Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24.295
Filtrar
1.
Cochrane Database Syst Rev ; 6: CD013366, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38940297

RESUMO

BACKGROUND: Peripherally inserted central catheters (PICCs) facilitate diagnostic and therapeutic interventions in health care. PICCs can fail due to infective and non-infective complications, which PICC materials and design may contribute to, leading to negative sequelae for patients and healthcare systems. OBJECTIVES: To assess the effectiveness of PICC material and design in reducing catheter failure and complications. SEARCH METHODS: The University of Queensland and Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL databases and the WHO ICTRP and ClinicalTrials.gov trials registers to 16 May 2023. We aimed to identify other potentially eligible trials or ancillary publications by searching the reference lists of retrieved included trials, as well as relevant systematic reviews, meta-analyses, and health technology assessment reports. We contacted experts in the field to ascertain additional relevant information. SELECTION CRITERIA: We included randomised controlled trials (RCTs) evaluating PICC design and materials. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methods. Our primary outcomes were venous thromboembolism (VTE), PICC-associated bloodstream infection (BSI), occlusion, and all-cause mortality. Secondary outcomes were catheter failure, PICC-related BSI, catheter breakage, PICC dwell time, and safety endpoints. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included 12 RCTs involving approximately 2913 participants (one multi-arm study). All studies except one had a high risk of bias in one or more risk of bias domain. Integrated valve technology compared to no valve technology for peripherally inserted central catheter design Integrated valve technology may make little or no difference to VTE risk when compared with PICCs with no valve (risk ratio (RR) 0.71, 95% confidence interval (CI) 0.19 to 2.63; I² = 0%; 3 studies; 437 participants; low certainty evidence). We are uncertain whether integrated valve technology reduces PICC-associated BSI risk, as the certainty of the evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Integrated valve technology may make little or no difference to occlusion risk when compared with PICCs with no valve (RR 0.86, 95% CI 0.53 to 1.38; I² = 0%; 5 studies; 900 participants; low certainty evidence). We are uncertain whether use of integrated valve technology reduces all-cause mortality risk, as the certainty of evidence is very low (RR 0.85, 95% CI 0.44 to 1.64; I² = 0%; 2 studies; 473 participants). Integrated valve technology may make little or no difference to catheter failure risk when compared with PICCs with no valve (RR 0.80, 95% CI 0.62 to 1.03; I² = 0%; 4 studies; 720 participants; low certainty evidence). We are uncertain whether integrated-valve technology reduces PICC-related BSI risk (RR 0.51, 95% CI 0.19 to 1.32; I² = not applicable; 2 studies (no events in 1 study); 542 participants) or catheter breakage, as the certainty of evidence is very low (RR 1.05, 95% CI 0.22 to 5.06; I² = 20%; 4 studies; 799 participants). Anti-thrombogenic surface modification compared to no anti-thrombogenic surface modification for peripherally inserted central catheter design We are uncertain whether use of anti-thrombogenic surface modified catheters reduces risk of VTE (RR 0.67, 95% CI 0.13 to 3.54; I² = 15%; 2 studies; 257 participants) or PICC-associated BSI, as the certainty of evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces occlusion (RR 0.69, 95% CI 0.04 to 11.22; I² = 70%; 2 studies; 257 participants) or all-cause mortality risk, as the certainty of evidence is very low (RR 0.49, 95% CI 0.05 to 5.26; I² = not applicable; 1 study; 111 participants). Use of anti-thrombogenic surface modified catheters may make little or no difference to risk of catheter failure (RR 0.76, 95% CI 0.37 to 1.54; I² = 46%; 2 studies; 257 participants; low certainty evidence). No PICC-related BSIs were reported in one study (111 participants). As such, we are uncertain whether use of anti-thrombogenic surface modified catheters reduces PICC-related BSI risk (RR not estimable; I² = not applicable; very low certainty evidence). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces the risk of catheter breakage, as the certainty of evidence is very low (RR 0.15, 95% CI 0.01 to 2.79; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Antimicrobial impregnation compared to non-antimicrobial impregnation for peripherally inserted central catheter design We are uncertain whether use of antimicrobial-impregnated catheters reduces VTE risk (RR 0.54, 95% CI 0.05 to 5.88; I² = not applicable; 1 study; 167 participants) or PICC-associated BSI risk, as the certainty of evidence is very low (RR 2.17, 95% CI 0.20 to 23.53; I² = not applicable; 1 study; 167 participants). Antimicrobial-impregnated catheters probably make little or no difference to occlusion risk (RR 1.00, 95% CI 0.57 to 1.74; I² = 0%; 2 studies; 1025 participants; moderate certainty evidence) or all-cause mortality (RR 1.12, 95% CI 0.71 to 1.75; I² = 0%; 2 studies; 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter failure (RR 1.04, 95% CI 0.82 to 1.30; I² = not applicable; 1 study; 221 participants; low certainty evidence). Antimicrobial-impregnated catheters probably make little or no difference to PICC-related BSI risk (RR 1.05, 95% CI 0.71 to 1.55; I² = not applicable; 2 studies (no events in 1 study); 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter breakage (RR 0.86, 95% CI 0.19 to 3.83; I² = not applicable; 1 study; 804 participants; low certainty evidence). AUTHORS' CONCLUSIONS: There is limited high-quality RCT evidence available to inform clinician decision-making for PICC materials and design. Limitations of the current evidence include small sample sizes, infrequent events, and risk of bias. There may be little to no difference in the risk of VTE, PICC-associated BSI, occlusion, or mortality across PICC materials and designs. Further rigorous RCTs are needed to reduce uncertainty.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Periférico , Desenho de Equipamento , Falha de Equipamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Tromboembolia Venosa , Humanos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Infecções Relacionadas a Cateter/prevenção & controle , Tromboembolia Venosa/prevenção & controle , Tromboembolia Venosa/etiologia , Obstrução do Cateter , Cateteres Venosos Centrais/efeitos adversos , Causas de Morte , Viés , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/instrumentação , Bacteriemia/prevenção & controle , Bacteriemia/etiologia
2.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38861398

RESUMO

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) offer potentially distinct advantages over transvenous defibrillator systems. Recent randomized trials showed significantly lower lead failure rates than transvenous ICD. Still, S-ICDs remain associated with the risk of inappropriate shocks (IAS). While previous studies have reported varying causes of IAS, this study explores a rare cause of IAS, referred to as 'sense-B-noise.' It was recently described in case series, but its incidence has not been studied in a large cohort of S-ICD patients. METHODS AND RESULTS: We retrospectively reviewed data from patients implanted with S-ICD models 1010, A209, and A219 between October 2009 and July 2023 across nine centres in Europe and the USA. The analysis concentrated on determining the incidence and understanding the implications of sense-B-noise events. Sense-B-noise represents a rare manifestation of distinct electrogram abnormalities within the primary and alternate sensing vectors. Data were collected from medical records, device telemetry, and manufacturer reports for investigation. This registry is registered on clinicaltrials.gov (NCT05713708). Subcutaneous implantable cardioverter-defibrillator devices of the 1158 patients were analysed. The median follow-up time for all patients was 46 (IQR 23-64) months. In 107 patients (9.2%) ≥1 IAS was observed during follow-up. Sense-B-noise failure was diagnosed in six (0.5 and 5.6% of all IAS) patients, in all patients, the diagnosis was made after an IAS episode. Median lead dwell time in the affected patients was 23 (2-70) months. To resolve the sense-B-noise defect, in three patients reprogramming to the secondary vector was undertaken, and two patients underwent system removal with subsequent S-ICD reimplantation due to low amplitude in the secondary vector. In one patient, the secondary vector was initially programmed, and subsequently, an S-ICD system exchange was performed due to T-wave-oversensing IAS episodes. CONCLUSION: This multicentre analysis' findings shed light on a rare but clinically highly significant adverse event in S-ICD therapy. To our knowledge, we provide the first systematic multicentre analysis investigating the incidence of sense-B-noise. Due to being difficult to diagnose and limited options for resolution, management of sense-B-noise is challenging. Complete system exchange may be the only option for some patients. Educating healthcare providers involved in S-ICD patient care is crucial for ensuring accurate diagnosis and effective management of sense-B-noise issues.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Sistema de Registros , Humanos , Masculino , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Incidência , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Idoso , Europa (Continente)/epidemiologia , Falha de Equipamento/estatística & dados numéricos , Estados Unidos/epidemiologia , Fatores de Risco
3.
Radiol Cardiothorac Imaging ; 6(3): e230303, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38869431

RESUMO

Purpose To examine the clinical effect of lead length and lead orientation in patients with cardiac implantable electronic devices (CIEDs) and lead fragments or abandoned leads undergoing 1.5-T MRI. Materials and Methods This Health Insurance Portability and Accountability Act-compliant retrospective study included patients with CIEDs and abandoned leads or lead fragments undergoing 1.5-T MRI from March 2014 through July 2020. CIED settings before and after MRI were reviewed, with clinically significant variations defined as a composite of the change in capture threshold of at least 50%, in sensing of at least 40%, or in lead impedance of at least 30% between before MRI and after MRI interrogation. Adverse clinical events were assessed at MRI and up to 30 days after. Univariable and multivariable analysis was performed. Results Eighty patients with 126 abandoned CIED leads or lead fragments underwent 107 1.5-T MRI examinations. Sixty-seven patients (median age, 74 years; IQR, 66-78 years; 44 male patients, 23 female patients) had abandoned leads, and 13 (median age, 66 years; IQR, 52-74 years; nine male patients, four female patients) had lead fragments. There were no reported deaths, clinically significant arrhythmias, or adverse clinical events within 30 days of MRI. Three patients with abandoned leads had a significant change in the composite of capture threshold, sensing, or lead impedance. In a multivariable generalized estimating equation analysis, lead orientation, lead length, MRI type, and MRI duration were not associated with a significant change in the composite outcome. Conclusion Use of 1.5-T MRI in patients with abandoned CIED leads or lead fragments of varying length and orientation was not associated with adverse clinical events. Keywords: Cardiac Assist Devices, MRI, Cardiac Implantable Electronic Device Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Marca-Passo Artificial/efeitos adversos , Pessoa de Meia-Idade , Falha de Equipamento/estatística & dados numéricos
4.
J Cardiothorac Surg ; 19(1): 306, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38822410

RESUMO

Peripheral venous catheter fracture with cardiovascular embolization is a rare but potentially serious complication. Herein, we report a case of peripheral venous catheter fracture with embolization in right ventricle in a preterm infant. The catheter fragment was successfully removed by surgical procedure via median sternotomy under cardiopulmonary bypass(CPB).We hope this case will increase awareness of this rare complication and improve cannulation safety.


Assuntos
Cateterismo Periférico , Remoção de Dispositivo , Recém-Nascido Prematuro , Humanos , Recém-Nascido , Cateterismo Periférico/métodos , Remoção de Dispositivo/métodos , Masculino , Falha de Equipamento , Ventrículos do Coração/cirurgia , Feminino
5.
Niger J Clin Pract ; 27(5): 678-681, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38842719

RESUMO

BACKGROUND: Tracheostomy is an important life-saving surgical procedure that could be used to secure the lower airway. It can however serve as a source of airway compromise when fragments from it are deposited. This condition must be diagnosed early enough, and appropriate intervention should be done to forestall potential morbidity and mortality. CASE REPORT: A 56-year-old tracheostomized patient presented to the accident and emergency department with a 4-hour history of sudden onset choking cough and labored breathing. The shaft of his tracheostomy tube (TT) was fractured and subsequently aspirated while he was attempting to remove and clean the inner tube that morning. He has used the TT for about 6 years and lost to follow-up clinic visits. The chest radiograph showed the metallic foreign body lodged within the trachea. He had an emergency rigid bronchoscopy via the tracheostomy stoma, and the object was retrieved. All respiratory symptoms subsequently resolved, and a check radiograph showed normal findings. CONCLUSION: Tracheostomy tube fracture and aspiration should be ruled out in every tracheostomized patient with sudden onset acute respiratory symptoms. Otolaryngologists must always emphasize the need for proper handling of TT, regular follow-up, and tube replacement when due.


Assuntos
Broncoscopia , Corpos Estranhos , Traqueostomia , Humanos , Corpos Estranhos/cirurgia , Corpos Estranhos/complicações , Masculino , Pessoa de Meia-Idade , Broncoscopia/métodos , Brônquios/lesões , Brônquios/diagnóstico por imagem , Falha de Equipamento , Obstrução das Vias Respiratórias/etiologia , Obstrução das Vias Respiratórias/cirurgia , Obstrução das Vias Respiratórias/diagnóstico
6.
Neurosurg Rev ; 47(1): 269, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38864925

RESUMO

Ventriculoperitoneal shunt surgery was developed to manage excessive cerebrospinal fluid (CSF) in the brain's ventricles and is considered a mainstream treatment. Despite the development of the shunt device system, various complications still occur. In this study, we reported 307 cases and a long-term follow-up of at least five years of adult patients who underwent VP shunt surgery and analyzed various factors that may affect revision surgery. A retrospective study was conducted at Asan Medical Center, Korea, a tertiary medical center. We reviewed 307 cases from January 2012 to December 2018. The patients' neurological status, predisposing medical conditions, laboratory findings, and other operation-related factors were reviewed using electrical medical records. The normal function group comprised 272 cases (88.6%), and the overall incidence of revision group comprised 35 cases (11.4%). Of the 35 revision surgery cases, 30 (85.71%) were due to shunt malfunctions, such as obstruction, overdrainage, and valve-related errors while 5 (14.29%) were due to shunt infection. Patient demographics, mental status, and operation time did not influence revision as risk factors. Serum laboratory findings showed no statistical difference between the two groups. The white blood cell (WBC) count in the CSF profile differed significantly between the two groups. The Hakim Programmable valve (Codman, USA) is mainly used in our center. In addition, various shunt systems were used, including Strata Regulatory valve (Medtronic, USA), proGAV (Aesculap, USA), and Accu-Flo (Codman, USA). This study analyzed the factors affecting long-term outcomes. Based on these findings, efforts are needed to achieve more favorable outcomes in the future.


Assuntos
Hidrocefalia , Derivação Ventriculoperitoneal , Humanos , Derivação Ventriculoperitoneal/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Fatores de Risco , Adulto , Estudos Retrospectivos , Incidência , Idoso , Seguimentos , Hidrocefalia/cirurgia , Reoperação , Complicações Pós-Operatórias/epidemiologia , Falha de Equipamento , Adulto Jovem
7.
Ren Fail ; 46(2): 2369695, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38938162

RESUMO

BACKGROUND: This study aims to establish a simplified and effective animal model of catheter malfunction caused by omental wrapped using negative pressure suction. METHOD: The peritoneal dialysis catheter outlet was linked to a negative-pressure (0-75mmHg) suction pump to intensify the negative pressure. Different negative pressures were tested for model construction in vitro. In vivo, a model of peritoneal catheter malfunction caused by omental wrapped was constructed in five beagles after catheter placement. Catheter drainage conditions and related complications were monitored before and after the model establishment. RESULTS: In the vitro experiment, the overall success rate of constructed models was 90% (36/40). The total malfunction rate was higher in 62.5 mmHg (10/10) and 75 mmHg (10/10) than in 12.5 mmHg (8/10) and 37.5 mmHg (8/10). The outflow velocity of dialysate at 62.5 mmHg was significantly lower than that at 12.5 mmHg and 37.5 mmHg, without a statistically significant difference compared to 75 mmHg. In the in vivo experiment, catheter outflow velocity increased, and residual fluid volume decreased after omental wrapped (99.6 ± 6.7 ml/min vs. 32.6 ± 4.6 ml/min at initial five minutes, p < 0.0001; 69.2 ± 16.3 ml vs. 581.0 ± 109.4 ml, p < 0.001). And the outflow velocity was finally below 2 ml/min. No severe related complications (such as infection, organ damage, or bleeding) were observed through laparoscopic examination and dialysate tests seven days post-operation. CONCLUSION: Utilizing negative pressure suction to increase negative pressure around catheter tip is a simple, safe, and effective method for establishing an animal model of omental wrapped leading to catheter malfunction.


Assuntos
Falha de Equipamento , Omento , Diálise Peritoneal , Animais , Cães , Sucção/instrumentação , Diálise Peritoneal/instrumentação , Diálise Peritoneal/efeitos adversos , Cateteres de Demora/efeitos adversos , Modelos Animais de Doenças , Masculino , Modelos Animais
8.
Neurosurg Focus ; 56(6): E12, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38823042

RESUMO

OBJECTIVE: The aim of this study was 1) to describe the rate of intrathecal baclofen (ITB)-associated complications at a large tertiary center, and 2) to evaluate the impact of patient-related factors on the likelihood of developing such complications. METHODS: A retrospective single-center study was carried out. A total of 301 eligible patients were included in the analysis. Univariate regression models were used to evaluate the impact of age, sex, diagnosis, ambulation status, modified Ashworth scale score, body mass index, diabetes status, and pain level on the likelihood of developing a device-related infection, pump malfunction, catheter malfunction, and other clinically significant complications. RESULTS: Overall, 27% of patients experienced an ITB-related complication. The most common complications included infection (6%, 18/301), pump malfunction (7.3%, 22/301), and catheter malfunction (14%, 42/301). The univariate analyses revealed that the patient's ambulatory status had a significant impact on the likelihood of developing a catheter-related malfunction. Furthermore, a trend toward significance was identified between patients' preoperative body mass index and device-related infection. Finally, the risk of suffering any ITB-related complications was statistically correlated with the number of years that had passed since the initial pump implantation. CONCLUSIONS: The authors' analysis reveals a previously underrecognized association between ambulatory status at the time of ITB pump implantation and the incidence of catheter-related complications, and confirms the impact of time since surgery on the risk of developing any ITB-related complication. The patient's age, sex, diagnosis, diabetes status, or pain level at baseline were not associated with the risk of complications. Collectively, these insights contribute novel information to the existing literature, providing practical value for physicians in guiding patient selection for ITB therapy.


Assuntos
Baclofeno , Bombas de Infusão Implantáveis , Injeções Espinhais , Relaxantes Musculares Centrais , Humanos , Baclofeno/administração & dosagem , Baclofeno/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto , Fatores de Risco , Bombas de Infusão Implantáveis/efeitos adversos , Relaxantes Musculares Centrais/administração & dosagem , Relaxantes Musculares Centrais/efeitos adversos , Injeções Espinhais/efeitos adversos , Idoso , Adulto Jovem , Espasticidade Muscular/tratamento farmacológico , Falha de Equipamento/estatística & dados numéricos , Adolescente
9.
Neurosurg Focus ; 56(6): E11, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38823047

RESUMO

OBJECTIVE: Intrathecal baclofen (ITB) pumps are commonly used in pediatric patients with cerebral palsy (CP) and medically refractory spasticity. However, catheter malfunction and associated risk factors are not well understood. The aim of this study was to examine potential risk factors for spinal catheter malfunction and characterize postoperative follow-up to understand the clinical consequences. METHODS: Patients who received ITB pump replacement or revision at Boston Children's Hospital between 2010 and 2023 were retrospectively reviewed. The spinal catheter revision cohort (SCRC) included patients whose spinal catheter was occluded requiring lumbar catheter revision. The second cohort included abdominal pump replacements only (APRC). Between-group comparisons and multivariable regression identified factors associated with catheter revision and postoperative outcomes. RESULTS: Forty-one (33.6%) patients underwent spinal catheter revision and were compared with 81 patients (66.4%) who underwent abdominal pump replacement only. Younger age at surgery and an elevated preoperative lower-extremity modified Ashworth scale grade were associated with spinal catheter revision (p < 0.05). Catheter model type, tip location, and history of spinal fusion were not associated with obstruction. Postoperatively, SCRC patients experienced a higher rate of infection (17.1%) relative to APRC patients (0%) within 30 days from their ITB pump replacement procedure (p < 0.05) and greater likelihood of subsequent ITB system removal compared with the APRC (24.4% vs 7.4%, p < 0.05). Although not differing preoperatively, SCRC patients had lower postoperative ITB doses when compared with the APRC group (median dose 143 vs 350 µg/day, p < 0.05) at hospital discharge and remained statistically different at the 6-month and 1-year follow-ups (p < 0.05). There were no postoperative differences in baclofen overdose, withdrawal, or median number of hospital readmissions within 30 days. Overall, 31.7% of spinal catheter revisions were unanticipated by the clinical team at time of surgery. CONCLUSIONS: Younger age at surgery and increased preoperative lower-extremity tone may be risk factors for catheter obstruction, resulting in a higher rate of postoperative infection and subsequent ITB pump removal compared with pump replacement alone. Spinal catheter occlusion can complicate revision or replacement procedures, especially when unanticipated. Routine clinical assessment may be inadequate for diagnosing insidious catheter malfunction. Catheter occlusion deserves further study, and routine assessment of catheter patency may be warranted to prevent suboptimal tone therapy.


Assuntos
Baclofeno , Paralisia Cerebral , Bombas de Infusão Implantáveis , Relaxantes Musculares Centrais , Humanos , Baclofeno/administração & dosagem , Baclofeno/efeitos adversos , Masculino , Feminino , Criança , Bombas de Infusão Implantáveis/efeitos adversos , Fatores de Risco , Relaxantes Musculares Centrais/administração & dosagem , Estudos Retrospectivos , Adolescente , Paralisia Cerebral/cirurgia , Paralisia Cerebral/complicações , Pré-Escolar , Espasticidade Muscular/tratamento farmacológico , Espasticidade Muscular/etiologia , Espasticidade Muscular/cirurgia , Reoperação/métodos , Injeções Espinhais/métodos , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Falha de Equipamento , Estudos de Coortes
11.
Forensic Sci Int ; 359: 112001, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38714107

RESUMO

BACKGROUND: Cardiac implantable electronic devices (CIED) are a heterogeneous group of medical devices with increasingly sophisticated diagnostic capabilities, which could be exploited in forensic investigations. However, current guidelines are lacking clear recommendations on the topic. The first aim of this systematic review is to provide an updated assessment of the role of postmortem CIED interrogation, and to give practical recommendations, which can be used in daily practice. Secondly, the authors aim to determine the rates of postmortem CIED interrogation and autopsy investigations, the type of final rhythm detected close to death (with a focus on the significance of documented arrhythmias), as well as the role of postmortem CIED interrogation in the determination of final cause/time of death, and any potentially fatal device malfunctions. METHODS: A systematic search in MEDLINE and Scopus aiming to identify reports concerning postmortem human CIED interrogation was performed, including a systematic screening of reference lists. Case reports, letters to the editors, commentaries, review articles or guidelines were excluded, along with studies related to cardiac devices other than CIED. All data were pooled and analyzed using fixed-effects meta-analysis models, and the I2 statistic was used to assess heterogeneity. RESULTS: A total of 25 articles were included in the systematic review, enrolling 3194 decedent CIED carriers. Ten studies (40%) had a 100% autopsy rate, whereas in further 6 studies autopsy findings were variably reported; CIED interrogation was available from 22 studies (88%), and it was never performed prior to autopsy. The overall rate of successful postmortem CIED interrogation was 89%, with high heterogeneity among studies, mainly due to device deactivation/battery discharge. Twenty-four percent of CIED carriers experienced sudden cardiac death (SCD), whereas non-sudden cardiac and non-cardiac death (NSCD, NCD) were reported in 37% and 30% of decedents, respectively. Ventricular tachyarrhythmias were recorded in 34% of overall successfully interrogated CIED, and in 62% of decedents who experienced a SCD; of all ventricular tachyarrhythmias recorded, 40% was found in NSCD or NCD. A clear interpretation of the etiological role of recorded arrhythmias in the causation of death required integration with autopsy findings. Overall, potentially fatal device malfunctions were detected in 12% of cases. CONCLUSIONS: Postmortem CIED interrogation is a valuable tool for the determination of the cause of death, and may complement autopsy. Forensic pathologists need to know the potential utility, pitfalls, and limitations of this diagnostic examination to make this tool as much reliable as possible.


Assuntos
Causas de Morte , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Arritmias Cardíacas , Falha de Equipamento , Marca-Passo Artificial/efeitos adversos , Guias como Assunto , Autopsia
12.
PLoS One ; 19(5): e0303152, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38722995

RESUMO

INTRODUCTION: Short peripheral intravenous catheter (PIVC) failure is a common complication that is generally underdiagnosed. Some studies have evaluated the factors associated with these complications, but the impact of care complexity individual factors and nurse staffing levels on PIVC failure is still to be assessed. The aim of this study was to determine the incidence and risk factors of PIVC failure in the public hospital system of the Southern Barcelona Metropolitan Area. METHODS: A retrospective multicentre observational cohort study of hospitalised adult patients was conducted in two public hospitals in Barcelona from 1st January 2016 to 31st December 2017. All adult patients admitted to the hospitalisation ward were included until the day of discharge. Patients were classified according to presence or absence of PIVC failure. The main outcomes were nurse staffing coverage (ATIC patient classification system) and 27-care complexity individual factors. Data were obtained from electronic health records in 2022. RESULTS: Of the 44,661 patients with a PIVC, catheter failure was recorded in 2,624 (5.9%) patients (2,577 [5.8%] phlebitis and 55 [0.1%] extravasation). PIVC failure was more frequent in female patients (42%), admitted to medical wards, unscheduled admissions, longer catheter dwell time (median 7.3 vs 2.2 days) and those with lower levels of nurse staffing coverage (mean 60.2 vs 71.5). Multivariate logistic regression analysis revealed that the female gender, medical ward admission, catheter dwell time, haemodynamic instability, uncontrolled pain, communication disorders, a high risk of haemorrhage, mental impairments, and a lack of caregiver support were independent factors associated with PIVC failure. Moreover, higher nurse staffing were a protective factor against PIVC failure (AUC, 0.73; 95% confidence interval [CI]: 0.72-0.74). CONCLUSION: About 6% of patients presented PIVC failure during hospitalisation. Several complexity factors were associated with PIVC failure and lower nurse staffing levels were identified in patients with PIVC failure. Institutions should consider that prior identification of care complexity individual factors and nurse staffing coverage could be associated with a reduced risk of PIVC failure.


Assuntos
Cateterismo Periférico , Humanos , Feminino , Masculino , Estudos Retrospectivos , Cateterismo Periférico/efeitos adversos , Pessoa de Meia-Idade , Idoso , Fatores de Risco , Adulto , Admissão e Escalonamento de Pessoal , Falha de Equipamento/estatística & dados numéricos , Recursos Humanos de Enfermagem Hospitalar/estatística & dados numéricos , Hospitalização/estatística & dados numéricos , Espanha/epidemiologia
13.
Card Electrophysiol Clin ; 16(2): 163-168, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749636

RESUMO

A 69-year-old woman with a history of heart failure with reduced ejection fraction presented for device interrogation of her cardiac implantable electronic device (CIED), revealing lead and pulse generator displacement. Surprisingly, she exhibited a narrow QRS on the ECG despite an underlying right bundle branch block, suggesting unintentional conduction system pacing (CSP). Traditional cardiac resynchronization therapy has been widely used for patients with heart failure, but alternatives like CSP are emerging as viable options. Given the global rise in CIED utilization, regular follow-up, device troubleshooting, and embracing remote monitoring are essential to manage and optimize patient outcomes.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Idoso , Feminino , Humanos , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Eletrocardiografia , Falha de Equipamento , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia
14.
Neurol Sci ; 45(7): 3495-3501, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38714597

RESUMO

BACKGROUND: Shunt obstruction is a type of ventriculoperitoneal shunt (VPS) failure. Whether changes in cerebrospinal fluid (CSF) parameters can influence shunt outcomes or not is debatable. METHODS: In this study, we retrospectively included adult hydrocephalus patients who received VPS from 6 general hospitals in different provinces of China from November 2013 to September 2021. The inclusion criteria: Patients with hydrocephalus of all etiologies underwent shunt surgery from 6 general hospitals in different provinces of China were included in the study. The exclusion criteria: 1.Patients under the age of 18; 2.Patients who had previous shunt surgery; 3. Shunt failure from other factors; 4.Patients died from other causes; 5. Patients with incomplete data. The CSF of shunt patients had been analyzed at the time of shunt insertion. The CSF samples were collected and analyzed when the shunt was implanted. The relationship between CSF parameters and the incidence rate of shunt obstruction in one year was analyzed. RESULTS: A total of 717 eligible patients from 6 hospitals were included, of whom 59(8.23%) experienced obstruction. Multivariate logistic regression analysis identified that protein level(odds ratio [OR] 1.161, 95% CI 1.005 ~ 1.341, p = 0.043), decreased glucose level(< 2.5 mmol/L)(odds ratio 3.784, 95% confidence interval 1.872 ~ 7.652, p = 0.001) and protein level increase(> 0.45 g/L) (odds ratio 3.653, 95% confidence interval 1.931 ~ 6.910, p = 0.001)were independent risk factors of shunt obstruction. CONCLUSION: This study suggested that increased protein level (> 0.45 g/L) and decreased glucose level (< 2.5 mmol/L) in CSF indicated an increased risk of shunt obstruction in a patient with hydrocephalus. Thus, shunt surgery should be more carefully considered when the CSF glucose and protein were abnormal.


Assuntos
Hidrocefalia , Derivação Ventriculoperitoneal , Humanos , Derivação Ventriculoperitoneal/efeitos adversos , Feminino , Masculino , Hidrocefalia/cirurgia , Hidrocefalia/líquido cefalorraquidiano , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , China/epidemiologia , Adulto , Falha de Equipamento
15.
BMJ Open ; 14(5): e081749, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760049

RESUMO

OBJECTIVES: To compare catheter-related outcomes of individuals who received a tunnelled femorally inserted central catheter (tFICC) with those who received a peripherally inserted central catheter (PICC) in the upper extremities. DESIGN: A propensity-score matched cohort study. SETTING: A 980-bed tertiary referral hospital in South West Sydney, Australia. PARTICIPANTS: In-patients referred to the hospital central venous access service for the insertion of a central venous access device. PRIMARY AND SECONDARY OUTCOME MEASURES: The primary outcome of interest was the incidence of all-cause catheter failure. Secondary outcomes included the rates of catheters removed because of suspected or confirmed catheter-associated infection, catheter dwell and confirmed upper or lower extremity deep vein thrombosis (DVT). RESULTS: The overall rate of all-cause catheter failure in the matched tFICC and PICC cohort was 2.4/1000 catheter days (95% CI 1.1 to 4.4) and 3.0/1000 catheter days (95% CI 2.3 to 3.9), respectively, and when compared, no difference was observed (difference -0.63/1000 catheter days, 95% CI -2.32 to 1.06). We found no differences in catheter dwell (mean difference of 14.2 days, 95% CI -6.6 to 35.0, p=0.910); or in the cumulative probability of failure between the two groups within the first month of dwell (p=0.358). No significant differences were observed in the rate of catheters requiring removal for confirmed central line-associated bloodstream infection (difference 0.13/1000 catheter day, 95% CI -0.36 to 0.63, p=0.896). Similarly, no significant differences were found between the groups for confirmed catheter-related DVT (difference -0.11 per 1000 catheter days, 95% CI -0.26 to 0.04, p=1.00). CONCLUSION: There were no differences in catheter-related outcomes between the matched cohort of tFICC and PICC patients, suggesting that tFICCs are a possible alternative for vascular access when the veins of the upper extremities or thoracic region are not viable for catheterisation.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateterismo Periférico , Pontuação de Propensão , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/etiologia , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/métodos , Cateterismo Periférico/efeitos adversos , Idoso , Cateteres Venosos Centrais/efeitos adversos , Estudos de Coortes , Austrália/epidemiologia , Adulto , Cateteres de Demora/efeitos adversos , Remoção de Dispositivo/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos
17.
PeerJ ; 12: e17418, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38799069

RESUMO

Aim: Assess the effect of simulated clinical use and sterilization on the cyclic fatigue resistance of Race Evo and Tia Tornado Blue nickel titanium (NiTi) files. Materials and Methods: For this study, a total of sixty-four NiTi files were selected, with thirty-two files each from two different manufacturers. Files from each manufacturer were subdivided into four subgroups (n = 8) based on the test parameters. The control groups included files that were neither used nor sterilized. Files from the test groups were used to prepare the root canals of extracted mandibular premolars and then sterilized. This procedure was repeated once, twice, or thrice, depending on the test group. All files were then subjected to a cyclic fatigue test. Data was statistically analyzed using the Kruskal-Wallis and Mann-Whitney U tests. Results: No significant difference was observed in the number of cycles to failure (NCF) among the subgroups for both types of files (P = 0.869 for Tia Tornado Blue, P = 0.626 for Race Evo). Tia Tornado Blue files displayed significantly higher NCF values in the control (P = 0.021), once (P = 0.027), and thrice (P = 0.031) usage groups when compared to Race Evo files. Conclusions: Repeated clinical use and sterilization for up to three cycles did not affect the cyclic fatigue resistance of Race Evo and Tia Tornado Blue files.


Assuntos
Níquel , Esterilização , Titânio , Esterilização/métodos , Humanos , Falha de Equipamento , Teste de Materiais , Preparo de Canal Radicular/instrumentação
18.
Cochrane Database Syst Rev ; 5: CD013023, 2024 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780138

RESUMO

BACKGROUND: Peripheral arterial catheters (ACs) are used in anaesthesia and intensive care settings for blood sampling and monitoring. Despite their importance, ACs often fail, requiring reinsertion. Dressings and securement devices maintain AC function and prevent complications such as infection. OBJECTIVES: To evaluate the effectiveness of peripheral AC dressing and securement devices to prevent failure and complications in hospitalised people. SEARCH METHODS: We searched the Cochrane Wounds Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL Plus up to 16 May 2023. We also searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform up to 16 May 2023. SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing different dressing and securement devices for the stabilisation of ACs in hospitalised people. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials for inclusion, extracted data, and assessed risk of bias using Cochrane's RoB 1 tool. We resolved disagreements by discussion, or by consulting a third review author when necessary. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included five RCTs with 1228 participants and 1228 ACs. All included studies had high risk of bias in one or more domains. We present the following four comparisons, with the remaining comparisons reported in the main review. Standard polyurethane (SPU) plus tissue adhesive (TA) compared with SPU: we are very uncertain whether use of SPU plus TA impacts rates of AC failure (risk ratio (RR) 0.44, 95% confidence interval (CI) 0.20 to 0.98; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Neither study (165 participants) reported catheter-related bloodstream infections (CRBSI), thus we are very uncertain whether SPU plus TA impacts on the incidence of CRBSI (very low-certainty evidence). It is very uncertain whether use of SPU plus TA impacts AC dislodgement risk (RR 0.54, 95% CI 0.03 to 9.62; I² = 44%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts AC occlusion rates (RR 1.20, 95% CI 0.37 to 3.91; I² = 3%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts rates of adverse events with few reported events across groups (RR 0.89, 95% CI 0.09 to 8.33; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Bordered polyurethane (BPU) compared to SPU: we are very uncertain whether use of BPU impacts rates of AC failure (RR 0.67, 95% CI 0.21 to 2.13; 1 study, 60 participants; very low-certainty evidence). BPU may make little or no difference to CRBSI compared to SPU (RR 3.05, 95% CI 0.12 to 74.45; I² = not applicable as 1 study (60 participants) reported 0 events; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to the risk of AC dislodgement compared with SPU (RR 0.75, 95% CI 0.17 to 3.22; I² = 0%; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to occlusion risk compared with SPU (RR 0.80, 95% CI 0.60 to 1.07; I² = 0%; 2 studies, 572 participants; low-certainty evidence). It is very uncertain whether BPU impacts on the risk of adverse events compared with SPU (RR 0.33, 95% CI 0.01 to 7.87; 1 study, 60 participants; very low-certainty evidence). SPU plus sutureless securement devices (SSD) compared to SPU: we are very uncertain whether SPU plus SSD impacts risk of AC failure compared with SPU (RR 0.78, 95% CI 0.40 to 1.52; I² = 0%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain if SPU plus SSD impacts CRBSI incidence rate with no events in both groups (2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of dislodgement (RR 0.14, 95% CI 0.01 to 2.57; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of AC occlusion (RR 1.94, 95% CI 0.50 to 7.48; I² = 38%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain whether SPU plus SSD impacts on the risk of adverse events (RR 1.94, 95% CI 0.19 to 20.24; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). Integrated securement dressings compared to SPU: integrated securement dressings may result in little or no difference in risk of AC failure compared with SPU (RR 1.96, 95% CI 0.80 to 4.84; 1 study, 105 participants; low-certainty evidence); may result in little or no difference in CRBSI incidence with no events reported (1 study, 105 participants; low-certainty evidence); may result in little or no difference in the risk of dislodgement (RR 0.33, 95% CI 0.04 to 3.04; 1 study, 105 participants; low-certainty evidence), may result in little or no difference in occlusion rates with no events reported (1 study, 105 participants; low-certainty evidence), and may result in little or no difference in the risk of adverse events (RR 0.35, 95% CI 0.01 to 8.45; 1 study, 105 participants; low-certainty evidence). AUTHORS' CONCLUSIONS: There is currently limited rigorous RCT evidence available about the relative clinical effectiveness of AC dressing and securement products. Limitations of current evidence include small sample size, infrequent events, and heterogeneous outcome measurements. We found no clear difference in the incidence of AC failure, CRBSI, or adverse events across AC dressing or securement products including SPU, BPU, SSD, TA, and integrated securement products. The limitations of current evidence means further rigorous RCTs are needed to reduce uncertainty around the use of dressing and securement devices for ACs.


Assuntos
Bandagens , Infecções Relacionadas a Cateter , Cateterismo Periférico , Poliuretanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Infecções Relacionadas a Cateter/prevenção & controle , Viés , Falha de Equipamento
19.
BMC Oral Health ; 24(1): 585, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773530

RESUMO

Periodontal instrument fractures are rare events in dentistry, with limited literature available on their occurrence and management. This case report highlights an incident involving the fracture of a periodontal sickle scaler blade during manual instrumentation for the removal of calculus. The fracture occurred during instrumentation on the mesial surface of the maxillary right second molar, and the separated blade was subsequently pushed into the sulcus. A radiographic assessment was performed to verify the precise location of the fractured segment. Following confirmation, the broken blade was subsequently retrieved using curved artery forceps. The case report highlights factors contributing to instrument fractures, emphasizing the importance of instrument maintenance, sterilization cycles, and operator technique. Ethical considerations regarding patient disclosure, informed consent, and instrument retrieval methods are well discussed. This case underscores the importance of truthful communication, the proper use of instruments, equipment maintenance in dentistry, and the significance of ongoing professional development to enhance treatment safety, proficiency, and ethical standards in dental care.


Assuntos
Falha de Equipamento , Humanos , Masculino , Instrumentos Odontológicos/efeitos adversos , Raspagem Dentária , Ética Odontológica , Pessoa de Meia-Idade
20.
World Neurosurg ; 186: e432-e439, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38561030

RESUMO

OBJECTIVE: Spinal cord stimulators (SCSs) are commonly implanted via a laminotomy or laminectomy. Revision surgery may be necessary in instances of hardware failure or loss of efficacy. It is uncommon for leads to have been initially misplaced in a suboptimal position and revision in these cases necessitates additional dissection for appropriate repositioning. Accordingly, there is concern with a more extensive revision for a potentially higher risk of associated complications. This study aims to describe a series of patients with failed paddle SCS electrodes due to misplacement who underwent revision and replacement. METHODS: Patients who underwent SCS paddle replacement for misplaced paddles between 2021 and 2023 were identified. Medical charts were reviewed for demographic data, operative details, and incidence of complications. RESULTS: Sixteen patients underwent thoracic SCS paddle revision and replacement. The mean age was 59.6 ± 12.6 years, with 11 females and 5 males. Misplaced paddles were too lateral (n = 12), too high (n = 2), or incompletely within the epidural space (n = 2). The mean duration from initial implantation to revision surgery was 44.8 ± 47.5 months. The mean operative duration was 126.1 ± 26.9 minutes and all patients required a "skip" laminectomy or laminotomy. No complications were encountered. The mean length of follow-up was 18.4 ± 7.3 months. Mean preoperative pain intensity was 7.9 ± 1.5 and at last follow-up was 3.6 ± 1.7 (P < 0.001). All but 1 patient continued to use their device in follow-up. CONCLUSIONS: The revision and replacement of misplaced paddle SCS electrodes is a feasible and durable revision strategy, even in long-term implants with extensive scarring.


Assuntos
Eletrodos Implantados , Falha de Equipamento , Laminectomia , Reoperação , Estimulação da Medula Espinal , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estimulação da Medula Espinal/instrumentação , Estimulação da Medula Espinal/métodos , Eletrodos Implantados/efeitos adversos , Idoso , Estudos Retrospectivos , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA