Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Codas ; 36(5): e20230241, 2024.
Artigo em Português, Inglês | MEDLINE | ID: mdl-39109754

RESUMO

PURPOSE: Propose normalization values of the Horus® computerized posturography platform, in children aged 4 to 6 years, without auditory and/or vestibular complaints. METHODS: Cross-sectional study, 216 children aged 4 to 6 years participated. All the children underwent to visual screening, audiological evaluation and computerized posturography, which consists of research on stability limits and seven sensory conditions. The results were statistically analyzed using the tests non-parametric Kruskal-Walli, post hoc Dunn-Bonferroni for pairwise age comparisons and the Mann-Whitney U for sex analysis. Categorical data were presented in relative frequency and quantitative data in mean and standard deviation. RESULTS: Standardization values were described for the stability limit and for the seven sensory conditions. There was a difference for the stability limit between sex at 4 years old(p<0.007) and, in the comparison between ages 4 and 5 (p=0.005) and 4 and 6 years old(p<0.001). In the residual functional balance, comparison between ages, there was a difference between 4 and 5, 4 and 6, 5 and 6 years, however for different data. The presence of statistical difference for different evaluation data also occurred in the analysis by sex. In the sensory systems, the findings between ages showed differences for the vestibular system, right and left optokinetic visual dependence, tunnel visual dependence and for the composite balance index. CONCLUSION: It was possible to establish normative values for the Horus® posturography in healthy children aged 4 to 6 years.


OBJETIVO: Propor valores de normatização da plataforma de posturografia computadorizada Horus®, em crianças de 4 a 6 anos, sem queixas auditivas e/ou vestibulares. MÉTODO: Estudo transversal. Participaram 216 crianças na faixa etária de 4 a 6 anos. Todas realizaram triagem visual, avaliação auditiva e posturografia computadorizada composta por pesquisa do limite de estabilidade e sete condições sensoriais. Analisaram-se os resultados estatisticamente por testes não paramétrico Kruskal-Walli, post hoc Dunn-Bonferroni para comparações par-a-par nas idades e U de Mann-Whitney para análise entre sexo. Os dados categóricos foram apresentados em frequência relativa e os dados quantitativos pela média e desvio padrão. RESULTADOS: Foram descritos valores de normatização para o limite de estabilidade e para as sete condições sensoriais. Houve diferença para o limite de estabilidade entre sexos aos 4 anos (p<0,007) e, na comparação entre as idades 4 e 5 anos (p=0,005) e 4 e 6 anos (p<0,001). No equilíbrio funcional residual, comparação entre idades, houve diferença entre 4 e 5, 4 e 6 e, 5 e 6 anos, entretanto para diferentes dados. A presença de diferença estatística para diferentes dados da avaliação, ocorreu também na análise por sexo. Nos sistemas sensoriais os achados entre idades mostraram diferença para o sistema vestibular, dependência visual optocinética direita e esquerda, dependência visual túnel e para índice de equilíbrio composto. Sugere-se que para esta população, as respostas na posturografia sejam analisadas por faixa etária e sexo. CONCLUSÃO: Foi possível estabelecer valores normativos para a posturografia Horus® em crianças hígidas na faixa etária de 4 a 6 anos.


Assuntos
Equilíbrio Postural , Humanos , Estudos Transversais , Pré-Escolar , Masculino , Feminino , Valores de Referência , Criança , Equilíbrio Postural/fisiologia , Testes de Função Vestibular/métodos , Testes de Função Vestibular/instrumentação , Testes de Função Vestibular/normas , Diagnóstico por Computador/normas , Diagnóstico por Computador/métodos
2.
Arq. bras. oftalmol ; 72(6): 783-788, Nov.-Dec. 2009. tab, graf
Artigo em Português | LILACS | ID: lil-536771

RESUMO

OBJETIVOS: Avaliar a medida de acuidade visual (AV), por meio da tabela de Snellen, em consultórios de três grandes centros oftalmológicos de Curitiba, comparar essas medidas entre si, com um método computadorizado para aferição de AV, e também, com o padrão teórico desenvolvido por Hermann Snellen. MÉTODOS: Estudo descritivo incluindo 15 consultórios oftalmológicos e um método computadorizado para a medida de AV. Com o auxílio de uma trena e um paquímetro foi realizada a medida da distância do olho do paciente sentado até a parede de projeção dos optotipos e, ao mesmo tempo, medido o tamanho da letra que era projetada na parede para 4 linhas de AV. RESULTADOS: Para a análise dos resultados, optamos por comparar os ângulos apresentados por cada consultório no momento da realização da medida. Sem surpresas, observou-se que nenhum consultório obteve o ângulo exato de 5 minutos de arco. Comparando-se os consultórios com o método computadorizado, observou-se que apenas 2 consultórios obtiveram melhores resultados se comparados os ângulos de projeção dos optotipos, porém os dados são muito próximos e insignificantes estatisticamente. Já em relação aos demais consultórios, a superioridade do método computadorizado é bastante relevante. Todos tiveram diferenças significantes em relação ao padrão-ouro. Ainda individualmente, comparou-se o método computadorizado com o padrão teórico Snellen e observou-se que esse obteve condições muito próximas do ideal, ou seja, em todas as acuidades visuais analisadas esteve sempre próximo dos 5 minutos de arco. CONCLUSÕES: Podemos concluir que existe uma grande heterogeneidade na avaliação da AV nos diferentes centros de oftalmologia. Também se pode esperar que para um mesmo paciente, avaliado em diferentes consultórios, há a possibilidade de se obter diferenças nas medidas da AV. O método computadorizado avaliado é prático, portátil, ajustável a distâncias diversas, mantém a razão de proporcionalidade...


PURPOSE: To evaluate the visual acuity (VA) measurement by Snellen chart at three main Ophthalmology centers in Curitiba, compare these measurements with a computerized method for calibrating VA and also with the standard theory developed by Hermann Snellen. METHODS: Descriptive study including 15 Ophthalmology clinics and a computerized method to measure the VA. Using a tape measure and a caliper, measurement of the distance was obtained from the sitting patients' eye to VA optotypes projection on the wall. At the same time, measurement of the size of the letters of 4 lines of the VA projection on the wall was performed. RESULTS: To analyze the results, it was opted to compare the angles presented by each clinic for each measurement. It was not surprising that no clinic presented an exact angle of 5 arch minutes. Comparing clinics results with computerized method, we observed that only 2 clinics obtained better results if compared with the angles obtained from optotypes projection, but the data is very similar and with no statistical significance. In relation to the other clinics, the superiority of the computerized method is very relevant. All had differences in comparison to the gold standard. Individually, comparing computerized method to standard Snellen theory, it was observed that a condition very close to the ideal was obtained, in other words, results very similar to 5 arch minutes were noted in all the visual acuities analyzed. CONCLUSIONS: It can be concluded that there is a great heterogeneity in the evaluation of VA in different Ophthalmology centers. Also, the same patient, evaluated in different clinics, can obtain different VA measurements. The computerized method is practical, portable, adjustable for different distances, and maintains optotypes proportionality ratio based on visual angle and approaches the theoretical values recommended by Herman Snellen in 1862.


Assuntos
Humanos , Diagnóstico por Computador/normas , Testes Visuais/métodos , Acuidade Visual/fisiologia , Diagnóstico por Computador/métodos , Reprodutibilidade dos Testes
3.
Arq. bras. oftalmol ; 69(6): 907-914, nov.-dez. 2006. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-440431

RESUMO

OBJETIVO: Elaborar e validar teste computadorizado para medida da acuidade visual de escolares. MÉTODOS: Foi elaborado teste computadorizado para determinação da acuidade visual utilizando os padrões das tabelas logarítmicas impressas adotadas na clínica oftalmológica. Foram avaliados 90 alunos da primeira série do ensino básico, oito estudantes do curso de Tecnologia Oftálmica da UNIFESP-EPM e 10 pacientes do ambulatório de Estrabismo do Departamento de Oftalmologia da UNIFESP-EPM. Todos os sujeitos foram avaliados pelo mesmo examinador e submetidos ao exame de acuidade visual monocular, pela tabela logarítmica de optotipos E impressa e do novo teste computadorizado no mesmo momento. Os participantes forneceram os seus consentimentos após esclarecimento. RESULTADOS: As análises estatísticas revelaram correlação excelente (r>0,75) entre os dois métodos, apesar da leve tendência apresentada pelo teste computadorizado em superestimar a acuidade visual quando comparado com o padrão-ouro. O teste computadorizado apresentou sensibilidade de 100 por cento e especificidade de 94 por cento. CONCLUSÕES: Os resultados obtidos nos permitem dizer que o teste computadorizado pode ser utilizado como novo recurso para triagem da qualidade visual dos escolares, por ser método rápido, de fácil aplicação, barato, automático e atrativo para as crianças. A automatização desvincula o aplicador da interpretação das respostas dadas pelo aluno testado, garante padronização do procedimento, que favorece as análises de acompanhamento e pode ser realizado por diferentes examinadores. Para melhor compreensão da efetividade do teste como instrumento de triagem visual, seria interessante instituí-lo nas escolas do curso básico, após treinamento dos professores para sua aplicação.


PURPOSE: To elaborate and to validate a computerized test for visual acuity screening of school-age children. METHODS: We have created a computerized test for visual acuity assessment with optotypes arranged as those of printed logarithmic charts used in ophthalmic clinic. Ninety seven-year-old students, 8 normal adult volunteers and 10 patients from the Strabismus sector of the Federal University of São Paulo were evaluated by the same examiner and submitted to the visual acuity test through printed visual acuity logarithmic tumble "E" chart and the new computerized test at the same time. Written consent was obtained after clarification about the research project. RESULTS: Statistical analysis showed excellent correlation between the two methods (r>0.75) besides the slight trend of the computerized test to overestimate visual acuity when compared with the gold standard. Sensitivity of the computerized test was 100 percent (correctly identified 6 eyes with poor visual acuity) and specificity was 94 percent. CONCLUSION: The computerized test can be used as a new clinical tool for visual acuity screening of school-age children and it is fast, easy to perform and inexpensive, besides being more attractive for children. The method releases the examiner from the interpretation of the subject's answers and ensures the procedure's standardization even when more than one examiner performs the test. To better understand the effectiveness of this method for visual screening, one option would be to introduce it in elementary schools, after training the teachers to perform this test.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Diagnóstico por Computador/normas , Transtornos da Visão/diagnóstico , Seleção Visual/normas , Testes Visuais/métodos , Acuidade Visual/fisiologia , Interpretação Estatística de Dados , Diagnóstico por Computador/economia , Diagnóstico por Computador/métodos , Matemática , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estrabismo , Percepção de Tamanho/fisiologia , Transtornos da Visão/prevenção & controle , Seleção Visual/economia , Seleção Visual/métodos
4.
Rev. bras. eng. biomed ; 17(3): 151-163, set.-dez. 2001. ilus, graf
Artigo em Português | LILACS | ID: lil-417482

RESUMO

Este trabalho apresenta a implementação de um protocolo para a aquisição dos parâmetros do feixe acústico de transdutores ultra-sônicos usados em medicina, baseado em normas nacionais e internacionais. O software ATUS (Avaliação de Transdutores Ultrs-Sônicos) foi desenvolvido em MATLAB (Mathworks, Natick, MA) e se apresenta como uma ferramenta amigável para visualização dos perfis do feixe (paralelo e perpendicular à face do transdutor) e para a obtenção e cálculo dos parâmetros de interesse, como intensidade acústica e características geométricas do feixe (distância focal, comprimento focal e área focal). O protocolo é aplicável ao feixe de transdutores usados tanto em diagnóstico como em fisioterapia. A interpolação de mapeamentos 2D sub-amostrados é apresentada como uma metodologia alternativa ao mapeamento 1D em diversas direções paralelas à face do transdutor, proposto pela Norma ABNT - IEC 1689 (1998)


Assuntos
Transdutores , Diagnóstico por Computador/instrumentação , Diagnóstico por Computador/normas , Processamento de Imagem Assistida por Computador , Ultrassonografia , Equipamentos para Diagnóstico , Segurança de Equipamentos/instrumentação , Segurança de Equipamentos/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA