Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.194
Filtrar
2.
Crit Care ; 28(1): 171, 2024 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773629

RESUMO

BACKGROUND: Tidal expiratory flow limitation (EFLT) complicates the delivery of mechanical ventilation but is only diagnosed by performing specific manoeuvres. Instantaneous analysis of expiratory resistance (Rex) can be an alternative way to detect EFLT without changing ventilatory settings. This study aimed to determine the agreement of EFLT detection by Rex analysis and the PEEP reduction manoeuvre using contingency table and agreement coefficient. The patterns of Rex were explored. METHODS: Medical patients ≥ 15-year-old receiving mechanical ventilation underwent a PEEP reduction manoeuvre from 5 cmH2O to zero for EFLT detection. Waveforms were recorded and analyzed off-line. The instantaneous Rex was calculated and was plotted against the volume axis, overlapped by the flow-volume loop for inspection. Lung mechanics, characteristics of the patients, and clinical outcomes were collected. The result of the Rex method was validated using a separate independent dataset. RESULTS: 339 patients initially enrolled and underwent a PEEP reduction. The prevalence of EFLT was 16.5%. EFLT patients had higher adjusted hospital mortality than non-EFLT cases. The Rex method showed 20% prevalence of EFLT and the result was 90.3% in agreement with PEEP reduction manoeuvre. In the validation dataset, the Rex method had resulted in 91.4% agreement. Three patterns of Rex were identified: no EFLT, early EFLT, associated with airway disease, and late EFLT, associated with non-airway diseases, including obesity. In early EFLT, external PEEP was less likely to eliminate EFLT. CONCLUSIONS: The Rex method shows an excellent agreement with the PEEP reduction manoeuvre and allows real-time detection of EFLT. Two subtypes of EFLT are identified by Rex analysis. TRIAL REGISTRATION: Clinical trial registered with www.thaiclinicaltrials.org (TCTR20190318003). The registration date was on 18 March 2019, and the first subject enrollment was performed on 26 March 2019.


Assuntos
Respiração Artificial , Humanos , Masculino , Feminino , Respiração Artificial/métodos , Respiração Artificial/estatística & dados numéricos , Pessoa de Meia-Idade , Idoso , Volume de Ventilação Pulmonar/fisiologia , Respiração com Pressão Positiva/métodos , Respiração com Pressão Positiva/estatística & dados numéricos , Respiração com Pressão Positiva/normas , Expiração/fisiologia , Adulto
3.
Spectrochim Acta A Mol Biomol Spectrosc ; 318: 124473, 2024 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-38795528

RESUMO

Infrared spectroscopy appears to be a promising analytical method for the metabolic analysis of breath. However, due to the presence of trace amounts in exhaled breath, the absorption strength of the metabolites remains extremely low. In such low detection limits, the nonlinear detection sensitivity of the infrared detector and electronic noise strongly modify the baseline of the acquired infrared spectra of breath. Fitting the reference molecular spectra with the baseline-modified spectral features of breath metabolites does not provide accurate identification. Therefore, baseline correction of the acquired infrared spectra of breath is the primary requirement for the success of breath-based infrared diagnosis. A selective spectral region-based, simple baseline correction method is proposed for the infrared spectroscopy of breath.


Assuntos
Testes Respiratórios , Expiração , Espectrofotometria Infravermelho , Testes Respiratórios/métodos , Humanos , Espectrofotometria Infravermelho/métodos , Expiração/fisiologia , Masculino , Adulto , Feminino
4.
J Appl Physiol (1985) ; 136(6): 1591-1603, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38695354

RESUMO

We investigated the effect of exercise intensity and tolerable duration on the development of exercise-induced diaphragm and expiratory muscle fatigue. Ten healthy adults (25 ± 5 yr; 2 females) cycled to intolerance on three separate occasions: 1) 5% below critical power ( 0.05). In conclusion, the magnitude of exercise-induced diaphragm fatigue was greater after longer-duration severe exercise than after shorter-duration severe and heavy exercise. By contrast, the magnitude of exercise-induced expiratory muscle fatigue was unaffected by exercise intensity and tolerable duration.NEW & NOTEWORTHY Exercise-induced respiratory muscle fatigue contributes to limiting exercise tolerance. Accordingly, better understanding the exercise conditions under which respiratory muscle fatigue occurs is warranted. Although heavy-intensity as well as short- and long-duration severe-intensity exercise performed to intolerance elicit diaphragm and expiratory muscle fatigue, we find, for the first time, that the relationship between exercise intensity, exercise duration, and the magnitude of exercise-induced fatigue is different for the diaphragm compared with the expiratory muscles.


Assuntos
Diafragma , Exercício Físico , Fadiga Muscular , Humanos , Fadiga Muscular/fisiologia , Masculino , Feminino , Diafragma/fisiologia , Diafragma/fisiopatologia , Adulto , Exercício Físico/fisiologia , Adulto Jovem , Consumo de Oxigênio/fisiologia , Músculos Respiratórios/fisiologia , Expiração/fisiologia
7.
Science ; 384(6693): 295-301, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38669574

RESUMO

Airway neuroendocrine (NE) cells have been proposed to serve as specialized sensory epithelial cells that modulate respiratory behavior by communicating with nearby nerve endings. However, their functional properties and physiological roles in the healthy lung, trachea, and larynx remain largely unknown. In this work, we show that murine NE cells in these compartments have distinct biophysical properties but share sensitivity to two commonly aspirated noxious stimuli, water and acid. Moreover, we found that tracheal and laryngeal NE cells protect the airways by releasing adenosine 5'-triphosphate (ATP) to activate purinoreceptive sensory neurons that initiate swallowing and expiratory reflexes. Our work uncovers the broad molecular and biophysical diversity of NE cells across the airways and reveals mechanisms by which these specialized excitable cells serve as sentinels for activating protective responses.


Assuntos
Trifosfato de Adenosina , Laringe , Células Neuroendócrinas , Reflexo , Traqueia , Animais , Camundongos , Células Neuroendócrinas/metabolismo , Laringe/fisiologia , Trifosfato de Adenosina/metabolismo , Reflexo/fisiologia , Traqueia/inervação , Traqueia/citologia , Deglutição , Pulmão/fisiologia , Expiração/fisiologia , Água/metabolismo , Células Receptoras Sensoriais/fisiologia , Camundongos Endogâmicos C57BL
8.
PLoS One ; 19(4): e0301971, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38648227

RESUMO

This work, in a pioneering approach, attempts to build a biometric system that works purely based on the fluid mechanics governing exhaled breath. We test the hypothesis that the structure of turbulence in exhaled human breath can be exploited to build biometric algorithms. This work relies on the idea that the extrathoracic airway is unique for every individual, making the exhaled breath a biomarker. Methods including classical multi-dimensional hypothesis testing approach and machine learning models are employed in building user authentication algorithms, namely user confirmation and user identification. A user confirmation algorithm tries to verify whether a user is the person they claim to be. A user identification algorithm tries to identify a user's identity with no prior information available. A dataset of exhaled breath time series samples from 94 human subjects was used to evaluate the performance of these algorithms. The user confirmation algorithms performed exceedingly well for the given dataset with over 97% true confirmation rate. The machine learning based algorithm achieved a good true confirmation rate, reiterating our understanding of why machine learning based algorithms typically outperform classical hypothesis test based algorithms. The user identification algorithm performs reasonably well with the provided dataset with over 50% of the users identified as being within two possible suspects. We show surprisingly unique turbulent signatures in the exhaled breath that have not been discovered before. In addition to discussions on a novel biometric system, we make arguments to utilise this idea as a tool to gain insights into the morphometric variation of extrathoracic airway across individuals. Such tools are expected to have future potential in the area of personalised medicines.


Assuntos
Algoritmos , Testes Respiratórios , Expiração , Aprendizado de Máquina , Humanos , Expiração/fisiologia , Testes Respiratórios/métodos , Identificação Biométrica/métodos
12.
Clin Physiol Funct Imaging ; 44(4): 313-323, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38497355

RESUMO

OBJECTIVES: This study aimed to assess the acute impact of distinct loading breathing types and intensities on cardiac autonomic function and hemodynamic responses in healthy young adults. METHODS: A randomized, crossover trial involved 28 participants who underwent inspiratory resistive breathing, expiratory resistive breathing (ERB) and combined resistive breathing, each at 30% and 60% of maximal respiratory pressures. Data on heart rate variability (HRV) and hemodynamic parameters were collected during each trial. RESULTS: The study revealed significant main and interaction effects for both the performed task and the intensity across all measured variables (all p < 0.001). ERB at 60% load demonstrated significantly higher HRV values in the standard deviation of normal-to-normal RR intervals, the square root of the mean squared difference of successive normal-to-normal RR intervals and high-frequency power, as well as significantly lower values in heart rate, stroke volume, stroke volume index, cardiac output, cardiac index, end-diastolic volume and end-diastolic volume index, compared to other loaded protocols (all p < 0.001). CONCLUSION: These findings highlight the acute effect of type-specific and load-dependent resistive breathing on cardiac autonomic and hemodynamic functions, where ERB at 60% intensity showed the most significant cardiovagal modulation while causing the least hemodynamic alterations.


Assuntos
Sistema Nervoso Autônomo , Estudos Cross-Over , Frequência Cardíaca , Coração , Hemodinâmica , Humanos , Frequência Cardíaca/fisiologia , Masculino , Sistema Nervoso Autônomo/fisiologia , Feminino , Adulto Jovem , Hemodinâmica/fisiologia , Coração/fisiologia , Coração/inervação , Adulto , Fatores de Tempo , Inalação , Resistência das Vias Respiratórias , Voluntários Saudáveis , Exercícios Respiratórios/métodos , Expiração/fisiologia , Pulmão/fisiologia , Débito Cardíaco/fisiologia
13.
Br J Radiol ; 97(1157): 980-992, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38547402

RESUMO

OBJECTIVES: To develop a mapping model between skin surface motion and internal tumour motion and deformation using end-of-exhalation (EOE) and end-of-inhalation (EOI) 3D CT images for tracking lung tumours during respiration. METHODS: Before treatment, skin and tumour surfaces were segmented and reconstructed from the EOE and the EOI 3D CT images. A non-rigid registration algorithm was used to register the EOE skin and tumour surfaces to the EOI, resulting in a displacement vector field that was then used to construct a mapping model. During treatment, the EOE skin surface was registered to the real-time, yielding a real-time skin surface displacement vector field. Using the mapping model generated, the input of a real-time skin surface can be used to calculate the real-time tumour surface. The proposed method was validated with and without simulated noise on 4D CT images from 15 patients at Léon Bérard Cancer Center and the 4D-lung dataset. RESULTS: The average centre position error, dice similarity coefficient (DSC), 95%-Hausdorff distance and mean distance to agreement of the tumour surfaces were 1.29 mm, 0.924, 2.76 mm, and 1.13 mm without simulated noise, respectively. With simulated noise, these values were 1.33 mm, 0.920, 2.79 mm, and 1.15 mm, respectively. CONCLUSIONS: A patient-specific model was proposed and validated that was constructed using only EOE and EOI 3D CT images and real-time skin surface images to predict internal tumour motion and deformation during respiratory motion. ADVANCES IN KNOWLEDGE: The proposed method achieves comparable accuracy to state-of-the-art methods with fewer pre-treatment planning CT images, which holds potential for application in precise image-guided radiation therapy.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Pele , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada Quadridimensional/métodos , Pele/diagnóstico por imagem , Inalação , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Expiração/fisiologia , Imageamento Tridimensional/métodos , Respiração , Tomografia Computadorizada por Raios X/métodos
14.
Med Biol Eng Comput ; 62(6): 1733-1749, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38363487

RESUMO

Chronic obstructive pulmonary disease (COPD) is a common lung disease that can lead to restricted airflow and respiratory problems, causing a significant health, economic, and social burden. Detecting the COPD stage can provide a timely warning for prompt intervention in COPD patients. However, existing methods based on inspiratory (IN) and expiratory (EX) chest CT images are not sufficiently accurate and efficient in COPD stage detection. The lung region images are autonomously segmented from IN and EX chest CT images to extract the 1 , 781 × 2 lung radiomics and 13 , 824 × 2 3D CNN features. Furthermore, a strategy for concatenating and selecting features was employed in COPD stage detection based on radiomics and 3D CNN features. Finally, we combine all the radiomics, 3D CNN features, and factor risks (age, gender, and smoking history) to detect the COPD stage based on the Auto-Metric Graph Neural Network (AMGNN). The AMGNN with radiomics and 3D CNN features achieves the best performance at 89.7 % of accuracy, 90.9 % of precision, 89.5 % of F1-score, and 95.8 % of AUC compared to six classic machine learning (ML) classifiers. Our proposed approach demonstrates high accuracy in detecting the stage of COPD using both IN and EX chest CT images. This method can potentially establish an efficient diagnostic tool for patients with COPD. Additionally, we have identified radiomics and 3D CNN as more appropriate biomarkers than Parametric Response Mapping (PRM). Moreover, our findings indicate that expiration yields better results than inspiration in detecting the stage of COPD.


Assuntos
Redes Neurais de Computação , Doença Pulmonar Obstrutiva Crônica , Tomografia Computadorizada por Raios X , Humanos , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Tomografia Computadorizada por Raios X/métodos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Inalação/fisiologia , Expiração/fisiologia , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Aprendizado de Máquina
15.
Respir Physiol Neurobiol ; 324: 104241, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38417565

RESUMO

Motor behaviors such as breathing required temporal coordination of different muscle groups to insured efficient ventilation and provide oxygen to the body. This action is the result of interactions between neural networks located within the brainstem. Inspiration and expiration depend at least in part on interactions between two separate oscillators: inspiration is driven by a neural network located in the preBötzinger complex (PreBötC) and active expiration is driven by a network in the parafacial respiratory group (pFRG). Neurons of the pFRG are silent at rest and become active when the respiratory drive increased. This study investigated the temporal coordination between the brainstem respiratory network and the lumbar spinal network that generates spontaneous activities that is different of the induced fictive locomotion. The remaining question is how these activities coordinate early during the development. Results of this study show that brainstem networks contribute to the temporal coordination of the lumbar spontaneous activity during inspiration since lumbar motor activity occurs exclusively during the expiratory time. This study also investigated the role of the ß-noradrenergic modulation on the respiratory activities. ß-noradrenergic receptors activation increased the frequency of the double bursts and increased expiratory activity at the lumbar level. These results suggest interactions between brainstem and spinal networks and reveal a descending drive that may contribute to the coordination of the respiratory and lumbar spontaneous activities.


Assuntos
Tronco Encefálico , Expiração , Animais , Camundongos , Animais Recém-Nascidos , Isoproterenol , Expiração/fisiologia , Tronco Encefálico/fisiologia , Medula Espinal/fisiologia
16.
J Speech Lang Hear Res ; 67(3): 729-739, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38324264

RESUMO

PURPOSE: Expiratory muscle strength training (EMST) is increasingly being used to treat voice, cough, and swallowing deficits in a wide range of conditions. However, a multitude of aero-resistive EMST models are commercially available, and the absence of side-by-side comparative data interferes with clinicians' ability to assess which model is best suited to a particular client's needs. The primary aim of this research was to test and compare the pressure and flow parameters of six currently available EMST models to help inform clinical decision making. METHOD: We identified and tested five devices of each of six different EMST models to generate benchmark data for minimum trigger pressures across settings. The reliability was tested within each device and between five devices of the same model across settings using coefficient of variation. RESULTS: All six models required higher pressures to initiate flow at the highest setting compared to the lowest setting, as expected. Detailed descriptive statistics for each model/setting combination include average flow-triggering pressure for each model/setting and the variability across trials within a device and across devices of the same model. From these, ranked order of the least to most stable EMST model was derived. CONCLUSIONS: Systematic testing of several commercially available expiratory resistance training devices yielded clinical benchmarks and reliability data to aid clinicians in selecting an appropriate therapy device and regimen for a client based on their available airflow and air pressure as well as reliability of the device. These findings allow clinicians to directly compare key parameters across EMST devices.


Assuntos
Expiração , Treinamento Resistido , Humanos , Reprodutibilidade dos Testes , Expiração/fisiologia , Terapia Respiratória , Força Muscular/fisiologia
17.
Respir Investig ; 62(2): 258-261, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38241959

RESUMO

We previously reported that laryngeal widening led to improved exercise tolerance in COPD. However, it is not clear whether laryngeal narrowing occurs as a compensatory response to tracheal movement or is affected by posture. Here, we report the case of an advanced COPD patient whose more prolonged expiration in a head-forward leaning position compared with that in a neck-extended position occurred with an excessive duration of severe laryngeal narrowing without tracheal obstruction, which led to exercise intolerance with expiratory mechanical constraints. This case provided useful insights into the regulation of the upper airway with body positioning for improving exercise tolerance.


Assuntos
Obstrução das Vias Respiratórias , Doença Pulmonar Obstrutiva Crônica , Humanos , Posicionamento do Paciente , Expiração/fisiologia , Obstrução das Vias Respiratórias/etiologia , Traqueia
18.
Sci Rep ; 14(1): 1562, 2024 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-38238422

RESUMO

Respiration stands as a vital process reflecting physiological and pathological human health status. Exhaled breath analysis offers a facile, non-invasive, swift, and cost-effective approach for diagnosing and monitoring diseases by detecting concentration changes of specific biomarkers. In this study, we employed Polyethylene oxide/copper (I) oxide composite nanofibers (PCNFs), synthesized via the electrospinning method as the sensing material to measure ethanol levels (1-200 ppm) in an exhaled breath simulator environment. The integrated contact-separation triboelectric nanogenerator was utilized to power the self-powered PCNFs exhaled breath sensor. The PCNFs-based gas sensor demonstrates promising results with values of 0.9 and 3.2 for detecting 5 ppm and 200 ppm ethanol, respectively, in the presence of interfering gas at 90% relative humidity (RH). Notably, the sensor displayed remarkable ethanol selectivity, with ratios of 10:1 to methanol and 25:1 to acetone. Response and recovery times for 200 ppm ethanol at 90 RH% were rapid, at 2.7 s and 5.8 s, respectively. The PCNFs-based exhaled breath sensor demonstrated consistent and stable performance in practical conditions, showcasing its potential for integration into wearable devices. This self-powered breath sensor enabling continuous monitoring of lung cancer symptoms and facilitating compliance checks with legal alcohol consumption limits.


Assuntos
Etanol , Expiração , Humanos , Expiração/fisiologia , Umidade , Respiração , Sistema Respiratório
19.
J Clin Monit Comput ; 38(1): 69-75, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37917211

RESUMO

INTRODUCTION: The intermittent intrapulmonary deflation (IID) technique is a recent airway clearance technique that intends to delay the onset of expiratory flow limitation (EFL) during exhalation. We showed in a previous study that IID increased the expiratory volume of COPD patients compared to quiet breathing and positive expiratory pressure (PEP) therapy. We hypothesized that it was due to the attenuation of the EFL. OBJECTIVES: To verify the physiologic effects of IID and PEP techniques on EFL with a mechanical lung model. METHODS: A mechanical lung model was created to assess the effects of IID and PEP techniques. The thorax was simulated by a plexiglas box in which an adult test lung was connected. A calibration syringe simulated the inspiratory phase. Later, with activation of the IID, the expiratory phase was driven by the deflation generated by the device. With PEP, the expiration occurred maintaining an expiratory pressure between 5 and 10 cmH2O. A pneumotachograph and a pressure transducer were placed in series for flow, volumes and pressure measurements. RESULTS: The model reproduced physiological characteristics of EFL. However, the deflation of the model was slowed by IID and PEP, and flow remained almost constant, so flow limitation was reduced. CONCLUSION: The IID and PEP attenuate EFL and increase exhaled volume in the in vitro model.


Assuntos
Expiração , Pulmão , Adulto , Humanos , Expiração/fisiologia , Respiração Artificial/métodos
20.
J Bodyw Mov Ther ; 36: 425-431, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37949595

RESUMO

INTRODUCTION: Deficits in respiratory function of patients with Parkinson's disease contribute to aspiration pneumonia, one of the main causes of mortality in this population. The aim of this study was to evaluate the effects of functional training, bicycle exercise, and exergaming on respiratory function of elderly with Parkinson's disease. METHODS: A randomized clinical trial with single blinding was conducted in a public reference outpatient clinic for the elderly. The participants were randomly assigned to three groups. Group 1 was submitted to functional training (n = 18); group 2 performed bicycle exercise (n = 20), and group 3 trained with Kinect Adventures exergames (n = 20). The sessions performed lasted 8 weeks with a frequency of three 50-min sessions per week. The primary outcome was the forced expiratory volume in the first second; and the secondary outcomes were forced vital capacity, peak expiratory flow, and maximum inspiratory and expiratory pressures. RESULTS: The interventions performed did not improve the forced expiratory volume in the first second, forced vital capacity, and peak expiratory flow. However, group 2 improved (p = 0.03) maximum expiratory pressure (from 65.5cmH2O to 73.1cmH2O) (effect size 0.47), and group 3 increased (p = 0.03) maximum inspiratory pressure (from -61.3cmH2O to -71.6cmH2O) (effect size 0.53). CONCLUSIONS: No effect was found on lung volume, forced respiratory flow and capacity of the participants with Parkinson's disease submitted to three different modalities of motor training. However, bicycle exercise and exergaming have improved expiratory and inspiratory muscle strength, respectively. NCT02622737.


Assuntos
Doença de Parkinson , Humanos , Idoso , Exercícios Respiratórios , Respiração , Expiração/fisiologia , Exercício Físico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA