Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 685
Filtrar
1.
Radiology ; 311(2): e231809, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38805729

RESUMO

HISTORY: A 45-year-old female patient who was previously healthy presented after several weeks of fullness in the right upper quadrant of the abdomen. The patient did not experience pain, nausea, vomiting, or jaundice, and had no contributory past medical or surgical history, including no history of malignancy. Upon examination, vital signs were within normal limits and the patient was appeared well with soft palpable fullness in the right upper quadrant. The abdomen was nontender and nondistended. Laboratory investigation revealed no abnormalities, with a normal complete blood cell count and normal serum tumor markers that included α-fetoprotein (<2.0 ng/mL; reference, <8.3 ng/mL), cancer antigen 19-9 (21.6 U/mL; reference, <35 U/mL), and carcinoembryonic antigen (1.3 ng/mL; reference, <5 ng/mL). CT of the abdomen and pelvis was performed with intravenous contrast material in the emergency department (Fig 1). Subsequently, combined MRI and MR cholangiopancreatography of the abdomen was performed with and without intravenous contrast material for further evaluation (Fig 2). CT of the chest performed during the same encounter was unremarkable.


Assuntos
Tomografia Computadorizada por Raios X , Humanos , Feminino , Pessoa de Meia-Idade , Diagnóstico Diferencial , Tomografia Computadorizada por Raios X/métodos , Colangiopancreatografia por Ressonância Magnética/métodos , Meios de Contraste , Imageamento por Ressonância Magnética/métodos
2.
Clin Radiol ; 79(7): 553-558, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38616474

RESUMO

AIMS: To develop an auto-categorization system based on machine learning for three-dimensional magnetic resonance cholangiopancreatography (3D MRCP) to detect choledocholithiasis from healthy and symptomatic individuals. MATERIALS AND METHODS: 3D MRCP sequences from 254 cases with common bile duct (CBD) stones and 251 cases with normal CBD were enrolled to train the 3D Convolutional Neural Network (3D-CNN) model. Then 184 patients from three different hospitals (91 with positive CBD stone and 93 with normal CBD) were prospectively included to test the performance of 3D-CNN. RESULTS: With a cutoff value of 0.2754, 3D-CNN achieved the sensitivity, specificity, and accuracy of 94.51%, 92.47%, and 93.48%, respectively. In the receiver operating characteristic curve analysis, the area under the curve (AUC) for the presence or absence of CBD stones was 0.974 (95% CI, 0.940-0.992). There was no significant difference in sensitivity, specificity, and accuracy between 3D-CNN and radiologists. In addition, the performance of 3D-CNN was also evaluated in the internal test set and the external test set, respectively. The internal test set yielded an accuracy of 94.74% and AUC of 0.974 (95% CI, 0.919-0.996), and the external test set yielded an accuracy of 92.13% and AUC of 0.970 (95% CI, 0.911-0.995). CONCLUSIONS: An artificial intelligence-assisted diagnostic system for CBD stones was constructed using 3D-CNN model for 3D MRCP images. The performance of 3D-CNN model was comparable to that of radiologists in diagnosing CBD stones. 3D-CNN model maintained high performance when applied to data from other hospitals.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Imageamento Tridimensional , Redes Neurais de Computação , Sensibilidade e Especificidade , Humanos , Colangiopancreatografia por Ressonância Magnética/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Imageamento Tridimensional/métodos , Adulto , Idoso , Cálculos Biliares/diagnóstico por imagem , Estudos Prospectivos , Ducto Colédoco/diagnóstico por imagem , Aprendizado de Máquina , Coledocolitíase/diagnóstico por imagem
3.
Int J Surg ; 110(4): 1975-1982, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38668656

RESUMO

BACKGROUND: This study aimed to develop an automated segmentation system for biliary structures using a deep learning model, based on data from magnetic resonance cholangiopancreatography (MRCP). MATERIALS AND METHODS: Living liver donors who underwent MRCP using the gradient and spin echo technique followed by three-dimensional modeling were eligible for this study. A three-dimensional residual U-Net model was implemented for the deep learning process. Data were divided into training and test sets at a 9:1 ratio. Performance was assessed using the dice similarity coefficient to compare the model's segmentation with the manually labeled ground truth. RESULTS: The study incorporated 250 cases. There was no difference in the baseline characteristics between the train set (n=225) and test set (n=25). The overall mean Dice Similarity Coefficient was 0.80±0.20 between the ground truth and inference result. The qualitative assessment of the model showed relatively high accuracy especially for the common bile duct (88%), common hepatic duct (92%), hilum (96%), right hepatic duct (100%), and left hepatic duct (96%), while the third-order branch of the right hepatic duct (18.2%) showed low accuracy. CONCLUSION: The developed automated segmentation model for biliary structures, utilizing MRCP data and deep learning techniques, demonstrated robust performance and holds potential for further advancements in automation.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Aprendizado Profundo , Imageamento Tridimensional , Transplante de Fígado , Doadores Vivos , Humanos , Colangiopancreatografia por Ressonância Magnética/métodos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Cuidados Pré-Operatórios/métodos , Fígado/diagnóstico por imagem , Fígado/anatomia & histologia , Estudos Retrospectivos
4.
Eur J Radiol ; 175: 111455, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38608499

RESUMO

PURPOSE: To assess the diagnostic value of abbreviated protocol (AP) MRI to detect the degeneration signs in branch-duct intraductal papillary mucinous neoplasms (BD-IPMNs) in patients undergoing a routine MRI follow-up. METHODS: This dual-center retrospective study include patients with BD-IPMN diagnosed on initial comprehensive protocol (CP) MRI who underwent routine MRI follow-up. CP included axial and coronal T2-weighted images (T2WI), axial T1-weighted images (T1WI) before and after contrast administration, 3D MR cholangiopancreatography (MRCP) and diffusion-weighted images (DWI). Two APs, eliminating dynamic sequences ± DWI, were extracted from CP. Two radiologists evaluated the APs separately for IPMN degeneration signs according to Fukuoka criteria and compared the results to the follow-up CP. In patients who underwent EUS, imaging findings were correlated with pathological results. Per-patient and per-lesion sensitivity, specificity, PPV, NPV, and accuracy of APs were calculated. Additionally, the acquisition time for different protocols was calculated. RESULTS: One hundred-fourteen patients (56.1 % women, median age: 71 years) with 256 lesions were included. Degeneration signs were observed in 24.6 % and 12.1 % per-patient and per-lesion, respectively. Regarding APs, the per patient sensitivity, specificity, PPV, NPV, and accuracy in the detection of the degeneration signs were 100 %, 93.5 %, 83.3 %, 100 %, and 95.1 %, respectively. No additional role for DWI was detected. AP without DWI economized nearly half of CP acquisition time (388 versus 663 s, respectively). CONCLUSION: AP can confidently replace CP for BD-IPMN follow-up with high sensitivity and PPV while offering benefits such as patient comfort, improved MRI accessibility, and reduced dedicated time for image analysis. DWI necessitates special consideration. CLINICAL RELEVANCE STATEMENT: Our data suggest that APs safely detect all degeneration signs of IPMN. While there is an overestimation of mural nodules due to the lack of contrast injection, this occurs in a negligible number of patients.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias Pancreáticas , Sensibilidade e Especificidade , Humanos , Feminino , Masculino , Idoso , Estudos Retrospectivos , Neoplasias Pancreáticas/diagnóstico por imagem , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Idoso de 80 Anos ou mais , Carcinoma Ductal Pancreático/diagnóstico por imagem , Adenocarcinoma Mucinoso/diagnóstico por imagem , Meios de Contraste , Neoplasias Intraductais Pancreáticas/diagnóstico por imagem , Colangiopancreatografia por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Imagem de Difusão por Ressonância Magnética/métodos
5.
Aliment Pharmacol Ther ; 59(11): 1366-1375, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38571284

RESUMO

BACKGROUND: Imaging markers of biliary disease in primary sclerosing cholangitis (PSC) have potential for use in clinical and trial disease monitoring. Herein, we evaluate how quantitative magnetic resonance cholangiopancreatography (MRCP) metrics change over time, as per the natural history of disease. METHODS: Individuals with PSC were prospectively scanned using non-contrast MRCP. Quantitative metrics were calculated using MRCP+ post-processing software to assess duct diameters and dilated and strictured regions. Additionally, a hepatopancreatobiliary radiologist (blinded to clinical details, biochemistry and quantitative biliary metrics) reported each scan, including ductal disease assessment according to the modified Amsterdam Cholangiographic Score (MAS). RESULTS: At baseline, 14 quantitative MRCP+ metrics were found to be significantly different in patients with PSC (N = 55) compared to those with primary biliary cholangitis (N = 55), autoimmune hepatitis (N = 57) and healthy controls (N = 18). In PSC specifically, baseline metrics quantifying the number of strictures and the number and length of bile ducts correlated with the MAS, transient elastography and serum ALP values (p < 0.01 for all correlations). Over a median 371-day follow-up (range: 364-462), 29 patients with PSC underwent repeat MRCP, of whom 15 exhibited quantitative changes in MRCP+ metrics. Compared to baseline, quantitative MRCP+ identified an increasing number of strictures over time (p < 0.05). Comparatively, no significant differences in biochemistry, elastography or the MAS were observed between timepoints. Quantitative MRCP+ metrics remained stable in non-PSC liver disease. CONCLUSION: Quantitative MRCP+ identifies changes in ductal disease over time in PSC, despite stability in biochemistry, liver stiffness and radiologist-derived cholangiographic assessment (trial registration: ISRCTN39463479).


Assuntos
Colangiopancreatografia por Ressonância Magnética , Colangite Esclerosante , Humanos , Colangite Esclerosante/diagnóstico por imagem , Colangiopancreatografia por Ressonância Magnética/métodos , Estudos Prospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Idoso , Ductos Biliares/diagnóstico por imagem , Ductos Biliares/patologia , Adulto Jovem
6.
Medicine (Baltimore) ; 103(8): e37283, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38394509

RESUMO

Main pancreatic duct (MPD) dilatation is reported to be a risk factor for pancreatic cancer (PC). Although magnetic resonance cholangiopancreatography (MRCP) and ultrasonographic modalities are valuable for monitoring the pancreas, there is limited information on the efficacy of different imaging modalities in measuring MPD diameter. To improve pancreatic imaging, we developed a specialized ultrasound approach focusing on the pancreas (special pancreatic US). We aimed to examine the correlation between MPD diameter measurements using special pancreatic US versus MRCP. We retrospectively reviewed the clinical data of patients with MPD dilation (≥2.5 mm) via special pancreatic US used for screening at our institution between January 2020 and October 2022 and included patients who underwent magnetic resonance imaging 2 months before and after pancreatic US. The MPD diameter on MRCP was measured at the pancreatic locus, where the maximum MPD diameter was obtained on special pancreatic US. This study included 96 patients, with a median interval of 8.5 days between the date of special pancreatic US and the date of undergoing MRCP. MPD dilatation and/or pancreatic cysts were diagnosed in 86 patients, PC in 5 patients, and other diseases in 5 patients. The median MPD diameter, measured using special pancreatic US, was 3.4 mm (interquartile range: 2.9-4.9 mm), whereas it was 3.5 mm using MRCP (interquartile range: 2.8-4.5 mm). There were strong positive correlations between MPD diameter measured on special pancreatic US and that measured on MRCP (R = 0.925, P < .001). This study revealed strong positive correlations between the MPD diameter measurements using special pancreatic US and MRCP. MPD diameter measurements from each imaging method can be helpful during follow-up in individuals at a high risk of PC.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Neoplasias Pancreáticas , Humanos , Colangiopancreatografia por Ressonância Magnética/métodos , Estudos Retrospectivos , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Ductos Pancreáticos/diagnóstico por imagem , Ductos Pancreáticos/patologia , Imageamento por Ressonância Magnética/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Ultrassonografia
7.
Acta Radiol ; 64(12): 2969-2976, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37807657

RESUMO

BACKGROUND: Magnetic resonance cholangiopancreatography (MRCP) may exhibit ghosting and blurring artifacts due to irregular breathing cycles, which can be overcome by shortening the shot duration. T2 preparation pulse enables heavy T2 contrast even with a shorter TE by use of the shortened shot duration; therefore, a technique using T2 preparation pulse combined with 3D turbo spin-echo MRCP (TPT-MRCP) was constructed. PURPOSE: To evaluate the clinical usefulness of TPT-MRCP in both navigation and breath-hold sequences compared to the conventional method. MATERIAL AND METHODS: We obtained navigation MRCP, which were TPT and conventional 3D turbo spin-echo in 37 patients, and breath-hold MRCP in 31 patients, which were TPT and gradient and spin echo. The quantitative evaluation included signal-to-noise ratio, contrast ratio, contrast-to-noise ratio and sharpness of the common bile duct in all sequences. Two radiologists visually evaluated image quality using a five-point grading method, assessing overall image quality and each of the six areas: common bile duct, right hepatic duct, left hepatic duct, main pancreatic duct, cystic duct and motion artifact. RESULTS: TPT-MRCP was significantly superior to conventional MRCP in all quantitative evaluations, except for signal-to-noise ratio in the navigation sequence. In the visual evaluation, TPT-MRCP provided higher image quality than the conventional technique in nearly all areas. The kappa (k) coefficient of the overall image quality was good for all sequences (κ = 0.61-0.8). CONCLUSION: TPT-MRCP provides higher image quality than conventional techniques in both navigation and breath-hold sequences. The present study demonstrates the greater clinical usefulness of TPT-MRCP.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Pancreatopatias , Humanos , Colangiopancreatografia por Ressonância Magnética/métodos , Pancreatopatias/patologia , Ductos Pancreáticos/diagnóstico por imagem , Ductos Pancreáticos/patologia , Fígado , Razão Sinal-Ruído , Imageamento Tridimensional/métodos
8.
Korean J Radiol ; 24(10): 983-995, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37793669

RESUMO

OBJECTIVE: To compare the diagnostic performance and interobserver agreement between contrast-enhanced computed tomography (CECT) and contrast-enhanced magnetic resonance imaging (CE-MRI) with magnetic resonance cholangiopancreatography (MRCP) for evaluating the resectability in patients with extrahepatic cholangiocarcinoma (eCCA). MATERIALS AND METHODS: This retrospective study included treatment-naïve patients with pathologically confirmed eCCA, who underwent both CECT and CE-MRI with MRCP using extracellular contrast media between January 2015 and December 2020. Among the 214 patients (146 males; mean age ± standard deviation, 68 ± 9 years) included, 121 (56.5%) had perihilar cholangiocarcinoma. R0 resection was achieved in 108 of the 153 (70.6%) patients who underwent curative-intent surgery. Four fellowship-trained radiologists independently reviewed the findings of both CECT and CE-MRI with MRCP to assess the local tumor extent and distant metastasis for determining resectability. The pooled area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of CECT and CE-MRI with MRCP were compared using clinical, surgical, and pathological findings as reference standards. The interobserver agreement of resectability was evaluated using Fleiss kappa (κ). RESULTS: No significant differences were observed between CECT and CE-MRI with MRCP in the pooled AUC (0.753 vs. 0.767), sensitivity (84.7% [366/432] vs. 90.3% [390/432]), and specificity (52.6% [223/424] vs. 51.4% [218/424]) (P > 0.05 for all). The AUC for determining resectability was higher when CECT and CE-MRI with MRCP were reviewed together than when CECT was reviewed alone in patients with discrepancies between the imaging modalities or with indeterminate resectability (0.798 [0.754-0.841] vs. 0.753 [0.697-0.808], P = 0.014). The interobserver agreement for overall resectability was fair for both CECT (κ = 0.323) and CE-MRI with MRCP (κ = 0.320), without a significant difference (P = 0.884). CONCLUSION: CECT and CE-MRI with MRCP showed no significant differences in the diagnostic performance and interobserver agreement in determining the resectability in patients with eCCA.


Assuntos
Neoplasias dos Ductos Biliares , Colangiocarcinoma , Masculino , Humanos , Colangiopancreatografia por Ressonância Magnética/métodos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Colangiocarcinoma/diagnóstico por imagem , Colangiocarcinoma/cirurgia , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Neoplasias dos Ductos Biliares/cirurgia , Ductos Biliares Intra-Hepáticos
9.
Eur Radiol ; 33(12): 9022-9037, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37470827

RESUMO

OBJECTIVES: PSC strictures are routinely diagnosed on T2-MRCP as dominant- (DS) or high-grade stricture (HGS). However, high inter-observer variability limits their utility. We introduce the "potential functional stricture" (PFS) on T1-weighted hepatobiliary-phase images of gadoxetic acid-enhanced MR cholangiography (T1-MRC) to assess inter-reader agreement on diagnosis, location, and prognostic value of PFS on T1-MRC vs. DS or HGS on T2-MRCP in PSC patients, using ERCP as the gold standard. METHODS: Six blinded readers independently reviewed 129 MRIs to diagnose and locate stricture, if present. DS/HGS was determined on T2-MRCP. On T1-MRC, PFS was diagnosed if no GA excretion was seen in the CBD, hilum or distal RHD, or LHD. If excretion was normal, "no functional stricture" (NFS) was diagnosed. T1-MRC diagnoses (NFS = 87; PFS = 42) were correlated with ERCP, clinical scores, labs, splenic volume, and clinical events. Statistical analyses included Kaplan-Meier curves and Cox regression. RESULTS: Interobserver agreement was almost perfect for NFS vs. PFS diagnosis, but fair to moderate for DS and HGS. Forty-four ERCPs in 129 patients (34.1%) were performed, 39 in PFS (92.9%), and, due to clinical suspicion, five in NFS (5.7%) patients. PFS and NFS diagnoses had 100% PPV and 100% NPV, respectively. Labs and clinical scores were significantly worse for PFS vs. NFS. PFS patients underwent more diagnostic and therapeutic ERCPs, experienced more clinical events, and reached significantly more endpoints (p < 0.001) than those with NFS. Multivariate analysis identified PFS as an independent risk factor for liver-related events. CONCLUSION: T1-MRC was superior to T2-MRCP for stricture diagnosis, stricture location, and prognostication. CLINICAL RELEVANCE STATEMENT: Because half of PSC patients will develop clinically-relevant strictures over the course of the disease, earlier more confident diagnosis and correct localization of functional stricture on gadoxetic acid-enhanced MRI may optimize management and improve prognostication. KEY POINTS: • There is no consensus regarding biliary stricture imaging features in PSC that have clinical relevance. • Twenty-minute T1-weighted MRC images correctly classified PSC patients with potential (PFS) vs with no functional stricture (NFS). • T1-MRC diagnoses may reduce the burden of diagnostic ERCPs.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Colangite Esclerosante , Humanos , Colangiopancreatografia por Ressonância Magnética/métodos , Constrição Patológica , Colangite Esclerosante/complicações , Colangite Esclerosante/diagnóstico por imagem , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Colangiopancreatografia Retrógrada Endoscópica
10.
Curr Probl Diagn Radiol ; 52(5): 372-376, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37263802

RESUMO

The purpose of this study was to address the variability in quality of magnetic resonance cholangiopancreatography (MRCP) images by examining differences in quality grades before and after modifying the MRCP protocol to include placement of physical bellows while scanning. This single institution quality improvement initiative included 727 MRCP examinations performed from July 2019 to December 2020 in patients 18 years and older. The Define, Measure, Analyze, Improve, and Control (DMAIC) strategy was utilized to explore factors related to MRCP image quality and identify solutions that could create effective change. Based on the results of this analysis, MRCP protocols were changed in December 2019 to include physical bellows. Examinations were grouped as occurring either pre- or postintervention as well as whether they occurred in an inpatient or outpatient setting. MRCP examinations were evaluated for quality and labeled either nondiagnostic or diagnostic. A logistic regression model was fit to compare the odds of a diagnostic QA grade between preintervention and postintervention groups and inpatient and outpatient settings. The preintervention group had 41.12% of MRCP studies of diagnostic quality, and the postintervention group had 60.57% of studies of diagnostic quality. The estimated odds of an image being of diagnostic quality in the postintervention group were 2.46 times the odds for the preintervention group across all departments and patient classes (P < 0.001). The estimated odds of an image being of diagnostic quality in the outpatient group were 2.01 times the odds for those in the inpatient group (P < 0.001). Utilizing a standardized quality improvement method can lead to sustained improvements in the diagnostic quality of MRCP studies.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Imageamento Tridimensional , Humanos , Colangiopancreatografia por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Exame Físico
11.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 79(7): 708-716, 2023 Jul 20.
Artigo em Japonês | MEDLINE | ID: mdl-37302819

RESUMO

Magnetic resonance cholangiopancreatography (MRCP) is a valuable non-invasive technique that depicts bile or pancreatic juice as hyperintense in heavily T2-weighted images. Data acquisition in the three-dimensional multi-slice MRCP method is acquired with respiratory triggered. Echo train duration (ETD) is the data acquisition time every breath is in inverse proportion to total acquisition time, and has influence of image contrast and spatial resolution in turbo spin echo (TSE) imaging. Therefore, the effects of image contrast and spatial resolution of three-dimensional heavily T2-weighted variable refocusing flip angle TSE images on ETD in fundamental and clinical settings were measured using a phantom. No significant difference was detected with regard to image contrasts. Increasing ETD reduced spatial resolution, but no significant difference was detected regarding visual evaluation in the fundamental setting. On the other hand, in some of the clinical settings, increasing ETD with phase partial Fourier (PPF) reduced spatial resolution. The study result indicates that changing ETD fitting respiratory state of individual examinee without PPF is useful for optimized acquisition time without sacrificing image contrast and spatial resolution.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Colangiopancreatografia por Ressonância Magnética/métodos , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos
12.
J Comput Assist Tomogr ; 47(4): 515-523, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37205734

RESUMO

PURPOSE: Ultrasound (US) is considered a first-line study for painless jaundice. However, in our hospital system, patients with new-onset painless jaundice often have a contrast-enhanced computed tomography (CECT) or magnetic resonance cholangiopancreatography (MRCP) regardless of the sonographic findings. Thus, we investigated the accuracy of US for detection of biliary dilatation in patients with new-onset painless jaundice. METHODS: Our electronic medical record was searched from January 1, 2012, to January 1, 2020, for adult patients with new-onset painless jaundice. Presenting complaint/setting, laboratory values, imaging studies/findings, and final diagnoses were recorded. Patients with pain or known liver disease were excluded. A gastrointestinal physician reviewed the laboratory values/chart to classify the type of suspected obstruction. Two radiologists blindly re-reviewed the US scans, and κ between the radiologists was calculated. Fisher exact test and the 2-sample t test were used for statistical analysis. RESULTS: Three hundred sixty patients presented with jaundice (>3 mg/dL), of whom 68 met the inclusion criteria (no pain and no known liver disease). Laboratory values had an overall accuracy of 54%, but were accurate in 87.5% and 85% for obstructing stones/pancreaticobiliary cancer. Ultrasound demonstrated overall accuracy of 78%, but only 69% for pancreaticobiliary cancer and 12.5% for common bile duct stone. Seventy-five percent of the patients underwent follow-up CECT or MRCP regardless of presenting setting. In the emergency department or inpatient setting, 92% of the patients underwent CECT or MRCP regardless of US, and 81% had follow-up CECT or MRCP within 24 hours. CONCLUSION: A US-first strategy in the setting of new-onset painless jaundice is accurate only 78% of the time. In practice, US was almost never a stand-alone imaging examination in patients presenting to the emergency department or inpatient setting with new-onset painless jaundice, no matter the suspected diagnosis based on clinical and laboratory grounds or on the US findings themselves. However, for milder elevations of unconjugated bilirubin (suspicious for Gilbert disease) in the outpatient setting, a US demonstrating lack of biliary dilatation was often a definitive study for exclusion of pathology.


Assuntos
Cálculos Biliares , Icterícia , Neoplasias , Adulto , Humanos , Colangiopancreatografia por Ressonância Magnética/métodos , Ultrassonografia , Icterícia/diagnóstico por imagem , Icterícia/etiologia , Colangiopancreatografia Retrógrada Endoscópica
13.
Eur Radiol ; 33(11): 7585-7594, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37178197

RESUMO

OBJECTIVES: To evaluate the image quality of the 3D hybrid profile order technique and deep-learning-based reconstruction (DLR) for 3D magnetic resonance cholangiopancreatography (MRCP) within a single breath-hold (BH) at 3 T magnetic resonance imaging (MRI). METHODS: This retrospective study included 32 patients with biliary and pancreatic disorders. BH images were reconstructed with and without DLR. The signal-to-noise ratio (SNR), contrast, contrast-to-noise ratio (CNR) between the common bile duct (CBD) and periductal tissues, and full width at half maximum (FWHM) of CBD on 3D-MRCP were evaluated quantitatively. Two radiologists scored image noise, contrast, artifacts, blur, and overall image quality of the three image types using a 4-point scale. Quantitative and qualitative scores were compared using the Friedman test and post hoc Nemenyi test. RESULTS: The SNR and CNR were not significantly different when under respiratory gating- and BH-MRCP without DLR. However, they were significantly higher under BH with DLR than under respiratory gating (SNR, p = 0.013; CNR, p = 0.027). The contrast and FWHM of MRCP under BH with and without DLR were lower than those under respiratory gating (contrast, p < 0.001; FWHM, p = 0.015). Qualitative scores for noise, blur, and overall image quality were higher under BH with DLR than those under respiratory gating (blur, p = 0.003; overall, p = 0.008). CONCLUSIONS: The combination of the 3D hybrid profile order technique and DLR is useful for MRCP within a single BH and does not lead to the deterioration of image quality and space resolution at 3 T MRI. CLINICAL RELEVANCE STATEMENT: Considering its advantages, this sequence might become the standard protocol for MRCP in clinical practice, at least at 3.0 T. KEY POINTS: • The 3D hybrid profile order can achieve MRCP within a single breath-hold without a decrease in spatial resolution. • The DLR significantly improved the CNR and SNR of BH-MRCP. • The 3D hybrid profile order technique with DLR reduces the deterioration of image quality in MRCP within a single breath-hold.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Aprendizado Profundo , Humanos , Colangiopancreatografia por Ressonância Magnética/métodos , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos
14.
Eur Radiol ; 33(9): 5933-5942, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37052657

RESUMO

OBJECTIVES: Bile leakage (BL) is a challenging complication after hepatobiliary surgery and liver trauma. Gadolinium ethoxybenzyl (Gd-EOB-DTPA)-enhanced magnetic resonance cholangiopancreatography (MRCP) is used to diagnose BL non-invasively. We assessed the value of Gd-EOB-DTPA-MRCP in the detection of postoperative and post-traumatic BL hypothesizing that exact identification of the leakage site is pivotal for treatment planning and outcome. METHODS: We retrospectively enrolled 39 trauma and postoperative patients who underwent Gd-EOB-DTPA-MRCP for suspected BL. Three readers rated the presence of BL and leakage site (intraparenchymal, central, peripheral ± aberrant or disconnected ducts). Imaging findings were compared to subsequent interventional procedures and their complexity and outcome. RESULTS: BL was detected in Gd-EOB-DTPA-MRCP in 25 of patients and was subsequently confirmed. Sites of BL differed significantly between postoperative (central [58%] and peripheral [42%]) and trauma patients (intraparenchymal [100%]; p < 0.001). Aberrant or disconnected ducts were diagnosed in 8%/26% of cases in the postoperative subgroup. Inter-rater agreement for the detection and localization of BL was almost perfect (Κ = 0.85 and 0.88; p < 0.001). Intraparenchymal BL required significantly less complex interventional procedures (p = 0.002), whereas hospitalization and mortality did not differ between the subgroups (p > 0.05). CONCLUSIONS: Gd-EOB-DTPA-MRCP reliably detects and exactly locates BL in postoperative and trauma patients. Exact localization of biliary injuries enables specific treatment planning, as intraparenchymal leakages, which occur more frequently after trauma, require less complex interventions than central or peripheral leaks in the postoperative setting. As a result of specific treatment based on exact BL localization, there was no difference in the duration of hospitalization or mortality. CLINICAL RELEVANCE STATEMENT: Gd-EOB-DTPA-MRCP is a reliable diagnostic tool for exactly localizing iatrogenic and post-traumatic biliary leakage. Its precise localization helps tailor local therapies for different injury patterns, resulting in comparable clinical outcomes despite varying treatments. KEY POINTS: • Gd-EOB-DTPA-MRCP enables adequate detection and localization of bile leakages in both postoperative and post-traumatic patients. • The site of bile leakage significantly impacts the complexity of required additional interventions. • Intraparenchymal bile leakage is commonly seen in patients with a history of liver trauma and requires less complex interventions than postoperative central or peripheral bile leakages, while hospitalization and mortality are similar.


Assuntos
Doenças Biliares , Neoplasias Hepáticas , Humanos , Colangiopancreatografia por Ressonância Magnética/métodos , Meios de Contraste , Estudos Retrospectivos , Bile , Gadolínio DTPA , Fígado/diagnóstico por imagem , Fígado/cirurgia , Fígado/patologia , Resultado do Tratamento , Imageamento por Ressonância Magnética/métodos
15.
Clin Imaging ; 97: 7-13, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36868034

RESUMO

INTRODUCTION: Adult Primary Sclerosing Cholangitis (PSC) subjects have worse outcomes compared to pediatric PSC subjects. The reasons for this observation are not completely understood. METHODS: In this single-center, retrospective (2005-17) study we compared clinical information, laboratory data, and previously published MRCP-based scores between 25 pediatric (0-18 years at diagnosis) and 45 adult (19 years and above) subjects with large duct PSC at the time of diagnosis. For each subject, radiologists determined MRCP-based parameters and scores after reviewing the MRCP images. RESULTS: The median age at diagnosis for pediatric subjects was 14 years, while that of adult subjects was 39 years. At the time of diagnosis, adult subjects had a higher incidence of biliary complications like cholangitis and high-grade biliary stricture (27% vs. 6%, p = 0.003) and higher serum bilirubin (0.8 vs. 0.4 mg/dl, p = 0.01). MRCP analysis showed that adult subjects had a higher incidence of hilar lymph node enlargement (24.4% vs. 4%, p = 0.03) at diagnosis. Adult subjects had worse sum-IHD score (p = 0.003) and average-IHD score (p = 0.03). Age at diagnosis correlated with higher average-IHD (p = 0.002) and sum-IHD (p = 0.002) scores. Adult subjects had worse Anali score without contrast (p = 0.01) at diagnosis. MRCP-based extrahepatic duct parameters and scores were similar between groups. DISCUSSION: Adult PSC subjects may have higher severity of disease at diagnosis compared to pediatric subjects. Future prospective cohort studies are required to confirm this hypothesis.


Assuntos
Sistema Biliar , Colangite Esclerosante , Doenças da Vesícula Biliar , Humanos , Adulto , Criança , Adolescente , Colangite Esclerosante/diagnóstico por imagem , Colangiopancreatografia por Ressonância Magnética/métodos , Estudos Retrospectivos , Sistema Biliar/patologia
16.
Eur Radiol ; 33(5): 3580-3591, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36884086

RESUMO

OBJECTIVES: To develop and validate a radiomics nomogram based on a fully automated pancreas segmentation to assess pancreatic exocrine function. Furthermore, we aimed to compare the performance of the radiomics nomogram with the pancreatic flow output rate (PFR) and conclude on the replacement of secretin-enhanced magnetic resonance cholangiopancreatography (S-MRCP) by the radiomics nomogram for pancreatic exocrine function assessment. METHODS: All participants underwent S-MRCP between April 2011 and December 2014 in this retrospective study. PFR was quantified using S-MRCP. Participants were divided into normal and pancreatic exocrine insufficiency (PEI) groups using the cut-off of 200 µg/L of fecal elastase-1. Two prediction models were developed including the clinical and non-enhanced T1-weighted imaging radiomics model. A multivariate logistic regression analysis was conducted to develop the prediction models. The models' performances were determined based on their discrimination, calibration, and clinical utility. RESULTS: A total of 159 participants (mean age [Formula: see text] standard deviation, 45 years [Formula: see text] 14;119 men) included 85 normal and 74 PEI. All the participants were divided into a training set comprising 119 consecutive patients and an independent validation set comprising 40 consecutive patients. The radiomics score was an independent risk factor for PEI (odds ratio = 11.69; p < 0.001). In the validation set, the radiomics nomogram exhibited the highest performance (AUC, 0.92) in PEI prediction, whereas the clinical nomogram and PFR had AUCs of 0.79 and 0.78, respectively. CONCLUSION: The radiomics nomogram accurately predicted pancreatic exocrine function and outperformed pancreatic flow output rate on S-MRCP in patients with chronic pancreatitis. KEY POINTS: • The clinical nomogram exhibited moderate performance in diagnosing pancreatic exocrine insufficiency. • The radiomics score was an independent risk factor for pancreatic exocrine insufficiency, and every point rise in the rad-score was associated with an 11.69-fold increase in pancreatic exocrine insufficiency risk. • The radiomics nomogram accurately predicted pancreatic exocrine function and outperformed the clinical model and pancreatic flow output rate quantified by secretin-enhanced magnetic resonance cholangiopancreatography on MRI in patients with chronic pancreatitis.


Assuntos
Insuficiência Pancreática Exócrina , Pancreatite Crônica , Humanos , Masculino , Pessoa de Meia-Idade , Colangiopancreatografia por Ressonância Magnética/métodos , Insuficiência Pancreática Exócrina/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Pancreatite Crônica/diagnóstico por imagem , Estudos Retrospectivos , Secretina , Feminino
17.
Abdom Radiol (NY) ; 48(6): 1921-1932, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36790454

RESUMO

The rising incidence combined with pregnancy-related physiological changes make gallbladder and biliary pathology high on the differential for pregnant patients presenting with right upper abdominal pain. Imaging plays a crucial role in determining surgical versus non-surgical management in pregnant patients with biliary or gallbladder pathology. Ultrasound (first-line) and magnetic resonance with magnetic resonance cholangiopancreatography (second-line) are the imaging techniques of choice in pregnant patients with suspected biliary pathology due to their lack of ionizing radiation. MRI/MRCP offers an excellent non-invasive imaging option, providing detailed anatomical detail without known harmful fetal side effects. This article reviews physiological changes in pregnancy that lead to gallstone and biliary pathology, key imaging findings on US and MRI/MRCP, and management pathways.


Assuntos
Sistema Biliar , Vesícula Biliar , Gravidez , Feminino , Humanos , Vesícula Biliar/diagnóstico por imagem , Vesícula Biliar/patologia , Colangiopancreatografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Ultrassonografia
18.
Curr Opin Gastroenterol ; 39(2): 59-66, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36821452

RESUMO

PURPOSE OF REVIEW: Magnetic resonance cholangiopancreatography (MRCP) has become the reference examination for the exploration of the biliary tract and has replaced endoscopic cholangiography for the analysis of the biliary tract because of its equivalent performance and its noninvasive character. RECENT FINDINGS: Based on the International Primary Sclerosing Cholangitis (PSC) Study Group recommendations for MR imaging in PSC, two protocols can be distinguished for the imaging of biliary tract: a basic protocol and a more complete protocol. It is essential to know the main pitfalls in order not to wrongly describe biliary anomalies. In addition to the excellent performance of MR imaging with MRCP in analyzing the anatomy and the anomalies of the biliary tree, complementary techniques have recently been developed. Several MR prognostic factors have been described. New hepato-specific contrast agents are now available for assessment of the general and segmental liver function. MR Elastography and Diffusion-weighted MR sequences are accurate to evaluate the degree of hepatic fibrosis. Finally, images obtained in MRCP can be postprocessed by a software that will analyze and model the biliary tree in order to quantitatively evaluate the biliary system. SUMMARY: Magnetic resonance imaging with its recent developments becomes by now an essential tool for the evaluation of biliary diseases.


Assuntos
Doenças dos Ductos Biliares , Sistema Biliar , Humanos , Colangiopancreatografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética
19.
Indian J Pediatr ; 90(12): 1210-1215, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36692816

RESUMO

OBJECTIVE: To compare the acquisition time, diagnostic efficacy, and image quality of the newer compressed SENSE 3D MRCP (CS-3D MRCP) with conventional 3D MRCP (C-3D MRCP) in children with pancreatitis. METHODS: A total of 24 children (2-17 y) diagnosed with pancreatitis were included in this study. The children underwent CS-3D MRCP and C-3D MRCP sequences. C-3D MRCP and CS-3D MRCP images were evaluated for the acquisition time duration, visualization of the pancreaticobiliary ducts, background suppression, image quality degradation by artifacts, and overall image quality by the two radiologists independently. Paired sample t-test was used to compare the acquisition time, the McNemar test for the image quality features, and the kappa coefficient was used for interobserver agreement. RESULTS: A two-fold decrease in the acquisition time of CS-3D MRCP (~148 ± 61 s) was seen, compared to C-3D MRCP (~310 ± 98 s), p < 0.001. The median scores for overall image quality on CS-3D MRCP and C-3D MRCP, respectively, were 2.05 ± 0.52 and 2.21 ± 0.53 (p = 0.18) for both radiologists. No significant difference was seen for the visibility of ducts, background suppression, and artifacts between the two radiologists, with substantial to almost perfect agreement seen for the different findings. CONCLUSION: The application of compressed SENSE 3D MRCP in children with pancreatitis results in a two-fold reduction in acquisition time with acceptable image quality. This may help in reducing the need for long sedation in children requiring anesthesia support for the MRCP and potentially help in reducing motion artifacts.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Pancreatite , Humanos , Criança , Colangiopancreatografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Artefatos
20.
Eur Radiol ; 33(6): 4333-4343, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36543903

RESUMO

OBJECTIVES: To compare the image quality of breath-hold magnetic resonance cholangiopancreatography (BH-MRCP) and respiratory-gating MRCP (RG-MRCP), and to explore breathing curve-based factors and patient-related data affecting image quality. METHODS: A total of 126 participants who underwent RG-MRCP and BH-MRCP on a 3-T magnetic resonance (MR) scanner were enrolled from May to December 2021. The images were evaluated by three radiologists on a 5-point scale. Respiratory parameters were extracted from the breathing curves. The Wilcoxon test was used to compare the image quality between the two MRCPs. Logistic regression analyzes were performed to identify age, sex, abdominal pain, and breathing predictor variables of better image quality. RESULTS: BH-MRCP performed better in visualizing intrahepatic bile ducts and overall image quality than RG-MRCP (p < 0.01). Factors predicting relatively good image quality included lower standard deviation of the respiratory amplitude (SDamp)-minimum-peak (odds ratio = 0.16, p < 0.01) for RG-MRCP and lower SDamp (OR = 0.69, p < 0.01) for BH-MRCP. CONCLUSIONS: BH-MRCP had significantly better overall image quality than RG-MRCP. Respiratory conditions exerted a significant impact on MRCP image quality, and parameters derived from the breathing curve could help predict the image quality of both sequences. KEY POINTS: • Both breath-hold (BH) and respiratory-gating (RG) MRCP demonstrate satisfying image quality. • BH-GRASE-MRCP is significantly better than RG-MRCP at the group level, but not for every individual. • Respiratory conditions exert a significant impact on the image quality, and the breathing curve can help predict the image quality.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Pancreatopatias , Humanos , Colangiopancreatografia por Ressonância Magnética/métodos , Estudos Prospectivos , Imageamento Tridimensional/métodos , Artefatos , Suspensão da Respiração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA