Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.505
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 353, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38724941

RESUMO

BACKGROUND: External fixation is widely used in the treatment of traumatic fractures; however, orthopedic surgeons encounter challenges in deciding the optimal time for fixator removal. The axial load-share ratio (LS) of the fixator is a quantitative index to evaluate the stiffness of callus healing. This paper introduces an innovative method for measuring the LS and assesses the method's feasibility and efficacy. Based on a novel hexapod LS-measurement system, the proposed method is to improve the convenience and precision of measuring LS in vivo, hence facilitating the safe removal of external fixators. METHODS: A novel hexapod system is introduced, including its composition, theoretical model, and method for LS measurement. We conducted a retrospective study on 82 patients with tibial fractures treated by the Taylor Spatial Frame in our hospital from September 2018 to June 2020, of which 35 took LS measurements with our novel method (Group I), and 47 were with the traditional method (Group II). The external fixator was removed when the measurement outcome (LS < 10%) was consistent with the surgeon's diagnosis based on the clinical and radiological assessment (bone union achieved). RESULTS: No significant difference was found in the fracture healing time (mean 25.3 weeks vs. 24.9 weeks, P > 0.05), frame-wearing duration (mean 25.5 weeks vs. 25.8 weeks, P > 0.05), or LS measurement frequency (mean 1.1 times vs. 1.2 times, P > 0.05). The measurement system installation time in Group I was significantly shorter compared to Group II (mean 14.8 min vs. 81.3 min, P < 0.001). The LS value of the first measurement in Group I was lower than that of Group II (mean 5.1% vs. 6.9%, P = 0.011). In Group I, the refracture rate was 0, but in Group II it was 4.3% (2/47, P > 0.05). CONCLUSION: The novel hexapod LS-measurement system and involved method demonstrated enhanced convenience and precision in measuring the LS of the external fixator in vivo. The LS measurement indicates the callus stiffness of fracture healing, and is applicable to evaluate the safety of removing the fixator. Consequently, it is highly recommended for widespread adoption in clinical practice.


Assuntos
Remoção de Dispositivo , Fixadores Externos , Fixação de Fratura , Consolidação da Fratura , Fraturas da Tíbia , Humanos , Feminino , Fraturas da Tíbia/cirurgia , Masculino , Estudos Retrospectivos , Adulto , Pessoa de Meia-Idade , Fixação de Fratura/instrumentação , Fixação de Fratura/métodos , Remoção de Dispositivo/métodos , Suporte de Carga , Adulto Jovem , Idoso , Estudos de Viabilidade , Desenho de Equipamento
2.
Medicine (Baltimore) ; 103(18): e37979, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38701293

RESUMO

Older children over 8 years old are at higher risk of elbow joint stiffness after treatment of supracondylar humeral fractures. The objective of this study was to improve the Slongo's external fixation system for treating supracondylar humeral fractures in older children. This would be achieved by increasing fixation strength and providing a theoretical basis through finite element analysis and mechanical testing. A 13-year-old female patient with a history of previous fracture was selected for CT data processing to create a three-dimensional model of the distal humerus fracture. Two internal fixation models were established, using the Slongo's external fixation method with Kirschner wire (Group A) and modifying the Slongo's external fixation (Kirschner wire tail fixation) (Group B). The fracture models were then subjected to mechanical loading analysis using Finite Element Analysis Abaqus 6.14 software to simulate separation, internal rotation, and torsion loads. A PVC humeral bone model was used to create a supracondylar fracture model, and the A and B internal fixation methods were applied separately. The anterior-posterior and torsional stresses were measured using the Bose Electroforce3510 testing system, followed by a comparative analysis. The finite element simulation results showed that under the same tensile, torsion, and inversion forces, the osteotomy model fixed with Kirschner wire at the distal end in Group B exhibited smaller tensile stress and deformation compared to the unfixed osteotomy model in Group A. This indicated that the fixation strength of Group B was superior to that of Group A. According to the test results of the Bose Electroforce3510 testing system, a simple linear regression analysis was conducted using SPSS software. The K values of rotation angle-torque tests and front and rear displacement-stress tests were calculated for Groups A and B, with Group B showing higher values than Group A. The results of this study supported the significantly enhanced biomechanical reliability and stability of fracture fixation in Group B, which utilized the modified Slongo's external fixation (Kirschner wire tail fixation). This optimized method provides a new choice for the clinical treatment of supracondylar humeral fractures in older children, backed by both clinical evidence and theoretical basis.


Assuntos
Fixadores Externos , Análise de Elementos Finitos , Fixação de Fratura , Fraturas do Úmero , Humanos , Fraturas do Úmero/cirurgia , Feminino , Adolescente , Fixação de Fratura/métodos , Fios Ortopédicos , Fenômenos Biomecânicos , Tomografia Computadorizada por Raios X
5.
Sci Rep ; 14(1): 9544, 2024 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664538

RESUMO

To compare the biomechanical properties of several anterior pelvic ring external fixators with two new configurations in the treatment of Tile C pelvic fractures, in order to evaluate the effectiveness of the new configurations and provide a reference for their clinical application. A finite element model of a Tile C pelvic ring injury (unilateral longitudinal sacral fracture and ipsilateral pubic fracture) was constructed. The pelvis was fixed with iliac crest external fixator (IC), anterior inferior iliac spine external fixator (AIIS), combination of IC and AIIS, combination of anterior superior iliac spine external fixator (ASIS) and AIIS, and S1 sacroiliac screw in 5 types of models. The stability indices of the anterior and posterior pelvic rings under vertical longitudinal load, left-right compression load and anterior-posterior shear load were quantified and compared. In the simulated bipedal standing position, the results of the vertical displacement of the midpoint on the upper surface of the sacrum are consistent with the displacement of the posterior rotation angle, and the order from largest to smallest is IC, AIIS, ASIS + AIIS, IC + AIIS and S1 screw. The longitudinal displacement of IC is greater than that of the other models. The displacements of ASIS + AIIS and IC + AIIS are similar and the latter is smaller. In the simulated semi-recumbent position, the vertical displacement and posterior rotation angle displacement of the midpoint on the upper surface of the sacrum are also consistent, ranking from large to small: IC, AIIS, ASIS + AIIS, IC + AIIS and S1 screw. Under the simulated left-right compression load state, the lateral displacements of the highest point of the lateral sacral fracture end are consistent with the highest point of the lateral pubic fracture end, and the order from large to small is S1 screw, IC, AIIS, ASIS + AIIS and IC + AIIS, among which the displacements of S1 screw and IC are larger, and the displacements of ASIS + AIIS and IC + AIIS are similar and smaller than those of other models. The displacements of IC + AIIS are smaller than those of ASIS + AIIS. Under the simulated anterior-posterior shear load condition, the posterior displacements of the highest point of the lateral sacral fracture end and the highest point of the lateral pubic fracture end are also consistent, ranking from large to small: IC, AIIS, ASIS + AIIS, IC + AIIS and S1 screw. Among them, the displacements of IC and AIIS are larger. The displacements of ASIS + AIIS and IC + AIIS are similar and the latter are smaller. For the unstable pelvic injury represented by Tile C pelvic fracture, the biomechanical various stabilities of the combination of IC and AIIS are superior to those of the external fixators of conventional configurations. The biomechanical stabilities of the combination of ASIS and AIIS are also better than those of the external fixators of conventional configurations, and slightly worse than those of the combination of IC and AIIS. Compared with sacroiliac screw and conventional external fixators, the lateral stabilities of IC + AIIS and ASIS + AIIS are particularly prominent.


Assuntos
Fixadores Externos , Fraturas Ósseas , Ossos Pélvicos , Humanos , Fenômenos Biomecânicos , Ossos Pélvicos/lesões , Ossos Pélvicos/cirurgia , Fraturas Ósseas/cirurgia , Fixação de Fratura/métodos , Fixação de Fratura/instrumentação , Análise de Elementos Finitos , Sacro/lesões , Sacro/cirurgia , Parafusos Ósseos
6.
Proc Inst Mech Eng H ; 238(4): 403-411, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38602217

RESUMO

External fixation is an essential surgical technique for treating trauma, limb lengthening and deformity correction, however infection is common, with infection rates ranging from 4.5 to 100% of cases. Throughout the literature researchers and clinicians have highlighted a relationship between excessive movement of the pin and skin and an increase in the patient's risk of infection, however, currently no studies have addressed this role of pin-movement on pin-site wounds. This preliminary study describes a novel in vitro pin-site model, developed using a full-thickness human skin equivalent (HSE) model in conjunction with a bespoke mechanical system which simulates pin-movement. The effect of pin-movement on the wound healing response of the skin equivalents was assessed by measuring the expression of pro-inflammatory cytokines. Six human skin equivalent models were divided into three test groups: no pin as the control, static pin-site wound and dynamic pin-site wound (n = 3). On day 3 concentrations of IL-1α and IL-8 showed a significant increase compared to the control when a static fixation pin was implanted into the skin equivalent (p < 0.05) and (p < 0.005) respectively. Levels of IL-1α and IL-8 increased further in the dynamic sample compared to the static sample (p < 0.05) and (p < 0.0005). This study demonstrates for the first time the application of HSE model to study external-fixation pin-movement in vitro. The results of this study demonstrated pin-movement has a negative effect on soft-tissue wound-healing, supporting the anecdotal evidence reported in the literature, however further analysis of wound heading would be required to verify this hypothesis.


Assuntos
Fixadores Externos , Fixação de Fratura , Humanos , Fixação de Fratura/métodos , Infecção da Ferida Cirúrgica/terapia , Interleucina-8 , Pinos Ortopédicos , Cicatrização/fisiologia
7.
J Pak Med Assoc ; 74(3): 440-444, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38591274

RESUMO

Objective: To determine the combined column tibial plateau fracture treated with a hybrid external fixator in terms of knee functionality, union outcome and complications. METHODS: The quasi-experimental study was conducted at the Department of Orthopaedic Surgery, Mayo Hospital, Lahore, Pakistan, from July 5, 2019, to December 31, 2021, and comprised patients of either gender aged 20-50 years who presented with 2-column or 3-column fractures of proximal tibia classified according to the 3-column classification system after being diagnosed using radiographs and three-dimensional computed tomography scan. Knee function, union and complications, like neural, vascular, infection, delayed union, nonunion, malunion and implant failure, were evaluated. The Knee Society Score was used to assess knee function, and modified Rasmussen score for the union, while complications were assessed clinically on the 2nd, 6th, 12th, 16th, 24th, 36th weeks and one year post-operatively. Data was analysed using SPSS 26. RESULTS: Of the 113 patients, 91(80.53%) were males and 22(19.47%) were females. The overall mean age was 35.56±9.00 years. From the 12th week to the 24th week 45(39.83%) patients had good and 59(52.21%) patients had excellent functional outcomes. Union outcome in the 16th and 24th week was good in 57(50.44%) patients and excellent in 47(41.59%) patients. No neurovascular injury was observed. Superficial pin tract infection was observed in 21(18.6%) cases that healed with wound debridement and antibiotics. No delayed union, malunion and implant failure was observed. CONCLUSIONS: Good to excellent functional and union outcomes with minimum complications were observed with the hybrid external fixator.


Assuntos
Fraturas da Tíbia , Fraturas do Planalto Tibial , Masculino , Feminino , Humanos , Adulto , Resultado do Tratamento , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Fixadores Externos , Fixação de Fratura/métodos , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos
8.
J Back Musculoskelet Rehabil ; 37(3): 611-616, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38517767

RESUMO

BACKGROUND: The clavicle is recognized as the bone most vulnerable to fractures. Moreover, approximately 80% of fractures occur in the middle third of the clavicle. Conservative treatment is associated with a higher rate of nonunion, while surgical treatment of fracture via internal fixation may have a variety of postoperative complications. Therefore, to improve patient satisfaction and reduce the complications related to internal fixation techniques, we modified the surgical approach to external fixation. OBJECTIVE: The purpose of this study was to assess the modified intervention's prospects for clinical application. METHODS: A total of 36 patients with middle clavicle fractures were treated with screw-rod external fixation between April 2015 and October 2019. We observed the operative time, intraoperative blood loss, length of hospital stay, and fracture healing time. The patients were followed up regularly, and the clinical efficacy of the modified intervention was evaluated. Finally, the patients' shoulder function was assessed based on the disabilities of the arm, shoulder, and hand (DASH) score. RESULTS: For the screw-rod external fixation, the mean operative time was found to be 48.6 ± 6.8 min, the intraoperative blood loss was 30.6 ± 17.2 mL, the length of hospital stay was 4.5 ± 1.5 days, and the fracture healing time was 2.8 ± 0.4 months. Eventually, all the patients healed well, with the combined "excellent" and "good" rate of shoulder function being assessed to be as high as 94.44%. Furthermore, the DASH scores were all less than 10, with the average score being 4.65 ± 3.34. CONCLUSIONS: The screw-rod external fixation technique offers the advantages of convenience, reliability, and good aesthetics, suggesting that it could be used as an alternative treatment method for fractures of the middle third of the clavicle.


Assuntos
Clavícula , Fraturas Ósseas , Humanos , Clavícula/lesões , Clavícula/cirurgia , Feminino , Masculino , Adulto , Fraturas Ósseas/cirurgia , Pessoa de Meia-Idade , Fixação de Fratura/métodos , Consolidação da Fratura/fisiologia , Duração da Cirurgia , Tempo de Internação , Resultado do Tratamento , Parafusos Ósseos , Fixação Interna de Fraturas/métodos
9.
Foot Ankle Int ; 45(5): 446-455, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501715

RESUMO

BACKGROUND: For the temporary treatment of ankle fracture dislocations (AFDs), previous studies indicate higher rates of secondary loss of reduction (LOR) with splint immobilization, prompting consideration for expanding indications for external fixation (ExFix). However, these studies did not investigate the influence of fracture morphology to further improve patient selection. The aim of this study was to investigate the influence of Lauge-Hansen injury type on the LOR rate in bimalleolar or trimalleolar AFDs for temporary cast vs ExFix immobilization. METHODS: In this retrospective cohort study, patients with isolated AFD cases treated at our institution from 2011 to 2020 were reviewed. Inclusion criteria required radiographs depicting initial dislocation and appropriate reduction after Cast or ExFix immobilization. Exclusion criteria encompassed concomitant injuries, open fractures, conservative management as well as surgery performed within 48 hours or at a different facility. Patients were grouped by temporary treatment (Cast or ExFix). The primary endpoint was LOR prior to definitive surgery across various Lauge-Hansen types. RESULTS: The LOR rate was significantly higher in the cast group (40/152, 26.3%) compared to the ExFix group (5/191, 2.6%; P < .0001). In the cast group, LOR was associated with an increase in time to definitive surgery by a mean of 3 days (P < .002). During cast treatment, LOR was significantly more likely for pronation abduction (P = .001) and supination external rotation injuries (P < .0001), whereas no significant differences were observed for pronation external rotation (P = .006), supination adduction (P > .99), and fractures not classifiable (P > .99). CONCLUSION: In cases of AFDs resulting from supination external rotation or pronation abduction trauma according to the Lauge-Hansen classification, especially in the setting of an additional posterior malleolar fracture, primary application of external fixation should be considered to reduce the risk for secondary loss of reduction. LEVEL OF EVIDENCE: Level III, retrospective cohort study.


Assuntos
Fraturas do Tornozelo , Moldes Cirúrgicos , Fratura-Luxação , Humanos , Fraturas do Tornozelo/cirurgia , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Fratura-Luxação/cirurgia , Fixação de Fratura/métodos , Idoso , Estudos de Coortes
10.
Artigo em Inglês | MEDLINE | ID: mdl-38537115

RESUMO

INTRODUCTION: External fixation of unstable ankle injuries is commonly done by orthopaedic surgeons. An improper technique can negate the benefits of the procedure and necessitate revision. This study sought to determine the risk factors for revision of external fixation of unstable ankle injuries. METHODS: Retrospective cohort at a level I academic trauma center of 120 consecutive patients underwent external fixation of an unstable ankle injury. Exclusion criteria included external fixation for reason other than fracture, inadequate intraoperative imaging, skeletal immaturity, and follow-up less than 30 days. Primary outcome measurement was revision of external fixation within 30 days. RESULTS: Ninety-seven patients met inclusion criteria. Eighteen (18.6%) underwent revision within 30 days of whom 5 (28%, P < 0.001) had a poor reduction intraoperatively. No patients with a good reduction required revision. Revised patients had a significantly higher talar tilt (P < 0.001) and were more likely to lack a first metatarsal pin (P = 0.018). Multivariate analysis revealed talar tilt >0.5° (odds ratio, 22.62; 95% confidence interval, 6.52 to 50.63) as an independent risk factor for revision. DISCUSSION: For external fixation of unstable ankle injuries, poor reduction quality is a risk factor for need for revision surgery. Orthopaedic surgeons should be critical of their final intraoperative assessment to prevent revision.


Assuntos
Traumatismos do Tornozelo , Fixação de Fratura , Humanos , Estudos Retrospectivos , Fixação de Fratura/métodos , Fixadores Externos , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/cirurgia , Fatores de Risco
11.
J Mech Behav Biomed Mater ; 153: 106488, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38437754

RESUMO

INTRODUCTION: This systematic review aims to identify previously used techniques in biomechanics to assess pelvic instability following pelvic injury, focusing on external fixation constructs. METHODS: A systematic literature search was conducted to include biomechanical studies and to exclude clinical trials. RESULTS: Of an initial 4666 studies found, 38 met the inclusion criteria. 84% of the included studies were retrieved from PubMed, Scopus, and Web of Science. The studies analysed 106 postmortem specimens, 154 synthetic bones, and 103 computational models. Most specimens were male (97% synthetic, 70% postmortem specimens). Both the type of injury and the classification system employed varied across studies. About 82% of the injuries assessed were of type C. Two different fixators were tested for FFPII and type A injury, five for type B injury, and fifteen for type C injury. Large variability was observed for external fixation constructs concerning device type and configuration, pin size, and geometry. Biomechanical studies deployed various methods to assess injury displacement, deformation, stiffness, and motion. Thereby, loading protocols differed and inconsistent definitions of failure were determined. Measurement techniques applied in biomechanical test setups included strain gauges, force transducers, and motion tracking techniques. DISCUSSION AND CONCLUSION: An ideal fixation method should be safe, stable, non-obstructive, and have low complication rates. Although biomechanical testing should ensure that the load applied during testing is representative of a physiological load, a high degree of variability was found in the current literature in both the loading and measurement equipment. The lack of a standardised test design for fixation constructs in pelvic injuries across the studies challenges comparisons between them. When interpreting the results of biomechanical studies, it seems crucial to consider the limitations in cross-study comparability, with implications on their applicability to the clinical setting.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Humanos , Fenômenos Biomecânicos , Fixadores Externos , Fixação de Fratura/métodos , Ossos Pélvicos/cirurgia
12.
Med Sci Monit ; 30: e944136, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38549240

RESUMO

BACKGROUND Tibial fractures, common in adults, are often treated with external or internal fixation methods. While effective, external fixation (EF) can lead to sexual dysfunction (SD), especially in young patients. This study aimed to assess SD in women undergoing EF versus internal fixation for tibial fractures. MATERIAL AND METHODS Sexual function and frequency of monthly sexual intercourse (SI) were evaluated using the Female Sexual Function Index (FSFI) before surgery, with the fixator, after at least 6 months following fixator removal in EF group, and after achieving bone union for at least 3 months in the IF group. RESULTS The EF group consisted of 107 (mean age 28.5 years; 19-40 years) and IF group consisted of 106 patients (mean age 32.1 years; 18-40 years). The duration of EF was an average of 4.7 months (range, 2.5-13 months). FSFI scores were significantly lower in the EF group compared to the IF group (9.33 versus 27.3, P<0.001). Also, there was no significant difference between the FSFI scores before EF and after EF was removed (34.22 versus 33.8, P=0.413). FSFI sub-group scores such as desire, arousal, lubrication, and orgasm were significantly lower in the EF group (P<0.001). The monthly average frequency of SI before surgery and after the removal of EF was 10.2 and 9.1, respectively, while this frequency was 2.56 when EF was present (P<0.001). CONCLUSIONS The quality and frequency of SI in women significantly deteriorate and decrease during the period of extremity fixation following tibial diaphyseal fractures treated with EF, but return to normal after removal.


Assuntos
Disfunções Sexuais Fisiológicas , Fraturas da Tíbia , Adulto , Humanos , Feminino , Estudos Retrospectivos , Fixadores Externos , Fraturas da Tíbia/complicações , Fraturas da Tíbia/cirurgia , Fixação Interna de Fraturas/métodos , Fixação de Fratura/métodos , Resultado do Tratamento
14.
JBJS Case Connect ; 14(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38484095

RESUMO

CASE: A 23-year-old right-hand dominant man presented with a high-velocity gunshot wound injury to the right thumb with severe soft-tissue damage, vascular injury, and large osseous defect of the right thumb metacarpal. The patient was successfully treated with metacarpophalangeal joint arthrodesis and metacarpal reconstruction using definitive external fixation, an intramedullary Kirschner wire, and use of the Masquelet bone grafting technique. CONCLUSION: The authors' treatment approach for a mangled thumb injury with definitive external fixation and utilization of the Masquelet technique resulted in restoration of a large osseous defect, avoidance of infection, and limited loss of mobility.


Assuntos
Traumatismos da Mão , Procedimentos de Cirurgia Plástica , Ferimentos por Arma de Fogo , Humanos , Masculino , Adulto Jovem , Fixadores Externos , Fixação de Fratura/métodos , Traumatismos da Mão/cirurgia , Polegar/cirurgia , Ferimentos por Arma de Fogo/cirurgia
15.
Injury ; 55(4): 111391, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38377672

RESUMO

OBJECTIVE: To analyze the application value of damage control strategies combining pre-hospital emergency treatment with in-hospital treatment for multiple injuries in treating pelvic fracture complicated by multiple injuries. METHODS: 120 patients with pelvic fracture complicated by multiple injuries admitted to our hospital from January 2020 to January 2023 were selected and divided into a damage control group (early temporary reduction after resuscitation, n = 60) and a control group (no reduction and resuscitation only, n = 60) by treatment methods. The control group was treated with conventional methods, while the damage control group was treated with the damage control strategy combining pre-hospital emergency treatment combined with in-hospital treatment in addition to conventional methods. The mortality rate, complication rate, fracture reduction quality, long-term efficacy, and patient satisfaction of the two groups were compared. RESULTS: The mortality rate of the damage control group was lower than that of the control group, and the difference has statistical significance (P<0.05); the incidence of infection, DIC, and MODS of the damage control group were lower than that of the control group, with the difference being statistically significant (P<0.05); the incidence of ARDS in the two groups is not that different (P>0.05); the fracture reduction quality and long-term therapeutic effect of patients in the two groups were statistically different, with the damage control group outperforming the control group in both aspects; the difference between the two groups in terms of patient satisfaction was statistically significant (P<0.05), with the patient satisfaction of the damage control group being higher than that of the control group. CONCLUSION: For patients with pelvic fracture, the application of the damage control strategy combining pre-hospital emergency treatment and in-hospital treatment is a boon to the standardization of the treatment process, the improvement of the treatment success rate and fracture reduction quality and the reduction of complications, and therefore is worth promoting in clinical practice. the early application of external fixation has helped with the definitive reduction at a time when the patuent was stable.


Assuntos
Fraturas Ósseas , Traumatismo Múltiplo , Ossos Pélvicos , Humanos , Fraturas Ósseas/terapia , Fraturas Ósseas/cirurgia , Ossos Pélvicos/lesões , Fixação de Fratura/métodos , Resultado do Tratamento , Hospitais , Traumatismo Múltiplo/terapia , Traumatismo Múltiplo/cirurgia , Estudos Retrospectivos , Fixação Interna de Fraturas
16.
J Orthop Trauma ; 38(5): 254-258, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38378177

RESUMO

OBJECTIVES: To compare cost, hospital-related outcomes, and mortality between angioembolization (AE) and preperitoneal pelvic packing (PPP) in the setting of pelvic ring or acetabulum fractures. METHODS: . DESIGN: Retrospective database review. SETTING: National Inpatient Sample, years 2016-2020. PATIENT SELECTION CRITERIA: Hospitalized adult patients who underwent AE or PPP in the setting of a pelvic ring or acetabulum fracture. OUTCOME MEASURES AND COMPARISONS: Mortality and hospital-associated outcomes, including total charges, following AE versus PPP in the setting of pelvic ring or acetabulum fractures. RESULTS: A total of 3780 patients, 3620 undergoing AE and 160 undergoing PPP, were included. No significant differences in mortality, length of stay, time to procedure, or discharge disposition were found ( P > 0.05); however, PPP was associated with significantly greater charges than AE ( P = 0.04). Patients who underwent AE had a mean total charge of $250,062.88 while those undergoing PPP had a mean total charge of $369,137.16. CONCLUSIONS: Despite equivalent clinical efficacy in terms of mortality and hospital-related outcomes, PPP was associated with significantly greater charges than AE in the setting of pelvic ring or acetabulum fractures. This data information can inform clinical management of these patients and assist trauma centers in resource allocation. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Ossos Pélvicos , Fraturas da Coluna Vertebral , Adulto , Humanos , Fraturas Ósseas/complicações , Fixação de Fratura/métodos , Acetábulo/lesões , Estudos Retrospectivos , Ossos Pélvicos/lesões , Fraturas do Quadril/complicações , Fraturas da Coluna Vertebral/complicações
17.
Proc Inst Mech Eng H ; 238(2): 187-197, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38314816

RESUMO

This paper presents the outcome of a data review of patients treated with the IOS external fixation system at the Royal Stoke University Hospital: a fixation designed to meet four requirements for external fixation proposed in this paper. Demographic data and outcome were collected and assessed. From 69 initial patients, 64 patients (55 males and 9 females) had an average age of 35.9 years. The mean time to union was 127 days. There were no incidences of malunion, or refracture post fixation removal attributable to the treatment method. In addition, in this cohort, there was no incidence of pin tract infection resulting in osteomyelitis. Of all the factors assessed the only factor to have any significant effect on healing was smoking: an average delay of 31 days. An examination of RUST (radiographic union score tibia) and modified RUST scores illustrated a potential false negative of up to 80%. Hence, this study cannot support the use of either scoring system to diagnose fracture healing. IOS external fixation was shown to be an effective method for the treatment of unstable tibial fractures. The reduction at fixation removal was shown to be very good. There was no incidence of osteomyelitis. It is, therefore, suggested that appropriately used external fixation is a viable alternative to intramedullary nailing if designed and surgically applied using four design principles outlined in this paper. Furthermore, it is proposed that external fixation be designed and applied to meet these four principles.


Assuntos
Fixação Intramedular de Fraturas , Osteomielite , Fraturas da Tíbia , Masculino , Feminino , Humanos , Adulto , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Tíbia , Fixação de Fratura/métodos , Consolidação da Fratura , Osteomielite/etiologia , Resultado do Tratamento , Fixadores Externos
18.
J Trauma Acute Care Surg ; 96(5): 694-701, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38227676

RESUMO

ABSTRACT: Patients with multisystem injuries are defined as multiply injured patients and may need multiple surgical procedures from more than one specialty. The importance of evaluating and understanding the resuscitation status of a multiple-injury patient is critical. Orthopedic strategies when caring for these patients include temporary stabilization or definitive early fixation of fractures while preventing further insult to other organ systems. This article will define multiple injuries and discuss specific markers used in assessing patients' hemodynamic and resuscitation status. The decision to use damage-control orthopedics or early total care for treatment of the patient are based on these factors, and an algorithm is presented to guide treatment. We will also discuss principles of external fixation and the management of pelvic trauma in a multiple-injury patient.


Assuntos
Traumatismo Múltiplo , Humanos , Traumatismo Múltiplo/terapia , Traumatismo Múltiplo/diagnóstico , Procedimentos Ortopédicos/métodos , Fixação de Fratura/métodos , Ressuscitação/métodos , Fraturas Ósseas/terapia , Fraturas Ósseas/cirurgia , Algoritmos , Hemodinâmica/fisiologia
19.
BMC Musculoskelet Disord ; 25(1): 104, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38297262

RESUMO

BACKGROUND: The shortcomings of plaster in water resistance, air permeability, skin comfort, fixed stability and weight of wearing are still to be solved. 3D printed cast can overcome the above shortcomings. At present, there is a relative lack of data on the clinical application of 3D printed cast, probably due to its complexity, relatively long operating time, and high price. We aimed to compare and evaluate the short-term effectiveness, safety and advantages of 3D printed wrist cast versus polymer orthosis in the treatment of Colles fracture. METHODS: Forty patients with Colles fracture in our hospital from June to December 2022 were selected and divided into an observation group (20 patients, treated with instant 3D printed cast) and a control group (20 cases, treated with polymer orthosis). Both groups treated with manual reduction and external fixation. The visual analogue scale (VAS), immobilization effectiveness and satisfaction scores, Disability of the Arm, Shoulder and Hand (DASH) score, complications and imaging data were collected and compared before immobilization and at 2, 6 and 12 weeks after the fracture. RESULTS: VAS at 2 weeks after the fracture was significantly lower in the observation group than in the control group ( P < 0.05). The immobilization effectiveness and satisfaction scores at 6 weeks after the fracture were significantly higher in the observation group than in the control group (all P < 0.05). The DASH scores at 2 and 6 weeks after the fracture were significantly lower in the observation group than in the control group (all P < 0.05). There wasn't rupture of the printed cast or orthosis in both groups. There were 2 cases of skin irritation in the control group, and no skin irritation occurred in the observation group. The palmar tilt angle and ulnar inclination angle at 2 weeks and 12 weeks after the fracture were significantly higher in the observation group than in the control group (all P < 0.05). CONCLUSIONS: Both instant 3D printed cast and polymer orthosis are effective in the treatment of Colles fracture. But instant 3D printed cast is better than polymer orthosis in areas of good clinical and imaging performance, and high patient satisfaction and comfort.


Assuntos
Fratura de Colles , Fraturas do Rádio , Humanos , Fratura de Colles/cirurgia , Aparelhos Ortopédicos , Braquetes , Fixação de Fratura/métodos , Impressão Tridimensional , Resultado do Tratamento , Fraturas do Rádio/cirurgia , Moldes Cirúrgicos
20.
JBJS Case Connect ; 14(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38271549

RESUMO

CASE: The authors present 3 physiologically young patients with displaced femoral neck fractures who underwent initial closed reduction and provisional fixation. Multidimensional fluoroscopy was used to assess fracture reduction before definitive fixation, with 1 patient requiring an open approach because of inadequate fracture reduction after closed attempts. CONCLUSION: Displaced femoral neck fractures in young patients remain difficult injuries to treat. Reduction quality is a significant predictor of patient outcomes. Intraoperative multidimensional fluoroscopy provides treating surgeons with a tool to assess fracture reduction after closed reduction maneuvers and allows for intraoperative treatment adjustment as needed.


Assuntos
Fraturas do Colo Femoral , Fixação Interna de Fraturas , Humanos , Fixação Interna de Fraturas/métodos , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia , Fixação de Fratura/métodos , Fluoroscopia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA