Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.274
Filtrar
3.
Indian J Ophthalmol ; 72(9): 1372-1373, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38990616

RESUMO

Intumescent cataract can be a challenge even for an experienced surgeon, particularly for creating a continuous curvilinear capsulorhexis (CCC) because of increased endolenticular pressure. CCC in white intumescent cataract is associated with increased risk of extension of rhexis margin leading to radial tear or biradial extension causing "Argentinian flag sign" and associated complications. We describe a novel technique for CCC, in which we manipulate the vector forces acting in creating a capsulorhexis. After making a mini CCC, a flap is raised and then inverted under the rhexis margin and CCC is done by keeping the flap inverted using shearing and tearing forces, keeping the direction of force down and toward the center in a curvilinear fashion. It is a new surgical technique to perform a successful and safer CCC in intumescent cataract with consistent outcome.


Assuntos
Capsulorrexe , Catarata , Retalhos Cirúrgicos , Humanos , Capsulorrexe/métodos , Catarata/complicações , Acuidade Visual/fisiologia , Cápsula do Cristalino/cirurgia , Facoemulsificação/métodos , Masculino
4.
J Cataract Refract Surg ; 50(9): 963-969, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38758190

RESUMO

PURPOSE: To develop a chemical method that makes porcine lens anterior capsule resemble human lens anterior capsule in tear force and perforating force. SETTING: Beijing Tongren Hospital, Beijing, China. DESIGN: Experimental study. METHODS: Porcine eyes were divided into groups, and reagents (0.9% physiological saline, 0.1% sodium hypochlorite, 0.3% sodium hypochlorite, and 0.5% sodium hypochlorite) were injected into the anterior chamber, respectively, recorded as Groups A, B, C, and D, respectively. A senior physician collected each group of anterior capsules after performing continuous circular capsulorhexis and assessing the anterior capsule's tearing and perforation forces. An additional group, which consisted of human lens anterior capsules taken in the operating room from patients with cataract, recorded as Group E. A tensile system was used to measure each sample's tensile force. RESULTS: A significant difference was found between Group A and any other group in maximum tensile force and average tensile force in both transverse and longitudinal directions. No significant difference was found between any 2 groups from Group B to Group E. According to the surgeon's assessment, the tear force characteristic of the porcine lens anterior capsule treated with 0.1%, 0.3%, and 0.5% sodium hypochlorite solution was similar to that of the human lens anterior capsule. CONCLUSIONS: Porcine lens capsule treated using this method can be used for training of new surgeons. The porcine lens anterior capsule treated with 0.5% sodium hypochlorite, which results showed most resembled human lens anterior capsule, can be used for robotic training.


Assuntos
Capsulorrexe , Cápsula do Cristalino , Animais , Suínos , Humanos , Capsulorrexe/métodos , Cápsula do Cristalino/cirurgia , Hipoclorito de Sódio/farmacologia , Resistência à Tração , Cápsula Anterior do Cristalino/cirurgia
5.
Indian J Ophthalmol ; 72(9): 1355-1358, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38767556

RESUMO

The present article describes a novel surgical technique of a primary mini-capsulorhexis in midperiphery to minimize surgical complications in white intumescent cataracts. Patients with white mature cataracts with a convex anterior capsule or swollen lens fibers were selected. An initial puncture was made 3-4 mm away from the center, in the midperipheral anterior capsule, with a conventional cystitome. A mini-capsulorhexis (2-2.5 mm) was created. Loose cortical matter and fluidic contents were aspirated to reduce the intralenticular pressure. Two cuts were made at the margin of the mini-capsulorhexis, and an adequately sized secondary rhexis was completed, after which phacoemulsification was done. A circular curvilinear capsulorhexis was successfully achieved in all cases, including those with a small pupil. Rhexis could be completed in a patient where an initial extension occurred due to head movement. This refined technique aims to enhance the safety and precision of capsulorhexis in intumescent cataracts, thereby reducing the risk of complications such as the Argentinian flag sign. Further exploration and validation of this approach through clinical trials are warranted to establish its efficacy and safety profile.


Assuntos
Capsulorrexe , Catarata , Facoemulsificação , Humanos , Facoemulsificação/métodos , Capsulorrexe/métodos , Catarata/complicações , Feminino , Acuidade Visual , Masculino , Idoso , Pessoa de Meia-Idade
6.
J Cataract Refract Surg ; 50(5): 498-504, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38651697

RESUMO

PURPOSE: To compare 3 capsulotomy centration methods. SETTING: Private clinic, Zlin, Czech Republic. DESIGN: Prospective, consecutive case series. METHODS: 180 eyes undergoing cataract surgery had anterior capsule staining with microfiltered 0.4% trypan blue solution before selective laser capsulotomy. The first 60 eyes (Group 1) had mydriatic dilated pupil centered capsulotomies. The next 60 eyes (Group 2) were centered on the trypan blue central landmark (TCL). The final 60 capsulotomies (Group 3) were centered on the patient fixated coaxial Purkinje reflex (CPR). Measurements between key anatomical landmarks and the TCL, CPR capsulotomies, and implanted intraocular lens (IOL) center were made. RESULTS: The TCL, observed in >94% of eyes in the study, coincided with the CPR with a displacement of <0.1 ± 0.1 mm. Group 1 capsulotomies were noticeably decentered on the IOLs by 0.3 ± 0.2 mm. The Group 2 symmetrical IOL relationship was maintained with a decentration of 0.15 ± 0.1 mm. Group 3 had a similar decentration with the IOLs with 0.15 ± 0.1 mm. Verification with IOLMaster 700 data and CALLISTO Eye System showed that the CPR and the TCL were coincident with the measured visual axis. CONCLUSIONS: The clearly visible TCL served as an alternate landmark to the patient fixated CPR, and being on the anterior capsule was not sensitive to tilt. Further patient compliance was not required. Both were superior to dilated pupil centration, to achieve symmetric IOL coverage. This has application for both capsulotomies and capsulorhexes.


Assuntos
Capsulorrexe , Corantes , Facoemulsificação , Azul Tripano , Humanos , Capsulorrexe/métodos , Estudos Prospectivos , Idoso , Corantes/administração & dosagem , Implante de Lente Intraocular , Masculino , Feminino , Pessoa de Meia-Idade , Cápsula Anterior do Cristalino/cirurgia , Pontos de Referência Anatômicos , Cápsula do Cristalino/cirurgia , Idoso de 80 Anos ou mais
7.
BMJ Case Rep ; 17(1)2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38191223

RESUMO

Anterior capsular contraction syndrome is an uncommon but well-known complication associated with continuous curvilinear capsulorhexis performed during cataract surgery. It remains asymptomatic unless the constriction progresses to involve the visual axis or causes late intraocular lens-related complications. A male patient in his 50s presented with severely decreased vision in his right eye 2 years after uneventful cataract surgery. Slit-lamp biomicroscopy revealed capsular phimosis and a dense, central, fibrous plaque with total occlusion of the anterior capsulorhexis opening. Neodymium-doped yttrium aluminium garnet laser anterior capsulotomy and vitrectorhexis were attempted, but proved ineffective. Surgical excision with manual cutting of the fibrotic membrane was performed, successfully clearing the visual axis and restoring vision.


Assuntos
Extração de Catarata , Catarata , Oftalmologia , Humanos , Masculino , Olho , Capsulorrexe , Síndrome
8.
J Cataract Refract Surg ; 50(6): 599-604, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38270489

RESUMO

PURPOSE: To investigate the effect of anterior capsule polishing on postoperative capsule opacification and capsular bend in patients with age-related cataract displaying normal axial length. SETTING: Eye Hospital of Wenzhou Medical University at Hangzhou. DESIGN: Prospective self-controlled trial. METHODS: Patients with age-related cataracts aged 56 to 84 years displaying normal axial length were enrolled. Before surgery, a coin-toss method was used to randomly select 1 eye for intraoperative 360 degrees anterior capsule polishing (polishing group); the contralateral eye received no treatment (control group). Capsular bend index (CBI), anterior capsule opacification (ACO), posterior capsule opacification (PCO), and anterior capsule opening area (ACOA) were recorded at 1 week, 1 month, 3 months, 6 months, and 12 months postoperatively using swept-source optical coherence tomography and slitlamp examination. RESULTS: 21 patients (42 eyes) were enrolled. Within-group comparisons showed that both groups had significant differences in CBI between 1 week and 1 month postoperatively, and between 6 months and 12 months postoperatively ( P < .05). Between-group comparisons revealed a significant difference in CBI at 1 week postoperatively ( P < .05); at 12 months postoperatively, there was a significant difference in ACOA ( P < .05). There were no significant between-group differences regarding ACO or PCO at any timepoint ( P > .05). CONCLUSIONS: For patients with age-related cataracts and normal axial length, 360 degrees anterior capsule polishing can delay early capsular bag deformation without increasing the risks of ACO and PCO. This approach can also limit contraction of the anterior capsule opening.


Assuntos
Cápsula Anterior do Cristalino , Opacificação da Cápsula , Facoemulsificação , Tomografia de Coerência Óptica , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cápsula Anterior do Cristalino/cirurgia , Opacificação da Cápsula/prevenção & controle , Capsulorrexe/métodos , Catarata , Cápsula do Cristalino/cirurgia , Cápsula do Cristalino/patologia , Implante de Lente Intraocular , Facoemulsificação/métodos , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Tomografia de Coerência Óptica/métodos , Acuidade Visual/fisiologia
9.
Indian J Ophthalmol ; 72(Suppl 2): S312-S313, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38271429

RESUMO

We describe a novel technique that uses precision pulse capsulotomy (PPC) to perform a secondary capsulotomy for the management of anterior capsule contraction syndrome (ACCS), a condition that comprises a late complication after cataract surgery and intraocular lens (IOL) implantation. Micropulse secondary capsulotomy offers a controlled and safe approach for patients with severe anterior capsule contraction syndrome and may be considered as an alternative surgical technique.


Assuntos
Opacificação da Cápsula , Lentes Intraoculares , Facoemulsificação , Humanos , Capsulorrexe/métodos , Implante de Lente Intraocular/métodos , Opacificação da Cápsula/diagnóstico , Opacificação da Cápsula/cirurgia , Tecnologia , Facoemulsificação/métodos
10.
Indian J Ophthalmol ; 72(2): 162-173, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38273682

RESUMO

The Argentinian flag sign (AFS) is a feared complication during cataract extraction. Intralenticular pressures, especially excessive posterior pressure, have been identified as potential mechanisms for capsular stress and tearing associated with AFS. Capsular tension is created by positive intralenticular pressures, which cause the irido-lens diaphragm to move anteriorly once the manual capsulorhexis has been initiated. This tension can cause inadvertent tears that self-propagate to the lens equator, causing an AFS, among other intraoperative complications. Thus, this review highlights the importance of identifying intumescent cataracts as well as a combination of techniques to relieve intracapsular pressures needed to prevent AFS. However, some instances of anterior capsular tears are unavoidable. Therefore, focus will also be placed on techniques during cataract extraction used to manage anterior capsular tears, mitigating extension to the posterior capsule.


Assuntos
Extração de Catarata , Catarata , Cápsula do Cristalino , Facoemulsificação , Humanos , Facoemulsificação/métodos , Extração de Catarata/métodos , Capsulorrexe/métodos , Cápsula do Cristalino/cirurgia , Catarata/etiologia , Catarata/complicações
11.
Retina ; 44(6): 1107-1110, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38176001

RESUMO

PURPOSE: The intraocular lens blocking technique described for the removal of intraocular foreign bodies emerged as a result of an effort to prevent the foreign body from being retracted into the posterior segment because of the resistance encountered while removing it from the corneal incision. However, in the technique described, in addition to the difficulty of the surgical procedure, the new concern is to create a posterior capsulorhexis according to the size of the foreign body and to pass the foreign body through the capsulorhexis. METHODS: Here, the authors describe a new approach to the intraocular lens blocking technique. In this approach, the intraocular foreign body, which is held with intraocular forceps without any opening in the posterior capsule, is held in a perpendicular position to the long axis, lifted directly into the anterior chamber, and safely removed from the front of the monoblock foldable intraocular lens. RESULTS: In all patients treated with this approach, IOFBs were successfully removed without intraoperative or postoperative complications, and postoperative intraocular lens centralization was achieved in all patients. CONCLUSION: This approach may provide practicality to the intraocular lens blocking technique.


Assuntos
Capsulorrexe , Corpos Estranhos no Olho , Lentes Intraoculares , Humanos , Corpos Estranhos no Olho/cirurgia , Corpos Estranhos no Olho/diagnóstico , Capsulorrexe/métodos , Masculino , Feminino , Adulto , Ferimentos Oculares Penetrantes/cirurgia , Pessoa de Meia-Idade , Adulto Jovem
12.
J Cataract Refract Surg ; 50(2): 146-152, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37816250

RESUMO

PURPOSE: To report how to manage posterior capsule abnormalities (PCAs) in pediatric cataracts and evaluate the influence of PCAs during intraocular lens (IOL) optic implantation in Berger space surgeries. SETTING: Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China. DESIGN: Retrospective case series study. METHODS: Pediatric patients with PCAs who underwent cataract surgery were evaluated. A video-based analysis of the surgical interventions included the type of crystalline lens opacification, types and management of PCAs, complications during primary posterior continuous curvilinear capsulorhexis (PCCC), need for anterior vitrectomy (AV), and feasibility of IOL optic capture. RESULTS: There were 227 pediatric cataract surgeries performed during the study period, and 76 eyes of 66 children with PCAs were evaluated (33.5%, 76/227). Unilateral cataract with PCAs were found in 50 eyes (22.0%, 50/227) and bilateral were found in 26 eyes (11.5%, 26/227). The PCAs were posterior capsule plaque (19.8%, 45/227), posterior capsule defect (6.2%, 14/227), posterior lenticonus (3.1%, 7/227), and persistent fetal vasculature (4.4%, 10/227). In the PCA cases, primary PCCC was successful in 44.7% of the cases (34/76). An unplanned AV during the surgeries was performed in 47.4% (36) of the 76 eyes. IOL optic implantation in Berger space was achieved in 63.2% of the eyes (48/76). CONCLUSIONS: PCAs are often encountered during pediatric cataract surgeries, especially in unilateral cases. The presence of PCAs may complicate a primary PCCC procedure, resulting in an unplanned AV in some cases. IOL optic implantation in Berger space can also be performed fortunately with well-designed and skilled operation.


Assuntos
Extração de Catarata , Catarata , Cápsula do Cristalino , Cristalino , Lentes Intraoculares , Criança , Humanos , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Lentes Intraoculares/efeitos adversos , Cápsula do Cristalino/cirurgia , Extração de Catarata/efeitos adversos , Catarata/etiologia , Capsulorrexe/métodos , Complicações Pós-Operatórias/cirurgia
13.
Indian J Ophthalmol ; 72(4): 578-581, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38146976

RESUMO

PURPOSE: To compare the histomorphologic changes on the anterior lens capsule by both epithelial and basement membrane side staining to those of only basement membrane side staining of the anterior lens capsule with Trypan Blue (TB). METHODS: A cross-sectional study was done on 72 samples from patients who underwent cataract surgery between April 2021 and September 2022. After capsulorhexis of the TB-stained capsule, it was made into two halves externally and one half labeled as controls (sample A). The other half was immediately stained further with TB on the epithelial side and was taken as cases (sample B). Samples were analyzed for lens epithelial cells and basement membrane changes. RESULTS: The loss of intactness of lens epithelial cells, partial or complete detachment of lens epithelial cells, degeneration of lens epithelial cells, and basement edema were significantly higher in cases compared to controls, whereas intactness of the basement membrane did not show any statistical significance between the two groups. There was a statistically significant decrease in cell density in cases compared to controls. CONCLUSION: Staining the epithelial side of the capsular bag with TB is more detrimental to lens epithelial cells and paves the way for a further study of staining the capsular bag before intra-ocular lens implantation to reduce the incidence of posterior capsule opacification.


Assuntos
Catarata , Cápsula do Cristalino , Facoemulsificação , Humanos , Azul Tripano , Cápsula do Cristalino/cirurgia , Membrana Basal , Corantes/farmacologia , Estudos Transversais , Coloração e Rotulagem , Capsulorrexe
14.
Indian J Ophthalmol ; 72(1): 51-55, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38131569

RESUMO

PURPOSE: The efficacy of posterior optic capture (POC) in reducing posterior capsule opacification (PCO) in pediatric cataract is well recognized. The purpose of this paper was to identify the surgical challenges when attempting this technique and highlight the etiquettes to follow when performing this maneuver. METHODS: Prospective observational noncomparative case series. Children diagnosed with congenital or developmental cataracts undergoing cataract surgery and primary IOL implantation with posterior optic capture (and no anterior vitrectomy) from June 2017 to April 2022 at a tertiary care referral institute were included. Records of all intraoperative findings and postoperative complications until the last follow-up were noted. RESULTS: Posterior optic capture was attempted in 53 eyes of 49 children aged 2.4 ± 1.98 years. The mean follow-up of the patients was 16.5 ± 14.2 months (range 6 months-5 years). Successful POC could be performed in 46 eyes (86.8%). Two eyes developed posterior capsular opacification at the last follow-up. In eyes where POC could not be performed, five of these (83%) were children below 12 months of age with half of them having a preexisting posterior capsular defect. CONCLUSION: Posterior optic capture is technically challenging with a steep learning curve that can be mastered over time. Adequate relative sizing of the anterior and posterior capsulorhexis is important. Caution is advised when using this technique in infants and in cases with posterior capsular defects.


Assuntos
Extração de Catarata , Catarata , Cápsula do Cristalino , Lentes Intraoculares , Humanos , Lactente , Capsulorrexe/métodos , Catarata/etiologia , Extração de Catarata/efeitos adversos , Cápsula do Cristalino/cirurgia , Implante de Lente Intraocular/métodos , Lentes Intraoculares/efeitos adversos , Complicações Pós-Operatórias/cirurgia , Vitrectomia/métodos , Pré-Escolar
15.
Indian J Ophthalmol ; 72(1): 73-75, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38131573

RESUMO

We described a novel "flow capsulorhexis" technique in white and hypermature cataracts and compared it with the standard "needle decompression capsulorhexis" technique. Six hundred and eight eyes of 420 patients with intumescent or non-intumescent mature white cataracts who had undergone phacoemulsification or manual small incision cataract surgery with "flow capsulorhexis" (Group 1) or "needle decompression capsulorhexis" (Group 2) were assessed. The mean continuous curvilinear capsulorhexis (CCC) completion time was 6.6 ± 3.4 seconds in Group 1 and 10.4 ± 4.2 seconds in Group 2 (P < 0.001). The mean number of times for an ophthalmic viscosurgical device (OVD) supplement was 0.4 ± 0.2 and 1.8 ± 0.8 in Group 1 and Group 2, respectively (P < 0.001). CCC success rate was 95.8% in Group 1 and 87.2% in Group 2 (P = 0.001). The new technique was observed to have better outcomes in terms of surgical time, OVD supplement times, and success rate than the standard needle decompression technique.


Assuntos
Extração de Catarata , Catarata , Cápsula do Cristalino , Facoemulsificação , Humanos , Capsulorrexe/métodos , Cápsula do Cristalino/cirurgia , Facoemulsificação/métodos
16.
Zhonghua Yan Ke Za Zhi ; 59(12): 995-1002, 2023 Dec 11.
Artigo em Chinês | MEDLINE | ID: mdl-38061900

RESUMO

Objective: To investigate the disparity between the set value of the capsulorhexis ring diameter in ophthalmic surgical navigation systems and the actual capsulorhexis ring diameter projected onto the lens surface. Methods: It was a cross-sectional study. Based on the Gullstrand eye model, the theoretical diameter of the capsulorhexis ring projected onto the lens plane through the cornea was calculated using the law of refraction in the Callisto Eye System. When the anterior chamber depth (ACD) ranged from 2.0 to 4.0 mm and the corneal curvature ranged from 40.00 to 48.00 D, the capsulorhexis ring diameters were calculated after projecting capsulorhexis rings with set diameters of 5.5 mm and 6.0 mm onto the lens plane. Additionally, 40 patients (40 eyes) aged 40 to 85 years who underwent cataract phacoemulsification combined with intraocular lens implantation at the Sixth People's Hospital of Shanghai Jiao Tong University School of Medicine were selected to validate the theoretical calculations. Among them, 15 were male, and 25 were female, and they were divided into three groups based on the ACD: group A (13 eyes) with ACD<3.0 mm; group B (16 eyes) with 3.0 mm≤ACD<3.5 mm; group C (11 eyes) with ACD≥3.5 mm. One week after surgery, anterior segment images of the eyes were taken, and the actual capsulorhexis ring diameter was measured using the Photoshop image processing software and compared with the set and calculated values. Results: When the capsulorhexis ring diameters were set at 5.5 mm and 6.0 mm and the corneal curvature was calculated based on the Gullstrand Eye model at 43.05 D, a linear negative correlation was found between ACD and the capsulorhexis ring diameter projected onto the lens plane (P<0.001). When the ACD was set at 2.5, 3.0, and 3.5 mm, and the capsulorhexis ring diameters were set at 5.5 and 6.0 mm, a linear negative correlation was observed between corneal curvature and the capsulorhexis ring diameter projected onto the lens plane (P<0.001). When the capsulorhexis ring diameter was set at 5.5 mm and the patient ACD and corneal curvature data were used for calculations, the capsulorhexis ring diameters projected onto the lens plane for groups A, B, and C were (5.09±0.05) mm, (4.97±0.05) mm, and (4.91±0.07) mm, respectively. When the capsulorhexis ring diameter was set at 6.0 mm, they were (5.56±0.05) mm, (5.44±0.05) mm, and (5.37±0.08) mm, respectively. One week after surgery, the actual measurements of capsulorhexis ring diameters for groups A, B, and C were (5.44±0.20) mm, (5.27±0.28) mm, and (5.25±0.41) mm, respectively, and the differences compared to the calculated values were not statistically significant (all P>0.05), but the differences compared to the set values were statistically significant (all P<0.001). Conclusion: The capsulorhexis ring diameter projected onto the lens surface by the Callisto Eye system was reduced by 7.33% to 10.48% compared to the set value, and the degree of reduction increased with the increase of ACD and corneal curvature.


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Masculino , Feminino , Capsulorrexe/métodos , Implante de Lente Intraocular , Estudos Transversais , China , Facoemulsificação/métodos
17.
Medicine (Baltimore) ; 102(45): e35762, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37960729

RESUMO

To assess the efficiency and safety of capsulorhexis with CAPSULaser in comparison with standard capsulorhexis performed manually by emerging and established surgeons. Specialized Eye Hospital-Varna Bulgaria. Prospective, randomized, non-masked study. Patients were randomized to the M group (manual CCC), L group (laser CCC), and 2 surgeons. The manual CCC was targeted at 5.5 mm. The laser CCC was sized at 5.3 mm and measured with the same caliper device during photomicroscopy. The inclusion criteria were otherwise healthy eyes with cortical, nuclear, or subcapsular cataracts of any maturity with a biomicroscopically deep anterior chamber and preoperative pupil wider than 6.5 mm. The surgical time was measured for the entire procedure and only for capsulotomy. Sixty eyes of 60 patients, aged 65.8 ±â€…11 years, were prospectively recruited. Two surgeons (one with 3 years and one with 30 years of experience) performed the same types and number of procedures. The experienced surgeon was 2 times faster when performing manual capsulorhexis, but the time for CAPSULaser was almost the same. The size of the "laser" CCC was planned to be 5.3 and ended up with a minimum of 5.4 in 4 weeks; however, no lens prolapse from the CCC was observed. Utilization of the CAPSULaser in cataract surgery is easy and achievable for surgeons at any stage of their careers and provides controlled, well-centered capsulorhexis with no more adverse events than conventional surgery. The limitations are the requirement for a minimal pupil size of 6 mm, a deep anterior chamber, and a transparent cornea.


Assuntos
Extração de Catarata , Catarata , Facoemulsificação , Cirurgiões , Humanos , Capsulorrexe/métodos , Catarata/etiologia , Extração de Catarata/métodos , Facoemulsificação/métodos , Estudos Prospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais
18.
Indian J Ophthalmol ; 71(10): 3412-3414, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37787245

RESUMO

We describe a technique of scleral IOL fixation and optic centration of in the capsular bag subluxated IOL in a patient of "dead bag syndrome." A 29-year-old male diagnosed case of thalassemia presented with painless progressive diminution of vision in the left eye following uncomplicated sequential phacoemulsification in both eyes 15 years back. The right eye revealed completely centered IOL with significant amount of anterior capsular opacification (ACO), while the left eye revealed inferior subluxation of the IOL within capsular bag. The capsular bag was dilated, diaphanous with clear anterior and posterior capsule without any evidence of capsular fibrosis or opacification. Thus, a diagnosis of "dead bag syndrome" was made. The haptics were sutured to sclera (Hoffman's pockets) using two loops of 9-0 polypropylene, passed anterior and posterior to IOL haptics within the capsular bag. Postoperatively, the patient had a vision of 20/40 with a centered intraocular lens.


Assuntos
Cápsula do Cristalino , Lentes Intraoculares , Facoemulsificação , Masculino , Humanos , Adulto , Implante de Lente Intraocular/métodos , Cápsula do Cristalino/cirurgia , Lentes Intraoculares/efeitos adversos , Olho Artificial , Capsulorrexe/métodos
19.
Int Ophthalmol ; 43(12): 4759-4771, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37731157

RESUMO

PURPOSE: To evaluate the effect of primary posterior continuous curvilinear capsulorrhexis (PPCCC) on the positional stability of IOLs. METHODS: This study is a prospective intra-individual comparative randomized controlled trial including 31 patients (62 eyes). Eyes of the same patient were randomly assigned to the PPCCC group (18 right eyes and 13 left eyes) or group without PPCCC (NPCCC group). Eyes in both groups were implanted with a one-piece foldable hydrophobic acrylic IOL via routine cataract surgery. Patients in the PPCCC group underwent additional manual PPCCC before IOL implantation. Examinations were performed 1 day, 1 week, 1 month and 3 months postoperatively. IOL tilt (x, y), decentration (x, y), anterior chamber depth (z) and refractive prediction error data were collected and analyzed with Pentacam. RESULTS: Postoperatively, the range of IOL position change over 3 months in PPCCC group was comparable to NPCCC group, which indicated smaller value in every tilt and decentration index. PPCCC eyes showed comparable tilt and decentration with NPCCC eyes in this study endpoint: mean tilt (x, y), decentration (x, y) and anterior chamber depth (ACD) were 1.04 ± 0.56°, 0.90 ± 0.64°, 0.239 ± 0.140 mm, 0.233 ± 0.133 mm and 4.01 ± 0.32 mm, respectively, in the PPCCC group vs. 1.09 ± 0.76°, 1.10 ± 0.82°, 0.252 ± 0.153 mm, 0.244 ± 0.155 mm and 4.01 ± 0.38 mm, respectively, in the NPCCC group. Refractive prediction error in the PPCCC group demonstrated a mild hyperopic shift vs. the NPCCC group (0.13 ± 0.50 vs. 0.05 ± 0.39; p = 0.208), and corrected distance visual acuity (CDVA) did not differ between the two groups (0.027 ± 0.014 vs. 0.059 ± 0.185; p = 0.377). CONCLUSIONS: Comparable IOL tilt, decentration, ACD and refractive prediction error were observed in PPCCC eyes with that underwent routine cataract surgery. Little IOL position fluctuation and good visual acuity were shown in PPCCC group over time. TRAIL REGISTRATION: The study was registered at the Chinese Clinical Trial Register Center on May 27th, 2020 (protocol code ChiCTR2000033304, 27/05/2020).


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Capsulorrexe/métodos , Implante de Lente Intraocular , Estudos Prospectivos
20.
Indian J Ophthalmol ; 71(9): 3255-3258, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37602617

RESUMO

A well-centered, adequately sized continuous curvilinear capsulorhexis (CCC) is a prerequisite for successful cataract surgery. A perfect capsulorhexis ensures safe and effective performance of various steps of surgery as well as a correctly positioned intraocular lens (IOL) with optimal rotational stability. Ganesh and Grewal (GG) cystitome maker is a step toward standardizing the creation of a cystitome to reduce variations and complications associated with the crucial step of CCC in cataract surgery. We conducted a study to measure the repeatability and precision of cystitomes made by the GG cystitome maker versus those made manually with a needle holder. The results showed that the cystitomes made with GG cystitome maker had a lesser degree of variation. This indicates a more repeatable cystitome, which will inadvertently help in reducing the error caused by the instrument in making a good CCC during cataract surgery.


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Humanos , Capsulorrexe , Olho Artificial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA