Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.229
Filtrar
1.
Environ Res ; 219: 115115, 2023 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-36574794

RESUMO

The incorporation of a spacer among membranes has a major influence on fluid dynamics and performance metrics. Spacers create feed channels and operate as turbulence promoters to increase mixing and reduce concentration/temperature polarization effects. However, spacer geometry remains unoptimized, and studies continue to investigate a wide range of commercial and custom-made spacer designs. The in-depth discussion of the present systematic review seeks to discover the influence of Reynolds number or solution flowrate on flow hydrodynamics throughout a spacer-filled channel. A fast-flowing solution sweeping one membrane's surface first, then the neighboring membrane's surface produces good mixing action, which does not happen commonly at laminar solution flowrates. A sufficient flowrate can suppress the polarization layer, which may normally require the utilization of a simple feed channel rather than complex spacer configurations. When a recirculation eddy occurs, it disrupts the continuous flow and effectively curves the linear fluid courses. The higher the flowrate, the better the membrane performance, the higher the critical flux (or recovery rate), and the lower the inherent limitations of spacer design, spacer shadow effect, poor channel hydrodynamics, and high concentration polarization. In fact, critical flow achieves an acceptable balance between improving flow dynamics and reducing the related trade-offs, such as pressure losses and the occurrence of concentration polarization throughout the cell. If the necessary technical flowrate is not used, the real concentration potential for transport is relatively limited at low velocities than would be predicted based on bulk concentrations. Electrodialysis stack therefore may suffer from the dissociation of water molecules. Next studies should consider that applying a higher flowrate results in greater process efficiency, increased mass transfer potential at the membrane interface, and reduced stack thermal and electrical resistance, where pressure drop should always be indicated as a consequence of the spacer and circumstances used, rather than a problem.


Assuntos
Diálise , Membranas Artificiais , Purificação da Água , Hidrodinâmica , Purificação da Água/instrumentação , Purificação da Água/métodos , Salinidade , Diálise/instrumentação , Diálise/métodos , Eletroquímica/instrumentação , Eletroquímica/métodos
2.
Braz. J. Pharm. Sci. (Online) ; 59: e22430, 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1439530

RESUMO

Abstract Lipoprotein monitoring is desirable in the management of medical conditions such as atherosclerotic cardiovascular disease and coronary artery disease, in which controlling the concentration of these chylomicrons is crucial. Current clinical methods are complex and present poor reproducibility between laboratories. For these reasons, recent guidelines discard the assessment of low-density lipoprotein cholesterol (LDL-C) as a routine analysis during lipid-lowering therapies. Concerning the importance of monitoring this parameter, the authors present an electrochemical immunosensor constructed from a simple and easy-to-reproduce platform that allows detecting and quantifying LDL nanoparticles directly from human serum samples. The performance of the biosensor was studied by scanning electron microscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. The biosensing platform displays good stability and linearity between 30 mg dL-1 and 135 mg dL-1 with a detection limit of 20 mg dL-1. The proposed biosensor can be easily employed for monitoring LDL concentration in clinical treatments.


Assuntos
Transição de Fase , Lipoproteínas LDL/análise , Microscopia Eletrônica de Varredura/métodos , Eletroquímica/instrumentação , Espectroscopia Dielétrica/métodos , Hipercolesterolemia/classificação
3.
J Am Chem Soc ; 144(7): 2933-2942, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35157427

RESUMO

Light-activated photosystem II (PSII) carries out the critical step of splitting water in photosynthesis. However, PSII is susceptible to light-induced damage. Here, results are presented from a novel microbial electro-photosynthetic system (MEPS) that uses redox mediators in conjunction with an electrode to drive electron transport in live Synechocystis (ΔpsbB) cells lacking PSII. MEPS-generated, light-dependent current increased with light intensity up to 2050 µmol photons m-2 s-1, which yielded a delivery rate of 113 µmol electrons h-1 mg-chl-1 and an average current density of 150 A m-2 s-1 mg-chl-1. P700+ re-reduction kinetics demonstrated that initial rates exceeded wildtype PSII-driven electron delivery. The electron delivery occurs ahead of the cytochrome b6f complex to enable both NADPH and ATP production. This work demonstrates an electrochemical system that can drive photosynthetic electron transport, provides a platform for photosynthetic foundational studies, and has the potential for improving photosynthetic performance at high light intensities.


Assuntos
Proteínas de Bactérias/metabolismo , Hidroquinonas/metabolismo , Fotossíntese/fisiologia , Complexo de Proteína do Fotossistema I/metabolismo , Proteínas de Bactérias/genética , Complexo Citocromos b6f/metabolismo , Eletroquímica/instrumentação , Eletroquímica/métodos , Elétrons , Hidroquinonas/química , Fotossíntese/genética , Complexo de Proteína do Fotossistema II/genética , Synechocystis/metabolismo
4.
Methods Mol Biol ; 2352: 201-226, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34324189

RESUMO

The detection of neurotransmitter release from reprogrammed human cell is an important demonstration of their functionality. Electrochemistry has the distinct advantages over alternative methods that it allows for the measuring of the analyte of interest at a high temporal resolution. This is necessary for fast events, such as neurotransmitter release and reuptake, which happen in the order of milliseconds to seconds. The precise description of these kinetic events can lead to insights into the function of cells in health and disease and allows for the exploration of events that might be missed using methods that look at absolute concentration values or methods that have a slower sampling rate. In the present chapter, we describe the use of constant potential amperometry and enzyme-coated multielectrode arrays for the detection of glutamate in vitro. These biosensors have the distinct advantage of "self-referencing," a method providing high selectivity while retaining outstanding temporal resolution. Here, we provide a step-by-step user guide for a commercially available system and its application for in vitro systems such as reprogrammed cells.


Assuntos
Reprogramação Celular , Técnicas Eletroquímicas , Neurotransmissores/biossíntese , Transmissão Sináptica , Técnicas de Cultura de Células , Reprogramação Celular/genética , Análise de Dados , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletroquímica/instrumentação , Eletroquímica/métodos , Software
5.
Chem Commun (Camb) ; 57(53): 6487-6490, 2021 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-34100043

RESUMO

Herein, an electrochemical method for selectively sensing and accurately quantifying monoamine oxidase A (MAO-A) in the cortex and thalamus of a live mouse brain was reported. Using this tool, it was found that MAO-A increased Ca2+ entry into neurons via the TPRM2 channel in the live mouse brain of an AD model.


Assuntos
Encéfalo/enzimologia , Eletroquímica/instrumentação , Monoaminoxidase/metabolismo , Animais , Córtex Cerebral/enzimologia , Camundongos , Tálamo/enzimologia
6.
ACS Appl Mater Interfaces ; 13(27): 31393-31405, 2021 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-34184862

RESUMO

Reliable and accurate in situ sensors capable of detecting and quantifying troublesome marine biofilms on metallic surfaces are increasingly necessary. A 0.2 mm diameter gold electrochemical sensor was fully characterized using cyclic voltammetry in abiotic and biotic artificial seawater media within a continuous culture flow cell to detect the growth and development of an aerobic Pseudoalteromonas sp. biofilm. Deconvolution of the abiotic and biotic responses enable the constituent extracellular electron transfer and biofilm responses to be resolved. Differentiation of enhanced oxygen reduction kinetics within the aerobic bacterial biofilm is linked to enzyme and redox mediator activities.


Assuntos
Biofilmes , Eletroquímica/instrumentação , Ouro/química , Pseudoalteromonas/fisiologia , Aerobiose , Eletrodos , Transporte de Elétrons , Cinética , Pseudoalteromonas/metabolismo , Água do Mar/microbiologia , Propriedades de Superfície
7.
ACS Appl Mater Interfaces ; 13(17): 20606-20621, 2021 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-33896167

RESUMO

Disposable surgical face masks are usually used by medical/nurse staff but the current Covid-19 pandemic has caused their massive use by many people. Being worn closely attached to the people's face, they are continuously subjected to routine movements, i.e., facial expressions, breathing, and talking. These motional forces represent an unusual source of wasted mechanical energy that can be rather harvested by electromechanical transducers and exploited to power mask-integrated sensors. Typically, piezoelectric and triboelectric nanogenerators are exploited to this aim; however, most of the current devices are too thick or wide, not really conformable, and affected by humidity, which make them hardly embeddable in a mask, in contact with skin. Different from recent attempts to fabricate smart energy-harvesting cloth masks, in this work, a wearable energy harvester is rather enclosed in the mask and can be reused and not disposed. The device is a metal-free hybrid piezoelectric nanogenerator (hPENG) based on soft biocompatible materials. In particular, poly(vinylidene fluoride) (PVDF) membranes in the pure form and with a biobased plasticizer (cardanol oil, CA) are electrospun onto a laser-ablated polyimide flexible substrate attached on a skin-conformable elastomeric blend of poly(dimethylsiloxane) (PDMS) and Ecoflex. The multilayer structure of the device harnesses the piezoelectricity of the PVDF nanofibers and the friction triboelectric effects. The ultrasensitive mechanoelectrical transduction properties of the composite device are determined by the strong electrostatic behavior of the membranes and the plasticization effect of cardanol. In addition, encapsulation based on PVDF, PDMS, CA, and parylene C is used, allowing the hPENG to exhibit optimal reliability and resistance against the wet and warm atmosphere around the face mask. The proposed device reveals potential applications for the future development of smart masks with coupled energy-harvesting devices, allowing to use them not only for anti-infective protection but also to supply sensors or active antibacterial/viral devices.


Assuntos
Técnicas Biossensoriais/instrumentação , Eletroquímica/instrumentação , Máscaras , Conservação de Recursos Energéticos/métodos , Humanos
8.
Bioelectrochemistry ; 140: 107820, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33892214

RESUMO

Atomic layer deposition (ALD) is a promising method for preparing nanomaterials. The thickness and uniformity of nanomaterials can be precisely controlled. Hence, the uniform Ni nanoparticles (Ni NPs) deposited on reduced graphene oxide (rGO) by ALD and got the optimal combination interface. The morphology, structure, and electrochemical behavior of Ni NPs-rGO nanocomposite are investigated. By experiment results, the Ni NPs could occupy some active surface of rGO, resulting in high conductivity and large specific surface area of Ni NPs-rGO nanocomposite. The Ni NPs-rGO nanocomposite exhibits high electrocatalytic activity for serotonin and speeds up the electron transfer between the surface of the electrode and the solution. Therefore, the sensor is prepared by Ni NPs-rGO nanocomposite modified glassy carbon electrode (GCE) and used to sensitive detection of serotonin. By differential pulse voltammetric, the Ni NPs-rGO/GCE enhanced the current responses and showed a wide linear range of 0.02-2 µM with a low detection of 0.01 µM for serotonin (S/N = 3). The Ni NPs-rGO/GCE exhibited good stability, selectivity, and anti-interference ability that can be used for real sample detection. According to these results, the Ni NPs-rGO nanocompositeis successfully prepared by ALD. The properties of Ni NPs-rGO nanocomposite make it an attractive material for potential applications in sensors and catalysis.


Assuntos
Eletroquímica/instrumentação , Grafite/química , Níquel/química , Serotonina/análise , Nanopartículas Metálicas/química , Oxirredução
9.
ACS Appl Mater Interfaces ; 13(15): 17330-17339, 2021 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-33826286

RESUMO

On-site detection of multiple small-molecule analytes in complex sample matrixes would be highly valuable for diverse biosensing applications. Paper electrochemical devices (PEDs) offer an especially appealing sensing platform for such applications due to their low cost, portability, and ease of use. Using oligonucleotide-based aptamers as biorecognition elements, we here for the first time have developed a simple, inexpensive procedure for the fabrication of aptamer-modified multiplex PEDs (mPEDs), which can robustly and specifically detect multiple small molecules in complex samples. These devices are prepared via an ambient vacuum filtration technique using carbon and metal nanomaterials that yields precisely patterned sensing architecture featuring a silver pseudo-reference electrode, a gold counter electrode, and three gold working electrodes. The devices are user-friendly, and the fabrication procedure is highly reproducible. Each working electrode can be readily modified with different aptamers for sensitive and accurate detection of multiple small-molecule analytes in a single sample within seconds. We further demonstrate that the addition of a PDMS chamber allows us to achieve detection in microliter volumes of biological samples. We believe this approach should be highly generalizable, and given the rapid development of small-molecule aptamers, we envision that facile on-site multi-analyte detection of diverse targets in a drop of sample should be readily achievable in the near future.


Assuntos
Aptâmeros de Nucleotídeos/química , Eletroquímica/instrumentação , Papel , Dimetilpolisiloxanos/química , Nylons/química , Vácuo
10.
Bioelectrochemistry ; 140: 107823, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33915341

RESUMO

In recent years, a lot of new detection techniques for circulating tumor cells (CTCs) have been developed. Among them, electrochemical sensing technology has gradually developed because of its advantages of good selectivity, high sensitivity, low cost and rapid detection. Especially in the latest decade, the field of electrochemical biosensing has witnessed great progress, thanks to the merging of biosensing research area with nanotechnology, immunotechnology, nucleic acid technology, and microfluidic technology. In this review, the recent progress for the detection of CTCs according to the principle of detection was summarized and how they can contribute to the enhanced performance of such biosensors was explained. The latest electrode construction strategies such as rolling circle amplification reaction, DNA walker and microfluidic technology and their advantages were also introduced emphatically. Moreover, the main reasonswhy the existing biosensors have not been widely used clinically and the next research points were clearly put forward.


Assuntos
Eletroquímica/instrumentação , Biópsia Líquida/métodos , Células Neoplásicas Circulantes/patologia , Humanos
11.
Food Chem ; 352: 129327, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-33690077

RESUMO

This paper describes a voltammetric method and data analysis program developed for the detection of arsenic(III) in commercial apple juice. Arsenic(III) was detected using square wave stripping voltammetry with gold nanoparticle modified screen printed electrodes. The only sample pretreatment performed was the addition of a 100 mM phosphate buffer with a pH of 7. To compensate for interference from high ascorbic acid concentrations, a data analysis program was developed in MATLAB to fit a non-linear baseline, allowing for accurate peak height measurement. With this data analysis program, the developed methodology had a sensitivity of 0.1007 µA (µg L-1)-1 and a limit of detection of 16.73 µg L-1. A comparison between the voltammetric method and graphite furnace atomic absorption spectroscopy showed no bias in the voltammetric results and a good correlation between the two sets of predicted concentrations, with an R2 of 0.939.


Assuntos
Arsênio/análise , Carbono/química , Eletroquímica/instrumentação , Sucos de Frutas e Vegetais/análise , Ouro/química , Malus/química , Nanopartículas Metálicas/química , Eletrodos , Análise de Alimentos/instrumentação , Impressão , Fatores de Tempo
12.
Food Chem ; 352: 129430, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-33691211

RESUMO

The present work reports the development of a novel electrochemical sensor for the selective detection of fructose. The sensor was developed through electropolymerization of a molecularly imprinted polymer film on a reduced graphene oxide modified electrode. The modified electrode was characterized by cyclic voltammetry, electrochemical impedance spectroscopy, scanning electron microscopy, atomic force microscopy and RAMAN spectroscopy. Through the application of the modified electrode, the recognition of fructose molecules occurred in a concentration range of 1.0 × 10-14 to 1.0 × 10-11 mol L-1, under a Langmuir adsorption isothermal model. The sensitivity and limits of detection and quantification obtained for the sensor were 9.9 × 107 A L mol-1, 3.2 × 10-15 mol L-1 and 1.1 × 10-14 mol L-1, respectively. The analytical method used for the detection of fructose presented good reproducibility, stability and accuracy, and was successfully applied for the quantification of this sugar in orange, apple and grape juices.


Assuntos
Eletroquímica/instrumentação , Análise de Alimentos/instrumentação , Frutose/análise , Sucos de Frutas e Vegetais/análise , Grafite/química , Polímeros Molecularmente Impressos/química , Eletrodos , Frutose/química , Limite de Detecção , Polímeros Molecularmente Impressos/síntese química , Reprodutibilidade dos Testes
13.
Food Chem ; 352: 129368, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-33667921

RESUMO

A high-performance voltammetric methodology was developed to achieve ultra-sensitive detection of riboflavin, employing an electrode modified by graphene oxide-covered hollow MnO2 spheres nanocomposite with high catalytic activity, large surface area, and hierarchical layered structure. Under the optimal conditions, the current responses of the oxidation peak located at -0.39 V showed a good linear relationship versus the concentration of riboflavin in the range of 1.0 nM-4.0 µM in acetate buffer (pH 5.4). The limit of detection was determined as 0.26 nM. Moreover, the proposed electrode exhibited high reproducibility (relative standard deviation of 1.7%, n = 10) and excellent stability (97.6% sensitivity within two months), which has been successfully applied to the quantification of riboflavin in complicated food matrices, with results in good accordance with those obtained by chromatography as a reference method, indicating it is an effective sensing platform for ultra-sensitive determination of riboflavin in practical applications.


Assuntos
Eletroquímica/instrumentação , Grafite/química , Compostos de Manganês/química , Óxidos/química , Riboflavina/análise , Catálise , Eletrodos , Análise de Alimentos , Limite de Detecção , Oxirredução , Reprodutibilidade dos Testes
14.
J Mater Chem B ; 9(8): 2107-2117, 2021 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-33596277

RESUMO

Recreational use of marijuana/cannabis was legalized in Canada in 2018 and has been decriminalized in several other countries; however, the detection of impairment has remained elusive for law enforcement. The psychoactive ingredient in cannabis, delta-9-tetrahydrocannabinol (Δ9-THC), can be detected in saliva and be correlated well with the intake of cannabis. Organic electrochemical transistors (OECTs) have been used for a variety of biosensing applications like glucose, pH, ions, etc. In this work, we demonstrate the use of unfunctionalized OECTs for the detection of Δ9-THC down to 0.1 nM and 1 nM diluted in DI water and synthetic saliva buffer, respectively. These OECTs have been aerosol jet printed entirely with PEDOT:PSS as the channel material. Using a platinum gate coupled with an aerosol jet printed OECT, Δ9-THC concentration can be detected due to its oxidation reaction at the gate. These results were consistent with cyclic voltammetry measurements of Δ9-THC using Pt as the working and counter electrode. Utilizing these OECT based sensors, we have achieved high sensitivity of detection of Δ9-THC in the range from 0.1 nM to 5 µM. These OECT based Δ9-THC sensors demonstrate less than 3% error indicating good repeatability which is averaged over 15 measurements on multiple devices.


Assuntos
Dronabinol/análise , Eletroquímica/instrumentação , Impressão , Transistores Eletrônicos , Aerossóis , Materiais Biomiméticos/química , Eletrodos , Limite de Detecção , Saliva/química , Água/química
15.
Food Chem ; 349: 129202, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33582540

RESUMO

In this work, we propose a electrochemical enzyme-free glucose sensor by direct growth of conductive Ni/Co bimetal MOF on carbon cloth [Ni/Co(HHTP)MOF/CC] via a facile hydrothermal method. Due to excellent conductivity between Ni/Co(HHTP)MOF and CC, synergic catalytic effect of Ni and Co elements, the Ni/Co(HHTP)MOF/CC not only provides larger surface area and more effective active sites, but also boosts the charge transports and electro-catalytic performance. Under optimized conditions, the Ni/Co(HHTP)MOF/CC shows excellent activity with a linear range of 0.3 µM-2.312 mM, a low detection limit of 100 nM (S/N = 3), a fast response time of 2 s and a high sensitivity of 3250 µA mM-1 cm-2. Furthermore, the Ni/Co(HHTP)MOF/CC was successfully applied for the detection of glucose in real serum and beverages with competitive performances. This facile and cost-effective method provides a novel strategy for monitoring of glucose in biological and food samples.


Assuntos
Bebidas/análise , Carbono/química , Cobalto/química , Eletroquímica/instrumentação , Glucose/análise , Estruturas Metalorgânicas/química , Níquel/química , Glicemia/análise , Catálise , Condutividade Elétrica , Humanos , Limite de Detecção
16.
J Chromatogr A ; 1638: 461898, 2021 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-33486221

RESUMO

A 4-layer sandwiched device (4LSD) well suited for coupling to online ion chromatography (IC) systems was described and simultaneously performed target anion enrichment, matrix removal and sample injection within seconds. The basic assembly consisted of an extraction solution channel, a sample solution channel and two electrolyte channels. Cation-exchange resin (CER) was utilized to support the solution chamber, increase electrical conductivity and improve pressure resistance to achieve compatibility with a peristaltic pump. Filter placement ensured loop circulation of the 4LSD and prevented resin leakage. The 4LSD showed comparable performance to that of conventional solid-phase extraction (SPE) pretreatment in terms of matrix interference removal while enabling automation. The applied current, sample/extraction solution flow rate ratio, and initial concentration were discussed and optimized. Controllable 1-40-fold enrichment can be ensured. The migration phenomenon of different anions was discussed. F-, Cl-, NO2-, Br-, NO3-, SO42- and ClO4- exhibited satisfactory linear detection ranges within 2.5-1000 µg·L-1, and the calculated limits of detection (LODs) in milk formula were within the 0.097-0.79 mg·kg-1 range. The 4LSD was successfully applied to the determination of anions in milk formula with good spiked recoveries ranging between 92.54% and 107.2%, except for the NO2- recovery. The relative standard deviations (RSDs) ranged from 0.69% to 8.29%.


Assuntos
Cromatografia/métodos , Condutividade Elétrica , Eletroquímica/instrumentação , Eletroquímica/métodos , Animais , Ânions/análise , Automação , Resinas de Troca de Cátion , Limite de Detecção , Leite/química , Reprodutibilidade dos Testes , Extração em Fase Sólida
17.
Ultrason Sonochem ; 72: 105445, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33418401

RESUMO

Ultrasonic-enhanced surface-active bismuth trisulfide based core-shell nanomaterials were developed and used as an efficient modified electrode material to construct a highly sensitive antibiotic sensor. The core-shell Bi2S3@GCN electrode material was directly synthesized by in-situ growth of GCN on Bi2S3 to form core-shell like nanostar (Ti-horn, 30 kHz, and 70 W/cm2). The electrocatalyst of Bi2S3@GCN nanocomposites was efficaciously broadened towards electrochemical applications. As synthesized Bi2S3@GCN promoted the catalytic ability and electrons of GCN to transfer to Bi2S3. The single-crystalline GCN layers were uniformly grown on the surface of the Bi2S3 nanostars. Under the optimal conditions of electrochemical analysis, the CPL sensor exhibited responses directly proportional to concentrations (toxic chemical) over a range of 0.02-374.4 µM, with a nanomolar detection limit of 1.2 nM (signal-to-noise ratio S/N = 3). In addition, the modified sensor has exhibited outstanding selectivity under high concentrations of interfering chemicals and biomolecules. The satisfactory CPL recoveries in milk product illustrated the credible real-time application of the proposed Bi2S3@GCN sensors for real samples, indicating promising potential in food safety department and control. Additionally, the proposed electrochemical antibiotic sensor exhibited outstanding performance of anti-interfering ability, high stability and reproducibility.


Assuntos
Antibacterianos/análise , Bismuto/química , Eletroquímica/instrumentação , Análise de Alimentos/instrumentação , Contaminação de Alimentos/análise , Grafite/química , Compostos de Nitrogênio/química , Sulfetos/química , Ondas Ultrassônicas , Catálise , Custos e Análise de Custo , Resíduos de Drogas/análise , Eletroquímica/economia , Eletrodos , Análise de Alimentos/economia , Limite de Detecção
18.
ChemSusChem ; 14(4): 1155-1165, 2021 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-33387375

RESUMO

Bed electrodes provide high electrode area-to-volume ratios represent a promising configuration for transferring bioelectrochemical systems close to industrial applications. Nevertheless, the intrinsic electrical resistance leads to poor polarization behavior. Therefore, the distribution of Geobacter spp. and their electrochemical performance within exemplary fixed-bed electrodes are investigated. A minimally invasive sampling system allows characterization of granules from different spatial locations of bed electrodes. Cyclic voltammetry of single granules (n=63) demonstrates that the major share of electroactivity (134.3 mA L-1 ) is achieved by approximately 10 % of the bed volume, specifically that being close to the current collector. Nevertheless, analysis of the microbial community reveals that Geobacter spp. dominated all sampled granules. These findings clearly demonstrate the need for engineered bed electrodes to improve electron exchange between microorganisms and granules.


Assuntos
Reatores Biológicos/microbiologia , Eletroquímica/instrumentação , Eletrodos , Geobacter/metabolismo , Oxirredução
19.
Bioelectrochemistry ; 138: 107722, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33340819

RESUMO

The importance of RAC tracking in human biofluids has boosted many demands for designing an ultrasensitive tool to determine the trace value of the RAC from clinical, judicial, and forensic centers. In this study, an electrochemical biodevice has developed for the highly selective detection of this illegal feed additive under a double recognition strategy of the aptamer (Apt) and molecular imprinting polymer (MIP) on a glassy carbon electrode (GCE). The sensing relies on this fact that both the MIP and Apt act synergistically to trap the RAC molecules. The sensing surface fabrication steps have been monitored by some electrochemical techniques such as electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV(. The charge transfer resistance (Rct) value of the redox probe as a representative of the biodevice response has increased linearly with the RAC concentration increasing in a dynamic range of 1 fM to 1.90 µM. The detection limit (LOD) value has been estimated to be 330 aM, lower than all of the reported methods in the RAC sensing. Furthermore, the practical feasibility of biodevice has been evaluated in some human blood serum and urine samples. This strategy offers some useful advantages in reliable detection of the RAC, which may help in the routine analysis, as mandated by regulatory agencies.


Assuntos
Aptâmeros de Nucleotídeos/química , Eletroquímica/instrumentação , Polímeros Molecularmente Impressos/química , Fenetilaminas/análise , Transporte de Elétrons , Cinética , Limite de Detecção , Fenetilaminas/química
20.
Bioelectrochemistry ; 138: 107725, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33360954

RESUMO

The present work is aimed at improving the adhesion of nanomaterials at the interface of solid state working electrodes. Towards this, herein, an efficient method has been proposed that requires the electrode interface to be decorated with an optimally thin layer of Nafion. This selectively permeable layer ensures the stability of the sensor interface, without hampering the transport of biomolecules and electrons. As a case study, here, electrospun Cerium oxide nanofiber (CeNF) modified Glassy carbon electrodes (GCE) have been used as the sensing interface, and stability and performance of the GCE/CeNF/Nafion interface is evaluated using analytical electrochemistry. The CeNF is synthesized via electrospinning and is characterized using X-ray diffraction spectroscopy, Thermal gravimetry, Fourier transform infrared spectroscopy, and Field emission scanning electron microscopy. Further, detection of sepsis specific biomarker TNF-α from spiked buffer samples is demonstrated, as a case study, towards evaluating the effect of Nafion on the interfacial sensitivity. The achieved LOD of GCE/CeNF and GCE/CeNF/Nafion for TNF-α detection were 2.8 fg/mL and 1.2 fg/mL, respectively. A comparative analysis between the Electrochemical impedance spectroscopic (EIS) results of the GCE/CeNF and the GCE/CeNF/Nafion interfaces confirms the improvement in stability, without affecting the sensitivity and the limiting detection.


Assuntos
Cério/química , Eletroquímica/instrumentação , Polímeros de Fluorcarboneto/química , Nanofibras/química , Fator de Necrose Tumoral alfa/análise , Carbono/química , Eletrodos , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA