Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.020
Filtrar
1.
Med J Malaysia ; 79(4): 375-379, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39086332

RESUMO

INTRODUCTION: Vernal keratoconjunctivitis (VKC) is a chronic allergic disease characterised by intense ocular surface symptoms and corneal involvement. There is limited data about the corneal changes in children with VKC based on severity of the disease. We aimed to compare the central corneal thickness (CCT) and corneal topographic indices in Malaysian children with VKC, as well as among the varying grades of VKC severity. MATERIALS AND METHODS: This study is a comparative, crosssectional and hospital-based study. We recruited 83 children with VKC and 83 healthy children as controls. All children underwent complete ocular examinations, CCT measurement using an ultrasound pachymeter and corneal topography using a Placido disc corneal analyser. RESULTS: There was a statistically significant difference of means CCT and topographic indices in children with VKC compared to controls (p<0.05). The probability keratoconus reached 18% in children with VKC. The mean CCT was observed to be thinnest in the severe-to-very severe groups of VKC compared to the mild-to-moderate (p<0.05). The means simulated-K1 and -K2, apical keratometry, apical gradient curvature, superior-inferior index and keratoconus prediction index were significantly different in severe-tovery severe VKC compared to mild-to-moderate VKC and controls (p<0.05). However, there was no significant difference in mean cylinder value and percent probability keratoconus when comparing different groups of severity of VKC (p=0.912 and 0.070 respectively). CONCLUSION: Children with VKC have thinner CCT and topographic indices changes compared to healthy children. Similar pattern was observed between groups with VKC. Degree of astigmatism and probability of keratoconus were similar in mild-to-moderate and severe-to-very severe groups.


Assuntos
Conjuntivite Alérgica , Córnea , Topografia da Córnea , Humanos , Conjuntivite Alérgica/diagnóstico por imagem , Conjuntivite Alérgica/patologia , Criança , Masculino , Feminino , Malásia , Córnea/patologia , Córnea/diagnóstico por imagem , Estudos Transversais , Adolescente , Estudos de Casos e Controles , Índice de Gravidade de Doença , Ceratocone/diagnóstico por imagem , Ceratocone/patologia
3.
Int Ophthalmol ; 44(1): 347, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39138825

RESUMO

PURPOSE: Altered corneal biomechanics in patients with diabetes may affect intraocular pressure (IOP) measurements. Although a relationship between IOP and glucose levels has been reported in diabetic and nondiabetic patients, the mechanism by which hyperglycemia influences IOP is unclear. The aim of this study was to determine the effects of hyperglycemia on IOP, corneal biomechanics, and anterior segment parameters during the oral glucose tolerance test (OGTT) in nondiabetic patients. METHODS: Twenty-one patients without DM who underwent OGTT were included in this study. A complete ophthalmologic examination was performed before the test. Blood glucose, insulin level, IOP (iCare rebound tonometer), Ocular Response Analyzer, and corneal topography (Pentacam) measurements were obtained at 0, 1, and 2 h during the OGTT. Data from the patients' right eyes were included in the analysis. RESULTS: The mean age of the patients was 46.9 ± 11.0 years. There was a statistically significant difference in IOP between 1 and 2 h (p = 0.03) and a clinically significant difference between 0 and 1 h (p = 0.06). Corneal resistance factor was lower at 2 h than 1 h (p = 0.03), while central cornea thickness was increased at 1 h (p = 0.01) and 2 h (p = 0.05) compared to 0 h. There was positive partial correlation between hyperglycemia and IOP at 1 h (p = 0.049, r = 0.67). CONCLUSION: The positive partial correlation between IOP and glucose level suggests that acute hyperglycemia may lead to increased IOP. However, further research is needed to explain the mechanism of IOP elevation in the hyperglycemic phase during OGTT.


Assuntos
Glicemia , Córnea , Topografia da Córnea , Teste de Tolerância a Glucose , Hiperglicemia , Pressão Intraocular , Tonometria Ocular , Humanos , Pressão Intraocular/fisiologia , Feminino , Teste de Tolerância a Glucose/métodos , Masculino , Córnea/fisiopatologia , Córnea/diagnóstico por imagem , Córnea/patologia , Pessoa de Meia-Idade , Hiperglicemia/fisiopatologia , Hiperglicemia/diagnóstico , Glicemia/metabolismo , Glicemia/análise , Fenômenos Biomecânicos , Topografia da Córnea/métodos , Adulto
4.
Arq Bras Oftalmol ; 88(1): e20230160, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39109743

RESUMO

PURPOSE: To determine the clinical outcomes in patients after type 1 Boston keratoprosthesis surgery and the significance of ultrasound biomicroscopy imaging for postoperative follow-up. METHODS: This retrospective analysis included 20 eyes of 19 patients who underwent corneal transplantation with type 1 Boston keratoprosthesis between April 2014 and December 2021. Data on patient demographics, preoperative diagnosis, visual acuity, and postoperative clinical findings were analyzed. RESULTS: Type 1 Boston keratoprosthesis implantation resulted in intermediate- and long-term positive outcomes. However, blindness and other serious complications such as glaucoma, retroprosthetic membrane formation, endophthalmitis, or retinal detachment also occurred. The use of ultrasound biomicroscopy imaging allowed for better evaluation of the back of the titanium plate, anterior segment structures, and the relationship of the prosthesis with surrounding tissues, which provided valuable postoperative information. CONCLUSION: Regular lifetime monitoring and treatment are necessary in patients who undergo Boston type 1 keratoprosthesis implantation for high-risk corneal transplantation. ultrasound biomicroscopy imaging can be a valuable imaging technique for the evaluation of patients with Boston type 1 keratoprosthesis, providing important information on anterior segment anatomy and potential complications. Further studies and consensus on postoperative follow-up protocols are required to optimize the management of patients with Boston type 1 keratoprosthesis.


Assuntos
Doenças da Córnea , Microscopia Acústica , Próteses e Implantes , Acuidade Visual , Humanos , Microscopia Acústica/métodos , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Doenças da Córnea/cirurgia , Doenças da Córnea/diagnóstico por imagem , Resultado do Tratamento , Idoso , Complicações Pós-Operatórias/diagnóstico por imagem , Transplante de Córnea/métodos , Período Pós-Operatório , Implantação de Prótese/métodos , Córnea/diagnóstico por imagem , Córnea/cirurgia , Adulto Jovem , Órgãos Artificiais , Adolescente
5.
Arq Bras Oftalmol ; 88(1): e20230056, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39109737

RESUMO

PURPOSE: This study aimed to analyze variations in intraoperative corneal thickness during corneal cross-linking in patients with keratoconus and to investigate its possible correlation with presurgical maximal keratometry (Kmax) and pachymetry. METHODS: This was a prospective case series. We used a method similar to the Dresden protocol, with the application of hydroxypropyl methylcellulose 0.1% hypo-osmolar riboflavin in corneas between 330 and 400 µm after epithelium removal. Corneal thickness was measured using portable calipers before and immediately after epithelium removal, and 30 and 60 min after the procedure. RESULTS: The 30 patients in this study were followed up for one year. A statistically significant difference was observed in pachymetry values during the intraoperative period (p<0.0001) and an increase of 3.05 µm (95%C1: 0.56-5.54) for each diopter was seen after epithelium removal (p0.019). We found an average Kmax difference of -2.12 D between men and women (p0.013). One year after treatment, there was a statistically significant reduction in pachymetry (p<0.0001) and Kmax (p0.0170) values. CONCLUSIONS: A significant increase in pachymetry measurements was seen during the procedure, and most patients showed a regression in Kmax and pachymetry values one year after surgery.


Assuntos
Córnea , Paquimetria Corneana , Reagentes de Ligações Cruzadas , Derivados da Hipromelose , Ceratocone , Fármacos Fotossensibilizantes , Riboflavina , Humanos , Riboflavina/uso terapêutico , Feminino , Ceratocone/tratamento farmacológico , Masculino , Paquimetria Corneana/métodos , Estudos Prospectivos , Adulto , Reagentes de Ligações Cruzadas/uso terapêutico , Adulto Jovem , Córnea/diagnóstico por imagem , Córnea/patologia , Córnea/cirurgia , Córnea/efeitos dos fármacos , Derivados da Hipromelose/uso terapêutico , Fármacos Fotossensibilizantes/uso terapêutico , Adolescente , Resultado do Tratamento , Fatores de Tempo , Período Intraoperatório , Valores de Referência , Topografia da Córnea/métodos , Reprodutibilidade dos Testes
6.
J Refract Surg ; 40(8): e569-e578, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39120013

RESUMO

PURPOSE: To assess the corneal biomechanical properties in normal individuals and patients with keratoconus using the Brillouin optical scanning system (Intelon Optics) (BOSS) and compare them with ultra-high-speed Scheimpflug imaging (Corvis ST; Oculus Optikgeräte GmbH). METHODS: Sixty eyes from 60 patients (30 normal and 30 keratoconus) were included in this prospective, single-center, comparative, non-interventional study. Corneal biomechanics were evaluated using the Corvis ST and the BOSS. With the BOSS, each corneal image was acquired three times, measuring 10 locations within an 8-mm diameter. Parameters extracted included mean, maximum, and minimum Brillouin shift. These 10 points were also grouped into superior, central, and inferior regions. BOSS repeatability was assessed using the coefficient of repeatability and coefficient of variation. Furthermore, normal individuals and patients with keratoconus were compared using the Corvis ST and BOSS. RESULTS: The BOSS exhibited good repeatability, with coefficient of repeatability ranging from 0.098 to 0.138 GHz for single points in normal individuals and 0.096 to 0.149 GHz for patients with keratoconus. Statistical analysis revealed significant differences between normal individuals and patients with keratoconus, indicating softer corneas in keratoconus, observed with both the Corvis ST and BOSS. Specifically, the BOSS showed significant differences in mean, inferior, and superior mean, maximum, and minimum Brillouin frequency shift (all P < .05), whereas the Corvis ST displayed highly significant differences in stiffness parameter at first applanation, stress strain index, deformation amplitude ratio, and inverse integrated radius (all P < .001). CONCLUSIONS: Corneal biomechanical measurements proved highly repeatable and effectively demonstrated significant differences between normal individuals and patients with keratoconus using both the BOSS and the Corvis ST. [J Refract Surg. 2024;40(8):e569-e578.].


Assuntos
Córnea , Topografia da Córnea , Elasticidade , Ceratocone , Humanos , Estudos Prospectivos , Ceratocone/fisiopatologia , Ceratocone/diagnóstico , Córnea/fisiopatologia , Córnea/diagnóstico por imagem , Masculino , Fenômenos Biomecânicos , Adulto , Feminino , Adulto Jovem , Elasticidade/fisiologia , Reprodutibilidade dos Testes , Microscopia , Pessoa de Meia-Idade , Adolescente
8.
Sci Rep ; 14(1): 15517, 2024 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-38969757

RESUMO

CorneAI for iOS is an artificial intelligence (AI) application to classify the condition of the cornea and cataract into nine categories: normal, infectious keratitis, non-infection keratitis, scar, tumor, deposit, acute primary angle closure, lens opacity, and bullous keratopathy. We evaluated its performance to classify multiple conditions of the cornea and cataract of various races in images published in the Cornea journal. The positive predictive value (PPV) of the top classification with the highest predictive score was 0.75, and the PPV for the top three classifications exceeded 0.80. For individual diseases, the highest PPVs were 0.91, 0.73, 0.42, 0.72, 0.77, and 0.55 for infectious keratitis, normal, non-infection keratitis, scar, tumor, and deposit, respectively. CorneAI for iOS achieved an area under the receiver operating characteristic curve of 0.78 (95% confidence interval [CI] 0.5-1.0) for normal, 0.76 (95% CI 0.67-0.85) for infectious keratitis, 0.81 (95% CI 0.64-0.97) for non-infection keratitis, 0.55 (95% CI 0.41-0.69) for scar, 0.62 (95% CI 0.27-0.97) for tumor, and 0.71 (95% CI 0.53-0.89) for deposit. CorneAI performed well in classifying various conditions of the cornea and cataract when used to diagnose journal images, including those with variable imaging conditions, ethnicities, and rare cases.


Assuntos
Catarata , Doenças da Córnea , Humanos , Catarata/classificação , Catarata/diagnóstico , Doenças da Córnea/classificação , Doenças da Córnea/diagnóstico , Fotografação/métodos , Inteligência Artificial , Córnea/patologia , Córnea/diagnóstico por imagem , Curva ROC
9.
J Refract Surg ; 40(7): e445-e452, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007818

RESUMO

PURPOSE: To evaluate the repeatability of automatic measurements of a new anterior segment optical coherence tomographer (ANTERION; Heidelberg Engineering) and their agreement with an anterior segment optical coherence tomography device combined with Placido disc corneal topography (MS-39; CSO) in patients affected by keratoconus. METHODS: Fifty-four consecutive patients were included. Three measurements were performed with the ANTERION and one with the MS-39. Repeatability was assessed by means of within-subject standard deviation, coefficient of variation (CoV), and intraclass correlation coefficient (ICC). Agreement was investigated with the 95% limits of agreement. The paired t-test and Wilcoxon matched-pairs test were performed to compare the measurements of the different devices. RESULTS: Repeatability of ANTERION measurements was high, with an ICC greater than 0.98 for all parameters. Many parameters revealed a CoV of less than 1% and a CoV within 5% was obtained for astigmatism measurements. The ANTERION measured a significantly higher corneal power and the MS-39 more negative posterior keratometric values. These differences were mirrored by a moderate agreement for mean simulated keratometry and poor agreement for total corneal power and posterior keratometry. CONCLUSIONS: The ANTERION revealed high repeatability of automatic measurements and good agreement with the MS-39 for many parameters in patients affected by keratoconus, but for most parameters the two instruments cannot be considered interchangeable. [J Refract Surg. 2024;40(7):e445-e452.].


Assuntos
Segmento Anterior do Olho , Topografia da Córnea , Ceratocone , Tomografia de Coerência Óptica , Humanos , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Tomografia de Coerência Óptica/métodos , Reprodutibilidade dos Testes , Adulto , Topografia da Córnea/métodos , Masculino , Feminino , Segmento Anterior do Olho/diagnóstico por imagem , Adulto Jovem , Biometria/instrumentação , Biometria/métodos , Estudos Prospectivos , Córnea/patologia , Córnea/diagnóstico por imagem , Pessoa de Meia-Idade , Adolescente
10.
BMC Ophthalmol ; 24(1): 275, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38970043

RESUMO

BACKGROUND: To compare the repeatability and reproducibility of corneal and corneal epithelial thickness mapping using anterior segment optical coherence tomography (AS-OCT) according to tear film break-up time (TBUT). METHODS: The included eyes were divided into three subgroups according to TBUT (group 1: TBUT ≤ 5 s, group 2: 5 s < TBUT ≤ 10 s, and group 3: TBUT > 10 s). All eyes were imaged separately thrice by two operators to obtain the thickness maps (TMs) of the cornea and corneal epithelium based on spatial zones encompassing a 9-mm-diameter area. Each TM consisted of 25 areas. Intraoperator (repeatability) and interoperator (reproducibility) standard deviations (Sws), coefficients of variation (CoVs), and intraclass correlation coefficients (ICCs) among the tests were calculated and compared in all the areas. RESULTS: Altogether, 132 eyes of 67 subjects were included (50, 47, and 35 eyes in groups 1, 2, and 3; respectively). The ICCs of corneal epithelial thickness and corneal thickness were > 0.75 in most of the areas. Pairwise comparisons showed that AS-OCT exhibited lower repeatability in group 1 than in groups 2 and 3 (P < 0.05). However groups 2 and 3 showed similar results. Sws and CoVs of corneal epithelial thickness exhibited no significant interoperator differences. While no significant differences were observed in corneal thickness in most of the areas. CONCLUSIONS: TBUT significantly influences the repeatability of corneal and corneal epithelial thickness measurements. Poor tear film stability requires careful evaluation of corneal epithelial thickness.


Assuntos
Córnea , Lágrimas , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Feminino , Reprodutibilidade dos Testes , Masculino , Lágrimas/fisiologia , Córnea/diagnóstico por imagem , Adulto , Pessoa de Meia-Idade , Epitélio Corneano/diagnóstico por imagem , Adulto Jovem , Paquimetria Corneana/métodos , Idoso
11.
Sci Rep ; 14(1): 16614, 2024 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-39025900

RESUMO

Dynamic deformation events induced by osmosis or photochemical stiffening substantially influence geometrical and mechanical assessments in post-mortem corneas, therefore need to be carefully monitored in experimental settings. In this study, we employed optical coherence elastography (OCE) to quantify dynamic deformation processes at high resolution in freshly enucleated porcine corneas. Osmotic effects were studied by immerging n = 9 eyes in preservation media of three different tonicities. Dynamic processes underlying corneal cross-linking (CXL) were studied by subjecting n = 6 eyes to standard Dresden treatment, while three control groups were used. The entire procedures were performed under an OCE setup during up to 80 min, acquiring a volumetric scan every 20 s. Changes in OCE-derived axial deformations were incrementally calculated between consecutive scans. Preservation conditions had a strong influence on the observed strain patterns, which were consistent with the tonicity of the medium (swelling in hypotonic, deswelling in hypertonic environment). In the CXL group, we observed deswelling of the anterior stroma 10 min after starting the UV irradiation, which was not observed in any control group (p = 0.007). The presented results proved OCE to be a valuable technique to quantify subtle dynamic biomechanical alterations in the cornea resulting from CXL and preservation solutions.


Assuntos
Córnea , Crosslinking Corneano , Técnicas de Imagem por Elasticidade , Tomografia de Coerência Óptica , Animais , Córnea/efeitos dos fármacos , Córnea/diagnóstico por imagem , Córnea/metabolismo , Difusão , Técnicas de Imagem por Elasticidade/métodos , Osmose , Suínos , Tomografia de Coerência Óptica/métodos , Raios Ultravioleta
12.
Ophthalmic Physiol Opt ; 44(6): 1224-1236, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38980216

RESUMO

PURPOSE: To optimise the precision and efficacy of orthokeratology, this investigation evaluated a deep neural network (DNN) model for lens fitting. The objective was to refine the standardisation of fitting procedures and curtail subjective evaluations, thereby augmenting patient safety in the context of increasing global myopia. METHODS: A retrospective study of successful orthokeratology treatment was conducted on 266 patients, with 449 eyes being analysed. A DNN model with an 80%-20% training-validation split predicted lens parameters (curvature, power and diameter) using corneal topography and refractive indices. The model featured two hidden layers for precision. RESULTS: The DNN model achieved mean absolute errors of 0.21 D for alignment curvature (AC), 0.19 D for target power (TP) and 0.02 mm for lens diameter (LD), with R2 values of 0.97, 0.95 and 0.91, respectively. Accuracy decreased for myopia of less than 1.00 D, astigmatism exceeding 2.00 D and corneal curvatures >45.00 D. Approximately, 2% of cases with unique physiological characteristics showed notable prediction variances. CONCLUSION: While exhibiting high accuracy, the DNN model's limitations in specifying myopia, cylinder power and corneal curvature cases highlight the need for algorithmic refinement and clinical validation in orthokeratology practice.


Assuntos
Topografia da Córnea , Miopia , Redes Neurais de Computação , Procedimentos Ortoceratológicos , Refração Ocular , Humanos , Procedimentos Ortoceratológicos/métodos , Estudos Retrospectivos , Miopia/terapia , Miopia/fisiopatologia , Feminino , Masculino , Refração Ocular/fisiologia , Adolescente , Córnea/patologia , Córnea/diagnóstico por imagem , Lentes de Contato , Adulto Jovem , Criança , Adulto , Acuidade Visual/fisiologia
13.
BMC Ophthalmol ; 24(1): 289, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39014346

RESUMO

BACKGROUND: This study assessed the agreement of ocular parameters of patients with myopia measured using Colombo intraocular lens (IOL) 2 and IOLMaster 700. METHODS: Eighty patients (male, 22; average age, 29.14 ± 7.36 years) with myopia (159 eyes) were included in this study in May 2023. The participants' axial length (AXL), central corneal thickness (CCT), lens thickness (LT), white-to-white distance (WTW), front flat (K1), steep (K2), mean (Km) corneal keratometry, astigmatism (Astig), J0 vector, and J45 vector were measured using the IOLMaster 700 and Colombo IOL 2. The measurements from both devices were compared using the generalized estimating equation, correlation analysis, and Bland-Altman plots. RESULTS: With the Colombo IOL 2, lower values for K2 and J0 (odds ratio [OR] = 0.587, p = 0.033; OR = 0.779, p < 0.0001, respectively), and larger values for WTW, Astig, and J45 (OR = 1.277, OR = 1.482, OR = 1.1, all p < 0.0001) were obtained. All ocular measurements by both instruments showed positive correlations, with AXL demonstrating the strongest correlation (r = 0.9996, p < 0.0001). The intraclass correlation coefficients for AXL and CCT measured by both instruments was 0.999 and 0.988 (both p < 0.0001), and Bland-Altman plot showed 95% limits of agreement (LoA) of -0.078 to 0.11 mm and - 9.989 to 13.486 µm, respectively. The maximum absolute 95% LoA for LT, WTW, K1, K2, and J0 were relatively high, achieving 0.829 mm, 0.717 mm, 0.983 D, 0.948 D, and 0.632 D, respectively. CONCLUSIONS: In young patients with myopia, CCT and AXL measurements obtained with the Colombo IOL 2 and IOLMaster 700 were comparable. However, WTW, LT, corneal refractive power, and astigmatism values could not be used interchangeably in clinical practice.


Assuntos
Comprimento Axial do Olho , Biometria , Miopia , Humanos , Masculino , Biometria/métodos , Biometria/instrumentação , Comprimento Axial do Olho/patologia , Miopia/fisiopatologia , Miopia/diagnóstico , Feminino , Adulto , Adulto Jovem , Análise de Fourier , Tomografia de Coerência Óptica/métodos , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/patologia , Córnea/patologia , Córnea/diagnóstico por imagem , Refração Ocular/fisiologia
15.
Int Ophthalmol ; 44(1): 302, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38954134

RESUMO

PURPOSE: To compare early changes in the corneal biomechanical parameters after photorefractive keratectomy (PRK) and small incision lenticule extraction (SMILE) and their correlations with corneal shape parameters. METHODS: One hundred twenty four eyes received myopic PRK and SMILE for similar amounts of myopia. Corneal tomography with Pentacam HR, biomechanical parameters using Corvis ST, and Ocular Response Analyzer (ORA) were evaluated before and 2 weeks after surgery. The change in each parameter was compared between groups, while the difference in central corneal thickness and cornea-compensated intraocular pressure measured before and after surgery were considered as covariates. RESULTS: A significant reduction was seen in the corneal stiffness parameter at first applanation, and an increase in deformation amplitude ratio (DAR), and integrated inverse radius (IIR) in both groups after surgery (p < 0.001) Changes in DAR, and IIR were significantly greater in the SMILE than in the PRK group (p < 0.001) Corneal hysteresis (CH) and corneal resistance factor (CRF) decreased in both SMILE and PRK groups after surgery, (p < 0.001) with no statistically significant difference between groups (p > 0.05) Among new Corvis ST parameters, DAR showed a significant correlation with changes in Ambrosio relational thickness in both groups (p < 0.05). CONCLUSIONS: Both techniques caused significant changes in corneal biomechanics in the early postoperative period, with greater elastic changes in the SMILE group compared to the PRK group, likely due to lower tension in the SMILE cap and thinner residual stromal bed in SMILE. There were no differences in viscoelastic changes between them, so the lower CH may reflect the volume of tissue removed.


Assuntos
Córnea , Elasticidade , Miopia , Ceratectomia Fotorrefrativa , Humanos , Ceratectomia Fotorrefrativa/métodos , Miopia/cirurgia , Miopia/fisiopatologia , Córnea/cirurgia , Córnea/fisiopatologia , Córnea/diagnóstico por imagem , Feminino , Masculino , Adulto , Elasticidade/fisiologia , Fenômenos Biomecânicos , Adulto Jovem , Lasers de Excimer/uso terapêutico , Pressão Intraocular/fisiologia , Cirurgia da Córnea a Laser/métodos , Refração Ocular/fisiologia , Topografia da Córnea , Substância Própria/cirurgia , Período Pós-Operatório , Acuidade Visual/fisiologia , Estudos Prospectivos , Seguimentos
16.
Mol Vis ; 30: 150-159, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39076769

RESUMO

Purpose: While lacrimal gland removal is commonly used in animal models to replicate dry eye disease, research into systematically monitoring dry eye disease's longitudinal pathological changes is limited. In vivo confocal microscopy (Heidelberg Retina Tomograph 3 with a Rostock Cornea Module, Heidelberg Engineering Inc., Franklin, MA) can non-invasively reveal corneal histopathological structures. To monitor dry-eye-disease-related changes in corneal structures, we developed a precise monitoring method using in vivo confocal microscopy in a rat double lacrimal gland removal model. Methods: Five Sprague-Dawley rats (age 8-9 weeks, male) underwent double lacrimal gland removal. Modified Schirmer's tear test, blink tests, and in vivo confocal microscopy images were acquired pre-surgery and at 1, 2, and 4 weeks post-surgery. Three individual stromal nerves were selected per eye as guide images, and images of the corresponding sub-basal nerve plexus area were acquired via volume acquisition. The same area was re-imaged in subsequent weeks. Results: After double lacrimal gland removal, tear production was reduced by 60%, and the blink rate increased 10 times compared to pre-surgery. Starting from 1 week after surgery, in vivo confocal microscopy showed increased sub-basal nerve plexus nerve fiber density with inflammatory cell infiltration at the sub-basal nerve plexus layer and remained at an elevated level at 2 and 4 weeks post-surgery. Conclusions: We demonstrated that our precise monitoring method revealed detailed changes in the corneal nerves, the epithelium, and the stroma.


Assuntos
Córnea , Modelos Animais de Doenças , Síndromes do Olho Seco , Aparelho Lacrimal , Microscopia Confocal , Ratos Sprague-Dawley , Lágrimas , Animais , Microscopia Confocal/métodos , Síndromes do Olho Seco/patologia , Síndromes do Olho Seco/diagnóstico por imagem , Ratos , Masculino , Córnea/inervação , Córnea/patologia , Córnea/diagnóstico por imagem , Lágrimas/metabolismo , Aparelho Lacrimal/patologia , Aparelho Lacrimal/diagnóstico por imagem , Piscadela/fisiologia
17.
BMC Ophthalmol ; 24(1): 285, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39009964

RESUMO

AIM: This study aimed to differentiate moderate to high myopic astigmatism from forme fruste keratoconus using Pentacam parameters and develop a predictive model for early keratoconus detection. METHODS: We retrospectively analysed 196 eyes from 105 patients and compared Pentacam variables between myopic astigmatism (156 eyes) and forme fruste keratoconus (40 eyes) groups. Receiver operating characteristic curve analysis was used to determine the optimal cut-off values, and a logistic regression model was used to refine the diagnostic accuracy. RESULTS: Statistically significant differences were observed in most Pentacam variables between the groups (p < 0.05). Parameters such as the Index of Surface Variance (ISV), Keratoconus Index (KI), Belin/Ambrosio Deviation Display (BAD_D) and Back Elevation of the Thinnest Corneal Locale (B.Ele.Th) demonstrated promising discriminatory abilities, with BAD_D exhibiting the highest Area under the Curve. The logistic regression model achieved high sensitivity (92.5%), specificity (96.8%), accuracy (95.9%), and positive predictive value (88.1%). CONCLUSION: The simultaneous evaluation of BAD_D, ISV, B.Ele.Th, and KI aids in identifying forme fruste keratoconus cases. Optimal cut-off points demonstrate acceptable sensitivity and specificity, emphasizing their clinical utility pending further refinement and validation across diverse demographics.


Assuntos
Topografia da Córnea , Ceratocone , Fotografação , Curva ROC , Humanos , Ceratocone/diagnóstico , Feminino , Masculino , Estudos Retrospectivos , Adulto , Gana , Topografia da Córnea/métodos , Fotografação/métodos , Adulto Jovem , Adolescente , Córnea/patologia , Córnea/diagnóstico por imagem , Pessoa de Meia-Idade , Miopia/diagnóstico , Astigmatismo/diagnóstico , Acuidade Visual
18.
Int Ophthalmol ; 44(1): 237, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38902457

RESUMO

PURPOSE: Calculating the intraocular lens (IOL) in patients after corneal refractive surgery presents a challenge. Because an overestimation of corneal power in cases undergone this surgery leading to a subsequent under-correction of IOL power. However, recent advancements in technology have eliable measurement of total corneal power. The aim of this research was to assess the agreement in simulated keratometry (SimK) and total keratometry (TK) values between IOLMaster 700 and Pentacam AXL. METHODS: The study involved 99 patients (99 eyes) undergone small incision lenticule extraction (SMILE) surgery. Each patient underwent scans using IOL Master 700 and Pentacam AXL. The following parameters were recorded: SimK1, SimK2, Total K1 (TK1), and Total K2 (TK2) for IOLMaster 700; and SimK1, SimK2, True Net Power (TNP) K1, TNPK2, Total Corneal Refractive Power (TCRP) K1, and TCRP K2 for Pentacam AXL. Agreement between the two devices was evaluated using Bland-Altman plot, while paired t-test was utilized to compare any differences in the same parameter by both instruments. RESULTS: The results revealed a strong correlation between the two devices.Noticeable comparability was identified for all SimK variables. However, there were noticeable differences in TK measurements as well as TK1-TNPK1, TK2-TNP K2, TK1-TCRP K1, and TK2-TCRP K2 parameters when comparing the two devices. The IOLMaster 700 consistently measured steeper values than the Pentacam AXL, with significant and clinically relevant differences of 1.34, 1.37, 0.87, and 0.95 diopters, respectively. CONCLUSION: While there was a noticeable correlation between the IOLMaster 700 and Pentacam AXL in SimK measurements, a marked difference was noted in TK values. The two devices cannot be used interchangeably when quantifying TK values.


Assuntos
Córnea , Topografia da Córnea , Miopia , Refração Ocular , Humanos , Masculino , Feminino , Adulto , Córnea/cirurgia , Córnea/diagnóstico por imagem , Córnea/patologia , Refração Ocular/fisiologia , Topografia da Córnea/métodos , Miopia/cirurgia , Miopia/diagnóstico , Pessoa de Meia-Idade , Adulto Jovem , Lentes Intraoculares , Biometria/métodos , Biometria/instrumentação , Estudos Prospectivos , Reprodutibilidade dos Testes , Acuidade Visual , Cirurgia da Córnea a Laser/métodos
19.
Cesk Slov Oftalmol ; 80(Ahead of print): 1-12, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38925892

RESUMO

AIMS: To investigate the concordance between the corneal power determined by various approaches with two tomographers (MS-39® and Galilei G6®) and the clinical history method (CHM) in patients undergoing photorefractive surgery with excimer laser for myopic errors. MATERIAL AND METHODS: Prospective cohort study. Patients undergoing keratorefractive surgery, and having pre- and postoperative keratometries, and tomographies, were included. RESULTS: In 90 eyes, the differences in the power estimated by the CHM and the one determined by four approaches with the corneal tomographers, which included measurements of the posterior cornea, did not show statistically significant differences in their averages. However, the 95% limits of agreement were very wide. After obtaining regression formulas to adjust the values of these four variables, the results of the agreement analysis were similar. CONCLUSION: Although certain values either directly determined or derived from measurements with the Galilei® and MS-39®corneal tomographers, approximated the estimated value of postoperative corneal power according to the CHM, due to the amplitude of their limits of agreement, these calculations must be taken with care, because they may not be accurate in a given eye.


Assuntos
Córnea , Miopia , Humanos , Córnea/diagnóstico por imagem , Córnea/cirurgia , Córnea/patologia , Córnea/fisiopatologia , Miopia/cirurgia , Miopia/fisiopatologia , Miopia/diagnóstico por imagem , Adulto , Estudos Prospectivos , Masculino , Feminino , Ceratectomia Fotorrefrativa , Adulto Jovem , Topografia da Córnea , Lasers de Excimer/uso terapêutico , Refração Ocular
20.
Cesk Slov Oftalmol ; 80(Ahead of print): 1-5, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38925898

RESUMO

AIM: The primary aim of this study is to evaluate the repeatability of noninvasive break-up time (NIBUT) measurement by keratograph when it is determined from one, two or three partial measurements, and to recommend a suitable methodology for practice. Another goal is to verify that repeated measurements do not affect the measured value. MATERIAL AND METHODS: Thirty-eight healthy volunteers (30 women and 8 men) aged between 19 and 50 years old were included in the study, in which only one eye of each volunteer was measured. The study was designed as a prospective one. Each subject adapted to the local conditions of the laboratory for 15 minutes and subsequently underwent two series of NIBUT measurements (test, retest) on an OCULUS 3 Keratograph. The minimum time interval between the two series was 10 minutes, in which each series contained three partial measurements approximately 3 three measurements in the given series. Repeatability was assessed by a Bland-Altman analysis and expressed as a repeatability coefficient. In every case, only the time of the first break-up of the tear film was monitored. RESULTS: The statistical analysis did not show statistically significant differences both between partial measurements of NIBUT in the individual series (p = 0.92, p = 0.81) and when comparing all six measurements (p = 0.95). The mean values of the partial measurements ranged from 13.6 s to 14.4 s. The repeatability coefficients were found to be 15.0 s, 12.1 s and 10.0 s for methodologies A, B and C, respectively. A supplementary analysis for 12 eyes with low NIBUT (< 10 s) showed statistically significantly better repeatability in this group, with coefficients of 7.0 s (methodology A), 6.0 s (B) and 4.6 s (C). CONCLUSION: Determination of NIBUT from three consecutive measurements (with a sufficient interval of ideally a few minutes) significantly improves repeatability. Such repeated NIBUT measurements do not have a significant effect on the measured value. The mentioned methodology for measuring NIBUT on a keratograph can be recommended for use in practice.


Assuntos
Lágrimas , Humanos , Adulto , Feminino , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem , Lágrimas/química , Técnicas de Diagnóstico Oftalmológico/instrumentação , Córnea/diagnóstico por imagem , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA