Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.897
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 368, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730497

RESUMO

BACKGROUND: This systemic review and meta-analysis aimed to evaluate the clinical outcomes of proximal humeral fracture in elderly patient fixation using locked plate with or without cement augmentation. METHODS: The databases of PubMed, Embase, and Cochrane Library were searched in August 2023 for literature comparing the clinical outcomes of patients with PHFs treated with locked plate alone and locked plate augmented with cement. Data describing study design; level of evidence; inclusion criteria; demographic information; final follow-up; revision rate; implant failure rate; avascular necrosis rate; total complication rate; constant score; and disability of arm, shoulder, and hand (DASH) score were collected. RESULTS: Eight studies (one randomized-controlled trial and seven observational studies), involving 664 patients, were identified. Compared with locked plates alone, using cement-augmented locked plates reduced the implant failure rate (odds ratio (OR) = 0.19; 95% confidence interval (CI) 0.10-0.39; P < 0.0001) and total complication rate (OR = 0.45; 95% CI 0.29-0.69; P = 0.0002) and improved DASH scores (mean difference (MD) = 2.99; 95% CI 1.00-4.98; P = 0.003). However, there was no significant difference in clinical outcomes, including revision rate, avascular necrosis rate, and constant score. CONCLUSION: In this review and meta-analysis, fixation of the PHFs in elderly patients using locked plates with or without cement augmentation has no significant difference in revision rate, but the implant failure and total complication rates may be lesser on using the cement-augmented locked plate for fixation than on using a locked plate alone. Good results are expected for most patients treated with this technique. TRIAL REGISTRATION: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)21 guidelines were followed to conduct this systematic review and meta-analysis and was registered as a protocol in PROSPERO (CRD42022318798).


Assuntos
Cimentos Ósseos , Placas Ósseas , Fixação Interna de Fraturas , Fraturas do Ombro , Humanos , Fraturas do Ombro/cirurgia , Fraturas do Ombro/diagnóstico por imagem , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/efeitos adversos , Cimentos Ósseos/uso terapêutico , Cimentos Ósseos/efeitos adversos , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Reoperação
2.
Dan Med J ; 71(5)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38704836

RESUMO

INTRODUCTION: Following surgical management of patella fractures, patients commonly report pain; difficulties with weight-bearing tasks such as walking, running and climbing stairs; and restrictions in quality of life. Recently, a locking plate system for surgical management of patella fractures has been introduced. To date, no studies have compared standard treatment with tension band wiring with locking plate fixation in a randomised study design. We aim to compare the one-year patient-reported Knee Injury and Osteoarthritis Outcome subscale scores (KOOS5-subscales) after standard care tension band fixation with locking plate fixation for patients with patella fractures. METHODS: This is a multicentre randomised and prospective clinical trial. A total of 122 patients will be included in the study, and the primary outcome will be the KOOS subscales at 12 months after surgery. CONCLUSIONS: Findings from the present study are expected to advance our understanding of outcome following surgical treatment of patella fractures. FUNDING: This study is funded, in part, by the Novo Nordisk Foundation, Denmark. CLINICALTRIALS: gov ID: NCT04891549.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas Ósseas , Patela , Humanos , Patela/lesões , Patela/cirurgia , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Estudos Prospectivos , Feminino , Masculino , Resultado do Tratamento , Fios Ortopédicos , Adulto , Ensaios Clínicos Controlados Aleatórios como Assunto , Pessoa de Meia-Idade , Dinamarca , Qualidade de Vida , Fratura da Patela
3.
Trials ; 25(1): 305, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38711052

RESUMO

BACKGROUND: To analyze the perioperative bleeding and hidden blood loss (HBL) of sacroiliac screw minimally invasive treatment of pelvic posterior ring injury and explore the influential factors of HBL after operation for providing reference for clinical treatment. METHOD: A retrospective analysis was conducted on data from 369 patients with posterior pelvic ring injuries treated with sacroiliac screws internal fixation at our hospital from January 2015 to January 2022. The research was registered in the Chinese Clinical Trial Registry in July 2022 (ChiCTR2200061866). The total blood loss (TBL) and HBL of patients were counted, and the factors such as gender, age, and surgical duration were statistically analyzed. The influential factors of HBL were analyzed by multiple linear regression. RESULTS: The TBL was 417.96 ± 98.05 ml, of which the visible blood loss (VBL) was 37.00 ± 9.0 ml and the HBL was 380.96 ± 68.8 ml. The HBL accounted for 91.14 ± 7.36% of the TBL. Gender, surgical duration, fixed position, and fixed depth had significant effects on the HBL (P < 0.05). CONCLUSIONS: The HBL was the main cause of anemia after minimally invasive treatment of posterior pelvic ring injury with a sacroiliac screw. Gender, surgical duration, fixed position, and fixed depth were closely related to the occurrence of HBL. In clinical treatment, we should consider these influential factors and take effective measures to reduce the impact of HBL on patients.


Assuntos
Perda Sanguínea Cirúrgica , Parafusos Ósseos , Fixação Interna de Fraturas , Ossos Pélvicos , Humanos , Masculino , Feminino , Estudos Retrospectivos , Ossos Pélvicos/lesões , Ossos Pélvicos/cirurgia , Adulto , Pessoa de Meia-Idade , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Fatores de Risco , Adulto Jovem , Fraturas Ósseas/cirurgia , Fraturas Ósseas/diagnóstico por imagem , Fatores de Tempo , China , Idoso , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Anemia/etiologia
4.
J Plast Surg Hand Surg ; 59: 46-52, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747532

RESUMO

Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results. Five female patients aged 63-74 with dorsally angulated extra-articular malunions underwent surgery using 3D-printed guides and the shim instrument. The plate position, drilling guide alignment, screw placements, and distal radius correction on postoperative CTs were compared with the surgical plans. Errors were measured using an anatomical coordinate system, and standard 2D radiographic measures were extracted. Preoperative dorsal tilt ranged from 16° to 35°, and postoperative volar tilt from 1° to 11°. 3D analysis revealed mean absolute correction errors of 6.1° in volar tilt, 1.6° in radial inclination, and 0.6 mm in ulnar variance. The volar tilt error due to the shim instrument, indicated by the mean angle error of the distal screws to the plate, was 2.1° but varied across the five patients. Settling of the distal radius, due to tension during and after reduction, further contributed to a mean loss of 3.5° in volar tilt. The shim instrument helped with securing plates at the intended angle; however, further correction improvements should consider the tension between the fragments of osteoporotic bone.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas Mal-Unidas , Osteotomia , Fraturas do Rádio , Humanos , Feminino , Osteotomia/métodos , Osteotomia/instrumentação , Pessoa de Meia-Idade , Fraturas do Rádio/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Idoso , Fraturas Mal-Unidas/cirurgia , Fraturas Mal-Unidas/diagnóstico por imagem , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Impressão Tridimensional , Cirurgia Assistida por Computador , Imageamento Tridimensional , Parafusos Ósseos , Tomografia Computadorizada por Raios X
5.
Jt Dis Relat Surg ; 35(2): 439-442, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38727126

RESUMO

Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.


Assuntos
Fios Ortopédicos , Migração de Corpo Estranho , Olécrano , Osteotomia , Humanos , Fios Ortopédicos/efeitos adversos , Masculino , Pessoa de Meia-Idade , Olécrano/lesões , Olécrano/cirurgia , Olécrano/diagnóstico por imagem , Osteotomia/efeitos adversos , Osteotomia/métodos , Osteotomia/instrumentação , Migração de Corpo Estranho/cirurgia , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Fraturas do Úmero/cirurgia , Fraturas do Úmero/diagnóstico por imagem , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Remoção de Dispositivo/métodos , Articulação do Cotovelo/cirurgia , Articulação do Cotovelo/diagnóstico por imagem , Fraturas Intra-Articulares/cirurgia , Fraturas Intra-Articulares/diagnóstico por imagem
6.
BMC Musculoskelet Disord ; 25(1): 343, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38693479

RESUMO

PURPOSE: To explore whether it is necessary to put drain tubes after posterior pedicle screw fixation of thoracolumbar fractures. METHODS: From April 2020 to January 2023, a total of 291 patients with recent thoracolumbar fractures (AO type-A or type-B) who received the pedicle screw fixation operation were enrolled retrospectively. In 77 patients, drain tubes were used in the pedicle screw fixation surgery, while no drain tubes were placed in the other group. After gleaning demographic information and results of lab examination and imageology examination, all data were put into a database. Independent-sample t-tests, Pearson Chi-Square tests, Linear regression analysis, and correlation analysis were then performed. RESULTS: Compared to the control group, the drainage group had significantly lower postoperative CRP levels (P = 0.047), less use of antipyretics (P = 0.035), higher ADL scores (P = 0.001), and lower NRS scores (P < 0.001) on the 6th day after surgery. Other investigation items, such as demographic information, operation time, intraoperative blood loss, body temperature, and other preoperative and postoperative lab results, showed no significant differences. CONCLUSIONS: The use of a drain tube in the pedicle screw fixation of thoracolumbar fractures is correlated with the improvement of patients' living and activity ability and the reduction of inflammation, postoperative fever and pain.


Assuntos
Drenagem , Fixação Interna de Fraturas , Vértebras Lombares , Parafusos Pediculares , Fraturas da Coluna Vertebral , Vértebras Torácicas , Humanos , Masculino , Vértebras Torácicas/cirurgia , Vértebras Torácicas/lesões , Fraturas da Coluna Vertebral/cirurgia , Fraturas da Coluna Vertebral/diagnóstico por imagem , Vértebras Lombares/cirurgia , Vértebras Lombares/lesões , Feminino , Estudos Retrospectivos , Adulto , Pessoa de Meia-Idade , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/efeitos adversos , Drenagem/instrumentação , Drenagem/métodos , Resultado do Tratamento , Idoso
7.
Eur Rev Med Pharmacol Sci ; 28(8): 3208-3215, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38708479

RESUMO

OBJECTIVE: We sought to explore the effectiveness of cannulated screw fixation for femoral neck fractures in middle-aged and elderly patients assisted by a three-dimensional printing navigation template. PATIENTS AND METHODS: A total of 98 middle-aged and elderly patients who underwent cannulated screw fixation for femoral neck fractures were retrospectively analyzed. They were allocated into two groups, each comprising 49 patients. Surgical indexes, hip function, and pain levels were compared between the two groups. RESULTS: The study group, assisted by the three-dimensional printing navigation template, exhibited significantly reduced nail insertion, fewer instances of C-arm fluoroscopy, shorter operation time, quicker time to bone union, earlier initiation of walking exercise, shorter time to weight-bearing walking, and reduced hospital stay than those in the control group (all p<0.001). However, the study group also experienced higher blood loss compared to the control group (p<0.001). Postoperatively, at 3 months and 12 months, the study group demonstrated significantly higher scores compared to the control group (both p<0.001) and reported significantly lower pain scores than that in the other group at 1 week and 12 months post-surgery (both p<0.001). Furthermore, the study group experienced significantly fewer postoperative complications than the control group (p=0.029). CONCLUSIONS: Cannulated screw fixation for femoral neck fractures assisted by a 3D printing navigation template is more effective and safer than traditional fixation methods. This approach represents a promising alternative for surgical management.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral , Fixação Interna de Fraturas , Impressão Tridimensional , Humanos , Fraturas do Colo Femoral/cirurgia , Pessoa de Meia-Idade , Idoso , Feminino , Masculino , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Estudos Retrospectivos
8.
PLoS One ; 19(5): e0302839, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38696506

RESUMO

PURPOSES: Fractures of the inferior patellar pole, unlike other patellar fractures, present challenges for traditional surgical fixation methods. This article introduces the clinical technique and outcomes of using Kirschner wire tension band combined with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures. METHODS: This retrospective case series study included 14 patients with comminuted inferior patellar pole fractures treated at our institution from September 1, 2020, to April 30, 2022. All patients underwent surgery using the Kirschner wire tension band with anchor screw cross-stitch technique. Follow-up assessments involved postoperative X-rays to evaluate fracture healing, as well as clinical parameters such as healing time, Visual Analog Scale (VAS) scores, range of motion (ROM), and Bostman scores. RESULTS: All patients were followed for an average of over 12 months, with no cases of internal fixation failure. Knee joint stability and function were excellent. X-rays revealed an average healing time of approximately 10.79 ± 1.53 weeks, hospitalization lasted 5.64 ± 1.15 days, surgery took approximately 37.86 ± 5.32 minutes, and intraoperative blood loss was 33.29 ± 8.15 ml. One patient experienced irritation from the internal fixation material. At the final follow-up, the Bostman score averaged 28.29 ± 0.83, knee joint flexion reached 131.07° ± 4.88°, all patients achieved full knee extension, and the VAS score was 0.36 ± 0.63. CONCLUSION: Kirschner wire tension band with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures delivered satisfactory clinical outcomes. This surgical method, characterized by its simplicity and reliability, is a valuable addition to clinical practice.


Assuntos
Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas Cominutivas , Patela , Humanos , Masculino , Feminino , Adulto , Patela/cirurgia , Patela/lesões , Fraturas Cominutivas/cirurgia , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Estudos Retrospectivos , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Resultado do Tratamento , Fraturas Ósseas/cirurgia , Consolidação da Fratura , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiopatologia , Adulto Jovem , Parafusos Ósseos , Âncoras de Sutura
9.
BMC Musculoskelet Disord ; 25(1): 350, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702748

RESUMO

BACKGROUND: Metacarpal shaft fracture is a common type of hand fracture. Numerous studies have explored fixing transverse fractures in the midshaft of the metacarpal bone. However, this section of the metacarpal bone is often susceptible to high-energy injury, resulting in comminuted fracture or bone loss. In such cases, wedge-shaped bone defects can develop in the metacarpal shaft, increasing the difficulty of performing fracture fixation. Notably, the research on this type of fracture fixation is limited. This study compared the abilities of four fixation methods to fix metacarpal shaft fractures with wedge-shaped bone defects. METHODS: In total, 28 artificial metacarpal bones were used. To create wedge-shaped bone defects, an electric saw was used to create metacarpal shaft fractures at the midshaft of each bone. The artificial metacarpal bones were then divided into four groups for fixation. The bones in the first group were fixed with a dorsal locked plate (DP group), those in the second group were fixed with a volar locked plate (VP group), and those in the third group were fixed by combining dorsal and volar locked plates (DP + VP group), and those in the fourth group were fixed with two K-wires (2 K group). Cantilever bending tests were conducted using a material testing machine to measure yielding force and stiffness. The four groups' fixation capabilities were then assessed through analysis of variance and Tukey's test. RESULTS: The DP + VP group (164.1±44.0 N) achieved a significantly higher yielding force relative to the 2 K group (50.7 ± 8.9 N); the DP group (13.6 ± 3.0 N) and VP group (12.3 ± 1.0 N) did not differ significantly in terms of yielding force, with both achieving lower yielding forces relative to the DP + VP group and 2 K group. The DP + VP group (19.8±6.3 N/mm) achieved the highest level of stiffness, and the other three groups did not differ significantly in terms of stiffness (2 K group, 5.4 ± 1.1 N/mm; DP group, 4.0 ± 0.9 N/mm; VP group, 3.9 ± 1.9 N/mm). CONCLUSIONS: The fixation method involving the combined use of dorsal and volar locked plates (DP + VP group) resulted in optimal outcomes with respect to fixing metacarpal shaft fractures with volar wedge bone defects.


Assuntos
Placas Ósseas , Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas Ósseas , Ossos Metacarpais , Ossos Metacarpais/lesões , Ossos Metacarpais/cirurgia , Humanos , Fenômenos Biomecânicos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia
10.
Sci Rep ; 14(1): 9999, 2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38693300

RESUMO

Although tension band wiring (TBW) is popular and recommended by the AO group, the high rate of complications such as skin irritation and migration of the K-wires cannot be ignored. Ding's screw tension band wiring (DSTBW) is a new TBW technique that has shown positive results in the treatment of other fracture types. The objective of this study was to evaluate the stability of DSTBW in the treatment of olecranon fractures by biomechanical testing. We conducted a Synbone biomechanical model by using three fixation methods: DSTBW, intramedullary screw and tension band wiring (IM-TBW), and K-wire TBW, were simulated to fix the olecranon fractures. We compared the mechanical stability of DSTBW, IM-TBW, and TBW in the Mayo Type IIA olecranon fracture Synbone model using a single cycle loading to failure protocol or pullout force. During biomechanical testing, the average fracture gap measurements were recorded at varying flexion angles in three different groups: TBW, IM-TBW, and DSTBW. The TBW group exhibited measurements of 0.982 mm, 0.380 mm, 0.613 mm, and 1.285 mm at flexion angles of 0°, 30°, 60°, and 90° respectively. The IM-TBW group displayed average fracture gap measurements of 0.953 mm, 0.366 mm, 0.588 mm, and 1.240 mm at each of the corresponding flexion angles. The DSTBW group showed average fracture gap measurements of 0.933 mm, 0.358 mm, 0.543 mm, and 1.106 mm at the same flexion angles. No specimen failed in each group during the cyclic loading phase. Compared with the IM-TBW and TBW groups, the DSTBW group showed significant differences in 60° and 90° flexion angles. The mean maximum failure load was 1229.1 ± 110.0 N in the DSTBW group, 990.3 ± 40.7 N in the IM-TBW group, and 833.1 ± 68.7 N in the TBW group. There was significant difference between each groups (p < 0.001).The average maximum pullout strength for TBW was measured at 57.6 ± 5.1 N, 480.3 ± 39.5 N for IM-TBW, and 1324.0 ± 43.8 N for DSTBW. The difference between maximum pullout strength of both methods was significant to p < 0.0001. DSTBW fixation provides more stability than IM-TBW and TBW fixation models for olecranon fractures.


Assuntos
Parafusos Ósseos , Fios Ortopédicos , Fixação Interna de Fraturas , Olécrano , Humanos , Olécrano/lesões , Olécrano/cirurgia , Fenômenos Biomecânicos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fraturas da Ulna/cirurgia , Fraturas da Ulna/fisiopatologia , Fraturas Ósseas/cirurgia , Fratura do Olécrano
11.
Acta Ortop Mex ; 38(1): 10-14, 2024.
Artigo em Espanhol | MEDLINE | ID: mdl-38657146

RESUMO

INTRODUCTION: health promotion policy requires the identification of barriers to the adoption of public policies. Paraguay's national healthcare system is inequitable, expensive, and inefficient. The Ministry of Public Health and Social Welfare (MSPyBS) is the entity responsible for covering the needs of a significant portion of the population. In January 2022, the MSPyBS financed the purchase of titanium elastic nails through a National Public Tender for Osteosynthesis Materials (LPN 02/22) to provide them for free in the pediatric service. Using research as a tool, we seek to analyze the impact of the implementation of LPN 02/22 at the Trauma Hospital, believing that this action would help streamline administrative and bureaucratic processes, making them more efficient with the assistance of the hospital's human resources. MATERIAL AND METHODS: a retrospective, analytical, and comparative study conducted at a high-complexity trauma center in Asunción, Paraguay. Patients aged 4 to 14 years with an indication for stabilization with elastic nails were included. Demographic data, the mechanism of injury, time elapsed from hospital arrival to surgical treatment, length of hospital stay, and the average hospital cost were analyzed based on the daily expense of pediatric patient hospitalization. RESULTS: 52 patients, divided into 25 cases in 2021 before implementation and 27 cases after implementation. The time elapsed from hospital arrival to definitive treatment was six days in the pre-implementation period, with an average stay from admission to discharge of 7.4 days. After implementation, the time from hospital arrival to definitive treatment was 4.3 days, and the average discharge time for the Post group was six days. The potential savings per patient amount to 332 dollars, offset by the institution's implant supply cost of 197 dollars, resulting in an approximate savings of 135 dollars per patient for the ministry. CONCLUSIONS: we view the implementation of free titanium elastic nails for pediatric femur fracture patients positively. We encourage the institution to continue with similar policies and strive to achieve even greater benefits for users.


INTRODUCCIÓN: la política de promoción de la salud requiere la identificación de los obstáculos para la adopción de políticas públicas. El sistema nacional de salud de Paraguay es inequitativo, caro e ineficiente. El Ministerio de Salud Pública y Bienestar Social (MSPyBS) es el ente que cubre las necesidades de gran parte de la población. El MSPyBS en Enero del 2022 financió, mediante la Licitación Pública Nacional de Materiales de Osteosíntesis (LPN 02/22), la compra de clavos elásticos de titanio para disponer de su uso gratuito en el Servicio de Pediatría; usando a la investigación como herramienta, buscamos analizar el impacto de la implementación de la LPN 02/22 en el Hospital de Trauma, creyendo que esta acción ayudaría a dinamizar los procesos administrativos y burocráticos, haciéndolos más eficientes con la ayuda de los recursos humanos del hospital. MATERIAL Y MÉTODOS: estudio retrospectivo, analítico y comparativo, realizado en un centro de trauma de alta complejidad de Asunción, Paraguay. Fueron incluidos los pacientes con edad comprendidas entre cuatro y 14 años, con indicación de estabilización con clavos elásticos. Se analizaron los datos demográficos, el mecanismo de trauma, el tiempo transcurrido desde la llegada al hospital hasta el tratamiento quirúrgico, así como el tiempo de estadía hospitalaria. Se evaluó el costo hospitalario promedio, basados en el gasto diario de la internación de un paciente pediátrico. RESULTADOS: cincuenta y dos pacientes, separados en 25 casos en el 2021 previo a la implementación y 27 casos posterior a la implementación. El tiempo transcurrido desde la llegada al hospital hasta el tratamiento definitivo fue de seis días para la etapa previa a la implementación; el promedio desde el ingreso hasta el alta fue de 7.4 días. Desde la implementación se tuvo un transcurso de 4.3 días desde la llegada al hospital hasta el tratamiento definitivo. El egreso del grupo Post tuvo un promedio de seis días. El ahorro probable en relación con cada paciente es de 332 dólares; a esto debemos contrarrestar el monto que paga la institución para la provisión del implante (197 dólares), por lo que el ahorro del ministerio sería de aproximadamente 135 dólares por cada paciente. CONCLUSIONES: vemos como positiva la implementación de la gratuidad de los clavos elásticos de titanio en los pacientes en edad pediátrica con fractura de fémur. Alentamos a la institución a seguir con políticas similares y tratar de lograr mayores beneficios para los usuarios.


Assuntos
Fraturas do Fêmur , Humanos , Criança , Estudos Retrospectivos , Adolescente , Pré-Escolar , Feminino , Masculino , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/economia , Paraguai , Tempo de Internação/estatística & dados numéricos , Pinos Ortopédicos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/economia , Fixação Interna de Fraturas/instrumentação , Custos Hospitalares/estatística & dados numéricos , Centros de Traumatologia/organização & administração , Titânio
12.
Zhongguo Gu Shang ; 37(4): 352-7, 2024 Apr 25.
Artigo em Chinês | MEDLINE | ID: mdl-38664204

RESUMO

OBJECTIVE: To compare the clinical outcomes of using elastic intramedullary nail and plate to fix fibular fracture. METHODS: The 60 patients with tibiofibular fractures admitted from January 2015 to December 2022 were divided into two groups:intramedullary nail group and plate group, 30 cases each, intramedullary nail group was treated with elastic intramedullary nail fixation group, plate group was treated with steel plate and screw fixation group. Intramedullary nail group, there were 18 males and 12 females, aged from 22 to 75 years old with an average of (39.4±9.8) years old, including 24 cases of traffic accidents injury, 6 cases of falling injury, 23 cases of closed fractures, 7 cases of open fractures. Steel plate group, there were 15 males and 15 females, aged from 24 to 78 years old with an average of (38.6±10.2) years old. The 22 cases were injured by traffic accident, 8 cases were injured by falling. The 24 cases were closed fractures and 6 cases were open fractures. The operation time, intraoperative bleeding, American Orthopedic Foot and Ankle Society (AOFAS) ankle and hind foot scores, clinical healing time of fibula and the incidence of wound complications were compared between the two groups. RESULTS: The patients in both groups were followed up for 6 to 21 months, with an average of (14.0±2.8) months. Compared with plate group, intramedullary nail group had shorter operative time, less bleeding, shorter clinical healing time of fibula, and lower infection rate of incision, and the difference was statistically significant (P<0.05). There were 2 cases of delayed healing in intramedullary nail group, 1 case of nonunion in plate group, and 2 cases of delayed healing in plate group, and there was no statistically significant difference between the two groups (P>0.05). In the last follow-up, according to the AOFAS scoring standard, the ankle function in intramedullary nail group was excellent in 17 cases, good in 12 cases, fair in 1 case, with an average of (88.33±4.57) points, while in plate group, excellent in 16 cases, good in 10 cases, fair in 4 cases, with an average of (87.00±4.14) points;There was no statistical difference between the two groups (P>0.05). CONCLUSION: Elastic intramedullary nail has the advantages of short operation time, less intraoperative bleeding, short fracture healing time and less incision complications in the treatment of fibular fracture, which is worthy of clinical application.


Assuntos
Pinos Ortopédicos , Placas Ósseas , Fíbula , Fraturas da Tíbia , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Idoso , Fíbula/lesões , Fíbula/cirurgia , Fraturas da Tíbia/cirurgia , Titânio , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/instrumentação , Adulto Jovem , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Aço
13.
J Orthop Surg Res ; 19(1): 253, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38644485

RESUMO

INTRODUCTION: We present a detailed procedure for the robotic-assisted plate osteosynthesis of an anterior acetabular fracture. The purpose of this work was to describe a robotic-assisted minimally invasive technique as a possible method for reducing complications, pain, and hospitalization. Another goal was to present technical recommendations and to assess potential pitfalls and problems of the new surgical approach. METHODS: Surgery was performed in an interdisciplinary setting by an experienced orthopedic surgeon and a urologist. The DaVinci System with standard instruments was used. Reduction was achieved through indirect traction of a pin that was introduced into the femoral neck and direct manipulation via the plate. The plate position and fixation were achieved through 7 additional minimally invasive incisions. RESULTS: The technique has multiple advantages, such as no detachment of the rectus abdominal muscle, a small skin incision, and minimal blood loss. Furthermore, this approach might lower the incidence of hernia formation, infection, and postoperative pain. DISCUSSION: We see the presented technique as a demanding yet progressive and innovative surgical method for treating acetabular fractures with indications for anterior plate fixation. TRIAL REGISTRATION: The study was approved by the local institutional review board (Nr. 248/18).


Assuntos
Acetábulo , Placas Ósseas , Fixação Interna de Fraturas , Fraturas Ósseas , Procedimentos Cirúrgicos Robóticos , Humanos , Acetábulo/cirurgia , Acetábulo/lesões , Procedimentos Cirúrgicos Robóticos/métodos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Feminino , Adulto
14.
Acta Orthop Belg ; 90(1): 102-109, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38669658

RESUMO

In 2020, the most common treatment for presumed aseptic non-union of the humeral shaft seems to be decortication, often associated with bone autografting, and stabilized by a screw plate. We propose to evaluate an original technique of rigid osteosynthesis combining intramedullary nailing and screw plate. Between January 2004 and January 2020, 45 patients underwent treatment of presumed aseptic non-union of the humeral shaft by osteosynthesis combining intramedullary nailing and a screw plate. The minimum radio-clinical follow-up was one year postoperatively. The series included 19 men and 26 women with a mean age of 53 years (range 19-84 years). Bone consolidation was achieved in 43 patients, a rate of 95.5%. Comparing patients who achieved bone consolidation with the two failed consolidations did not reveal any statistically significant factor. Interobserver agreement was almost perfect (k=0.93) for the use of the RUST for humeral shaft fractures treated with intramedullary nailing and screw plate. In our study, the treatment of presumed aseptic non- union of the humeral shaft with an osteosynthesis combining intramedullary nailing and screw plate gives, with 95.5% of bone consolidation, results equal to or even superior to the different treatments currently described in the literature.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fixação Intramedular de Fraturas , Fraturas não Consolidadas , Fraturas do Úmero , Humanos , Pessoa de Meia-Idade , Masculino , Adulto , Feminino , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/métodos , Idoso , Fraturas do Úmero/cirurgia , Idoso de 80 Anos ou mais , Fraturas não Consolidadas/cirurgia , Adulto Jovem , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Consolidação da Fratura
15.
Acta Orthop Belg ; 90(1): 110-114, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38669659

RESUMO

The aim of the study was to evaluate the results of Dorsal Wrist Plating in intra-articular distal radius fractures with a dorsal displacement. In this prospective study, a single surgeon treated 20 patients with a (partially) intra-articular distal radius fracture with a dorsal rim avulsion or a dorsal Barton's type fragment. They all underwent an open reduction and internal fixation by Dorsal Wrist Plating. A total of 17 patients had a follow-up period of at least 12 months (mean follow- up of 17 months) and these patients were included in the study. Both functional and radiological outcome parameters were measured. The total range of motion was 92 % of the contralateral side. The mean grip strength and key pinch were 24.6 kg and 6.9kg respectively compared to 29.5 kg and 7.4 kg on the non-operated side. The average Mayo Wrist Score was 89.7 (range 80-100) and the mean Disability of the Arm, Shoulder and Hand score was 4.5 (range 0-9.2). An articular step-off was only noted in 2 patients (1 and 2 mm respectively). Radial inclination was restored in all patients. Palmar tilt was anatomically restored in five patients. In all other patients, the palmar tilt was acceptably restored. There was no significant radial shortening in any of the patients. No infections, no tendon ruptures, no Complex Regional Pain Syndrome, or union problems were observed. Dorsal wrist plating seems to be a safe and reliable procedure in the treatment of intra-articular distal radius fractures with dorsal displacement.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas Intra-Articulares , Fraturas do Rádio , Amplitude de Movimento Articular , Humanos , Fraturas do Rádio/cirurgia , Masculino , Feminino , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Pessoa de Meia-Idade , Adulto , Idoso , Estudos Prospectivos , Fraturas Intra-Articulares/cirurgia , Força da Mão , Articulação do Punho/cirurgia , Articulação do Punho/fisiopatologia , Resultado do Tratamento , Adulto Jovem , Fraturas do Punho
16.
J Orthop Surg Res ; 19(1): 268, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38678298

RESUMO

BACKGROUND: Osteosynthesis for sacroiliac joint (SIJ) diastasis using an iliosacral screw (ISS) and a trans-iliac-trans-sacral screw (TITSS) can be performed using a closed or an open method. However, no clear indication for open reduction has been established. METHODS: Data on patients with unilateral traumatic SIJ diastasis who underwent ISS and TITSS fixation were retrospectively collected and separated into groups according to the reduction method: closed reduction group (C group) and open reduction group (O group). Demographic data and perioperative image assessments were compared between the groups. The critical distance of the SIJ was identified to elucidate the indication for open reduction of the diastatic SIJ. RESULTS: Fifty-six patients met the inclusion criteria over a 3-year period. There was no significant difference in the reduction quality of pelvic ring injuries between the groups, according to Matta's and Lefaivre's criteria. The improvement in the SIJ distance was significantly greater in the O group than in the C group in the axial plane on multiplanar computed tomography (p = 0.021). This model predicted that a difference of > 3.71 mm between the injured and healthy SIJ was a recommended indication for open reduction, with an area under the curve of 0.791 (95% confidence interval 0.627-0.955, p = 0.004). CONCLUSIONS: Open reduction for SIJ diastasis might achieve better reduction quality than does closed reduction in the axial plane in selected cases. When the difference between the injured and healthy SIJ was wider than 3.71 mm, open reduction was recommended for satisfactory radiological outcomes.


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas , Articulação Sacroilíaca , Humanos , Articulação Sacroilíaca/cirurgia , Articulação Sacroilíaca/lesões , Articulação Sacroilíaca/diagnóstico por imagem , Estudos Retrospectivos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Adulto Jovem , Idoso , Redução Aberta/métodos
17.
BMC Musculoskelet Disord ; 25(1): 320, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654260

RESUMO

BACKGROUND: The precise influence of plate position on clinical outcomes in the context of volar fixed-angle plating for distal radius fractures is not fully understood. This article aims to investigate the influence of plate position on clinical results, and functional outcomes in patients treated with volar fixed plating for distal radius fractures. METHODS: A total of 58 patients with 64 distal radius fractures were included in the study. Patient demographics, fracture characteristics, surgical details, and radiographic data were collected. Post-operative AP and Lat views of all patients taken on the first day after surgery were evaluated. Volar Tilt, Radial Inclination and Radial Height measurements were used as reduction criteria. In the follow-up, the patients were called for their last control, flexion and extension angles of the wrist and Mayo Wrist Scores, the distance of the plate to the joint line and the angle between the plate and the radial shaft were measured and recorded. RESULTS: A total of 64 distal radius fractures, with a mean age of 46.9 years, and the mean follow-up period 24.9 months were included in this study. There was a significant relationship between the Radial Inclination and Plate-Shaft Angle variables and the Mayo Wrist Score at a 99% confidence interval. Additionally, a relationship was observed between the Radial Height variable and the Mayo Score at a 90% confidence interval. A significant positive association was observed between radial inclination and achieving a Good-to-Excellent Mayo score (OR = 1.28, 95% CI [1.08-1.51], p = 0.004). Plate distance to joint line demonstrated a marginally significant positive association with a Good-to-Excellent Mayo score (OR = 1.31, 95% CI [0.97-1.77], p = 0.077). Univariate analysis revealed a significant negative association between plate-shaft angle and achieving a Good-to-Excellent Mayo score (OR = 0.71, 95% CI [0.52-0.99], p = 0.045). This negative association remained statistically significant in the multivariate analysis (p = 0.016). CONCLUSION: Radial inclination, plate distance to joint line, and angle between plate and radius shaft were identified as significant factors associated with improved Mayo Wrist Scores.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas do Rádio , Humanos , Fraturas do Rádio/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Adulto , Idoso , Resultado do Tratamento , Seguimentos , Estudos Retrospectivos , Amplitude de Movimento Articular , Adulto Jovem , Fraturas do Punho
18.
Int Orthop ; 48(6): 1501-1506, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38561523

RESUMO

PURPOSE: There is no consensus on the optimal treatment of bony mallet finger in the paediatric population due to a lack of studies in children. The Ishiguro technique is simple and less invasive, and treatment with K-wire fixation seems to provide better results for extension lag in bony mallet finger according to the literature. A retrospective cross-sectional study with long-term follow-up was performed to evaluate the functional and clinical outcomes of this method in children. Preoperative and intraoperative predictors of outcome were investigated. METHODS: From June to December 2022, we evaluated 95 children who underwent extension K-wire block from 2002 to 2012. Eighty-four children were included (mean age 14.8 ± 1.68 years) for a mean long-term follow-up of 11.6 ± 2.3 (8-16) years. Clinical and radiographic features were assessed. Pain and functional outcomes were assessed using Crawford criteria, range of motion (ROM) at the distal interphalangeal joint (DIPJ), loss of extension, and VAS scale. Univariate and multivariate regressions were used to assess which variables might predict the worst outcomes at long-term follow-up. RESULTS: Bone union and pain relief were always achieved. There were no complaints of potential growth impairment or nail deformity. 82.1% of patients showed excellent and good results. Fifteen patients had fair results. CONCLUSIONS: Although there are currently no significant differences between surgery and orthosis in adults, the Ishiguro technique is more effective in children when it comes to outcomes in the treatment of mallet fingers. A high percentage of excellent and good results were achieved, and no epiphyseal damage or nail deformity was reported. A strong and significant correlation was found between the worst outcomes and either delayed treatment time or excessive flexion angle.


Assuntos
Fios Ortopédicos , Amplitude de Movimento Articular , Humanos , Estudos Retrospectivos , Feminino , Masculino , Adolescente , Seguimentos , Criança , Estudos Transversais , Amplitude de Movimento Articular/fisiologia , Resultado do Tratamento , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Traumatismos dos Dedos/cirurgia , Traumatismos dos Dedos/terapia , Articulações dos Dedos/cirurgia , Articulações dos Dedos/fisiopatologia
19.
J Orthop Surg Res ; 19(1): 271, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38689343

RESUMO

BACKGROUND: Precise and minimally invasive closed reduction is the premise of minimally invasive internal fixation. This paper aims to explore the safety and efficacy of a robot-assisted fracture reduction system (RAFR) in the treatment of pelvic fractures and to analyze its clinical advantages and existing problems. METHODS: The RAFR system intelligently designed the optimal reduction path and target position based on a preoperative three-dimensional(3D) CT scan of the patient. The reduction robotic arm automatically reduced the affected hemipelvis according to the pre-planned reduction path. RESULTS: The average residual displacement was the 6.65 ± 3.59 mm. According to Matta's criteria, there were 7 excellent, 10 good, and 3 fair, and the excellent and good rate was 85%. No postoperative complications occurred. CONCLUSION: In our study, the RAFR system could complete accurate and minimally invasive closed reduction for most patients with unstable pelvic fractures, which could achieve good fracture reduction quality and short-term efficacy.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Procedimentos Cirúrgicos Robóticos , Humanos , Ossos Pélvicos/lesões , Ossos Pélvicos/cirurgia , Ossos Pélvicos/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fraturas Ósseas/diagnóstico por imagem , Procedimentos Cirúrgicos Robóticos/métodos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Idoso
20.
Arch Orthop Trauma Surg ; 144(5): 2119-2125, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38492060

RESUMO

INTRODUCTION: The aim of this study is to assess the risk of peroneal artery injury of hardware placement at the fixation of syndesmotic injuries. MATERIALS AND METHODS: The lower extremity computed tomography angiography was used to design the study. The syndesmosis screw placement range was simulated every 0.5 cm, from 0.5 to 5 cm proximal to the ankle joint. The screw axes were drawn as 20°, 30° or individual angle according to the femoral epicondylar axis. The proximity between the screw axis and the peroneal artery was measured in millimeters. Potential peroneal artery injury was noted if the distance between the peroneal artery to the axis of the simulated screw was within the outer shaft radius of the simulated screw. The Pearson chi-square test was used and a p-value < 0.05 was considered significant. RESULTS: The potential for injury to the peroneal artery increased as the syndesmosis screw level rose proximally from the ankle joint level or as the diameter of the syndesmosis screw increasds. In terms of syndesmosis screw trajection, the lowest risk of injury was observed with the syndesmosis screw angle of 20°. Simulations with a screw diameter of 3.5 mm exhibited the least potential for peroneal artery injury. CONCLUSION: Thanks to this radiological anatomy simulation study, we believe that we have increased the awareness of the peroneal artery potential in syndesmosis screw application. Each syndesmosis screw placement option may have different potential for injury to the peroneal artery. To decrease the peroneal artery injury potential, we recommend the followings. If individual syndesmosis screw angle trajection can be measured, place the screw 1.5 cm proximal to the ankle joint using a 3.5 mm screw shaft. If not, fix it with 30° trajection regardless of the screw diameter at the same level. If the most important issue is the peroneal artery circulation, use the screw level up to 1 cm proximal to the ankle joint regardless of the screw angle trajection and screw diameter.


Assuntos
Parafusos Ósseos , Angiografia por Tomografia Computadorizada , Humanos , Parafusos Ósseos/efeitos adversos , Angiografia por Tomografia Computadorizada/métodos , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/prevenção & controle , Lesões do Sistema Vascular/diagnóstico por imagem , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/efeitos adversos , Traumatismos do Tornozelo/cirurgia , Traumatismos do Tornozelo/diagnóstico por imagem , Artérias/lesões , Artérias/diagnóstico por imagem , Artérias/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA