Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39018213

RESUMO

Prosthetic hands have significant potential to restore the manipulative capabilities and self-confidence of amputees and enhance their quality of life. However, incompatibility between prosthetic devices and residual limbs can lead to secondary injuries such as skin pressure ulcers and restricted joint motion, contributing to a high prosthesis abandonment rate. To address these challenges, this study introduces a data-driven design framework (D3Frame) utilizing a multi-index optimization method. By incorporating motion/ pressure data, as well as clinical criteria such as pain threshold/ tolerance, from various anatomical sites on the residual limbs of amputees, this framework aims to optimize the structural design of the prosthetic socket, including the Antecubital Channel (AC), Lateral Epicondylar Region Contour (LC), Medial Epicondylar Region Contour (MC), Olecranon Region Contour (OC), Lateral Flexor/ Extensor Region (LR), and Medial Flexor/ Extensor Region (MR). Experiments on five forearm amputees verified the improved adaptability of the optimized socket compared to traditional sockets under three load conditions. The experimental results revealed a modest score enhancement on standard clinical scales and reduced muscle fatigue levels. Specifically, the percent effort of muscles and slope value of mean/ median frequency decreased by 19%, 70%, and 99% on average, respectively, and the average values of mean/ median frequency in the motion cycle both increased by approximately 5%. The proposed D3Frame in this study was applied to optimize the structural aspects of designated regions of the prosthetic socket, offering the potential to aid prosthetists in prosthesis design and, consequently, augmenting the adaptability of prosthetic devices.


Assuntos
Amputados , Membros Artificiais , Mãos , Desenho de Prótese , Humanos , Amputados/reabilitação , Masculino , Adulto , Algoritmos , Pessoa de Meia-Idade , Cotos de Amputação/fisiopatologia , Feminino
2.
Sensors (Basel) ; 24(14)2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39066140

RESUMO

BACKGROUND: The company Ethnocare has developed the Overlay, a new pneumatic solution for managing volumetric variations (VVs) of the residual limb (RL) in transtibial amputees (TTAs), which improves socket fitting. However, the impact of the Overlay during functional tasks and on the comfort and pain felt in the RL is unknown. METHODS: 8 TTAs participated in two evaluations, separated by two weeks. We measured compensatory strategies (CS) using spatio-temporal parameters and three-dimensional lower limb kinematics and kinetics during gait and sit-to-stand (STS) tasks. During each visit, the participant carried out our protocol while wearing the Overlay and prosthetic folds (PFs), the most common solution to VV. Between each task, comfort and pain felt were assessed using visual analog scales. RESULTS: While walking, the cadence with the Overlay was 105 steps/min, while it was 101 steps/min with PFs (p = 0.021). During 35% and 55% of the STS cycle, less hip flexion was observed while wearing the Overlay compared to PFs (p = 0.004). We found asymmetry coefficients of 13.9% with the Overlay and 17% with PFs during the STS (p = 0.016) task. Pain (p = 0.031), comfort (p = 0.017), and satisfaction (p = 0.041) were better with the Overlay during the second visit. CONCLUSION: The Overlay's impact is similar to PFs' but provides less pain and better comfort.


Assuntos
Cotos de Amputação , Amputados , Membros Artificiais , Extremidade Inferior , Desenho de Prótese , Ajuste de Prótese , Tíbia , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Amputação Cirúrgica , Cotos de Amputação/fisiopatologia , Extremidade Inferior/fisiopatologia , Tíbia/cirurgia , Fenômenos Biomecânicos , Dor/etiologia , Postura Sentada , Posição Ortostática , Marcha , Ajuste de Prótese/efeitos adversos , Membros Artificiais/efeitos adversos
3.
Sci Rep ; 14(1): 9725, 2024 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-38678076

RESUMO

Transtibial prosthetic users do often struggle to achieve an optimal prosthetic fit, leading to residual limb pain and stump-socket instability. Prosthetists face challenges in objectively assessing the impact of prosthetic adjustments on residual limb loading. Understanding the mechanical behaviour of the pseudo-joint formed by the residual bone and prosthesis may facilitate prosthetic adjustments and achieving optimal fit. This study aimed to assess the feasibility of using B-mode ultrasound to monitor in vivo residual bone movement within a transtibial prosthetic socket during different stepping tasks. Five transtibial prosthesis users participated, and ultrasound images were captured using a Samsung HM70A system during five dynamic conditions. Bone movement relative to the socket was quantified by tracking the bone contour using Adobe After-Effect. During the study a methodological adjustment was made to improve data quality, and the first two participants were excluded from analysis. The remaining three participants exhibited consistent range of motion, with a signal to noise ratio ranging from 1.12 to 2.59. Medial-lateral and anterior-posterior absolute range of motion varied between 0.03 to 0.88 cm and 0.14 to 0.87 cm, respectively. This study demonstrated that it is feasible to use B-mode ultrasound to monitor in vivo residual bone movement inside an intact prosthetic socket during stepping tasks.


Assuntos
Membros Artificiais , Tíbia , Ultrassonografia , Humanos , Masculino , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Tíbia/fisiologia , Ultrassonografia/métodos , Pessoa de Meia-Idade , Feminino , Adulto , Amplitude de Movimento Articular , Idoso , Cotos de Amputação/fisiopatologia , Cotos de Amputação/diagnóstico por imagem , Movimento/fisiologia , Desenho de Prótese , Amputados
4.
JMIR Res Protoc ; 13: e57329, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38669065

RESUMO

BACKGROUND: Relative motion between the residual limb and socket in individuals with transtibial limb loss can lead to substantial consequences that limit mobility. Although assessments of the relative motion between the residual limb and socket have been performed, there remains a substantial gap in understanding the complex mechanics of the residual limb-socket interface during dynamic activities that limits the ability to improve socket design. However, dynamic stereo x-ray (DSX) is an advanced imaging technology that can quantify 3D bone movement and skin deformation inside a socket during dynamic activities. OBJECTIVE: This study aims to develop analytical tools using DSX to quantify the dynamic, in vivo kinematics between the residual limb and socket and the mechanism of residual tissue deformation. METHODS: A lower limb cadaver study will first be performed to optimize the placement of an array of radiopaque beads and markers on the socket, liner, and skin to simultaneously assess dynamic tibial movement and residual tissue and liner deformation. Five cadaver limbs will be used in an iterative process to develop an optimal marker setup. Stance phase gait will be simulated during each session to induce bone movement and skin and liner deformation. The number, shape, size, and placement of each marker will be evaluated after each session to refine the marker set. Once an optimal marker setup is identified, 21 participants with transtibial limb loss will be fitted with a socket capable of being suspended via both elevated vacuum and traditional suction. Participants will undergo a 4-week acclimation period and then be tested in the DSX system to track tibial, skin, and liner motion under both suspension techniques during 3 activities: treadmill walking at a self-selected speed, at a walking speed 10% faster, and during a step-down movement. The performance of the 2 suspension techniques will be evaluated by quantifying the 3D bone movement of the residual tibia with respect to the socket and quantifying liner and skin deformation at the socket-residuum interface. RESULTS: This study was funded in October 2021. Cadaver testing began in January 2023. Enrollment began in February 2024. Data collection is expected to conclude in December 2025. The initial dissemination of results is expected in November 2026. CONCLUSIONS: The successful completion of this study will help develop analytical methods for the accurate assessment of residual limb-socket motion. The results will significantly advance the understanding of the complex biomechanical interactions between the residual limb and the socket, which can aid in evidence-based clinical practice and socket prescription guidelines. This critical foundational information can aid in the development of future socket technology that has the potential to reduce secondary comorbidities that result from complications of poor prosthesis load transmission. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/57329.


Assuntos
Extremidade Inferior , Pele , Tíbia , Humanos , Cotos de Amputação/diagnóstico por imagem , Cotos de Amputação/fisiopatologia , Membros Artificiais , Fenômenos Biomecânicos/fisiologia , Cadáver , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/cirurgia , Extremidade Inferior/fisiologia , Movimento/fisiologia , Pele/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
5.
Bol. Hosp. San Juan de Dios ; 39(5): 284-7, sept.-oct. 1992. ilus
Artigo em Espanhol | LILACS | ID: lil-119909

RESUMO

La amputación de muslo es el último recurso terapéutico del cirujano en el tratamiento de la insuficiencia arterial crónica de las extremidades inferiores. Es una operación frecuente (0,6% de las operaciones en nuestro Servicio) con una letalidad de 10%. En el presente artículo se establecen las indicaciones y las condiciones necesarias para decidir amputar a nivel del muslo, y se esquematiza una técnica quirúrgica sencilla y eficaz


Assuntos
Humanos , Amputação Cirúrgica/métodos , Arteriopatias Oclusivas/cirurgia , Doenças Vasculares Periféricas/cirurgia , Isquemia/cirurgia , Coxa da Perna/cirurgia , Amputação Cirúrgica/reabilitação , Cotos de Amputação/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA