Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.209
Filtrar
1.
Medicine (Baltimore) ; 103(27): e38756, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38968488

RESUMO

Physical exercise requires integrated autonomic and cardiovascular adjustments to maintain homeostasis. We aimed to observe acute posture-related changes in blood pressure, and apply a portable noninvasive monitor to measure the heart index for detecting arrhythmia among elite participants of a 246-km mountain ultra-marathon. Nine experienced ultra-marathoners (8 males and 1 female) participating in the Run Across Taiwan Ultra-marathon in 2018 were enrolled. The runners' Heart Spectrum Blood Pressure Monitor measurements were obtained in the standing and supine positions before and immediately after the race. Their high-sensitivity troponin T and N-terminal proB-type natriuretic peptide levels were analyzed 1 week before and immediately after the event. Heart rate was differed significantly in the immediate postrace assessment compared to the prerace assessment, in both the standing (P = .011; d = 1.19) and supine positions (P = .008; d = 1.35). Postural hypotension occurred in 4 (44.4%) individuals immediately postrace. In 3 out of 9 (33.3%) recruited finishers, the occurrence of premature ventricular complex signals in the standing position was detected; premature ventricular complex signal effect was observed in the supine position postrace in only 1 participant (11.1%). Premature ventricular complex signal was positively correlated with running speed (P = .037). Of the 6 individuals who completed the biochemical tests postrace, 2 (33.3%) had high-sensitivity troponin T and 6 (100%) had N-terminal proB-type natriuretic peptide values above the reference interval. A statistically significant increase was observed in both the high-sensitivity troponin T (P = .028; d = 1.97), and N-terminal proB-type natriuretic peptide (P = .028; d = 2.91) levels postrace compared to prerace. In conclusion, significant alterations in blood pressure and heart rate were observed in the standing position, and postexercise (postural) hypotension occurred among ultra-marathoners. The incidence of premature ventricular complexes was higher after the race than before.


Assuntos
Sistema Nervoso Autônomo , Pressão Sanguínea , Frequência Cardíaca , Corrida de Maratona , Peptídeo Natriurético Encefálico , Troponina T , Humanos , Feminino , Masculino , Sistema Nervoso Autônomo/fisiologia , Frequência Cardíaca/fisiologia , Corrida de Maratona/fisiologia , Adulto , Troponina T/sangue , Pessoa de Meia-Idade , Pressão Sanguínea/fisiologia , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Taiwan , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/diagnóstico , Hipotensão Ortostática/fisiopatologia , Postura/fisiologia
3.
BMC Cardiovasc Disord ; 24(1): 316, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38910261

RESUMO

BACKGROUND AND AIMS: Electrophysiological characteristics and radiofrequency catheter ablation (RFCA) of premature ventricular contractions (PVCs) originating from the superior septal left ventricle (SSLV) have not yet been fully characterized. METHODS AND RESULTS: This study included 247 patients who underwent RFCA for PVCs arising from the ventricular outflow tract between February 2020 and August 2022. The successful ablation site was on the SSLV in 37 of the 247 patients. In 12 (32.4%) of those 37 patients, a low amplitude and high frequency spiky potential (SP) was recognized. Five patients showed a narrow QRS duration (86.8 ± 4.6 ms), with a discrete SP observed in PVCs and sinus rhythm, which showed an isoelectric line with the ventricular electrogram at the earliest activation site. Seven patients showed a wide QRS duration (131.6 ± 4.5 ms), with SP observed in PVCs without an isoelectric line with the ventricular electrogram. RFCA was successful at the site of the earliest SP in all 12 patients. The time from SP onset at the successful ablation site to the QRS onset (local activation time) was 30 ± 12 ms, which differed significantly from that for the remaining 25 patients withoutSP(22.1 ± 7.1 ms, P < 0.05). CONCLUSIONS: SPs were recorded in 12 (32.4%) of the 37 patients with PVCs originating from the SSLV. The morphology of the PVCs may show a narrow or wide QRS duration and the target site for successful ablation should be identified by the earliest SP.


Assuntos
Potenciais de Ação , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Complexos Ventriculares Prematuros , Humanos , Ablação por Cateter/efeitos adversos , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto , Fatores de Tempo , Estudos Retrospectivos , Idoso , Eletrocardiografia
4.
BMJ Case Rep ; 17(6)2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38839415

RESUMO

Ventricular tachycardia (VT) is a rare but potentially fatal complication in pregnancy. We present a case of a pregnant woman with cardiomyopathy due to frequent premature ventricular complexes (PVCs) and VT originating from the left ventricular outflow tract. After presenting late in the third trimester, the decision was made to deliver the fetus after 4 days of medication titration due to continued sustained episodes of VT. After delivery, the patient continued to have frequent PVCs and VT several months after discharge, and she ultimately underwent a PVC ablation with dramatic reduction in PVC burden and improvement in cardiomyopathy. Multidisciplinary planning with a pregnancy heart team led to appropriate contingency planning and a successful delivery. This case highlights how multidisciplinary management is best practice in pregnancy complicated by VT and the need for better diagnostic guidelines for PVC-induced cardiomyopathy in the setting of pregnancy.


Assuntos
Cardiomiopatias , Complicações Cardiovasculares na Gravidez , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Feminino , Gravidez , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiologia , Cardiomiopatias/terapia , Cardiomiopatias/complicações , Complicações Cardiovasculares na Gravidez/terapia , Complicações Cardiovasculares na Gravidez/diagnóstico , Adulto , Complexos Ventriculares Prematuros/terapia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/etiologia , Período Periparto , Ablação por Cateter , Eletrocardiografia , Antiarrítmicos/uso terapêutico , Antiarrítmicos/administração & dosagem
6.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38818846

RESUMO

AIMS: We aimed to assess the acute and midterm efficacy of premature ventricular contraction (PVC) ablation guided by multielectrode and point-by-point (PbP) mapping. METHODS AND RESULTS: This is a retrospective, international multicentre study of consecutive patients referred for PVC ablation in 10 hospital centres from January 2017 to December 2021. Based on the mapping approach, two cohorts were identified: the 'Multipolar group', where a dedicated high-density mapping catheter was employed, and the 'PbP group', where mapping was performed with the ablation catheter. Procedural endpoints, safety, and acute (procedural) and midterm efficacies were assessed. Of the 698 patients included in this study, 592 received activation mapping [46% males, median age of 55 (41-65) years]-248 patients in the Multipolar group and 344 patients in the PbP group. A higher number of activation points [432 (217-843) vs. 95 (42-185), P < 0.001], reduced mapping time (40 ± 38 vs. 61 ± 50 min, P < 0.001), and shorter procedure time (124 ± 60 vs. 143 ± 63 min, P < 0.001) were reported in the Multipolar group. Both groups had high acute success rates (84.7% with Multipolar mapping vs. 81.3% with PbP mapping, P = 0.63), as well as midterm efficacy (83.4% vs. 77.4%, P = 0.08), with no significant differences in the risk of adverse events (6.0% vs. 3.5%, P = 0.24). However, for left-sided PVC ablation specifically, there was a higher midterm efficacy in the Multipolar group (80.7% vs. 69.5%, P = 0.04), with multipolar mapping being an independent predictor of success [adjusted OR = 2.231 (95% CI, 1.476-5.108), P = 0.02]. CONCLUSION: The acute and midterm efficacies of PVC ablation are high with both multipolar and PbP mapping, although the former allows for quicker procedures and may potentially improve the outcomes of left-sided PVC ablation.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/diagnóstico , Masculino , Pessoa de Meia-Idade , Feminino , Ablação por Cateter/métodos , Estudos Retrospectivos , Idoso , Adulto , Resultado do Tratamento , Técnicas Eletrofisiológicas Cardíacas
8.
Clin Cardiol ; 47(4): e24266, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38587231

RESUMO

BACKGROUND: Electrocardiography (ECG) and 24 hours Holter monitoring (24 h-Holter) provided valuable information for premature ventricular and supraventricular contractions (PVC and PSVC). Currently, artificial intelligence (AI) based 2 hours single-lead Holter (2 h-Holter) monitoring may provide an improved strategy for PSVC/PVC diagnosis. HYPOTHESIS: AI combined with single-lead Holter monitoring improves PSVC/PVC detection. METHODS: In total, 170 patients were enrolled between August 2022 and 2023. All patients wore both devices simultaneously; then, we compared diagnostic efficiency, including the sensitivity/specificity/positive predictive-value (PPV) and negative predictive-value (NPV) in detecting PSVC/PVC by 24 h-Holter and 2 h-Holter. RESULTS: The PPV and NPV in patients underwent 2 h-Holter were 76.00%/87.50% and 96.35%/98.55, respectively, and the sensitivity and specificity were 79.17%/91.30%, and 95.65%/97.84% in PSVC/PVC detection compared with 24 h-Holter. The areas under the ROC curves (AUCs) for PSVC and PVC were 0.885 and 0.741, respectively (p < .0001). CONCLUSIONS: The potential advantages of the 2 h-Holter were shortened wearing period, improved convenience, and excellent consistency of diagnosis.


Assuntos
Eletrocardiografia Ambulatorial , Complexos Ventriculares Prematuros , Humanos , Inteligência Artificial , Complexos Ventriculares Prematuros/diagnóstico , Eletrocardiografia , Valor Preditivo dos Testes
9.
PLoS One ; 19(4): e0297551, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38593145

RESUMO

Arrhythmia is a life-threatening cardiac condition characterized by irregular heart rhythm. Early and accurate detection is crucial for effective treatment. However, single-lead electrocardiogram (ECG) methods have limited sensitivity and specificity. This study propose an improved ensemble learning approach for arrhythmia detection using multi-lead ECG data. Proposed method, based on a boosting algorithm, namely Fine Tuned Boosting (FTBO) model detects multiple arrhythmia classes. For the feature extraction, introduce a new technique that utilizes a sliding window with a window size of 5 R-peaks. This study compared it with other models, including bagging and stacking, and assessed the impact of parameter tuning. Rigorous experiments on the MIT-BIH arrhythmia database focused on Premature Ventricular Contraction (PVC), Atrial Premature Contraction (PAC), and Atrial Fibrillation (AF) have been performed. The results showed that the proposed method achieved high sensitivity, specificity, and accuracy for all three classes of arrhythmia. It accurately detected Atrial Fibrillation (AF) with 100% sensitivity and specificity. For Premature Ventricular Contraction (PVC) detection, it achieved 99% sensitivity and specificity in both leads. Similarly, for Atrial Premature Contraction (PAC) detection, proposed method achieved almost 96% sensitivity and specificity in both leads. The proposed method shows great potential for early arrhythmia detection using multi-lead ECG data.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Complexos Ventriculares Prematuros , Humanos , Fibrilação Atrial/diagnóstico , Complexos Ventriculares Prematuros/diagnóstico , Eletrocardiografia/métodos , Algoritmos , Complexos Atriais Prematuros/diagnóstico , Aprendizado de Máquina
10.
Clin Cardiol ; 47(3): e24250, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38450791

RESUMO

BACKGROUND: Catheter ablation has become one of the main treatment strategies in patients with premature ventricular complexes (PVC). The successful mapping and ablation can be performed with an ablation catheter without additional diagnostic catheters. HYPOTHESIS: We hypothesize that using a single catheter for PVC ablation may decrease complications, procedure time, and fluoroscopy exposure while maintaining comparable success rates. METHODS: Sixty-nine consecutive patients with PVC were treated with a single catheter approach compared to a historical cohort, in which a conventional setup was used. Propensity score matching was conducted with a 1:1 ratio. Outcome parameters included acute procedural success with elimination of all premature ventricular contractions after catheter ablation, procedural data as well as complication rates. RESULTS: Patients treated with a single catheter approach had shorter total procedure (60 minutes [IQR: 47,5-69,0 minutes] vs. 90 minutes [IQR 60-120 minutes]; p = 0.001) and fluoroscopy times (218 seconds [IQR: 110,5-446 seconds] vs. 310 seconds [IQR 190-640 seconds]; p = 0.012), which consecutively leads to a reduction of radiation exposure signified by a lower dose area product (155 cGycm² [IQR 74.4-334.5 cGycm²] vs. 368.4 cGycm² [IQR: 126-905.4 cGycm²]; p value 0.009). Acute procedural success rates were comparable in both groups (54 [84.3%] in the single catheter approach group and 58 [90.6%] in the conventional group; p: 0.287). CONCLUSION: A single catheter approach for the treatment of PVC is associated with a reduction of procedure- and fluoroscopy time, as well as a lesser radiation exposure, while maintaining equivalent acute success and complication rates compared with a conventionally used catheter setup.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Fluoroscopia , Pontuação de Propensão
13.
J Med Internet Res ; 26: e46098, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38512332

RESUMO

BACKGROUND: Wearable electrocardiogram (ECG) monitoring devices are used worldwide. However, data on the diagnostic yield of an adhesive single-lead ECG patch (SEP) to detect premature ventricular complex (PVC) and the optimal duration of wearing an SEP for PVC burden assessment are limited. OBJECTIVE: We aimed to validate the diagnostic yield of an SEP (mobiCARE MC-100, Seers Technology) for PVC detection and evaluate the PVC burden variation recorded by the SEP over a 3-day monitoring period. METHODS: This is a prospective study of patients with documented PVC on a 12-lead ECG. Patients underwent simultaneous ECG monitoring with the 24-hour Holter monitor and SEP on the first day. On the subsequent second and third days, ECG monitoring was continued using only SEP, and a 3-day extended monitoring was completed. The diagnostic yield of SEP for PVC detection was evaluated by comparison with the results obtained on the first day of Holter monitoring. The PVC burden monitored by SEP for 3 days was used to assess the daily and 6-hour PVC burden variations. The number of patients additionally identified to reach PVC thresholds of 10%, 15%, and 20% during the 3-day extended monitoring by SEP and the clinical factors associated with the higher PVC burden variations were explored. RESULTS: The recruited data of 134 monitored patients (mean age, 54.6 years; males, 45/134, 33.6%) were analyzed. The median daily PVC burden of these patients was 2.4% (IQR 0.2%-10.9%), as measured by the Holter monitor, and 3.3% (IQR 0.3%-11.7%), as measured in the 3-day monitoring by SEP. The daily PVC burden detected on the first day of SEP was in agreement with that of the Holter monitor: the mean difference was -0.07%, with 95% limits of agreement of -1.44% to 1.30%. A higher PVC burden on the first day was correlated with a higher daily (R2=0.34) and 6-hour burden variation (R2=0.48). Three-day monitoring by SEP identified 29% (12/42), 18% (10/56), and 7% (4/60) more patients reaching 10%, 15%, and 20% of daily PVC burden, respectively. Younger age was additionally associated with the identification of clinically significant PVC burden during the extended monitoring period (P=.02). CONCLUSIONS: We found that the mobiCARE MC-100 SEP accurately detects PVC with comparable diagnostic yield to the 24-hour Holter monitor. Performing 3-day PVC monitoring with SEP, especially among younger patients, may offer a pragmatic alternative for identifying more individuals exceeding the clinically significant PVC burden threshold.


Assuntos
Complexos Ventriculares Prematuros , Masculino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Complexos Ventriculares Prematuros/diagnóstico , Eletrocardiografia , Eletrocardiografia Ambulatorial , Tecnologia
14.
J Cardiovasc Med (Hagerstown) ; 25(4): 327-333, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38358902

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has become a largely used treatment for severe aortic stenosis. There are limited data, however, about predictors of long-term prognosis in this population. In this study, we assessed whether ventricular arrhythmias may predict clinical outcomes in patients undergoing TAVI. METHODS AND RESULTS: We performed a 24 h ECG Holter monitoring in 267 patients who underwent TAVI for severe aortic stenosis within 30 days from a successful procedure. The occurrence of frequent premature ventricular complexes (PVCs; ≥30/h), polymorphic PVCs and nonsustained ventricular tachycardia (NSVT) was obtained for each patient. Clinical outcome was obtained for 228 patients (85%), for an average follow-up of 3.5 years (range 1.0-8.6). Cardiovascular events (CVEs; cardiovascular death or resuscitated cardiac arrest) occurred in 26 patients (11.4%) and 63 patients died (27.6%). Frequent PVCs but not polymorphic PVCs and NSVT were found to be associated with CVEs at univariate analysis. Frequent PVCs were indeed found in 12 patients with (46.2%) and 35 without (17.3%) CVEs [hazard ratio 2.30; 95% confidence interval (CI) 1.03-5.09; P  = 0.04], whereas polymorphic PVCs were found in 11 (42.3%) and 54 (26.7%) patients of the two groups, respectively (hazard ratio 1.44; 95% CI 0.64-3.25; P  = 0.38), and NSVT in 9 (34.6%) and 43 patients of the two groups, respectively (hazard ratio 1.18; 95% CI 0.48-2.87; P  = 0.72). Frequent PVCs, however, were not significantly associated with CVEs at multivariate Cox regression analysis (hazard ratio 1.53; 95% CI 0.37-6.30; P  = 0.56). Both frequent PVCs, polymorphic PVCs and NSVT showed no significant association with mortality. CONCLUSION: In our study, the detection of frequent PVCs at Holter monitoring after TAVI was a predictor of CVEs (cardiovascular death/cardiac arrest), but this association was lost in multivariable analysis.


Assuntos
Estenose da Valva Aórtica , Parada Cardíaca , Taquicardia Ventricular , Substituição da Valva Aórtica Transcateter , Complexos Ventriculares Prematuros , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/epidemiologia , Complexos Ventriculares Prematuros/etiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/epidemiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Parada Cardíaca/diagnóstico , Parada Cardíaca/etiologia , Parada Cardíaca/terapia , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
16.
J Cardiovasc Electrophysiol ; 35(4): 856-861, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38297424

RESUMO

INTRODUCTION: With the entry of pulsed-field ablation (PFA) into electrophysiology, new possibilities for ablation of different substrates such as epicardial foci of premature ventricular contractions (PVCs) from coronary venous system (CVS) have been opened. METHODS: This article focuses on a case of a 27-year-old patient with frequent monomorphic PVCs of epicardial origin, treated by radiofrequency ablation, followed by PFA. RESULTS: After unsuccessful focus ablation through CVS with RFA, successful ablations from the same region with PFA were achieved. CONCLUSION: This is the first described case of successful ablation of epicardial PVCs using PFA, which we hope will help in defining indications for this novel technology and enhance quality of treatment for patients with different arrhythmias.


Assuntos
Ablação por Cateter , Seio Coronário , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Adulto , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ventrículos do Coração , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/etiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia
18.
Eur J Prev Cardiol ; 31(4): 486-495, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38198223

RESUMO

AIMS: Right bundle branch block (RBBB) morphology non-sustained ventricular arrhythmias (VAs) have been associated with the presence of non-ischaemic left ventricular scar (NLVS) in athletes. The aim of this cross-sectional study was to identify clinical and electrocardiogram (ECG) predictors of the presence of NLVS in athletes with RBBB VAs. METHODS AND RESULTS: Sixty-four athletes [median age 39 (24-53) years, 79% males] with non-sustained RBBB VAs underwent cardiac magnetic resonance (CMR) with late gadolinium enhancement in order to exclude the presence of a concealed structural heart disease. Thirty-six athletes (56%) showed NLVS at CMR and were assigned to the NLVS positive group, whereas 28 athletes (44%) to the NLVS negative group. Family history of cardiomyopathy and seven different ECG variables were statistically more prevalent in the NLVS positive group. At univariate analysis, seven ECG variables (low QRS voltages in limb leads, negative T waves in inferior leads, negative T waves in limb leads I-aVL, negative T waves in precordial leads V4-V6, presence of left posterior fascicular block, presence of pathologic Q waves, and poor R-wave progression in right precordial leads) proved to be statistically associated with the finding of NLVS; these were grouped together in a score. A score ≥2 was proved to be the optimal cut-off point, identifying NLVS athletes in 92% of cases and showing the best accuracy (86% sensitivity and 100% specificity, respectively). However, a cut-off ≥1 correctly identified all patients with NLVS (absence of false negatives). CONCLUSION: In athletes with RBBB morphology non-sustained VAs, specific ECG abnormalities at 12-lead ECG can help in detecting subjects with NLVS at CMR.


In athletes with right bundle branch block (RBBB) morphology non-sustained ventricular arrhythmias (VAs), the presence of a non-ischaemic left ventricular scar (NLVS) may be highly suspected if one or more of the following electrocardiogram (ECG) characteristics are present at the 12-lead resting ECG: low QRS voltages in limb leads, negative T waves in inferior leads, negative T waves in limb leads I­aVL, negative T waves in precordial leads V4­V6, presence of left posterior fascicular block, presence of pathologic Q waves, and poor R-wave progression in right precordial leads. This score should be externally validated in a larger population of athletes with VAs. In athletes with RBBB morphology non-sustained Vas, attention should be placed on the 12-lead resting ECG to suspect the presence of an NLVS. In athletes with RBBB VAs and the presence of one or more of the identified ECG characteristics, a cardiac magnetic resonance with late gadolinium enhancement is useful to rule out an NLVS.


Assuntos
Bloqueio de Ramo , Complexos Ventriculares Prematuros , Masculino , Humanos , Adulto , Feminino , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/etiologia , Cicatriz/patologia , Meios de Contraste , Estudos Transversais , Gadolínio , Eletrocardiografia
19.
J Cardiovasc Electrophysiol ; 35(3): 574-582, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37676022

RESUMO

INTRODUCTION: Premature ventricular complexes (PVCs) are the most common ventricular arrhythmia that are encountered in the clinical practice. Recent data suggests that high PVC burden may lead to the development of PVC-induced cardiomyopathy (PVC-CM) even in patients without structural heart disease. Treatment for effective suppression of PVCs, can reverse PVC-CM. Both antiarrhythmic drugs (AADs) and catheter ablation (CA) are recognized treatment modalities for any cardiac arrhythmias. However, with increasing preference of CA, the role of AADs needs further defining regarding their efficacy, safety, indications and patient selection to treat PVC-CM. METHODS: To ascertain the role of AADs to treat PVC-CM; whether they are indicated to treat PVC-CM, and if so, when, we interrogated PubMed and other search engines for English language publications with key words premature ventricular complexes (PVCs), cardiomyopathy, anti-arrhythmic drugs, catheter ablation, and pharmacological agents. All publications were carefully reviewed and scrutinized by the authors for their inclusion in the review paper. For illustration of cases, ethical standard was observed as per the 1975 Declaration of Helsinki, and the patient was treated as per the prevailing standard of care. Informed consent was obtained from the patient for conducting the ablation procedure. RESULTS: Our literature search specifically the pharmacological treatment of PVC-CM with AADs revealed significant paradigm shift in treatment approach for PVCs and PVC-induced cardiomyopathy. No major large, randomized control trials of AADs versus CA for PVC-CM were found. We found that beta-blockers and calcium channel blockers are particularly effective in the treatment of PVCs originating from right ventricular outflow tract. For Class Ic AADs - flecainide and propafenone, small clinical studies showed Class Ic AADs to be effective in PVC suppression, but their usage was not recommended in patients with significant coronary artery disease. Mexiletine was found to have modest effect on PVC suppression. Studies showed sotalol to significantly reduce PVCs frequency in patients receiving both low and high doses. Studies also showed amiodarone to have higher successful PVC suppression, but not recommended as a first-line treatment for patients with idiopathic PVCs in the absence of symptoms and left ventricular dysfunction. For dronedarone, no major clinical data were available. CONCLUSIONS: Based on the available data in the literature, we conclude that AADs play important role in the treatment of PVC-induced cardiomyopathy. However, appropriate patient selection criteria are vitally important, and in general terms AADs are indicated or polymorphic PVCs, epicardial PVCs; and when CA procedure is contraindicated, or not feasible or failed.


Assuntos
Cardiomiopatias , Ablação por Cateter , Disfunção Ventricular Esquerda , Complexos Ventriculares Prematuros , Humanos , Antiarrítmicos/efeitos adversos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/tratamento farmacológico , Complexos Ventriculares Prematuros/cirurgia , Volume Sistólico , Cardiomiopatias/diagnóstico , Cardiomiopatias/tratamento farmacológico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
20.
J Interv Card Electrophysiol ; 67(3): 457-470, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37097585

RESUMO

BACKGROUND: Premature ventricular contraction (PVC) is a type of cardiac arrhythmia that originates from ectopic pacemaker in the ventricles. The localization of the origin of PVC is essential for successful catheter ablation. However, most studies on non-invasive PVC localization focus on elaborate localization in specific regions of the ventricle. This study aims to propose a machine learning algorithm based on 12-lead electrocardiogram (ECG) data that can improve the accuracy of PVC localization in the whole ventricle. METHODS: We collected 12-lead ECG data from 249 patients with spontaneous or pacing-induced PVCs. The ventricle was divided into 11 segments. In this paper, we propose a machine learning method consisting of two consecutive classification steps. In the first classification step, each PVC beat was labeled to one of the 11 ventricular segments using six features, including a newly proposed morphological feature called "Peak_index." Four machine learning methods were tested for comparative multi-classification performance and the best classifier result was kept to the next step. In the second classification step, a binary classifier was trained using a smaller combination of features to further differentiate segments that are easily confused. RESULTS: The Peak_index as a proposed new classification feature combined with other features is suitable for whole ventricle classification by machine learning methods. The test accuracy of the first classification reached 75.87%. It is shown that a second classification for confusable categories can improve the classification results. After the second classification, the test accuracy reached 76.84%, and when a sample classified into adjacent segments was considered correct, the test "rank accuracy" was improved to 93.49%. The binary classification corrected 10% of the confused samples. CONCLUSION: This paper proposes a "two-step classification" method to localize the origin of PVC beats into the 11 regions of the ventricle using non-invasive 12-lead ECG. It is expected to be a promising technique to be used in clinical settings to help guide ablation procedures.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Eletrocardiografia/métodos , Ventrículos do Coração , Algoritmos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA