Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 452
Filtrar
1.
BMC Ophthalmol ; 24(1): 206, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38711059

RESUMO

PURPOSE: The main objective is to quantify the lens nuclear opacity using spectral-domain optical coherence tomography (SD-OCT) and to evaluate its association with Lens Opacities Classification System III (LOCS-III) system, lens thickness (LT), and surgical parameters. The secondary objective is to assess the diagnostic model performance for hard nuclear cataract. METHODS: This study included 70 eyes of 57 adults with cataract, with 49 (70%) and 21 (30%) in training and validation cohort, respectively. Correlations of the average nuclear density (AND) /maximum nuclear density (MND) with LOCS-III scores, LT, and surgical parameters were analyzed. Univariate and multivariate logistic regression analysis, receiver operating characteristic curves and calibration curves were performed for the diagnostic of hard nuclear cataract. RESULTS: The pre-operative uncorrected distance visual acuity (UDVA), intraocular pressure (IOP), mean axial length (AL), and LT were 1.20 ± 0.47 log MAR, 15.50 ± 2.87 mmHg, 27.34 ± 3.77 mm and 4.32 ± 0.45 mm, respectively. The average nuclear opalescence (NO) and nuclear colour (NC) scores were 3.61 ± 0.94 and 3.50 ± 0.91 (ranging from 1.00 to 6.90), respectively. The average AND and MND were 137.94 ± 17.01 and 230.01 ± 8.91, respectively. NC and NO scores both significantly correlated with the AND (rNC = 0.733, p = 0.000; rNO = 0.755, p = 0.000) and MND (rNC = 0.643, p = 0.000; rNO = 0.634, p = 0.000). In the training cohort, the area under the curve (AUC) of the model was 0.769 (P < 0.001, 95%CI 0.620-0.919), which had a good degree of differentiation (Fig. 2a). The calibration curve showed good agreement between predicted and actual probability. CONCLUSION: The nuclear density measurement on SD-OCT images can serve as an objective and reliable indicator for quantifying nuclear density.


Assuntos
Catarata , Núcleo do Cristalino , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Feminino , Masculino , Tomografia de Coerência Óptica/métodos , Catarata/diagnóstico , Idoso , Pessoa de Meia-Idade , Núcleo do Cristalino/patologia , Núcleo do Cristalino/diagnóstico por imagem , Acuidade Visual/fisiologia , Curva ROC , Estudos Retrospectivos , Facoemulsificação , Idoso de 80 Anos ou mais , Adulto , Cristalino/diagnóstico por imagem , Cristalino/patologia
2.
BMJ Open Ophthalmol ; 9(1)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38684375

RESUMO

BACKGROUND: Retinal imaging, including fundus autofluorescence (FAF), strongly depends on the clearness of the optical media. Lens status is crucial since the ageing lens has both light-blocking and autofluorescence (AF) properties that distort image analysis. Here, we report both lens opacification and AF metrics and the effect on automated image quality assessment. METHODS: 227 subjects (range: 19-89 years old) received quantitative AF of the lens (LQAF), Scheimpflug, anterior chamber optical coherence tomography as well as blue/green FAF (BAF/GAF), and infrared (IR) imaging. LQAF values, the Pentacam Nucleus Staging score and the relative lens reflectivity were extracted to estimate lens opacification. Mean opinion scores of FAF and IR image quality were compiled by medical readers. A regression model for predicting image quality was developed using a convolutional neural network (CNN). Correlation analysis was conducted to assess the association of lens scores, with retinal image quality derived from human or CNN annotations. RESULTS: Retinal image quality was generally high across all imaging modalities (IR (8.25±1.99) >GAF >BAF (6.6±3.13)). CNN image quality prediction was excellent (average mean absolute error (MAE) 0.9). Predictions were comparable to human grading. Overall, LQAF showed the highest correlation with image quality grading criteria for all imaging modalities (eg, Pearson correlation±CI -0.35 (-0.50 to 0.18) for BAF/LQAF). BAF image quality was most vulnerable to an increase in lenticular metrics, while IR (-0.19 (-0.38 to 0.01)) demonstrated the highest resilience. CONCLUSION: The use of CNN-based retinal image quality assessment achieved excellent results. The study highlights the vulnerability of BAF to lenticular remodelling. These results can aid in the development of cut-off values for clinical studies, ensuring reliable data collection for the monitoring of retinal diseases.


Assuntos
Catarata , Tomografia de Coerência Óptica , Humanos , Idoso , Pessoa de Meia-Idade , Adulto , Idoso de 80 Anos ou mais , Feminino , Masculino , Tomografia de Coerência Óptica/métodos , Adulto Jovem , Catarata/diagnóstico por imagem , Catarata/patologia , Retina/diagnóstico por imagem , Retina/patologia , Imagem Óptica/métodos , Cristalino/diagnóstico por imagem , Cristalino/patologia , Angiofluoresceinografia/métodos
3.
Exp Eye Res ; 243: 109914, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38685338

RESUMO

A-scan ultrasonography enables precise measurement of internal ocular structures. Historically, its use has underpinned fundamental studies of eye development and aberrant eye growth in animal models of myopia; however, the procedure typically requires anaesthesia. Since anaesthesia affects intra-ocular pressure (IOP), we investigated changes in internal ocular structures with isoflurane exposure and compared measurements with those taken in awake animals using optical coherence tomography (OCT). Continuous A-scan ultrasonography was undertaken in tri-coloured guinea pigs aged 21 (n = 5), 90 (n = 5) or 160 (n = 5) days while anaesthetised (up to 36 min) with isoflurane (5% in 1.5L/min O2). Peaks were selected from ultrasound traces corresponding to the boundaries of the cornea, crystalline lens, retina, choroid and sclera. OCT scans (Zeiss Cirrus Photo 800) of the posterior eye layers were taken in 28-day-old animals (n = 19) and compared with ultrasound traces, with choroid and scleral thickness adjusted for the duration of anaesthesia based on the changes modelled in 21-day-old animals. Ultrasound traces recorded sequentially in left and right eyes in 14-day-old animals (n = 30) were compared, with each adjusted for anaesthesia duration. The thickness of the cornea was measured in enucleated eyes (n = 5) using OCT following the application of ultrasound gel (up to 20 min). Retinal thickness was the only ultrasound internal measure unaffected by anaesthesia. All other internal distances rapidly changed and were well fitted by exponential functions (either rise-to-max or decay). After 10 and 20 min of anaesthesia, the thickness of the cornea, crystalline lens and sclera increased by 17.1% and 23.3%, 0.4% and 0.6%, and 5.2% and 6.5% respectively, whilst the anterior chamber, vitreous chamber and choroid decreased by 4.4% and 6.1%, 0.7% and 1.1%, and 10.7% and 11.8% respectively. In enucleated eyes, prolonged contact of the cornea with ultrasound gel resulted in an increase in thickness of 9.3% after 10 min, accounting for approximately half of the expansion observed in live animals. At the back of the eye, ultrasound measurements of the thickness of the retina, choroid and sclera were highly correlated with those from posterior segment OCT images (R2 = 0.92, p = 1.2 × 10-13, R2 = 0.55, p = 4.0 × 10-4, R2 = 0.72, p = 5.0 × 10-6 respectively). Furthermore, ultrasound measures for all ocular components were highly correlated in left and right eyes measured sequentially, when each was adjusted for anaesthetic depth. This study shows that the depth of ocular components can change dramatically with anaesthesia. Researchers should therefore be wary of these concomitant effects and should employ adjustments to better render 'true' values.


Assuntos
Anestésicos Inalatórios , Isoflurano , Tomografia de Coerência Óptica , Ultrassonografia , Animais , Tomografia de Coerência Óptica/métodos , Cobaias , Isoflurano/farmacologia , Anestésicos Inalatórios/farmacologia , Corioide/efeitos dos fármacos , Corioide/diagnóstico por imagem , Envelhecimento/fisiologia , Pressão Intraocular/efeitos dos fármacos , Pressão Intraocular/fisiologia , Córnea/efeitos dos fármacos , Córnea/diagnóstico por imagem , Retina/efeitos dos fármacos , Retina/diagnóstico por imagem , Esclera/efeitos dos fármacos , Esclera/diagnóstico por imagem , Fatores de Tempo , Olho/diagnóstico por imagem , Olho/efeitos dos fármacos , Modelos Animais de Doenças , Cristalino/diagnóstico por imagem , Cristalino/efeitos dos fármacos
4.
Int Ophthalmol ; 44(1): 194, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656707

RESUMO

PURPOSE: To evaluate the magnitude of IOL transversal shift (ITS) after phacoemulsification and to analyse the factors contributing to IOL decentration and ITS. METHODS: 94 consecutive patients who underwent cataract surgery and IOL implantation was enrolled. Each patient underwent anterior segment optical coherence tomography with CASIA 2 (Tomey, Nagoya, Japan) to assess crystalline lens decentration, thickness and diameter seven days preoperatively and at one and sixty days postoperatively. Univariate and multivariate linear regression analysis were performed to evaluate the determinants of ITS and final decentration. RESULTS: The preoperative crystalline lens diameter was associated with the ITS and with the IOL final decentration. A positive association between the final IOL decentration and the first post-surgical day decentration was found (p < 0.0001). CONCLUSION: Greater crystalline lens diameter was associated with greater decentration and with greater ITS. Day-one IOL decentration seems to be the main determinant of final IOL decentration.


Assuntos
Segmento Anterior do Olho , Facoemulsificação , Tomografia de Coerência Óptica , Humanos , Facoemulsificação/efeitos adversos , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Idoso , Segmento Anterior do Olho/diagnóstico por imagem , Lentes Intraoculares/efeitos adversos , Pessoa de Meia-Idade , Acuidade Visual , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/etiologia , Implante de Lente Intraocular/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Cristalino/diagnóstico por imagem , Estudos Prospectivos
5.
BMC Ophthalmol ; 24(1): 203, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38684941

RESUMO

BACKGROUND: This study aims to investigate the morphologic features of the crystalline lens in Primary Angle Closure Disease (PACD) patients with zonular instability during cataract surgery using the swept-source CASIA 2 Anterior Segment-Optical Coherence Tomography (AS-OCT) system. METHODS: A total of 398 eyes (125 PACD eyes with zonular instability, 133 PACD eyes with zonular stability, and 140 cataract patient controls) of 398 patients who underwent cataract surgery combined or not glaucoma surgery between January 2021 and January 2023 were enrolled. The crystalline lens parameters were measured by CASIA2 AS-OCT. Then, logistic regression was performed to evaluate the risk factors associated with zonular instability. RESULTS: The results revealed that PACD eyes had a more anterior lens equator position, a steeper anterior curvature of lens, shorter Axial Length (AL), shallower Anterior Chamber Distance (ACD), higher Lens Vault (LV) and thicker Lens Thickness (LT), when compared to eyes in the cataract control group. Furthermore, PACD eyes in the zonular instability group had steeper front R, front Rs and Front Rf, flatter back Rf, thicker lens anterior part thickness, higher lens anterior-to-posterior part thickness ratios, shallower ACD, and greater LV, when compared to PACD eyes with zonular stability. The logistic regression analysis, which was adjusted for age and gender, revealed that zonular instability was positively correlated with anterior part thickness, lens anterior-to-posterior part thickness ratio, and LV, but was negatively correlated with lens anterior radius and ACD. CONCLUSION: Steeper anterior curvature, increased lens anterior part thickness, higher anterior-to-posterior part thickness ratio, shallower ACD, and greater LV are the anatomic features of PACD eyes associated with zonular instability.


Assuntos
Segmento Anterior do Olho , Glaucoma de Ângulo Fechado , Cristalino , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Glaucoma de Ângulo Fechado/fisiopatologia , Glaucoma de Ângulo Fechado/diagnóstico , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/patologia , Cristalino/diagnóstico por imagem , Cristalino/patologia , Estudos Retrospectivos , Pressão Intraocular/fisiologia , Acuidade Visual/fisiologia
6.
Vestn Oftalmol ; 140(1): 11-18, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38450461

RESUMO

Analysis of lens changes in Marfan syndrome (MS), in addition to assessing the position of the lens itself, should include the possibility of examining its supporting and accommodative components (ciliary zonule and ciliary body), or what can be called the entire anatomical complex of the lens. Optical methods of studying the structures of the anterior segment of the eye, due to iris opacity, allow only to analyze the state of the lens within the natural or medically enlarged pupil width. Visualization of the structures located behind the iris is possible with the use of radiation diagnostic methods, in particular ultrasound biomicroscopy (UBM). PURPOSE: This study assesses the state of the anatomical complex of the lens in MS using UBM. MATERIAL AND METHODS: The study was carried out on clinical material previously used by us to analyze changes in the fibrous membrane of the eye in MS. At the first stage, the main (19 patients with MS, 38 eyes) and the control (24 patients with myopia, 48 eyes) groups were formed for comparative evaluation. The formed groups were standardized according to the age of the patients and the axial length of the eye. At the second stage, patients with MS were divided into subgroups depending on the absence or presence of biomicroscopic signs of ectopia lentis (22 and 16 eyes, respectively). For UBM, an ultrasound linear sensor with a scanning frequency of 50 MHz was used (Aviso device, Quantel Medical, France). Various biometric UBM indicators were determined: lens thickness, diameter of the lens, lens-axial length factor, iris-lens angle, iris-lens contact distance, posterior chamber depth, length of the fibers of ciliary zonule, thickness of the ciliary body, sclera-ciliary process angle. RESULTS: There are changes in the anatomical complex of the lens as a whole in MS (in the lens itself, the ciliary zonule, and the ciliary body), which are characterized by an increase in lens thickness and a decrease in the diameter of the lens, an increase in the length of the fibers of the ciliary zonule and a decrease in the thickness of the ciliary body. At the same time, the displacement of the lens detected by optical biomicroscopy (ectopia lentis) can be considered as an advanced stage of changes in the anatomical complex of the lens. CONCLUSION: UBM provides the possibility of full-fledged visualization of all components of the anatomical complex of the lens in terms of both diagnostics, and monitoring of changes in MS. The question of the advisability of including this method in the algorithm for diagnosing ocular manifestations in order to verify the MS remains open. Possible obstacles may be, on the one hand, related to the need for special and expensive equipment, and on the other hand, the absence of a generally accepted «normal¼ values of UBM indicators of the anatomical complex of the lens.


Assuntos
Ectopia do Cristalino , Cristalino , Lentes , Síndrome de Marfan , Humanos , Ectopia do Cristalino/diagnóstico , Ectopia do Cristalino/etiologia , Síndrome de Marfan/complicações , Síndrome de Marfan/diagnóstico , Cristalino/diagnóstico por imagem , Iris
8.
Invest Ophthalmol Vis Sci ; 65(3): 13, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38466288

RESUMO

Purpose: Quantitative fundus autofluorescence (QAF) currently deploys an age-based score to correct for lens opacification. However, in elderly people, lens opacification varies strongly between individuals of similar age, and innate lens autofluorescence is not included in the current correction formula. Our goal was to develop and compare an individualized formula. Methods: One hundred thirty participants were examined cross-sectionally, and a subset of 30 participants received additional multimodal imaging 2-week post-cataract-surgery. Imaging included the Scheimpflug principle, anterior chamber optical coherence tomography (AC-OCT), lens quantitative autofluorescence (LQAF), and retinal QAF imaging. Among the subset, least absolute shrinkage and selection operator regression and backward selection was implemented to determine which lens score best predicts the QAF value after lens extraction. Subsequently, a spline mixed model was applied to the whole cohort to quantify the influence of LQAF and Scheimpflug on QAF. Results: Age and LQAF measurements were found to be the most relevant variables, whereas AC-OCT measurements and Scheimpflug were eliminated by backward selection. Both an increase in Scheimpflug and LQAF values were associated with a decrease in QAF. The prediction error of the spline model (mean absolute error [MAE] ± standard deviation) of 32.2 ± 23.4 (QAF a.u.) was markedly lower compared to the current age-based formula MAE of 96.1 ± 93.5. Both smooth terms, LQAF (P < 0.01) and Scheimpflug (P < 0.001), were significant for the spline mixed model. Conclusions: LQAF imaging proved to be the most predictive for the impact of the natural lens on QAF imaging. The application of lens scores in the clinic could improve the accuracy of QAF imaging interpretation and might allow including aged patients in future QAF studies.


Assuntos
Extração de Catarata , Catarata , Cristalino , Idoso , Humanos , Cristalino/diagnóstico por imagem , Fundo de Olho , Retina
9.
Curr Eye Res ; 49(6): 605-614, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38363071

RESUMO

PURPOSE: To investigate the influence of lens thickness (LT) on accuracy of Kane, Hill-RBF 3.0 Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO), and Pearl-DGS formulas in eyes with different axial lengths (AL). METHODS: The prospective cohort study was conducted at Eye and ENT Hospital of Fudan University. Patients who had uneventful cataract surgery between March 2021 and July 2023 were recruited. Manifest refraction was conducted two-month post-surgery. Eyes were divided into 4 groups based on AL: short (<22mm), medium (22-24.5 mm), medium long (24.5-26mm) and very long (≥26mm). In each AL group, eyes were then divided into 3 subgroups based on the LT measured with IOLmaster700: thin (<4.5 mm), medium (4.5-5.0 mm), and thick (≥ 5 mm). The influence of LT on accuracy of Kane, Hill-RBF 3.0, BUII, EVO, and Pearl-DGS formulas were investigated in each AL group. RESULTS: A total of 327 eyes from 327 patients were analyzed, with 64, 102, 73 and 88 eyes in each AL group, respectively. In eyes with AL < 24.5 mm, myopic PE was significantly associated with greater LT using all the 5 formulas (all p < 0.05). Backward stepwise multivariate regression analyses revealed that LT was an important influencing factor for PE in all 5 formulas, particularly in eyes with AL <24.5 mm. In eyes with AL <24.5 mm and LT > 5.0 mm, PE of all 5 formulas calculated with the optional parameter LT were more myopic than those calculated without LT. CONCLUSIONS: Thicker LT was associated with more myopic PE among eyes with AL <24.5 mm when using all 5 formulas. Further optimization of current formulas is necessary, especially for eyes with short AL and thick LT.


Assuntos
Comprimento Axial do Olho , Biometria , Emetropia , Cristalino , Miopia Degenerativa , Refração Ocular , Humanos , Estudos Prospectivos , Masculino , Feminino , Refração Ocular/fisiologia , Comprimento Axial do Olho/patologia , Emetropia/fisiologia , Biometria/métodos , Pessoa de Meia-Idade , Cristalino/patologia , Cristalino/diagnóstico por imagem , Idoso , Miopia Degenerativa/diagnóstico , Miopia Degenerativa/fisiopatologia , Acuidade Visual , Óptica e Fotônica , Lentes Intraoculares , Implante de Lente Intraocular , Reprodutibilidade dos Testes , Miopia/fisiopatologia , Miopia/diagnóstico
10.
Curr Eye Res ; 49(6): 671-681, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38379315

RESUMO

PURPOSE: Accommodation mainly affects the lens, a structure of the eyeball that degrades with age. The aim of this work was to study the morphological changes of different ocular structures during accommodation, both in the anterior pole and the posterior pole, which may also be involved in the accommodation process. METHODS: The study will be carried out by stimulating accommodation through lenses of -1.00, -3.00 and -5.00 D starting from the spherical equivalent (M) of each participant in different age groups, from 18 to 66 years. To obtain the M value, aberrometry was achieved, and retinal optical coherence tomography and anterior pole tomography were performed to evaluate the possible structural modifications (central and peripheral), while accommodation was progressively stimulated. RESULTS: It showed that as the accommodative demand increased, morphological changes were produced in retinal thickness, both in the central and peripheral retina, in all age groups. A thinning of the retina was observed in the central 3 mm, while significant progressive thickening was observed closer to the periphery (up to 6 mm from the fovea) as the required accommodative power increased. A decrease in the anterior chamber depth (ACD) and anterior chamber volume (ACV) was observed with increasing lens power. CONCLUSION: Structural changes were observed in the central and peripheral retina, as well as in the ACD and ACV, while progressively greater accommodation was stimulated, showing that these structures were modified in the accommodation process even in advanced presbyopes.


Assuntos
Acomodação Ocular , Envelhecimento , Câmara Anterior , Retina , Tomografia de Coerência Óptica , Humanos , Acomodação Ocular/fisiologia , Tomografia de Coerência Óptica/métodos , Adulto , Pessoa de Meia-Idade , Idoso , Adulto Jovem , Câmara Anterior/diagnóstico por imagem , Retina/diagnóstico por imagem , Masculino , Adolescente , Envelhecimento/fisiologia , Feminino , Cristalino/diagnóstico por imagem , Cristalino/fisiologia , Cristalino/anatomia & histologia , Refração Ocular/fisiologia
11.
Pediatr Radiol ; 54(5): 758-763, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38308740

RESUMO

BACKGROUND: Adaptive collimation reduces the dose deposited outside the imaged volume along the z-axis. An increase in the dose deposited outside the imaged volume (to the lens and thyroid) in the z-axis direction is a concern in paediatric computed tomography (CT). OBJECTIVE: To compare the dose deposited outside the imaged volume (to the lens and thyroid) between 40-mm and 80-mm collimation during thoracic paediatric helical CT. MATERIALS AND METHODS: We used anthropomorphic phantoms of newborns and 5-year-olds with 40-mm and 80-mm collimation during helical CT. We compared the measured dose deposited outside the imaged volume using optically stimulated luminescence dosimeters (OSLD) at the surfaces of the lens and thyroid and the image noise between the 40-mm and 80-mm collimations. RESULTS: There were significant differences in the dose deposited outside the imaged volume (to the lens and thyroid) between the 40-mm and 80-mm collimations for both phantoms (P < 0.01). CONCLUSION: Compared with that observed for 80-mm collimation in helical CT scans of the paediatric thorax, the dose deposited outside the imaged volume (to the lens and thyroid) was significantly lower in newborns and 5-year-olds with 40-mm collimation.


Assuntos
Cristalino , Imagens de Fantasmas , Doses de Radiação , Radiografia Torácica , Glândula Tireoide , Humanos , Glândula Tireoide/diagnóstico por imagem , Recém-Nascido , Cristalino/diagnóstico por imagem , Cristalino/efeitos da radiação , Radiografia Torácica/métodos , Radiografia Torácica/instrumentação , Pré-Escolar , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada Espiral/métodos
12.
Int Ophthalmol ; 44(1): 34, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38332205

RESUMO

PURPOSE: To explore the associations between central anterior chamber depth (CACD) and other anterior segment biometric parameters and to determine the possible determinants of CACD in short, normal, and long eyes. METHODS: The biometric data of pre-operation patients aged 50-80 years with coexisting cataract and primary angle-closure disease or senile cataract were reviewed. Axial length (AL), CACD, lens thickness (LT), central corneal thickness (CCT), and white-to-white distance (WTW) were measured by Lenstar optical biometry (Lenstar 900). The data of 100 normal eyes (AL = 22 to 26 mm), 100 short eyes (AL ≤ 22 mm), and 100 long eyes (AL ≥ 26 mm) were consecutively collected for subsequent analyses. RESULTS: The mean age of the subjects was 66.60 ± 7.85 years, with 25.7% of the sample being men. Both CACD and WTW were found to be smallest in short eyes and were smaller in normal eyes than in long eyes (F = 126.524, P < 0.001; F = 28.458, P < 0.001). The mean LT was significantly thicker in short eyes than in normal and long eyes (4.66 mm versus 4.49 mm versus 4.40 mm; F = 18.099, P < 0.001). No significant differences were observed in CCT between the three AL groups (F = 2.135, P = 0.120). Stepwise regression analysis highlighted AL, LT, and WTW as three independent factors associated with CACD in the normal AL group. In the short AL group and long AL group, LT and WTW were independent factors associated with CACD. CONCLUSIONS: CACD increases as AL elongates and reaches a peak when AL exceeds 26 mm. Furthermore, CACD showed inverse correlation with LT and positive correlation with WTW. A relatively small WTW results in an anteriorly positioned lens, and thus, a decrease in CACD.


Assuntos
Catarata , Cristalino , Lentes Intraoculares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Cristalino/diagnóstico por imagem , Catarata/complicações , Catarata/diagnóstico , Biometria/métodos , Câmara Anterior/diagnóstico por imagem , Comprimento Axial do Olho
13.
Eye (Lond) ; 38(7): 1333-1341, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38200321

RESUMO

BACKGROUND/OBJECTIVES: Axial length, a key measurement in myopia management, is not accessible in many settings. We aimed to develop and assess machine learning models to estimate the axial length of young myopic eyes. SUBJECTS/METHODS: Linear regression, symbolic regression, gradient boosting and multilayer perceptron models were developed using age, sex, cycloplegic spherical equivalent refraction (SER) and corneal curvature. Training data were from 8135 (28% myopic) children and adolescents from Ireland, Northern Ireland and China. Model performance was tested on an additional 300 myopic individuals using traditional metrics alongside the estimated axial length vs age relationship. Linear regression and receiver operator characteristics (ROC) curves were used for statistical analysis. The contribution of the effective crystalline lens power to error in axial length estimation was calculated to define the latter's physiological limits. RESULTS: Axial length estimation models were applicable across all testing regions (p ≥ 0.96 for training by testing region interaction). The linear regression model performed best based on agreement metrics (mean absolute error [MAE] = 0.31 mm, coefficient of repeatability = 0.79 mm) and a smooth, monotonic estimated axial length vs age relationship. This model was better at identifying high-risk eyes (axial length >98th centile) than SER alone (area under the curve 0.89 vs 0.79, respectively). Without knowing lens power, the calculated limits of axial length estimation were 0.30 mm for MAE and 0.75 mm for coefficient of repeatability. CONCLUSIONS: In myopic eyes, we demonstrated superior axial length estimation with a linear regression model utilising age, sex and refractive metrics and showed its clinical utility as a risk stratification tool.


Assuntos
Comprimento Axial do Olho , Miopia , Refração Ocular , Humanos , Miopia/fisiopatologia , Miopia/diagnóstico , Masculino , Feminino , Comprimento Axial do Olho/patologia , Comprimento Axial do Olho/diagnóstico por imagem , Adolescente , Criança , Refração Ocular/fisiologia , Curva ROC , Biometria/métodos , Adulto Jovem , Cristalino/fisiopatologia , Cristalino/diagnóstico por imagem , Cristalino/patologia , Modelos Lineares , Córnea/patologia , Córnea/diagnóstico por imagem , Córnea/fisiopatologia
14.
Radiat Prot Dosimetry ; 200(4): 417-422, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38195763

RESUMO

This case report investigates the radiation dose received by a paediatric patient with a ventricular assist device who underwent four non-contrast brain computed tomography (CT) scans, two brain perfusion CT scans and two head angiographic CT scans. The total estimated absorbed dose to the lens of the eye is above the 500 mGy radiation-induced cataract threshold. It is recommended that this patient and those with similar imaging histories have routine follow-up with an ophthalmologist. It is also recommended that radiation dose tracking and an electronic medical alert program be implemented to allow the identification of patients who may exceed tissue reaction thresholds.


Assuntos
Catarata , Cristalino , Humanos , Criança , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Catarata/diagnóstico por imagem , Catarata/etiologia , Cabeça , Cristalino/diagnóstico por imagem
15.
Br J Ophthalmol ; 108(4): 513-521, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-37495263

RESUMO

BACKGROUND: The crystalline lens is a transparent structure of the eye to focus light on the retina. It becomes muddy, hard and dense with increasing age, which makes the crystalline lens gradually lose its function. We aim to develop a nuclear age predictor to reflect the degeneration of the crystalline lens nucleus. METHODS: First we trained and internally validated the nuclear age predictor with a deep-learning algorithm, using 12 904 anterior segment optical coherence tomography (AS-OCT) images from four diverse Asian and American cohorts: Zhongshan Ophthalmic Center with Machine0 (ZOM0), Tomey Corporation (TOMEY), University of California San Francisco and the Chinese University of Hong Kong. External testing was done on three independent datasets: Tokyo University (TU), ZOM1 and Shenzhen People's Hospital (SPH). We also demonstrate the possibility of detecting nuclear cataracts (NCs) from the nuclear age gap. FINDINGS: In the internal validation dataset, the nuclear age could be predicted with a mean absolute error (MAE) of 2.570 years (95% CI 1.886 to 2.863). Across the three external testing datasets, the algorithm achieved MAEs of 4.261 years (95% CI 3.391 to 5.094) in TU, 3.920 years (95% CI 3.332 to 4.637) in ZOM1-NonCata and 4.380 years (95% CI 3.730 to 5.061) in SPH-NonCata. The MAEs for NC eyes were 8.490 years (95% CI 7.219 to 9.766) in ZOM1-NC and 9.998 years (95% CI 5.673 to 14.642) in SPH-NC. The nuclear age gap outperformed both ophthalmologists in detecting NCs, with areas under the receiver operating characteristic curves of 0.853 years (95% CI 0.787 to 0.917) in ZOM1 and 0.909 years (95% CI 0.828 to 0.978) in SPH. INTERPRETATION: The nuclear age predictor shows good performance, validating the feasibility of using AS-OCT images as an effective screening tool for nucleus degeneration. Our work also demonstrates the potential use of the nuclear age gap to detect NCs.


Assuntos
Catarata , Cristalino , Humanos , Pré-Escolar , Lactente , Cristalino/diagnóstico por imagem , Catarata/diagnóstico , Retina , Algoritmos , Tomografia de Coerência Óptica/métodos
16.
BMC Ophthalmol ; 23(1): 480, 2023 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-37993828

RESUMO

BACKGROUND: The spatial position of the lens in patients with cortical age-related cataract (CARC) is unclear. We investigated a basis for the assessment of visual quality after cataract surgery by analysing the ultrasound biomicroscopic characteristics of the biological parameters of the lens in patients with CARC. METHODS: In this retrospective study, 119 patients (50 males and 69 females, totalling 238 eyes) with CARC who underwent simple cataract surgery were selected. The lens thickness (LT), axial length (AL), anterior chamber depth (ACD), lens vault (LV), trabecular-iris angle (TIA), iris-lens angle (ILA), iris-lens contact distance (ILCD) were measured by A-scan ultrasound and ultrasound biomicroscopy. The corresponding lens position (LP) and relative lens position (RLP) were calculated. RESULTS: LP was greater in men than in women (P < 0.05), LV was smaller in men than in women (P = 0.002), ILA and ILCD were not statistically significant (P = 0.072 and P = 0.854, respectively). There were significant differences in TIA, ILA, and ILCD in the four quadrants (all P < 0.05), with a trend in the distribution of TIA: superior < inferior < nasal < temporal, ILA: nasal < inferior < temporal < superior, and ILCD: superior < temporal < inferior < nasal. CONCLUSIONS: The lens protrudes more obviously in females than in males and the lens tilts to a certain extent with the increase of age and tends to be more upward and temporal in the supine position. Therefore, trends in lens-related parameters in patients with CARC should be taken seriously.


Assuntos
Catarata , Glaucoma de Ângulo Fechado , Cristalino , Masculino , Humanos , Feminino , Microscopia Acústica , Estudos Retrospectivos , Cristalino/diagnóstico por imagem , Câmara Anterior/diagnóstico por imagem , Iris/diagnóstico por imagem
17.
Optom Vis Sci ; 100(12): 823-832, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37890121

RESUMO

SIGNIFICANCE: This study provides a new method to measure the refractive index of crystalline lens in the human eye in vivo . PURPOSE: Accessing the refractive index of crystalline lenses in the human eye in vivo has long been a challenge. This study aimed to measure the refractive index of a lens in vivo using an anterior segment optical coherence tomography (AS-OCT) system combined with a Scheimpflug imaging system. METHOD: A ray-traceable Scheimpflug imaging was developed and integrated into an AS-OCT system. A theoretical study revealed that the combination of these two systems provides a unique solution for simultaneously measuring the refractive index and the thickness of the lens. The average lens refractive index along the ray pathway ( Nav ) and lens shape were measured for seven subjects. RESULTS: The lens Nav along the central ray varies from 1.383 to 1.419 between subjects. The lens refractive index function across the lens diameter varies from subject to subject. The lens Nav increases for accommodated eyes. The thicknesses and profiles of the lenses are also determined. CONCLUSIONS: The lens refractive index varies substantially from individual eye to individual eye, not only along the central ray pathway but also for the lens refractive index function across the lens diameter. Ray-traceable Scheimpflug imaging-equipped AS-OCT is useful for testing the refractive index of lenses in the human eye in vivo .


Assuntos
Cristalino , Lentes , Humanos , Refratometria , Refração Ocular , Cristalino/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos
18.
Jpn J Ophthalmol ; 67(6): 678-684, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37596442

RESUMO

PURPOSE: To compare the differences in anterior segment parameters between eyes with primary angle closure (PAC) with and without gonioscopically-visualized ciliary body processes (CBP). STUDY DESIGN: Prospective, observational, comparative clinical study. METHODS: Detailed ocular examinations and gonioscopy were performed in 89 eyes of 89 patients with PAC to determine the visibility of the CBP. Anterior chamber depth (ACD), anterior chamber width, lens thickness (LT), lens vault (LV) and pupil diameter were determined using ultrasound biomicroscopy. The lens-axial length factor (LAF) and relative lens position (RLP) were calculated. All parameters were compared between eyes with and without gonioscopically visible CBP (PAC+CBP and PAC-CBP groups) after adjusting for age and gender. The association of the parameters with visible CBP was analyzed by univariate logistic regression analysis. RESULTS: PAC+CBP group included 41 eyes and the PAC-CBP group, 48 eyes. The axial length and ACD were statistically significantly smaller (p = 0.009 and p = 0.005, respectively) and LT, LV and LAF were statistically significantly greater (p = 0.03, p = 0.008 and p = 0.004, respectively) in the PAC+CBP group. In the PAC eyes with glaucoma, the LT, LV and LAF were statistically significantly greater in the PAC+CBP group (p = 0.02, p = 0.001 and p = 0.02, respectively). The LAF had the strongest association with visible CBP in the regression analysis (Odds ratio = 141.70, p = 0.002). CONCLUSION: Gonioscopical visualization of ciliary processes may suggest that anterior segment crowding, especially lens factor is the underlying mechanism in PAC. It may provide a practical gonioscopic examination method for predicting the predominant pathophysiology of PAC.


Assuntos
Glaucoma de Ângulo Fechado , Cristalino , Humanos , Corpo Ciliar/diagnóstico por imagem , Estudos Prospectivos , Pressão Intraocular , Glaucoma de Ângulo Fechado/diagnóstico , Cristalino/diagnóstico por imagem , Gonioscopia , Segmento Anterior do Olho , Biometria , Tomografia de Coerência Óptica/métodos
19.
J Cataract Refract Surg ; 49(11): 1133-1139, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37586102

RESUMO

PURPOSE: To investigate the ciliary body anatomy and position of the implantable collamer lens (ICL) in low-vault eyes and analyze factors related to insufficient vault. SETTING: Zhongshan Ophthalmic Center, Guangzhou, China. DESIGN: Retrospective case-control observational study. METHODS: In this study, 73 eyes of 73 patients with an insufficient vault (<250 µm) were matched with 73 eyes with an ideal vault (250 to 750 µm). Ultrasound biomicroscopy was used to determine the ciliary body morphology and ICL position. The biometric parameters acquired by Scheimpflug tomography were compared. The correlation between the vault and these factors was analyzed, and the least absolute shrinkage and selection operator method was used to screen the risk factors for low vault. RESULTS: The low-vault group had a steeper corneal curvature, thicker lens thickness (LT), higher crystalline lens rise, and shorter axial length (AL) (all P < .005). The ciliary process length (CPL) and maximum ciliary body thickness (CBTmax) were significantly smaller, and the trabecular-ciliary angle (TCA), iris-ciliary angle (ICA), and ciliary sulcus width (CSW) were significantly greater in the low-vault eyes (all P < .005). The low-vault group had more ICL haptics below the ciliary process, and TCA, ICA, CPL, CBTmax, CSW, and haptic position were related to the postoperative vault (all P < .05). CPL, AL, and LT were identified as predictors of a low vault. CONCLUSIONS: Malposition of ICL haptics behind the ciliary process is a risk factor for low vault. A shorter CPL, thicker LT, and shorter AL are significant risk factors for the postoperative low vault.


Assuntos
Cristalino , Lentes Intraoculares , Lentes Intraoculares Fácicas , Humanos , Corpo Ciliar/diagnóstico por imagem , Corpo Ciliar/cirurgia , Estudos Retrospectivos , Microscopia Acústica/métodos , Cristalino/diagnóstico por imagem
20.
Invest Ophthalmol Vis Sci ; 64(11): 31, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37639248

RESUMO

Purpose: The mechanical properties of the crystalline lens are related to its optical function of accommodation, and their changes with age are one of the potential causes for presbyopia. We estimated the mechanical parameters of the crystalline lens using quantitative optical coherence tomography (OCT) imaging and wavefront sensing data from accommodating participants and computer modeling. Methods: Full-lens shape data (from quantitative swept-source OCT and eigenlens representation) and optical power data (from Hartmann-Shack wavefront sensor) were obtained from 11 participants (22-30 years old) for relaxed accommodation at infinity and -4.5 D accommodative demand. Finite element models of lens, capsular bag, zonulae, and ciliary body were constructed using measured lens geometry and literature data, assuming a 60-mN radial force. An inverse modeling scheme was used to determine the shear moduli of the nucleus and cortex of the lens, such that the simulated deformed (maximally stretched) lens matched the participant's lens at -4.5 D. Results: The shear moduli of the nucleus and cortex were 1.62 ± 1.32 and 8.18 ± 5.63 kPa, on average, respectively. The shear modulus of the nucleus was lower than that of the cortex for all participants evaluated. The average of the two moduli per participant was statistically significantly correlated with age (R2 = 0.76, P = 0.0049). Conclusions: In vivo imaging and mechanical modeling of the crystalline lens allow estimations of the crystalline lens' mechanical properties. Differences between nuclear and cortical moduli and their dependency with age appear to be critical in accommodative function and likely in its impairment in presbyopia.


Assuntos
Acomodação Ocular , Cristalino , Tomografia de Coerência Óptica , Humanos , Masculino , Feminino , Cristalino/diagnóstico por imagem , Análise de Elementos Finitos , Presbiopia , Tomografia de Coerência Óptica/métodos , Simulação por Computador , Voluntários Saudáveis , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA