Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.166
Filtrar
1.
Braz J Cardiovasc Surg ; 39(4): e20230278, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748990

RESUMO

CLINICAL DATA: Female, seven years old, referred to our service complaining about congestive heart failure symptoms due to mitral valve regurgitation and atrial septal defect. Technical description: Echocardiographic findings compatible with Barlow's disease and atrial septal defect, ostium secundum type. OPERATION: She was submitted to mitral valvuloplasty with chordal shortening and prosthetic posterior ring (Gregori-Braile®) along with patch atrioseptoplasty. COMMENTS: Mitral valve regurgitation is a rare congenital heart disease and Barlow's disease is probably rarer. Mitral valve repair is the treatment of choice.


Assuntos
Comunicação Interatrial , Insuficiência da Valva Mitral , Humanos , Comunicação Interatrial/cirurgia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/complicações , Feminino , Criança , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Ecocardiografia , Prolapso da Valva Mitral/cirurgia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/complicações
3.
Echocardiography ; 41(5): e15823, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38678585

RESUMO

The morphologic features of the multiple atrial septal defects assessed by TTE-based 3D imaging were similar to those by 3D-TEE. TTE-based 3D model had excellent visibility, allowing observation of 3D structure of the rims of the defects. It may be useful method for assessment of the multiple atrial septal defects.


Assuntos
Ecocardiografia Tridimensional , Comunicação Interatrial , Veia Cava Inferior , Humanos , Comunicação Interatrial/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Veia Cava Inferior/diagnóstico por imagem , Feminino , Masculino , Adulto
5.
J Cardiovasc Med (Hagerstown) ; 25(4): 311-317, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38488065

RESUMO

AIMS: We present the experience and long-term results of intracardiac echocardiography (ICE)-guided closure of ostium secundum atrial septal defects (ASDs) in two Italian centers and investigate its systematic applicability as the gold standard in routine clinical practice. METHODS: We retrospectively evaluated all consecutive patients who underwent an ASD percutaneous closure procedure from March 2008 to February 2020. All patients underwent a preprocedural transesophageal echocardiography (TEE) evaluation. The closures were carried out under fluoroscopic and ICE guidance. A follow-up visit was performed at 1, 3 and 12 months, followed by telephone evaluations approximately every 2 years. RESULTS: Sixty-six patients (29% male individuals), mean age 43 ±â€Š16 years, were treated. In 15 cases, the TEE defect diameter was less than 10 mm, and in 8 of these patients, the ICE intraprocedural sizing increased the maximum diameter by more than 5 mm. Sizing balloon of the defect was performed in 51 cases; 2 patients received an ASD 38 mm device. Eight patients had multiple defects; in three of these, it was necessary to apply two devices. Four patients showed nonsignificant residual shunt; no complications related to the use of ICE were observed. One patient presented the migration of the ASD device into the abdominal aorta, percutaneously retrieved with a snare. No major complications were recorded during the entire follow-up period. CONCLUSION: This study confirms that ICE monitoring during ASD percutaneous closure is well tolerated and effective; it might be achievable as a routine gold standard by operators willing to use ICE systematically in all transcatheter closure interventions of interatrial communications.


Assuntos
Cateterismo Cardíaco , Comunicação Interatrial , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/terapia , Ecocardiografia Transesofagiana , Fluoroscopia , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 103(5): 741-750, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38451154

RESUMO

BACKGROUND: The GCA is a well performing device in terms of efficacy despite complex anatomies (aortic rim <5 mm and ASD diameter >17 mm) with a good safety profile. AIMS: To evaluate atrial septal defect (ASD) features impacting on right disc device thrombosis in patients who underwent Gore Cardioform ASD Occluder (GCA) implantation. METHODS: A total of 44 consecutive patients undergoing percutaneous ASD with GCA device from January 2020 to September 2022 at our tertiary care Center were evaluated. The minimum follow-up was 6 months. RESULTS: The patients were stratified in two groups according to a cut-off value of ASD diameter equal to 20 mm at sizing balloon, derived from ROC analysis (AUC = 0.894; p = 0.024). Baseline characteristics were comparable between groups in terms of age, sex, weight, height, and interatrial septum dimensions. Patients with ASD > 20 mm (n = 9) had a higher ASD/device dimension ratio, both at echocardiography (p = 0.009) and at sizing balloon (p = 0.001), longer fluoroscopic time (p = 0.022), and higher incidence of device thrombosis (0.006). Right disc thrombosis was observed in three patients of the ASD > 20 mm group, always in the inferior portion of the right disc. On univariate analysis, ASD diameter at sizing balloon (OR 1.360; p = 0.036) was the only positive predictor of device thrombosis. CONCLUSIONS: Right disc thrombosis of the GCA device may be under-recognized at follow-up, hence deserving clinical attention, especially in those patients with larger ASD diameters.


Assuntos
Comunicação Interatrial , Dispositivo para Oclusão Septal , Humanos , Ecocardiografia Transesofagiana , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/terapia
8.
J Stroke Cerebrovasc Dis ; 33(6): 107664, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38428550

RESUMO

OBJECTIVES: Paradoxical embolism from right-to-left shunt through atrial septal defect (ASD) and patent foramen ovale (PFO) is a well-accepted cause of "cryptogenic" strokes (CS). To better understand the pathogenic role of ASD, we compared ASD patients with CS having a high and low likelihood of being PFO-related. METHODS: In the Acute Stroke Registry and Analysis of Lausanne, we calculated prevalence of PFO and ASD in CS patients undergoing echocardiography, and calculated odds ratios (OR) when compared to non-CS. Using the Risk of Paradoxical Embolism (RoPE) score, we divided CS PFO patients in high (HL-PFO, RoPE 8-10) and low-likelihood (LL-PFO, RoPE 0-4) PFO-related stroke. We then performed univariate comparison of epidemiological, clinical and radiological variables of ASD patients with both PFO groups. RESULTS: Among all CS, prevalence of ASD and PFO were 1.3% and 36.8% respectively. When compared to non-CS, ASD and PFO were associated with CS (OR of 5.2, CI= 1.6-16.6, and 2.8, CI= 2.1-3.8). Compared with HL-PFO, ASD patients were older, more often female, had more cardiovascular risk factors and silent strokes. Compared with LL-PFO, ASD patients were younger, more often female, and had less risk factors. No differences were found for clinical and radiological characteristics and clinical outcome. CONCLUSION: ASD is a rare stroke risk factor for CS. Since characteristics of such patients lie in-between high and low-likelihood paradoxical PFO-strokes, a thorough work-up for other stroke mechanisms is warranted. Individual evaluation of the likelihood of the ASD being causative for stroke may be preferable over routine ASD closure.


Assuntos
Embolia Paradoxal , Forame Oval Patente , Comunicação Interatrial , Sistema de Registros , Humanos , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/complicações , Forame Oval Patente/epidemiologia , Feminino , Masculino , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/epidemiologia , Comunicação Interatrial/complicações , Fatores de Risco , Pessoa de Meia-Idade , Prevalência , Idoso , Embolia Paradoxal/epidemiologia , Embolia Paradoxal/diagnóstico por imagem , Embolia Paradoxal/etiologia , Medição de Risco , Adulto , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/diagnóstico por imagem
11.
Cardiol Young ; 34(4): 919-921, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38410075

RESUMO

We report an uncommon case report of total anomalous pulmonary venous returns into the right atrium at the base of the superior caval vein's ostium without a sinus venosus defect, in situs solitus, without vertical vein or a posterior pulmonary venous confluence.


Assuntos
Comunicação Interatrial , Veias Pulmonares , Síndrome de Cimitarra , Humanos , Síndrome de Cimitarra/diagnóstico por imagem , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/anormalidades , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/anormalidades , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/anormalidades
12.
Pediatr Cardiol ; 45(4): 710-721, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38366300

RESUMO

Atrial septal defects (ASDs) are common in neonates. Although past studies suggest ASDs  ≥ 3 mm in term neonates (TNs) are less likely to close, there is paucity of data regarding the natural history in preterm neonates (PNs), information that would inform surveillance. We sought to compare spontaneous closure rates and need for intervention for ASDs in TNs/near term (≥ 36 weeks) versus PNs (< 36 weeks). We included all TNs and PNs who underwent echocardiography at ≤ 1 month between 2010 and 2018 in our institution with an ASD ≥ 3 mm, without major congenital heart disease, and with repeat echocardiogram(s). Spontaneous resolution was defined as size diminution to < 3 mm or closure. We included 156 TNs (mean gestational age at birth 38.6 ± 1.4 weeks) and 156 PNs (29.6 ± 3.7 weeks) with a mean age at follow-up of 16 ± 19 and 15 ± 21 months, respectively (p = 0.76). Based on maximum color Doppler diameter, in TNs, ASD resolution occurred in 95% of small (3-5 mm), 87% of moderate (5.1-8 mm), and 60% of large (> 8 mm) defects; whereas, in PNs, resolution occurred in 79% of small, 76% of moderate, and 33% of large ASDs. There was a significant association between size and ASD resolution in TNs (p = 0.003), but not PNs (p = 0.17). Overall, ASD resolution rate was higher in TNs (89%) versus PNs (78%) (p = 0.009), and fewer TNs (1%) compared to PNs (7%) required ASD intervention (p = 0.02). Most ASDs identified in TNs and PNs spontaneously resolve. PNs, however, demonstrate lower ASD resolution and higher intervention rates within all size groups. These data should inform follow-up of affected neonates.


Assuntos
Comunicação Interatrial , Recém-Nascido , Humanos , Comunicação Interatrial/diagnóstico por imagem , Ecocardiografia , Ultrassonografia Doppler em Cores , Resultado do Tratamento , Cateterismo Cardíaco
15.
Int Heart J ; 65(1): 155-158, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38296570

RESUMO

Unroofed coronary sinus syndrome is a rare congenital cardiac anomaly, involving some anatomical variations. Approximately 60% of patients with unroofed coronary sinus syndrome have a concomitant atrial septal defect, which is termed unroofed coronary sinus atrial septal defect (CSASD). The precise detection of these abnormalities has been usually difficult with conventional echocardiography, mostly due to its small and complex structures. Herein, we report a case with unroofed coronary sinus atrial septal defect, in which preoperative contrast-enhanced computed tomography (CT) was useful in the operative decision making. We successfully repaired the defective roof of the coronary sinus with a bovine patch, while eliminating the inter-atrial shunt. The patient's postoperative course was uneventful with no residual shunt.


Assuntos
Seio Coronário , Cardiopatias Congênitas , Comunicação Interatrial , Idoso , Humanos , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Seio Coronário/anormalidades , Ecocardiografia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Síndrome , Tomografia Computadorizada por Raios X
18.
Echocardiography ; 41(1): e15724, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38064288

RESUMO

BACKGROUND AND AIM: Our aim was to evaluate the fluoroscopy time (FT), procedure time (PT) safety and efficacy when using intracardiac echocardiography (ICE) in comparison to transesophageal echocardiography (TEE) guidance for transcatheter closure of Ostium Secundum Atrial Septal Defect (OS-ASD). METHOD: Ninety patients (n = 90) diagnosed with OS-ASD underwent transcatheter closure between March 2006 and October 2021. Fifty-seven patients were treated under ICE guidance, while 33 patients were treated under TEE guidance. RESULTS: Mean age was 43 ± 15 years and 42 ± 10 years in the ICE and TEE groups, respectively. The majority of patients had a centrally placed defect. Median FT was 8.40 min versus 11.70 min (p < .001) in the ICE group compared to the TEE group, respectively. Median PT was 43 min versus 94 min (p < .001) in the ICE group compared to the TEE group, respectively. Both ICE and TEE provided high quality images. All interventions were completed successfully, except for one patient in the ICE group who experienced a device migration, the development of atrial tachycardia in one patient and atrial fibrillation in two patients in the ICE group which spontaneously cardioverted. There were no other complications. CONCLUSION: This study on a consistent cohort of patients with OS-ASD undergoing percutaneous closure suggests that use of ICE is safe and efficacious. Compared to TEE, ICE demonstrated significantly shorter FT and PT, decreasing the entire duration of the procedure and x-ray exposure. No relevant differences were observed in terms of success rate and complications.


Assuntos
Fibrilação Atrial , Comunicação Interatrial , Humanos , Adulto , Pessoa de Meia-Idade , Ecocardiografia Transesofagiana/métodos , Cateterismo Cardíaco/métodos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Fluoroscopia , Resultado do Tratamento
19.
Eur J Intern Med ; 120: 25-28, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38072687

RESUMO

Atrial septal defects (ASD) and Patent foramen ovale (PFO) represent the most common congenital heart diseases (CHD) adulthood. These two clinical entities, having different embryological origin, as well as clinical manifestations, clinical course and treatment must be carefully distinguished. Right heart failure and pulmonary hypertension are considered the major determinants of morbidity and mortality in ASD. Conversely, new pathophysiology concepts have been raised in the management of PFO as left atrium cardiopathy. New diagnostic tools, including cardiac magnetic resonance and intracardiac echocardiography have joint transthoracic and transesophageal echocardiography in the diagnostic definition of both ASD and PFO as well as in guiding their percutaneous closure. Moreover, several innovations have been developed in the field of percutaneous ASD and PFO closure devices including new evidence supporting the safety and efficacy of device-based closure. Aim of the present review is to present review we provided and update overview on ASD and PFO, focusing on the novel concepts regarding their pathophysiological and therapeutic aspects.


Assuntos
Forame Oval Patente , Comunicação Interatrial , Dispositivo para Oclusão Septal , Humanos , Adulto , Resultado do Tratamento , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/cirurgia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Ecocardiografia Transesofagiana , Átrios do Coração/diagnóstico por imagem , Cateterismo Cardíaco
20.
Radiol Med ; 129(1): 48-55, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38082195

RESUMO

OBJECT: The purpose of this study was to explore a machine learning-based residual networks (ResNets) model to detect atrial septal defect (ASD) on chest radiographs. METHODS: This retrospective study included chest radiographs consecutively collected at our hospital from June 2017 to May 2022. Qualified chest radiographs were obtained from patients who had finished echocardiography. These chest radiographs were labeled as positive or negative for ASD based on the echocardiographic reports and were divided into training, validation, and test dataset. Six ResNets models were employed to examine and compare by using the training dataset and was tuned using the validation dataset. The area under the curve, recall, precision and F1-score were taken as the evaluation metrics for classification result in the test dataset. Visualizing regions of interest for the ResNets models using heat maps. RESULTS: This study included a total of 2105 chest radiographs of children with ASD (mean age 4.14 ± 2.73 years, 54% male), patients were randomly assigned to training, validation, and test dataset with an 8:1:1 ratio. Healthy children's images were supplemented to three datasets in a 1:1 ratio with ASD patients. Following the training, ResNet-10t and ResNet-18D have a better estimation performance, with precision, recall, accuracy, F1-score, and the area under the curve being (0.92, 0.93), (0.91, 0.91), (0.90, 0.90), (0.91, 0.91) and (0.97, 0.96), respectively. Compared to ResNet-18D, ResNet-10t was more focused on the distribution of the heat map of the interest region for most chest radiographs from ASD patients. CONCLUSION: The ResNets model is feasible for identifying ASD through children's chest radiographs. ResNet-10t stands out as the preferable estimation model, providing exceptional performance and clear interpretability.


Assuntos
Ecocardiografia , Comunicação Interatrial , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Comunicação Interatrial/diagnóstico por imagem , Aprendizado de Máquina , Radiografia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA