Resultados 1 - 20 de 53
Filtrar
1.
Viruses ; 16(5)2024 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-38793553

RESUMO

DNA assays for viral load (VL) monitoring are key tools in the management of immunocompromised patients with cytomegalovirus (CMV) or Epstein-Barr virus (EBV) infection. In this study, the analytical and clinical performances of the NeuMoDx™ CMV and EBV Quant Assays were compared with artus CMV and EBV QS-RGQ Kits in a primary hospital testing laboratory. Patient plasma samples previously tested using artus kits were randomly selected for testing by NeuMoDx assays. The NeuMoDx CMV Quant Assay and artus CMV QS-RGQ Kit limits of detection (LoDs) are 20.0 IU/mL and 69.7 IU/mL, respectively; 33/75 (44.0%) samples had CMV DNA levels above the LoD of both assays. The Pearson correlation coefficient was 0.9503; 20 samples (60.6%) had lower NeuMoDx CMV quantification values versus the artus kit. The LoD of the NeuMoDx EBV Quant Assay and artus EBV QS-RGQ Kit are 200 IU/mL and 22.29 IU/mL, respectively; 16/75 (21.3%) samples had EBV DNA levels above the LoD of both assays. The Pearson correlation coefficient was 0.8990. EBV quantification values with the NeuMoDx assay were higher versus the artus kit in 15 samples (93.8%). In conclusion, NeuMoDx CMV and EBV Quant Assays are sensitive and accurate tools for CMV and EBV DNA VL quantification.


Assuntos
Citomegalovirus , Herpesvirus Humano 4 , Carga Viral , Virologia , Herpesvirus Humano 4/fisiologia , Citomegalovirus/fisiologia , Carga Viral/instrumentação , Carga Viral/métodos , Virologia/instrumentação , Virologia/métodos , Limite de Detecção , Infecções por Citomegalovirus/sangue , Infecções por Citomegalovirus/virologia , Infecções por Vírus Epstein-Barr/sangue , Infecções por Vírus Epstein-Barr/virologia , Técnicas de Laboratório Clínico/instrumentação , Técnicas de Laboratório Clínico/métodos , Técnicas de Laboratório Clínico/normas , Humanos
2.
Viruses ; 13(8)2021 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-34452483

RESUMO

Cytomegalovirus (CMV) reactivations represent a significant morbidity and mortality problem in transplant patients. Reliable and rapid measurement of CMV viral load is a key issue for optimal patient management. We report here the evaluation of NeuMoDx™ (Qiagen) in a routine hospital setting (University Hospitals of Marseille, France) in comparison with our classical reference technique R-GENE. During one month, 719 CMV viral loads from 507 patients were measured in parallel in both techniques. Using the ROC (receiver operating characteristic) curve and our biological experience we suggest that values <52 IU/mL (geometric mean) correspond to negative samples, values >140 IU/mL (Fowlkes-Mallows index) correspond to quantifiable positive results and values ranging from 52 to 140 IU/mL represent non-quantifiable positive results. Follow-up of 15 transplant patients who developed CMV reactivation during the study showed that NeuMoDx™ provided higher viral load measurement during the first two weeks of follow-up for three patients. These important intra-individual variations resulted in a significant median increase considering the whole data set (6.7 points of difference expressed as a percentage of the initial viral load). However, no difference between the two techniques was noticeable after two weeks of treatment. Subsequent to this first study we conclude that NeuMoDx™, used with optimized logistics and an adapted threshold, allows a rapid CMV viral load measurement and that its use does not lead to any difference in patient management compared to the reference technique R-GENE®.


Assuntos
Automação Laboratorial/normas , Infecções por Citomegalovirus/virologia , Citomegalovirus/genética , DNA Viral/genética , Transplantados/estatística & dados numéricos , Carga Viral/instrumentação , Automação Laboratorial/instrumentação , Automação Laboratorial/métodos , Citomegalovirus/isolamento & purificação , Infecções por Citomegalovirus/sangue , Infecções por Citomegalovirus/diagnóstico , Retroalimentação , França , Humanos , Laboratórios Clínicos , Infecção Latente/virologia , Estudos Prospectivos , Carga Viral/métodos , Carga Viral/estatística & dados numéricos
3.
Cell ; 184(2): 323-333.e9, 2021 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-33306959

RESUMO

The December 2019 outbreak of a novel respiratory virus, SARS-CoV-2, has become an ongoing global pandemic due in part to the challenge of identifying symptomatic, asymptomatic, and pre-symptomatic carriers of the virus. CRISPR diagnostics can augment gold-standard PCR-based testing if they can be made rapid, portable, and accurate. Here, we report the development of an amplification-free CRISPR-Cas13a assay for direct detection of SARS-CoV-2 from nasal swab RNA that can be read with a mobile phone microscope. The assay achieved ∼100 copies/µL sensitivity in under 30 min of measurement time and accurately detected pre-extracted RNA from a set of positive clinical samples in under 5 min. We combined crRNAs targeting SARS-CoV-2 RNA to improve sensitivity and specificity and directly quantified viral load using enzyme kinetics. Integrated with a reader device based on a mobile phone, this assay has the potential to enable rapid, low-cost, point-of-care screening for SARS-CoV-2.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , Telefone Celular/instrumentação , Imagem Óptica/métodos , RNA Viral/análise , Carga Viral/métodos , Animais , Teste de Ácido Nucleico para COVID-19/economia , Teste de Ácido Nucleico para COVID-19/instrumentação , Sistemas CRISPR-Cas , Linhagem Celular , Proteínas do Nucleocapsídeo de Coronavírus/genética , Humanos , Nasofaringe/virologia , Imagem Óptica/instrumentação , Fosfoproteínas/genética , Testes Imediatos , Interferência de RNA , RNA Viral/genética , Sensibilidade e Especificidade , Carga Viral/economia , Carga Viral/instrumentação
4.
J Med Virol ; 93(6): 3707-3713, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33174623

RESUMO

As we strive towards the WHO goal of elimination of viral hepatitis as a public health threat by 2030, implementation of reliable, accurate diagnostic assays is crucial to identify those at risk of disease progression and those at risk of transmission. Ironically those at greatest risk of chronic hepatitis B are often in resource-poor regions with limited access to testing, collection, storage, and/or transportation of peripheral blood. The Xpert® HBV Viral Load assay provides an easy to use, convenient means of measuring load on GeneXpert platforms. In this study, the Xpert assay is evaluated against four commercially available high-throughput assays for Hepatitis B virus (HBV) loads. In addition application of dried blood spots (DBS) for estimation of viral load is assessed on real-world samples collected from a remote Pacific Island, Kiribati. A total of 107 serum/plasma samples were tested in the Xpert HBV load assay and compared with the Abbott m2000, Alinity m, and Roche Cobas CAP/CTM and 6800. Fifty-three DBS were tested in the Xpert assay and compared with matching serum samples. Overall 82% serum/plasma samples demonstrated good correlation between the Xpert and Roche and Abbott assays, to within 0.5 log10 IU/ml. The greatest discrepancies were seen at the limits of quantification of all assays. About 85.4% DBS gave estimable viral loads to within 1 log10 IU/ml of the serum load. The Xpert HBV viral load assay is recommended for all settings but particularly useful for resource-poor settings. Utility of DBS with the Xpert assay provides a simple means for testing in remote settings.


Assuntos
Teste em Amostras de Sangue Seco/normas , Vírus da Hepatite B/genética , Hepatite B/sangue , Técnicas de Diagnóstico Molecular/normas , Carga Viral/métodos , Carga Viral/normas , Teste em Amostras de Sangue Seco/métodos , Hepatite B/virologia , Humanos , Limite de Detecção , Técnicas de Diagnóstico Molecular/métodos , Mutação , Estudos Prospectivos , Kit de Reagentes para Diagnóstico/normas , Estudos Retrospectivos , Sensibilidade e Especificidade , Manejo de Espécimes , Carga Viral/instrumentação
5.
J Med Virol ; 93(6): 3999-4003, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32761911

RESUMO

BACKGROUND: Monitoring viral load (VL) is an essential part of the management of patients chronically infected with hepatitis B virus (HBV). The commercial HBV VL assays currently available are generally performed on high-throughput platforms for batch wise testing of plasma samples, with relatively long turn-around-times. Rapid VL testing could provide immediate input to clinical decision making. METHODS: One hundred two stored plasma samples from 102 patients who were previously tested for HBV VL by the Cobas Ampliprep/Taqman or Cobas 4800 (Roche, Pleasanton, CA), were analyzed by the recently introduced Cepheid Xpert HBV Viral Load Assay. Thirty-one of the 102 samples were negative for HBV DNA and 71 out of 102 samples had a detectable VL. HBV DNA loads ranged from <20 to 5E8 IU/mL. HBV genotypes (A, B, C, D, E, and G) were known for 52 of the VL positive samples. Correlation of VL results between both assays was determined by the Pearson correlation coefficient (r2 ). The level of concordance was assessed using the Bland-Altman analysis. RESULTS: HBV VLs correlated well between both assays, across all genotypes (Pearson correlation coefficient r2 = 0.987). Six samples exceeded a 0.5 log difference between assays. Bland-Altman analysis demonstrated a mean of the difference of -0.107 log and a standard deviation of 0.271 log. CONCLUSION: High correlation was observed between the Roche Cobas HBV Viral Load tests and the Xpert HBV Viral Load Assay, thus enabling rapid, random access, and accurate HBV VL assessment.


Assuntos
DNA Viral/sangue , Vírus da Hepatite B/genética , Hepatite B/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Carga Viral/instrumentação , Carga Viral/métodos , Genótipo , Hepatite B/sangue , Hepatite B/virologia , Vírus da Hepatite B/classificação , Vírus da Hepatite B/isolamento & purificação , Humanos , Limite de Detecção , Técnicas de Diagnóstico Molecular/normas , Sensibilidade e Especificidade
7.
J Clin Virol ; 125: 104289, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32097889

RESUMO

BACKGROUND: Early infant diagnosis (EID) of HIV-1 exposed infants enables timely initiation of antiretroviral therapy (ART), thereby allowing early diagnosis and treatment to slow disease progression and reduce mortality. Turn-around time to results, partially caused by low to medium throughput technology, remains a hindrance to early treatment. A major solution to this challenge is to incorporate high throughput and accurate technologies in the testing process. The Hologic Aptima Quant Dx Assay (Aptima) is a CE marked Real-Time TMA assay running on the high throughput Panther system. OBJECTIVES: The objective of this study was to evaluate the performance of Aptima for EID using dried blood spots. STUDY DESIGN: This was a cross-sectional prospective study of 2,048 infants seeking HIV services from health facilities in Western Kenya, Africa. Capillary Dried Blood Spot samples DBS were collected from infants with the consent of their mothers. The qualitative performance of Aptima was compared with the Roche COBAS Ampliprep/ COBAS Taqman HIV-1 Qualitative Test v2.0 (CAP/CTM), using these DBS. Demographic information of the participants was also collected. RESULTS: A total of 1,975 successful comparisons between the two platforms were included in the analysis. The overall agreement between the assays was 99.65 %. The sensitivity and specificity of Aptima was 95.24 % (95 % CI 88.40-98.19 %) and 99.84 % (95 % CI 99.49-99.92 %) respectively. CONCLUSIONS: Aptima assay has performance characteristics that are comparable to those of the Roche CAP/CTM for qualitative testing on DBS taken from infants. The two assays can therefore be used interchangeably for Early Infant Diagnosis of HIV.


Assuntos
Infecções por HIV/diagnóstico , HIV-1/isolamento & purificação , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Diagnóstico Molecular/normas , Kit de Reagentes para Diagnóstico/normas , Carga Viral/instrumentação , Estudos Transversais , Teste em Amostras de Sangue Seco/métodos , Diagnóstico Precoce , Feminino , Infecções por HIV/sangue , HIV-1/genética , Humanos , Lactente , Recém-Nascido , Quênia , Masculino , Técnicas de Diagnóstico Molecular/métodos , Estudos Prospectivos , RNA Viral/sangue , Sensibilidade e Especificidade , Carga Viral/métodos , Carga Viral/normas
8.
Arch Sex Behav ; 49(1): 195-209, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31630286

RESUMO

Stimulant use is associated with higher HIV viral load (VL) and sexual HIV transmission risk among men who have sex with men (MSM) living with HIV. There is little research on willingness of drug users living with HIV to fully participate in studies, especially those involving self-collection of biomarker data. This study presents findings from an at-home dried blood spot collection study measuring laboratory-quantified VL among U.S. HIV-positive MSM who reported high-risk sexual behavior and/or suboptimal antiretroviral therapy (ART) adherence to assess the association between drug-use behavior and (1) ability to complete a study protocol and (2) VL outcomes. Among recruited participants (n = 766), 35% reported stimulant drug use (amphetamines, cocaine, crack, crystal meth, ecstasy, or a combination of stimulant drugs), 39% reported using other drugs (heroin, marijuana, prescription opioids, and others), and 27% reported no drug use in the past 3 months. In all, 61% of enrolled participants completed the study protocol. Stimulant drug users were less likely (ARR 0.84; 95% CI 0.72-0.98) to complete the protocol than other drug users. Furthermore, other drug users were significantly less likely than non-drug users (ARR 0.52; 95% CI 0.28-0.97) to have an HIV VL result ≥ 1500 copies/mL. This study provides important estimates regarding the likelihood of participation in biomedical research activities among HIV-positive MSM with varying drug-use behaviors, showing that it is feasible to conduct such biomedical studies with drug-using MSM who report high-risk sexual behavior and struggle with their ART adherence.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Infecções por HIV/sangue , Homossexualidade Masculina/estatística & dados numéricos , Carga Viral/instrumentação , Adolescente , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Adulto Jovem
9.
J Clin Virol ; 122: 104212, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31765957

RESUMO

BACKGROUND: A new point-of-care (POC) HIV virus load technology has been recently developed and designed to be utilized in decentralized settings. Alere Technologies GmbH*, Germany, developed the mPIMA HIV-1/2 VL plasma test which uses real time PCR technology with 50 µl and a turnaround time of one hour. OBJECTIVE: Analyze the performance of mPIMA to detect and quantify HIV-1 and HIV-2 and compare with Abbott M2000 assay fooling patients HIV-1 failing ARV therapy. STUDY DESIGN: In this study we evaluate the mPIMA HIV-1/2 VL plasma test using 413 specimens from 270 patients failing ARV therapy, and compared its performance with Abbott RealTime HIV-1 Viral Load assay on the m2000 system. In addition, were determined VL in plasma specimens obtained from HIV-2 infected patients. RESULTS: The results strongly indicate that mPIMA HIV-1/2 VL plasma test can determine HIV-1 with concordance of 88.9 % (95 % CI 85.4-91.7) the reference test when 1000 HIV-1 VL threshold was used as WHO cutoff to identify therapy failure. The overall correlation between HIV-1 VL was 0928 (Pearson correlation coefficient of Linear regression) and the Bland-Altman showed a mean difference of -0.20 Log cp/mL between the two technology. mPIMA HIV-1/2 VL plasma test was also able to measure HIV-2 viral load in 16 specimens from Guinea-Bissau HIV-1/HIV-2 positive samples. CONCLUSIONS: These data support the use of mPIMA HIV-1/2 VL plasma test to follow up patients and select patients failing ART, guiding immediate clinical decisions such as adherence counseling or ART regimen switch during the patient consultation.


Assuntos
Infecções por HIV/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito/normas , RNA Viral/sangue , Carga Viral/instrumentação , Carga Viral/métodos , Fármacos Anti-HIV/uso terapêutico , Alemanha , Infecções por HIV/sangue , Infecções por HIV/tratamento farmacológico , HIV-1/isolamento & purificação , HIV-2/isolamento & purificação , Humanos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade
10.
PLoS One ; 14(8): e0221586, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31449559

RESUMO

INTRODUCTION: Viral load (VL) monitoring programs have been scaled up rapidly, but are now facing the challenge of providing access to the most remote facilities (the "last mile"). For the hardest-to-reach facilities in Zambia, we compared the cost of placing point of care (POC) viral load instruments at or near facilities to the cost of an expanded sample transportation network (STN) to deliver samples to centralized laboratories. METHODS: We extended a previously described geospatial model for Zambia that first optimized a STN for centralized laboratories for 90% of estimated viral load volumes. Amongst the remaining 10% of volumes, facilities were identified as candidates for POC placement, and then instrument placement was optimized such that access and instrument utilization is maximized. We evaluated the full cost per test under three scenarios: 1) POC placement at all facilities identified for POC; 2)an optimized combination of both on-site POC placement and placement at facilities acting as POC hubs; and 3) integration into the centralized STN to allow use of centralized laboratories. RESULTS: For the hardest-to-reach facilities, optimal POC placement covered a quarter of HIV-treating facilities. Scenario 2 resulted in a cost per test of $39.58, 6% less than the cost per test of scenario 1, $41.81. This is due to increased POC instrument utilization in scenario 2 where facilities can act as POC hubs. Scenario 3 was the most costly at $53.40 per test, due to high transport costs under the centralized model ($36 per test compared to $12 per test in scenario 2). CONCLUSIONS: POC VL testing may reduce the costs of expanding access to the hardest-to-reach populations, despite the cost of equipment and low patient volumes. An optimal combination of both on-site placement and the use of POC hubs can reduce the cost per test by 6-35% by reducing transport costs and increasing instrument utilization.


Assuntos
Geografia , Modelos Econômicos , Testes Imediatos/economia , Carga Viral/economia , Carga Viral/instrumentação , Custos e Análise de Custo , Humanos , Zâmbia
11.
Am J Clin Pathol ; 152(5): 558-562, 2019 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-31365738

RESUMO

OBJECTIVES: To compare quantified human immunodeficiency virus type 1 (HIV-1) viral load quantified using the cobas HIV-1 test with that obtained using the CAP/CTM HIV-1 and Abbott RealTime HIV-1 tests and evaluate the performance of cobas HIV-1 using the cobas 4800 system. METHODS: Clinical samples (n = 123) were quantitatively analyzed using the CAP/CTM HIV-1, Abbott RealTime HIV-1, and cobas HIV-1 tests, and the precision, linearity, and limit of detection of the cobas HIV-1 test were evaluated. RESULTS: Comparable results were obtained by both methods: ([log CAP/CTM HIV-1 value] = 0.979 * [log cobas HIV-1 test value] + 0.034) and ([log Abbott RealTime HIV-1 value] = 0.985 * [log cobas HIV-1 test value] + 0.027). cobas HIV-1 test results for 89.4% and 93.5% were within 0.5 log10 IU/mL of the CAP/CTM HIV-1 and Abbott RealTime HIV-1 results, respectively. CONCLUSIONS: The cobas HIV-1 test showed good performance, and its results correlated well with those of other two tests.


Assuntos
Infecções por HIV/virologia , HIV-1/genética , RNA Viral/sangue , Carga Viral/instrumentação , Carga Viral/métodos , Antirretrovirais/uso terapêutico , Infecções por HIV/sangue , Infecções por HIV/tratamento farmacológico , Humanos , Limite de Detecção , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade
12.
Anal Chem ; 91(14): 8751-8755, 2019 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-31117407

RESUMO

Serial dilution is a commonly used technique that generates a low-concentration working sample from a high-concentration stock solution and is used to set up screening conditions over a large dynamic range for biological study, optimization of reaction conditions, drug screening, etc. Creating an array of serial dilutions usually requires cumbersome manual pipetting steps or a robotic liquid handling system. Moreover, it is very challenging to set up an array of serial dilutions in nanoliter volumes in miniaturized assays. Here, a multistep SlipChip microfluidic device is presented for generating serial dilution nanoliter arrays in high throughput with a series of simple sliding motions. The dilution ratio can be precisely predetermined by the volumes of mother microwells and daughter microwells, and this paper demonstrates devices designed to have dilution ratios of 1:1, 1:2, and 1:4. Furthermore, an eight-step serial dilution SlipChip with a dilution ratio of 1:4 is applied for digital loop-mediated isothermal amplification (LAMP) across a large dynamic range and tested for hepatitis B viral load quantification with clinical samples. With 64 wells of each dilution and fewer than 600 wells in total, the serial dilution SlipChip can achieve a theoretical quantification dynamic range of 7 orders of magnitude.


Assuntos
Vírus da Hepatite B/isolamento & purificação , Hepatite B/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Carga Viral/instrumentação , Hepatite B/sangue , Humanos , Dispositivos Lab-On-A-Chip
13.
J Clin Microbiol ; 57(4)2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30728197

RESUMO

Plasma HIV viral load testing is the preferred means of monitoring antiretroviral treatment response. Dried blood spots (DBSs) hold considerable logistical advantages over EDTA samples, but they more frequently misclassify virological failure and have higher limits of detection (LoD). Plasma separation cards (PSCs) may overcome these limitations. Health workers collected EDTA whole blood by venipuncture and 140 µl of finger-prick blood by capillary tube from 53 HIV-infected adults. Capillary blood was immediately transferred to PSCs. Additionally, 432 EDTA samples from HIV-infected adults were spotted onto PSCs and analyzed together with the finger-prick samples. Specificity and sensitivity of PSC with paired EDTA-PSC samples tested on a cobas 6800/8800 system with the cobas HIV-1 test (cobas HIV) was determined. LoD (3rd HIV-1 WHO International Standard) and stability at a range of temperatures and storage durations was determined using cobas HIV and cobas AmpliPrep/cobas TaqMan HIV-1 test v2.0 (CAP/CTM). Of 132 specimens with quantitative values for paired EDTA-PSC samples, the mean log10 difference between samples was 0.05 copies/ml (95% confidence interval [CI], -0.01 to 0.11). The LoD for cobas HIV was 790.2 copies/ml and for CAP/CTM was 737.9 copies/ml. At 1,000 copies/ml, PSC sensitivity was 97.0% (128/132) and specificity was 97.2% (343/353). Results correlated well with those from EDTA samples (Deming R2 = 0.90). PSC results were unaffected by temperature and storage conditions. PSC samples correlate well with plasma viral load and have adequate sensitivity and specificity. The improved performance may be as a result of a reduction in contribution from cell-associated viral nucleic acids. The card provides an alternative sample collection technology to DBSs.


Assuntos
Teste em Amostras de Sangue Seco/normas , HIV-1/isolamento & purificação , Plasma/virologia , RNA Viral/sangue , Manejo de Espécimes/instrumentação , Carga Viral/métodos , Adulto , Coleta de Amostras Sanguíneas , Filtração/instrumentação , Filtração/métodos , Infecções por HIV/sangue , Infecções por HIV/diagnóstico , Humanos , Limite de Detecção , Papel , RNA Viral/isolamento & purificação , Sensibilidade e Especificidade , Manejo de Espécimes/métodos , Temperatura , Carga Viral/instrumentação
15.
Hum Gene Ther Methods ; 29(2): 96-103, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29378428

RESUMO

Lentivirus is one of the best vehicles in delivering exogenous genes for therapeutics. Prior to application, it is very important to determine the infectious titer, which measures only mature virus capable of infecting target cells. Quantitative polymerase chain reaction (PCR) and fluorescence-activated cell sorting are commonly used for determination of infectious titer. This study introduces a new method based on Droplet Digital PCR (ddPCR), a recently developed PCR technology that quantifies the absolute amount of target DNA in the reaction. In this study, the dynamic range, Limit of Quantification (LOQ), and data acceptance criteria for ddPCR are defined against lentiviral sequence. ddPCR performance is also compared to established FACS and qPCR methods. This work not only demonstrates the feasibility of ddPCR in determining lentiviral infectious titer, but provides a detailed method that can be easily adapted by the scientific community.


Assuntos
Vetores Genéticos/metabolismo , HIV-1/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Transdução Genética/métodos , Carga Viral/métodos , Variações do Número de Cópias de DNA , Citometria de Fluxo , Vetores Genéticos/química , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo , Células HEK293 , HIV-1/metabolismo , Humanos , Limite de Detecção , Plasmídeos/química , Plasmídeos/metabolismo , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , Reação em Cadeia da Polimerase em Tempo Real/normas , Reprodutibilidade dos Testes , Telomerase/genética , Telomerase/metabolismo , Transgenes , Carga Viral/instrumentação , Carga Viral/normas
16.
Sci Rep ; 7(1): 13658, 2017 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-29057945

RESUMO

There is a global need for HIV viral load point-of-care (PoC) assays to monitor patients receiving antiretroviral therapy. UNICORN was the first study of an off-label protocol using whole blood finger-prick samples tested with and without a simple three minute spin using a clinic-room microcentrifuge. Two PoC assays were evaluated in 40 HIV-positive participants, 20 with detectable and 20 with undetectable plasma viral load (pVL) (<20 copies/ml). Using 100 µl finger-prick blood samples, the Cepheid Xpert HIV-1 Viral Load and HIV-1 Qual cartridges were compared with laboratory pVL assessment (TaqMan, Roche). For participants with undetectable viraemia by TaqMan, there was poor concordance without centrifugation with the TaqMan platform with only 40% 'undetectable' using Xpert VL and 25% 'not detected' using the Qual assay. After a 3 minute spin, 100% of samples were undetectable using either assay, showing full concordance with the TaqMan assay. Defining a lower limit of detection of 1000 copies/ml when including a spin, there was 100% concordance with the TaqMan platform with strong correlation (rho 0.95 and 0.94; p < 0.0001 for both assays). When including a simple microcentrifugation step, finger-prick PoC testing was a quick and accurate approach for assessing HIV viraemia, with excellent concordance with validated laboratory approaches.


Assuntos
Coleta de Amostras Sanguíneas , Infecções por HIV/sangue , Infecções por HIV/virologia , HIV-1 , Testes Imediatos , Carga Viral , Adolescente , Adulto , Idoso , Coleta de Amostras Sanguíneas/métodos , Centrifugação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Carga Viral/instrumentação , Carga Viral/métodos , Adulto Jovem
17.
J Clin Virol ; 97: 18-21, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29080433

RESUMO

BACKGROUND: HCV RNA screening of large sample repositories provides data on HCV epidemic patterns that may help guide control policies. In resource-limited settings, shipment of frozen samples to molecular laboratory facilities and testing of individual samples may be prohibitively expensive. OBJECTIVE: Our aim was to detect and sequence HCV RNA in a large HIV-positive cohort from Kumasi, Ghana, using pooled and individual dried plasma spots (DPS) produced from samples stored at -80°C. STUDY DESIGN: In the validation phase, replicate DPS were prepared with six dilutions (500-10,000 IU/ml) of the 4th International Standard for HCV and tested in three independent experiments. In the testing phase, DPS prepared with plasma samples from 875 HIV-positive subjects were pooled for screening, followed by testing of individual DPS of positive pools. Input from individual DPS was two 6mm punches; pools comprised two punches from each of five DPS. Genotypes were determined by Sanger sequencing of HCV core and NS5B. RESULTS: With the dilution series, sensitivity of HCV RNA detection was ≥2500 IU/ml. Replicate DPS gave intra-assay and inter-assay coefficients of variation ≤1.4%. With the stored samples, HCV RNA was detected in 5/175 DPS pools and in one DPS from each positive pool, yielding a HCV RNA prevalence of 5/875 (0.57%; 95% confidence interval 0.07-1.07%). The five samples were sequenced as HCV genotypes 2l and 2r. DISCUSSION: DPS allowed reproducible HCV RNA detection, and pooling effectively contained the cost and labour of screening a previously untested, low-prevalence cohort. DPS were also suitable for HCV sequencing.


Assuntos
Hepacivirus/genética , Hepatite C/diagnóstico , Plasma/virologia , RNA Viral/isolamento & purificação , Carga Viral/métodos , Genótipo , Gana/epidemiologia , Infecções por HIV/complicações , Infecções por HIV/epidemiologia , Infecções por HIV/virologia , Hepatite C/epidemiologia , Hepatite C/virologia , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Programas de Rastreamento/métodos , RNA Viral/genética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Manejo de Espécimes , Carga Viral/instrumentação
18.
PLoS One ; 12(6): e0179316, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28622370

RESUMO

BACKGROUND: Routine HIV viral load testing is not widely accessible in most resource-limited settings, including Kenya. To increase access to viral load testing, alternative sample types like dried blood spots (DBS), which overcome the logistic barriers associated with plasma separation and cold chain shipment need to be considered and evaluated. The current study evaluated matched dried blood spots (DBS) and dried plasma spots (DPS) against plasma using the Abbott M 2000 (Abbott) and Roche Cobas Ampliprep/Cobas TaqMan (CAP/CTM) quantitative viral load assays in western Kenya. METHODS: Matched plasma DBS and DPS were obtained from 200 HIV-1 infected antiretroviral treatment (ART)-experienced patients attending patient support centers in Western Kenya. Standard quantitative assay performance parameters with accompanying 95% confidence intervals (CI) were assessed at the assays lower detection limit (400cps/ml for CAP/CTM and 550cps/ml for Abbott) using SAS version 9.2. Receiver operating curves (ROC) were further used to assess viral-load thresholds with best assay performance (reference assay CAP/CTM plasma). RESULTS: Using the Abbott test, the sensitivity and specificity, respectively, for DPS were (97.3%, [95%CI: 93.2-99.2] and 98.1% [95%CI: 89.7-100]) and those for DBS (93.9% [95%CI: 88.8-97.2] and 88.0% [95%CI: 82.2-92.4]). The correlation and agreement using paired plasma and DPS/DBS were strong, with r2 = 90.5 and rc = 68.1. The Bland-Altman relative percent change was 95.3 for DPS, (95%CI: 90.4-97.7) and 73.6 (95%CI: 51.6-86.5) for DBS. Using the CAP/CTM assay, the sensitivity for DBS was significantly higher compared to DPS (100.0% [95% CI: 97.6-100.0] vs. 94.7% [95%CI: 89.8-97.7]), while the specificity for DBS was lower: 4%, [95% CI: 0.4-13.7] compared to DPS: 94.0%, [95% CI: 83.5-98.7]. When compared under different clinical relevant thresholds, the accuracy for the Abbott assay was 95% at the 1000cps/ml cut-off with a sensitivity and specificity of 96.6% [95% CI 91.8-98.7] and 90.4% [95% CI 78.2-96.4] respectively. The optimum threshold was at 3000 cps/ml with an accuracy of 95.5%, sensitivity and specificity of 94.6% [95%CI 89.3-97.5] and 98.1% [95%CI 88.4-99.9]) respectively. The best threshold for CAP/CTM was at 4000 copies /mL, with 92.5% accuracy (sensitivity of 96.0% [95%CI 91.0-98.3] and specificity of 82.7% [95%CI 69.2-91.3]). CONCLUSIONS: There was similar performance between matched DBS, DPS and plasma using the Abbott test, and good correlation for matched DPS and plasma using the CAPCTM test. The findings suggest that DBS and DPS may be reliably used as alternative specimens to plasma to measure HIV-1 VL using Abbott, and DPS may be reliably used with CAP/CTM in resource-limited settings.


Assuntos
Teste em Amostras de Sangue Seco , Infecções por HIV/sangue , Infecções por HIV/genética , HIV-1 , Reação em Cadeia da Polimerase , Carga Viral , Teste em Amostras de Sangue Seco/instrumentação , Teste em Amostras de Sangue Seco/métodos , Feminino , Infecções por HIV/epidemiologia , HIV-1/genética , HIV-1/metabolismo , Humanos , Quênia/epidemiologia , Masculino , Reação em Cadeia da Polimerase/instrumentação , Reação em Cadeia da Polimerase/métodos , Sensibilidade e Especificidade , Carga Viral/instrumentação , Carga Viral/métodos
19.
J Clin Virol ; 92: 75-82, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28599228

RESUMO

BACKGROUND: Viral load monitoring is essential for patients under treatment for HIV. Beckman Coulter has developed the VERIS HIV-1 Assay for use on the novel, automated DxN VERIS Molecular Diagnostics System.¥ OBJECTIVES: Evaluation of the clinical performance of the new quantitative VERIS HIV-1 Assay at multiple EU laboratories. STUDY DESIGN: Method comparison with the VERIS HIV-1 Assay was performed with 415 specimens at 5 sites tested with COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 Test, v2.0, 169 specimens at 3 sites tested with RealTime HIV-1 Assay, and 202 specimens from 2 sites tested with VERSANT HIV-1 Assay. Patient monitoring sample results from 4 sites were also compared. RESULTS: Bland-Altman analysis showed the average bias between VERIS HIV-1 Assay and COBAS HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay to be 0.28, 0.39, and 0.61 log10 cp/mL, respectively. Bias at low end levels below 1000cp/mL showed predicted bias to be <0.3 log10 cp/mL for VERIS HIV-1 Assay versus COBAS HIV-1 Test and RealTime HIV-1 Assay, and <0.5 log10cp/mL versus VERSANT HIV-1 Assay. Analysis on 174 specimens tested with the 0.175mL volume VERIS HIV-1 Assay and COBAS HIV-1 Test showed average bias of 0.39 log10cp/mL. Patient monitoring results using VERIS HIV-1 Assay demonstrated similar viral load trends over time to all comparators. CONCLUSIONS: The VERIS HIV-1 Assay for use on the DxN VERIS System demonstrated comparable clinical performance to COBAS® HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay.


Assuntos
Infecções por HIV/diagnóstico , HIV-1/fisiologia , Técnicas de Diagnóstico Molecular , RNA Viral/sangue , Carga Viral/métodos , Europa (Continente) , Infecções por HIV/virologia , HIV-1/genética , Humanos , Colaboração Intersetorial , Programas de Rastreamento , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade , Carga Viral/instrumentação
20.
Biochem Biophys Res Commun ; 492(4): 558-564, 2017 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-28501619

RESUMO

Flaviviruses are widespread and cause clinically relevant arboviral diseases that impact locally and as imported travel-related infections. Direct detection of viraemia is limited, being typically undetectable at onset of symptoms. Therefore, diagnosis is primarily based on serology, which is complicated by high cross-reactivity across different species. The overlapping geographical distribution of the vectors in areas with a weak healthcare system, the increase of international travel and the similarity of symptoms highlight the need for rapid and reliable multi-parametric diagnostic tests in point-of-care formats. To this end we developed a bi-parametric serological microarray using recombinant NS1 proteins from Tick-borne encephalitis virus and West Nile virus coupled to a low-cost, label-free detection device based on the Reflective Phantom Interface (RPI) principle. Specific sequential detection of antibodies in solution demonstrates the feasibility of the approach for the surveillance and diagnosis of Flaviviruses.


Assuntos
Anticorpos Antivirais/imunologia , Flavivirus/isolamento & purificação , Imunoensaio/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Refratometria/instrumentação , Carga Viral/instrumentação , Anticorpos Antivirais/sangue , Antígenos Virais/genética , Antígenos Virais/imunologia , Desenho de Equipamento , Análise de Falha de Equipamento , Flavivirus/imunologia , Humanos , Imunoensaio/métodos , Refratometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coloração e Rotulagem , Carga Viral/imunologia , Carga Viral/métodos