Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 15.177
Filtrar
1.
J Microbiol Methods ; 221: 106942, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38704038

RESUMO

Methylation analysis was performed on methylated alditol acetate standards and Streptococcus mutans extracellular polymeric substances (EPS) produced from wild-type and Gtf knockout strains (∆GtfB, ∆GtfB, and ∆GtfD). The methylated alditol acetate standards were representative of glycosidic linkages found in S. mutans EPS and were used to calibrate the GC-MS system for an FID detector and MS (TIC) and produce molar response factor, a necessary step in quantitative analysis. FID response factors were consistent with literature values (Sweet et al., 1975) and found to be the superior option for quantitative results, although the TIC response factors now give researchers without access to an FID detector a needed option for molar response factor correction. The GC-MS analysis is then used to deliver the ratio of the linkage types within a biofilm.


Assuntos
Biofilmes , Cromatografia Gasosa-Espectrometria de Massas , Polissacarídeos Bacterianos , Streptococcus mutans , Biofilmes/crescimento & desenvolvimento , Streptococcus mutans/genética , Streptococcus mutans/metabolismo , Cromatografia Gasosa-Espectrometria de Massas/métodos , Polissacarídeos Bacterianos/metabolismo , Glicosídeos/metabolismo , Metilação , Matriz Extracelular de Substâncias Poliméricas/metabolismo , Matriz Extracelular de Substâncias Poliméricas/química , Polissacarídeos/metabolismo
2.
Anal Chim Acta ; 1307: 342624, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719414

RESUMO

BACKGROUND: Pesticides are used in agricultural production for prevent and control crop diseases and pests, but it is easy to cause excessive pesticides residues in agricultural products, polluting the environment and endangering human health. Due to their unmatched and sustainable capabilities, nanoextraction procedures are becoming every day more important in Analytical Chemistry. In particular, nanoconfined liquid phase extraction has shown extraction capabilities toward polar, medium polar, and/or nonpolar substances, which can be easily modulated depending on the nanoconfined solvent used. Furthermore, this "green" technique showed excellent characteristics in terms of recoveries, extraction time (≤1 min), reliability, and versatility. (97) RESULTS: In this work, the advantages of this technique have been coupled with those of filtration membrane extraction, making use of carbon nanofibers (CnFs) growth on carbon microspheres (CµS). This substrate has been deposited on a filter, which combined with gas chromatographic mass spectrometry (GC-MS) analysis successfully employed for the nanoextraction of 30 pesticides (18 organochlorine and 12 pyrethroids) in tea samples. Under the optimized extraction conditions, the linear range with standard solutions was from 1 to 1000 ng mL-1 (R2 ≥ 0.99), the limit of detections in tea samples were in the range 0.56-17.98 µg kg-1. The accuracy of the developed method was evaluated by measuring the extraction recovery of the spiked tea samples, and recoveries between 74.41 % and 115.46 %. (119) SIGNIFICANCE: Considering the versatility of nanoconfined liquid phase extraction and the functionality of the filtration membrane extraction procedure, this new extraction method can be considered a powerful candidate for automatized high-throughput analyses of real samples. (34).


Assuntos
Filtração , Hidrocarbonetos Clorados , Extração Líquido-Líquido , Praguicidas , Piretrinas , Chá , Chá/química , Piretrinas/análise , Piretrinas/isolamento & purificação , Hidrocarbonetos Clorados/análise , Hidrocarbonetos Clorados/isolamento & purificação , Extração Líquido-Líquido/métodos , Filtração/métodos , Praguicidas/análise , Praguicidas/isolamento & purificação , Cromatografia Gasosa-Espectrometria de Massas/métodos , Membranas Artificiais
3.
Food Res Int ; 186: 114319, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38729690

RESUMO

The "outstanding and unique aged aroma" of Chinese Chenxiang-type baijiu (CXB)-Daoguang 25 (DG25) mainly originates from a "extraordinary storage technology" of Mujiuhai (a wooden container), so it is mysterious and interesting. In this study, an untargeted GC/MS-based metabolomics was used to reveals the volatile differential metabolites for discriminating six different vintages of DG25 combing with chemometrics. A total of 100 volatile metabolites (including unknowns) were extracted and identified, including esters (41%), alcohols (10%) and acids (7%) so on. Finally, 33 differential metabolites were identified as aging-markers. Among them, 25 aging-markers showed a downtrend, including 17 esters such as ethyl acetate, ethyl hexanoate and ethyl palmitate so on. Moreover, it was interesting and to further study that furans showed a significant downtrend. Statistically speaking, ethyl benzoate played an important role in discriminating vintage of 1Y and 3Y, and the other 24 differential metabolites with downtrend discriminating the unstored (0Y-aged) DG25. Eight differential metabolites, such as ethyl octanoate, benzaldehyde, 3-methylbutanol and 1,1-diethoxyaccetal so on increased during aging of DG25, and they played a statistical role in discriminating the 5Y-, 10Y- and 20Y-aged DG25. This study provides a theoretical basis way for the formation mechanism of aging aroma for CXB.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Metabolômica , Odorantes , Compostos Orgânicos Voláteis , Cromatografia Gasosa-Espectrometria de Massas/métodos , Metabolômica/métodos , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/metabolismo , Odorantes/análise , Vinho/análise , Bebidas Alcoólicas/análise
4.
Rapid Commun Mass Spectrom ; 38(14): e9764, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-38714901

RESUMO

RATIONALE: Various medium formulations contain essential fatty acids at concentrations ranging from 10 to 100 mg/L. Accurate and precise lipid measurement in media is crucial for monitoring media quality and conducting studies on lipids in the context of cell culture. This study employed two-dimensional gas chromatography (GC × GC) analyses to offer enhanced resolution, sensitivity, and separation performance compared to GC. METHODS: Quantification of fatty acid methyl esters (FAMEs) in a medium was conducted using GC × GC combined with a high-resolution mass spectrometer and flame ionization detector, considering potential interference from nonionic surfactant Tween 80, which was precipitated and removed by optimizing the concentration of cobalt thiocyanate (CTA) solution during pretreatment. This advanced analytical approach enabled identification of cis and trans isomers of identical molecular weights and determination of the location and number of double bonds in the same carbon number structure. RESULTS: Our analysis identified 36 FAMEs within the C6-C24 region, and a 5% CTA solution was optimal for efficient removal of Tween 80 during lipid extraction. Additionally, this advanced method minimized FAME contamination and loss during pretreatment, thereby significantly reducing the sample volume required to detect trace levels of FAMEs. This improvement led to a fatty acid recovery rate of 106% while maintaining the average relative standard deviation for the target FAMEs of about 3%. CONCLUSIONS: Our research paves the way for future investigation into medium quality control and the role of fatty acids in cell culture. This offers the possibility for economical and effective trace quantification of fatty acids in complex media.


Assuntos
Ácidos Graxos , Ácidos Graxos/análise , Ácidos Graxos/química , Meios de Cultura/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Polissorbatos/química , Polissorbatos/análise
5.
Sci Rep ; 14(1): 10303, 2024 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-38705886

RESUMO

Depression is a serious psychiatric illness that causes great inconvenience to the lives of elderly individuals. However, the diagnosis of depression is somewhat subjective. Nontargeted gas chromatography (GC)/liquid chromatography (LC)-mass spectrometry (MS) was used to study the plasma metabolic profile and identify objective markers for depression and metabolic pathway variation. We recruited 379 Chinese community-dwelling individuals aged ≥ 65. Plasma samples were collected and detected by GC/LC‒MS. Orthogonal partial least squares discriminant analysis and a heatmap were utilized to distinguish the metabolites. Receiver operating characteristic curves were constructed to evaluate the diagnostic value of these differential metabolites. Additionally, metabolic pathway enrichment was performed to reveal metabolic pathway variation. According to our standard, 49 people were included in the depression cohort (DC), and 49 people age- and sex-matched individuals were included in the non-depression cohort (NDC). 64 metabolites identified via GC‒MS and 73 metabolites identified via LC‒MS had significant contributions to the differentiation between the DC and NDC, with VIP values > 1 and p values < 0.05. Three substances were detected by both methods: hypoxanthine, phytosphingosine, and xanthine. Furthermore, 1-(sn-glycero-3-phospho)-1D-myo-inositol had the largest area under the curve (AUC) value (AUC = 0.842). The purine metabolic pathway is the most important change in metabolic pathways. These findings show that there were differences in plasma metabolites between the depression cohort and the non-depression cohort. These identified differential metabolites may be markers of depression and can be used to study the changes in depression metabolic pathways.


Assuntos
Depressão , Metabolômica , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Biomarcadores/sangue , China , Cromatografia Líquida/métodos , Depressão/sangue , Depressão/metabolismo , População do Leste Asiático , Cromatografia Gasosa-Espectrometria de Massas/métodos , Redes e Vias Metabólicas , Metaboloma , Metabolômica/métodos , Curva ROC
6.
Molecules ; 29(9)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38731560

RESUMO

2, 6-diisopropylaniline (2, 6-DIPA) is a crucial non-intentionally organic additive that allows the assessment of the production processes, formulation qualities, and performance variations in biodegradable mulching film. Moreover, its release into the environment may have certain effects on human health. Hence, this study developed simultaneous heating hydrolysis-extraction and amine switchable hydrophilic solvent vortex-assisted homogeneous liquid-liquid microextraction for the gas chromatography-mass spectrometry analysis of the 2, 6-DIPA additive and its corresponding isocyanates in poly(butylene adipate-co-terephthalate) (PBAT) biodegradable agricultural mulching films. The heating hydrolysis-extraction conditions and factors influencing the efficiency of homogeneous liquid-liquid microextraction, such as the type and volume of amine, homogeneous-phase and phase separation transition pH, and extraction time were investigated and optimized. The optimum heating hydrolysis-extraction conditions were found to be a H2SO4 concentration of 2.5 M, heating temperature of 87.8 °C, and hydrolysis-extraction time of 3.0 h. As a switchable hydrophilic solvent, dipropylamine does not require a dispersant. Vortex assistance is helpful to speed up the extraction. Under the optimum experimental conditions, this method exhibits a better linearity (0.0144~7.200 µg mL-1 with R = 0.9986), low limit of detection and quantification (0.0033 µg g-1 and 0.0103 µg g-1), high extraction recovery (92.5~105.4%), desirable intra- and inter-day precision (relative standard deviation less than 4.1% and 4.7%), and high enrichment factor (90.9). Finally, this method was successfully applied to detect the content of the additive 2, 6-DIPA in PBAT biodegradable agricultural mulching films, thus facilitating production process monitoring or safety assessments.


Assuntos
Aminas , Compostos de Anilina , Cromatografia Gasosa-Espectrometria de Massas , Interações Hidrofóbicas e Hidrofílicas , Microextração em Fase Líquida , Solventes , Microextração em Fase Líquida/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Solventes/química , Aminas/química , Aminas/análise , Compostos de Anilina/química , Hidrólise , Poliésteres/química
7.
Molecules ; 29(9)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38731605

RESUMO

The aim of this study is to develop a rapid and accurate method for simultaneous analysis of multi-residue pesticides and conduct pesticide monitoring in agricultural products produced by the production and distribution stage in Korea. The representative agricultural products were selected as brown rice, soybean, potato, mandarin, and green pepper and developed using gas chromatography with tandem mass (GC-MS/MS) for the analysis of 272 pesticide residues. The experimental samples were extracted by the QuEChERS-EN method and then cleaned up by using d-SPE, including MgSO4 and primary secondary amine (PSA) sorbents. The established method was validated in accordance with Codex CAC-GL/40, and the limit of quantitation (LOQ) was determined to be 0.01 mg/kg. A total of 243 pesticides satisfied the guidelines in five samples at three levels with values of 60 to 120% (recovery) and ≤45% (coefficient of variation, CV). The remaining 29 pesticides did not satisfy the guidelines, and these pesticides are expected to be used as a screening method for the routine inspection of agricultural products. As a result of analyzing 223 agricultural products in South Korea by applying the simultaneous analysis method, none of the detected levels in the samples exceeded the standard values based on maximum residue limits (MRLs). The developed method in this study will be used to inspect residual pesticides in agricultural products, and it is anticipated to contribute to the distribution of safe agricultural products to consumers.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Resíduos de Praguicidas , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Resíduos de Praguicidas/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Praguicidas/análise , Produtos Agrícolas/química , República da Coreia , Contaminação de Alimentos/análise , Limite de Detecção , Extração em Fase Sólida/métodos
8.
J Chromatogr A ; 1726: 464963, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38723493

RESUMO

The monitoring of organic compounds in aquatic matrices poses challenges due to its complexity and time-intensive nature. To address these challenges, we introduce a novel approach utilizing a dual-channel mono (1D) and comprehensive two-dimensional (2D) gas chromatography coupled with time-of-flight mass spectrometry (GC × GC-TOFMS) system, integrated with a robotic pretreatment platform, for online monitoring of both volatile organic compounds (VOCs) and semivolatile organic compounds (SVOCs) in water matrices. Employing the robotic platform, we establish a suite of online liquid-liquid extraction (LLE) pretreatment processes for water samples, marking the first instance of such procedures. Leveraging the automatic headspace (HS) module, dual robotic preparations of HS and LLE are sequentially executed to extract VOCs and SVOCs from water matrices. The GC × GC-TOFMS system is distinguished by its dual-channel analytical column configuration, facilitating sequential analysis of VOCs in GC-TOFMS mode and SVOCs in GC × GC-TOFMS mode. Quantitative detection of 55 target VOCs and 104 SVOCs is achieved in a water sample using the instrument system. Our method demonstrates excellent correlation coefficients ranging from 0.990 to 1.000, method detection limits ranging from 0.08 to 4.78 µg L-1, relative standard deviations below 19.3 %, and recovery rates ranging from 50.0 % to 124.0 %. To validate the online monitoring capabilities of our system, we assess target SVOCs at three different concentration levels over a 3-day period. Most compounds exhibit recovery rates ranging from 70.0 % to 130.0 %. Furthermore, we apply our method to analyze a real water sample, successfully identifying over 100 target and nontarget VOCs/SVOCs, including alcohols, aldehydes, ketones, acids, esters, and phenols. These results highlight the efficacy of the proposed analysis system, capable of conducting two distinct analyses in automatic sequence, thereby enhancing the efficiency and accuracy of organic compound analysis in water matrices.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Extração Líquido-Líquido , Robótica , Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/isolamento & purificação , Cromatografia Gasosa-Espectrometria de Massas/métodos , Extração Líquido-Líquido/métodos , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação , Limite de Detecção
9.
J Pharm Biomed Anal ; 245: 116196, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38723559

RESUMO

Osteoarthritis (OA) is a degenerative joint disease primarily affecting the cartilage. The therapeutic potential of the Dipsacus asper-Achyranthes bidentate herb pair for OA has been acknowledged, yet its precise mechanism remains elusive. In this study, we conducted a comprehensive analysis of metabolomic changes and therapeutic outcomes in osteoarthritic rats, employing a gas chromatography-mass spectrometry-based metabolomics approach in conjunction with histopathological and biochemical assessments. The rats were divided into six groups: control, model, positive control, Dipsacus asper treated, Achyranthes bidentata treated, and herb pair treated groups. Compared to the model group, significant reductions in levels of tumor necrosis factor-α (TNF-α), interleukin-1ß (IL-1ß), interleukin-6 (IL-6), and iNOS were observed in the treated groups. Multivariate statistical analyses were employed to investigate metabolite profile changes in serum samples and identify potential biomarkers, revealing 45 differential biomarkers, with eighteen validated using standard substances. These analytes exhibited excellent linearity across a wide concentration range (R2>0.9990), with intra- and inter-day precision RSD values below 4.69% and 4.83%, respectively. Recoveries of the eighteen analytes ranged from 93.97% to 106.59%, with RSD values under 5.72%, underscoring the method's reliability. Treatment with the herbal pair effectively restored levels of unsaturated fatty acids such as linoleic acid and arachidonic acid, along with glucogenic amino acids. Additionally, levels of phosphoric acid and citric acid were reversed, indicating restoration of energy metabolism. Collectively, these findings highlight the utility of metabolomic analysis in evaluating therapeutic efficacy and elucidating the underlying molecular mechanisms of herb pairs in OA treatment.


Assuntos
Achyranthes , Biomarcadores , Metabolismo Energético , Ácidos Graxos Insaturados , Cromatografia Gasosa-Espectrometria de Massas , Metabolômica , Osteoartrite , Ratos Sprague-Dawley , Animais , Metabolômica/métodos , Osteoartrite/tratamento farmacológico , Osteoartrite/metabolismo , Achyranthes/química , Ratos , Metabolismo Energético/efeitos dos fármacos , Masculino , Cromatografia Gasosa-Espectrometria de Massas/métodos , Ácidos Graxos Insaturados/metabolismo , Ácidos Graxos Insaturados/sangue , Biomarcadores/sangue , Dipsacaceae/química , Modelos Animais de Doenças , Medicamentos de Ervas Chinesas/farmacologia , Medicamentos de Ervas Chinesas/uso terapêutico , Extratos Vegetais/farmacologia , Extratos Vegetais/uso terapêutico
10.
J Agric Food Chem ; 72(20): 11438-11451, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38728027

RESUMO

The spreading awareness of the health benefits associated with the consumption of plant-based foods is fueling the market of innovative vegetable products, including microgreens, recognized as a promising source of bioactive compounds. To evaluate the potential of oleaginous plant microgreens as a source of bioactive fatty acids, gas chromatography-mass spectrometry was exploited to characterize the total fatty acid content of five microgreens, namely, chia, flax, soy, sunflower, and rapeseed (canola). Chia and flax microgreens appeared as interesting sources of α-linolenic acid (ALA), with total concentrations of 2.6 and 2.9 g/100 g of dried weight (DW), respectively. Based on these amounts, approximately 15% of the ALA daily intake recommended by the European Food Safety Authority can be provided by 100 g of the corresponding fresh products. Flow injection analysis with high-resolution Fourier transform single and tandem mass spectrometry enabled a semi-quantitative profiling of triacylglycerols (TGs) and sterol esters (SEs) in the examined microgreen crops, confirming their role as additional sources of fatty acids like ALA and linoleic acid (LA), along with glycerophospholipids. The highest amounts of TGs and SEs were observed in rapeseed and sunflower microgreens (ca. 50 and 4-5 µmol/g of DW, respectively), followed by flax (ca. 20 and 3 µmol/g DW). TG 54:9, 54:8, and 54:7 prevailed in the case of flax and chia, whereas TG 54:3, 54:4, and 54:5 were the most abundant TGs in the case of rapeseed. ß-Sitosteryl linoleate and linolenate were generally prevailing in the SE profiles, although campesteryl oleate, linoleate, and linolenate exhibited a comparable amount in the case of rapeseed microgreens.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Lipidômica , Cromatografia Gasosa-Espectrometria de Massas/métodos , Lipidômica/métodos , Lipídeos/análise , Lipídeos/química , Ácidos Graxos/análise , Ácidos Graxos/química , Linho/química , Verduras/química , Espectrometria de Massas/métodos , Triglicerídeos/análise , Triglicerídeos/química
11.
J Chromatogr A ; 1726: 464894, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38733926

RESUMO

Cyclic volatile methylsiloxanes (cVMS) have been widely found in various types of environmental media and attracted increasing attention as new pollutants. However, there is still a great challenge in the accurate quantification of trace cVMS, due to their volatility, and the high background originating from GC/MS accessories and surroundings. In this work, the main sources of the high background were investigated in detail for octamethylcyclotetrasiloxane (D4), decmethylcyclopentasiloxane (D5) and dodecmethylcyclohexosiloxane (D6). Several effective measures were employed to minimize these backgrounds, including the delayed injection method to minimize the interference from the injection septum. Then, a GC-MS method was developed for the accurate determination of D4, D5 and D6, with a linear range of 2 - 200 µg/L. The coefficient of determination was 0.9982-0.9986, the limit of detection (LOD) was 0.40-0.52 µg/L, and the quantitative range was 1.88-190 µg/L. Good reproducibility and recovery were obtained, indicating the reliability of the established analytical method.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Limite de Detecção , Siloxanas , Siloxanas/análise , Siloxanas/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Reprodutibilidade dos Testes , Volatilização , Compostos Orgânicos Voláteis/análise
12.
Metabolomics ; 20(3): 59, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773019

RESUMO

INTRODUCTION: Thyroid cancer incidence rate has increased substantially worldwide in recent years. Fine needle aspiration biopsy (FNAB) is currently the golden standard of thyroid cancer diagnosis, which however, is invasive and costly. In contrast, breath analysis is a non-invasive, safe and simple sampling method combined with a promising metabolomics approach, which is suitable for early cancer diagnosis in high volume population. OBJECTIVES: This study aims to achieve a more comprehensive and definitive exhaled breath metabolism profile in papillary thyroid cancer patients (PTCs). METHODS: We studied both end-tidal and mixed expiratory breath, solid-phase microextraction gas chromatography coupled with high resolution mass spectrometry (SPME-GC-HRMS) was used to analyze the breath samples. Multivariate combined univariate analysis was applied to identify potential breath biomarkers. RESULTS: The biomarkers identified in end-tidal and mixed expiratory breath mainly included alkanes, olefins, enols, enones, esters, aromatic compounds, and fluorine and chlorine containing organic compounds. The area under the curve (AUC) values of combined biomarkers were 0.974 (sensitivity: 96.1%, specificity: 90.2%) and 0.909 (sensitivity: 98.0%, specificity: 74.5%), respectively, for the end-tidal and mixed expiratory breath, indicating of reliability of the sampling and analysis method CONCLUSION: This work not only successfully established a standard metabolomic approach for early diagnosis of PTC, but also revealed the necessity of using both the two breath types for comprehensive analysis of the biomarkers.


Assuntos
Biomarcadores Tumorais , Testes Respiratórios , Cromatografia Gasosa-Espectrometria de Massas , Metabolômica , Microextração em Fase Sólida , Câncer Papilífero da Tireoide , Neoplasias da Glândula Tireoide , Humanos , Metabolômica/métodos , Câncer Papilífero da Tireoide/diagnóstico , Câncer Papilífero da Tireoide/metabolismo , Testes Respiratórios/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Sólida/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Biomarcadores Tumorais/análise , Biomarcadores Tumorais/metabolismo , Adulto , Neoplasias da Glândula Tireoide/diagnóstico , Neoplasias da Glândula Tireoide/metabolismo , Detecção Precoce de Câncer/métodos , Idoso
13.
Food Res Int ; 187: 114330, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38763633

RESUMO

Processing technology plays a crucial role in the formation of tea aroma. The dynamic variations in volatile metabolites across different processing stages of fresh scent green tea (FSGT) were meticulously tracked utilizing advanced analytical techniques such as GC-E-Nose, GC-MS, and GC × GC-TOFMS. A total of 244 volatile metabolites were identified by GC-MS and GC × GC-TOFMS, among which 37 volatile compounds were concurrently detected by both methods. Spreading and fixation stages were deemed as pivotal processes for shaping the volatile profiles in FSGT. Notably, linalool, heptanal, 2-pentylfuran, nonanal, ß-myrcene, hexanal, 2-heptanone, pentanal, 1-octen-3-ol, and 1-octanol were highlighted as primary contributors to the aroma profiles of FSGT by combining odor activity value assessment. Furthermore, lipid degradation and glycoside hydrolysis were the main pathways for aroma formation of FSGT. The results not only elucidate the intricate variations in volatile metabolites but also offer valuable insights into enhancing the processing techniques for improved aroma quality of green tea.


Assuntos
Manipulação de Alimentos , Cromatografia Gasosa-Espectrometria de Massas , Odorantes , Chá , Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/metabolismo , Cromatografia Gasosa-Espectrometria de Massas/métodos , Odorantes/análise , Chá/química , Manipulação de Alimentos/métodos , Nariz Eletrônico , Aldeídos/análise , Aldeídos/metabolismo , Monoterpenos Acíclicos/metabolismo , Monoterpenos Acíclicos/análise , Camellia sinensis/química , Camellia sinensis/metabolismo , Cetonas/análise , Cetonas/metabolismo , Octanóis
14.
Food Res Int ; 187: 114398, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38763656

RESUMO

Nowadays, it is important to monitor the freshness of meat during storage to protect consumers' health. Volatile organic compounds (VOCs) are responsible for odour and taste of food, and they give an indication about meat quality and freshness. This study had the aim to seek and select potential new markers of meat spoilage through a semi-quantitative analysis in five types of meat (beef, raw and baked ham, pork sausage and chicken) and then to develop a new quantitative analytical method to detect and quantify potential markers on five types of meat simultaneously. Firstly, a new headspace-solid phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) method was developed to evaluate the volatile profile of five types of meat, preserved at 4 °C for 5 days. Among the 40 compounds identified, 15 were chosen and selected as potential shelf-life markers on the basis of their presence in most of meat samples or/and for their constant increasing/decreasing trend within the sample. Afterwards, a quantitative HS-SPME-GC-MS analytical method was developed to confirm which VOCs can be considered markers of shelf-life for these meat products, stored at 4 °C for 12 days. Some of the compounds analyzed attracted attention as they can be considered markers of shelf-life for at least 4 types of meat: 1-butanol, 3-methylbutanol, 1-hexanol, 2-nonanone, nonanal, 1-octen-3-ol and linalool. In conclusion, in this study a new quantitative HS-SPME-GC-MS analytical method to quantity 15 VOCs in five types of meat was developed and it was demonstrated that some of the compounds quantified can be considered markers of shelf-life for some of the meat products analyzed.


Assuntos
Armazenamento de Alimentos , Cromatografia Gasosa-Espectrometria de Massas , Produtos da Carne , Microextração em Fase Sólida , Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Sólida/métodos , Produtos da Carne/análise , Animais , Suínos , Odorantes/análise , Bovinos , Aldeídos/análise , Galinhas , Cetonas/análise , Pentanóis/análise , Monoterpenos Acíclicos/análise , Octanóis
15.
Se Pu ; 42(5): 465-473, 2024 Apr 08.
Artigo em Chinês | MEDLINE | ID: mdl-38736390

RESUMO

A method based on gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS) coupled with one-step QuEChERS technique was developed for the simultaneous determination of 15 N-nitrosamines in air-dried yak meat. The hydration volume, extraction solvent, extracting salt, and cleaning material were optimized according to the characteristics of the N-nitrosamines and sample matrix. The optimized conditions were as follows: 10 mL of purified water for sample hydration, acetonitrile as the extraction solvent for the sample after hydration, 4.0 g of anhydrous MgSO4 and 1.0 g of NaCl as extracting salts, 500 mg of MgSO4+25 mg of C18+50 mg of PSA as cleaning materials. Favorable recoveries of the 15 N-nitrosamines were obtained when the extraction solution was incompletely dried. Thus, the final extract was dried to below 0.5 mL under a mild nitrogen stream and then redissolved to 0.5 mL with acetonitrile. After filtration, 200 µL of the sample was transferred to an autosampler vial for GC-MS/MS analysis. The 15 N-nitrosamines were determined using GC-MS/MS on a DB-HeavyWAX column (30 m×0.25 mm×0.25 µm) with an electron impact ion source in multiple-reaction monitoring (MRM) mode, and quantified using an external standard method. Under the optimized experimental conditions, the results showed that the calibration curves exhibited good linearities for the 15 N-nitrosamines, with correlation coefficients (r2) greater than 0.9990. The limits of detection (LODs) and the limits of quantification (LOQs) ranged from 0.05 to 0.20 µg/kg and from 0.10 to 0.50 µg/kg, respectively. At spiked levels of 1LOQ, 2LOQ, and 10LOQ, the average recoveries were 79.4%-102.1%, 80.6%-109.5%, and 83.0%-110.6%, respectively, and the relative standard deviations were in the range of 0.8%-16.0%. The low matrix effects of the 15 N-nitrosamines indicated the high sensitivity of the proposed method. The method was applied to detect representative commercial air-dried yak meat samples obtained using different processing techniques. Seven N-nitrosamines, including N-nitrosodimethylamine, N-nitrosodiisobutylamine, N-nitrosodibutylamine, N-methyl-N-phenylnitrous amide, N-ethyl-N-nitrosoaniline, N-nitrosopyrrolidine, and N-nitrosodiphenylamine were detected in all samples. The average contents of the seven N-nitrosamines was 0.08-20.18 µg/kg. The detection rates and average contents of the N-nitrosamines in cooked air-dried yak meat samples were higher than those in traditional raw air-dried yak meat samples. Compared with the manual QuEChERS method, the one-step QuEChERS method developed integrated the extraction and clean-up procedures into one single run, and the detection efficiency was considerably improved. The developed method is simple, rapid, highly sensitive, and insusceptible to human errors. Thus, it is useful for the determination of N-nitrosamines in air-dried yak meat and can be extended to the qualitative and quantitative analysis of N-nitrosamines in other meat products. It also provides method support and a data reference for the general determination of N-nitrosamines, which is of great significance for food safety.


Assuntos
Contaminação de Alimentos , Cromatografia Gasosa-Espectrometria de Massas , Carne , Nitrosaminas , Animais , Nitrosaminas/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Bovinos , Contaminação de Alimentos/análise , Carne/análise
16.
J Breath Res ; 18(3)2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38701772

RESUMO

The analysis of volatile organic compounds (VOCs) in exhaled air has attracted the interest of the scientific community because it provides the possibility of monitoring physiological and metabolic processes and non-invasive diagnostics of various diseases. However, this method remains underused in clinical practice as well as in research because of the lack of standardized procedures for the collection, storage and transport of breath samples, which would guarantee good reproducibility and comparability of results. The method of sampling, as well as the storage time of the breath samples in the polymer bags used for sample storage and transport, affect the composition and concentration of VOCs present in the breath samples. The aim of our study was to compare breath samples obtained using two methods with fully disposable equipment: a Haldane sampling tube intended for direct breath collection and breath samples exhaled into a transparent Tedlar bag. The second task was to monitor the stability of selected compounds of real breath samples stored in a Tedlar bag for 6 h. Gas chromatography coupled with ion mobility spectrometry (GC-IMS) implemented in the BreathSpec®device was used to analyse exhaled breath. Our results showed a significant difference in the signal intensity of some volatiles when taking a breath sample with a Haldane tube and a Tedlar bag. Due to its endogenous origin, acetone levels were significantly higher when the Haldane tube sampler was used while elevated levels of 2-propanol and unidentified VOC (designated as VOC 3) in the Tedlar bag samples likely originated from contamination of the Tedlar bags. The VOC stability study revealed compound-specific signal intensity changes of the selected VOCs with storage time in the Tedlar bags, with some volatiles showing increasing signal intensity during storage in Tedlar bags. This limits the use of Tedlar bags only for very limited time and carefully selected purpose. Our results highlight the importance of careful design and implementation of experiments and clinical protocols to obtain relevant and reliable results.


Assuntos
Testes Respiratórios , Manejo de Espécimes , Compostos Orgânicos Voláteis , Humanos , Testes Respiratórios/instrumentação , Testes Respiratórios/métodos , Compostos Orgânicos Voláteis/análise , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos , Espectrometria de Mobilidade Iônica/métodos , Espectrometria de Mobilidade Iônica/instrumentação , Masculino , Feminino , Reprodutibilidade dos Testes , Adulto , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Expiração , Pessoa de Meia-Idade , Fatores de Tempo
17.
Food Res Int ; 183: 114240, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38760119

RESUMO

Polycyclic aromatic hydrocarbons (PAHs) are carcinogenic organic pollutants found in various environments, notably aquatic ecosystems and the food chain, posing significant health risks. Traditional methods for detecting PAHs in food involve complex processes and considerable reagent usage, raising environmental concerns. This study explores eco-friendly approaches suing solid phases derived from natural sources in matrix solid phase dispersion. We aimed to develop, optimize, and validate a sample preparation technique for seafood, employing natural materials for PAH analysis. Ten natural phases were compared with a commercial reference phase. The methodology involved matrix solid phase dispersion and pressurized liquid extraction, followed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). Three solid phases (perlite, sweet manioc starch, and barley) showed superior performance in LC-MS/MS and were further evaluated with gas chromatography-tandem mass spectrometry (GC-MS/MS), confirming perlite as the most effective phase. Validation followed Brazilian regulatory guidelines and European Community Regulation 2021/808/EC. The resulting method offered advantages in cost-effectiveness, reduced environmental impact, cleaner extracts, and enhanced analytical performance compared to the reference solid phase and LC-MS/MS. Proficiency analysis confirmed method reliability, with over 50% alignment with green analytical chemistry principles. In conclusion, this study developed an environmentally sustainable sample preparation technique for seafood analysis using natural solid phases, particularly perlite, for PAH determination.


Assuntos
Contaminação de Alimentos , Cromatografia Gasosa-Espectrometria de Massas , Hidrocarbonetos Policíclicos Aromáticos , Alimentos Marinhos , Espectrometria de Massas em Tandem , Hidrocarbonetos Policíclicos Aromáticos/análise , Alimentos Marinhos/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Líquida/métodos , Contaminação de Alimentos/análise , Extração em Fase Sólida/métodos , Reprodutibilidade dos Testes , Brasil , Química Verde/métodos
18.
Sensors (Basel) ; 24(9)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38732837

RESUMO

The gut microbiota and its related metabolites differ between inflammatory bowel disease (IBD) patients and healthy controls. In this study, we compared faecal volatile organic compound (VOC) patterns of paediatric IBD patients and controls with gastrointestinal symptoms (CGIs). Additionally, we aimed to assess if baseline VOC profiles could predict treatment response in paediatric IBD patients. We collected faecal samples from a cohort of de novo therapy-naïve paediatric IBD patients and CGIs. VOCs were analysed using gas chromatography-ion mobility spectrometry (GC-IMS). Response was defined as a combination of clinical response based on disease activity scores, without requiring treatment escalation. We included 109 paediatric IBD patients and 75 CGIs, aged 4 to 17 years. Faecal VOC profiles of paediatric IBD patients were distinguishable from those of CGIs (AUC ± 95% CI, p-values: 0.71 (0.64-0.79), <0.001). This discrimination was observed in both Crohn's disease (CD) (0.75 (0.67-0.84), <0.001) and ulcerative colitis (UC) (0.67 (0.56-0.78), 0.01) patients. VOC profiles between CD and UC patients were not distinguishable (0.57 (0.45-0.69), 0.87). Baseline VOC profiles of responders did not differ from non-responders (0.70 (0.58-0.83), 0.1). In conclusion, faecal VOC profiles of paediatric IBD patients differ significantly from those of CGIs.


Assuntos
Fezes , Doenças Inflamatórias Intestinais , Espectrometria de Mobilidade Iônica , Compostos Orgânicos Voláteis , Humanos , Compostos Orgânicos Voláteis/análise , Criança , Fezes/química , Adolescente , Feminino , Masculino , Estudos de Casos e Controles , Pré-Escolar , Espectrometria de Mobilidade Iônica/métodos , Doenças Inflamatórias Intestinais/metabolismo , Doença de Crohn/metabolismo , Colite Ulcerativa/metabolismo , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microbioma Gastrointestinal/fisiologia
19.
J Physiol Pharmacol ; 75(2): 215-222, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38736268

RESUMO

The analysis of volatile organic compounds (VOCs) present in various biological samples holds immense potential for non-invasive disease diagnostics and metabolic profiling. One of the biological fluids that are suitable for use in clinical practice is urine. Given the limited quantity of VOCs in the urine headspace, it's imperative to enhance their extraction into the gaseous phase and prevent any degradation of VOCs during the thawing process. The study aimed to test several key parameters (incubation time, temperature, and thawing) that can influence urine volatilome and monitor selected VOCs for their stability. The analysis in this study was performed using a BreathSpec® (G.A.S., Dortmund, Germany) device consisting of a gas chromatograph (GC) coupled with an ion mobility spectrometer (IMS). Testing three different temperatures and incubation times yielded a low number of VOCs (9 out of 34) that exhibited statistically significant differences. However, examining three thawing conditions revealed no VOCs with statistically significant changes. Thus, we conclude that urine composition remains relatively stable despite exposure to various thermal stresses.


Assuntos
Espectrometria de Mobilidade Iônica , Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/urina , Compostos Orgânicos Voláteis/análise , Humanos , Projetos Piloto , Espectrometria de Mobilidade Iônica/métodos , Masculino , Adulto , Cromatografia Gasosa-Espectrometria de Massas/métodos , Feminino , Temperatura , Adulto Jovem , Pessoa de Meia-Idade
20.
Chirality ; 36(5): e23676, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38736271

RESUMO

Among different substance classes, New Psychoactive Substances (NPS) comprise chiral amphetamines for stimulant and empathic effects. There is little knowledge in terms of clinical studies about possibly different effects of the two enantiomers of novel amphetamine derivatives. For this reason, there is a big demand for enantioseparation method development of this new substance class. Regarding gas chromatography, cyclodextrins proved to be effective for enantioseparation of NPS. In our attempt, an Astec® Chiraldex™ G-PN column containing 2,6-di-O-pentyl-3-propionyl-γ-cyclodextrin and a Lipodex™ D column containing heptakis-(2,6-di-O-pentyl-O-acetyl)-ß-cyclodextrin as chiral selector served as stationary phases in a Shimadzu GCMS-QP2010 SE system. Because of the special coating, maximum temperature is limited to 200 °C isothermal or 220 °C in programmed mode. To ensure detection, trifluoroacetic anhydride (TFAA) was used to increase sample volatility.1 As a result, 35 amphetamines were tested as their TFAA-derivatives. A screening method with a temperature gradient from 140 °C to 200 °C at a heating ramp of 1 °C per minute and final time of 5 min, showed baseline separation for seven and partial separations for 16 trifluoro acetylated amphetamines using the Chiraldex™ G-PN column. Six baseline and nine partial separations were observed with the Lipodex™ D column, respectively.


Assuntos
Anfetaminas , Estereoisomerismo , Anfetaminas/química , Anfetaminas/isolamento & purificação , Cromatografia Gasosa/métodos , Ciclodextrinas/química , Temperatura , Cromatografia Gasosa-Espectrometria de Massas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA