Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 781
Filtrar
1.
Ultrasound Q ; 40(4)2024 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-39282951

RESUMO

ABSTRACT: We aimed to measure cerebral, splanchnic, and renal transit times and the associated blood volumes using contrast ultrasound. In healthy individuals, regional transit times were calculated from time-intensity curves generated as ultrasound contrast passed through the associated inflow and outflow vessels. These included the internal carotid artery and internal jugular vein (brain), the superior mesenteric artery and portal vein (intestines), and the renal artery and renal vein (kidney). An organ's blood volume relative to the stroke volume delivered to that organ with each cardiac cycle was calculated from the product of heart rate and transit time of contrast passage through the associated vascular bed. The fraction of systemic stroke volume received by each organ was calculated from the respective velocity-time integral and inflow vessel cross-sectional area and used to estimate absolute organ blood volume. The cohort consisted of 16 participants (age: 42 ± 13 years; 5 female) without known cerebrovascular, gastrointestinal, or renal disease. Cerebral, splanchnic, and renal transit times were obtained for 15, 14, and 8 individuals, respectively. Anatomic variability of the renal vessels confounded the acquisition of renal transit times. For all organs, transit times were reproducible and the associated blood volumes were generally comparable to reference values. Cerebral, gastrointestinal, and renal transit times/blood volumes can be reasonably acquired from contrast ultrasound, although the latter is less reliably available. Assessment of the impact on regional blood volumes of pharmacologic or other interventions is a next step toward clinical application of this technique.


Assuntos
Volume Sanguíneo , Meios de Contraste , Circulação Esplâncnica , Ultrassonografia , Humanos , Feminino , Masculino , Adulto , Ultrassonografia/métodos , Volume Sanguíneo/fisiologia , Circulação Esplâncnica/fisiologia , Rim/diagnóstico por imagem , Rim/irrigação sanguínea , Circulação Cerebrovascular/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Aumento da Imagem/métodos , Determinação do Volume Sanguíneo/métodos , Circulação Renal/fisiologia
2.
Ren Fail ; 46(2): 2377781, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39148318

RESUMO

Background: Management of body fluid volumes and adequate prescription of ultrafiltration (UF) remain key issues in the treatment of chronic kidney disease patients.Objective: This study aims to estimate the magnitude as well as the precision of absolute blood volume (Vb) modeled during regular hemodialysis (HD) using standard data available with modern dialysis machines.Methods: The estimation utilizes a two-compartment fluid model and a mathematical optimization technique to predict UF-induced changes in hematocrit measured by available on-line techniques. The method does not rely on a specific hematocrit sensor or a specific UF or volume infusion protocol and uses modeling and prediction tools to quantify the error in Vb estimation.Results: The method was applied to 21 treatments (pre-UF body mass: 65.57±13.44 kg, UF-volume: 3.99±1.14 L) obtained in ten patients (4 female). Pre-HD Vb was 5.4±0.53 L with an average coefficient of variation of 9.8% (range 1 to 22%). A significant moderate correlation was obtained when Vb was compared to a different method applied to the same data set (r = 0.5). Specific blood volumes remained above the critical level of 65 mL/kg in 17 treatments (80.9%).Conclusion: The method offers the opportunity to detect critical blood volumes during HD and to judge the quality and reliability of that information based on the precision of the Vb estimate.


Assuntos
Volume Sanguíneo , Diálise Renal , Humanos , Feminino , Diálise Renal/métodos , Masculino , Pessoa de Meia-Idade , Idoso , Hematócrito , Falência Renal Crônica/terapia , Determinação do Volume Sanguíneo/métodos , Adulto , Insuficiência Renal Crônica/terapia , Insuficiência Renal Crônica/sangue
3.
Cardiorenal Med ; 14(1): 483-497, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39033745

RESUMO

BACKGROUND: This review delves into the intricate landscape of cardiorenal syndrome (CRS) and highlights the pivotal role of blood volume analysis (BVA) in improving patient care and outcomes. SUMMARY: BVA offers a direct and highly accurate quantification of intravascular volume, red blood cell volume, and plasma volume, complete with patient-specific norms. This diagnostic tool enhances the precision of diuretic and red cell therapies, significantly elevating the effectiveness of conventional care. KEY MESSAGES: Our objectives encompass a comprehensive understanding of how BVA informs the evaluation and treatment of CRS, including its subtypes, pathophysiology, and clinical significance. We delve into BVA principles, techniques, and measurements, elucidating its diagnostic potential and advantages compared to commonly used surrogate measures. We dissect the clinical relevance of BVA in various CRS scenarios, emphasizing its unique contributions to each subtype. By assessing the tangible impact of BVA on patient outcomes through meticulous analysis of relevant clinical studies, we unveil its potential to enhance health outcomes and optimize resource utilization. Acknowledging the challenges and limitations associated with BVA's clinical implementation, we underscore the importance of multidisciplinary collaboration among cardiologists, nephrologists, and other clinicians. Finally, we identify research gaps and propose future directions for BVA and CRS, contributing to ongoing advancements in this field and patients affected by this complicated clinical syndrome.


Assuntos
Determinação do Volume Sanguíneo , Volume Sanguíneo , Síndrome Cardiorrenal , Humanos , Síndrome Cardiorrenal/fisiopatologia , Síndrome Cardiorrenal/classificação , Síndrome Cardiorrenal/terapia , Volume Sanguíneo/fisiologia , Determinação do Volume Sanguíneo/métodos
4.
Eur Rev Med Pharmacol Sci ; 28(11): 3702-3710, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38884505

RESUMO

OBJECTIVE: Monitoring Jackson Pratt and Hemovac drains plays a crucial role in assessing a patient's recovery and identifying potential postoperative complications. Accurate and regular monitoring of the blood volume in the drain is essential for making decisions about patient care. However, transferring blood to a measuring cup and recording it is a challenging task for both patients and doctors, exposing them to bloodborne pathogens such as the human immunodeficiency virus (HIV), hepatitis B virus (HBV), and hepatitis C virus (HCV). To automate the recording process with a non-contact approach, we propose an innovative approach that utilizes deep learning techniques to detect a drain in a photograph, compute the blood level in the drain, estimate the blood volume, and display the results on both web and mobile interfaces. MATERIALS AND METHODS: Our system employs semantic segmentation on images taken with mobile phones to effectively isolate the blood-filled portion of the drain from the rest of the image and compute the blood volume. These results are then sent to mobile and web applications for convenient access. To validate the accuracy and effectiveness of our system, we collected the Drain Dataset, which consists of 1,004 images taken under various background and lighting conditions. RESULTS: With an average error rate of less than 5% in milliliters, our proposed approach achieves highly accurate blood level detection and estimation, as demonstrated by our trials on this dataset. The system also exhibits robustness to variations in lighting conditions and drain shapes, ensuring its applicability in different clinical scenarios. CONCLUSIONS: The proposed automated blood volume estimation system can significantly reduce the time and effort required for manual measurements, enabling healthcare professionals to focus on other critical tasks. The dataset and annotations are available at: https://www.kaggle.com/datasets/ayenahin/liquid-volume-detection-from-drain-images and the code for the web application is available at https://github.com/itsjustaplant/AwesomeProject.git.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Drenagem , Humanos , Drenagem/métodos , Volume Sanguíneo , Aprendizado Profundo , Determinação do Volume Sanguíneo/métodos
5.
Am Heart J ; 271: 178-181, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38658075

RESUMO

The prognostic implications of intravascular volume status assessed by blood volume analysis (BVA) in ambulatory heart failure (HF) remain uncertain. The incremental benefits of assessing volume status, beyond the well-established filling pressures, in predicting HF outcomes are unknown.


Assuntos
Volume Sanguíneo , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/diagnóstico , Prognóstico , Volume Sanguíneo/fisiologia , Volume Sistólico/fisiologia , Masculino , Feminino , Determinação do Volume Sanguíneo/métodos , Idoso , Pessoa de Meia-Idade
6.
J Nephrol ; 37(4): 897-909, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38530603

RESUMO

BACKGROUND: Despite the improvements in hemodialysis (HD) technology, 20-30% of sessions are still complicated by hypotension or hypotension-related symptoms. Biofeedback systems have proven to reduce the occurrence of such events, but no conclusive findings can lead to wider adoption of these systems. We conducted this systematic review and meta-analysis of randomized clinical trials to establish whether the use of blood volume tracking systems compared to conventional hemodialysis (C-HD) reduces the occurrence of intradialytic hypotension. METHODS: The PRISMA guidelines were used to carry out this systematic review. Randomized clinical trials that evaluated the incidence of intradialytic hypotension during C-HD and blood volume tracking-HD were searched in the current literature. PROSPERO registration number: CRD42023426328. RESULTS: Ninety-seven randomized clinical trials were retrieved. Nine studies, including 347 participants and 13,274 HD treatments were considered eligible for this systematic review. The results showed that the use of biofeedback systems reduces the risk of intradialytic hypotension (log odds ratio = 0.63, p = 0.03) in hypotension-prone patients (log odds ratio = 0.54, p = 0.04). When analysis was limited to fluid overloaded or hypertensive patients, it did not show the same effect (log odds ratio = 0.79, p = 0.38). No correlation was found in systolic blood pressure drop during dialysis and in post-dialysis blood pressure. CONCLUSIONS: The use of blood volume tracking systems may be effective in reducing the incidence of intradialytic hypotension and allowing for easier attainment of the patients' ideal dry body weight. New studies to examine the long-term effects of the use of blood volume tracking systems on real hard endpoints are needed.


Assuntos
Biorretroalimentação Psicológica , Pressão Sanguínea , Volume Sanguíneo , Hipotensão , Ensaios Clínicos Controlados Aleatórios como Assunto , Diálise Renal , Humanos , Diálise Renal/efeitos adversos , Hipotensão/prevenção & controle , Hipotensão/etiologia , Biorretroalimentação Psicológica/métodos , Resultado do Tratamento , Fatores de Risco , Determinação do Volume Sanguíneo/métodos
7.
Aust Crit Care ; 37(4): 632-637, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38245397

RESUMO

BACKGROUND: Continuous haemoglobin, venous blood oxygen saturation, and haematocrit (Hct) monitoring is currently not applied during continuous renal replacement therapy (CRRT). Such Hct monitoring enables estimation of changes in blood volume as percentage change (ΔBV%) from therapy start time and is incorporated into intermittent haemodialysis machines but not CRRT machines despite its potential to optimise fluid management in CRRT patients. METHODS: To overcome this problem, we used a standalone monitor (CRIT-LINE®IV, Fresenius Medical Care, Concord, USA) with an associated in-line blood chamber (CRIT-LINE®IV Blood Chamber, Fresenius Medical Care, Concord, USA) and designed our own adaptor connection piece (TekMed and Morriset, Melbourne and Brisbane, Australia) to allow these readings at the vascular access outflow and recorded data for estimated Hct and derived ΔBV% during CRRT. RESULTS: We report on this technique with an illustrative case example and 12 h of CRRT data on the fluid loss rate prescribed, hourly net patient fluid loss (range: 0-308 mL/h), mean arterial pressure, norepinephrine dose (range: 5-14 mcg/min), estimated continuous Hct and ΔBV%, and the otherwise undetected diagnosis of an approximate 15 % decrease in blood volume during the CRRT. CONCLUSION: We have described a technical CRRT circuit modification that can facilitate a previously unavailable assessment of fluid shifts during CRRT. Further application in clinical trials is now possible.


Assuntos
Volume Sanguíneo , Terapia de Substituição Renal Contínua , Humanos , Terapia de Substituição Renal Contínua/métodos , Hematócrito , Monitorização Fisiológica/métodos , Determinação do Volume Sanguíneo/métodos , Masculino , Injúria Renal Aguda/terapia , Injúria Renal Aguda/sangue
8.
Sci Rep ; 11(1): 12201, 2021 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-34108583

RESUMO

Acute normovolemic hemodilution (ANH) is a potential transfusion method for platelets, as well as for red blood cells. However, previous studies have shown that whole blood storage in ANH decreases platelet aggregability by 14.7-76.3% and that this decrease is not recovered by reinfusion. We investigated whether a new whole blood storage method for 6 h using a polyolefin bag, based on the platelet concentrates storage method, would maintain platelet function better than the conventional method using a polyvinyl chloride bag. We demonstrated that storage of whole blood in a polyolefin bag maintained ADP-induced aggregation rates at more than twofold higher than those in a polyvinyl chloride bag, and also significantly suppressed P-selectin expression, a platelet activation marker (ADP-induced aggregation rates: 24.6 ± 5.1% vs. 51.7 ± 11.5%, p = 0.002; P-selectin expression; 50.3 ± 8.4MFI vs. 31.6 ± 9.3MFI, p = 0.018). These results could be attributed to the high gas permeability of polyolefin, which lowered PCO2 and maintained a high pH with or without agitation. There were no significant changes in platelet count and red blood cell parameters due to the storage methods. Our results suggest that ANH using polyolefin bags is advantageous in improving hemostatic function compared to the conventional method.


Assuntos
Plaquetas/fisiologia , Preservação de Sangue/instrumentação , Preservação de Sangue/métodos , Determinação do Volume Sanguíneo/métodos , Hemodiluição/métodos , Hemostasia , Polienos/química , Hemodiluição/estatística & dados numéricos , Humanos , Ativação Plaquetária , Agregação Plaquetária , Testes de Função Plaquetária
9.
Int J Artif Organs ; 44(4): 282-287, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32921219

RESUMO

The spleen serves as a blood volume reservoir for systemic volume regulation in heart failure (HF) patients. Changes are seen in spleen size in advanced HF patients after left ventricular assist device (LVAD) implantation. The pulsatility index (PI) is an indicator of native heart contractility with hemodynamic changes in patients using LVAD. We hypothesized that the splenic volume was associated with the PI, reflecting the hemodynamics in advanced HF patients with LVADs. Herein, we investigated the relationship between splenic volume and PI in these patients. Forty-four patients with advanced HF underwent implantation of HeartMate II® (Abbott, Chicago, IL, USA) as a bridge to heart transplantation at the Nagoya University Hospital between October 2013 and June 2019. The data of 27 patients (21 men, median age 46 years) were analyzed retrospectively. All patients underwent blood tests, echocardiography, right heart catheterization, and computed tomography (CT). Spleen size was measured via CT volumetry; the splenic volume (median: 190 mL) correlated with right arterial pressure (r = 0.431, p = 0.025) and pulmonary capillary wedge pressure (r = 0.384, p = 0.048). On multivariate linear regression analysis, the heart rate (ß = -0.452, p = 0.003), pump power (ß = -0.325, p = 0.023), and splenic volume (ß = 0.299, p = 0.038) were independent determinants of PI. The splenic volume was associated with PI, reflecting the cardiac preload in advanced HF patients with LVADs. Thus, spleen measurement using CT may help estimate the systemic volume status and understand the hemodynamic conditions in LVAD patients.


Assuntos
Circulação Assistida , Determinação do Volume Sanguíneo/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Insuficiência Cardíaca , Coração Auxiliar , Baço , Circulação Assistida/instrumentação , Circulação Assistida/métodos , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Fluxo Pulsátil , Estudos Retrospectivos , Índice de Gravidade de Doença , Baço/patologia , Baço/fisiopatologia
10.
Theranostics ; 10(18): 8143-8161, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32724463

RESUMO

Neuroblastoma (NB) is the most common extracranial solid tumor in infants and children, and imposes significant morbidity and mortality in this population. The aggressive chemoradiotherapy required to treat high-risk NB results in survival of less than 50%, yet is associated with significant long-term adverse effects in survivors. Boosting efficacy and reducing morbidity are therefore key goals of treatment for affected children. We hypothesize that these may be achieved by developing strategies that both focus and limit toxic therapies to the region of the tumor. One such strategy is the use of targeted image-guided drug delivery (IGDD), which is growing in popularity in personalized therapy to simultaneously improve on-target drug deposition and assess drug pharmacodynamics in individual patients. IGDD strategies can utilize a variety of imaging modalities and methods of actively targeting pharmaceutical drugs, however in vivo imaging in combination with focused ultrasound is one of the most promising approaches already being deployed for clinical applications. Over the last two decades, IGDD using focused ultrasound with "microbubble" ultrasound contrast agents (UCAs) has been increasingly explored as a method of targeting a wide variety of diseases, including cancer. This technique, known as sonopermeation, mechanically augments vascular permeability, enabling increased penetration of drugs into target tissue. However, to date, methods of monitoring the vascular bioeffects of sonopermeation in vivo are lacking. UCAs are excellent vascular probes in contrast-enhanced ultrasound (CEUS) imaging, and are thus uniquely suited for monitoring the effects of sonopermeation in tumors. Methods: To monitor the therapeutic efficacy of sonopermeation in vivo, we developed a novel system using 2D and 3D quantitative contrast-enhanced ultrasound imaging (qCEUS). 3D tumor volume and contrast enhancement was used to evaluate changes in blood volume during sonopermeation. 2D qCEUS-derived time-intensity curves (TICs) were used to assess reperfusion rates following sonopermeation therapy. Intratumoral doxorubicin (and liposome) uptake in NB was evalauted ex vivo along with associated vascular changes. Results: In this study, we demonstrate that combining focused ultrasound therapy with UCAs can significantly enhance chemotherapeutic payload to NB in an orthotopic xenograft model, by improving delivery and tumoral uptake of long-circulating liposomal doxorubicin (L-DOX) nanoparticles. qCEUS imaging suggests that changes in flow rates are highly sensitive to sonopermeation and could be used to monitor the efficacy of treatment in vivo. Additionally, initial tumor perfusion may be a good predictor of drug uptake during sonopermeation. Following sonopermeation treatment, vascular biomarkers show increased permeability due to reduced pericyte coverage and rapid onset of doxorubicin-induced apoptosis of NB cells but without damage to blood vessels. Conclusion: Our results suggest that significant L-DOX uptake can occur by increasing tumor vascular permeability with microbubble sonopermeation without otherwise damaging the vasculature, as confirmed by in vivo qCEUS imaging and ex vivo analysis. The use of qCEUS imaging to monitor sonopermeation efficiency and predict drug uptake could potentially provide real-time feedback to clinicians for determining treatment efficacy in tumors, leading to better and more efficient personalized therapies. Finally, we demonstrate how the IGDD strategy outlined in this study could be implemented in human patients using a single case study.


Assuntos
Doxorrubicina/análogos & derivados , Microbolhas , Neuroblastoma/tratamento farmacológico , Imagem de Perfusão/métodos , Ultrassonografia de Intervenção/métodos , Animais , Apoptose/efeitos dos fármacos , Determinação do Volume Sanguíneo/instrumentação , Determinação do Volume Sanguíneo/métodos , Permeabilidade Capilar/efeitos da radiação , Linhagem Celular Tumoral , Meios de Contraste/administração & dosagem , Doxorrubicina/administração & dosagem , Doxorrubicina/farmacocinética , Sistemas de Liberação de Medicamentos/métodos , Estudos de Viabilidade , Humanos , Camundongos , Neuroblastoma/irrigação sanguínea , Neuroblastoma/diagnóstico por imagem , Técnicas Fotoacústicas/instrumentação , Técnicas Fotoacústicas/métodos , Polietilenoglicóis/administração & dosagem , Polietilenoglicóis/farmacocinética , Estudos de Caso Único como Assunto , Ondas Ultrassônicas , Ultrassonografia de Intervenção/instrumentação , Ensaios Antitumorais Modelo de Xenoenxerto
11.
Ann Hematol ; 99(9): 2047-2055, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32691114

RESUMO

Manual erythroexchange (MEEX) was proven to be effective and safe in the management of sickle cell disease (SCD). The goal is to quickly reduce the percentage of hemoglobin S (HbS%). A national survey of the Italian Society for Thalassemia and Hemoglobinopathies (SITE) observed a great variability among MEEX protocols none of which were found to be predictive of the values of HbS% and hemoglobin (Hb) after the exchange. Two equations to estimate the HbS% and Hb values to be obtained after MEEX were developed based on the results of the MEEX procedures in place in the centers participating in the present study. A standard protocol was subsequently defined to evaluate the volumes to exchange to obtain the target values of HbS% and Hb. The protocol was tested in 261 MEEX performed in SCD patients followed in the 5 participating centers that belong to the Italian Hemoglobinopathy Comprehensive Care Network, with the support of the SITE. The results showed a correlation between the estimated and measured values of HbS% and Hb (Rp 0.95 and 0.65 respectively, p < 0.001). A negligible bias was found for the prediction of HbS% and a bias of 1 g/dl for Hb. From consecutive MEEX, a rate of increase of HbS% between two exchanges of around 0.4% per day (p < 0.001) was measured. This protocol was shown to be effective and safe, as all patients reached the target value of HbS%. All the MEEX procedures were carried out with single venous access. No adverse events or reactions such as hypotension or electrolyte imbalance were reported nor were any complaints concerning the procedures received from patients.


Assuntos
Anemia Falciforme/sangue , Anemia Falciforme/terapia , Determinação do Volume Sanguíneo/normas , Volume Sanguíneo/fisiologia , Transfusão de Eritrócitos/normas , Hemoglobina Falciforme/metabolismo , Adulto , Anemia Falciforme/epidemiologia , Determinação do Volume Sanguíneo/métodos , Transfusão de Eritrócitos/métodos , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
12.
Bioelectromagnetics ; 41(1): 21-33, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31755122

RESUMO

The present study is part of an ongoing effort to develop a simple diagnostic technology for detecting internal bleeding in the brain, which can be used in lieu or in support of medical imaging and thereby reduce the cost of diagnostics in general, and in particular, would make diagnostics accessible to economically disadvantaged populations. The study deals with a single coil inductive device to be used for detecting cerebral hemorrhage. It presents a first-order experimental study that examines the predictions of our recently published theoretical study. The experimental model employs a homogeneous cylindrical phantom in which internal head bleeding was simulated by way of a fluid inclusion. We measured the changes in amplitude and phase across the coil with a network vector analyzer as a function of frequency (100-1,000 MHz), volume of blood simulating fluid, and the site of the fluid injection. We have developed a new mathematical model to statistically analyze the complex data produced in this experiment. We determined that the resolution for the fluid volume increase following fluid injection is strongly dependent on frequency as well as the location of liquid accumulation. The experimental data obtained in this study supports the predictions of our previous theoretical study, and the statistical analysis shows that the simple single coil device is sensitive enough to detect changes due to fluid volume alteration of two milliliters. Bioelectromagnetics. 2020;41:21-33 © 2019 Bioelectromagnetics Society.


Assuntos
Determinação do Volume Sanguíneo/métodos , Simulação por Computador , Imagens de Fantasmas , Acidente Vascular Cerebral/diagnóstico , Volume Sanguíneo , Condutividade Elétrica , Campos Eletromagnéticos , Desenho de Equipamento , Transdutores
13.
Ther Apher Dial ; 24(3): 333-342, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31437359

RESUMO

Apheresis in low body weight children and adolescents is challenging due to a variety of technical and clinical issues including vascular access, low total blood volume, and hypotension. Although dogs have been a valuable preclinical model for apheresis, the procedure can be challenging since many pure-bred dogs are extremely small. Therefore, apheresis in these very small breeds presents very similar challenges as seen when performing the procedure in very low body weight people. We describe apheresis of four very small dogs, weighing from 4.6 to 7.6 kg, using either a COBESpectra and Spectra Optia apheresis system (Terumo BCT, Lakewood, CO, USA). Two dogs underwent large volume leukapheresis to collect mononuclear cells in preparation for hematopoietic stem cell transplantation and two dogs underwent therapeutic plasma exchange to treat an immune-mediated disease. In all cases, a dual-lumen hemodialysis catheter placed in the jugular vein provided adequate machine inlet and return flow rates. Machine priming was necessary to maintain hemodynamic stability during the beginning of the procedure, and rinseback was avoided for the same reason. Anticoagulant citrate dextrose solution, solution A was used for the large volume leukapheresis procedures and a combination of anticoagulant citrate dextrose solution, solution A and heparin was used for the therapeutic plasma exchange procedures. As such, serum iCa levels were regularly monitored and 10% calcium gluconate constant rate infusions were used to prevent citrate toxicity. All dogs completed the aphereses with no life-threatening adverse events. We conclude that aphereses in very small dogs is feasible if close attention is paid to hemodynamic stability and citrate toxicity.


Assuntos
Remoção de Componentes Sanguíneos , Tamanho Corporal/fisiologia , Transplante de Células-Tronco Hematopoéticas/métodos , Hipotensão , Leucaférese , Troca Plasmática/métodos , Magreza , Animais , Remoção de Componentes Sanguíneos/efeitos adversos , Remoção de Componentes Sanguíneos/métodos , Determinação do Volume Sanguíneo/métodos , Peso Corporal/fisiologia , Cães , Hipotensão/etiologia , Hipotensão/fisiopatologia , Hipotensão/prevenção & controle , Leucaférese/instrumentação , Leucaférese/métodos , Modelos Animais , Magreza/diagnóstico , Magreza/fisiopatologia , Resultado do Tratamento
14.
AJNR Am J Neuroradiol ; 40(9): 1445-1450, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31371360

RESUMO

BACKGROUND AND PURPOSE: The percentage signal recovery in non-leakage-corrected (no preload, high flip angle, intermediate TE) DSC-MR imaging is known to differ significantly for glioblastoma, metastasis, and primary CNS lymphoma. Because the percentage signal recovery is influenced by preload and pulse sequence parameters, we investigated whether the percentage signal recovery can still differentiate these common contrast-enhancing neoplasms using a DSC-MR imaging protocol designed for relative CBV accuracy (preload, intermediate flip angle, low TE). MATERIALS AND METHODS: We retrospectively analyzed DSC-MR imaging of treatment-naïve, pathology-proved glioblastomas (n = 14), primary central nervous system lymphomas (n = 7), metastases (n = 20), and meningiomas (n = 13) using a protocol designed for relative CBV accuracy (a one-quarter-dose preload and single-dose bolus of gadobutrol, TR/TE = 1290/40 ms, flip angle = 60° at 1.5T). Mean percentage signal recovery, relative CBV, and normalized baseline signal intensity were compared within contrast-enhancing lesion volumes. Classification accuracy was determined by receiver operating characteristic analysis. RESULTS: Relative CBV best differentiated meningioma from glioblastoma and from metastasis with areas under the curve of 0.84 and 0.82, respectively. The percentage signal recovery best differentiated primary central nervous system lymphoma from metastasis with an area under the curve of 0.81. Relative CBV and percentage signal recovery were similar in differentiating primary central nervous system lymphoma from glioblastoma and from meningioma. Although neither relative CBV nor percentage signal recovery differentiated glioblastoma from metastasis, mean normalized baseline signal intensity achieved 86% sensitivity and 50% specificity. CONCLUSIONS: Similar to results for non-preload-based DSC-MR imaging, percentage signal recovery for one-quarter-dose preload-based, intermediate flip angle DSC-MR imaging differentiates most pair-wise comparisons of glioblastoma, metastasis, primary central nervous system lymphoma, and meningioma, except for glioblastoma versus metastasis. Differences in normalized post-preload baseline signal for glioblastoma and metastasis, reflecting a snapshot of dynamic contrast enhancement, may motivate the use of single-dose multiecho protocols permitting simultaneous quantification of DSC-MR imaging and dynamic contrast-enhanced MR imaging parameters.


Assuntos
Determinação do Volume Sanguíneo/métodos , Volume Sanguíneo , Neoplasias Encefálicas/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Glioblastoma/diagnóstico por imagem , Linfoma/diagnóstico por imagem , Meningioma/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade
15.
PLoS One ; 14(8): e0220764, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31404089

RESUMO

BACKGROUND: Relative blood volume (RBV) changes during hemodialysis (HD) are typically estimated based on online measurements of hematocrit, hemoglobin or total blood protein. The aim of this study was to assess changes in the above parameters during HD in order to compare the potential differences in the RBV changes estimated by individual methods. METHODS: 25 anuric maintenance HD patients were monitored during a 1-week conventional HD treatment. Blood samples were collected from the arterial dialysis blood line at the beginning and at the end of each HD session. The analysis of blood samples was performed using the hematology analyzer Advia 2120 and clinical chemistry analyzer Advia 1800 (Siemens Healthcare). RESULTS: During the analyzed 30 HD sessions with ultrafiltration in the range 0.7-4.0 L (2.5 ± 0.8 L) hematocrit (HCT) increased by 9.1 ± 7.0% (mean ± SD), hemoglobin (HGB) increased by 10.6 ± 6.3%, total plasma protein (TPP) increased by 15.6 ± 9.5%, total blood protein (TBP) increased by 10.4 ± 5.8%, red blood cell count (RBC) increased by 10.8 ± 7.1%, while mean corpuscular red cell volume (MCV) decreased by 1.5 ± 1.1% (all changes statistically significant, p < 0.001). HGB increased on average by 1.5% more than HCT (p < 0.001). The difference between HGB and TBP increase was insignificant (p = 0.16). CONCLUSIONS: Tracking HGB or TBP can be treated as equivalent for the purpose of estimating RBV changes during HD. Due to the reduction of MCV, the HCT-based estimate of RBV changes may underestimate the actual blood volume changes.


Assuntos
Proteínas Sanguíneas/análise , Determinação do Volume Sanguíneo , Hematócrito , Hemoglobinas/análise , Diálise Renal , Adulto , Idoso , Volume Sanguíneo , Determinação do Volume Sanguíneo/métodos , Feminino , Humanos , Falência Renal Crônica/sangue , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade
16.
Eur Radiol Exp ; 3(1): 21, 2019 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-31144237

RESUMO

We report on the feasibility of C-arm cone-beam computed tomography (CBCT) parenchymal blood volume imaging (PBVI) performed immediately following transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC) to assess the need for repeat treatment. Eighteen TACE procedures were included. A retrospective assessment was made for the presence or absence of residual disease requiring treatment on immediate post-TACE PBVI and on interval follow-up multidetector computed tomography (MDCT) or magnetic resonance imaging (MRI). In 9/18 cases, both PBVI and MDCT/MRI showed that no further treatment was required. In 6/18 cases, further treatment was required on both PBVI and MDCT/MRI. In three cases, PBVI showed that further treatment was not required but MDCT/MRI showed residual disease requiring repeat treatment. There were no cases with PBVI showing residual disease not detected on follow-up MDCT/MRI. The PBVI sensitivity for detecting disease requiring repeat TACE was 67% (95% confidence interval [CI] 30-93%), and specificity was 100% (95% CI 66-100%). The use of C-arm CBCT PBVI for the detection of residual viable tumor within a treated lesion immediately after TACE is feasible. It may allow repeat TACE to be planned without performing interval imaging with MDCT or MRI.


Assuntos
Determinação do Volume Sanguíneo/métodos , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico , Neoplasias Hepáticas/terapia , Adulto , Idoso , Artérias , Carcinoma Hepatocelular/fisiopatologia , Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Estudos de Viabilidade , Feminino , Humanos , Neoplasias Hepáticas/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Planejamento de Assistência ao Paciente , Estudos Retrospectivos , Resultado do Tratamento
17.
Sensors (Basel) ; 19(4)2019 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-30769957

RESUMO

Photoplethysmography (PPG) is a non-invasive photometric technique that measures the volume changes in arterial blood. Recent studies have reported limitations in developing and optimising PPG-based sensing technologies due to unavailability of the fundamental information such as PPG-pathlength and penetration depth in a certain region of interest (ROI) in the human body. In this paper, a robust computational model of a dual wavelength PPG system was developed using Monte Carlo technique. A three-dimensional heterogeneous volume of a specific ROI (i.e., human finger) was exposed at the red (660 nm) and infrared (940 nm) wavelengths in the reflectance and transmittance modalities of PPG. The optical interactions with the individual pulsatile and non-pulsatile tissue-components were demonstrated and the optical parameters (e.g., pathlength, penetration depth, absorbance, reflectance and transmittance) were investigated. Results optimised the source-detector separation for a reflectance finger-PPG sensor. The analysis with the recorded absorbance, reflectance and transmittance confirmed the maximum and minimum impact of the dermis and bone tissue-layers, respectively, in the formation of a PPG signal. The results presented in the paper provide the necessary information to develop PPG-based transcutaneous sensors and to understand the origin of the ac and dc components of the PPG signal.


Assuntos
Determinação do Volume Sanguíneo/métodos , Simulação por Computador , Oximetria/métodos , Fotopletismografia/métodos , Dedos/fisiologia , Humanos , Método de Monte Carlo , Oxigênio/metabolismo , Processamento de Sinais Assistido por Computador
18.
Eur Radiol ; 29(9): 5022-5031, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30788587

RESUMO

PURPOSE: To determine whether intraprocedural C-arm cone-beam CT (CBCT) parenchymal blood volume (PBV) can predict the response of colorectal cancer liver metastases (CRCLM) 2 months after irinotecan drug-eluting bead (DEBIRI) chemoembolization. MATERIALS AND METHODS: This single-center observational study was compliant with the Helsinki Declaration and approved by our institutional review board. Thirty-four consecutive CRCLM patients referred for DEBIRI chemoembolization were enrolled between March 2015 and December 2016. Tumor size was assessed at baseline and 2 months after DEBIRI chemoembolization by multidetector CT (Response Evaluation Criteria in Solid Tumors RECIST 1.0), and PBV was measured before and after DEBIRI chemoembolization. Two independent readers reviewed all data. We determined the potential correlation (Spearman's rank correlation) between intraprocedural PBV values and tumor response at 2 months. The relationship between tumor response and PBV was studied using a mixed model. A logistic regression model was applied to study the relationship between patient "Responder/Non-responder" and PBV. RESULTS: There was a strong correlation between baseline PBV or the percent change of PBV and the 2-month tumor response (rho = - 0.8587 (p = 0.00001) and rho = 0.8027 (p = 0.00001), respectively). The mixed model showed that an increase of 1 ml/1000 ml in PBV of a tumor before DEBIRI chemoembolization led to a 0.54 mm decrease in diameter (p < 0.005). A 1% decrease in PBV after DEBIRI chemoembolization resulted in tumor shrinkage of 0.75 mm (p < 0.005). The logistic regression model showed that patients with a 1% smaller mean decrease of PBV after DEBIRI chemoembolization had a 10% lower likelihood of achieving disease control (OR = 0.9, 95% confidence interval (CI) = 0.81-1; p = 0.0493). CONCLUSION: Intraprocedural PBV may predict tumor response to DEBIRI chemoembolization. KEY POINTS: • There is a strong relationship between the parenchymal blood volume (PBV) of colorectal liver metastases before DEBIRI chemoembolization and tumor response at 2 months. • Higher PBV values before DEBIRI chemoembolization correlate with greater tumor shrinkage, but only if the PBV decreases by more than 70% after DEBIRI chemoembolization. • Each increase of 1% in the mean decrease of PBV after DEBIRI chemoembolization resulted in a 10% lower likelihood of achieving disease control (OR = 0.9, 95% confidence interval (CI) = 0.81-1; p = 0.0493).


Assuntos
Determinação do Volume Sanguíneo/métodos , Volume Sanguíneo/fisiologia , Quimioembolização Terapêutica/métodos , Neoplasias Colorretais/secundário , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Hepáticas/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/terapia , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
20.
J Pediatric Infect Dis Soc ; 8(2): 166-169, 2019 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-30010914

RESUMO

In this quasi-experimental study that included 3489 blood culture bottles, interventions that included the distribution of simple weight-stratified guidelines for recommended blood volume and monthly feedback to physicians were effective in optimizing blood volume for culture in a pediatric intensive care unit.


Assuntos
Hemocultura/métodos , Determinação do Volume Sanguíneo/métodos , Retroalimentação , Unidades de Terapia Intensiva Pediátrica , Bactérias/isolamento & purificação , Técnicas Bacteriológicas/métodos , Fungos/isolamento & purificação , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA