1.
Biomed Phys Eng Express ; 10(5)2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39094590

RESUMO

Purpose. Secondary skin collimation (SSC) is essential for shielding normal tissues near tumors during electron and orthovoltage radiation treatments. Traditional SSC fabrication methods, such as crafting in-house lead sheets, are labor-intensive and produce SSCs with low geometric accuracy. This study introduces a workflow that integrated 3D scanning and 3D printing technologies with an in-house mold process, enabling the production of patient-specific SSCs within six hours.Methods. An anthropomorphic head phantom was scanned with a handheld 3D scanner. The resulting scan data was imported into 3D modeling software for design. The completed model was exported to a 3D printer as a printable file. Subsequently, molten Cerrobend was poured into the mold and allowed to set, completing the SSC production. Geometric accuracy was assessed using CT images, and the shielding effectiveness was evaluated through film dosimetry.Results. The 3D printed mold achieved submillimeter accuracy (0.5 mm) and exhibited high conformity to the phantom surface. It successfully endured the weight and heat of the Cerrobend during pouring and curing. Dosimetric analysis conducted with radiochromic film demonstrated good agreement between the measured and expected attenuation values of the SSC slab, within ±3%.Conclusions. This study presents a proof of concept for novel mold room workflows that produce patient-specific SSCs within six hours, a significant improvement over the traditional SSC fabrication process, which takes 2-3 days. The submillimeter accuracy and versatility of 3D scanning and printing technologies afford greater design freedom and enhanced delivery accuracy for cases involving irregular geometries.


Assuntos
Imagens de Fantasmas , Impressão Tridimensional , Pele , Humanos , Tomografia Computadorizada por Raios X/métodos , Software , Cabeça , Desenho de Equipamento , Proteção Radiológica/métodos , Proteção Radiológica/instrumentação , Dosimetria Fotográfica/métodos , Dosimetria Fotográfica/instrumentação
2.
Phys Med ; 124: 103420, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38970950

RESUMO

PURPOSE: The purpose of this study is to investigate the dosimetric characteristics of a collimator for minibeam radiotherapy (MBRT) with film dosimetry and Monte Carlo (MC) simulations. The outcome of MBRT with respect to conventional RT using a glioma preclinical model was also evaluated. METHODS: A multi-slit collimator was designed to be used with commercial small animal irradiator. The collimator was built by aligning 0.6 mm wide and 5 mm thick parallel lead leaves at 0.4 mm intervals. Dosimetry characteristics were evaluated by Gafchromic (CG) films and TOPAS Monte Carlo (MC) code. An in vivo experiment was performed using a glioma preclinical model by injecting two million GL261cells subcutaneously and treating with 25 Gy, single fraction, with MBRT and conventional RT. Survival curves and acute radiation damage were measured to compare both treatments. RESULTS: A satisfactory agreement between experimental results and MC simulations were obtained, the measured FWHM and distance between the peaks were respectively 0.431 and 1.098 mm. In vivo results show that MBRT can provide local tumor control for three weeks after RT treatment and a similar survival fraction of open beam radiotherapy. No severe acute effects were seen for the MBRT group. CONCLUSIONS: We developed a minibeam collimator and presented its dosimetric features. Satisfactory agreement between MC and GC films was found with differences consistent with uncertainties due to fabrication and set-up errors. The survival curves of MBRT and open field RT are similar while atoxicity is dramatically lower with MBRT, preliminarily confirming the expected effect.


Assuntos
Glioma , Método de Monte Carlo , Fótons , Glioma/radioterapia , Animais , Fótons/uso terapêutico , Camundongos , Radiometria , Linhagem Celular Tumoral , Dosagem Radioterapêutica , Dosimetria Fotográfica , Radioterapia/métodos , Radioterapia/instrumentação , Neoplasias Encefálicas/radioterapia
3.
Biomed Phys Eng Express ; 10(5)2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38941982

RESUMO

Gafchromic film, a commercially available radiochromic film, has been developed and widely used as an effective tool for radiation dose verification and quality assurance in radiotherapy. However, the orientation effect in scanning a film remains a concern for practical application in beam profile monitoring. To resolve this issue, the authors introduced a novel method using an overhead scanner (OHS) coupled with a tracing light board instead of a conventional flatbed scanner (FBS) to read Gafchromic EBT3 films. We investigated the orientation effect of the EBT3 film with a regular hexagonal shape after irradiation with 5 Gy x-rays (160 kV, 6.3 mA) and compared the digitized images acquired using a commercially available OHS (CZUR Aura) and a conventional FBS (EPSON GT-X980). As a result, RGB color intensities acquired from the OHS showed significantly lower orientation effect of the color intensities of RGB components than those from FBS. This finding indicates the high potential of the proposed method for achieving more precise two-dimensional dosimetry. Further studies are required to confirm the effectiveness of this method under different irradiation conditions over a wider dose range.


Assuntos
Dosimetria Fotográfica , Dosimetria Fotográfica/métodos , Dosimetria Fotográfica/instrumentação , Desenho de Equipamento , Humanos , Doses de Radiação , Cor , Dosagem Radioterapêutica
4.
J Appl Clin Med Phys ; 25(8): e14373, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38696704

RESUMO

PURPOSE: Lateral response artifact (LRA) is caused by the interaction between film and flatbed scanner in the direction perpendicular to the scanning direction. This can significantly affect the accuracy of patient-specific quality assurance (QA) in cases involving large irradiation fields. We hypothesized that by utilizing the central area of the flatbed scanner, where the magnitude of LRA is relatively small, the LRA could be mitigated effectively. This study proposes a practical solution using the image-stitching technique to correct LRA for patient-specific QA involving large irradiation fields. METHODS: Gafchromic™ EBT4 film and Epson Expression ES-G11000 flatbed scanner were used in this study. The image-stitching algorithm requires a spot between adjacent images to combine them. The film was scanned at three locations on a flatbed scanner, and these images were combined using the image-stitching technique. The combined film dose was then calculated and compared with the treatment planning system (TPS)-calculated dose using gamma analysis (3%/2 mm). Our proposed LRA correction was applied to several films exposed to 18 × 18 cm2 open fields at doses of 200, 400, and 600 cGy, as well as to four clinical Volumetric Modulated Arc Therapy (VMAT) treatment plans involving large fields. RESULTS: For doses of 200, 400, and 600 cGy, the gamma analysis values with and without LRA corrections were 95.7% versus 67.8%, 95.5% versus 66.2%, and 91.8% versus 35.9%, respectively. For the clinical VMAT treatment plan, the average pass rate ± standard deviation in gamma analysis was 94.1% ± 0.4% with LRA corrections and 72.5% ± 1.5% without LRA corrections. CONCLUSIONS: The effectiveness of our proposed LRA correction using the image-stitching technique was demonstrated to significantly improve the accuracy of patient-specific QA for VMAT treatment plans involving large irradiation fields.


Assuntos
Algoritmos , Artefatos , Dosimetria Fotográfica , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Dosimetria Fotográfica/métodos , Dosimetria Fotográfica/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Garantia da Qualidade dos Cuidados de Saúde/normas , Radioterapia de Intensidade Modulada/métodos
5.
J Appl Clin Med Phys ; 25(8): e14416, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38812120

RESUMO

BACKGROUND AND PURPOSE: This study recommends clinical epidermal dose calculation methods based on in-vivo film measurements and registered skin dose distributions with the Eclipse (Varian Medical Systems) treatment planning system's Analytical Anisotropic Algorithm (AAA) and Acuros XB (AXB) dose calculation algorithms. MATERIALS AND METHODS: Eighteen AAA V13.6 breast plans were recalculated using AXB (dose to medium) V13.5 with the same beam parameters and monitor units as in the original plans. These are compared against in-vivo Gafchromic film measurements from the lateral and inferior breast regions. Three skin structures in the treatment planning system are evaluated: a surface layer of voxels of the body contour, a 0.2 cm internal skin rind, and a 0.5 cm internal skin rind. RESULTS: Systematic shifts are demonstrated between the film measurements of skin dose and the Eclipse dose calculations. On average, the dose to the surface layer of pixels is underestimated by AAA by 8% and overestimated by AXB by 3%. A 5 mm skin rind extended into the body can increase epidermal dose calculations on average by 8% for AAA and 4% for AXB. CONCLUSION: This is the first study to register in-vivo skin dose distributions in the breast to the treatment planning system for comparison. Based on the results from this study it is recommended that epidermal dose is calculated with a 0.5 cm skin rind for the AAA algorithm and with rind thickness up to 0.2 cm for the AXB algorithm.


Assuntos
Algoritmos , Neoplasias da Mama , Dosimetria Fotográfica , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Feminino , Neoplasias da Mama/radioterapia , Anisotropia , Dosimetria Fotográfica/métodos , Radioterapia de Intensidade Modulada/métodos , Epiderme/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Imagens de Fantasmas
6.
Phys Med Biol ; 69(10)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38565123

RESUMO

Objective.To evaluate the reduction in energy dependence and aging effect of the lithium salt of pentacosa-10,-12-diynoic acid (LiPCDA) films with additives including aluminum oxide (Al2O3), propyl gallate (PG), and disodium ethylenediaminetetracetate (EDTA).Approach. LiPCDA films exhibited energy dependence on kilovoltage (kV) and megavoltage (MV) photon energies and experienced deterioration over time. Evaluations were conducted with added Al2O3and antioxidants to mitigate these issues, and films were produced with and without Al2O3to assess energy dependence. The films were irradiated at doses of 0, 3, 6, and 12 cGy at photon energies of 75 kV, 105 kV, 6 MV, 10 MV, and 15 MV. For the energy range of 75 kV to 15 MV, the mean and standard deviation (std) were calculated and compared for the values normalized to the net optical density (netOD) at 6 MV, corresponding to identical dose levels. To evaluate the aging effect, PG and disodium EDTA were incorporated into the films: sample C with 1% PG, sample D with 2% PG, sample E with 0.62% disodium EDTA added to sample D, and sample F with 1.23% disodium EDTA added to sample D.Main results. Films containing Al2O3demonstrated a maximum 15.8% increase in mean normalized values and a 15.1% reduction in std, reflecting a greater netOD reduction at kV than MV energies, which indicates less energy dependence in these films. When the OD of sample 1-4 depending on the addition of PG and disodium EDTA, was observed for 20 weeks, the transmission mode decreased by 8.7%, 8.3%, 29.3%, and 27.3%, respectively, while the reflection mode was 5.4%, 3.0%, 37.0%, and 34.5%, respectively.Significance. Al2O3effectively reduced the voltage and MV energy dependence. PG was more effective than disodium EDTA in preventing the deterioration of film performance owing to the aging effect.


Assuntos
Dosimetria Fotográfica , Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/métodos , Óxido de Alumínio/química , Ácido Edético/química , Galato de Propila , Fótons
7.
Radiat Environ Biophys ; 63(2): 203-214, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38683360

RESUMO

The study aimed to evaluate dosimetry systems used for stereotactic body radiotherapy (SBRT), specifically 2D array dosimetry and film dosimetry systems, for exploring their characteristics and clinical suitability. For this, high-resolution myQA SRS detectors and Gafchromic EBT-XD films were employed. Film analysis included net optical density (OD) values depending on energy, dose rate, scanner orientation, scanning side, and post-exposure growth. For myQA SRS, signal values were evaluated in terms of dose rate (400-1400 MU/min) and angular dependence (0-180° at 30° intervals) along with couch angles of 0°, 45°, and 90°. Pre-treatment verification included 32 SBRT patients for whom myQA SRS results were compared with those obtained with Gafchromic EBT-XD films. Analysis revealed less than 1% deviation in net OD for energy and dose rate dependence. Scanner orientation caused 2.5% net OD variation, with minimal differences between film front and back scan orientations (variance < 1.0%). A rapid OD rise occurred within six hours post-exposure, followed by gradual increase. The myQA SRS detector showed - 3.7% dose rate dependence (400 MU/min), while the angular dependence at 90° was - 26.7%. A correction factor effectively reduced these differences to < 1%. For myQA SRS, gamma passing rates were-93.6% (2%/1 mm), while those for EBT-XD films were-92.8%. Improved rates were observed with 3%/1 mm: for myQA SRS-97.9%, and for EBT-XD film-98.16%. In contrast, for 2%/2 mm with 10% threshold, for myQA SRS-97.7% and for EBT-XD film-98.97% were obtained. It is concluded that both myQA SRS detectors and EBT-XD films are suitable for SBRT pre-treatment verification, ensuring accuracy and reliability. However, myQA SRS detectors are preferred over EBT-XD film due to the fact that they offer real-time measurements and user-friendly features.


Assuntos
Dosimetria Fotográfica , Radiocirurgia , Radiocirurgia/métodos , Humanos , Dosagem Radioterapêutica
8.
J Appl Clin Med Phys ; 25(7): e14325, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38467039

RESUMO

PURPOSE: The picket fence (PF) test is highly recommended for multi-leaf collimator (MLC) quality assurance. However, since the electronic portal imaging device (EPID) on the Elekta Unity only covers a small area, it is not feasible to perform the PF test for the entire MLC. Here, we propose a technique for the PF test by stitching two double-exposed films. METHODS: Two EBT3 films were used to encompass the entire MLC, with each one covering one half of the area. Two fields were employed to apply double exposure: a PF pattern consisting of 11 2 mm wide pickets and a 2.84 cm x 22 cm open field. The edges of the open field defined by the diaphragms were used to correct film rotation as well as align them horizontally. The PF pattern was also measured with the EPID where the pickets were used to align the films vertically. Individual leaf positions were detected on the merged film for quantitative analysis. Various MLC positioning errors were introduced to evaluate the technique's sensitivity. RESULTS: The merged films covered 72 leaf pairs properly (four leaf pairs on both sides were outside the treatment couch). With the EPID, the leaf positioning accuracy was -0.02 ± 0.07 mm (maximum: 0.29 mm) and the picket width variation was 0.00 ± 0.03 mm (maximum: 0.11 mm); with the films, the position accuracy and width variation were -0.03 ± 0.13 mm (maximum: 0.80 mm) and 0.00 ± 0.13 mm (maximum: 0.74 mm), respectively. The EPID was able to detect errors of 0.5 mm or above with submillimeter accuracy; the films were only able to detect errors > 1.0 mm. CONCLUSION: We developed a quantitative technique for the PF test on the Elekta Unity. The merged films covered nearly the entire MLC leaf banks. The technique exhibited clinically acceptable accuracy and sensitivity to MLC positioning errors.


Assuntos
Aceleradores de Partículas , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Garantia da Qualidade dos Cuidados de Saúde/normas , Radioterapia de Intensidade Modulada/métodos , Aceleradores de Partículas/instrumentação , Imageamento por Ressonância Magnética/métodos , Dosimetria Fotográfica/métodos , Dosimetria Fotográfica/instrumentação , Imagens de Fantasmas , Neoplasias/radioterapia
9.
Phys Med Biol ; 69(7)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38394683

RESUMO

Optically stimulated luminescence (OSL) film dosimeters, based on BaFBr:Eu2+phosphor material, have major dosimetric advantages such as dose linearity, high spatial resolution, film re-usability, and immediate film readout. However, they exhibit an energy-dependent over-response at low photon energies because they are not made of tissue-equivalent materials. In this work, the OSL energy-dependent response was optimized by lowering the phosphor grain size and seeking an optimal choice of phosphor concentration and film thickness to achieve sufficient signal sensitivity. This optimization process combines measurement-based assessments of energy response in narrow x-ray beams with various energy response calculation methods applied to different film metrics. Theoretical approaches and MC dose simulations were used for homogeneous phosphor distributions and for isolated phosphor grains of different dimensions, where the dose in the phosphor grain was calculated. In total 8 OSL films were manufactured with different BaFBr:Eu2+median particle diameters (D50): 3.2µm, 1.5µm and 230 nm and different phosphor concentrations (1.6%, 5.3% and 21.3 %) and thicknesses (from 5.2 to 49µm). Films were irradiated in narrow x-ray spectra (N60, N80, N-150 and N-300) and the signal intensity relative to the nominal dose-to-water value was normalized to Co-60. Finally, we experimentally tested the response of several films in Varian 6MV TrueBeam STx linear accelerator using the following settings: 10 × 10 cm2field, 0deggantry angle, 90 cm SSD, 10 cm depth. The x-ray irradiation experiment reported a reduced energy response for the smallest grain size with an inverse correlation between response and grain size. The N-60 irradiation showed a 43% reduction in the energy over-response when going from 3µm to 230 nm grain size for the 5% phosphor concentration. Energy response calculation using a homogeneous dispersion of the phosphor underestimated the experimental response and was not able to obtain the experimental correlation between grain size and energy response. Isolated grain size modeling combined with MC dose simulations allowed to establish a good agreement with experimental data, and enabled steering the production of optimized OSL-films. The clinical 6 MV beam test confirmed a reduction in energy dependence, which is visible in small-grain films where a decrease in out-of-field over-response was observed.


Assuntos
Dosimetria por Luminescência Estimulada Opticamente , Método de Monte Carlo , Radiometria , Luminescência , Raios X , Dosimetria Fotográfica/métodos
10.
Br J Radiol ; 97(1155): 646-651, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38273671

RESUMO

OBJECTIVES: To establish the variation in film dosimetry usage in radiotherapy centres across the United Kingdom. To identify consensus and highlight areas of potential improvement to enhance radiotherapy dosimetry verification with film. METHODS: A survey questionnaire was designed by members of the Institute of Physics and Engineering in Medicine Interdepartmental Dosimetry Audit Group via Microsoft Forms and distributed to all Heads of Radiotherapy Physics in the United Kingdom. The survey was open from June 19, 2023, to July 31, 2023. RESULTS: Forty responses were received from the 62 radiotherapy centres in the United Kingdom, of which 58% were currently using film dosimetry and a further 7 were keen to commence use. Many reported film use had decreased in recent years but was still valuable particularly for commissioning and implementing new techniques. The variation and consensus of methods for film dosimetry calibration, measurement, and application was established. A review of barriers to implementation and methods to reduce uncertainty were included in the assessment. CONCLUSIONS: A comprehensive assessment of film dosimetry usage in radiotherapy in the United Kingdom has been collated, which demonstrates a wide variation in methods, across typical clinical users, but maintains film as a valuable dosimetry option. ADVANCES IN KNOWLEDGE: This research provides a snapshot of current film dosimetry use across the United Kingdom. It examines the variation and consensus of practice to which individual users can compare their systems, and identifies opportunities to improvement in the accuracy of film dosimetry.


Assuntos
Dosimetria Fotográfica , Radioterapia (Especialidade) , Humanos , Dosagem Radioterapêutica , Dosimetria Fotográfica/métodos , Radiometria , Reino Unido , Calibragem
11.
Med Phys ; 51(5): 3734-3745, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38224326

RESUMO

BACKGROUND: Cherenkov luminescence imaging has shown potential for relative dose distribution and field verification in radiation therapy. However, to date, limited research utilizing Cherenkov luminescence for absolute dose calibration has been conducted owing to uncertainties arising from camera positioning and tissue surface optical properties. PURPOSE: This paper introduces a novel approach to multispectral Cherenkov luminescence imaging combined with Fricke-xylenol orange gel (FXG) film, termed MCIFF, which can enable online full-field absolute dose measurement. By integrating these two approaches, MCIFF allows for calibration of the ratio between two spectral intensities with absorbed dose, thereby enabling absolute dose measurement. METHODS: All experiments are conducted on a Varian Clinac 23EX, utilizing an electron multiplying charge-coupled device (EMCCD) camera and a two-way image splitter for simultaneous capture of two-spectral Cherenkov imaging. In the first part of this study, the absorbance curves of the prepared FXG film, which receives different doses, are measured using a fluorescence spectrophotometer to verify the correlation between absorbance and dose. In the second part, the FXG film is positioned directly under the radiation beam to corroborate the dose measurement capacity of MCIFF across various beams. In the third part, the feasibility of MCIFF is tested in actual radiotherapy settings via a humanoid model, demonstrating its versatility with various radiotherapy materials. RESULTS: The results of this study indicate that the logarithmic ratios of spectral intensities at wavelengths of 550 ± 50 and 700 ± 100 nm accurately reflect variations in radiation dose (R2 > 0.96) across different radiation beams, particle energies, and dose rates. The slopes of the fitting lines remain consistent under varying beam conditions, with discrepancies of less than 8%. The optical profiles obtained using the MCIFF exhibit a satisfactory level of agreement with the measured results derived from the treatment planning system (TPS) and EBT3 films. Specifically, for photon beams, the lateral distances between the 80% and 20% isodose lines, referred to as the penumbra (P80-20) values, obtained through TPS, EBT3 films, and MCIFF, are determined as 0.537, 0.664, and 0.848 cm, respectively. Similarly, for electron beams, the P80-20 values obtained through TPS, EBT3 films, and MCIFF are found to be 0.432, 0.561, and 0.634 cm, respectively. Furthermore, imaging of the anthropomorphic phantom demonstrates the practical application of MCIFF in real radiotherapy environments. CONCLUSION: By combining an FXG film with Cherenkov luminescence imaging, MCIFF can calibrate Cherenkov luminescence to absorbed dose, filling the gap in online 2D absolute dose measurement methods in clinical practice, and providing a new direction for the clinical application of optical imaging to radiation therapy.


Assuntos
Dosimetria Fotográfica , Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/métodos , Calibragem , Géis , Xilenos/química , Doses de Radiação , Sulfóxidos , Fenóis , Imagem Óptica/instrumentação
12.
Phys Med Biol ; 69(5)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38295408

RESUMO

Objective.Spatially-fractionated radiotherapy (SFRT) delivered with a very-high-energy electron (VHEE) beam and a mini-GRID collimator was investigated to achieve synergistic normal tissue-sparing through spatial fractionation and the FLASH effect.Approach.A tungsten mini-GRID collimator for delivering VHEE SFRT was optimized using Monte Carlo (MC) simulations. Peak-to-valley dose ratios (PVDRs), depths of convergence (DoCs, PVDR ≤ 1.1), and peak and valley doses in a water phantom from a simulated 150 MeV VHEE source were evaluated. Collimator thickness, hole width, and septal width were varied to determine an optimal value for each parameter that maximized PVDR and DoC. The optimized collimator (20 mm thick rectangular prism with a 15 mm × 15 mm face with a 7 × 7 array of 0.5 mm holes separated by 1.1 mm septa) was 3D-printed and used for VHEE irradiations with the CERN linear electron accelerator for research beam. Open beam and mini-GRID irradiations were performed at 140, 175, and 200 MeV and dose was recorded with radiochromic films in a water tank. PVDR, central-axis (CAX) and valley dose rates and DoCs were evaluated.Main results.Films demonstrated peak and valley dose rates on the order of 100 s of MGy/s, which could promote FLASH-sparing effects. Across the three energies, PVDRs of 2-4 at 13 mm depth and DoCs between 39 and 47 mm were achieved. Open beam and mini-GRID MC simulations were run to replicate the film results at 200 MeV. For the mini-GRID irradiations, the film CAX dose was on average 15% higher, the film valley dose was 28% higher, and the film PVDR was 15% lower than calculated by MC.Significance.Ultimately, the PVDRs and DoCs were determined to be too low for a significant potential for SFRT tissue-sparing effects to be present, particularly at depth. Further beam delivery optimization and investigations of new means of spatial fractionation are warranted.


Assuntos
Elétrons , Dosimetria Fotográfica , Método de Monte Carlo , Dosimetria Fotográfica/métodos , Síncrotrons , Carmustina , Água , Dosagem Radioterapêutica , Radiometria
14.
Rev. cuba. hig. epidemiol ; 35(2): 85-93, jul.-dic. 1997. tab, graf
Artigo em Espanhol | LILACS | ID: lil-228135

RESUMO

Se presentan los resultados de la distribución de dosis de los trabajadores vigilados (TV) en röentgendiagnóstico médico en Cuba durante el período comprendido entre 1991 y 1994. El análisis se realizó según las recomendaciones del Comité Científico de las Naciones Unidas para el estudio de los Efectos de la Radiaciones Atómicas (UNSCEAR). Se observó una brusca disminución en el número de trabajadores expuestos a niveles mediables (TENM) a partir de 1991, se establece una gran desproporción de éstos con respecto al número de TV y se discuten sus causas. Los TENM con dosis mayores que los 3/10 del límite permisible de dosis vigente, poseen el peso de la contribución la dosis colectiva recibida por los TV en el período, con cerca del 22 porciento. Se realiza un análisis de la repercusión en los resultados del nuevo límite permisible de dosis para la exposición ocupacional. Se recomienda un mejoramiento del sistema dosimétrico y en general del sistema de protección radiológica que incrementen la calidad en el control de la exposición ocupacional en röentgendiagnóstico médico


Assuntos
Humanos , Dosimetria Fotográfica/métodos , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Pessoal de Saúde , Proteção Radiológica/métodos , Efeitos da Radiação , Gestão de Riscos , Cuba
15.
Periodontia ; 5(4): 359-63, jul.-dez. 1996. ilus, tab
Artigo em Português | BBO - odontologia (Brasil) | ID: biblio-853588

RESUMO

O presente estudo tem por objetivo avaliar a influência do tempo de exposição da película aos raios X e do tipo de sensibilidade do filme no controle de qualidade na interpretação radiográfico periodontal. Diferentes tipos de defeitos ósseos foram criados em dois crânios secos: horizontal, vertical, cratera, circunferencial, de três paredes (mesial e distal), vestibular, lingual e com extensão apical. Onze tomadas radiográficas foram realizadas em cada região que apresentava defeito ósseo variando o tempo de exposição de: 0,2; 0,4; 0,6; 0,8; 1,0; 1,2; 1,4; 1,6; 1,8; 2,0; 2,2 segundos. Foram utilizados para comparação filmes radiográficos da marca Kodak de diferentes sensibilidades: Ultra-speed e Ektaspeed. Após processamento radiográfico padronizado, as radiografias foram analisadas por examinadores calibrados. Os resultados demonstraram existir diferenças significativas na interpretação radiográfica periodontal quando da variação dos fatores de tempo de exposição e sensibilidade do filme radiográfico


Assuntos
Humanos , Masculino , Feminino , Crânio , Dosimetria Fotográfica , Perda do Osso Alveolar , Controle de Qualidade , Radiografia Dentária , Filme para Raios X , Raios X
16.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.487-488, graf.
Monografia em Português | LILACS | ID: lil-233832

RESUMO

Este trabalho analisa os resultados da monitoração individual externa de trabalhadores da área médica enfocando os níveis de dose em diferentes departamentos de diferentes hospitais.


Assuntos
Pele/efeitos da radiação , Cristalino/efeitos da radiação , Doses de Radiação , Monitoramento de Radiação/estatística & dados numéricos , Qualidade da Assistência à Saúde/normas , Brasil , Hospitais , Rede Nervosa , Dosimetria Fotográfica , Redes Neurais de Computação
17.
Rev. cuba. hig. epidemiol ; 33(1/2): 3, ene.-dic. 1995. ilus
Artigo em Espanhol | LILACS | ID: lil-168834

RESUMO

Se describe el metodo seguido en el Departamento de Higiene de las Radiaciones del Instituto de Medicina del Trabajo para la vigilancia radiologica individual del personal ocupacionalmente expuesto en radiodiagnostico medico en Cuba. Como control dosimetrico se emplea la dosimetria filmica personal. Se detalla la implementacion en computadora de los algoritmos de calculo y el registro de las dosis equivalentes. El calculo se realiza a partir de un analisis de las dosis aparentes detras de los diferentes filtros para tener en cuenta la compensacion por dependencia energatica, actualizandose las dosis acumulada anual. Tambien se puede calcular el rango energetico al que ha sido irradiado un dosimetro. El codigo desarrollado automatiza los calculos y posibilita un metodo de relativa mayor complejidad y precision, y permite disponer de archivos de alta confiabilidad y rapido acceso con los resultados y los datos de interes del personal controlado. El sistema ha demostrado su eficacia en el monitoreo del personal controlado (AUR


Assuntos
Humanos , Masculino , Feminino , Dosimetria Fotográfica/métodos , Nível de Saúde , Lesões por Radiação/prevenção & controle , Doenças Profissionais/prevenção & controle , Radiografia/efeitos adversos
18.
ROBRAC ; 4(11): 10-6, jun. 1994. ilus
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: lil-138523

RESUMO

Dada a grande importância do exame radiográfico como complemento no diagnóstico, e sabendo dos efeitos biológicos dos raios X, muitos estudos têm sido realizados para a determinaçäo das doses de radiaçäo que atingem o organismo humano. Neste trabalho nos preocupamos com algumas técnicas extra-bucais como as de Waters, Granger e Shuller e as doses que atingem as gônadas, glândula tireóide e o cristalino na aplicaçäo de cada uma dessas técnicas. Estabeleceu-se comparaçöes sobre os métodos utilizados (filmes dosimétricos e dosímetros termoluminescentes de fluoreto de lítio - Lif 700), os tipos morfológicos estudados com a finalidade de encontrar meios para diminuir os índices de radiaçäo (fatores elétricos, filtraçäo e filmes) nos órgäos críticos citados


Assuntos
Humanos , Efeitos da Radiação , Radiografia Dentária/efeitos adversos , Raios X/efeitos adversos , Dosimetria Fotográfica , Face/anatomia & histologia , Glândula Tireoide/efeitos da radiação , Cristalino/efeitos da radiação
19.
In. Freitas, Leonidas de. Radiologia bucal: técnicas e interpretaçäo. Säo Paulo, Pancast, 1992. p.52-63, ilus, graf.
Monografia em Português | LILACS, BBO - odontologia (Brasil) | ID: lil-250616
20.
In. Freitas, Leonidas de. Radiologia bucal: técnicas e interpretaçäo. Säo Paulo, Pancast, 1992. p.65-78, ilus.
Monografia em Português | LILACS, BBO - odontologia (Brasil) | ID: lil-250617