Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 299
Filtrar
1.
Cardiovasc Toxicol ; 24(1): 41-48, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38108958

RESUMO

Cardiac magnetic resonance imaging is the gold standard to detect cardiac iron overload in patients with beta-thalassemia. The aim of this study was to evaluate cardiac iron overload using four-dimensional transthoracic echocardiography in thalassemia patients with and without cardiac involvement detected by T2* value and to compare the two techniques. This cross-sectional and observational study was conducted in 44 patients diagnosed with thalassemia major. Left ventricular systolic function was assessed using four-dimensional speckle tracking echocardiography-derived global longitudinal (GLS), circumferential, radial, and area strain indices. Left ventricular ejection fraction, volumes, and mass index were similar between the patients with T2* values less than 20 ms as compared to those with T2* values greater than 20 ms. However, patients with lower T2* values had significantly higher GLS values (- 17.0% vs. - 19.8%, p < 0.001) compared with those with higher T2* values. GLS demonstrated a sensitivity of 91.7% and a specificity of 71.9% at a cut-off value of - 18.5%; however, sensitivity was 75%, and the specificity was 84.4% at a cut-off value of - 17.5%. For - 18.5%, the positive predictive value was 55%, and the negative predictive value was 95.8%; for - 17.5%, these values were 64.2 and 90%, respectively. This novel echocardiographic method, tested for the first time in our study in comparison with cardiac MRI in an adult patient group, has been shown to predict cardiac iron overload in thalassemia patients in the subclinical period without LVEF decline. Four-dimensional GLS is a marker with high sensitivity and negative predictive value.


Assuntos
Sobrecarga de Ferro , Talassemia , Disfunção Ventricular Esquerda , Talassemia beta , Adulto , Humanos , Talassemia beta/complicações , Talassemia beta/diagnóstico por imagem , Volume Sistólico , Estudos Transversais , Função Ventricular Esquerda , Sobrecarga de Ferro/diagnóstico por imagem , Sobrecarga de Ferro/etiologia , Imageamento por Ressonância Magnética/métodos , Ecocardiografia Quadridimensional , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia
2.
Echocardiography ; 40(12): 1365-1373, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37965911

RESUMO

BACKGROUND: Polycythemia vera (PV), characterized by elevated red blood cell counts, poses challenges to cardiovascular health with potential impacts on cardiac function. Myocardial infarction (MI) and heart failure are major causes of mortality in PV patients. Early detection of left ventricular systolic dysfunction is crucial for optimizing outcomes. METHODS: Fifty-two PV patients and 45 healthy controls were recruited. Four-dimensional speckle tracking echocardiography (4D-STE) and fragmented QRS complexes (fQRS) on electrocardiograms were utilized to assess cardiac mechanics. Hematological and echocardiographic parameters were measured, and statistical analyses were performed. RESULTS: PV patients exhibited significantly higher hematocrit and red cell distribution width compared to controls. Global longitudinal strain (GLS), global circumferential strain (GCS), global radial strain (GRS), and global area strain (GAS) were lower in PV patients. fQRS complexes were associated with longer disease duration and reduced GCS and GAS values. Hematocrit correlated positively with LV-GCS and LV-GAS. Multiple linear regression revealed that disease duration and fQRS presence independently predicted LV-GAS. CONCLUSION: This study underscores the intricate link between elevated red blood cell counts, disease duration, and cardiac function in PV patients. Combining 4D-STE and fQRS complexes enhances the identification of early left ventricular systolic dysfunction. These findings offer potential improvements in recognizing and managing cardiovascular complications in PV patients, with implications for future research and clinical practice. Further investigations are needed to elucidate underlying mechanisms and validate these markers in larger cohorts.


Assuntos
Ecocardiografia Tridimensional , Policitemia Vera , Disfunção Ventricular Esquerda , Humanos , Policitemia Vera/complicações , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico por imagem , Coração , Eletrocardiografia , Ecocardiografia Quadridimensional , Função Ventricular Esquerda/fisiologia , Ecocardiografia Tridimensional/métodos
3.
Echocardiography ; 40(2): 113-127, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36647764

RESUMO

BACKGROUND: Tricuspid annulus (TA) geometry and function reference values are limited, especially for Asian populations. We aimed to explore TA using four-dimensional echocardiography (4DE) in a healthy Asian population. METHODS: A total of 355 healthy Asian volunteers (median age 34 years; 52% males) were prospectively enrolled. TA geometry and function were analyzed using 4DE throughout the cardiac cycle. RESULTS: The TA area, perimeter, and dimensions were smallest at end systole (ES) and largest at late diastole (LD). Normal TA parameters at end diastole (ED) in different sex and age groups were obtained. TA areas, perimeters, and dimensions in males were significantly larger than those in females at ED; BSA-indexed perimeters and BSA-indexed dimensions in males were significantly smaller than those in females at ED. TA parameters correlated well with tricuspid valve (TV) tenting, right ventricle (RV), and right atrium (RA) parameters. CONCLUSIONS: Reference values of TA parameters were obtained by 4DE in an Asian population. Quantitative data on TA geometry and function are essential for TA pathology and therapeutics.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Tricúspide , Masculino , Feminino , Humanos , Adulto , Ecocardiografia Quadridimensional , Ecocardiografia Tridimensional/métodos , Valva Tricúspide , Átrios do Coração/diagnóstico por imagem
4.
Int J Gynaecol Obstet ; 160(1): 136-144, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35695073

RESUMO

OBJECTIVE: This study investigated the feasibility and accuracy of fetal intelligent navigation echocardiography (FINE) for the prenatal diagnosis of congenital heart disease (CHD) by inexperienced and experienced operators. METHOD: In this prospective study, all volume data sets from 120 fetuses with a broad spectrum of CHD were acquired using spatiotemporal image correlation technology. The prenatal diagnostic procedures were performed by two operators with different experience (beginner: 1 year and expert: 15 years) using FINE and traditional fetal echocardiography. Data were analyzed on the time of examination and acquisition of results. RESULTS: Diagnoses made by FINE and traditional echocardiography were completely consistent with the final diagnosis of CHD in 98 (81.66%) versus 20 (16.66%) (P < 0.001) beginners and 87.50% (n = 105) versus 101 (84.16%) experts, respectively. On the contrary, there was significant difference using traditional echocardiography (16.66% versus 84.16%, P < 0.001) by two examiners. Furthermore, the examination time decreased when using FINE compared with using traditional echocardiography (beginner operators: 4.54 ± 1.03 min versus 20.58 ± 3.36 min, P < 0.001; expert operators: 3.89 ± 0.96 min versus 12.73 ± 1.62 min, P < 0.001). CONCLUSION: Based on our results, a prenatal diagnosis of CHD can be made with high feasibility and accuracy using FINE compared with traditional fetal echocardiography for beginner operators.


Assuntos
Doenças Fetais , Cardiopatias Congênitas , Gravidez , Feminino , Humanos , Ecocardiografia Quadridimensional/métodos , Coração Fetal/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Estudos Prospectivos , Cardiopatias Congênitas/diagnóstico por imagem
5.
Echocardiography ; 39(6): 758-767, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35505628

RESUMO

OBJECTIVE: Echocardiography is a time and cost-effective imaging modality, providing evidence of myocardial ischemia by detecting the regional wall motion abnormalities (RWMA). However, quite a few coronary heart disease (CHD) patients do not present RWMA. The left atrium (LA) plays an irreplaceable role in determining the prognosis and risk stratification of cardiovascular disease including CHD. In this present study, we intend to explore the myocardial mechanics changes of LA mainly using four-dimensional (4D) LA quantitative volume-strain in CHD patients without RWMA at rest but were confirmed by coronary angiography (CAG) and to figure out several variables of the LA that could contribute to the identification of those patients. METHODS: We prospectively enrolled 76 patients who underwent two-dimensional echocardiography (2DE), four-dimensional echocardiography (4DE), and CAG for suspected CHD but without echocardiographic visible RWMA at rest. Patients diagnosed with CHD by CAG were furtherly divided into three groups according to the extent of coronary stenosis accessed by Gensini score (GS) as the mild, moderate, and severe CHD group. Twenty-four subjects with negative CAG results served as the control group. LA end-systolic anteroposterior diameter (LAAPD) and biplane LV ejection fraction (Biplane LVEF) were measured by 2DE; LA maximum volume (LAVmax), LA minimum volume (LAVmin), LA volume at the onset of atrial contraction (LAVpreA), LAVmax index (LAVmaxI), LA ejection volume (LAEV), LA ejection fraction (LAEF) accompanied by LA longitudinal strain during reservoir phase (LASr), conduit phase (LAScd), contraction phase (LASct) and LA circumferential strain during reservoir phase (LASr_c), conduit phase (LAScd_c), contraction phase (LASct_c) were measured by 4DE automatically. We compared these parameters between groups, explored how they change and whether they are related to the CHD severity. RESULTS: LAEF, LASr_c, and LASct_c was lower in CHD group compared with the control group (p = .031, .002, .004, respectively). Pearson correlation analysis showed that LASr, LASct, LASr_c, and LASct_c negatively correlated with the GS. Additionally, LASr of patients in the severe CHD group decreased significantly compared with those in the mild CHD group, moderate CHD group, and control group, demonstrating the highest area under the receiver operating characteristic (ROC) curve (AUC) (AUC = .736 [p = .003, 95% CI .589-.884], sensitivity 67.8%, specificity 70.6%) with the cut-off value of 17.5% for predicting severe CHD patients. CONCLUSION: Four-dimensional LA strain may provide new insight into identification and management for CHD patients and correlate with CHD severity. LASr showed good sensitivity (67.8%) and specificity (70.6%) for diagnosing severe CHD individuals.


Assuntos
Função do Átrio Esquerdo , Estenose Coronária , Estenose Coronária/complicações , Estenose Coronária/diagnóstico por imagem , Ecocardiografia Quadridimensional , Átrios do Coração/diagnóstico por imagem , Humanos , Volume Sistólico
6.
Fetal Pediatr Pathol ; 41(2): 346-350, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32815432

RESUMO

BackgroundFetal echocardiography continues to be the first line investigation for detecting congenital heart diseases (CHD). As accurate and complete diagnosis of complex heart disease is often difficult in the first trimester due to small size of the fetal heart, confirmation/expanded description by fetopsy provides the best information for accurate counseling for future pregnancies. Although non invasive fetal autopsy alternatives have been investigated with favorable results, conventional autopsy remains the gold standard procedure used to confirm the fetal abnormalities. Case report: We describe a conotruncal anomaly diagnosed at 12 weeks gestation using spatiotemporal image. The fetopsy confirmed the diagnosis of Type I Truncus arteriosus. Conclusion: Four-dimensional STIC imaging provides incremental benefits in evaluation of fetal cardiac anomalies, and confirmation by autopsy findings allows further refinement of the diagnosis.


Assuntos
Ecocardiografia Quadridimensional , Cardiopatias Congênitas , Autopsia , Ecocardiografia Quadridimensional/métodos , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Gravidez , Primeiro Trimestre da Gravidez , Diagnóstico Pré-Natal , Ultrassonografia Pré-Natal/métodos
7.
J Matern Fetal Neonatal Med ; 35(7): 1310-1317, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32295436

RESUMO

OBJECTIVES: Recent advances in Spatial Temporal Image Correlation (STIC) 4 D fetal echocardiography include the application of eSTIC based on electronic probe image acquisition. We aimed to directly compare the performance of conventional STIC versus eSTIC technique (B-Mode and color Doppler imaging) during off-line reconstruction of STIC/eSTIC fetal heart volume pairs. METHODS: Pairs of B-Mode and Color Doppler STIC volumes were acquired sequentially by firstly conventional (STIC) followed by electronic (eSTIC) probes during 33 consecutive obstetric scans at median 23 (range 13-31) gestational weeks. The resulting 66 fetal heart volume pairs were assessed blindly off-line by a fetal cardiologist who documented feasibility of reconstruction, presence of motion artifacts, subjective image quality on a 4-level scale: 1-best to 4-non-diagnostic and morphological diagnosis, to enable a paired comparison of STIC and eSTIC in the same fetus under similar scanning conditions. RESULTS: eSTIC volumes had higher temporal resolution (37 vs. 24 frames per second, p < .001), less motion during acquisition (12 vs. 20 cases, O.R. 7.0, p = .002) and better average image quality (1.9 vs. 2.2, p = .006) compared to STIC volumes. More diagnostic reconstructions were achieved by eSTIC (n = 55, 86%) than STIC (n = 52, 78.8%), p = .001), in a comparable analysis time (mean 4.96 vs. 4.94 min). During a comparison of image quality of the original acquisition (A) and reconstructed planes (B and C planes) e STIC was superior in 22 (33%), 39 (59%) and 21 (38%) volumes, respectively, with the remaining cases being of similar quality (<10% in each plane in favor of STIC). Imaging mode and gestational age had a similar impact on both eSTIC and STIC performance: diagnostically acceptable studies in 49 (75.8%) vs. 48 (72.2%) by B-Mode, 60 (90.9%) vs. 56 (84.8%) by Color Doppler Mode, 8 (62.5%) vs. 10 (50%) in early scans, 38 (95%) vs. 38 (95%) in mid-gestation scans, and 7 (70%) vs. 6 (60%) in third trimester scans. Eight obstetric scans identified a fetus with a cardiac variant or structural abnormality. Diagnostic concordance of the two STIC approaches was comparable (40/48 concordant interpretations, kappa 0.657) all confirmed by fetal and/or postnatal echocardiography. CONCLUSIONS: eSTIC was associated with more effective 4 D fetal heart reconstruction due to reduced motion artifacts and superior image quality in all planes, when compared to STIC. Early gestation reconstructions were not generally successful using either technology. Further study is needed to define the cost-effectiveness and diagnostic impact of eSTIC over conventional STIC and their role over, or in addition to, screening 2 D fetal echocardiography by appropriately trained sonographers.


Assuntos
Cardiopatias Congênitas , Ultrassonografia Pré-Natal , Ecocardiografia Quadridimensional/métodos , Eletrônica , Feminino , Coração Fetal/diagnóstico por imagem , Idade Gestacional , Humanos , Gravidez , Ultrassonografia Pré-Natal/métodos
8.
J Matern Fetal Neonatal Med ; 35(8): 1498-1516, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32375528

RESUMO

Congenital heart disease (CHD) is the leading organ-specific birth defect, as well as the leading cause of infant morbidity and mortality from congenital malformations. Therefore, a comprehensive screening examination of the fetal heart should be performed in all women to maximize the detection of CHD. Four-dimensional sonography with spatiotemporal image correlation (STIC) technology displays a cine loop of a complete single cardiac cycle in motion. A novel method known as Fetal Intelligent Navigation Echocardiography (or FINE) was previously developed to interrogate STIC volume datasets using "intelligent navigation" technology. Such method allows the automatic display of nine standard fetal echocardiography views required to diagnose most cardiac defects. FINE considerably simplifies fetal cardiac examinations and reduces operator dependency. It has both high sensitivity and specificity for the detection of CHD. Indeed, FINE has been integrated into several commercially available ultrasound platforms.Recently, eight novel and advanced features have been developed for the FINE method and they will be described herein. Such features can be categorized based upon their broad goals. The first goal is to simplify FINE further, and consists of the following features: (1) Auto fetal positioning (or FINE align); (2) Skip points; (3) Predictive cursor; (4) Static mode volume; and (5) Breech sweep. The second goal is to allow quantitative measurements to be performed on the cardiac views generated by FINE: (6) Automatic cardiac axis; and (7) Cardiac biometry. Finally, the last goal is to improve the success of obtaining fetal echocardiography view(s); and consists of (8) Maestro planar navigation.


Assuntos
Cardiopatias Congênitas , Ultrassonografia Pré-Natal , Biometria , Ecocardiografia/métodos , Ecocardiografia Quadridimensional/métodos , Feminino , Coração Fetal/anormalidades , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Gravidez , Ultrassonografia Pré-Natal/métodos
9.
J Matern Fetal Neonatal Med ; 35(14): 2678-2683, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32693651

RESUMO

The incidence of bilateral ductus arteriosus is sporadically reported in the uterus, and right aortic arch with aberrant of the left subclavian artery in association with bilateral ductus arteriosus is therefore extremely rare. We describe a case of right aortic arch and aberrant left subclavian artery associated with bilateral ductus arteriosus. Scanning around the three-vessel and trachea view to search for an "O" shape and a "U" shape vascular ring is essential for the diagnosis, which reveals vascular structures coursing around the trachea. Four-dimensional echocardiography with high-definition flow imaging and spatiotemporal image correlation technique illustrates the spatial relationships of these vessels and the trachea, which should be considered as a complementary modality in fetal cardiac examinations.


Assuntos
Permeabilidade do Canal Arterial , Canal Arterial , Anel Vascular , Aorta Torácica/diagnóstico por imagem , Anormalidades Cardiovasculares , Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/complicações , Permeabilidade do Canal Arterial/diagnóstico por imagem , Ecocardiografia Quadridimensional , Feminino , Humanos , Gravidez , Diagnóstico Pré-Natal , Artéria Subclávia/anormalidades , Artéria Subclávia/diagnóstico por imagem , Anel Vascular/complicações , Anel Vascular/diagnóstico por imagem
10.
Int J Cardiovasc Imaging ; 38(2): 319-329, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34545461

RESUMO

Functional analysis of the fetal cardiovascular system is crucial for the assessment of fetal condition. Evaluation of the right ventricle with standard 2D echocardiography is challenging due to its complex geometry and irregular muscle fibers arrangement. Software package TOMTEC 4D RV-Function is an analysis tool which allows assessment of right ventricular function based on volumetric measurements and myocardial deformation. The aim of this study was to determine the feasibility of this method in fetal echocardiography. The retrospective study was conducted in the high-flow Referral Center for Fetal Cardiology. We recorded 4D echocardiographic sequences of 46 fetuses with normal hearts. Following parameters were calculated: end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF), right ventricle longitudinal free-wall (RVLS free-wall) and septal strain (RVLS septum). Tei index was calculated as a standard measure or RV function for comparison. 4D assessment was feasible in 38 out of 46 fetuses (83%). RV volumetric parameters-EDV, ESV and SV-increased exponentially with gestational age. Functional parameters-RV Tei index, EF and strains-were independent of gestational age. Mean EF was 45.2% (± 6%), RV free-wall strain was - 21.2% and RV septal strain was - 21.5%. There was a statistically significant correlation between septal and free-wall strains (r = 0.51, p = 0.001) as well as between EF and RV free-wall strain (r = - 0.41, p = 0.011). 4D RV assessment is feasible in most fetuses. Its clinical application should be further investigated in larger prospective studies.


Assuntos
Ventrículos do Coração , Disfunção Ventricular Direita , Ecocardiografia Quadridimensional , Estudos de Viabilidade , Feto , Ventrículos do Coração/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Direita
11.
J Clin Ultrasound ; 50(2): 198-200, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34398457

RESUMO

Interrupted aortic arch (IAA) is a rare complex congenital heart disease characterized by interrupted continuity between ascending aorta and descending aorta. Prenatal diagnosis of IAA by echocardiography is not uncommonly reported despite its rarity. However, employing four-dimensional ultrasound HD-flow imaging and spatiotemporal image correlation (STIC) in diagnosis of this condition has seldom been reported. We report a case of fetal IAA prenatally diagnosed by two-dimensional echocardiography and HD-flow STIC.


Assuntos
Ecocardiografia Quadridimensional , Cardiopatias Congênitas , Aorta Torácica/diagnóstico por imagem , Feminino , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Gravidez , Diagnóstico Pré-Natal , Ultrassonografia Pré-Natal
12.
Eur Heart J Cardiovasc Imaging ; 24(1): 152-161, 2022 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-34964463

RESUMO

AIMS: Left atrial (LA) fibrosis is a hallmark of atrial cardiomyopathy, and non-invasive surrogate measures of LA fibrosis are therefore needed. We investigated the association between four-dimensional (4D) echocardiographic LA measures and LA fibrosis. METHODS AND RESULTS: A multimodality imaging substudy was performed in a randomized clinical trial (LOOP study), recruiting elderly participants with cardiovascular risk factors. LA late gadolinium enhancement (LGE) by cardiac magnetic resonance imaging was used as a surrogate for LA fibrosis. 4D echocardiographic LA quantification was used to measure maximal and minimal LA volume (LAVmax and LAVmin, respectively), LA emptying fractions (LAEFtotal), and strain. Logistic regression was used to relate LA measures to high LA LGE (≥17 cm2). Of the 44 participants (mean age 76 years, 64% men, median LA LGE 13.1 cm2), 14 exhibited high LA LGE. These participants exhibited abnormalities in several LA functional measures but not LAVmax. In linear regressions, only increasing LAVmin, and decreasing LAEFtotal, and reservoir strain were associated with increasing LA LGE. Furthermore, increasing LAVmin was associated with a higher likelihood of high LA LGE [odds ratio (OR) = 1.19 (1.04-1.37)]. Decreasing LAEFtotal and reservoir strain were also associated with higher likelihood of LA LGE [OR = 1.18 (1.05-1.33)] and OR = 1.15 (1.02-1.30), per 1% decrease in LAEFtotal and reservoir strain, respectively]. These findings were consistent after multivariable adjustments. LAEFtotal provided the highest performance for detecting high LA LGE (area under the curve of 0.78). CONCLUSION: LAVmin, LAEFtotal, and reservoir strain measured by 4D echocardiography are significantly associated with LA LGE. LAEFtotal provides the best performance for detecting high LA LGE.


Assuntos
Fibrilação Atrial , Masculino , Humanos , Idoso , Feminino , Meios de Contraste , Gadolínio , Ecocardiografia Quadridimensional , Átrios do Coração/diagnóstico por imagem , Fibrose
13.
Ultrasound Obstet Gynecol ; 60(2): 284-290, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34687572

RESUMO

Ductal origin of distal pulmonary artery (DODPA) is a rare congenital cardiovascular anomaly, with an incidence of approximately 1 in 200 000 people. It involves the proximal interruption of one pulmonary artery branch, with the distal part arising from the base of the brachiocephalic artery, via the ipsilateral ductus arteriosus (DA) and the intrapulmonary branch of the pulmonary artery is usually intact. If timely treatment is not provided after birth, it is very likely that, due to DA closure, severe hypoplasia will occur in the lung supplied by the abnormal pulmonary artery. Hence, prenatal diagnosis of DODPA is important to enable initiation of prostaglandin treatment and early rehabilitation of the affected lung. Herein, we report three cases of fetal DODPA diagnosed via two-dimensional (2D) ultrasonography combined with four-dimensional (4D) spatiotemporal image correlation. We also present a literature review, and explore the ultrasonographic findings and the importance of 2D and 4D ultrasonography in obtaining an accurate prenatal diagnosis of DODPA. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Canal Arterial , Ecocardiografia Quadridimensional , Canal Arterial/diagnóstico por imagem , Ecocardiografia Quadridimensional/métodos , Feminino , Humanos , Gravidez , Diagnóstico Pré-Natal , Artéria Pulmonar/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos
14.
Echocardiography ; 38(8): 1430-1445, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34232534

RESUMO

Attempting a comprehensive examination of the fetal heart remains challenging for unexperienced operators as it emphasizes the acquisition and documentation of sequential cross-sectional and sagittal views and inevitably results in diminished detection rates of fetuses affected by congenital heart disease. The introduction of four-dimensional spatio-temporal image correlation (4D STIC) technology facilitated a volumetric approach for thorough cardiac anatomic evaluation by the acquisition of cardiac 4D datasets. By analyzing and re-arranging of numerous frames according to their temporal event within the heart cycle, STIC allows visualization of cardiac structures as an endless cine loop sequence of a complete single cardiac cycle in motion. However, post-analysis with manipulation and repeated slicing of the volume usually requires experience and in-depth anatomic knowledge, which limits the widespread application of this advanced technique in clinical care and unfortunately leads to the underestimation of its diagnostic value to date. Fetal intelligent navigation echocardiography (FINE), a novel method that automatically generates and displays nine standard fetal echocardiographic views in normal hearts, has shown to be able to overcome these limitations. Very recent data on the detection of congenital heart defects (CHDs) using the FINE method revealed a high sensitivity and specificity of 98% and 93%, respectively. In this two-part manuscript, we focused on the performance of FINE in delineating abnormal anatomy of typical right and left heart lesions and thereby emphasized the educational potential of this technology for more than just teaching purposes. We further discussed recent findings in a pathophysiological and/or functional context.


Assuntos
Ecocardiografia Quadridimensional , Cardiopatias Congênitas , Estudos Transversais , Feminino , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Gravidez , Ultrassonografia Pré-Natal
15.
Am J Physiol Heart Circ Physiol ; 321(1): H197-H207, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34085843

RESUMO

Mouse models of cardiac disease have become essential tools in the study of pathological mechanisms, but the small size of rodents makes it challenging to quantify heart function with noninvasive imaging. Building off recent developments in high-frequency four-dimensional ultrasound (4DUS) imaging, we have applied this technology to study cardiac dysfunction progression in a murine model of metabolic cardiomyopathy. Cardiac knockout of carnitine palmitoyltransferase 2 (Cpt2M-/-) in mice hinders cardiomyocyte bioenergetic metabolism of long-chain fatty acids, and leads to progressive cardiac hypertrophy and heart failure. The proposed analysis provides a standardized approach to measure localized wall kinematics and simultaneously extracts metrics of global cardiac function, LV morphometry, regional circumferential strain, and regional longitudinal strain from an interpolated 4-D mesh of the endo- and epicardial boundaries. Comparison of metric changes due to aging suggests that circumferential strain at the base and longitudinal strain along the posterior wall are most sensitive to disease progression. We further introduce a novel hybrid strain index (HSI) that incorporates information from these two regions and may have greater utility to characterize disease progression relative to other extracted metrics. Potential applications to additional disease models are discussed that could further demonstrate the utility of metrics derived from 4DUS imaging and strain mapping.NEW & NOTEWORTHY High-frequency four-dimensional ultrasound can be used in conjunction with standardized analysis procedures to simultaneously extract left-ventricular global function, morphometry, and regional strain metrics. Furthermore, a novel hybrid strain index (HSI) formula demonstrates greater performance compared with all other metrics in characterizing disease progression in a model of metabolic cardiomyopathy.


Assuntos
Cardiomegalia/diagnóstico por imagem , Ecocardiografia Quadridimensional/métodos , Coração/diagnóstico por imagem , Animais , Cardiomegalia/genética , Carnitina O-Palmitoiltransferase/genética , Feminino , Camundongos , Camundongos Knockout , Função Ventricular Esquerda/fisiologia
16.
Echocardiography ; 38(5): 777-789, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33778977

RESUMO

Volume ultrasound has been shown to provide valid complementary information on fetal anatomy. Four-dimensional assessment (4D) of the fetal cardiovascular system using spatial-temporal image correlation (STIC) allows for detailed examination of a highly complex organ from the early second trimester onward. There is compelling evidence that this technique harbors quite a number of diagnostic opportunities, but manual navigation through STIC volume datasets is highly operator dependent. In fact, STIC is not incorporated yet into daily practice. Application of the novel fetal intelligent navigation echocardiography (FINE) considerably simplifies fetal cardiac volumetric examinations. This automatic technique applied on cardiac volume datasets reportedly has both high sensitivity and specificity for the detection of congenital heart defects (CHDs). Part I reviewed current data regarding detection rates of CHDs and illustrated the additional value of an automatic approach in delineating cardiac anatomy exemplified by congenital lesions of the right heart. In part II of this pictorial essay, we focused on left heart anomalies and aimed to tabulate recent findings on the quantification of normal and abnormal cardiac anatomy.


Assuntos
Coração Fetal , Cardiopatias Congênitas , Ecocardiografia , Ecocardiografia Quadridimensional , Feminino , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Gravidez , Segundo Trimestre da Gravidez , Ultrassonografia Pré-Natal
17.
Medicine (Baltimore) ; 100(8): e24912, 2021 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-33663125

RESUMO

RATIONALE: Right atrial isomerism (RAI) is one of the most severe forms of congenital heart disease. This case of RAI was so complex that it incorporated 7 heart defects. It can be challenging to display the spatial relationship between different anatomical structures using conventional two-dimensional and color ultrasound (2D-Doppler imaging); therefore, we used spatio-temporal image correlation (STIC) and high definition live flow imaging technology to vividly display this case of RAI in a stereoscopic mode. PATIENT CONCERNS: A 24-year-old woman was referred to our tertiary center at 24 weeks of gestation. The woman had difficult conceiving. Once pregnant, she was opposed to abortion, even if there was a possibility of deformity. DIAGNOSIS: The fetus presented with an atrioventricular septal defect, persistent left superior vena cava, supra-cardiac total anomalous pulmonary venous connection (TAPVC), double outlet right ventricle, right ductus arteriosus, right aortic arch (RAA) with mirror image branching, and aortic arch dysplasia. INTERVENTIONS: After consulting a pediatric cardiologist, the woman requested an abortion and consented to an autopsy. OUTCOMES: Autopsy supported the echocardiographic findings. LESSONS: Accurate diagnosis of RAI is essential for clinical and parent decision making. 2D-Doppler imaging combined with STIC-HD live flow can be used to visualize the spatial morphology of blood vessels, including the cardiac chambers and great vessels of the fetal heart, and smaller peripheral vessels.


Assuntos
Ecocardiografia Quadridimensional/métodos , Coração Fetal/diagnóstico por imagem , Síndrome de Heterotaxia/diagnóstico por imagem , Aborto Eugênico , Autopsia , Feminino , Coração Fetal/patologia , Síndrome de Heterotaxia/patologia , Humanos , Gravidez , Ultrassonografia Pré-Natal
18.
Cardiovasc Ultrasound ; 19(1): 11, 2021 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-33509197

RESUMO

BACKGROUND: The purpose of this study is to evaluate the feasibility using real-time four-dimensional (RT 4D) volume imaging with electronic matrix probe to observe the morphology of atrioventricular valves in normal and abnormal fetuses, measure the area and circumference of atrioventricular valves in normal fetuses and analyze the correlation with gestational age. METHODS: RT 4D volume imaging with electronic matrix probe was used to collect cardiac volume data of 162 normal fetuses with the gestational age from 22 to 32 weeks and 19 fetuses with atrioventricular valves abnormalities were also enrolled. All the volume data were analyzed and processed in real-time. The morphology of mitral and tricuspid valves was observed in surface mode. The area and circumference of valves were measured in a 4D render view at the end of diastole and analyzed the correlation with gestational age. RESULTS: In 148 of 162 fetuses (91%), the 4D rendered image could be successfully obtained, which clearly showed the morphology of the atrioventricular valves. The area and circumference of mitral and tricuspid valves were positively correlated with gestational age (P < 0.01). Furthermore, 4D rendered images were successfully obtained in 17 of 19 fetuses (89%) with atrioventricular valves abnormalities. CONCLUSIONS: The reference range of the area and circumference of atrioventricular valves in normal fetuses at different gestational weeks could be determined by using the RT 4D volume imaging with electronic matrix probe, which can provide certain diagnostic information for the clinic. The RT 4D images could display the valves morphology vividly in both normal and abnormal fetuses, including some subtle lesions which are not identified by traditional two-dimensional (2D) echocardiography. It is feasible to use the RT 4D volume imaging with electronic matrix probe to perform the prenatal evaluation in the fetal atrioventricular valves.


Assuntos
Ecocardiografia Quadridimensional , Ultrassonografia Pré-Natal , Eletrônica , Feminino , Feto , Idade Gestacional , Humanos , Lactente , Gravidez
19.
Ultrasound Obstet Gynecol ; 57(3): 423-430, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32022380

RESUMO

OBJECTIVE: To analyze the incremental benefit of 3D/4D spatiotemporal image correlation (STIC) fetal echocardiography over 2D fetal echocardiography with respect to the accuracy of identification of anatomic details crucial for surgical decision-making and in predicting surgical approach in fetuses with double-outlet right ventricle (DORV). METHODS: This was a retrospective study of fetuses with DORV which had undergone both 2D echocardiography and 3D/4D STIC echocardiography and which underwent surgery postnatally in a tertiary pediatric cardiac center in Kerala between October 2015 and March 2019. All such cases with normal atrial arrangement, concordant atrioventricular connections and balanced ventricles were included. 2D and 3D/4D STIC fetal echocardiographic data were analyzed by two experienced observers blinded to the other dataset. Anatomic variables crucial for surgical decision-making, i.e. location and routability of the ventricular septal defect, relationship of the great arteries and presence of outflow obstruction, were compared between the two modalities with respect to agreement with postnatal echocardiography. The accuracy of prenatal prediction of the surgical pathway was compared between 2D and 3D/4D modalities with respect to the procedure undertaken. RESULTS: Included in the study were 22 fetuses with DORV which had undergone both 2D and 3D/4D imaging as well as postnatal surgery. Accuracy of prenatal interpretation of all four anatomic variables was significantly higher using 3D/4D STIC than using 2D fetal echocardiography (19/22 (86.4%) vs 8/22 (36.4%), P < 0.001). Surgical procedures included single-stage repair in 14 (63.5%) patients and a multistage approach in eight (36.4%). Prenatal prediction of the surgical pathway was significantly more accurate on 3D/4D STIC than on 2D echocardiography (20/22 (90.9%) vs 12/22 (54.5%), P = 0.021). Prenatal predictive accuracy of single-stage biventricular repair was significantly better for 3D/4D STIC than for 2D echocardiography (14/14 (100%) vs 8/14 (57.1%), P = 0.04). CONCLUSION: Addition of 3D/4D STIC to conventional 2D fetal echocardiography confers incremental benefit on the accuracy of identification of anatomic details crucial for surgical decision-making and the prediction of postnatal surgical approach in fetuses with DORV, thereby potentially aiding prenatal counseling. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Dupla Via de Saída do Ventrículo Direito/diagnóstico por imagem , Ecocardiografia Quadridimensional/estatística & dados numéricos , Ecocardiografia Tridimensional/estatística & dados numéricos , Coração Fetal/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Adulto , Procedimentos Cirúrgicos Cardíacos/métodos , Dupla Via de Saída do Ventrículo Direito/embriologia , Dupla Via de Saída do Ventrículo Direito/cirurgia , Feminino , Coração Fetal/embriologia , Coração Fetal/cirurgia , Humanos , Recém-Nascido , Valor Preditivo dos Testes , Gravidez , Estudos Retrospectivos
20.
Cardiovasc Toxicol ; 21(3): 216-223, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33068232

RESUMO

Tyrosine kinase inhibitors (TKIs) are established treatment for haematological malignancies. However, cardiac adverse effects, including the reduction in left ventricular ejection fraction and symptomatic heart failure remain clinical problems. The purpose of this study was to evaluate the left ventricular systolic functions in patients with chronic myeloid leukaemia receiving TKIs. A cross-sectional and observational study was conducted of 37 patients with chronic myeloid leukaemia receiving dasatinib or nilotinib after imatinib failure. Left ventricular systolic functions were evaluated using four-dimensional speckle tracking echocardiography derived global longitudinal (GLS), circumferential (GCS), radial (GRS), and area (GAS) strain indices. Mean ejection fraction, stroke volume, cardiac output and left ventricular mass index were similar between control and patient groups and within normal limits. GLS (- 16.7% vs - 20.8%, p < 0.001), GCS (- 13.0% vs - 15.6%, p = 0.002), and GAS (- 26.2% vs - 31.0, p < 0.001) values were significantly higher in the patient population than those of the controls. Dasatinib and nilotinib groups did not show differences regarding strain indices. In multivariate regression analysis, only the usage of dasatinib or nilotinib was found to be an independent risk factor for diminished GAS (ß = 4.406, p = 0.016), GLS (ß = 3.797, p = 0.001), and GCS (ß = 2.404, p = 0.040). Although imatinib, nilotinib, and dasatinib seem to be clinically safe in terms of cardiac function, monitoring of systolic functions using strain imaging, and long-term observation of patients may provide early detection of the possible cardiac toxicity.


Assuntos
Antineoplásicos/efeitos adversos , Ecocardiografia Quadridimensional , Leucemia Mielogênica Crônica BCR-ABL Positiva/tratamento farmacológico , Inibidores de Proteínas Quinases/efeitos adversos , Proteínas Tirosina Quinases/antagonistas & inibidores , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda/efeitos dos fármacos , Adulto , Idoso , Cardiotoxicidade , Estudos Transversais , Dasatinibe/efeitos adversos , Diagnóstico Precoce , Feminino , Humanos , Mesilato de Imatinib/efeitos adversos , Leucemia Mielogênica Crônica BCR-ABL Positiva/diagnóstico , Leucemia Mielogênica Crônica BCR-ABL Positiva/enzimologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Proteínas Tirosina Quinases/metabolismo , Pirimidinas/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Sístole , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/induzido quimicamente , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA