Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 853
Filtrar
3.
JACC Clin Electrophysiol ; 10(6): 1150-1160, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38703167

RESUMO

BACKGROUND: Assessment of origin of ventricular tachycardias (VTs) arising from epicardial vs endocardial sites are largely challenged by the available criteria and etiology of cardiomyopathy. Current electrocardiographic (ECG) criteria based on 12-lead ECG have varying sensitivity and specificity based on site of origin and etiology of cardiomyopathy. OBJECTIVES: This study sought to test the hypothesis that epicardial VT has a slower initial rate of depolarization than endocardial VT. METHODS: We developed a method that takes advantage of the fact that electrical conduction is faster through the cardiac conduction system than the myocardium, and that the conduction system is primarily an endocardial structure. The technique calculated the rate of change in the initial VT depolarization from a signal-averaged 12-lead ECG. We hypothesized that the rate of change of depolarization in endocardial VT would be faster than epicardial. We assessed by applying this technique among 26 patients with VT in nonischemic cardiomyopathy patients. RESULTS: When comparing patients with VTs ablated using epicardial and endocardial approaches, the rate of change of depolarization was found to be significantly slower in epicardial (6.3 ± 3.1 mV/s vs 11.4 ± 3.7 mV/s; P < 0.05). Statistical significance was found when averaging all 12 ECG leads and the limb leads, but not the precordial leads. Follow up analysis by calculation of a receiver-operating characteristic curve demonstrated that this analysis provides a strong prediction if a VT is epicardial in origin (AUC range 0.72-0.88). Slower rate of change of depolarization had high sensitivity and specificity for prediction of epicardial VT. CONCLUSIONS: This study demonstrates that depolarization rate analysis is a potential technique to predict if a VT is epicardial in nature.


Assuntos
Eletrocardiografia , Endocárdio , Pericárdio , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Endocárdio/fisiopatologia , Pericárdio/fisiopatologia , Idoso , Sistema de Condução Cardíaco/fisiopatologia , Cardiomiopatias/fisiopatologia , Adulto , Ablação por Cateter , Sensibilidade e Especificidade
4.
Heart Rhythm ; 21(10): 1970-1977, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38636932

RESUMO

BACKGROUND: Endocardial electrogram (EGM) characteristics in nonischemic cardiomyopathy (NICM) have not been explored adequately for prognostication. OBJECTIVE: We aimed to study correlation of bipolar and unipolar EGM characteristics with left ventricular ejection fraction (LVEF) and ventricular tachycardia (VT) in NICM. METHODS: Electroanatomic mapping of the left ventricle was performed. EGM characteristics were correlated with LVEF. Differences between groups with and without VT and predictors of VT were studied. RESULTS: In 43 patients, unipolar EGM variables had better correlation with baseline LVEF than bipolar EGM variables: unipolar voltage (r = +0.36), peak negative unipolar voltage (r = -0.42), peak positive unipolar voltage (r = +0.38), and percentage area of unipolar low-voltage zone (LVZ; r = -0.41). Global mean unipolar voltage (hazard ratio [HR], 0.4; 95% confidence interval [CI], 0.2-0.8), extent of unipolar LVZ (HR, 1.6; 95% CI, 1.1-2.3), and percentage area of unipolar LVZ (HR, 1.6; 95% CI, 1.1-2.3) were significant predictors of VT. For classification of patients with VT, extent of unipolar LVZ had an area under the curve of 0.82 (95% CI, 0.69-0.95; P < .001), and percentage area of unipolar LVZ had an area under the curve of 0.83 (95% CI, 0.71-0.96; P = .01). Cutoff of >3 segments for extent of unipolar LVZ had the best diagnostic accuracy (sensitivity, 90%; specificity, 67%) and cutoff of 33% for percentage area of unipolar LVZ had the best diagnostic accuracy (sensitivity, 95%; specificity, 60%) for VT. CONCLUSION: In NICM, extent and percentage area of unipolar LVZs are significant predictors of VT. Cutoffs of >3 segments of unipolar LVZ and >33% area of unipolar LVZ have good diagnostic accuracies for association with VT.


Assuntos
Cardiomiopatias , Endocárdio , Ventrículos do Coração , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Masculino , Feminino , Cardiomiopatias/fisiopatologia , Cardiomiopatias/diagnóstico , Cardiomiopatias/complicações , Pessoa de Meia-Idade , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Endocárdio/fisiopatologia , Volume Sistólico/fisiologia , Idoso , Função Ventricular Esquerda/fisiologia , Mapeamento Potencial de Superfície Corporal/métodos
5.
Comput Biol Med ; 174: 108490, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38642490

RESUMO

BACKGROUND: Pulsed Field Ablation (PFA) has recently been proposed as a non-thermal energy to treat atrial fibrillation by selective ablation of ganglionated plexi (GP) embedded in epicardial fat. While some of PFA-technologies use an endocardial approach, others use epicardial access with promising pre-clinical results. However, as each technology uses a different and sometimes proprietary pulse application protocol, the comparation between endocardial vs. epicardial approach is almost impossible in experimental terms. For this reason, our study, based on a computational model, allows a direct comparison of electric field distribution and thermal-side effects of both approaches under equal conditions in terms of electrode design, pulse protocol and anatomical characteristics of the tissues involved. METHODS: 2D computational models with axial symmetry were built for endocardial and epicardial approaches. Atrial (1.5-2.5 mm) and fat (1-5 mm) thicknesses were varied to simulate a representative sample of what happens during PFA ablation for different applied voltage values (1000, 1500 and 2000 V) and number of pulses (30 and 50). RESULTS: The epicardial approach was superior for capturing greater volumes of fat when the applied voltage was increased: 231 mm3/kV with the epicardial approach vs. 182 mm3/kV with the endocardial approach. In relation to collateral damage to the myocardium, the epicardial approach considerably spares the myocardium, unlike what happens with the endocardial approach. Although the epicardial approach caused much more thermal damage in the fat, there is not a significant difference between the approaches in terms of size of thermal damage in the myocardium. CONCLUSIONS: Our results suggest that epicardial PFA ablation of GPs is more effective than an endocardial approach. The proximity and directionality of the electric field deposited using an epicardial approach are key to ensuring that higher electric field strengths and increased temperatures are obtained within the epicardial fat, thus contributing to selective ablation of the GPs with minimal myocardial damage.


Assuntos
Fibrilação Atrial , Simulação por Computador , Endocárdio , Modelos Cardiovasculares , Pericárdio , Endocárdio/fisiopatologia , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos
6.
Coron Artery Dis ; 35(6): 451-458, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38595165

RESUMO

OBJECTIVES: This study aimed to analyze the ability of subendocardial viability ratio (SEVR) to predict the degree of coronary artery stenosis and the relationship between SEVR and the incidence of short-term cardiovascular endpoint events. METHOD: The indexes of 243 patients with chest pain were collected.. Binary logistic regression analyses were performed using the dichotomous outcome of high and non-high SYNTAX scores. Receiver operating characteristic curves were employed to comparatively analyze the diagnostic efficiencies of the indices and models. A survival analysis combined with the Cox regression analysis was performed using the Kaplan-Meier method to understand the relationship between the SEVR and the incidence of cardiovascular events within 1 year in patients with coronary heart disease (CHD). RESULTS: SEVR was significantly lower ( P  < 0.05) in the high-stenosis group than control and low-stenosis groups. The diagnostic efficacy of SEVR [area under the curve (AUC) = 0.861] was better than those of age (AUC = 0.745), ABI (AUC = 0.739), and AIx@HR75 (AUC = 0.659). The cutoff SEVR was 1.105. In patients with confirmed CHD who had been discharged from the hospital for 1 year, only SEVR affected survival outcomes (hazard ratio = 0.010; 95% confidence interval: 0.001-0.418; P  = 0.016). CONCLUSION: A significant decrease in SEVR predicted severe coronary artery stenosis, with a cutoff value of 1.105 and an accuracy of 0.861. In patients with CHD, the lower the SEVR, the higher was the rate of cardiovascular events at 1 year after hospital discharge.


Assuntos
Angiografia Coronária , Estenose Coronária , Valor Preditivo dos Testes , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estenose Coronária/epidemiologia , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico , Estenose Coronária/complicações , Incidência , Angiografia Coronária/métodos , Idoso , Índice de Gravidade de Doença , Endocárdio/fisiopatologia , Curva ROC , Estudos Retrospectivos , Doença das Coronárias/epidemiologia , Doença das Coronárias/fisiopatologia , Prognóstico , Fatores de Risco
7.
J Cardiovasc Electrophysiol ; 35(5): 965-974, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38477371

RESUMO

INTRODUCTION: Repolarization dispersion in the right ventricular outflow tract (RVOT) contributes to the type-1 electrocardiographic (ECG) phenotype of Brugada syndrome (BrS), while data on the significance and feasibility of mapping repolarization dispersion in BrS patients are scarce. Moreover, the role of endocardial repolarization dispersion in BrS is poorly investigated. We aimed to assess endocardial repolarization patterns through an automated calculation of activation recovery interval (ARI) estimated on unipolar electrograms (UEGs) in spontaneous type-1 BrS patients and controls; we also investigated the relation between ARI and right ventricle activation time (RVAT), and T-wave peak-to-end interval (Tpe) in BrS patients. METHODS: Patients underwent endocardial high-density electroanatomical mapping (HDEAM); BrS showing an overt type-1 ECG were defined as OType1, while those without (latent type-1 ECG and LType1) received ajmaline infusion. BrS patients only underwent programmed ventricular stimulation (PVS). Data were elaborated to obtain ARI corrected with the Bazett formula (ARIc), while RVAT was derived from activation maps. RESULTS: 39 BrS subjects (24 OType1 and 15 LTtype1) and 4 controls were enrolled. OType1 and post-ajmaline LType1 showed longer mean ARIc than controls (306 ± 27.3 ms and 333.3 ± 16.3 ms vs. 281.7 ± 10.3 ms, p = .05 and p < .001, respectively). Ajmaline induced a significant prolongation of ARIc compared to pre-ajmaline LTtype1 (333.3 ± 16.3 vs. 303.4 ± 20.7 ms, p < .001) and OType1 (306 ± 27.3 ms, p < .001). In patients with type-1 ECG (OTtype1 and post-ajmaline LType1) ARIc correlated with RVAT (r = .34, p = .04) and Tpec (r = .60, p < .001), especially in OType1 subjects (r = .55, p = .008 and r = .65 p < .001, respectively). CONCLUSION: ARIc mapping demonstrates increased endocardial repolarization dispersion in RVOT in BrS. Endocardial ARIc positively correlates with RVAT and Tpec, especially in OType1.


Assuntos
Potenciais de Ação , Algoritmos , Síndrome de Brugada , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Endocárdio , Frequência Cardíaca , Valor Preditivo dos Testes , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Síndrome de Brugada/fisiopatologia , Síndrome de Brugada/diagnóstico , Endocárdio/fisiopatologia , Adulto , Fatores de Tempo , Estudos de Casos e Controles , Ajmalina/administração & dosagem , Automação , Função Ventricular Direita , Estimulação Cardíaca Artificial , Idoso , Processamento de Sinais Assistido por Computador
8.
Int Heart J ; 63(1): 141-146, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35095062

RESUMO

We have previously reported that atrial endocardial remodeling is induced by atrial fibrillation (AF), and the endocardial dysfunction may be partly responsible for the thrombus formation in the left atrium associated with AF. However, the relationship between the endocardial dysfunction and the epidemiologically determined risk factors of AF-related strokes, including aging, hypertension, and diabetes mellitus, is yet to be elucidated.To test the hypothesis that aging, hypertension, and diabetes mellitus individually impair the atrial endocardial function in conjunction with AF, we have analyzed the expression of the tissue factor pathway inhibitor (TFPI) and thrombomodulin (TM) in the atrial endocardium in 30-week-old Wister-Kyoto (WKY), 60-week-old WKY, 30-week-old spontaneously hypertensive rats (SHR), and 30-week Goto-Kakizaki (GK) rats during normal sinus rhythm and after rapid atrial pacing at 1200 bpm for 8 hours, using Western blotting and immunohistochemical analysis. Even during sinus rhythm, the TFPI and TM expressions were noted to be remarkably downregulated in the atrial endocardium among 60-week-old WKY rats. In contrast, in SHR rats, only the TFPI expression has significantly decreased, while TM was preserved to the same level of control 30-week-old WKY rats. Rapid atrial pacing significantly reduced the TM and TFPI expression similarly in each model, thereby augmenting the endocardial dysfunction during normal sinus rhythm individually induced by the risk factors themselves prior to AF.Aging and hypertension, both of which are epidemiologically well-known risk factors for strokes in AF, have been associated with a specific atrial endocardial impairment prior to AF that could additionally disturb the antithrombotic function of the atrial endocardium.


Assuntos
Envelhecimento/fisiologia , Fibrilação Atrial/metabolismo , Endocárdio/metabolismo , Hipertensão/complicações , Lipoproteínas/metabolismo , Trombomodulina/metabolismo , Animais , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial , Modelos Animais de Doenças , Endocárdio/fisiopatologia , Átrios do Coração/metabolismo , Átrios do Coração/fisiopatologia , Hipertensão/metabolismo , Hipertensão/fisiopatologia , Masculino , Ratos , Ratos Endogâmicos SHR , Ratos Endogâmicos WKY
10.
Pacing Clin Electrophysiol ; 44(3): 462-471, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33433929

RESUMO

BACKGROUND: Epicardial to endocardial breakthrough (EEB) exists widely in atrial arrhythmia and is a cause for intractable cavotricuspid isthmus (CTI)-dependent atrial flutter (AFL). This study aimed to investigate the electrophysiological features of EEB in EEB-related CTI dependent AFL. METHODS: Six patients with EEB-related CTI-dependent AFL were identified among 142 consecutive patients who underwent CTI-dependent AFL catheter ablation with an ultra-high-density, high-resolution mapping system in three institutions. Activation maps and ablation procedure were analyzed. RESULTS: A total of seven EEBs were found in six patients. Four EEBs (including three at the right atrial septum and one in paraseptal isthmus) were recorded in three patients during tachycardia. The other three EEBs were identified at the inferolateral right atrium (RA) during pacing from the coronary sinus. The conduction characteristics through the EEB-mediated structures were evaluated in three patients. Two patients only showed unidirectional conduction. Activation maps indicated that CTI-dependent AFL with EEB at the atrial septum was actually bi-atrial macro-reentrant atrial tachycardia (BiAT). Intensive ablation at the central isthmus could block CTI bidirectionally in four cases. However, ablation targeted at the inferolateral RA EEB was required in two cases. Meanwhile, local potentials at the EEB location gradually split into two components with a change in activation sequence. CONCLUSIONS: EEB is an underlying cause for intractable CTI-dependent AFL. EEB-mediated structure might show unidirectional conduction. CTI-dependent AFL with EEB at the atrial septum may represent BiAT. Intensive ablation targeting the central isthmus or EEB at the inferolateral RA could block the CTI bidirectionally.


Assuntos
Flutter Atrial/fisiopatologia , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Endocárdio/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Adulto , Idoso , Técnicas Eletrofisiológicas Cardíacas , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia
11.
Development ; 148(2)2021 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-33234717

RESUMO

The ability of zebrafish to heal their heart after injury makes them an attractive model for investigating the mechanisms governing the regenerative process. In this study, we show that the gene cellular communication network factor 2a (ccn2a), previously known as ctgfa, is induced in endocardial cells in the injured tissue and regulates CM proliferation and repopulation of the damaged tissue. We find that, whereas in wild-type animals, CMs track along the newly formed blood vessels that revascularize the injured tissue, in ccn2a mutants CM proliferation and repopulation are disrupted, despite apparently unaffected revascularization. In addition, we find that ccn2a overexpression enhances CM proliferation and improves the resolution of transient collagen deposition. Through loss- and gain-of-function as well as pharmacological approaches, we provide evidence that Ccn2a is necessary for and promotes heart regeneration by enhancing the expression of pro-regenerative extracellular matrix genes, and by inhibiting the chemokine receptor gene cxcr3.1 through a mechanism involving Tgfß/pSmad3 signaling. Thus, Ccn2a positively modulates the innate regenerative response of the adult zebrafish heart.


Assuntos
Fator de Crescimento do Tecido Conjuntivo/metabolismo , Coração/fisiopatologia , Regeneração , Proteínas de Peixe-Zebra/metabolismo , Peixe-Zebra/fisiologia , Animais , Núcleo Celular/metabolismo , Proliferação de Células , Fator de Crescimento do Tecido Conjuntivo/genética , Vasos Coronários/metabolismo , Endocárdio/patologia , Endocárdio/fisiopatologia , Matriz Extracelular/genética , Regulação da Expressão Gênica no Desenvolvimento , Mutação/genética , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/patologia , Fosforilação , Transporte Proteico , Proteínas Smad/metabolismo , Fator de Crescimento Transformador beta1/metabolismo , Proteínas de Peixe-Zebra/genética
13.
J Am Heart Assoc ; 9(17): e017069, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32808551

RESUMO

Background The significance of endo-epicardial asynchrony (EEA) and atrial conduction block (CB), which play an important role in the pathophysiology of atrial fibrillation (AF) during sinus rhythm is poorly understood. The aim of our study was therefore to examine 3-dimensional activation of the human right atrium (RA). Methods and Results Eighty patients (79% men, 39% history of AF) underwent simultaneous endo-epicardial sinus rhythm mapping of the inferior, middle and superior RA. Areas of CB were defined as conduction delays of ≥12 ms, EEA as activation time differences of opposite electrodes of ≥15 ms and transmural CB as CB at similar endo-epicardial sites. CB was more pronounced at the endocardium (all locations P<0.025). Amount, extensiveness and severity of CB was higher at the superior RA. Transmural CB at the inferior RA was associated with a higher incidence of post-operative AF (P=0.03). EEA occurred up to 84 ms and was more pronounced at the superior RA (superior: 27 ms [interquartile range, 18.3-39.3], versus mid-RA: 20.3 ms [interquartile range, 0-29.9], and inferior RA: 0 ms [interquartile range, 0-21], P<0.001). Hypertension (P=0.009), diabetes mellitus (P=0.018), and hypercholesterolemia (P=0.015) were associated with a higher degree of EEA. CB (P=0.007) and EEA (P=0.037) were more pronounced in patients with a history of persistent AF compared with patients without AF history. Conclusions This study provides important insights into complex atrial endo-epicardial excitation. Significant differences in conduction disorders between the endo- and epicardium and a significant degree of EEA are already present during sinus rhythm and are more pronounced in patients with cardiovascular risk factors or a history of persistent AF.


Assuntos
Fibrilação Atrial/fisiopatologia , Mapeamento Epicárdico/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Doença do Sistema de Condução Cardíaco/fisiopatologia , Complicações do Diabetes/fisiopatologia , Eletrofisiologia/métodos , Endocárdio/fisiopatologia , Feminino , Bloqueio Cardíaco/fisiopatologia , Fatores de Risco de Doenças Cardíacas , Humanos , Hipercolesterolemia/complicações , Hipercolesterolemia/fisiopatologia , Hipertensão/complicações , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Pericárdio/fisiopatologia , Índice de Gravidade de Doença
14.
Circ Arrhythm Electrophysiol ; 13(8): e008512, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32634027

RESUMO

BACKGROUND: Endocardial-epicardial dissociation and focal breakthroughs in humans with atrial fibrillation (AF) have been recently demonstrated using activation mapping of short 10-second AF segments. In the current study, we used simultaneous endo-epi phase mapping to characterize endo-epi activation patterns on long segments of human persistent AF. METHODS: Simultaneous intraoperative mapping of endo- and epicardial lateral right atrium wall was performed in patients with persistent AF using 2 high-density grid catheters (16 electrodes, 3 mm spacing). Filtered unipolar and bipolar electrograms of continuous 2-minute AF recordings and electrodes locations were exported for phase analyses. We defined endocardial-epicardial dissociation as phase difference of ≥20 ms between paired endo-epi electrodes. Wavefronts were classified as rotations, single wavefronts, focal waves, or disorganized activity as per standard criteria. Endo-Epi wavefront patterns were simultaneously compared on dynamic phase maps. Complex fractionated electrograms were defined as bipolar electrograms with ≥5 directional changes occupying at least 70% of sample duration. RESULTS: Fourteen patients with persistent AF undergoing cardiac surgery were included. Endocardial-epicardial dissociation was seen in 50.3% of phase maps with significant temporal heterogeneity. Disorganized activity (Endo: 41.3% versus Epi: 46.8%, P=0.0194) and single wavefronts (Endo: 31.3% versus Epi: 28.1%, P=0.129) were the dominant patterns. Transient rotations (Endo: 22% versus Epi: 19.2%, P=0.169; mean duration: 590±140 ms) and nonsustained focal waves (Endo: 1.2% versus Epi: 1.6%, P=0.669) were also observed. Apparent transmural migration of rotational activations (n=6) from the epi- to the endocardium was seen in 2 patients. Electrogram fractionation was significantly higher in the epicardium than endocardium (61.2% versus 51.6%, P<0.0001). CONCLUSIONS: Simultaneous endo-epi phase mapping of prolonged human persistent AF recordings shows significant Endocardial-epicardial dissociation marked temporal heterogeneity, discordant and transitioning wavefronts patterns and complex fractionations. No sustained focal activity was observed. Such complex 3-dimensional interactions provide insight into why endocardial mapping alone may not fully characterize the AF mechanism and why endocardial ablation may not be sufficient. Graphic Abstract: A graphic abstract is available for this article.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Cateterismo Cardíaco , Endocárdio/fisiopatologia , Mapeamento Epicárdico , Frequência Cardíaca , Pericárdio/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Mapeamento Epicárdico/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Tempo
15.
Pacing Clin Electrophysiol ; 43(9): 966-973, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32330307

RESUMO

BACKGROUND: Endocardial pacing may be beneficial in patients who fail to improve following conventional epicardial cardiac resynchronization therapy (CRT). The potential to pace anywhere inside the left ventricle thus avoiding myocardial scar and targeting the latest activating segments may be particularly important. The WiSE-CRT system (EBR systems, Sunnyvale, CA) reliably produces wireless, endocardial left ventricular (LV) pacing. The purpose of this analysis was to determine whether this system improved symptoms or led to LV remodeling in patients who were nonresponders to conventional CRT. METHOD: An international, multicenter registry of patients who were nonresponders to conventional CRT and underwent implantation with the WiSE-CRT system was collected. RESULTS: Twenty-two patients were included; 20 patients underwent successful implantation with confirmation of endocardial biventricular pacing and in 2 patients, there was a failure of electrode capture. Eighteen patients proceeded to 6-month follow-up; endocardial pacing resulted in a significant reduction in QRS duration compared with intrinsic QRS duration (26.6 ± 24.4 ms; P = .002) and improvement in left ventricular ejection fraction (LVEF) (4.7 ± 7.9%; P = .021). The mean reduction in left ventricular end-diastolic volume was 8.3 ± 42.3 cm3 (P = .458) and left ventricular end-systolic volume (LVESV) was 13.1 ± 44.3 cm3 (P = .271), which were statistically nonsignificant. Overall, 55.6% of patients had improvement in their clinical composite score and 66.7% had a reduction in LVESV ≥15% and/or absolute improvement in LVEF ≥5%. CONCLUSION: Nonresponders to conventional CRT have few remaining treatment options. We have shown in this high-risk patient group that the WiSE-CRT system results in improvement in their clinical composite scores and leads to LV remodeling.


Assuntos
Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/efeitos adversos , Endocárdio/fisiopatologia , Marca-Passo Artificial , Idoso , Feminino , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Falha de Tratamento , Remodelação Ventricular
16.
Sci Rep ; 10(1): 2617, 2020 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-32054938

RESUMO

Cardiac pathologies associated with arrhythmic activity are often accompanied by inflammation. The contribution of inflammatory cells to the electrophysiological properties of injured myocardium is unknown. Myocardial scar cell types and intercellular contacts were analyzed using a three-dimensional reconstruction from serial blockface scanning electron microscopy data. Three distinct cell populations were identified: inflammatory, fibroblastic and endocardial cells. While individual fibroblastic cells interface with a greater number of cells, inflammatory cells have the largest contact area suggesting a role in establishing intercellular electrical connections in scar tissue. Optical mapping was used to study the electrophysiological properties of scars in fetal liver chimeric mice generated using connexin43 knockout donors (bmpKO). Voltage changes were elicited in response to applied current pulses. Isopotential maps showed a steeper pattern of decay with distance from the electrode in scars compared with uninjured regions, suggesting reduced electrical coupling. The tissue decay constant, defined as the distance voltage reaches 37% of the amplitude at the edge of the scar, was 0.48 ± 0.04 mm (n = 11) in the scar of the bmpCTL group and decreased 37.5% in the bmpKO group (n = 10). Together these data demonstrate inflammatory cells significantly contribute to scar electrophysiology through coupling mediated at least partially by connexin43 expression.


Assuntos
Células da Medula Óssea/patologia , Conexina 43/análise , Traumatismos Cardíacos/patologia , Miocárdio/patologia , Animais , Arritmias Cardíacas/patologia , Arritmias Cardíacas/fisiopatologia , Endocárdio/citologia , Endocárdio/patologia , Endocárdio/fisiopatologia , Fibroblastos/patologia , Traumatismos Cardíacos/fisiopatologia , Imageamento Tridimensional , Inflamação/patologia , Inflamação/fisiopatologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Microscopia Eletrônica de Varredura , Miocárdio/citologia
17.
Card Electrophysiol Clin ; 12(1): 47-54, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32067647

RESUMO

Left atrial appendage closure (LAAC) is a safe and effective therapy for the prevention of stroke in patients with nonvalvular atrial fibrillation and high bleeding risk with oral anticoagulants. Multimodality imaging with transesophageal echocardiography and computed tomography angiography to define the anatomy and its implications on endocardial exclusion is becoming increasingly important. The only LAAC device currently approved for clinical use in the United States is the WATCHMAN device. Systematic assessment of the transseptal crossing site, left atrial appendage anatomy, adequate device size selection, and device postdeployment evaluation is essential for the safety and efficacy of the procedure.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos/métodos , Anticoagulantes/uso terapêutico , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Apêndice Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Angiografia por Tomografia Computadorizada , Ecocardiografia Transesofagiana , Endocárdio/diagnóstico por imagem , Endocárdio/fisiopatologia , Endocárdio/cirurgia , Humanos , Acidente Vascular Cerebral/tratamento farmacológico , Acidente Vascular Cerebral/prevenção & controle
18.
Ann Thorac Cardiovasc Surg ; 26(1): 13-21, 2020 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-31495813

RESUMO

PURPOSE: The Convergent procedure is a hybrid, multidisciplinary treatment for symptomatic atrial fibrillation (AF) consisting of minimally invasive surgical epicardial ablation and percutaneous/catheter endocardial ablation. We investigated outcomes following introduction of the Convergent procedure at our institution. METHODS: Retrospective study examining single-center outcomes. Demographic, procedural, and post-procedural variables were collected with follow-up data obtained at 3, 6, and 12 months. RESULTS: In all, 36 patients with paroxysmal (11%) or persistent/long-standing persistent (89%) AF underwent the Convergent procedure. 36% also underwent concomitant left atrial appendage (LAA) exclusion by thoracoscopic placement of an epicardial clip. Mean age 60.6 ± 8.0 years with mean arrhythmia burden of 3.9 ± 2.7 years. All patients had failed prior attempts at medical management, 81% had failed prior cardioversion, and 17% had failed prior catheter ablation. Convergent was performed successfully in all patients with no peri-procedural deaths or major complications. At 3 and 12 months, 77.8% and 77.3% of patients, respectively, were free from symptomatic arrhythmia. 65.8% were off anti-arrhythmic medication at 12 months. CONCLUSIONS: The Convergent procedure is safe and has good short- and intermediate-term clinical success rates. This unique hybrid approach combines strengths of surgical and catheter ablation and should be part of any comprehensive AF treatment program.


Assuntos
Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos , Ablação por Cateter/efeitos adversos , Endocárdio/cirurgia , Pericárdio/cirurgia , Centros de Atenção Terciária , Idoso , Antiarrítmicos/uso terapêutico , Anticoagulantes/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Endocárdio/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio/fisiopatologia , Recidiva , Encaminhamento e Consulta , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
J Cardiovasc Electrophysiol ; 31(1): 112-118, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31724790

RESUMO

INTRODUCTION: Isolation of the left atrial appendage (LAA) is often performed in persistent atrial fibrillation (AF). Propagation patterns in the LAA during AF remain to be elucidated. We sought to characterize propagation patterns in the LAA during AF in persistent AF. METHODS: Persistent AF patients undergoing catheter ablation were studied. Pulmonary vein isolation (PVI) was performed during continuous AF. If AF was not terminated by PVI, bi-atrial mapping was performed using a multi-electrode catheter during AF. Maps were collected at each site for 30 seconds and analyzed offline with a novel software, CARTOFINDER. This software made automatic determinations of whether activation was focal or rotational. The left atrium (LA) was divided into five regions, of which the LAA was one, and the right atrium (RA) into three. RESULTS: Eighty patients were studied (62 ± 10 years, 65 males). On average, 9.6 ± 2.2 and 4.1 ± 1.2 maps were created in the LA and RA, respectively. The LAA was mapped in 70 patients, resulting in 85 maps. In the LAA, activation was identified as focal more often than rotational (64 [91%] vs 10 [14%] patients, P < .001), seven patients displayed both. The number of focal activation events was greatest in the LAA (28.5 events/30 seconds [interquartile range, 15-54]) of the eight atrial regions. During focal activation, sites designated as earliest activation frequently covered a wide area, rather than being localized to a discrete site (5.4 ± 3.1 electrodes). CONCLUSIONS: The results of this study suggest that focal activation is a major mechanism underlying the arrhythmogenicity of the LAA in persistent AF.


Assuntos
Potenciais de Ação , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo , Técnicas Eletrofisiológicas Cardíacas , Endocárdio/fisiopatologia , Frequência Cardíaca , Veias Pulmonares/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/cirurgia , Fatores de Tempo
20.
Ultrasound Med Biol ; 46(2): 405-414, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31767455

RESUMO

Differentiation between epicardial and endocardial ventricular activation remains a challenge despite the latest technologies available. The aim of the present study was to develop a new tool method, based on electromechanical wave imaging (EWI), to improve arrhythmogenic substrate activation analysis. Experiments were conducted on left ventricles (LVs) of four isolated working mode swine hearts. The protocol aimed at demonstrating that different patterns of mechanical activation could be observed whether the ventricle was in sinus rhythm, paced from the epicardium or from the endocardium. A total of 72 EWI acquisitions were recorded on the anterior, lateral and posterior segments of the LV. A total of 54 loop records were blindly assigned to two readers. EWI sequences interpretations were correct in 89% of cases. The overall agreement rate between the two readers was 83%. When in a paced ventricle, the origin of the wave front was focal and originated from the endocardium or the epicardium. In sinus rhythm, wave front was global and activated within the entire endocardium toward the epicardium at a speed of 1.7 ± 0.28 m·s-1. Wave front speeds were respectively measured when the endocardium or the epicardium were paced at a speed of 1.1 ± 0.35 m·s-1 versus 1.3 ± 0.34 m·s-1 (p = NS). EWI activation mapping allows activation localization within the LV wall and calculation of the wave front propagation speed through the muscle. In the future, this technology could help localize activation within the LV thickness during complex ablation procedures.


Assuntos
Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Endocárdio/diagnóstico por imagem , Endocárdio/fisiopatologia , Coração/diagnóstico por imagem , Coração/fisiopatologia , Pericárdio/diagnóstico por imagem , Pericárdio/fisiopatologia , Animais , Técnicas Eletrofisiológicas Cardíacas , Suínos , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA