Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76.532
Filtrar
1.
J Vis Exp ; (206)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38738884

RESUMO

Intricate interactions between multiple brain areas underlie most functions attributed to the brain. The process of learning, as well as the formation and consolidation of memories, are two examples that rely heavily on functional connectivity across the brain. In addition, investigating hemispheric similarities and/or differences goes hand in hand with these multi-area interactions. Electrophysiological studies trying to further elucidate these complex processes thus depend on recording brain activity at multiple locations simultaneously and often in a bilateral fashion. Presented here is a 3D-printable implant for rats, named TD Drive, capable of symmetric, bilateral wire electrode recordings, currently in up to ten distributed brain areas simultaneously. The open-source design was created employing parametric design principles, allowing prospective users to easily adapt the drive design to their needs by simply adjusting high-level parameters, such as anterior-posterior and mediolateral coordinates of the recording electrode locations. The implant design was validated in n = 20 Lister Hooded rats that performed different tasks. The implant was compatible with tethered sleep recordings and open field recordings (Object Exploration) as well as wireless recording in a large maze using two different commercial recording systems and headstages. Thus, presented here is the adaptable design and assembly of a new electrophysiological implant, facilitating fast preparation and implantation.


Assuntos
Sono , Animais , Ratos , Sono/fisiologia , Eletrodos Implantados , Encéfalo/fisiologia , Eletrofisiologia/métodos , Eletrofisiologia/instrumentação , Impressão Tridimensional , Comportamento Animal/fisiologia , Fenômenos Eletrofisiológicos , Masculino
2.
Ying Yong Sheng Tai Xue Bao ; 35(3): 858-866, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38646774

RESUMO

Insect visual electrophysiological techniques are important to study the electrical characteristics of photoreceptor cells and visual neurons in insects, including electroretinography (ERG) and microelectrode intracellular recording (MIR). ERG records the changes of voltage or electric current in the retina of insects in response to different light stimuli, which occurs outside the cell. MIR records the changes in individual photoreceptor cells or visual neurons of an insect exposed to different lights, which occurs inside the cell. Insect visual electrophysiological techniques can explore the mechanism of electrophysiological response of insects' vision to light and reveal their sensitive light spectra and photoreceptor types. This review introduced the basic structure and the principle of ERG and MIR, and summarized their applications in insect researches in the past 20 years, which would provide references for elucidating the mechanism of light perception in insects and the use of insect phototropism to control pests.


Assuntos
Eletrorretinografia , Insetos , Células Fotorreceptoras de Invertebrados , Animais , Insetos/fisiologia , Eletrorretinografia/métodos , Células Fotorreceptoras de Invertebrados/fisiologia , Visão Ocular/fisiologia , Microeletrodos , Fenômenos Eletrofisiológicos , Eletrofisiologia/métodos
3.
Methods Mol Biol ; 2757: 307-313, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38668974

RESUMO

Pelagic ctenophores swim in the water with the help of eight rows of long fused cilia. Their entire behavioral repertoire is dependent to a large degree on coordinated cilia activity. Therefore, recording cilia beating is paramount to understanding and registering the behavioral responses and investigating its neural and hormonal control. Here, we present a simple protocol to monitor and quantify cilia activity in semi-intact ctenophore preparations (using Pleurobrachia and Bolinopsis as models), which includes a standard electrophysiological setup for intracellular recording.


Assuntos
Cílios , Ctenóforos , Cílios/fisiologia , Animais , Ctenóforos/fisiologia , Eletrofisiologia/métodos , Fenômenos Eletrofisiológicos
4.
Methods Mol Biol ; 2757: 315-359, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38668975

RESUMO

Unlike in the Cnidaria, where muscle cells are coupled together into an epithelium, ctenophore muscles are single, elongated, intramesogleal structures resembling vertebrate smooth muscle. Under voltage-clamp, these fibers can be separated into different classes with different sets of membrane ion channels. The ion channel makeup is related to the muscle's anatomical position and specific function. For example, Beroe ovata radial fibers, which are responsible for maintaining the rigidity of the body wall, generate sequences of brief action potentials whereas longitudinal fibers, which are concerned with mouth opening and body flexions, often produce single longer duration action potentials.Beroe muscle contractions depend on the influx of Ca2+. During an action potential the inward current is carried by Ca2+, and the increase in intracellular Ca2+ concentration generated can be monitored in FLUO-3-loaded cells. Confocal microscopy in line scan mode shows that the Ca2+ spreads from the outer membrane into the core of the fiber and is cleared from there relatively slowly. The rise in intracellular Ca2+ is linked to an increase in a Ca2+-activated K+ conductance (KCa), which can also be elicited by iontophoretic Ca2+ injection. Near the cell membrane, Ca2+ clearance monitored using FLUO3, matches the decline in the KCa conductance. For light loads, Ca2+ is cleared rapidly, but this fast system is insufficient when Ca2+ influx is maintained. Action potential frequency may be regulated by the slowly developing KCa conductance.


Assuntos
Cálcio , Ctenóforos , Músculo Liso , Animais , Músculo Liso/fisiologia , Músculo Liso/metabolismo , Cálcio/metabolismo , Ctenóforos/fisiologia , Técnicas de Patch-Clamp/métodos , Potenciais de Ação/fisiologia , Contração Muscular/fisiologia , Fenômenos Eletrofisiológicos , Eletrofisiologia/métodos , Microscopia Confocal
6.
Methods Enzymol ; 696: 109-154, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38658077

RESUMO

The use of molecular dynamics (MD) simulations to study biomolecular systems has proven reliable in elucidating atomic-level details of structure and function. In this chapter, MD simulations were used to uncover new insights into two phylogenetically unrelated bacterial fluoride (F-) exporters: the CLCF F-/H+ antiporter and the Fluc F- channel. The CLCF antiporter, a member of the broader CLC family, has previously revealed unique stoichiometry, anion-coordinating residues, and the absence of an internal glutamate crucial for proton import in the CLCs. Through MD simulations enhanced with umbrella sampling, we provide insights into the energetics and mechanism of the CLCF transport process, including its selectivity for F- over HF. In contrast, the Fluc F- channel presents a novel architecture as a dual topology dimer, featuring two pores for F- export and a central non-transported sodium ion. Using computational electrophysiology, we simulate the electrochemical gradient necessary for F- export in Fluc and reveal details about the coordination and hydration of both F- and the central sodium ion. The procedures described here delineate the specifics of these advanced techniques and can also be adapted to investigate other membrane protein systems.


Assuntos
Bioquímica , Biologia Computacional , Fluoretos , Simulação de Dinâmica Molecular , Fluoretos/metabolismo , Proteínas de Membrana Transportadoras/metabolismo , Transporte de Íons/fisiologia , Canais de Cloreto/química , Canais de Cloreto/metabolismo , Eletrofisiologia , Bioquímica/métodos , Biologia Computacional/métodos , Proteínas de Bactérias/química , Proteínas de Bactérias/metabolismo , Transporte Biológico Ativo/fisiologia
7.
J Pharmacol Toxicol Methods ; 126: 107496, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38432527

RESUMO

An adverse effect of drug candidates, seizure is a serious issue in drug development. Improving evaluation systems for seizure liability is crucial for selecting good candidates. Firstly, in vitro electrophysiological measurement by a multielectrode array system in rat hippocampal brain slices was employed to confirm an increase in electrically evoked population spike (PS) area, the occurrence of multiple population spikes (MPSs), and thereby the seizure liability of five positive control chemicals: picrotoxin, 4-aminopyridine, pentylenetetrazole, penicillin G, and chlorpromazine. Aspirin, a negative control, did not affect PS area or generate MPSs. Furthermore, baclofen, an anticonvulsant drug, decreased PS area and inhibited the increase in PS area or occurrence of MPSs induced by picrotoxin. A comparative study of seizure liability among carbapenem antibiotics revealed that tienam > carbenin > omegacin and finibax. Despite leading to a strong decrease in PS area, physostigmine, cisplatin, and paroxetine still produced MPSs. Therefore, the increase in PS area or the occurrence of the MPS are considered significant evaluation parameters for seizure liability. In contrast, the in vitro electrophysiological measurement could not detect the seizure liability of diphenhydramine or fluvoxamine. A follow-up study of in vivo mouse behavioral change induced by intracerebroventricular administration of these drugs clearly detected convulsions. The in vitro electrophysiological study using hippocampal brain slices combined with in vivo behavior observation study of drug candidates administered by intracerebroventricular injection can implement to assess the seizure liability of even small amounts, especially in the early stages of drug development.


Assuntos
Técnicas de Observação do Comportamento , Convulsões , Ratos , Camundongos , Animais , Picrotoxina/efeitos adversos , Seguimentos , Convulsões/induzido quimicamente , Eletrofisiologia , Hipocampo , Encéfalo
8.
Nanoscale ; 16(13): 6402-6428, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38488215

RESUMO

The peripheral nervous and muscular system, a cornerstone of human physiology, plays a pivotal role in ensuring the seamless functioning of the human body. This intricate network, comprising nerves and muscles extending throughout the body, is essential for motor control, sensory feedback, and the regulation of autonomic bodily functions. The qualified implantable peripheral interface can accurately monitor the biopotential of the target tissue and conduct treatment with stimulation, enhancing the human-machine interaction and new achievements in disease cure. Implantable electrodes have revolutionized the field of neuromuscular interfaces, offering precise bidirectional communication between the neuromuscular system and external devices. They enable natural control for individuals with limb loss, bridging the gap between mind and machine and aiding neuromuscular rehabilitation. In research and medical diagnostics, implantable electrodes provide invaluable tools for studying neuromuscular function and the development of therapies. However, traditional rigid electrodes face challenges due to the dynamic nature of the peripheral neuromuscular system. Flexible and stretchable devices show immense promise in accommodating dynamic alterations, offering adaptability, and accurate monitoring of electrophysiological signals. This review delves into the challenges associated with the peripheral interface, primarily focusing on monitoring and stimulation. It then provides a summary of common materials and structural design optimizations, discusses technologies for enhancing interface adhesion and surface functionalization, and explores encapsulation methods for implanted devices. Recent advancements in energy supply and the applications of implantable, flexible, and stretchable devices are also comprehensively reviewed, with due consideration given to ethical concerns and signal analysis. The promising directions are finally presented to provide enlightenment for high-performance sensor-tissue interfaces in the future, which will promote profound progress in clinical and human-machine interaction research. Flexible and stretchable devices are at the forefront of healthcare, with the potential to transform the treatment of neuromuscular disorders and enhance human augmentation, blurring the lines between natural and artificial limbs. They represent a promising avenue for the future, with exciting applications in healthcare, science, and technology, promising to bring us closer to the seamless integration of human and machine in the realm of neuromuscular interfaces.


Assuntos
Membros Artificiais , Dispositivos Eletrônicos Vestíveis , Humanos , Eletrodos Implantados , Eletrofisiologia
9.
J Neurosci ; 44(11)2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38479812

RESUMO

The axon is a neuronal structure capable of processing, encoding, and transmitting information. This assessment contrasts with a limiting, but deeply rooted, perspective where the axon functions solely as a transmission cable of somatodendritic activity, sending signals in the form of stereotypical action potentials. This perspective arose, at least partially, because of the technical difficulties in probing axons: their extreme length-to-diameter ratio and intricate growth paths preclude the study of their dynamics through traditional techniques. Recent findings are challenging this view and revealing a much larger repertoire of axonal computations. Axons display complex signaling processes and structure-function relationships, which can be modulated via diverse activity-dependent mechanisms. Additionally, axons can exhibit patterns of activity that are dramatically different from those of their corresponding soma. Not surprisingly, many of these recent discoveries have been driven by novel technology developments, which allow for in vitro axon electrophysiology with unprecedented spatiotemporal resolution and signal-to-noise ratio. In this review, we outline the state-of-the-art in vitro toolset for axonal electrophysiology and summarize the recent discoveries in axon function it has enabled. We also review the increasing repertoire of microtechnologies for controlling axon guidance which, in combination with the available cutting-edge electrophysiology and imaging approaches, have the potential for more controlled and high-throughput in vitro studies. We anticipate that a larger adoption of these new technologies by the neuroscience community will drive a new era of experimental opportunities in the study of axon physiology and consequently, neuronal function.


Assuntos
Axônios , Neurônios , Axônios/fisiologia , Potenciais de Ação/fisiologia , Fenômenos Eletrofisiológicos , Eletrofisiologia
10.
PLoS One ; 19(3): e0298320, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38483943

RESUMO

BACKGROUND: Deep Brain Stimulation (DBS), applying chronic electrical stimulation of subcortical structures, is a clinical intervention applied in major neurologic disorders. In order to achieve a good clinical effect, accurate electrode placement is necessary. The primary localisation is typically based on presurgical MRI imaging, often followed by intra-operative electrophysiology recording to increase the accuracy and to compensate for brain shift, especially in cases where the surgical target is small, and there is low contrast: e.g., in Parkinson's disease (PD) and in its common target, the subthalamic nucleus (STN). METHODS: We propose a novel, fully automatic method for intra-operative surgical navigation. First, the surgical target is segmented in presurgical MRI images using a statistical shape-intensity model. Next, automated alignment with intra-operatively recorded microelectrode recordings is performed using a probabilistic model of STN electrophysiology. We apply the method to a dataset of 120 PD patients with clinical T2 1.5T images, of which 48 also had available microelectrode recordings (MER). RESULTS: The proposed segmentation method achieved STN segmentation accuracy around dice = 0.60 compared to manual segmentation. This is comparable to the state-of-the-art on low-resolution clinical MRI data. When combined with electrophysiology-based alignment, we achieved an accuracy of 0.85 for correctly including recording sites of STN-labelled MERs in the final STN volume. CONCLUSION: The proposed method combines image-based segmentation of the subthalamic nucleus with microelectrode recordings to estimate their mutual location during the surgery in a fully automated process. Apart from its potential use in clinical targeting, the method can be used to map electrophysiological properties to specific parts of the basal ganglia structures and their vicinity.


Assuntos
Estimulação Encefálica Profunda , Doença de Parkinson , Humanos , Doença de Parkinson/terapia , Doença de Parkinson/cirurgia , Estimulação Encefálica Profunda/métodos , Imageamento por Ressonância Magnética , Microeletrodos , Eletrofisiologia
11.
STAR Protoc ; 5(1): 102909, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38427565

RESUMO

Here, we present a protocol for the fabrication of transparent implantable electrode arrays for integrating optogenetics and electrophysiology. We describe steps for fabricating microelectrodes using the conductive polymer poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate). We then detail procedures for analyzing performance of the electrodes and recording light-evoked neural activities from the transgenic mouse. This protocol utilizes photolithography rather than conventional electrodeposition. For complete details on the use and execution of this protocol, please refer to Cho et al. (2022).1.


Assuntos
Optogenética , Roedores , Camundongos , Animais , Microeletrodos , Eletrodos Implantados , Camundongos Transgênicos , Eletrofisiologia/métodos
12.
Sci Rep ; 14(1): 6031, 2024 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-38472404

RESUMO

The dysfunction of ion channels is a causative factor in a variety of neurological diseases, thereby defining the implicated channels as key drug targets. The detection of functional changes in multiple specific ionic currents currently presents a challenge, particularly when the neurological causes are either a priori unknown, or are unexpected. Traditional patch clamp electrophysiology is a powerful tool in this regard but is low throughput. Here, we introduce a single-shot method for detecting alterations amongst a range of ion channel types from subtle changes in membrane voltage in response to a short chaotically driven current clamp protocol. We used data assimilation to estimate the parameters of individual ion channels and from these we reconstructed ionic currents which exhibit significantly lower error than the parameter estimates. Such reconstructed currents thereby become sensitive predictors of functional alterations in biological ion channels. The technique correctly predicted which ionic current was altered, and by approximately how much, following pharmacological blockade of BK, SK, A-type K+ and HCN channels in hippocampal CA1 neurons. We anticipate this assay technique could aid in the detection of functional changes in specific ionic currents during drug screening, as well as in research targeting ion channel dysfunction.


Assuntos
Canais Iônicos , Neurônios , Eletrofisiologia , Canais Iônicos/metabolismo , Neurônios/metabolismo , Membrana Celular/metabolismo , Transporte de Íons
13.
J Neurosci Methods ; 404: 110079, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38340901

RESUMO

BACKGROUND: Electrophysiological recording with glass electrodes is one of the best techniques to measure membrane potential dynamics and ionic currents of voltage-gated channels in neurons. However, artifactual variability of the biophysical state variables that determine recording quality can be caused by insufficient affinity between the electrode and cell membrane during the recording. NEW METHOD: We introduce a phospholipid membrane coating on glass electrodes to improve intracellular electrophysiology recording quality. Membrane-coated electrodes were prepared with a tip-dip protocol for perforated-patch, sharp-electrode current-clamp, and cell-attached patch-clamp recordings from specific circadian clock neurons in Drosophila. We perform quantitative comparisons based on the variability of functional biophysical parameters used in various electrophysiological methods, and advanced statistical comparisons based on the degree of stationariness and signal-to-noise ratio. RESULTS: Results indicate a dramatic reduction in artifactual variabilities of functional parameters from enhanced stability. We also identify significant exclusions of a statistically estimated noise component in a time series of membrane voltage signals, improving signal-to-noise ratio. COMPARISON WITH EXISTING METHODS: Compared to standard glass electrodes, using membrane-coated glass electrodes achieves improved recording quality in intracellular electrophysiology. CONCLUSIONS: Electrophysiological recordings from Drosophila central neurons can be technically challenging, however, membrane-coated electrodes will possibly be beneficial for reliable data acquisition and improving the technical feasibility of axonal intracellular activities measurements and single-channel recordings. The improved electrical stability of the recordings should also contribute to increased mechanical stability, thus facilitating long-term stable measurements of neural activity. Therefore, it is possible that membrane-coated electrodes will be useful for any model system.


Assuntos
Drosophila , Neurônios , Animais , Eletrodos , Potenciais da Membrana/fisiologia , Neurônios/fisiologia , Eletrofisiologia
14.
Herzschrittmacherther Elektrophysiol ; 35(Suppl 1): 77-82, 2024 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-38411695

RESUMO

The paper presents the history of hope from 1980-1995 to predict the risk of sudden arrhythmic death using electrophysiologic techniques in individual patients. Even if this prediction seems possible in selected highly risk cohorts, many more patients will die in ventricular arrhythmia without fulfilling the criteria. Ultimately, high risk of sudden cardiac death can be predicted in selected patient groups, but not in the majority of patients at risk. It is a history of dashed hope.


Assuntos
Arritmias Cardíacas , Morte Súbita Cardíaca , Humanos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Eletrofisiologia
16.
Nature ; 626(8001): 1066-1072, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38326610

RESUMO

Animals can learn about sources of danger while minimizing their own risk by observing how others respond to threats. However, the distinct neural mechanisms by which threats are learned through social observation (known as observational fear learning1-4 (OFL)) to generate behavioural responses specific to such threats remain poorly understood. The dorsomedial prefrontal cortex (dmPFC) performs several key functions that may underlie OFL, including processing of social information and disambiguation of threat cues5-11. Here we show that dmPFC is recruited and required for OFL in mice. Using cellular-resolution microendoscopic calcium imaging, we demonstrate that dmPFC neurons code for observational fear and do so in a manner that is distinct from direct experience. We find that dmPFC neuronal activity predicts upcoming switches between freezing and moving state elicited by threat. By combining neuronal circuit mapping, calcium imaging, electrophysiological recordings and optogenetics, we show that dmPFC projections to the midbrain periaqueductal grey (PAG) constrain observer freezing, and that amygdalar and hippocampal inputs to dmPFC opposingly modulate observer freezing. Together our findings reveal that dmPFC neurons compute a distinct code for observational fear and coordinate long-range neural circuits to select behavioural responses.


Assuntos
Sinais (Psicologia) , Medo , Vias Neurais , Córtex Pré-Frontal , Aprendizado Social , Animais , Camundongos , Tonsila do Cerebelo/fisiologia , Cálcio/metabolismo , Eletrofisiologia , Medo/fisiologia , Hipocampo/fisiologia , Vias Neurais/fisiologia , Neurônios/fisiologia , Optogenética , Substância Cinzenta Periaquedutal/citologia , Substância Cinzenta Periaquedutal/fisiologia , Estimulação Luminosa , Córtex Pré-Frontal/citologia , Córtex Pré-Frontal/fisiologia , Aprendizado Social/fisiologia , Reação de Congelamento Cataléptica/fisiologia
17.
Int J Cardiol ; 401: 131817, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38307422

RESUMO

BACKGROUND: High-altitude exposure changes the electrical conduction of the heart. However, reports on electrocardiogram (ECG) characteristics and potent prophylactic agents during high-altitude acclimatization and de-acclimatization are inadequate. This study aimed to investigate the effects of ubiquinol on electrophysiology after high-altitude hypoxia and reoxygenation. METHODS: The study was a prospective, randomized, double-blind, placebo-controlled trial. Forty-one participants were randomly divided into two groups receiving ubiquinol 200 mg daily or placebo orally 14 days before flying to high altitude (3900 m) until the end of the study. Cardiopulmonary exercise testing was performed at baseline (300 m), on the third day after reaching high altitude, and on the seventh day after returning to baseline. RESULTS: Acute high-altitude exposure prolonged resting ventricular repolarization, represented by increased corrected QT interval (455.9 ± 23.4 vs. 427.1 ± 19.1 ms, P < 0.001) and corrected Tpeak-Tend interval (155.5 ± 27.4 vs. 125.3 ± 21.1 ms, P < 0.001), which recovered after returning to low altitude. Ubiquinol supplementation shortened the hypoxia-induced extended Tpeak-Tend interval (-7.7 ms, [95% confidence interval (CI), -13.8 to -1.6], P = 0.014), Tpeak-Tend /QT interval (-0.014 [95% CI, -0.027 to -0.002], P = 0.028), and reserved maximal heart rate (11.9 bpm [95% CI, 3.2 to 20.6], P = 0.013) during exercise at high altitude. Furthermore, the decreased resting amplitude of the ST-segment in the V3 lead was correlated with decreased peak oxygen pulse (R = 0.713, P < 0.001) and maximum oxygen consumption (R = 0.595, P < 0.001). CONCLUSIONS: Our results illustrated the electrophysiology changes during high-altitude acclimatization and de-acclimatization. Similarly, ubiquinol supplementation shortened the prolonged Tpeak-Tend interval and reserved maximal heart rate during exercise at high altitude. REGISTRATION: URL: www.chictr.org.cn; Unique identifier: ChiCTR2200059900.


Assuntos
Altitude , Aptidão Cardiorrespiratória , Ubiquinona/análogos & derivados , Humanos , Estudos Prospectivos , Hipóxia , Aclimatação , Eletrofisiologia
19.
Sci Adv ; 10(8): eadj4399, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38381836

RESUMO

Identifying different sleep stages in humans and other mammals has traditionally relied on electroencephalograms. Such an approach is not feasible in certain animals such as invertebrates, although these animals could also be sleeping in stages. Here, we perform long-term multichannel local field potential recordings in the brains of behaving flies undergoing spontaneous sleep bouts. We acquired consistent spatial recordings of local field potentials across multiple flies, allowing us to compare brain activity across awake and sleep periods. Using machine learning, we uncover distinct temporal stages of sleep and explore the associated spatial and spectral features across the fly brain. Further, we analyze the electrophysiological correlates of microbehaviors associated with certain sleep stages. We confirm the existence of a distinct sleep stage associated with rhythmic proboscis extensions and show that spectral features of this sleep-related behavior differ significantly from those associated with the same behavior during wakefulness, indicating a dissociation between behavior and the brain states wherein these behaviors reside.


Assuntos
Fenômenos Fisiológicos do Sistema Nervoso , Sono , Animais , Humanos , Sono/fisiologia , Fases do Sono/fisiologia , Drosophila/fisiologia , Eletrofisiologia , Mamíferos
20.
Circulation ; 149(10): e937-e952, 2024 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-38314551

RESUMO

Disorders of the cardiac rhythm may occur in both the fetus and neonate. Because of the immature myocardium, the hemodynamic consequences of either bradyarrhythmias or tachyarrhythmias may be far more significant than in mature physiological states. Treatment options are limited in the fetus and neonate because of limited vascular access, patient size, and the significant risk/benefit ratio of any intervention. In addition, exposure of the fetus or neonate to either persistent arrhythmias or antiarrhythmic medications may have yet-to-be-determined long-term developmental consequences. This scientific statement discusses the mechanism of arrhythmias, pharmacological treatment options, and distinct aspects of pharmacokinetics for the fetus and neonate. From the available current data, subjects of apparent consistency/consensus are presented, as well as future directions for research in terms of aspects of care for which evidence has not been established.


Assuntos
American Heart Association , Arritmias Cardíacas , Recém-Nascido , Estados Unidos , Criança , Humanos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/tratamento farmacológico , Taquicardia , Feto , Eletrofisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA