Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.247
Filtrar
1.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742501

RESUMO

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Assuntos
Lentes de Contato , Ceratocone , Esclera , Acuidade Visual , Humanos , Ceratocone/cirurgia , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Ceratocone/terapia , Feminino , Masculino , Adulto , Esclera/cirurgia , Implantação de Prótese/métodos , Implantação de Prótese/instrumentação , Resultado do Tratamento , Topografia da Córnea , Próteses e Implantes , Adulto Jovem , Ajuste de Prótese/métodos , Adolescente , Substância Própria/cirurgia
2.
BMC Ophthalmol ; 24(1): 201, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38698363

RESUMO

BACKGROUND: We aimed to employ Optical Coherence Tomography Angiography (OCTA) to comprehensively assess changes in the optic nerve head (ONH) and macular perfusion before and after the Corneal Collagen Cross-Linking (CCL) procedure in patients with keratoconus. METHODS: A total of 22 keratoconus patient's candidate for CCL procedures were included based on specific criteria, with meticulous exclusion criteria in place to minimize potential confounders. Participants underwent OCTA assessments of the ONH and macula using the Spectralis OCT (Heidelberg) before CCL, as well as at 1- and 3-months post-CCL. MATLAB software was utilized for image analysis. RESULTS: The mean age of the participants was 20.09 ± 6.11, including 59% male, and the mean intraocular pressure (IOP) before the surgery was 13.59 ± 2.85 mmHg. Peripapillary Retinal nerve fiber layer (ppRNFL) thickness and overall retinal thickness remained stable post-CCL. However, significant alterations were observed in macular vessel density, emphasizing regional variations in vascular response. For macular large vessel density (LVD), both superficial and deep vascular complex (SVC and DVC) demonstrated significant differences between before surgery and the 3 months post-surgery follow-up (p < 0.001 and p = 0.002, respectively). Optic nerve head markers demonstrated relative stability, except for changes in avascular complex density, which was 49.2 ± 2.2% before the surgery and decrease to 47.6 ± 1.7% three months after the operation (P-value = 0.005). CONCLUSION: While CCL appears to maintain the integrity of certain ocular structures, alterations in macular perfusion post-CCL suggest potential effects on retinal blood supply. Long-term monitoring is crucial to understand the implications of these changes, particularly in the context of conditions such as diabetes.


Assuntos
Colágeno , Reagentes de Ligações Cruzadas , Angiofluoresceinografia , Ceratocone , Disco Óptico , Vasos Retinianos , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Ceratocone/fisiopatologia , Ceratocone/diagnóstico , Masculino , Feminino , Colágeno/metabolismo , Adulto Jovem , Adulto , Angiofluoresceinografia/métodos , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/fisiopatologia , Disco Óptico/irrigação sanguínea , Adolescente , Estudos Prospectivos , Fármacos Fotossensibilizantes/uso terapêutico , Fotoquimioterapia/métodos , Macula Lutea/diagnóstico por imagem , Macula Lutea/irrigação sanguínea
3.
Jpn J Ophthalmol ; 68(3): 225-232, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38557918

RESUMO

PURPOSE: We aimed to compare the efficacy and safety of accelerated contact lens-assisted cross-linking (CA-CXL) with Lotrafilcon B and Comfilcon A lenses in keratoconus (KC) patients with thin corneas. STUDY DESIGN: Retrospective, single-center study. MATERIALS AND METHODS: We retrospectively included 51 eyes of 39 KC patients with corneal thickness <400µm after epithelial scraping (Epi-off), who underwent accelerated CA-CXL treatment with Lotrafilcon B (n=20) and Comfilcon A (n=31). Uncorrected and corrected distance visual acuity (UDVA and CDVA), manifest refraction values, corneal topographic data and endothelial cell density were recorded at preoperative and postoperative 1st, 3rd and 6th month controls. RESULTS: CDVA in the Comfilcon A group was higher than CDVA before surgery at 6 months postoperatively (p<0.001). When the two lenses were compared, CDVA was found to be significantly higher in the Lotrafilcon B group in the preoperative, postoperative 1st month and 3rd month values, but there was no significant difference between the postoperative 6th month values (p=0.028, p=0.018, p=0.044, p=0.181, respectively). The maximum keratometry (Kmax) value at the 6th month after surgery in the Comfilcon A group was significantly lower than in the Lotrafilcon B group (p=0,009). There was no significant difference between the endothelial cell density values between the groups (p=0.623, p=0.609, p=0.794, p=0.458, respectively). There was no significant difference between the progression, regression, and stability rates of the two groups (p=0.714). CONCLUSIONS: Accelerated CA-CXL with Lotrafilcon B and Comfilcon A silicone hydrogel lenses is a safe and effective method to stop progression in patients with thin corneas.


Assuntos
Colágeno , Topografia da Córnea , Reagentes de Ligações Cruzadas , Ceratocone , Fotoquimioterapia , Fármacos Fotossensibilizantes , Refração Ocular , Riboflavina , Acuidade Visual , Humanos , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Ceratocone/tratamento farmacológico , Ceratocone/terapia , Ceratocone/metabolismo , Feminino , Masculino , Estudos Retrospectivos , Acuidade Visual/fisiologia , Fármacos Fotossensibilizantes/uso terapêutico , Adulto , Riboflavina/uso terapêutico , Fotoquimioterapia/métodos , Adulto Jovem , Refração Ocular/fisiologia , Colágeno/metabolismo , Resultado do Tratamento , Córnea/patologia , Raios Ultravioleta , Seguimentos , Adolescente , Contagem de Células , Substância Própria/metabolismo , Endotélio Corneano/patologia , Lentes de Contato Hidrofílicas , Crosslinking Corneano
4.
Indian J Ophthalmol ; 72(Suppl 3): S495-S500, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38648457

RESUMO

PURPOSE: This retrospective longitudinal study evaluated the biomechanical E-staging in KC corneas before and after intracorneal ring segment (ICRS) implantation (Intacs® SK, Addition Technology, Illinois, United States). METHODS: Biomechanical E-staging for ectatic corneal diseases was applied retrospectively on 49 KC corneas of 41 patients who underwent ICRS implantation. The main outcome parameters included the Corvis Biomechanical Factor (CBiF, the linearized Corvis Biomechanical Index and the biomechanical parameters included), the resulting biomechanical E-staging, the stress-strain index, thinnest corneal thickness (TCT), maximal anterior keratometry (Kmax), and the anterior radius of curvature (ARC). They were evaluated at 1.9 ± 1.1 months preoperatively and postoperatively after 2.8 ± 0.7, 5.8 ± 1.0, and 10.6 ± 2.3 months. RESULTS: The CBiF decreased (4.9 ± 0.5 | 4.7 ± 0.5, P = 0.0013), and the E-staging increased significantly (2.8 ± 0.8 | 3.1 ± 0.9, P = 0.0012, paired t-test) from preoperatively to the first postoperative follow-up. The difference remained significant after 6 months; however, there was no more difference after 11 months. TCT was stable, whereas Kmax and ARC significantly decreased after ICRS implantation (TCT: 464 ± 49, 470 ± 51, 467 ± 38, 461 ± 48; Kmax: 56.3 ± 4.5, 54.7 ± 4.5, 54.2 ± 4.8, 54.1 ± 4.3; ARC: 51.5 ± 3.4, 48.3 ± 3.8, 48.6 ± 3.0, 48.6 ± 3.2 preoperatively and 3, 6, and 11 months postoperatively, respectively). Besides Kmax and ARC, Ambrósio's relational thickness to the horizontal profile (ARTh) was the only parameter that was significantly lower than preoperatively at any follow-up (P ≤ 0.0024, Wilcoxon matched-pairs test). CONCLUSION: Intacs® SK implantation results in an increasing biomechanical E-staging in the first postoperative months with stabilization near preoperative values after 1 year. Significantly lower ARTh values at any follow-up document the ICRS effect and contribute to a slightly higher postoperative biomechanical E-staging value.


Assuntos
Córnea , Substância Própria , Topografia da Córnea , Ceratocone , Próteses e Implantes , Implantação de Prótese , Acuidade Visual , Humanos , Ceratocone/cirurgia , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Estudos Retrospectivos , Feminino , Masculino , Adulto , Implantação de Prótese/métodos , Córnea/patologia , Seguimentos , Substância Própria/patologia , Substância Própria/cirurgia , Acuidade Visual/fisiologia , Fenômenos Biomecânicos , Adulto Jovem , Pessoa de Meia-Idade , Refração Ocular/fisiologia , Desenho de Prótese , Adolescente
5.
Indian J Ophthalmol ; 72(5): 712-717, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38648433

RESUMO

PURPOSE: To compare the changes encountered in corneal biomechanics and aberration profile following accelerated corneal collagen cross-linking (CXL) using hypo-osmolar and iso-osmolar riboflavin in corneal thicknesses of <400 and >400 microns, respectively. METHODS: This is a prospective, interventional, comparative study involving 100 eyes of 75 patients with progressive keratoconus. Eyes were divided into two groups based on corneal thickness: group 1 included eyes with a corneal thickness of <400 microns who underwent hypo-osmolar CXL, and group 2 included eyes with a corneal thickness of >400 microns who underwent iso-osmolar CXL. Corneal biomechanical and aberration profiles were evaluated and compared between groups. RESULTS: In group 1, all higher-order aberrations (HOA) except secondary astigmatism significantly decreased from baseline; however, in group 2, only coma and trefoil decreased. The corneal resistance factor and corneal hysteresis significantly improved in both groups, which was significantly greater in group 2 than in group 1. The change in inverse radius, deformation amplitude, and tomographic biomechanical index was significantly improved in group 2 as compared to group 1. CONCLUSION: Improvement in corrected distance visual acuity and decrease in HOA were significantly better in the hypo-osmolar CXL group; however, the improvement in biomechanical strength of the cornea was significantly better in the iso-osmolar group.


Assuntos
Colágeno , Córnea , Topografia da Córnea , Reagentes de Ligações Cruzadas , Ceratocone , Fármacos Fotossensibilizantes , Riboflavina , Raios Ultravioleta , Acuidade Visual , Adolescente , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Fenômenos Biomecânicos , Colágeno/metabolismo , Córnea/diagnóstico por imagem , Córnea/fisiopatologia , Córnea/efeitos dos fármacos , Substância Própria/metabolismo , Substância Própria/efeitos dos fármacos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Reagentes de Ligações Cruzadas/uso terapêutico , Seguimentos , Ceratocone/tratamento farmacológico , Ceratocone/fisiopatologia , Ceratocone/diagnóstico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Prospectivos , Refração Ocular/fisiologia , Riboflavina/uso terapêutico , Acuidade Visual/fisiologia , Criança
6.
Arq Bras Oftalmol ; 87(4): e2023, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38656029

RESUMO

PURPOSE: To assess the outcomes of deep anterior lamellar keratoplasty or penetrating keratoplasty at the scar and the edema stages. METHODS: Forty-five patients (45 eyes) with keratoconus scar stage (scar group, n=26; penetrating keratoplasty a subgroup, n=7; deep anterior lamellar keratoplasty b subgroup, n=19) and keratoconus edema stage (edema group, n=19; penetrating keratoplasty c subgroup, n=12; deep anterior lamellar keratoplasty d group, n=7) who received penetrating keratoplasty or deep anterior lamellar keratoplasty from 2000 to 2022 were retrospectively studied. At 1, 6, and 12 months after surgery, the best-corrected visual acuity, astigmatism, spherical equivalent, corneal endothelial cell density, and complications were analyzed. RESULTS: The best-corrected visual acuity and average corneal endothelial cell loss rate were not significantly different between the scar and edema groups (p>0.05). At 6 and 12 months after surgery, the astigmatism and spherical equivalent in the scar group were significantly lower than those in the edema group (p<0.05). The spherical equivalent of the deep anterior lamellar keratoplasty b subgroup was lower than that of the penetrating keratoplasty a subgroup in the scar group 6 months after surgery (p<0.05). In the edema group, there was no significant difference in spherical equivalent between subgroups (p>0.05). There were no significant differences in best-corrected visual acuity and astigmatism between subgroups within the two groups (p>0.05). In comparison to the scar group, the edema group experienced more complications. According to a survival analysis, there was no statistically significant difference between the scar group and the edema group regarding the progression of vision. CONCLUSIONS: In terms of the outcomes and prognosis for vision after keratoplasty with edema stage and scar stage, deep anterior lamellar keratoplasty may be as effective as penetrating keratoplasty.


Assuntos
Cicatriz , Edema da Córnea , Ceratocone , Ceratoplastia Penetrante , Acuidade Visual , Humanos , Ceratocone/cirurgia , Ceratocone/complicações , Ceratocone/fisiopatologia , Masculino , Feminino , Estudos Retrospectivos , Ceratoplastia Penetrante/métodos , Adulto , Cicatriz/etiologia , Resultado do Tratamento , Edema da Córnea/cirurgia , Edema da Córnea/etiologia , Adulto Jovem , Transplante de Córnea/métodos , Fatores de Tempo , Adolescente , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Contagem de Células , Endotélio Corneano/patologia , Endotélio Corneano/cirurgia
7.
Cont Lens Anterior Eye ; 47(3): 102132, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38462405

RESUMO

PURPOSE: To determine central and peripheral corneal sagittal height (z) values in keratoconus and healthy eyes with the Oculus Pentacam point-by-point data extraction software. METHODS: Forty eyes from patients with central or paracentral (4 mm) keratoconus (32.0 ± 12.5 years) and 40 eyes from healthy subjects (29.1 ± 7.9 years) were included. The Oculus Pentacam software was employed to determine z values referenced to a plane tangent to the corneal apex for five circles concentric with the centre of the pupil with diameters 4, 6, 8, 9 and 10.5 mm. The variability in z values within each circle and in terms of corneal meridians and quadrants was explored in keratoconus and healthy eyes. RESULTS: Keratoconus apex was mainly located at the inferior-temporal quadrant, at a distance from 0.083 mm to 3.59 mm with reference to the centre of the pupil. Mean z was larger in keratoconus than in healthy eyes in all explored corneal diameters (all p < 0.001). Variation in z values was larger in keratoconus than healthy eyes only at the central areas of the cornea (4 mm, p = 0.02; 6 mm, p = 0.011), but not in the periphery (8, 9 and 10.5 mm). In keratoconus, the frequency of minimum z values in the IT quadrant was greater than in healthy eyes. CONCLUSION: Although peripheral z values were larger in keratoconus, rotational variations were comparable between keratoconus and healthy eyes, suggesting that large diameter spherical rigid corneal contact lenses may be an alternative to scleral lenses in central and paracentral keratoconus.


Assuntos
Córnea , Topografia da Córnea , Ceratocone , Humanos , Ceratocone/fisiopatologia , Ceratocone/diagnóstico , Adulto , Feminino , Masculino , Córnea/patologia , Adulto Jovem , Pessoa de Meia-Idade , Voluntários Saudáveis , Adolescente
8.
Cont Lens Anterior Eye ; 47(3): 102145, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38472013

RESUMO

PURPOSE: To report a case of ulcerative keratopathy following implantation of acellular porcine corneal stroma (APCS) in a patient with keratoconus (KC). METHODS: A 58 year-old patient initially presented with an ulcerative keratopathy in the left eye. Previously, several corneal procedures (including radial keratotomy, laser-in-situ keratomileusis, crosslinking) were performed for KC. Eight months ago, an APCS lenticule (Xenia corneal implant, Gebauer Medizintechnik GmbH, Neuhausen, Germany) was implanted into a stromal pocket because of progressive keratectasia. Visual acuity was hand movement. Anterior segment optical coherence tomography showed a space between the APCS lenticule and the host stroma. Excimer laser-assisted penetrating keratoplasty (PKP, 8.0/8.1 mm) was performed in the left eye. The corneal explant was investigated by light and transmission electron microscopy. RESULTS: Best-corrected visual acuity was 20/40 six weeks after PKP. Light microscopy demonstrated a stromal ulceration down to the APCS lenticule. No stromal cells could be found within the APCS lenticule eight months after implantation. The APCS lenticule did not show a green stain of the collagens with Masson-Goldner staining and exhibited a strong Periodic acid-Schiff positive reaction. Electron microscopy of the APCS lenticule revealed cross-linked collagen lamellae without cellular components. Close to the interface, corneal collagen lamellae of the host cornea were disorganized. Few vital keratocytes were present on the surface of the lenticule and appeared to cause mechanical disruption of the host stroma along the lenticule-stroma interface. CONCLUSION: APCS implantation may lead to severe complications such as ulcerative keratopathy in otherwise uncomplicated KC corneas. In such cases, excimer laser-assisted PKP or Deep Anterior Lamellar Keratoplasty are the methods of choice to restore visual acuity.


Assuntos
Substância Própria , Úlcera da Córnea , Ceratocone , Acuidade Visual , Ceratocone/cirurgia , Ceratocone/fisiopatologia , Humanos , Substância Própria/cirurgia , Substância Própria/patologia , Pessoa de Meia-Idade , Animais , Suínos , Acuidade Visual/fisiologia , Úlcera da Córnea/cirurgia , Úlcera da Córnea/etiologia , Úlcera da Córnea/diagnóstico , Masculino , Tomografia de Coerência Óptica , Ceratoplastia Penetrante , Topografia da Córnea
9.
Ophthalmic Physiol Opt ; 44(4): 746-756, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38389207

RESUMO

PURPOSE: The goal was to use SyntEyes modelling to estimate the allowable alignment error of wavefront-guided rigid contact lens corrections for a range of normal and keratoconic eye aberration structures to keep objectively measured visual image quality at or above average levels of well-corrected normal eyes. Secondary purposes included determining the required radial order of correction, whether increased radial order of the corrections further constrained the allowable alignment error and how alignment constraints vary with keratoconus severity. METHODS: Building on previous work, 20 normal SyntEyes and 20 keratoconic SyntEyes were fitted with optimised wavefront-guided rigid contact lens corrections targeting between three and eight radial orders that drove visual image quality, as measured objectively by the visual Strehl ratio, to near 1 (best possible) over a 5-mm pupil for the aligned position. The resulting wavefront-guided contact lens was then allowed to translate up to ±1 mm in the x- and y-directions and rotate up ±15°. RESULTS: Allowable alignment error changed as a function of the magnitude of aberration structure to be corrected, which depends on keratoconus severity. This alignment error varied only slightly with the radial order of correction above the fourth radial order. To return the keratoconic SyntEyes to average levels of visual image quality depended on maximum anterior corneal curvature (Kmax). Acceptable tolerances for misalignment that returned keratoconic visual image quality to average normal levels varied between 0.29 and 0.63 mm for translation and approximately ±6.5° for rotation, depending on the magnitude of the aberration structure being corrected. CONCLUSIONS: Allowable alignment errors vary as a function of the aberration structure being corrected, the desired goal for visual image quality and as a function of keratoconus severity.


Assuntos
Lentes de Contato , Topografia da Córnea , Ceratocone , Acuidade Visual , Humanos , Ceratocone/fisiopatologia , Ceratocone/diagnóstico , Topografia da Córnea/métodos , Adulto , Feminino , Masculino , Acuidade Visual/fisiologia , Adulto Jovem , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/diagnóstico , Refração Ocular/fisiologia , Córnea/diagnóstico por imagem , Córnea/fisiopatologia
10.
J Cataract Refract Surg ; 50(5): 523-533, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38288954

RESUMO

Corneal crosslinking (CXL) is used for treating keratoconus and post-laser in situ keratomileusis ectasia. However, refractive surgery is not usually performed with prophylactic CXL. Therefore, we performed a meta-analysis comparing outcomes of refractive surgeries with vs without prophylactic CXL. We systematically searched databases for studies comparing refractive surgeries for myopic correction with vs without prophylactic corneal crosslinking. Review Manager 5.4.1 was used to perform statistical analysis. We included 2820 eyes from 28 studies. Compared with refractive surgery alone, surgery with prophylactic CXL resulted in decreased central corneal thickness, corrected distance visual acuity logMAR, and safety and efficacy indices. There were no significant differences in postoperative uncorrected distance visual acuity of 20/20 or better at ≥12 months and other visual outcomes among both groups. More randomized controlled trials with standard crosslinking protocols are needed to analyze the prophylactic use of crosslinking with refractive surgeries.


Assuntos
Colágeno , Reagentes de Ligações Cruzadas , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ceratectomia Fotorrefrativa , Fármacos Fotossensibilizantes , Riboflavina , Acuidade Visual , Humanos , Reagentes de Ligações Cruzadas/uso terapêutico , Fármacos Fotossensibilizantes/uso terapêutico , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Riboflavina/uso terapêutico , Colágeno/metabolismo , Acuidade Visual/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Ceratectomia Fotorrefrativa/métodos , Fotoquimioterapia/métodos , Lasers de Excimer/uso terapêutico , Substância Própria/metabolismo , Substância Própria/cirurgia , Raios Ultravioleta , Ceratocone/fisiopatologia , Ceratocone/metabolismo , Ceratocone/cirurgia , Ceratocone/tratamento farmacológico , Cirurgia da Córnea a Laser/métodos , Refração Ocular/fisiologia
11.
Graefes Arch Clin Exp Ophthalmol ; 262(6): 1839-1845, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38217766

RESUMO

PURPOSE: To assess the accuracy of intraocular lens (IOL) power formulas, namely, SRK/T, Haigis, Barrett Universal II, Barrett True-K for keratoconus, Kane formula, and Kane formula for keratoconus, for cataract with keratoconus in Japanese eyes. SETTING: Five surgical sites in Japan. DESIGN: A retrospective case series. METHODS: Eyes with keratoconus undergoing cataract surgery were included. Postoperative refraction was compared with the prediction by the formulas. Visual acuity, manifest spherical equivalent, prediction error (PE), and mean absolute errors (MAEs) were determined 1 month postoperatively. The PE within 0.50 diopter (D), 1.00 D, and 2.00 D were compared between IOL formulas. Subgroup analysis based on the steepest keratometry (stage 1, ≤ 48 D; stage 2, > 48 D and ≤ 53 D; and stage 3, > 53 D) was performed. The relationship between PE and preoperative biometric data were assessed. RESULTS: Fifty eyes were included. The MAE of the Barrett True-K for keratoconus, Kane keratoconus, and Kane formulas were significantly lower than that of Haigis. A statistically significant difference in the prediction accuracy within ± 0.50 D was found between Kane keratoconus and Haigis. The prediction accuracy of the Barrett True-K for keratoconus, SRK/T, and Kane within ± 1.00 D was statistically significant compared with that of Haigis. In stage 3, the Barrett True-K for keratoconus had a significantly lower MAE than SRK/T and Haigis. CONCLUSION: Keratoconus-specific formulas were more accurate than existing formulas in Japanese eyes. The Barrett True-K formula for keratoconus had higher prediction accuracy in severe keratoconus.


Assuntos
Topografia da Córnea , Ceratocone , Lentes Intraoculares , Refração Ocular , Acuidade Visual , Humanos , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Ceratocone/cirurgia , Estudos Retrospectivos , Feminino , Japão/epidemiologia , Refração Ocular/fisiologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Topografia da Córnea/métodos , Adulto , Biometria/métodos , Óptica e Fotônica , Idoso , Córnea/patologia , Córnea/cirurgia , Seguimentos
12.
Cont Lens Anterior Eye ; 46(2): 101794, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36513565

RESUMO

PURPOSE: To determine 1) the relative differences in optical quality of keratoconic eyes fitted with four routinely used CL designs and 2) the Zernike coefficients in the residual wavefront aberration map that may be responsible for differences in the optical quality of keratoconic eyes fitted with these CLs. METHODS: Wavefront aberrations over a 3-mm pupil diameter were measured without and with Kerasoft IC®, Rose K2®, conventional spherical Rigid Gas Permeable (RGP), and Scleral CLs in 15 mild to moderate keratoconic eyes (20 - 28 years) and under unaided viewing in 10 age-similar non-contact lens wearing controls. The resultant through-focus curves constructed for the logarithm of Neural Sharpness (logNS) Image Quality (IQ) metric were quantified in terms of peak value, best focus, and depth of focus. Sensitivity analyses determined the impact of the residual Zernike coefficients of keratoconic eyes fitted with CLs on the IQ of controls at emmetropic refraction. RESULTS: The peak IQ and depth of focus were similar with Rose K2®, conventional RGP, and Scleral CLs (p > 0.05, for all) but significantly better than Kerasoft IC® CLs (p < 0.01 for all). Best focus was similar across all four CLs (p > 0.2 for all). However, the IQ parameters of all the lenses remained significantly poorer than the controls (p < 0.01, for all). The IQ of the controls dropped to keratoconic levels with induced residual lower-order Zernike terms and 3rd-order coma across all lenses in the sensitivity analysis (p < 0.001). CONCLUSIONS: IQ of keratoconic eyes remain suboptimal with routinely dispensed CL designs, largely due to residual lower-order aberrations and coma, all relative to the controls. The performance drop appears greater for the Kerasoft IC® CL relative to the other CL designs. These results may provide the optical basis for psychophysical spatial visual performance reported earlier across these four CL designs for keratoconus.


Assuntos
Lentes de Contato , Processamento de Imagem Assistida por Computador , Ceratocone , Retina , Adulto , Humanos , Adulto Jovem , Estudos de Casos e Controles , Desenho de Equipamento , Ceratocone/diagnóstico por imagem , Ceratocone/fisiopatologia , Ceratocone/terapia , Retina/diagnóstico por imagem , Retina/fisiologia , Resultado do Tratamento
13.
Cornea ; 41(4): 456-461, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35244626

RESUMO

PURPOSE: The purpose of this study was to assess an intellectual disability (ID) cohort with keratoconus (KC) regarding ophthalmic (visual acuity and corneal tomography) and systemic characteristics and to describe an appropriate clinical algorithm for investigation and management of KC in this setting. METHODS: This was the retrospective cohort study of patients with ID (Down syndrome, autism, and other) in the cornea department of a tertiary referral ophthalmic hospital in Dublin, Ireland. Retrospective chart review was conducted on people with ID undergoing examination under anesthesia or crosslinking under general anesthetic. Key outcome data included corneal examination findings, corneal tomography, visual acuity, and examination findings (eg, type of ID, general anesthetic, and cardiac status). RESULTS: Mean age of the 24 patients was 31.9 years (66.7% male). ID type was Down syndrome (66.7%), autism (25%), and other (8.3%). KC was diagnosed in 98% of eyes, with 45.8% having untreatable advanced disease (57.1% of these bilateral), 39.6% amenable to corneal collagen crosslinking (35.7% of these bilateral), and 6.3% having corneal transplantation. Congenital heart defects were present in 37.5% of the Down syndrome group. There were no serious ocular or systemic adverse events. CONCLUSIONS: KC is strikingly prevalent in the ID population. Ireland has the highest rate of Down syndrome in Europe (26.3:10,000 live births). This group is rarely suitable for corneal transplantation, and corneal collagen crosslinking is an effective intervention to prevent progression to advanced KC in this already socially restricted group. We propose an algorithm for investigation/treatment and also recommend uniform pediatric KC screening/treatment in ID populations.


Assuntos
Transtorno do Espectro Autista/complicações , Transplante de Córnea , Reagentes de Ligações Cruzadas/uso terapêutico , Síndrome de Down/complicações , Deficiência Intelectual/complicações , Ceratocone/terapia , Adolescente , Adulto , Criança , Colágeno/metabolismo , Substância Própria/efeitos dos fármacos , Substância Própria/metabolismo , Topografia da Córnea , Feminino , Seguimentos , Humanos , Ceratocone/tratamento farmacológico , Ceratocone/fisiopatologia , Ceratocone/cirurgia , Masculino , Pessoa de Meia-Idade , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Retrospectivos , Riboflavina/uso terapêutico , Raios Ultravioleta , Acuidade Visual/fisiologia , Adulto Jovem
14.
Cornea ; 41(4): 450-455, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35244625

RESUMO

PURPOSE: The purpose of this study was to investigate 3-year changes in keratoconus (KC) indices to determine the indicators of KC progression compared with age-related changes in children aged 6 to 12 years. METHODS: In this report of the Shahroud Schoolchildren Eye Cohort Study, KC was diagnosed based on vision, refraction, tomography, and slitlamp examination findings. KC progression was defined as changes in refractive astigmatism or zonal maximum keratometry (Zonal Kmax-3 mm). Then, 3-year changes (Δ) in vision, refraction, and tomographic indices were compared between progressive KC and normal eyes. The best set of ∆parameters for distinguishing KC progression from age-related changes were determined using the area under curve (AUC). RESULTS: Eighteen KC eyes and 10,422 normal eyes were analyzed. All KC cases showed progression after 3 years. Δindices were statistically different between the 2 groups except corrected distance visual acuity, anterior radius of curvature, irregularity index, and KC percentage index. The best Δindices, in descending order of AUC value, were index of height decentration, Zonal Kmax-3 mm, refractive astigmatism, single point Kmax, and index of vertical asymmetry (all AUC > 0.9), followed by inferior-superior asymmetry, index of surface variance, minimum corneal thickness, index of height asymmetry, KC index, posterior radius of curvature, and Belin/Ambrósio total Deviation (AUC = 0.8-0.9). CONCLUSIONS: According to our findings, changes in index of height decentration, Zonal Kmax-3 mm, refractive astigmatism, single point Kmax, and index of vertical asymmetry are the best indices for detecting KC progression in children younger than 12 years.


Assuntos
Ceratocone/diagnóstico , Envelhecimento/fisiologia , Fenômenos Biomecânicos , Criança , Córnea/fisiopatologia , Paquimetria Corneana , Topografia da Córnea , Progressão da Doença , Feminino , Humanos , Ceratocone/epidemiologia , Ceratocone/fisiopatologia , Masculino , Prevalência , Curva ROC , Refração Ocular/fisiologia , Microscopia com Lâmpada de Fenda , Acuidade Visual/fisiologia
15.
PLoS One ; 17(2): e0263528, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35113959

RESUMO

PURPOSE: To evaluate predictors for success in corneal crosslinking (CXL) for keratoconus in a large cohort and extended follow-up. DESIGN: A retrospective study based on a prospectively built database. METHODS: Participants underwent CXL for keratoconus from 2007 to 2018. Statistical analysis was performed for patients with at least 1-year follow-up. We analyzed effects of CXL type (Epithelium-on or Epithelium-off and Accelerated (9mW/cm2@10min) or Standard (3mW/cm2@30min)) and pre-operative factors including age, gender, baseline LogMAR visual acuity (LogMARpre), maximal corneal power (Kmaxpre), pachymetry, refractive and topographic cylinders, spherical equivalent (SEpre), mean corneal power (MeanK) and follow-up time on outcome measures. The outcome measures were the final change of Kmax (Delta Kmax) and the final change in LogMAR visual acuity (Delta LogMAR). A more negative Delta Kmax or Delta LogMAR represents a favorable effect of crosslinking. RESULTS: 517 eyes had Kmax results, and 385 eyes had LogMAR results with more than one year follow-up. These eyes were included in the study. The mean follow-up time was 2.29 years. Mean Kmax decreased from 54.07±5.99 diopters to 52.84±5.66 diopters (p<0.001), and Mean LogMAR decreased from 0.28±0.20 to 0.25±0.21 (p<0.001). Non-accelerated epithelium-off CXL resulted in greater flattening of Kmax when compared with other protocols. Visual acuity improvement was similar when comparing different CXL protocols. Multivariate analysis showed four factors associated with negative Delta Kmax: high Kmaxpre, high SEpre, high MeanKpre, and non-accelerated procedure. Multivariate analysis showed three factors associated with negative Delta LogMAR: high LogMARpre, high SEpre, and Low MeanKpre. After excluding corneas with Kmaxpre >65 D or Pachymetry<400 microns, multivariate analysis showed that high Kmaxpre, high SEpre, and non-accelerated CXL were associated with negative Delta Kmax while high LogMARpre and high SEpre were associated with negative Delta LogMAR. CONCLUSION: CXL for keratoconus is a highly effective treatment, as evident by its effects on the outcome measures: Delta Kmax and Delta LogMAR. CXL was more successful in eyes with high Kmaxpre, high SEpre, and high LogMARpre, which express disease severity. The non-accelerated epithelium-off protocol was associated with greater flattening of corneal curvature but did not show a better effect on visual acuity as compared to the other CXL protocols.


Assuntos
Córnea/fisiopatologia , Reagentes de Ligações Cruzadas/farmacologia , Ceratocone/fisiopatologia , Adolescente , Adulto , Idoso , Paquimetria Corneana , Topografia da Córnea/métodos , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Refração Ocular , Estudos Retrospectivos , Riboflavina/uso terapêutico , Adulto Jovem
16.
PLoS One ; 17(2): e0263506, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35134078

RESUMO

Aspherical- and multi-curve rigid gas-permeable hard contact lenses (HCLs) have a flattened curve in the peripheral zone and are mostly used for patients with keratoconus who cannot wear glasses, soft contact lenses, or spherical HCLs. In this retrospective study, a total of 95 eyes of 77 patients who used aspherical- or multi-curve HCLs (mean age: 40.0 ± 11.0 years) were evaluated. This study examined the types of aspherical- and multi-curve HCLs, best-corrected visual acuity (BCVA) values before and after wearing HCLs, the association with the Amsler-Krumeich classification, duration of wear, corneal/conjunctival disorder, and the frequency of changing HCLs. There were 78 eyes that used aspherical-curve HCLs and 17 that used multi-curve HCLs. BCVA significantly improved from 0.42 logMAR to 0.06 logMAR after wearing either form of HCL. The Amsler-Krumeich classification showed that aspherical-curve HCLs were commonly used for patients with stage 2 keratoconus, and multi-curve HCLs were commonly used for stage 4 patients. The BCVA values were worse when the disease stage was more severe (stages 3 and 4) regardless of HCL type. The mean base curve of the lenses was steeper in multi-curve HCLs than in aspherical-curve HCLs. The more severe the disease stage, the steeper the base curve in both aspherical- and multi-curve HCLs. The duration of wear significantly improved from 2.1 h to 10.2 h, and corneal/conjunctival disorder similarly improved. The mean frequency of changing HCL types was 1.1 times. This study suggests that a flat peripheral curve design with aspherical- and multi-curve HCLs is useful for patients with keratoconus.


Assuntos
Lentes de Contato/tendências , Ceratocone/terapia , Adulto , Córnea/fisiologia , Topografia da Córnea/métodos , Feminino , Humanos , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acuidade Visual/fisiologia
17.
Exp Eye Res ; 216: 108959, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35074345

RESUMO

Kynurenine aminotransferases (KAT) are enzymes catalyzing formation of kynurenic acid (KYNA) from kynurenine. KYNA is a Janus-faced molecule of high biological activity. On the one hand KYNA was identified as a UV filter and neuroprotectant with free radical scavenging properties, but on the other hand it may contribute to photodamage of lens proteins resulting in cataract formation. Fuchs endothelial corneal dystrophy (FECD) and keratoconus (KC) are common, vision threatening corneal dystrophies whose etiology is not fully understood. In our previous works, we confirmed the presence of KATs in the human cornea together with GPR35, a receptor for KYNA. This prompted us to investigate the potential changes in the expression of three isoforms: KAT I, KAT II, and KAT III in normal and FECD- and KC-affected corneas. Immunohistochemistry accompanied by gene expression data mining revealed that the levels of neither KAT I, KAT II, nor KAT III are affected in FECD and KC. This constitutes evidence against the involvement of KATs in the pathophysiology of FECD and KC.


Assuntos
Distrofia Endotelial de Fuchs/fisiopatologia , Ceratocone/fisiopatologia , Transaminases/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Distrofia Endotelial de Fuchs/enzimologia , Perfilação da Expressão Gênica , Humanos , Imuno-Histoquímica , Ceratocone/enzimologia , Masculino , Pessoa de Meia-Idade , Receptores Acoplados a Proteínas G/metabolismo , Transaminases/genética
18.
Cornea ; 41(4): 435-442, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34267059

RESUMO

PURPOSE: The purpose of this study was to evaluate the efficacy and safety of implantation of a new continuous corneal ring in keratoconic corneas of an Iranian population. METHODS: This study was conducted on 95 contact lens-intolerant keratoconic eyes with clear central corneas. A continuous corneal ring, annular intrastromal corneal inlay (AICI), was inserted using femtosecond laser in all cases. Patients were followed up for 1, 3, and 12 months postsurgery. Visual and subjective refractive outcomes were evaluated in each examination. Besides, keratometry and aberrometric values were recorded before and 12 months after surgery. Finally, vector analysis of refractive astigmatism was performed using the Alpins method. RESULTS: The uncorrected and corrected distance visual acuities improved significantly 12 months after surgery from 0.91 ± 0.39 to 0.38 ± 0.22 (P < 0 0.001) and 0.33 ± 0.21 to 0.13 ± 0.11 logMAR (P < 0.001), respectively. Moreover, spherical and cylindrical refractive components reduced from -2.52 ± 2.62 to -0.76 ± 1.78 D (P < 0.001) and -4.14 ± 1.64 to -1.91 ± 1.18 D (P < 0.001), respectively. The mean anterior keratometry had a significant reduction 12 months after AICI insertion (P< 0.001). Primary coma and spherical aberration values showed a significant increase (both, P < 0.05). Our results showed 100% safety (safety index: 1.8) and 45% efficacy (efficacy index: 1). CONCLUSIONS: AICI implantation seemed to be a safe and effective procedure for improving visual acuity and refractive outcomes in subjects with keratoconus.


Assuntos
Substância Própria/cirurgia , Ceratocone/cirurgia , Próteses e Implantes , Implantação de Prótese/métodos , Aberrometria , Adulto , Topografia da Córnea , Aberrações de Frente de Onda da Córnea/fisiopatologia , Feminino , Seguimentos , Humanos , Irã (Geográfico) , Ceratocone/fisiopatologia , Masculino , Desenho de Prótese , Refração Ocular/fisiologia , Resultado do Tratamento , Acuidade Visual/fisiologia
19.
Cornea ; 41(2): 201-205, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34050066

RESUMO

PURPOSE: To compare surgical outcomes and intraoperative and postoperative complications of big-bubble deep anterior lamellar keratoplasty (DALK) in patients with and without a history of previous corneal collagen crosslinking (CXL) for keratoconus. METHODS: Patients with keratoconus who underwent DALK surgery with big-bubble technique between January 2013 and January 2018 were retrospectively reviewed. Operative findings, intraoperative and postoperative complications, and visual and refractive outcomes were recorded. Patients were divided into 2 groups: with previous CXL (CXL-DALK group: 27 eyes) and without previous CXL (DALK group: 50 eyes). All parameters were compared between groups. RESULTS: Big bubble was successfully achieved in 24 eyes (88.9%) in the CXL-DALK group and in 45 eyes (90.0%) in the DALK group (P = 0.87). Type 1 bubble was obtained in 22 eyes (91.7%) in the CXL-DALK group and in 42 eyes (93.3%) in the DALK group (P = 0.79). Intraoperative microperforation occurred in 3 eyes (11.1%) in the CXL-DALK group and in 5 eyes (10.0%) in the DALK group (P = 1). Visual and refractive outcomes were similar between groups. The mean endothelial cell loss rates were 5.7% ± 2.3 at 1 year and 10.2 ± 3.1 at 2 years in the CXL-DALK group and 6.4% ± 4.7 at 1 year and 10.9% ± 5.4 at 2 years in the DALK group. Postoperatively, persistent epithelial defect was the most common complication in both groups, and postoperative complication rates were similar between groups. CONCLUSIONS: Our results have shown that previous CXL treatment does not influence the success of bubble formation and does not increase intraoperative or postoperative complication rates of DALK surgery for keratoconus. The improvement in visual acuity and refractive errors and endothelial cell loss rates were similar between CXL treated and untreated eyes after 2 years of follow-up.


Assuntos
Córnea/cirurgia , Topografia da Córnea/métodos , Seguimentos , Ceratocone/cirurgia , Ceratoplastia Penetrante/métodos , Complicações Pós-Operatórias/epidemiologia , Refração Ocular/fisiologia , Adolescente , Adulto , Córnea/patologia , Feminino , Humanos , Incidência , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Turquia/epidemiologia , Acuidade Visual , Adulto Jovem
20.
Cornea ; 41(4): 408-416, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33859086

RESUMO

PURPOSE: The aim of this study was to assess the effect of corneal crosslinking on vision and keratometry in children and young adults with progressive keratoconus. METHODS: A retrospective medical records review of patients aged 22 years or younger with keratoconus who underwent corneal crosslinking between January 2013 and November 2019 at Byers Eye Institute at Stanford University was conducted. Outcome measures included logarithm of the Minimum Angle of Resolution corrected distance visual acuity (CDVA); keratometry, including maximum keratometry (Kmax); pachymetry; and total wavefront aberration. Measurements were taken at baseline and at 12 and 24 months postoperatively. RESULTS: Fifty-seven eyes of 49 patients aged 12 to 22 years were assessed. The mean preoperative CDVA was logarithm of the Minimum Angle of Resolution 0.38 ± 0.32 (20/48), with a mean postoperative CDVA of 0.29 ± 0.31 (20/39) and 0.31 ± 0.31 (20/41) at 12 and 24 months postoperatively, respectively. Compared with preoperative mean Kmax, there was an improvement of -0.8 diopters (D) to a mean postoperative Kmax of 59.1 ± 9.1 D at 12 months and -1.3 D to 59.7 ± 8.8 D at 24 months. Subanalysis excluding the second eye of patients who underwent bilateral crosslinking showed similar results. Linear mixed modeling showed significant improvement in Kmax at both 12 and 24 months postoperatively. Minimum central corneal thickness initially decreased but stabilized at 24 months after crosslinking. Total wavefront aberration remained stable. CONCLUSIONS: Corneal crosslinking stabilizes, and in some cases improves, visual and corneal parameters in pediatric and young adult patients with keratoconus. The procedure is safe and well-tolerated and may prevent keratoconus progression in young patients.


Assuntos
Colágeno/metabolismo , Reagentes de Ligações Cruzadas/uso terapêutico , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Riboflavina/uso terapêutico , Adolescente , Criança , Paquimetria Corneana , Substância Própria/efeitos dos fármacos , Substância Própria/metabolismo , Topografia da Córnea , Feminino , Humanos , Ceratocone/metabolismo , Ceratocone/fisiopatologia , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Raios Ultravioleta , Acuidade Visual/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA