Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47.923
Filtrar
1.
J Agric Food Chem ; 72(19): 11051-11061, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38698723

RESUMO

Multiple analytical methodologies allow quantitation of H2S and methanethiol (MeSH) in wine, but confirmation that the determined concentrations are related to perceived off-aromas, or "reductive" faults, is yet to be provided. Fifty white wines underwent sensory evaluation and measurement of free and salt-treated H2S and MeSH concentrations by gas chromatography with sulfur chemiluminescence detection and/or gas detection tubes. The determined concentrations were compared across techniques and different analysis laboratories. Sulfhydryl off-odors in the wines were best described by boiled and rotten egg and natural gas/sewerage/durian aroma attributes. The wines with the highest ratings for both aromas had high concentrations of free H2S, free MeSH, and/or salt-treated MeSH but were unrelated to salt-treated H2S. The free sulfhydryl concentrations and their associated aromas appeared to be suppressed by specific Cu fractions in the wines. This study provides evidence of the relevant measures of reductive aroma compounds and their relation to off-odors and Cu fractions.


Assuntos
Cobre , Odorantes , Compostos de Sulfidrila , Vinho , Vinho/análise , Odorantes/análise , Compostos de Sulfidrila/análise , Humanos , Cobre/análise , Cromatografia Gasosa/métodos , Paladar , Sulfeto de Hidrogênio/análise , Feminino , Masculino , Adulto , Oxirredução , Pessoa de Meia-Idade , Olfato , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/química
2.
Se Pu ; 42(5): 481-486, 2024 Apr 08.
Artigo em Chinês | MEDLINE | ID: mdl-38736392

RESUMO

Ibandronate sodium, a third-generation diphosphate drug used worldwide to treat osteoporosis, has the advantages of convenient use, low toxicity, and significant therapeutic effects. However, the residual organic solvents in the synthesis process of sodium ibandronate not only have a negative impact on the efficacy of the drug, but also lead to a decrease in drug stability. Moreover, if the residual amounts of these solvents exceed safety standards, they may pose serious threats to human health. This study successfully established a convenient and efficient method based on headspace-gas chromatography (HS-GC) for the simultaneous determination of five residual solvents (methanol, acetone, benzene, toluene, 1-pentanol) in the raw materials of ibandronate sodium. The results indicated that satisfactory analytical performance can be achieved by using DB-624 capillary column (30 m×0.32 mm×1.8 µm) and a flame ionization detector in conjunction with headspace autosampling and a temperature program. The specific operating conditions included an initial temperature of 40 ℃, with a hold of 2 min, followed by a temperature ramp first to 200 ℃ at a rate of 5 ℃/min and then to 240 ℃ at a rate of 20 ℃/min, with a hold of 5 min. Nitrogen with a flow rate of 1 mL/min and split ratio of 14∶1 was used as the carrier gas. The headspace vial temperature was maintained at 80 ℃, and the sample equilibration time was 20 min. Under the established analytical conditions, good linear relationships were obtained between the mass concentrations of methanol (72-216 µg/mL), acetone (120-360 µg/mL), benzene (0.048-0.144 µg/mL), toluene (21.36-64.08 µg/mL), and 1-pentanol (120-360 µg/mL) and their corresponding peak areas, with correlation coefficients (r) greater than 0.990. The limits of detection for these solvents were 2.88, 0.011, 0.90, 0.24, and 0.024 ng/mL, respectively, with limits of quantification of 11.5, 0.043, 3.6, 0.96, and 0.096 ng/mL, respectively. Furthermore, the recoveries of these solvents ranged from 86.3% to 101.9%, with relative standard deviations (RSDs, n=3) of less than 2.49%. The proposed method is simple, accurate, reliable, and suitable for the rapid and simultaneous determination of five residual solvents in the raw materials of ibandronate sodium. This study has important practical significance in improving drug safety and ensuring public health.


Assuntos
Ácido Ibandrônico , Solventes , Cromatografia Gasosa/métodos , Solventes/química , Ácido Ibandrônico/análise , Difosfonatos/análise , Contaminação de Medicamentos
3.
Chirality ; 36(5): e23676, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38736271

RESUMO

Among different substance classes, New Psychoactive Substances (NPS) comprise chiral amphetamines for stimulant and empathic effects. There is little knowledge in terms of clinical studies about possibly different effects of the two enantiomers of novel amphetamine derivatives. For this reason, there is a big demand for enantioseparation method development of this new substance class. Regarding gas chromatography, cyclodextrins proved to be effective for enantioseparation of NPS. In our attempt, an Astec® Chiraldex™ G-PN column containing 2,6-di-O-pentyl-3-propionyl-γ-cyclodextrin and a Lipodex™ D column containing heptakis-(2,6-di-O-pentyl-O-acetyl)-ß-cyclodextrin as chiral selector served as stationary phases in a Shimadzu GCMS-QP2010 SE system. Because of the special coating, maximum temperature is limited to 200 °C isothermal or 220 °C in programmed mode. To ensure detection, trifluoroacetic anhydride (TFAA) was used to increase sample volatility.1 As a result, 35 amphetamines were tested as their TFAA-derivatives. A screening method with a temperature gradient from 140 °C to 200 °C at a heating ramp of 1 °C per minute and final time of 5 min, showed baseline separation for seven and partial separations for 16 trifluoro acetylated amphetamines using the Chiraldex™ G-PN column. Six baseline and nine partial separations were observed with the Lipodex™ D column, respectively.


Assuntos
Anfetaminas , Estereoisomerismo , Anfetaminas/química , Anfetaminas/isolamento & purificação , Cromatografia Gasosa/métodos , Ciclodextrinas/química , Temperatura , Cromatografia Gasosa-Espectrometria de Massas/métodos
4.
J Chromatogr A ; 1726: 464961, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38723491

RESUMO

The improvement of the stability and adsorption properties of materials on targets in sample pre-treatment has long been an objective. Extensive efforts have been made to achieve this goal. In this work, metal-organic framework Ni-MOF precursors were first synthesized by solvothermal method using polyvinylpyrrolidone (PVP) as an ideal templating agent, stabiliser and nanoparticle dispersant. After carbonization and acid washing, the nanoporous carbon microspheres material (Ni@C-acid) was obtained. Compared with the material without acid treatment (Ni@C), the specific surface area, pore volume, adsorption performance of Ni@C-acid were increased. Thanks to its excellent characteristics (high stability, abundant benzene rings), Ni@C-acid was used as fiber coatings in headspace solid-phase microextraction (HS-SPME) technology for extraction and preconcentration of polycyclic aromatic hydrocarbons (PAHs) prior to gas chromatography-flame ionization detector (GC-FID) analysis. The experimental parameters of extraction temperature, extraction time, agitation speed, desorption temperature, desorption time and sodium chloride (NaCl) concentration were studied. Under optimal experimental conditions, the wide linear range (0.01-30 ng mL-1), the good correlation coefficient (0.9916-0.9984), the low detection limit (0.003-0.011 ng mL-1), and the high enrichment factor (5273-13793) were obtained. The established method was successfully used for the detection of trace PAHs in actual tea infusions samples and satisfied recoveries ranging from 80.94-118.62 % were achieved. The present work provides a simple method for the preparation of highly stable and adsorbable porous carbon microsphere materials with potential applications in the extraction of environmental pollutants.


Assuntos
Carbono , Limite de Detecção , Estruturas Metalorgânicas , Microesferas , Hidrocarbonetos Policíclicos Aromáticos , Microextração em Fase Sólida , Chá , Microextração em Fase Sólida/métodos , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/análise , Chá/química , Carbono/química , Estruturas Metalorgânicas/química , Porosidade , Adsorção , Níquel/química , Níquel/isolamento & purificação , Cromatografia Gasosa/métodos , Reprodutibilidade dos Testes
5.
J Chromatogr A ; 1726: 464946, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38744185

RESUMO

On-line coupled high performance liquid chromatography-gas chromatography-flame ionisation detection (HPLC-GC-FID) was used to compare the effect of hydrogen, helium and nitrogen as carrier gases on the chromatographic characteristics for the quantification of mineral oil hydrocarbon (MOH) traces in food related matrices. After optimisation of chromatographic parameters nitrogen carrier gas exhibited characteristics equivalent to hydrogen and helium regarding requirements set by current guidelines and standardisation such as linear range, quantification limit and carry over. Though nitrogen expectedly led to greater peak widths, all required separations of standard compounds were sufficient and humps of saturated mineral oil hydrocarbons (MOSH) and aromatic mineral oil hydrocarbons (MOAH) were appropriate to enable quantitation similar to situations where hydrogen or helium had been used. Slightly increased peak widths of individual hump components did not affect shapes and widths of the MOSH and MOAH humps were not significantly affected by the use of nitrogen as carrier gas. Notably, nitrogen carrier gas led to less solvent peak tailing and smaller baseline offset. Overall, nitrogen may be regarded as viable alternative to hydrogen or helium and may even extend the range of quantifiable compounds to highly volatile hydrocarbon eluting directly after the solvent peak.


Assuntos
Hidrocarbonetos , Óleo Mineral , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Gasosa/métodos , Óleo Mineral/química , Óleo Mineral/análise , Hidrocarbonetos/análise , Nitrogênio/análise , Hélio/química , Hidrogênio/química , Ionização de Chama/métodos , Gases/química
6.
Head Face Med ; 20(1): 32, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750491

RESUMO

BACKGROUND: Chronic kidney disease (CKD) directly affects oral health. Yet data about halitosis in young CKD patients and the impact of dental prophylaxis is limited. Therefore, as part of this randomized clinical trial, halitosis in young CKD patients undergoing intensive or standard oral preventive procedures was to be explored. METHODS: Three volatile sulfur compounds (hydrogen sulfide, methyl mercaptan and dimethyl sulfide) were measured in 30 young patients with CKD (mean age 14.2 years; 16 males, 14 females). Breath samples were taken after 3 and 6 months and analyzed with selective gas chromatography (OralChroma). Tongue coating (Winkel Index) and clinical indices to determine local inflammation or oral hygiene (Papillary Bleeding Index and Quigley-Hein Index) were assessed. Within an extended anamnesis, patients and their mothers and nurses were questioned about the perceived halitosis. Corresponding quotes were noted verbatim. Patients were randomized to either intensive need-related oral health care measures (oral preventative program, OPP) or a one-stage standard prevention (treatment as usual, TAU). RESULTS: While there were no differences in volatile sulfur compound levels between TAU and OPP at the three time points of measurements (p > 0.05), there was a tendency towards a reduction in dimethyl sulfide and hydrogen sulfide of affected patients within the OPP group over time. Looking at potential differences between both groups with regard to tongue coating, significant differences were observed between baseline and 3 months after study start in the OPP group, and between baseline and 6 months after study start in the TAU group (p < 0.05). The burden of halitosis was frequently reported by patients' mothers and nurses. CONCLUSIONS: Young CKD patients regularly suffered from halitosis and dimethyl sulfide was its main source. Preventive measures mainly resulted in a reduction of tongue coating. TRIAL REGISTRATION: The German Clinical Trial Register (# DRKS00010580).


Assuntos
Halitose , Insuficiência Renal Crônica , Humanos , Halitose/etiologia , Halitose/prevenção & controle , Feminino , Masculino , Adolescente , Insuficiência Renal Crônica/complicações , Testes Respiratórios/métodos , Criança , Higiene Bucal , Compostos de Enxofre/análise , Cromatografia Gasosa/métodos , Sulfeto de Hidrogênio
7.
J Chromatogr A ; 1725: 464949, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38688054

RESUMO

This study introduces an innovative needle trap device (NTD) featuring a molecularly imprinted polymer (MIP) surface-modified Zeolite Y. The developed NTD was integrated with gas chromatography-flame ionization detector (GC-FID) and employed for analysis of fuel ether oxygenates (methyl tert­butyl ether, MTBE, ethyl tert­butyl ether, ETBE, and tert­butyl formate, TBF) in urine samples. To optimize the key experimental variables including extraction temperature, extraction time, salt concentration, and stirring speed, a central composite design-response surface methodology (CCD-RSM) was employed. The optimal values for extraction in the study were found to be 51.2 °C extraction temperature, 46.2 min extraction time, 27 % salt concentration, and 620 rpm stirring speed. Under the optimized conditions, the calibration curves demonstrated excellent linearity within the range of 0.1-100 µg L-1, with correlation coefficients (R2) exceeding 0.99. The limits of detection (LODs) for MTBE, ETBE, and TBF were obtained 0.06, 0.08, and 0.09 µg L-1, respectively. Moreover, the limits of quantification (LOQs) for MTBE, ETBE, and TBF were obtained 0.18, 0.24, and 0.27 µg L-1, respectively. The enrichment factor was also found to be in the range of 98-129.The NTD-GC-FID procedure demonstrated a high extraction efficiency, making it a promising tool for urinary biomonitoring of fuel ether oxygenates with improved sensitivity and selectivity compared to current methods.


Assuntos
Limite de Detecção , Éteres Metílicos , Zeolitas , Zeolitas/química , Humanos , Éteres Metílicos/urina , Éteres Metílicos/química , Polímeros Molecularmente Impressos/química , Monitoramento Biológico/métodos , Cromatografia Gasosa/métodos , Etil-Éteres/urina , Etil-Éteres/química
8.
Environ Geochem Health ; 46(5): 161, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38592512

RESUMO

Hexavalent chromium (Cr (VI)) is an environmental contaminant brining high concerns due to its higher toxicity and mobility in comparison with trivalent chromium Cr(III). Cr (VI) has been linked with several adverse health effects, including respiratory diseases, lung cancer, and skin irritation. The primary sources of it in the environment are industrial activities.Most of the time, fly ash made of lignite can release Cr(VI) when it comes into contact with water in an aquatic environment. The objective of this study is the investigation of Cr (VI) concentration in leachates of fly ash and marl mixtures and the determination of its solubility under different pH conditions. Samples of fly ash were collected from the Power Plant of Agios Dimitrios. Additionally, samples of marl were collected from the mine of South Field, and both samples were mixed and prepared in in different proportions (% w.t.). The leaching experiments were carried out according to the EN-12457/1-4 (2003) standard under different pH conditions and chemical analysis of the leachates were performed by spectrophotometry with diphenylcarbazide (DPC). The environmental footprint of Cr (VI) in the study area was significant, especially in mixtures containing higher concentrations of fly ash. A critical pH range between 6 to 12 is observed. At acidic pH values, a high release of Cr (VI) was observed, while at the mentioned critical values (pH 10-12), a gradual decrease in its leachability was noticed. The high concentrations of Cr (VI) in the industrial area studied require immediate actions in terms of managing and limiting the potential hazardous impacts on the environment and by extension on the public health by developing appropriate prevention strategies.


Assuntos
Cromo , Cinza de Carvão , Humanos , Grécia , Cromo/toxicidade , Cromatografia Gasosa
9.
J Chromatogr A ; 1722: 464869, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38604057

RESUMO

Hydrodynamics, efficiency, and loading capacity of two semi-packed columns with different cross sections (NANO 315 µm x 18 µm; CAP 1000 µm x 28 µm) and similar pillar diameter and pillar-pillar distance (respectively 5 µm and 2.5 µm) have been compared in high-pressure gas chromatography. A flow prediction tool has been first designed to determine pressure variations and hold-up time across the chromatographic system taking into account the rectangular geometry of the ducts into the semi-packed columns. Intrinsic values of Height Equivalent to Theoretical Plate were determined for NANO and CAP columns using helium as carrier gas and similar values have been obtained (30 µm) for the two columns. Loading capacity of semi-packed columns were determined for decane at 70 °C using helium, and the highest value was obtained from CAP column (larger cross section and stationary phase content). Finally, significant HETP improvement (down to 15 µm) and peak shape were observed when carbon dioxide was used as carrier gas, suggesting mobile phase adsorption on stationary phase in high pressure conditions.


Assuntos
Hélio , Pressão , Cromatografia Gasosa/métodos , Cromatografia Gasosa/instrumentação , Hélio/química , Hidrodinâmica , Dióxido de Carbono/química , Adsorção
10.
J Pharm Biomed Anal ; 244: 116128, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38598924

RESUMO

Genotoxic impurities (GTIs) are potential carcinogens that need to be controlled down to ppm or lower concentration levels in pharmaceuticals under strict regulations. The static headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD) is an effective approach to monitor halogenated and nitroaromatic genotoxins. Deep eutectic solvents (DESs) possess tunable physico-chemical properties and low vapor pressure for HS-GC methods. In this study, zwitterionic and non-ionic DESs have been used for the first time to develop and validate a sensitive analytical method for the analysis of 24 genotoxins at sub-ppm concentrations. Compared to non-ionic diluents, zwitterionic DESs produced exceptional analytical performance and the betaine : 7 (1,4- butane diol) DES outperformed the betaine : 5 (1,4-butane diol) DES. Limits of detection (LOD) down to the 5-ppb concentration level were achieved in DESs. Wide linear ranges spanning over 5 orders of magnitude (0.005-100 µg g-1) were obtained for most analytes with exceptional sensitivities and high precision. The method accuracy and precision were validated using 3 commercially available drug substances and excellent recoveries were obtained. This study broadens the applicability of HS-GC in the determination of less volatile GTIs by establishing DESs as viable diluent substitutes for organic solvents in routine pharmaceutical analysis.


Assuntos
Solventes Eutéticos Profundos , Contaminação de Medicamentos , Limite de Detecção , Mutagênicos , Contaminação de Medicamentos/prevenção & controle , Cromatografia Gasosa/métodos , Mutagênicos/análise , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/química , Solventes Eutéticos Profundos/química , Solventes Eutéticos Profundos/análise , Química Verde/métodos , Reprodutibilidade dos Testes , Solventes/química
11.
Mikrochim Acta ; 191(4): 226, 2024 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-38558261

RESUMO

The focus of this paper is laid on synthesizing layered compounds of CuMoO4 and Ti3C2Tx using a simple wet chemical etching method and sonochemical method to enable rapid detection of rutin using an electrochemical sensor. Following structural examinations using XRD, surface morphology analysis using SEM, and chemical composition state analysis using XPS, the obtained CuMoO4/Ti3C2Tx nanocomposite electrocatalyst was confirmed and characterized. By employing cyclic voltammetry and differential pulse voltammetry, the electrochemical properties of rutin on a CuMoO4/Ti3C2Tx modified electrode were examined, including its stability and response to variations in pH, loading, sweep rate, and interference. The CuMoO4/Ti3C2Tx modified electrode demonstrates rapid rutin sensing under optimal conditions and offers a linear range of 1 µΜ to 15 µΜ, thereby improving the minimal detection limit (LOD) to 42.9 nM. According to electrochemical analysis, the CuMoO4/Ti3C2Tx electrode also demonstrated cyclic stability and long-lasting anti-interference capabilities. The CuMoO4/Ti3C2Tx nanocomposite demonstrated acceptable recoveries when used to sense RT in apple and grape samples. In comparison to other interfering sample analytes encountered in the current study, the developed sensor demonstrated high selectivity and anti-interference performance. As a result, our research to design of high-performance electrochemical sensors in the biomedical and therapeutic fields.


Assuntos
Antioxidantes , Nanocompostos , Titânio , Cromatografia Gasosa , Rutina
12.
Methods Mol Biol ; 2790: 427-438, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38649585

RESUMO

The biological role of lipids goes far beyond the formation of a structural membrane bilayer platform for membrane proteins and controlling fluxes across the membranes. For example, in photosynthetic thylakoid membranes, lipids occupy well-defined binding niches within protein complexes and determine the structural organization of membrane proteins and their function by controlling generic physicochemical membrane properties. In this chapter, two-dimensional thin-layer chromatography (2D TLC) and gas chromatography (GC) techniques are presented for quantitative analysis of lipid classes and fatty acids in thylakoid membranes. In addition, lipid extraction methods from isolated thylakoid membranes and leaves are described together with a procedure for the derivatization of fatty acids to fatty acid methyl esters (FAME) that is required for GC analysis.


Assuntos
Ácidos Graxos , Fotossíntese , Tilacoides , Tilacoides/metabolismo , Cromatografia em Camada Fina/métodos , Cromatografia Gasosa/métodos , Ácidos Graxos/metabolismo , Ácidos Graxos/química , Lipídeos de Membrana/metabolismo , Lipídeos de Membrana/química , Folhas de Planta/metabolismo , Folhas de Planta/química , Lipídeos/química , Lipídeos/isolamento & purificação , Lipídeos/análise
13.
J Chromatogr A ; 1721: 464812, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38569297

RESUMO

In this work, a novel and efficient approach for sodium hypochlorite analysis is proposed via phase-conversion headspace technique, which is based on the gas chromatography (GC) detection of generated carbon dioxide (CO2) from the redox reaction of sodium hypochlorite with sodium oxalate. The data obtained by the proposed method suggest the high detecting precision and accuracy. In addition, the method has low detection limits (limit of quantification (LOQ) = 0.24 µg/mL), and the recoveries of added standard ranged from 98.33 to 101.27 %. The proposed phase-conversion headspace technique is efficient and automated, thereby offering an efficient strategy for highly efficient analysis of sodium hypochlorite and related products.


Assuntos
Desinfetantes , Hipoclorito de Sódio , Desinfetantes/análise , Ácido Hipocloroso , Cromatografia Gasosa/métodos , Dióxido de Carbono/análise
14.
J Synchrotron Radiat ; 31(Pt 3): 566-577, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38682274

RESUMO

Improving the scalability of tissue imaging throughput with bright, coherent X-rays requires identifying and mitigating artifacts resulting from the interactions between X-rays and matter. At synchrotron sources, long-term imaging of soft tissues in solution can result in gas bubble formation or cavitation, which dramatically compromises image quality and integrity of the samples. By combining in-line phase-contrast imaging with gas chromatography in real time, we were able to track the onset and evolution of high-energy X-ray-induced gas bubbles in ethanol-embedded soft tissue samples for tens of minutes (two to three times the typical scan times). We demonstrate quantitatively that vacuum degassing of the sample during preparation can significantly delay bubble formation, offering up to a twofold improvement in dose tolerance, depending on the tissue type. However, once nucleated, bubble growth is faster in degassed than undegassed samples, indicating their distinct metastable states at bubble onset. Gas chromatography analysis shows increased solvent vaporization concurrent with bubble formation, yet the quantities of dissolved gasses remain unchanged. By coupling features extracted from the radiographs with computational analysis of bubble characteristics, we uncover dose-controlled kinetics and nucleation site-specific growth. These hallmark signatures provide quantitative constraints on the driving mechanisms of bubble formation and growth. Overall, the observations highlight bubble formation as a critical yet often overlooked hurdle in upscaling X-ray imaging for biological tissues and soft materials and we offer an empirical foundation for their understanding and imaging protocol optimization. More importantly, our approaches establish a top-down scheme to decipher the complex, multiscale radiation-matter interactions in these applications.


Assuntos
Síncrotrons , Raios X , Animais , Gases/química , Cromatografia Gasosa/métodos , Etanol/química
15.
Molecules ; 29(7)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38611821

RESUMO

This study aimed to investigate the volatile flavor compounds and tastes of six kinds of sauced pork from the southwest and eastern coastal areas of China using gas chromatography-ion mobility spectroscopy (GC-IMS) combined with an electronic nose (E-nose) and electronic tongue (E-tongue). The results showed that the combined use of the E-nose and E-tongue could effectively identify different kinds of sauced pork. A total of 52 volatile flavor compounds were identified, with aldehydes being the main flavor compounds in sauced pork. The relative odor activity value (ROAV) showed that seven key volatile compounds, including 2-methylbutanal, 2-ethyl-3, 5-dimethylpyrazine, 3-octanone, ethyl 3-methylbutanoate, dimethyl disulfide, 2,3-butanedione, and heptane, contributed the most to the flavor of sauced pork (ROAV ≥1). Multivariate data analysis showed that 13 volatile compounds with the variable importance in projection (VIP) values > 1 could be used as flavor markers to distinguish six kinds of sauced pork. Pearson correlation analysis revealed a significant link between the E-nose sensor and alcohols, aldehydes, terpenes, esters, and hetero-cycle compounds. The results of the current study provide insights into the volatile flavor compounds and tastes of sauced pork. Additionally, intelligent sensory technologies can be a promising tool for discriminating different types of sauced pork.


Assuntos
Carne de Porco , Carne Vermelha , Suínos , Animais , Nariz Eletrônico , China , Análise Espectral , Aldeídos , Cromatografia Gasosa
16.
Int J Mol Sci ; 25(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38612781

RESUMO

Poplars provide medicinal raw plant materials used in pharmacy. Leaf buds are one of the herbal medicinal products collected from poplars, having anti-inflammatory and antiseptic properties, but there are no quality standards for their production and there is a need to determine their botanical sources. Therefore, the chemical compositions of the leaf buds from four species and varieties of poplars, Populus balsamifera, P. × berolinensis, P. × canadensis 'Marilandica', and P. wilsonii were investigated and compared using gas chromatography coupled with mass detection (GC-MS) and two-dimensional high-performance thin-layer chromatography (2D-HPTLC) in order to search for taxa characterized by a high content of biologically active compounds and with a diverse chemical composition that determines their therapeutic effects. The presence of 163 compounds belonging to the groups of flavonoids, phenolic acids derivatives, glycerides, and sesquiterpenes was revealed. Moreover, the conditions for the separation and identification of biologically active compounds occurring in analyzed leaf buds using 2D-HPTLC were optimized and used for metabolomic profiling of the studied poplars, enabling their fast and simple botanical identification. The total phenolic (TPC) and flavonoid (TFC) contents of examined extracts were determined and their antioxidant capacities were estimated by spectrophotometric DPPH, ABTS, and FRAP assays. Based on the analysis of phytochemicals and antioxidant activity, P. × berolinensis buds were selected as the raw plant material for medicinal purposes with the highest content of active compounds and the strongest antioxidant activity.


Assuntos
Antioxidantes , Populus , Cromatografia em Camada Fina , Cromatografia Gasosa , Flavonoides , Folhas de Planta
17.
J Agric Food Chem ; 72(17): 9523-9554, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38640191

RESUMO

Gas chromatography-olfactometry (GC-O) has made significant advancements in recent years, with breakthroughs in its applications and the identification of its limitations. This technology is widely used for analyzing complex odor patterns. The review begins by explaining the principles of GC-O, including sample preparation, separation methods, and olfactory evaluation techniques. It then explores the diverse range of applications where GC-O has found success, such as food and beverage industries, environmental monitoring, perfume and aroma development, and forensic analysis. One of the major breakthroughs in GC-O analysis is the improvement in separation power and resolution of odorants. Techniques like rapid GC, comprehensive two-dimensional GC, and multidimensional GC have enhanced the identification and quantification of odor-active chemicals. However, GC-O also has limitations. These include the challenges in detecting and quantifying trace odorants, dealing with matrix effects, and ensuring the repeatability and consistency of results across laboratories. The review examines these limitations closely and discusses potential solutions and future directions for improvement in GC-O analysis. Overall, this review presents a comprehensive overview of the recent advances in GC-O, covering breakthroughs, applications, and limitations. It aims to promote the wider usage of GC-O analysis in odor analysis and related industries. Researchers, practitioners, and anyone interested in leveraging the capabilities of GC-O in analyzing complex odor patterns will find this review a valuable resource. The article highlights the potential of GC-O and encourages further research and development in the field.


Assuntos
Odorantes , Olfatometria , Odorantes/análise , Olfatometria/métodos , Cromatografia Gasosa/métodos , Cromatografia Gasosa/instrumentação , Humanos , Olfato , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/química
18.
Se Pu ; 42(4): 387-392, 2024 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-38566428

RESUMO

The residual amount of halogenated solvents in olive oil is an important indicator of its quality. The National Olive Oil Quality Standard GB/T 23347-2021 states that the residual amount of individual halogenated solvents in olive oil should be ≤0.1 mg/kg and that the total residual amount of halogenated solvents should be ≤0.2 mg/kg. COI/T.20/Doc. No. 8-1990, which was published by the International Olive Council, describes the standard method used for the determination of halogenated solvents in olive oil. Unfortunately, this method is cumbersome, has poor repeatability and low automation, and is unsuitable for the detection and analysis of residual halogenated solvents in large quantities of olive oil. At present, no national standard method for determining residual halogenated solvents in olive oil is available in China. Thus, developing simple, efficient, accurate, and stable methods for the determination of residual halogenated solvents in olive oil is imperative. In this paper, a method based on automatic headspace gas chromatography was established for the determination of residual halogenated solvents, namely, chloroform, carbon tetrachloride, 1,1,1-trichloroethane, dibromochloromethane, tetrachloroethylene, and bromoform, in olive oil. The samples were processed as follows. After mixing, 2.00 g (accurate to 0.01 g) of the olive oil sample was added into a 20 mL headspace injection bottle and immediately sealed for headspace gas chromatography analysis. Blank virgin olive oil was used to prepare a standard working solution and the external standard method for quantification. The solvents used in the preparation of halogenated solvent standard intermediates were investigated and methanol was selected as a replacement for N,N-dimethylacetamide to prepare a halogenated solvent standard intermediate owing to its safety. The effects of different injection times (1, 2, 3, 4, 5, 6 s), equilibration temperatures (60, 70, 80, 90, 100, 110, 120 ℃), and equilibration times (4, 5, 8, 10, 20, 30, 40 min) of the headspace sampler on the detection of the residual amounts of the six halogenated solvents were investigated. The optimal injection time and equilibration temperature were 3 s and 90 ℃, respectively. The method demonstrated good analytical performance for the six halogenated solvents when the equilibration time was 30 min. A methodological study was conducted on the optimized method, and the results showed that the six halogenated solvents exhibited good linear relationships in the range of 0.002-0.200 mg/kg, with correlation coefficients of ≥0.9991. The limits of detection (LODs) and quantification (LOQs) of 1,1,1-trichloroethane and bromoform were 0.0006 and 0.002 mg/kg, respectively. The LODs and LOQs of chloroform, carbon tetrachloride, dibromochloromethane, and tetrachloroethylene were 0.0003 and 0.001 mg/kg, respectively. The average recoveries under different spiked levels were 85.53%-115.93%, and the relative standard deviations (n=6) were 1.11%-8.48%. The established method was used to analyze 13 olive oil samples available in the market. Although no halogenated solvents were detected in these samples, a limited number of samples does not represent all olive oils. Hence, monitoring residual halogenated solvents in olive oil remains necessary for its safe consumption. The LOQs of the method for the six halogenated solvents were significantly lower than that of the COI/T.20/Doc. No. 8-1990 standard method (0.02 mg/kg). In addition, the developed method can be conducted under short operation times with high precision and degree of automation as well as good accuracy. Thus, the proposed method is suitable for the determination and analysis of the residues of the six halogenated solvents in large batches of olive oil samples.


Assuntos
Tetracloroetileno , Tricloroetanos , Azeite de Oliva , Solventes/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Tetracloroetileno/análise , Clorofórmio/análise , Tetracloreto de Carbono/análise , Cromatografia Gasosa/métodos , Trialometanos
19.
Environ Sci Pollut Res Int ; 31(17): 25033-25045, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38466382

RESUMO

Polybrominated diphenyl ethers (PBDEs) are a group of compounds that, due to their applications, are considered mainly indoor contaminants. To obtain the first information about the presence of PBDEs in Serbia, dust samples (n = 50) were collected in settlements in the northern Serbian province of Vojvodina. The selected/target congeners (BDE-28, 47, 99, 100, 153, 154, and 183) were extracted from house dust by microwave-assisted extraction technique, and purified extracts were analyzed on a dual-column gas chromatograph with micro-electron capture detectors. A wide range of ΣPBDEs was detected (0.295 to 394 ng g-1 dust), which reflects large differences in contamination among the examined homes. For the majority of samples (72%), ΣPBDEs were lower than 5 ng g-1 indicating that people living in Vojvodina province are exposed to low concentrations of PBDEs present in their households. Based on principal component analysis (PCA), balcony areas and age of the house positively correlate with the PBDE congeners with higher detection frequencies (≥ 50%), namely, with BDE-99, BDE-153, and BDE-183. Statistically significant positive correlation (p < 0.01) was obtained for BDE-99 and the number of household's members. Estimated daily intakes (EDItot) were calculated for ingestion and dermal absorption of dust for two age groups-adults and toddlers. These are the first data on PBDE status in the area of the Western Balkan, and the health risk assessment indicates that PBDE levels obtained in household dust do not pose a risk for human health.


Assuntos
Poluição do Ar em Ambientes Fechados , Éteres Difenil Halogenados , Adulto , Humanos , Éteres Difenil Halogenados/análise , Sérvia , Poeira/análise , Poluição do Ar em Ambientes Fechados/análise , Cromatografia Gasosa , Medição de Risco , Exposição Ambiental/análise , Monitoramento Ambiental
20.
J Agric Food Chem ; 72(14): 8081-8091, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38535975

RESUMO

Culinary sage, Salvia officinalis L., is a popular spice plant commonly used throughout the world. In this study, 35 odorants were identified in dried sage via solvent-assisted flavor evaporation (SAFE) and aroma extract dilution analysis (AEDA), including 9 that were identified in sage for the first time. Fifteen odorants were quantitated by stable isotope dilution analysis (SIDA), and their odor activity values (OAVs) were determined. Odorants with high OAVs included (2E,6Z)-nona-2,6-dienal, 1,8-cineole, and ß-myrcene. A formulated aroma simulation model closely matched the aroma profile of an aqueous infusion of dried sage. Enantiomeric proportions of selected odorants were determined by chiral gas chromatography. Furthermore, 6 different sage cultivars were grown in the greenhouse, dried under the same conditions, and analyzed. Sensory analysis determined that all cultivars were dominated by an herbaceous sensory attribute and had varying intensities of eucalyptus, mint, clove, pine, green, earthy, floral, and citrus notes. Cultivars with varying intensities of herbaceous, eucalyptus, pine, and green sensory notes correlated with the OAVs of α-thujone/ß-thujone, 1,8-cineole, α-pinene, and (2E,6Z)-nona-2,6-dienal, respectively. This study identified the odorants driving the sensory profiles of different sage cultivars and serves as a foundation for future studies on the aroma chemistry of culinary sage.


Assuntos
Salvia officinalis , Compostos Orgânicos Voláteis , Odorantes/análise , Eucaliptol/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Gasosa , Compostos Orgânicos Voláteis/química , Aromatizantes/química , Olfatometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA