Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.571
Filtrar
1.
Molecules ; 29(12)2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38930920

RESUMO

A promising method was established for the determination of nine halobenzoquinones (HBQs) in potable water by membrane solid-phase extraction (MSPE) pretreatment and the liquid chromatography-mass spectrometry (LC-MS) method. A 500 mL water sample was taken for enrichment by the SDB-RPS membrane, which was previously activated by methanol and ultrapure water. The sample was eluted with methanol and re-dissolved with the initial mobile phase after nitrogen blowing. Then, it was detected in negative ion mode using the working curve, and HBQs were quantified by the external standard method. The linearity was satisfactory in the concentration range of 4-1000 ng/L, with correlation coefficients of 0.9963~0.9994. The recoveries were 73.5~126.6% at three spiked levels, with relative standard deviations (RSDs) of 6.8~15.5%. The limits of detection (LOD, S/N = 3) values were 0.1~0.7 ng/L. The results demonstrate that the MSPE-LC-MS method is reliable, rapid, and sensitive for the simultaneous analysis of nine HBPs in potable water.


Assuntos
Benzoquinonas , Água Potável , Extração em Fase Sólida , Extração em Fase Sólida/métodos , Cromatografia Líquida/métodos , Benzoquinonas/química , Benzoquinonas/análise , Água Potável/análise , Água Potável/química , Espectrometria de Massas/métodos , Limite de Detecção , Poluentes Químicos da Água/análise , Espectrometria de Massa com Cromatografia Líquida
2.
Molecules ; 29(12)2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38930985

RESUMO

The abuse and irrational use of tetracyclines (TCs) in human medicine and animal husbandry has become a serious concern, affecting the ecological environment and human health. The aim of this study was to develop a sensitive and selective method using fully automatic solid-phase extraction coupled with ultra-performance liquid chromatography-tandem mass spectrometry for the determination of twelve TCs in water. Four isotope-labeled internal standards for TCs were used to correct matrix effects. Several parameters affecting extraction efficiency were systematically optimized, and the optimum experimental conditions found were 1.0 L water sample with 0.5 g/L Na2EDTA (pH 3.0) extracted and enriched by CNW HLB cartridge and eluted by 4 mL of acetone:methanol (v/v, 1:1). The enrichment factors were up to 798-1059 but only requiring about 60 min per six samples. Under the optimized conditions, the linearity of the method ranged from 0.2 to 100 µg/L for 12 TCs, the detection limits were as low as 0.01-0.15 ng/L, and the recoveries were in the range of 70%-118%, with relative standard deviations less than 15%. The developed method can be successfully utilized for the determination of 12 TCs in pure water, tap water, river water, and mariculture seawater. In summary, three and six TCs were detected in river water and mariculture seawater, respectively, with total concentrations of 0.074-0.520 ng/L (mean 0.248 ng/L) and 0.792-58.369 ng/L (12.629 ng/L), respectively. Tetracycline (TC) and oxytetracycline (OTC) were the dominant TCs in river water, while doxytetracycline (DXC) and OTC were dominant in mariculture seawater.


Assuntos
Água Potável , Extração em Fase Sólida , Espectrometria de Massas em Tandem , Tetraciclinas , Poluentes Químicos da Água , Espectrometria de Massas em Tandem/métodos , Extração em Fase Sólida/métodos , Tetraciclinas/análise , Poluentes Químicos da Água/análise , Água Potável/análise , Água Potável/química , Cromatografia Líquida de Alta Pressão/métodos , Limite de Detecção
3.
Anal Methods ; 16(25): 4104-4115, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38855940

RESUMO

Fluoroquinolone (FQ) antibiotics, one of the leading environmental pollutants, have ecotoxic effects that can accumulate through ecosystems and harm human health. The determination of FQs is still difficult due to the complex matrix, many interfering factors, and low concentration. Hence, a magnetic microporous organic network (MON) composite denoted as Fe3O4@MON-NH2@CM-ß-CD with excellent FQ adsorption performance was prepared by ß-CD covalent modification of a MON. Based on the existence of π-π packing, hydrophobic interaction, and hydrogen bonding between Fe3O4@MON-NH2@CM-ß-CD and FQs, a new magnetic solid phase extraction (MSPE) method for the enrichment of FQs was developed. Under optimized MSPE conditions, five FQs were detected by HPLC-UV with good linearity (R2 ≥ 0.9989) in the range of 0.02-1 µg mL-1, and detection limits (S/N = 3) in the range of 0.0014-0.0023 µg mL-1. The satisfactory recoveries ranged from 93.1 to 116.2% with RSDs lower than 8.39% when applied to actual environmental water samples. These results revealed that Fe3O4@MON-NH2@CM-ß-CD as an adsorbent for MSPE had excellent performance for FQ extraction from real samples, and the MON material types were expanded through the functionalization of MONs, which would have great potential for further application in various analytical methods.


Assuntos
Antibacterianos , Fluoroquinolonas , Extração em Fase Sólida , Poluentes Químicos da Água , beta-Ciclodextrinas , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/química , Fluoroquinolonas/análise , Fluoroquinolonas/química , Fluoroquinolonas/isolamento & purificação , Extração em Fase Sólida/métodos , Antibacterianos/análise , Antibacterianos/química , beta-Ciclodextrinas/química , Porosidade , Adsorção , Cromatografia Líquida de Alta Pressão/métodos , Limite de Detecção
4.
Sci Rep ; 14(1): 13064, 2024 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844596

RESUMO

This study aimed to investigate carbamate pesticide residues in different varieties of date palm fruits in the UAE, utilizing UHPLC-MS/MS. For sample preparation and clean-up, the efficiency and performance of different QuEChERS dispersive solid-phase extraction kits were compared. Precision and recovery were assessed at 10 µg kg-1 for the three kits, revealing that Kit 2 demonstrated the best performance. The selected QuEChERS method was validated to detect 14 carbamate residues in 55 date samples. The method exhibited strong linearity with R2 > 0.999 and low LOD (0.01-0.005 µg kg-1) and LOQ (0.003-0.04 µg kg-1). Excellent accuracy (recovery: 88-106%) and precision (RSD: 1-11%) were observed, with negligible matrix effect (- 4.98-13.26%). All samples contained at least one carbamate residue. While most detected residues were below their MRLs, carbosulfan was found in 21 samples, propoxur in 2 samples, and carbofuran in 1 sample above their MRLs. The hazard index (HI) was calculated for carbosulfan, phenmedipham, carbaryl, propoxur, carbofuran, and methomyl to assess potential health risks for date consumers. All HI values were below the safety limit of 1.0, indicating that the consumption of dates does not pose a non-carcinogenic health risk for adults and children.


Assuntos
Carbamatos , Frutas , Resíduos de Praguicidas , Phoeniceae , Espectrometria de Massas em Tandem , Phoeniceae/química , Resíduos de Praguicidas/análise , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Carbamatos/análise , Frutas/química , Humanos , Medição de Risco , Extração em Fase Sólida/métodos , Contaminação de Alimentos/análise
5.
Wei Sheng Yan Jiu ; 53(3): 447-454, 2024 May.
Artigo em Chinês | MEDLINE | ID: mdl-38839587

RESUMO

OBJECTIVE: To develop and validate a solid phase extraction-ultra-high performance liquid chromatography-tandem mass spectrometry method for the determination of six bisphenols(bisphenol S, bisphenol F, bisphenol A, 2, 2'-methylenediphenol, bisphenol AF, bisphenol AP) in urine. METHODS: After enzymolysis of urine sample, the target substances were quickly purified and extracted by WAX solid phase extraction column. On ACQUITY BEH C_(18) column(2.1 mm×100 mm, 1.7 µm), the mobile phase of water and methanol was used to separate. Finally, multi-reaction detection was carried out under electrospray negative ion scanning, and quantification was carried out by internal standard method. RESULTS: The correlation coefficients(r) of the target compounds were all more than 0.998 in the range of 0.1-50.0 ng/mL, the linearity was good, and the detection limits were all lower than 0.1 ng/mL. The recoveries of the three standard concentrations(0.5, 5.0 and 50.0 ng/mL) were all between 80% and 120%, and the relative standard deviation was less than 20%(n=5). The standard reference material was detected and the concentration was within the reference range. CONCLUSION: This method can be used to detect six bisphenols in urine quickly and accurately, is suitable for the trace analysis of bisphenol compounds in human urine.


Assuntos
Compostos Benzidrílicos , Fenóis , Espectrometria de Massas em Tandem , Humanos , Fenóis/urina , Fenóis/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Compostos Benzidrílicos/urina , Extração em Fase Sólida/métodos , Sulfonas/urina
6.
Anal Chim Acta ; 1312: 342780, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38834272

RESUMO

BACKGROUND: The convenient preparation and application of functionalized organic-inorganic hybrid monolithic materials have obtained substantial interest in the pretreatment of complex samples by solid-phase extraction (SPE). Compared to the in-tube solid-phase microextraction in fused-silica capillaries, micro SPE in plastic pipette tips have fascinating merits for the easily operated enrichment of trace target analytes from biological samples. However, the poor compatibility of organic-inorganic hybrid monoliths with plastics leads to the rare appearance of commercial hybrid monolithic pipette tips (HMPTs). Therefore, how to synthesize the organic-inorganic hybrid monolithic materials with better extraction performance in plastic pipette tips becomes a challenge. RESULTS: We develop a facile and cheap strategy to immobilize organic-inorganic hybrid monoliths in pipette tips. Melamine sponge was employed as the supporting skeleton to in situ assemble amine- and thiol-bifunctionalized hybrid monolithic material via "one pot" in a pipette tip, and gold nanoparticles (GNPs) and thiol-modified aptamer against human α-thrombin were sequentially attached to the hybrid monolith within the HMPTs. The average coverage density of the aptamer with GNPs as an intermediary reached as high as 818.5 pmol µL-1. The enriched thrombin concentration was determined by a sensitive enzymatic chromogenic assay with the limit of detection of 2 nM. The extraction recovery of thrombin at 10 nM in human serum was 86.1 % with a relative standard deviation of 6.1 %. This proposed protocol has been applied to the enrichment and determination of thrombin in real serum sample with strong anti-interference ability, low limit of detection and high recovery. SIGNIFICANCE: The amine- and thiol-bifunctionalized HMPTs prepared with sponge as the skeleton frame provided a novel substrate material to decorate aptamers for efficient enrichment of proteins. This enlightens us that we can take advantage of the tunability of sponge assisted HMPTs to produce and tailor a variety of micro SPE pipette tips for broader applications on the analysis of trace targets in complex biological, clinic and environmental samples.


Assuntos
Aptâmeros de Nucleotídeos , Trombina , Triazinas , Triazinas/química , Triazinas/isolamento & purificação , Aptâmeros de Nucleotídeos/química , Humanos , Trombina/análise , Trombina/isolamento & purificação , Ouro/química , Nanopartículas Metálicas/química , Extração em Fase Sólida/métodos
7.
J Chromatogr A ; 1729: 465030, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38838449

RESUMO

Exposure to tobacco smoke is highly correlated to the incidence of different types of cancer due to various carcinogenic compounds present in such smoke. Aromatic amines, such as 1-naphthylamine (1-NA) and 2-naphthylamine (2-NA), are produced in tobacco burning and are linked to bladder cancer. Miniaturized solid phase extraction techniques, such as microporous membrane solid phase extraction (MMSPE), have shown potential for the extraction of aromatic compounds. In this study, a bioanalytical method for the determination of 1-NA and 2-NA in human urine was developed using polypropylene microporous membranes as a sorptive phase for MMSPE. Urine samples were hydrolyzed with HCl for 1 h at 80 °C, after which pH was adjusted to 10. Ultrasound-assisted MMSPE procedure was optimized by factorial design as follows. To each sample, 750 µL of methanol was added, and ultrasound-assisted MMSPE was conducted for 1 h with four devices containing seven 2 mm polypropylene membrane segments. After extraction, the segments were transferred to 400 µL of hexane, and desorption was conducted for 30 min. Extracts were submitted to a simple and fast microwave-assisted derivatization procedure, by the addition of 10 µL of PFPA and heating at 480 W for 3 min, followed by clean-up with phosphate buffer pH 8.0 and GC-MS/MS analysis. Adequate linearity was obtained for both analytes in a range from 25 to 500 µg L-1, while the multiple reaction monitoring approach provided satisfactory selectivity and specificity. Intra-day (n = 6) and inter-day (n = 5) precision and accuracy were satisfactory, below 15 % and between 85 and 115 %, respectively. Recovery rates found were 91.9 and 58.4 % for 1-NA and 2-NA, respectively, with adequate precision. 1-NA was found in first-hand smokers' urine samples in a concentration range from 20.98 to 89.09 µg in 24 h, while it could be detected in second-hand smoker's urine samples, and 2-NA detected in all first and second-hand smokers' urine samples. The proposed method expands the applicability of low cost MMSPE devices to aromatic amines and biological fluids.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Limite de Detecção , Polipropilenos , Extração em Fase Sólida , Espectrometria de Massas em Tandem , Humanos , Polipropilenos/química , Espectrometria de Massas em Tandem/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Extração em Fase Sólida/métodos , Carcinógenos/análise , Carcinógenos/isolamento & purificação , Reprodutibilidade dos Testes , 1-Naftilamina/análogos & derivados , 1-Naftilamina/química , Membranas Artificiais , 2-Naftilamina/análogos & derivados , 2-Naftilamina/química , Porosidade , Fumantes
8.
J Chromatogr A ; 1729: 465040, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38838450

RESUMO

In this work, porous polyimide microfibers (PI-µF) were prepared by high-pressure wet spinning method, and successfully applied as adsorbents for solid phase extraction (SPE) of fluoroquinolones (FQs) in water and food samples. The PI-µFs of ∼10, 25, 50, 100 µm in diameter could be controlled by the inner diameter of quartz capillary nozzles. The flow resistance of SPE cartridges packed with 10 µm PI microfiber (10-PI-µF) and 25-PI-µF was comparable to or even lower than that of commercial SPE cartridges, while the flow resistance of 50-PI-µF and 100-PI-µF SPE cartridges was increased obviously due to tiny broken pieces. The 10-PI-µF and 25-PI-µF have a specific surface area of 102 m2 g-1 and 76 m2 g-1, mesopores of 22-32 nm, and large breakthrough volume of 110 mL/5 mg and 85 mL/5 mg for FQs, while the 50-PI-µF and 100-PI-µF had much lower specific surface area and hardly had retention for FQs. FQs from tap water, egg and milk samples were then extracted by PI-µF SPE, and analyzed by high performance liquid chromatography-fluorescence detector (HPLC-FLD). SPE parameters as type of elution solvent, elution solvent volume, pH value of sample solution, flow rate of sample solution, and breakthrough volume were first optimized in detail. Under the optimal conditions, the PI-µF SPE/HPLC-FLD method showed high recoveries (96.8%-107%), wide linearity (0.05-50 µg L-1, or 0.01-10 µg L-1), high determination coefficients (R2 ≥0.9992), and low limits of detection (LODs, 0.005-0.014 µg L-1). For the real tap water, egg and milk samples, the recoveries and RSDs were 81-119% and 0.8-9.8%, respectively. The results show that porous microfiber up to 25 µm in diameter is a promising solid-phase extraction adsorbent with the lowest flow resistance that can be used for trace organic pollutants in water and food samples.


Assuntos
Fluoroquinolonas , Limite de Detecção , Leite , Extração em Fase Sólida , Poluentes Químicos da Água , Extração em Fase Sólida/métodos , Fluoroquinolonas/análise , Fluoroquinolonas/isolamento & purificação , Fluoroquinolonas/química , Porosidade , Leite/química , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação , Poluentes Químicos da Água/química , Cromatografia Líquida de Alta Pressão/métodos , Animais , Ovos/análise , Adsorção , Pressão , Contaminação de Alimentos/análise , Resinas Sintéticas/química , Análise de Alimentos/métodos , Reprodutibilidade dos Testes
9.
Artigo em Inglês | MEDLINE | ID: mdl-38851151

RESUMO

In this study, a magnetic three-dimensional nano-composite based on Rubber-Fe3O4@Ni-Co Layered double hydroxide derived from ZIF-67 template was synthesized by a hydrothermal method. The proposed nano-composite was used as a sorbent for the enrichment of trace amounts of anti-cancer drugs (dasatinib and erlotinib hydrochloride) from plasma samples followed by determination using high-performance liquid chromatographic analysis (HPLC-UV). The synthesized nano-sorbent was characterized by X-ray diffraction, field emission scanning electron microscopy, Fourier transform infrared spectroscopy, vibrating-sample magnetometer, Brunauer-Emmett-Teller surface analysis, Barrett-Joyner-Halenda pore size analysis and energy dispersive X-ray spectroscopy. Under optimal experimental conditions, factors affecting on extraction efficiency such as pH, ionic strength, extraction temperature and time, desorption solvent and time, the limit of detection (LODs) and the limit of quantification (LOQs) were obtained as 0.6, 2 µg/L for both of dasatinib and erlotinib, respectively. Also, linear range of the method were 2-500 and 2-1000 µg/L for dasatinib and erlotinib, respectively. Relative standard deviations (RSD%) for the repeatability of extraction on sorbent to sorbent were obtained as 3.59, 1.97 %, and one sorbent reusability were investigated and relative standard deviation values were obtained 5.35, 3.30 % for dasatinib and erlotinib, respectively.


Assuntos
Antineoplásicos , Cloridrato de Erlotinib , Limite de Detecção , Borracha , Borracha/química , Antineoplásicos/sangue , Antineoplásicos/química , Cromatografia Líquida de Alta Pressão/métodos , Reprodutibilidade dos Testes , Humanos , Cloridrato de Erlotinib/sangue , Cloridrato de Erlotinib/química , Modelos Lineares , Dasatinibe/sangue , Dasatinibe/química , Hidróxidos/química , Imidazóis/química , Imidazóis/sangue , Adsorção , Extração em Fase Sólida/métodos , Cobalto/química , Cobalto/sangue , Nanoestruturas/química , Zeolitas
10.
J Chromatogr A ; 1729: 465012, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38852264

RESUMO

Acrylamide and N, N-methylene bis acrylamide are most commonly used monomer and crosslinker compounds employed in synthesis of super absorbent hydrogels. When applied as soil conditioners, there are apprehensions that these hydrogels degrade over time and thus may release the toxic monomers in the soil. A method was thus developed using Liquid Chromatography tandem mass spectrometry (LC-MS/MS) for the trace level quantification of acrylamide (AD), acrylic acid (AA) and N,N-methylene-bis-acrylamide (MBA) in sandy loam soil amended by two test hydrogels the Pusa Hydrogel and SPG 1118 hydrogel prepared using AD and MBA. The MRM (multiple reaction monitoring) transitions were optimized for both the compounds. Soil samples were extracted using dispersive solid-phase extraction (dSPE) with a modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) technique, employing acetonitrile. All analytes were quantified at trace levels within a five-minute run using UHPLC equipped with a C-18 column. Single laboratory validation of the developed method in soil matrix was conducted based on specificity, linearity, sensitivity, accuracy, precision, matrix effect and measurement of uncertainty. LC-MS/MS exhibited a linear response in the concentration range of 0.001 to 1 µg mL-1, with correlation coefficient >+0.99. Acceptable recovery (within 70-120 %) with repeatability (%RSD ≤20 %) was obtained at 0.01 to 1 µg g-1 fortification levels. LOQ (Limit of quantification) of the method for AD, AA and MBA in soil matrix were 0.05, 1 and 0.01 µg g-1, respectively. Both intra-laboratory repeatability and intermediate precision at LOQ suggested well acceptable precise (HorRat≈ 0.3) method for quantification. Matrix enhancement effect was observed in the order: AA>AD>MBA. The Expanded Uncertainty (EU) in soil matrix at LOQ was 21.64 %, 28 % and 19 % for AD, AA and MBA respectively. Groundnut and wheat grown with application of the hydrogels showed no detectable residues of monomers in soil samples (total n = 60) near the root zone at the time of crop harvesting.


Assuntos
Acrilamida , Acrilamidas , Acrilatos , Poluentes do Solo , Solo , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Acrilatos/análise , Acrilatos/química , Acrilamida/análise , Solo/química , Acrilamidas/química , Acrilamidas/análise , Poluentes do Solo/análise , Extração em Fase Sólida/métodos , Reprodutibilidade dos Testes , Limite de Detecção , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Hidrogéis/química , Espectrometria de Massa com Cromatografia Líquida
11.
Molecules ; 29(11)2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38893376

RESUMO

Ellagic acid (EA) is a natural polyphenol and possesses excellent in vivo bioactivity and antioxidant behaviors, which play an important role in the treatment of oxidative stress-related diseases, such as cancer. Additionally, EA is also known as a skin-whitening ingredient. The content of EA would determine its efficacy. Therefore, the accurate analysis of EA content can provide more information for the scientific consumption of EA-rich foods and cosmetics. Nevertheless, the analysis of EA in these samples is challenging due to the low concentration level and the presence of interfering components with high abundance. Molecularly imprinted polymers are highly efficient pretreatment materials in achieving specific recognition of target molecules. However, the traditional template molecule (EA) could not be absolutely removed. Hence, template leakage continues to occur during the sample preparation process, leading to a lack of accuracy in the quantification of EA in actual samples, particularly for trace analytes. In addition, another drawback of EA as an imprinting template is that EA possesses poor solubility and a high price. Gallic acid (GA), called dummy templates, was employed for the synthesis of MIPs as a solution to these challenges. The approach used in this study was boronate affinity-based oriented surface imprinting. The prepared dummy-imprinted nanoparticles exhibited several significant advantages, such as good specificity, high binding affinity ((4.89 ± 0.46) × 10-5 M), high binding capacity (6.56 ± 0.35 mg/g), fast kinetics (6 min), and low binding pH (pH 5.0) toward EA. The reproducibility of the dummy-imprinted nanoparticles was satisfactory. The dummy-imprinted nanoparticles could still be reused even after six adsorption-desorption cycles. In addition, the recoveries of the proposed method for EA at three spiked levels of analysis in strawberry and pineapple were 91.0-106.8% and 93.8-104.0%, respectively, which indicated the successful application to real samples.


Assuntos
Ácido Elágico , Impressão Molecular , Extração em Fase Sólida , Ácido Elágico/química , Extração em Fase Sólida/métodos , Impressão Molecular/métodos , Ácidos Borônicos/química , Polímeros Molecularmente Impressos/química , Análise de Alimentos/métodos , Nanoestruturas/química
12.
Anal Methods ; 16(24): 3968-3982, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38853581

RESUMO

Concerns have been raised about synthetic cannabinoids (SCs), which are among the most often trafficked and used illegal substances. An analytical method that holds promise for determining illicit drug use in the general population is wastewater-based epidemiology (WBE). Unfortunately, the concentration of SCs in wastewater is often extremely low on account of their hydrophobic nature, thus presenting a significant obstacle to the accurate detection and quantification of SCs using WBE. In this study, we present novel magnetic nanomaterials as amphiphilic adsorbents for pretreatment of wastewater using magnetic solid phase extraction (MSPE). Polydopamine-modified Fe3O4 nanoparticles were used as the magnetic core and further functionalized with poly(divinylbenzene-N-vinylpyrrolidone). Coupled with UHPLC-MS/MS analysis, an analytical method to simultaneously detect nine SCs at trace-levels in wastewater was developed and validated, enriching 50 mL wastewater to 100 µL with limits of detection (LOD) being 0.005-0.5 ng L-1, limits of quantification (LOQ) being 0.01-1.0 ng L-1, recoveries ranging from 73.99 to 110.72%, and the intra- and inter-day precision's relative standard deviations less than 15%. In comparison to the time-consuming conventional column-based solid phase extraction, the entire MSPE procedure from sample pre-treatment to data acquisition could be finished in one hour, thus largely facilitating the WBE method for drug surveillance and control.


Assuntos
Canabinoides , Indóis , Limite de Detecção , Polímeros , Extração em Fase Sólida , Espectrometria de Massas em Tandem , Águas Residuárias , Poluentes Químicos da Água , Indóis/química , Polímeros/química , Águas Residuárias/química , Águas Residuárias/análise , Extração em Fase Sólida/métodos , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/química , Espectrometria de Massas em Tandem/métodos , Canabinoides/análise , Canabinoides/química , Nanopartículas de Magnetita/química , Cromatografia Líquida de Alta Pressão/métodos , Pirrolidinonas/química , Pirrolidinonas/análise , Adsorção
13.
Anal Methods ; 16(24): 3810-3814, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38855885

RESUMO

A cysteine-based fluorous trapping reagent, Rf8CYS, was developed. Rf8CYS formed adducts with soft and hard electrophilic reactive metabolites. These fluorous-tagged adducts were purified via both fluorous solid-phase extraction and the direct injection method. The highly sensitive mass spectrometric detection of an unprecedented adduct of the ticlopidine metabolite was realized.


Assuntos
Cisteína , Extração em Fase Sólida , Cisteína/química , Cisteína/metabolismo , Cisteína/análise , Extração em Fase Sólida/métodos , Indicadores e Reagentes/química , Espectrometria de Massas/métodos , Humanos
14.
Int J Mol Sci ; 25(11)2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38891955

RESUMO

There is great concern in equine sport over the potential use of pharmaceutical agents capable of editing the genome or modifying the expression of gene products. Synthetic oligonucleotides are short, single-stranded polynucleotides that represent a class of agents capable of modifying gene expression products with a high potential for abuse in horseracing. As these substances are not covered by most routine anti-doping analytical approaches, they represent an entire class of compounds that are not readily detectable. The nucleotide sequence for each oligonucleotide is highly specific, which makes targeted analysis for these agents problematic. Accordingly, we have developed a non-targeted approach to detect the presence of specific product ions that are not naturally present in ribonucleic acids. Briefly, serum samples were extracted using solid-phase extraction with a mixed-mode cartridge following the disruption of protein interactions to isolate the oligonucleotides. Following the elution and concentration steps, chromatographic separation was achieved utilizing reversed-phase liquid chromatography. Following an introduction to a Thermo Q Exactive HF mass spectrometer using electrospray ionization, analytes were detected utilizing a combination of full-scan, parallel reaction monitoring and all ion fragmentation scan modes. The limits of detection were determined along with the accuracy, precision, stability, recovery, and matrix effects using a representative 13mer oligonucleotide. Following method optimization using the 13mer oligonucleotide, the method was applied to successfully detect the presence of specific product ions in three unique oligonucleotide sequences targeting equine-specific transcripts.


Assuntos
Oligonucleotídeos , Animais , Cavalos/sangue , Oligonucleotídeos/sangue , Dopagem Esportivo/prevenção & controle , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Extração em Fase Sólida/métodos , Limite de Detecção
15.
Methods Mol Biol ; 2817: 19-31, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38907144

RESUMO

Clinical and biological samples are often scarce and precious (e.g., rare cell isolates, microneedle tissue biopsies, small-volume liquid biopsies, and even single cells or organelles). Typical large-scale proteomic methods, where significantly higher protein amounts are analyzed, are not directly transferable to the analysis of limited samples due to their incompatibility with pg-, ng-, and low-µg-level protein sample amounts. Here, we report the on-microsolid-phase extraction tip (OmSET)-based sample preparation workflow for sensitive analysis of limited biological samples to address this challenge. The developed platform was successfully tested for the analysis of 100-10,000 typical mammalian cells and is scalable to allow for lower and larger protein amounts and more samples to be analyzed (i.e., higher throughput of analysis).


Assuntos
Proteômica , Extração em Fase Sólida , Fluxo de Trabalho , Proteômica/métodos , Humanos , Extração em Fase Sólida/métodos , Proteínas/análise , Proteoma/análise
16.
Anal Methods ; 16(23): 3784-3797, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38828558

RESUMO

Newly designed micro-solid phase extraction cartridges are now available, reflecting the increasing shift towards laboratory automation, especially in the clean-up step for the analysis of pesticide residues in food and feed. In the present study, the introduction of different sorbents on the newly designed PAL µSPE CTC cartridges was investigated for the removal of matrix interferents and the recovery of pesticides. Eight cartridges containing different sorbent combinations and different amounts were used including EMR-lipid (not activated), Z-sep, chitin, C18, PSA, and GCB. The evaluation of co-extractive removal for each cartridge showed that the optimal choice for removing fatty acids was the cartridges containing PSA and Z-sep as clean-up sorbents. However, the presence of C18 and EMR-lipid was still required for the removal of sterols and tocopherols. Two grams of sample, fish feed (FF) and rapeseed cake (RSC) were extracted using QuEChERS citrate buffer, followed by a freeze-out step. The recoveries and repeatability of QuEChERS using µ-SPE clean-up were evaluated for 216 pesticide residues (112 compounds analyzed by GC-MS/MS and 143 compounds by LC-MS/MS, from which 39 compounds were analyzed using both techniques). The best results, with recovery between 70 and 120% and RSD <20%, were achieved when FF samples were cleaned-up with 15 mg EMR-lipid and 20 mg MgSO4. This was achieved for 94% of GC-amenable compounds and 86% of LC-amenable compounds. In the case of RSC, the best results were seen when samples were cleaned-up with the cartridge containing only 20 mg Z-sep and 20 mg MgSO4. This was achieved for 88% of GC-amenable compounds and 90% of LC-amenable compounds. Although these cartridges yielded optimal results in terms of recovery, their use could require more instrument maintenance, especially for GC-MS/MS, due to the lower removal of co-extractives.


Assuntos
Ração Animal , Resíduos de Praguicidas , Microextração em Fase Sólida , Resíduos de Praguicidas/análise , Microextração em Fase Sólida/métodos , Ração Animal/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Contaminação de Alimentos/análise , Extração em Fase Sólida/métodos , Animais
17.
Sci Rep ; 14(1): 14479, 2024 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-38914553

RESUMO

Nucleic acid amplification testing has great potential for point-of-need diagnostic testing with high detection sensitivity and specificity. Current sample preparation is limited by a tedious workflow requiring multiple steps, reagents and instrumentation, hampering nucleic acid testing at point of need. In this study, we present the use of mixed cellulose ester (MCE) paper for DNA binding by ionic interaction under molecular crowding conditions and fluid transport by wicking. The poly(ethylene) glycol-based (PEG) reagent simultaneously provides the high pH for alkaline lysis and crowding effects for ionic binding of the DNA under high salt conditions. In this study, we introduce Paper-based Abridged Solid-Phase Extraction with Alkaline Poly(ethylene) Glycol Lysis (PASAP). The anionic mixed cellulose ester (MCE) paper is used as solid phase and allows for fluid transport by wicking, eliminating the need for pipetting skills and the use of a magnet to retain beads. Following the release of DNA from the cells due to the lytic activity of the PASAP solution, the DNA binds to the anionic surface of the MCE paper, concentrating at the bottom while the sample matrix is transported towards the top by wicking. The paper was washed by dipping it in 40% isopropanol for 10 s. After air-drying for 30 s, the bottom section of the paper (3 mm × 4 mm) was snapped off using the cap of a PCR tube and immersed in the colourimetric loop-mediated isothermal amplification (cLAMP) solution for direct amplification and colourimetric detection. The total sample processing was completed in 15 min and ready for amplification. cLAMP enabled the detection of 102 CFU/mL of Escherichia coli (E. coli) from culture media and the detection of E. coli in milk < 103 CFU/mL (10 CFU) after incubation at 68 °C for 60 min, demonstrating applicability of the method to complex biological samples.


Assuntos
Técnicas de Amplificação de Ácido Nucleico , Papel , Técnicas de Amplificação de Ácido Nucleico/métodos , Colorimetria/métodos , DNA , Extração em Fase Sólida/métodos , Polietilenoglicóis/química , DNA Bacteriano/isolamento & purificação , DNA Bacteriano/genética , Técnicas de Diagnóstico Molecular
18.
J Sep Sci ; 47(11): e2300915, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38847294

RESUMO

In this work, core-shell material with a special structure was designed and applied in solid-phase extraction (SPE) for non-steroidal anti-inflammatory drugs (NSAIDs) combined with high-performance liquid chromatography. Based on the advantages of core-shell ZIF-8@ZIF-67 (Zeolite imidazole ester framework materials [ZIFs]), effective derivatization treatment was carried out to partially vulcanize the original ZIFs, resulting in a special and new double-core-shell structural material CoS/ZIF-67/ZnS/ZIF-8 (ZIFs@ZnS@CoS) with porous surface and center hollow. The multiple forces caused by the rich chemical structure, the large specific surface area caused by the special pore structure, and the effective protection of the ZIFs core by sulfide shell make the designed material have higher extraction efficiency and longer service life, compared with ZIF-8@ZIF-67 and ZIF-8. At the same time, the established analytical method for non-steroidal drugs had a high recovery rate (98.93%-102.10%), low detection limit (0.11-0.27 µg/L), and wide linear range (1-200 µg/L) within a good correlation coefficient R2 (0.9978-0.9993). Satisfactory results were also obtained from the extraction of NSAIDs from the Yellow River water samples. These results indicate that the designed double-core-shell structure material can effectively exert its structural advantages and become a promising extraction material.


Assuntos
Anti-Inflamatórios não Esteroides , Extração em Fase Sólida , Anti-Inflamatórios não Esteroides/química , Anti-Inflamatórios não Esteroides/isolamento & purificação , Anti-Inflamatórios não Esteroides/análise , Extração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão , Propriedades de Superfície , Poluentes Químicos da Água/química , Poluentes Químicos da Água/isolamento & purificação , Poluentes Químicos da Água/análise , Tamanho da Partícula , Estruturas Metalorgânicas/química , Estrutura Molecular , Porosidade , Zeolitas/química , Adsorção , Imidazóis/química
19.
Se Pu ; 42(6): 508-523, 2024 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-38845512

RESUMO

Given continuous improvements in industrial production and living standards, the analysis and detection of complex biological sample systems has become increasingly important. Common complex biological samples include blood, serum, saliva, and urine. At present, the main methods used to separate and recognize target analytes in complex biological systems are electrophoresis, spectroscopy, and chromatography. However, because biological samples consist of complex components, they suffer from the matrix effect, which seriously affects the accuracy, sensitivity, and reliability of the selected separation analysis technique. In addition to the matrix effect, the detection of trace components is challenging because the content of the analyte in the sample is usually very low. Moreover, reasonable strategies for sample enrichment and signal amplification for easy analysis are lacking. In response to the various issues described above, researchers have focused their attention on immuno-affinity technology with the aim of achieving efficient sample separation based on the specific recognition effect between antigens and antibodies. Following a long period of development, this technology is now widely used in fields such as disease diagnosis, bioimaging, food testing, and recombinant protein purification. Common immuno-affinity technologies include solid-phase extraction (SPE) magnetic beads, affinity chromatography columns, and enzyme linked immunosorbent assay (ELISA) kits. Immuno-affinity techniques can successfully reduce or eliminate the matrix effect; however, their applications are limited by a number of disadvantages, such as high costs, tedious fabrication procedures, harsh operating conditions, and ligand leakage. Thus, developing an effective and reliable method that can address the matrix effect remains a challenging endeavor. Similar to the interactions between antigens and antibodies as well as enzymes and substrates, biomimetic molecularly imprinted polymers (MIPs) exhibit high specificity and affinity. Furthermore, compared with many other biomacromolecules such as antigens and aptamers, MIPs demonstrate higher stability, lower cost, and easier fabrication strategies, all of which are advantageous to their application. Therefore, molecular imprinting technology (MIT) is frequently used in SPE, chromatographic separation, and many other fields. With the development of MIT, researchers have engineered different types of imprinting strategies that can specifically extract the target analyte in complex biological samples while simultaneously avoiding the matrix effect. Some traditional separation technologies based on MIP technology have also been studied in depth; the most common of these technologies include stationary phases used for chromatography and adsorbents for SPE. Analytical methods that combine MIT with highly sensitive detection technologies have received wide interest in fields such as disease diagnosis and bioimaging. In this review, we highlight the new MIP strategies developed in recent years, and describe the applications of MIT-based separation analysis methods in fields including chromatographic separation, SPE, diagnosis, bioimaging, and proteomics. The drawbacks of these techniques as well as their future development prospects are also discussed.


Assuntos
Impressão Molecular , Humanos , Cromatografia de Afinidade/métodos , Extração em Fase Sólida/métodos , Ensaio de Imunoadsorção Enzimática
20.
Carbohydr Polym ; 339: 122257, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38823923

RESUMO

Traditional solid phase extraction (SPE) suffers from a lack of specific adsorption. To overcome this problem, a combination of adsorption method and molecular imprinting technology by polydopamine modification was proposed to realize specific recognition of target compounds in SPE, which is of great significance to improve the separation efficiency of SPE. Cellulose hydrogel beads were prepared by dual cross-linking curing method and modified with polydopamine to make them hydrophilic and biocompatible. Subsequently, cellulose hydrogel-based molecularly imprinted beads (MIBs) were synthesized by surface molecular imprinting technology and used as novel column fillers in SPE to achieve efficient adsorption (34.16 mg·g-1) with specific selectivity towards camptothecin (CPT) in 120 min. The simulation and NMR analysis revealed that recognition mechanism of MIBs involved hydrogen bond interactions and Van der Waals effect. The MIBs were successful used in separating CPT from Camptotheca acuminata fruits, exhibiting impressive adsorption capacity (1.19 mg·g-1) and efficient recovery of CPT (81.54 %). Thus, an environmentally friendly column filler for SPE was developed, offering a promising avenue for utilizing cellulose-based materials in the selective separation of natural products.


Assuntos
Camptotecina , Celulose , Hidrogéis , Impressão Molecular , Extração em Fase Sólida , Camptotecina/química , Camptotecina/isolamento & purificação , Celulose/química , Adsorção , Impressão Molecular/métodos , Hidrogéis/química , Extração em Fase Sólida/métodos , Camptotheca/química , Polímeros/química , Interações Hidrofóbicas e Hidrofílicas , Indóis/química , Frutas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA