, one of the most studied being the perimeter and ultrasonography. However, the reliability of these methods and the correlation between them are still controversial. The aim of this study was to analyze the reliability of cytometry and ultrasound imaging in the assessment of lymphedema after mastectomy in women with breast cancer and to study the correlation between them. Methods and Results: A cross-sectional study was conducted in 29 women with mastectomy after breast cancer. Lymphedema in the arm was measured both with cytometry and ultrasonography. Reliability was calculated with intraclass correlation coefficient. The correlation between the two methods was carried out with the Pearson correlation coefficient. Both cytometry (M1: α = 0.999, ICC = 0.996; M2: = α = 0.998, ICC = 0.994) and ultrasonography (M1: α = 0.992, ICC = 0.976; M2: = α = 0.991, ICC = 0.973) are reliable methods to assess lymphedema in the arm. No significant correlation was found between them (p > 0.05). Conclusions: Cytometry and ultrasonography appear to be adequate for the measurement of edema in women with breast cancer after mastectomy. However, for an accurate measurement of lymphedema, these measurements should not be used interchangeably.
Assuntos
Neoplasias da Mama , Linfedema , Mastectomia , Ultrassonografia , Humanos , Feminino , Mastectomia/efeitos adversos , Neoplasias da Mama/cirurgia , Neoplasias da Mama/complicações , Neoplasias da Mama/patologia , Pessoa de Meia-Idade , Estudos Transversais , Linfedema/etiologia , Linfedema/diagnóstico , Linfedema/diagnóstico por imagem , Linfedema/patologia , Adulto , Idoso , Reprodutibilidade dos Testes , Braço/patologia , Braço/diagnóstico por imagem , Linfedema Relacionado a Câncer de Mama/etiologia , Linfedema Relacionado a Câncer de Mama/diagnósticoRESUMO
ABSTRACT: A 51-year-old woman with a 2-mm-Breslow-thickness melanoma on her arm had 99mTc-nanocolloid lymphoscintigraphy to localize the associated sentinel lymph node. A single axillary node was identified, and histology confirmed a micrometastasis of breast tissue origin. Imaging of the patient's breasts and subsequent biopsy confirmed ipsilateral stage III breast cancer, which was treated with lumpectomy and axillary node clearance. This is the first reported case of an incidental solid cancer diagnosis from a sentinel lymph node biopsy undertaken for a different tumor origin. This illustrates the importance of recognizing overlapping lymphatic distribution of sentinel lymph nodes, which can drain multiple organs.
Assuntos
Braço , Neoplasias da Mama , Achados Incidentais , Linfocintigrafia , Melanoma , Neoplasias Cutâneas , Agregado de Albumina Marcado com Tecnécio Tc 99m , Humanos , Feminino , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Melanoma/diagnóstico por imagem , Melanoma/patologia , Neoplasias Cutâneas/diagnóstico por imagem , Neoplasias Cutâneas/patologia , Braço/diagnóstico por imagem , Melanoma Maligno Cutâneo , Biópsia de Linfonodo SentinelaRESUMO
BACKGROUND: Streak artifacts induced by irregular arm positioning have been an issue in diagnosing the abdomen. PURPOSE: To illustrate the risk of misdiagnosis in abdominal computed tomography (CT) of patients with irregular arm positioning through a case-by-case evaluation and to test if it can be solved by the artificial intelligence iterative reconstruction (AIIR) algorithm. MATERIAL AND METHODS: By reviewing 5220 cases of chest and thoracoabdominal CT, 64 patients with irregular arm positioning were enrolled, whose image data were reconstructed using AIIR in addition to routine hybrid iterative reconstruction (HIR). Lesion detection for livers, spleens, kidneys, gallbladders, and pancreas on AIIR images, performed by two radiologists, was compared with those on HIR images. Discrepancies arising from AIIR images included both cases with additional abnormalities and those with corrections made on previous detections. For cases with discrepancies, artifact scores for organs where discrepancies were found, and contrast-to-noise ratios (CNRs) of cysts with discrepancies were compared between two image sets. RESULTS: Additional abnormalities were detected for 15 cases: additional liver cirrhosis (n=2); additional gallbladder stone (n=1); additional cholecystitis (n=1), additional spleen nodule (n=1); additional kidney cysts (n=8); additional liver cysts (3); and additional spleen cyst (n=1). A spleen contusion was corrected for one case. All involved artifact scores were improved on AIIR images. CNRs of involved liver, kidney, and spleen cysts were improved by up to 539.7%, 538.5%, and 245.5%, respectively. CONCLUSION: Irregular arm positioning may induce a variety of misdiagnoses in abdominal CT, which is almost totally avoidable by the AIIR algorithm.
Assuntos
Artefatos , Inteligência Artificial , Posicionamento do Paciente , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Abdominal , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Radiografia Abdominal/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Posicionamento do Paciente/métodos , Adulto , Idoso de 80 Anos ou mais , Algoritmos , Braço/diagnóstico por imagem , Estudos Retrospectivos , Erros de DiagnósticoRESUMO
Spectral imaging has the potential to become a key technique in interventional medicine as it unveils much richer optical information compared to conventional RBG (red, green, and blue)-based imaging. Thus allowing for high-resolution functional tissue analysis in real time. Its higher information density particularly shows promise for the development of powerful perfusion monitoring methods for clinical use. However, even though in vivo validation of such methods is crucial for their clinical translation, the biomedical field suffers from a lack of publicly available datasets for this purpose. Closing this gap, we generated the SPECTRAL Perfusion Arm Clamping dAtaset (SPECTRALPACA). It comprises ten spectral videos (â¼20 Hz, approx. 20,000 frames each) systematically recorded of the hands of ten healthy human participants in different functional states. We paired each spectral video with concisely tracked regions of interest, and corresponding diffuse reflectance measurements recorded with a spectrometer. Providing the first openly accessible in human spectral video dataset for perfusion monitoring, our work facilitates the development and validation of new functional imaging methods.
Assuntos
Pele , Humanos , Pele/irrigação sanguínea , Pele/diagnóstico por imagem , Gravação em Vídeo , Mãos/irrigação sanguínea , Braço/irrigação sanguínea , Braço/diagnóstico por imagemRESUMO
INTRODUCTION: During Computed Tomography (CT) scans of the Thorax-Abdomen-Pelvis (TAP) the patient's arms should be positioned above the head to obtain optimal image quality and expose the patient to the lowest possible radiation dose. This may be impossible with patients with shoulder problems leading to arms being positioned in other ways. This study aimed to investigate differences in objective image quality and estimated effective dose (E), when positioning the arms below shoulder level in CT-TAP. METHODS: An anthropomorphic phantom with cadaver arms was used. Four arm positions were tested: Along the torso (A), on the pelvis (B), on a pillow on the pelvis (C), and one arm on pillow on the pelvis and the other arm on the pelvis (D). A Siemens SOMATOM Definition Flash CT-scanner with CareDose 4D was used. The dose length product was read to estimate E. Image quality was assessed objectively by measuring noise within the region of interest in the liver and urinary bladder. RESULTS: Significant differences in E between all arm positions were seen (p = 0.005). The lowest E was obtained in position C, reducing E by 8.42%. Position A provided the best image quality but the highest E. CONCLUSION: This study showed no unequivocal optimal positioning of arms in CT-TAP. Position A provided the best object image quality, while position C yielded the lowest E. These results may impact the planning of diagnostic CT where positioning of arms may influence optimal image quality and radiation dose. IMPLICATION FOR PRACTICE: This study illustrates tendencies for objective image quality and E when arms are positioned below shoulder level. Further research is needed to assess the clinical relevance with the diagnostic potential.
Assuntos
Braço , Posicionamento do Paciente , Imagens de Fantasmas , Doses de Radiação , Radiografia Abdominal , Radiografia Torácica , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Braço/diagnóstico por imagem , Radiografia Torácica/métodos , Radiografia Abdominal/métodos , CadáverRESUMO
Selective fascicular involvement of the median nerve trunk above the elbow leading to anterior interosseous nerve (AIN) syndrome is a rare form of peripheral neuropathy. This condition has recently garnered increased attention within the medical community owing to advancements in imaging techniques and a growing number of reported cases. In this article, we explore the topographical anatomy of the median nerve trunk and the clinical features associated with AIN palsy. Our focus extends to unique manifestations captured through MRI and ultrasonography (US) studies, highlighting noteworthy findings, such as nerve fascicle swelling, incomplete constrictions, hourglass-like constrictions, and torsions, particularly in the posterior/posteromedial region of the median nerve. Surgical observations have further enhanced the understanding of this complex neuropathic condition. High-resolution MRI not only reveals denervation changes in the AIN and median nerve territories but also illuminates these alterations without the presence of compressing structures. The pivotal roles of high-resolution MRI and US in diagnosing this condition and guiding the formulation of an optimal treatment strategy are emphasized.
Assuntos
Imageamento por Ressonância Magnética , Nervo Mediano , Ultrassonografia , Humanos , Imageamento por Ressonância Magnética/métodos , Nervo Mediano/diagnóstico por imagem , Ultrassonografia/métodos , Braço/inervação , Braço/diagnóstico por imagem , Neuropatia Mediana/diagnóstico por imagem , SíndromeRESUMO
BACKGROUND: The importance of several scapulothoracic muscles, including trapezius and serratus anterior, in maintaining physiological scapula kinematics has been highlighted in the past. However, the relationship between the scapula and the latissimus dorsi muscle remains unclear. Our clinical surgical observation is that the latissimus dorsi does not directly attach but rather runs superficial to the inferior angle of the scapula. Based on this observation, we hypothesise that the latissimus dorsi creates a dynamic track on which the scapula glides under the muscle belly during elevation of the arm, creating the latissimus-scapula overlap (LSO). METHODS: All consecutive patients who had a whole-body computed tomography scan (CT) in case of polytrauma evaluation between 2018 and 2021, with complete depiction of the scapula and latissimus dorsi muscle, were analysed. 150 shoulders in 90 patients with arms up were matched according to their age (within five years), gender, and affected side with 150 shoulders in 88 patients with arms down. Patients with pathologies of the upper extremities or thorax that potentially could alter LSO measurements were excluded. LSO was calculated as a ratio of the measured area of the latissimus dorsi projection on the scapula and the total scapula area. RESULTS: The mean age of the 178 patients (48 females; 13 males) was 60 years. The arms-up group showed a significantly higher LSO than the arms-down group (19.9 ± 6.3% vs. 2.7 ± 2.2%; p < 0.0001). In the arms-up group, approximately one fifth of the scapula was overlapped inferiorly by the muscle belly of the latissimus dorsi, contrary to the almost non-existing LSO in the arms-down group. CONCLUSION: With arms up, humans show a significantly higher LSO in comparison to arms down indicating that the latissimus dorsi indeed creates a dynamic track on which the scapula is forced to travel during abduction of the arm. This finding of increased LSO during the elevation of the arm warrants further consideration of the role of the latissimus dorsi in scapula kinematics and potentially scapular dyskinesis. LEVEL OF EVIDENCE: Level two diagnostic study.
Assuntos
Anormalidades Congênitas , Escápula/anormalidades , Articulação do Ombro/anormalidades , Músculos Superficiais do Dorso , Masculino , Feminino , Humanos , Pré-Escolar , Músculos Superficiais do Dorso/diagnóstico por imagem , Braço/diagnóstico por imagem , Escápula/cirurgia , OmbroRESUMO
INTRODUCTION: This retrospective cohort study examined the effects of the crossed raised arm (CRA) position in contrast-enhanced computed tomography (CECT) on contrast medium influx and image quality relative to the conventional position. METHODS: Contrast medium influx into the collateral veins on CECT images was evaluated in 92 participants. The CT values of the pulmonary artery, descending aorta, and spleen were obtained in both positions and compared. Anatomical changes in the diameters and area of the subclavian vein and costoclavicular distance were also analyzed. RESULTS: Contras 27 and 6 patients in the conventional and CRA positions, respectively. The influx risk ratio in the CRA position versus that in the conventional position was 0.22 (95% confidence interval, 0.10-0.51). Elevations in the median CT value of the pulmonary artery, descending aorta, and spleen in the CRA position were 7.0% (p < .001), 7.4% (p < .001), and 9.8% (p < .001), respectively. Enlargements in the major and minor diameters of the subclavian vein, subclavian vein area, and costoclavicular distance in the CRA position versus those in the conventional position were 19.3% (p < .001), 28.1% (p < .001), 53.6%, and 30.0% (p < .001), respectively. CONCLUSION: The CRA position effectively prevented contrast medium influx into the collateral veins due to SVS and increased CT values in the target organs in CECT. The diameters and area of the subclavian vein and costoclavicular distance were enlarged at the thoracic outlet, which improved the flow of the contrast medium into the targeted organs. IMPLICATIONS FOR PRACTICE: The CRA position can contribute to obtaining better CECT images during common clinical assessments at no additional cost.
Assuntos
Braço , Tomografia Computadorizada por Raios X , Humanos , Braço/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , AbdomeRESUMO
INTRODUCTION: This study aimed to investigate and compare the effective dose (ED) delivered by computed tomography (CT) in whole-body positron emission tomography/CT (WB-PET/CT) scans between patients positioned with their arms-raised and those with their arms-lowered during the scan on a large population. METHODS: The retrospective study involved 785 oncology patients who underwent WB-PET/CT scans with 18F-FDG between January and June 2019. Exclusion criteria were applied, resulting in a final analysis of data from 732 adult patients. All of the patients were measured height and weight, and the ED from CT in WB-PET/CT was estimated using the dose length product value and a conversion factor. Statistical analyses were conducted to explore relationships between factors and the ED. Linear regression analysis was performed to investigate connections between weight and ED, and height and ED. Multiple linear regression was used to predict ED based on sex, weight, and arm position. RESULTS: The arm-lowered group had a higher ED than the arm-raised group, and the median dose was 1.1 times higher in the arm-lowered group. The difference in ED between the two groups was found to be greater with higher body weight. Arm-position (ß = 0.460), sex (ß = -0.190), and weight (ß = 0.057) were significant predictors of ED. CONCLUSION: This study demonstrated that arm position, sex, and weight were significant factors influencing the ED from CT scans in WB-PET/CT. IMPLICATIONS FOR PRACTICE: The research underscores the importance of considering these factors when evaluating radiation exposure in clinical practice, particularly for patients undergoing WB-CT imaging. These findings contribute to a better understanding of the radiation dosimetry associated with different patient positions during WB-PET/CT scans.
Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Humanos , Braço/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Masculino , FemininoRESUMO
The creation of unique control methods for a hand prosthesis is still a problem that has to be addressed. The best choice of a human-machine interface (HMI) that should be used to enable natural control is still a challenge. Surface electromyography (sEMG), the most popular option, has a variety of difficult-to-fix issues (electrode displacement, sweat, fatigue). The ultrasound imaging-based methodology offers a means of recognising complex muscle activity and configuration with a greater SNR and less hardware requirements as compared to sEMG. In this study, a prototype system for high frame rate ultrasound imaging for prosthetic arm control is proposed. Using the proposed framework, a virtual robotic hand simulation is developed that can mimic a human hand as illustrated in the link: https://youtu.be/LBcwQ0xzQK0. The proposed classification model simulating four hand gestures has a classification accuracy of more than 90%.Clinical relevance-The proposed system enables an ultrasound imaging based human machine interface that can be a research and development platform for novel control strategies of a hand prosthesis.
Assuntos
Membros Artificiais , Robótica , Humanos , Braço/diagnóstico por imagem , Eletromiografia/métodos , Extremidade SuperiorRESUMO
PURPOSE: Studies examining mortality in palliative care units are limited. We aimed to investigate the mortality and associated factors including ultrasonographic muscle parameters in hospitalized palliative patients with a subgroup analysis of older patients. METHODS: A prospective-observational study. We recorded the demographics, number of diseases, diagnoses, and the Charlson comorbidity index (CCI), palliative performance scale (PPS), and nutritional risk screening-2002 (NRS-2002) scores. We noted the nutritional parameters and mortality. We measured the subcutaneous fat thickness (SFT), muscle thickness (MT), and cross-sectional area (CSA) of the rectus femoris and biceps brachii using ultrasonography. RESULTS: We enrolled 100 patients (mean age: 73.2 ± 16.4 years, 53%: female). One-month mortality was 42%. The non-survivors had significantly higher malignancy, increased CCI and NRS-2002 scores, lower required energy intake, calorie sufficiency rate, and biceps brachii SFT, MT, and CSA than the survivors. The independent mortality predictors were malignancy and biceps brachii CSA while the PPS score and malignancy were significantly associated with mortality in the older subgroup. CONCLUSION: The malignancy and biceps brachii CSA might have prognostic value in predicting mortality in palliative patients. This was the first study investigating the mortality-associated factors including ultrasonographic muscle measurements of both the lower and upper limbs in a palliative care center.
Assuntos
Músculo Esquelético , Neoplasias , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos Prospectivos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Braço/diagnóstico por imagem , Ultrassonografia , Neoplasias/diagnóstico por imagemRESUMO
Shear wave elastography is an emerging diagnostic tool used to assess for changes in the stiffness of muscle. Each region of the muscle may have a different stiffness; therefore, the anatomical region should be carefully selected. Machine vendors each have unique methods for calculating the returned stiffness values and, consequently, a high level of agreement in measurement between machines (quantified using the intraclass correlation coefficient [ICC] and Bland-Altman analysis) will allow research findings to be translated to the clinic. This study assessed three locations within the biceps muscle (50% and 75% of the distance between the acromioclavicular joint and antecubital fossa, and superior to distal myotendinous junction [MTJ]) of 32 healthy volunteers with two different machines, the Canon Aplio i600 and SuperSonic Imagine Aixplorer (SSI), to compare the reported shear wave velocities and the variability by coefficient of variation (CV) and ICC. There was no difference in the CV between machines, but a significant difference in the CV at muscle regions, with the 75% location having a 40.2% reduction in CV. The 75% location had the highest ICC values with good posterior mean ICCs of 0.84 on the Canon and 0.83 on the SSI. The 50% and MTJ locations had poor ICC values. The 75% location provided the lowest CV and highest ICC and should be used for future stiffness assessments.
Assuntos
Técnicas de Imagem por Elasticidade , Humanos , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia/métodos , Braço/diagnóstico por imagem , Músculo Esquelético/diagnóstico por imagem , Cotovelo , Reprodutibilidade dos TestesRESUMO
INTRODUCTION AND OBJECTIVES: Obtaining CCTA images with optimal injection location such as the arm or leg is important to avoid the artifacts caused by the CM. This study compares the computed tomography (CT) numbers and visualization scores of the three-dimensional (3D) images of the lumens of the blood vessels in the arm or leg during cardiac computed tomography angiography (CCTA) in neonatal and infant patients. PATIENTS OR MATERIALS AND METHODS: Between January 2017 and January 2020, 253 consecutive patients were considered for inclusion. We used the estimated propensity scores as a function of the demographic data, including age, body weight, and injection location (right or left side) in the arm (nâ¯=â¯58) and leg (nâ¯=â¯58) of neonatal and infant patients. We compared the mean CT numbers of the pulmonary artery, ascending aorta, and left superior vena cava; contrast-noise ratios (CNR); and visualization scores between the arm and leg as the injection locations. RESULTS: The mean CT numbers during CCTA for the arm and leg were 479.4 and 461.3 HU in the ascending aorta, 464.2 and 448.1 HU in the pulmonary artery, and 232.8 and 220.1 HU in the left superior vena cava, respectively. The mean image noise (SD) and CNR values, respectively, were 38.9 HU and 12.1 for the arm as the injection location and 39.1 HU and 12.3 for the leg as the injection location. The median visualization scores of volume rendering of the 3D images were 3.0 and 3.0 for the arm and leg injection sites, respectively. There were no significant differences in the mean CT numbers of the ascending aorta, pulmonary artery, and left superior vena cava; SD value; CNR; and visualization scores between the arm and leg injection locations. CONCLUSIONS: The CT numbers of the lumen of the blood vessel and visualization scores of the 3D images of the arm and leg injection locations are equal during CCTA in neonatal and infant patients with congenital heart disease.
Assuntos
Meios de Contraste , Veia Cava Superior , Humanos , Lactente , Recém-Nascido , Braço/diagnóstico por imagem , Perna (Membro) , Tomografia Computadorizada por Raios X/métodosRESUMO
This study was to explore the application value for central venous stenosis and occlusion in hemodialysis patients under the CT angiography based on intelligent segmentation algorithm, so that patients can survive better. Spiral CT was used to examine upper limb swelling in 62 uremic hemodialysis patients at a speed of 3.8 mL/s. Nonionic iodine contrast agent was injected around the contralateral limb. The total dosage of 90-102 mL, it was scanned by intelligent trigger technology. The trigger scanning threshold was set. The monitoring point was located in the superior vena cava. CT with convolutional neural network intelligent segmentation algorithm was used to process image data. Finally, the quality of life and related biochemical levels of patients before and after hemodialysis were detected. Under the CT angiography of intelligent segmentation algorithm, 77 stenoses were found in 62 uremic patients, including 48 stenoses of the brachial vein and 17 stenoses of the superior vena cava. The correlation coefficient between CT angiography and digital subtraction angiography (DSA) imaging results of intelligent segmentation algorithm was 0.411. Segmentation effect of the algorithm in this study: automatic segmentation accuracy was greater than 79%. After hemodialysis treatment, the scores of physical fitness, pain, social function, and energy status of patients were significantly increased compared with those before treatment, and the levels of albumin, serum phosphorus, and parathyroid hormone were significantly decreased (P < 0.05). In summary, CT angiography with intelligent segmentation algorithm can obtain clear, intuitive, and complete vascular walking images, and better display subclavian vein, brachiocephalic vein, and superior vena cava. It can provide more valuable support for surgical intervention and has certain application value for better survival of hemodialysis patients.
Assuntos
Algoritmos , Angiografia por Tomografia Computadorizada/métodos , Diálise Renal , Adulto , Idoso , Angiografia Digital/métodos , Angiografia Digital/estatística & dados numéricos , Braço/diagnóstico por imagem , Biologia Computacional , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Edema/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional/métodos , Imageamento Tridimensional/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Tomografia Computadorizada Multidetectores/estatística & dados numéricos , Redes Neurais de Computação , Diálise Renal/efeitos adversos , Trombose Venosa Profunda de Membros Superiores/diagnóstico por imagem , Trombose Venosa Profunda de Membros Superiores/etiologia , Uremia/diagnóstico por imagem , Uremia/terapia , Dispositivos de Acesso Vascular/efeitos adversos , Veia Cava Superior/diagnóstico por imagem , Adulto JovemRESUMO
Quantitative magnetic resonance imaging (qMRI) is frequently used to map the disease state and disease progression in the lower extremity muscles of patients with spinal muscular atrophy (SMA). This is in stark contrast to the almost complete lack of data on the upper extremity muscles, which are essential for carrying out daily activities. The aim of this study was therefore to assess the disease state in the upper arm muscles of patients with SMA in comparison with healthy controls by quantitative assessment of fat fraction, diffusion indices, and water T2 relaxation times, and to relate these measures to muscle force. We evaluated 13 patients with SMA and 15 healthy controls with a 3-T MRI protocol consisting of DIXON, diffusion tensor imaging, and T2 sequences. qMRI measures were compared between groups and related to muscle force measured with quantitative myometry. Fat fraction was significantly increased in all upper arm muscles of the patients with SMA compared with healthy controls and correlated negatively with muscle force. Additionally, fat fraction was heterogeneously distributed within the triceps brachii (TB) and brachialis muscle, but not in the biceps brachii muscle. Diffusion indices and water T2 relaxation times were similar between patients with SMA and healthy controls, but we did find a slightly reduced mean diffusivity (MD), λ1, and λ3 in the TB of patients with SMA. Furthermore, MD was positively correlated with muscle force in the TB of patients with SMA. The variation in fat fraction further substantiates the selective vulnerability of muscles. The reduced diffusion tensor imaging indices, along with the positive correlation of MD with muscle force, point to myofiber atrophy. Our results show the feasibility of qMRI to map the disease state in the upper arm muscles of patients with SMA. Longitudinal data in a larger cohort are needed to further explore qMRI to map disease progression and to capture the possible effects of therapeutic interventions.
Assuntos
Braço , Atrofia Muscular Espinal , Braço/diagnóstico por imagem , Imagem de Tensor de Difusão/métodos , Progressão da Doença , Humanos , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/patologia , Atrofia Muscular Espinal/diagnóstico por imagem , Extremidade Superior/diagnóstico por imagem , ÁguaRESUMO
BACKGROUND: Flail arm syndrome is a restricted phenotype of motor neuron disease that is characterized by progressive, predominantly proximal weakness and atrophy of the upper limbs. OBJECTIVE: The study was designed to investigate specific white matter alterations in diffusion tensor imaging (DTI) data from flail arm syndrome patients using a hypothesis-guided tract-of-interest-based approach to identify in vivo microstructural changes according to a neuropathologically defined amyotrophic lateral sclerosis (ALS)-related pathology of the cortico-efferent tracts. METHODS: DTI-based white matter mapping was performed both by an unbiased voxel-wise statistical comparison and by a hypothesis-guided tract-wise analysis of fractional anisotropy (FA) maps according to the neuropathological ALS-propagation pattern for 43 flail arm syndrome patients vs 43 'classical' ALS patients vs 40 matched controls. RESULTS: The analysis of white matter integrity demonstrated regional FA reductions for the flail arm syndrome group predominantly along the CST. In the tract-specific analysis according to the proposed sequential cerebral pathology pattern of ALS, the flail arm syndrome patients showed significant alterations of the specific tract systems that were identical to 'classical' ALS if compared to controls. CONCLUSIONS: The DTI study including the tract-of-interest-based analysis showed a microstructural involvement pattern in the brains of flail arm syndrome patients, supporting the hypothesis that flail arm syndrome is a phenotypical variant of ALS.
Assuntos
Esclerose Lateral Amiotrófica , Doenças Vasculares , Esclerose Lateral Amiotrófica/complicações , Esclerose Lateral Amiotrófica/diagnóstico por imagem , Esclerose Lateral Amiotrófica/patologia , Anisotropia , Braço/diagnóstico por imagem , Braço/patologia , Mapeamento Encefálico , Imagem de Tensor de Difusão/métodos , Progressão da Doença , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tratos PiramidaisRESUMO
OBJECTIVES: Semiautomatic fractional limb volume (FLV) models have recently produced promising results for fetal birth weight (BW) estimation. We tested those models in a more unselected population hypothesizing that the FLV models would improve accuracy and precision of fetal BW estimation compared to the Hadlock model. METHODS: We compared the performance of different BW prediction models: Hadlock (biparietal diameter [BPD], abdominal circumference (AC), femur diaphysis length) and modified Lee thigh volume (TVol) and arm volume (AVol) (BPD, AC, automated fractional TVol, and AVol). Accuracy (systematic errors, mean percent differences) and precision (random errors, ± 1 SD of percent differences) were calculated. RESULTS: A total of 75 fetuses were included for final analysis. The Hadlock model showed the most consistent results with accurate BW estimation not significantly different from zero (-0.37 ± 8.53%). The modified fractional thigh and arm volume models were less accurate but trended toward more precise results (-2.63 ± 7.69% and -3.85 ± 7.47%, respectively). In addition, the modified TVol model showed the trend to predict more BWs within ±10% of the actual BW compared to the Hadlock model (81.3 versus 74.67%, ns). CONCLUSIONS: Based on our results, fetal weight estimation using the modified semiautomatic FLV models generates less accurate results in third-trimester fetuses compared to the Hadlock model. Those models recently published might improve the results of BW prediction by showing a higher precision than conventional models, especially in small and large fetuses. Further studies are needed to investigate the clinical usefulness of the new models.