Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Interact Cardiovasc Thorac Surg ; 32(3): 426-432, 2021 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-33831214

RESUMO

OBJECTIVES: We herein report a single-centre experience with the SAPIEN 3 Ultra balloon-expandable transcatheter aortic valve implantation (TAVI) system. METHODS: Between March 2019 and January 2020, a total of 79 consecutive patients received transfemoral TAVI using the SAPIEN 3 Ultra device. Data were retrospectively analysed according to updated Valve Academic Research Consortium-2 definitions. Detailed analysis of multislice computed tomography data was conducted to identify potential predictors for permanent pacemaker (PPM) implantation and residual paravalvular leakage (PVL) post TAVI. RESULTS: Device success and early safety were 97.5% (77/79) and 94.9% (75/79) with resulting transvalvular peak/mean pressure gradients of 21.1 ± 8.2/10.9 ± 4.4 and PVL >mild in 0/79 patients (0%). Mild PVL was seen in 18.9% (15/79) of cases. Thirty-day mortality was 2.5% (2/79). The Valve Academic Research Consortium-2 adjudicated clinical end points disabling stroke, acute kidney injury and myocardial infarction occurred in 1.3% (1/79), 5.1% (4/79) and 0% (0/79) of patients. Postprocedural PPM implantation was necessary in 7.6% (6/79) of patients. Multislice computed tomography analysis revealed significantly higher calcium amounts of the right coronary cusp in patients in need for postprocedural PPM implantation and a higher eccentricity index in patients with postinterventional mild PVL. CONCLUSIONS: First experience with this newly designed balloon-expandable-transcatheter heart valve demonstrates adequate 30-day outcomes and haemodynamic results with low mortality, low rates of PPM implantation and no residual PVL >mild. The herein-presented multislice computed tomography values with an elevated risk for PPM implantation and residual mild PVL may help to further improve outcomes with this particular transcatheter heart valve in TAVI procedures.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Comércio/tendências , Próteses Valvulares Cardíacas/tendências , Tomografia Computadorizada Multidetectores/tendências , Desenho de Prótese/tendências , Idoso , Idoso de 80 Anos ou mais , Comércio/métodos , Feminino , Fluoroscopia/métodos , Fluoroscopia/tendências , Seguimentos , Humanos , Masculino , Tomografia Computadorizada Multidetectores/métodos , Desenho de Prótese/métodos , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Am J Gastroenterol ; 116(1): 100-105, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32947320

RESUMO

INTRODUCTION: The global needs for a reduction in radiation exposure (RE) are increasing. Endoscopic retrograde cholangiopancreatography (ERCP) is a significant fluoroscopic procedure in the gastrointestinal field. However, the actual RE in ERCP and its annual trend are still unclear. Therefore, we examined the yearly trend of RE in ERCP. METHODS: This retrospective, single-center cohort study included consecutive cases of ERCP from September 2012 to June 2019. We measured the air kerma (AK, mGy), dose area product (DAP, Gycm2), and fluoroscopy time (FT, min). We also evaluated the annual trend of the RE before and after the fluoroscopy device update. RESULTS: In total, 2,174 patients receiving ERCP were enrolled. Among these, the mean age was 74.3 years, and 913 patients were women (42.0%). The median/third quartile values of AK (mGy), DAP (Gycm2), and FT (min) were 109/234 mGy, 13.3/25.8 Gycm2, and 18.2/27.7 minutes. The annual AK, DAP, and FT from 2012 to 2019 were 138, 207, 173, 177, 106, 71.0, 45.0, and 33.3 mGy; 23, 21.4, 19, 18.3, 11.9, 9.0, 6.8, and 6.4 Gycm2; and 12.5, 12.1, 9.7, 9.8, 8.2, 10.8, 9.4, and 10.3 minutes, respectively. The corresponding values before and after the update in July 2016 were 177 and 52 mGy (P < 0.0001), 19.2 and 7.6 Gycm2 (P < 0.0001), and 10.2, and 9.9 minutes (P = 0.05), respectively. DISCUSSION: The RE from ERCP tended to decrease every year, especially after fluoroscopy device updates.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica/tendências , Fluoroscopia/tendências , Doses de Radiação , Exposição à Radiação/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluoroscopia/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo
3.
J Neurointerv Surg ; 13(4): 390-394, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32675383

RESUMO

BACKGROUND: Spinal angiography (SA) is associated with low complications in adults but its safety in children has not been properly analyzed. The goal of our study is to assess the safety of pediatric SA. METHODS: This study is the retrospective analysis of a series of 36 consecutive SA procedures performed in 27 children over a 5-year period. Parameters including neurological complications, non-neurological complications requiring additional management, contrast volume, and radiation exposure were analyzed via univariate and bivariate methods. RESULTS: Our cohort included 24 diagnostic and 12 combined therapeutic cases in children with an average age of 11.1 years. No neurological or non-neurological complication requiring additional management was recorded. The average volume of contrast administered was 1.6 mL/kg in the diagnostic group and 0.9 mL/kg in the combined group. The average air kerma was 186.9mGy for an average of 36.8 exposures in the diagnostic group, and 264.5mGy for an average of 21 exposures in the combined group. Patients in the combined group had lower contrast load (45% lower on average) and higher air kerma (1.6 times higher on average). The difference in air kerma was due to a higher live fluoroscopy-related exposure. CONCLUSIONS: This study reports the largest pediatric SA cohort analyzed to date and the only one including radiation dose and contrast load. It confirms that pediatric SA is a safe imaging modality with low risk of complications, and demonstrates that SA can be performed in children with low radiation exposure and contrast load.


Assuntos
Angiografia/tendências , Hemangioma/diagnóstico por imagem , Doses de Radiação , Exposição à Radiação , Medula Espinal/diagnóstico por imagem , Adolescente , Angiografia/efeitos adversos , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Fluoroscopia/efeitos adversos , Fluoroscopia/tendências , Humanos , Lactente , Masculino , Exposição à Radiação/efeitos adversos , Estudos Retrospectivos
4.
World Neurosurg ; 140: 664-673, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32445895

RESUMO

BACKGROUND: The desire to improve accuracy and safety and to favor minimally invasive techniques has given rise to spinal robotic surgery, which has seen a steady increase in utilization in the past 2 decades. However, spinal surgery encompasses a large spectrum of operative techniques, and robotic surgery currently remains confined to assistance with the trajectory of pedicle screw insertion, which has been shown to be accurate and safe based on class II and III evidence. The role of robotics in improving surgical outcomes in spinal pathologies is less clear, however. METHODS: This comprehensive review of the literature addresses the role of robotics in surgical outcomes in spinal pathologies with a focus on the various meta-analysis and prospective randomized trials published within the past 10 years in the field. RESULTS: It appears that robotic spinal surgery might be useful for increasing accuracy and safety in spinal instrumentation and allows for a reduction in surgical time and radiation exposure for the patient, medical staff, and operator. CONCLUSION: Robotic assisted surgery may thus open the door to minimally invasive surgery with greater security and confidence. In addition, the use of robotics facilitates tireless repeated movements with higher precision compared with humans. Nevertheless, it is clear that further studies are now necessary to demonstrate the role of this modern tool in cost-effectiveness and in improving clinical outcomes, such as reoperation rates for screw malpositioning.


Assuntos
Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/tendências , Doenças da Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/tendências , Fluoroscopia/instrumentação , Fluoroscopia/tendências , Humanos , Monitorização Neurofisiológica Intraoperatória/instrumentação , Monitorização Neurofisiológica Intraoperatória/tendências , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/tendências , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos , Doenças da Coluna Vertebral/diagnóstico por imagem , Resultado do Tratamento
5.
J Laryngol Otol ; 134(4): 350-353, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32172698

RESUMO

OBJECTIVES: Pharyngocutaneous fistulae are dreaded complications following total laryngectomy. This paper presents our experience using 3-5 ml gastrografin to detect pharyngeal leaks following total laryngectomy, and compares post-operative videofluoroscopy with clinical follow-up findings in the detection of pharyngocutaneous fistulae. METHODS: A retrospective case-control study was conducted of total laryngectomy patients. The control group (n = 85) was assessed clinically for development of pharyngocutaneous fistulae, while the study group (n = 52) underwent small-volume (3-5 ml) post-operative gastrografin videofluoroscopy. RESULTS: In the control group, 24 of 85 patients (28 per cent) developed pharyngocutaneous fistulae, with 6 requiring surgical correction. In the study group, 24 of 52 patients (46 per cent) had videofluoroscopy-detected pharyngeal leaks; 4 patients (8 per cent) developed pharyngocutaneous fistulae, but all cases resolved following non-surgical management. Patients who underwent videofluoroscopy had a significantly lower risk of developing pharyngocutaneous fistulae; sensitivity and specificity in the detection of pharyngocutaneous fistulae were 58 per cent and 100 per cent respectively. CONCLUSION: Small-volume gastrografin videofluoroscopy reliably identified small pharyngeal leaks. Routine use in total laryngectomy combined with withholding feeds in cases of early leaks may prevent the development of pharyngocutaneous fistulae.


Assuntos
Fístula Cutânea/diagnóstico por imagem , Diatrizoato de Meglumina/administração & dosagem , Fluoroscopia/métodos , Laringectomia/efeitos adversos , Doenças Faríngeas/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Fístula Cutânea/prevenção & controle , Fístula Cutânea/terapia , Feminino , Fluoroscopia/tendências , Humanos , Masculino , Programas de Rastreamento/instrumentação , Pessoa de Meia-Idade , Faringe/diagnóstico por imagem , Faringe/patologia , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Sensibilidade e Especificidade
6.
Radiol Med ; 125(3): 296-305, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31845091

RESUMO

The advances in technology have led to a growing trend in population exposure to radiation emerging from the invention of high-dose procedures. It is, for example, estimated that annually 1.2% of cancers are induced by radiological scans in Norway. This study aims to investigate and discuss the frequency and dose trends of radiological examinations in Europe. European Commission (EC) launched projects to gain information for medical exposures in 2004 and 2011. In this study, the European Commission Radiation Protection (RP) reports No. 154 and 180 have been reviewed. The RP 154 countries' data were extracted from both reports, and the average variation trend of the number of examinations and effective doses were studied. According to the results, plain radiography and fluoroscopy witnessed a reduction in the frequency and effective dose per examination. Nevertheless, European collective dose encountered an average increase of 23%, which resulted from a growing tendency for implementation of high-dose procedures such as CT scans and interventional examinations. It is worth noting that most of the CT procedures have undergone an increase in effective dose per examination. Although demand and dose per examination in some radiological procedures (such as intravenous urography (IVU) have been reduced, population collective dose is still rising due to the increasing demand for CT scan procedures. Even though the individual risks are not considerable, it can, in a large scale, threaten the health of the people at the present time. Due to this fact, better justification should be addressed so as to reduce population exposure.


Assuntos
Exposição à Radiação/estatística & dados numéricos , Radiografia Intervencionista/tendências , Radiografia/tendências , Tomografia Computadorizada por Raios X/tendências , Europa (Continente)/epidemiologia , Fluoroscopia/estatística & dados numéricos , Fluoroscopia/tendências , Humanos , Neoplasias Induzidas por Radiação/epidemiologia , Noruega/epidemiologia , Doses de Radiação , Proteção Radiológica , Radiografia/estatística & dados numéricos , Radiografia Intervencionista/estatística & dados numéricos , Radiologia/tendências , Tomografia Computadorizada por Raios X/estatística & dados numéricos
7.
Rofo ; 191(6): 512-521, 2019 Jun.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-30703826

RESUMO

BACKGROUND: The increasing number of minimally invasive fluoroscopy-guided interventions is likely to result in higher radiation exposure for interventional radiologists and medical staff. Not only the number of procedures but also the complexity of these procedures and therefore the exposure time as well are growing. There are various radiation protection means for protecting medical staff against scatter radiation. This article will provide an overview of the different protection devices, their efficacy in terms of radiation protection and the corresponding dosimetry. METHOD: The following key words were used to search the literature: radiation protection, eye lens dose, radiation exposure in interventional radiology, cataract, cancer risk, dosimetry in interventional radiology, radiation dosimetry. RESULTS AND CONCLUSION: Optimal radiation protection always requires a combination of different radiation protection devices. Radiation protection and monitoring of the head and neck, especially of the eye lenses, is not yet sufficiently accepted and further development is needed in this field. To reduce the risk of cataract, new protection glasses with an integrated dosimeter are to be introduced in clinical routine practice. KEY POINTS: · A combination of personal radiation protection devices and optimized dosimetry improves the safety of medical staff.. CITATION FORMAT: · König AM, Etzel R, Thomas RP et al. Personal Radiation Protection and Corresponding Dosimetry in Interventional Radiology: An Overview and Future Developments. Fortschr Röntgenstr 2019; 191: 512 - 521.


Assuntos
Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Radiologia Intervencionista , Radiometria/métodos , Fluoroscopia/tendências , Previsões , Alemanha , Humanos , Lesões por Radiação/etiologia , Radiologia Intervencionista/tendências , Radiometria/tendências , Espalhamento de Radiação
8.
J Neurointerv Surg ; 10(12): e36, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29572266

RESUMO

BACKGROUND AND PURPOSE: Onyx embolization is a treatment for brain arteriovenous malformations (AVMs). However, multistage embolization usually involves the presence of radiodense Onyx cast from the previous sessions, which may influence the fluoroscopic radiation dose. We compared the fluoroscopic dose between the initial and final embolization sessions. MATERIALS AND METHOD: From January 2014 to September 2016, 18 patients underwent multistage Onyx embolization (more than twice) for brain AVMs. The total fluoroscopic duration (minutes), dose-area product (DAP, Gy×cm2), and cumulative air kerma (CAK, mGy) of both the frontal and lateral planes were obtained. We compared the frontal and lateral fluoroscopic dose rates (dose/time) of the final embolization session with those of the initial session. The relationship between the injected Onyx volume and radiation dose was tested. RESULTS: The initial and final procedures on the frontal plane showed significantly different fluoroscopic dose rates (DAP: initial 0.668 Gy×cm2/min, final 0.848 Gy×cm2/min, P=0.02; CAK: initial 12.7 mGy/min, final 23.1 mGy/min, P=0.007). Those on the lateral plane also showed a similar pattern (DAP: initial 0.365 Gy×cm2/min, final 0.519 Gy×cm2/min, P=0.03; CAK: initial 6.2 mGy/min, final 12.9 mGy/min, P=0.01). The correlation between the cumulative Onyx volume (vials) and radiation dose ratio of both planes showed an increasing trend (rho 0.4325-0.7053; P=0.0011-0.0730). CONCLUSION: Owing to the automatic exposure control function during fluoroscopy, successive Onyx embolization procedures increase the fluoroscopic radiation dose in multistage brain AVM embolization because of the presence of radiodense Onyx mass.


Assuntos
Fístula Arteriovenosa/terapia , Embolização Terapêutica/tendências , Malformações Arteriovenosas Intracranianas/terapia , Polivinil , Doses de Radiação , Tantálio , Adolescente , Adulto , Fístula Arteriovenosa/diagnóstico por imagem , Combinação de Medicamentos , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Feminino , Fluoroscopia/efeitos adversos , Fluoroscopia/métodos , Fluoroscopia/tendências , Humanos , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
9.
World Neurosurg ; 109: e24-e32, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28951183

RESUMO

BACKGROUND: Recent studies have shown higher accuracy rates of image-guided pedicle screw placement compared to freehand (FH) placement. However, data focusing on the impact of spinal navigation on the rate of revision surgeries caused by misplaced pedicle screws (PS) are scarce. OBJECTIVE: This study is aimed at identifying the rate of revision surgeries for misplaced PS comparing three-dimensional (3D) fluoroscopy navigation (3DFL) with FH PS placement. METHODS: A retrospective analysis was conducted of 2232 patients (mean age, 65.3 ± 13.5 years) with 13,703 implanted PS who underwent instrumentation of the thoracolumbar spine between 2007 and 2015. Group 1 received surgery with use of 3DFL (January 2011 to December 2015), group 2 received surgery in the FH technique (April 2007 to December 2015). Because the use of 3DFL was initiated in January 2011, the examined period for 3DFL-navigated surgeries is shorter. Patients routinely received postoperative computed tomography scans and/or intraoperative control 3D scans. RESULTS: There was an overall rate of revision surgeries for malpositioned PS of 2.9%. In the 3DFL group, the rate of secondary revision surgeries was significantly lower with 1.35% (15/1112 patients) compared to 4.38% (49/1120 patients) in the FH group, respectively (odds ratio, 3.35; P < 0.01). Of all PS in the 3DFL group (30/7548 PS), 0.40% needed revision surgery (P < 0.01) compared to 1.14% in the FH group (70/6155 PS). CONCLUSIONS: We were able to show that the use of 3DFL-navigated PS placement significantly reduces the rate of revision surgeries after posterior spinal instrumentation compared to freehand PS placement.


Assuntos
Monitorização Neurofisiológica Intraoperatória/tendências , Vértebras Lombares/cirurgia , Neuronavegação/tendências , Parafusos Pediculares , Reoperação/tendências , Vértebras Torácicas/cirurgia , Idoso , Feminino , Fluoroscopia/normas , Fluoroscopia/tendências , Humanos , Imageamento Tridimensional/normas , Imageamento Tridimensional/tendências , Monitorização Neurofisiológica Intraoperatória/normas , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Neuronavegação/normas , Parafusos Pediculares/efeitos adversos , Estudos Retrospectivos , Cirurgia Assistida por Computador/normas , Cirurgia Assistida por Computador/tendências , Vértebras Torácicas/diagnóstico por imagem
10.
J Endourol ; 31(7): 623-629, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28401803

RESUMO

The prevalence of urinary stones in the United States has been described as 1 in 11 persons reporting a history of stones. Imaging plays a crucial role in diagnosis, management, and follow-up for these patients and imaging technology over the last 100 years has advanced as the disease prevalence has increased. CT remains the gold standard for imaging urolithiasis and changes in this technology, with the addition of multidetector CT and dual-energy CT, as well as the changes in utilization of CT, have decreased the radiation dose encountered by patients and allowed for improved stone detection. The use of digital tomography has been introduced for follow-up of recurrent stone formers offering the potential to lower radiation exposure over the course of a patient's lifelong treatment. However, there is still a demand for improved imaging techniques to detect smaller stones and stones in larger patients at lower radiation doses as well as the continued need for the judicious use of all imaging modalities for healthcare cost containment and patient safety.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Urolitíase/diagnóstico por imagem , Fluoroscopia/métodos , Fluoroscopia/tendências , Humanos , Exposição à Radiação/prevenção & controle , Radiografia Abdominal/métodos , Radiografia Abdominal/tendências , Tomografia Computadorizada por Raios X/tendências
11.
Semin Speech Lang ; 38(2): 135-146, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28324903

RESUMO

Speech-language pathologists (SLPs) have fulfilled primary roles in the evaluation and management of children with feeding/swallowing disorders for more than five decades. The increased incidence and prevalence of newborns, infants, and children with feeding and swallowing disorders has resulted in increased use of instrumental swallowing evaluations. The videofluoroscopic swallow study and fiberoptic endoscopic evaluation of swallowing are the two most commonly used swallowing assessments by SLPs, with ultrasound used less frequently. This article focuses on updates over the past decade in the procedures and utility of instrumental assessments of swallowing function, and identifies future directions that may enable us to meet the needs of the children who are in our care to attain functional outcomes.


Assuntos
Transtornos de Deglutição/diagnóstico , Transtornos de Alimentação na Infância/diagnóstico , Avaliação das Necessidades/tendências , Patologia da Fala e Linguagem/tendências , Criança , Pré-Escolar , Estudos Transversais , Transtornos de Deglutição/epidemiologia , Transtornos de Deglutição/terapia , Endoscopia/instrumentação , Endoscopia/tendências , Transtornos de Alimentação na Infância/epidemiologia , Transtornos de Alimentação na Infância/terapia , Fluoroscopia/instrumentação , Fluoroscopia/tendências , Previsões , Humanos , Lactente , Recém-Nascido , Patologia da Fala e Linguagem/instrumentação , Gravação em Vídeo/instrumentação , Gravação em Vídeo/tendências
12.
Pain Med ; 18(7): 1326-1333, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28034968

RESUMO

BACKGROUND: The challenge of obtaining medical imaging in individuals with higher body mass index (BMI) is described, but there is minimal data regarding the relationship between BMI and fluoroscopy time during cervical interlaminar epidural steroid injection (CIESI). OBJECTIVE: To determine the relationship between BMI and fluoroscopy time during CIESI. METHODS: Retrospective cohort study of patients who underwent fluoroscopically guided CIESI between January 2014 and February 2015 at an academic pain medicine center. Fluoroscopy time data were collected. Comparisons based on analysis of variance were made between patients with normal (<25.0 kg/m 2 ), overweight (25.0-29.9 kg/m 2 ), and obese (≥30.0 kg/m 2 ) BMI. RESULTS: Of 399 procedure encounters, 366 had documented BMI and fluoroscopy time data and were included for analysis. Mean age (± SD) in this cohort was 53 ± 13 years, including 189 females (52%) and 205 first-time injections. Mean fluoroscopy time for all injections was 18 ± 10 seconds. Separated by categorical BMI class, the mean fluoroscopy time was 18 ± 9 seconds for normal weight patients, 17 ± 10 seconds for overweight patients, and 20 ± 11 seconds for obese patients, respectively. Post hoc analysis showed that fluoroscopy time was significantly longer only in obese compared with overweight patients ( P = 0.02). Trainee involvement and first-time vs repeat injection did not significantly alter fluoroscopy time ( P = 0.17 and P = 0.12, respectively). CONCLUSIONS: The findings of this study indicate that BMI does not appear to have a clinically significant impact on fluoroscopy time during cervical interlaminar epidural steroid injection procedures. Future study is needed to directly quantify radiation exposure in patients and practitioners, as well as the associated health risk.


Assuntos
Índice de Massa Corporal , Vértebras Cervicais/diagnóstico por imagem , Fluoroscopia/tendências , Sobrepeso/diagnóstico por imagem , Esteroides/administração & dosagem , Adulto , Idoso , Estudos de Coortes , Feminino , Humanos , Injeções Epidurais , Masculino , Pessoa de Meia-Idade , Sobrepeso/tratamento farmacológico , Estudos Retrospectivos , Fatores de Tempo
13.
Unfallchirurg ; 120(Suppl 1): 5-9, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27619985

RESUMO

Three-dimensional (3D) imaging can enhance trauma care by allowing better evaluation of bony detail and implant position compared to conventional fluoroscopy or x­ray. Intraoperative 3D imaging further improves this evaluation by allowing any necessary revisions to be made in the operating room prior to the patient emerging from anesthesia. This revision, if necessary, better achieves the surgical goals and alleviates the stressful situation of obtaining postoperative 3D imaging, where the benefit of revision must be balanced against the cost and risk of returning to the operating room. Improved image volume, resolution, and software capability have allowed surgeons to obtain high-quality, wide field views of bony anatomy that can include the uninjured side as a comparison. In this paper, the evolution of intraoperative 3D imaging over the past 25 years is discussed.


Assuntos
Fluoroscopia/tendências , Imageamento Tridimensional/tendências , Complicações Intraoperatórias/diagnóstico por imagem , Complicações Intraoperatórias/cirurgia , Tomografia Computadorizada por Raios X/tendências , Ferimentos e Lesões/diagnóstico por imagem , Ferimentos e Lesões/cirurgia , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/tendências , Desenho de Equipamento , Fluoroscopia/instrumentação , Humanos , Imageamento Tridimensional/instrumentação , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Reoperação , Sensibilidade e Especificidade , Ossos do Tarso/diagnóstico por imagem , Ossos do Tarso/lesões , Ossos do Tarso/cirurgia , Tomografia Computadorizada por Raios X/instrumentação
14.
Bull Hosp Jt Dis (2013) ; 74(2): 124-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27281316

RESUMO

OBJECTIVES: The purpose of this survey was to learn more about the indications, criteria, and methods surgeons use for performing examination under anesthesia (EUA) for "intermediate" sized posterior wall acetabular fractures (those involving 20% to 40% of the posterior wall) and to find what criteria are used to determine hip instability. METHODS: An 18 question survey was posted on the Ortho- paedic Trauma Association's website and was used to gather anonymous data from orthopaedic surgeons regarding their approach to the intermediate sized posterior wall fracture. RESULTS: Considerable variability existed among re- sponses to many of the questions asked. Based on the an - swers given to the survey, a consensus of 75% or more of respondents was found for the following: 1. Supine position for the examination (100%); 2. "Live" fluoroscopy is used during the examination (97%); 3. The AP and obturator oblique are the x-rays most frequently used (81% and 76%, respectively); 4. The hip is placed in flexion and adduction during the exam (100% and 84%, respectively); 5. Axial load is applied during the examination (90%); Finally, 6. instabil - ity is defined as subluxation on exam by most respondents (98%), and any perceived visible subluxation is what defines instability (88%). CONCLUSION: Most surgeons agreed with the following: 1. Supine is the position of choice for the examination; 2. "Live" fluoroscopy is used during the examination; 3. The AP and obturator oblique are the x-rays most frequently used; 4. The hip is placed in flexion and adduction during the exam; 5. Axial load is applied during the examination; and 6. Instability is defined as subluxation on exam.


Assuntos
Acetábulo , Anestesia Geral/tendências , Fraturas Ósseas/diagnóstico , Articulação do Quadril , Instabilidade Articular/diagnóstico , Cirurgiões Ortopédicos/tendências , Padrões de Prática Médica/tendências , Acetábulo/diagnóstico por imagem , Acetábulo/lesões , Acetábulo/fisiopatologia , Fenômenos Biomecânicos , Fluoroscopia/tendências , Fraturas Ósseas/fisiopatologia , Fraturas Ósseas/cirurgia , Pesquisas sobre Atenção à Saúde , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Articulação do Quadril/cirurgia , Humanos , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Posicionamento do Paciente/tendências , Valor Preditivo dos Testes , Amplitude de Movimento Articular , Decúbito Dorsal , Tomografia Computadorizada por Raios X/tendências
15.
J Am Coll Radiol ; 13(8): 894-903, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27084072

RESUMO

PURPOSE: To assess changing utilization patterns of abdominal imaging in the Medicare fee-for-service population over the past two decades. METHODS: Medicare Physician Supplier Procedure Summary master files from 1994 through 2012 were used to study changes in the frequency and utilization rates (per 1,000 Medicare beneficiaries per year) of abdominal CT, MRI, ultrasound, and radiography. RESULTS: In Medicare beneficiaries, the most frequently performed abdominal imaging modality changed from radiography in 1994 (207.4 per 1,000 beneficiaries) to CT in 2012 (169.0 per 1,000). Utilization rates of abdominal MR (1037.5%), CT (197.0%), and ultrasound (38.0%) all increased from 1994-2012 (but declined briefly from 2007 to 2009). A dramatic 20-year utilization rate decline occurred for gastrointestinal fluoroscopic examinations (-91.9% barium enema, -80.0% upper gastrointestinal series) and urologic radiographic examinations (-95.3%). Radiologists were the dominant providers of all modalities, accounting for >90% of CT and MR studies, and >75% of most ultrasound examination types. CONCLUSIONS: Medicare utilization of abdominal imaging has markedly changed over the past two decades, with overall dramatic increases in CT and MRI and dramatic decreases in gastrointestinal fluoroscopic and urologic radiographic imaging. Despite these changes, radiologists remain the dominant providers in all abdominal imaging modalities.


Assuntos
Abdome/diagnóstico por imagem , Diagnóstico por Imagem/estatística & dados numéricos , Diagnóstico por Imagem/tendências , Planos de Pagamento por Serviço Prestado/estatística & dados numéricos , Benefícios do Seguro/estatística & dados numéricos , Medicare/estatística & dados numéricos , Fluoroscopia/estatística & dados numéricos , Fluoroscopia/tendências , Humanos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Imageamento por Ressonância Magnética/tendências , Radiografia Abdominal/estatística & dados numéricos , Radiografia Abdominal/tendências , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Tomografia Computadorizada por Raios X/tendências , Ultrassonografia/estatística & dados numéricos , Ultrassonografia/tendências , Estados Unidos/epidemiologia , Urografia/estatística & dados numéricos , Urografia/tendências , Revisão da Utilização de Recursos de Saúde
17.
Reg Anesth Pain Med ; 41(1): 75-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26650427

RESUMO

BACKGROUND: Lumbar interlaminar epidural steroid injections (ESIs) are one of the most commonly performed procedures in pain medicine, but little is known about the serum levels of steroids following injection into the epidural space. The primary objective of this study was to investigate the pharmacokinetics of fluoroscopy-guided epidural-administered triamcinolone acetonide in a cohort of patients with chronic low-back pain seeking treatment in a pain medicine clinic. METHODS: The study cohort included 10 patients undergoing a fluoroscopically guided L4-L5 or L5-S1 lumbar interlaminar ESI at a pain medicine specialty clinic. Blood was collected prior to the ESI and on days 1, 2, 4, 6, 8, 14, 21, 28, 35, and 42 following the injection. The sample extract was analyzed by tandem mass spectrometry. RESULTS: The terminal elimination half-life of epidural-administered triamcinolone in a noncompartmental analysis was 523 hours. In the noncompartmental analysis, peak triamcinolone concentrations of 4.1 ng/mL were detected within 24 hours after administration. CONCLUSIONS: The pharmacokinetics of epidural-administered triamcinolone is consistent with previously observed adverse effects of the drug on endocrine function. The pharmacokinetics of other epidural-administered steroids should be determined and incorporated in clinical trials to investigate the potential associations between serum levels, clinical outcomes, and potential adverse endocrine effects.


Assuntos
Dor Lombar/sangue , Dor Lombar/tratamento farmacológico , Triancinolona Acetonida/administração & dosagem , Triancinolona Acetonida/sangue , Adulto , Estudos de Coortes , Feminino , Fluoroscopia/tendências , Humanos , Injeções Epidurais , Dor Lombar/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade
19.
Acta Cardiol ; 70(3): 299-306, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26226703

RESUMO

OBJECTIVE: Although many patients benefit greatly from fluoroscopically guided intervention (IVR) procedures such as percutaneous coronary intervention (PCI), one of the major disadvantages associated with these procedures, such as cardiac IVR, is the increased patient radiation dose. This study compared the entrance surface doses of x-ray equipment for cardiac IVR at the same seven cardiac catheterization laboratories between today and the past to determine the radiation doses of current cardiac IVR x-ray systems. METHODS AND RESULTS: This study was conducted in 2001, 2007, and 2014 at the same seven cardiac catheterization laboratories in and around Sendai City, Japan. The entrance surface doses with cineangiography and fluoroscopy were compared in 2001 (11 x-ray systems), 2007, and 2014 (12 x-ray systems) using a 20-cm-thick acrylic plate and skin dose monitor. The x-ray conditions used in the measurements, including the image receptor field magnification mode and the recording speed for cineangiography and fluoroscopy, were those-normally used in the facilities performing PCI. Although presently, the entrance doses of x-ray equipment used for cardiac IVR tend to be lower than previously (fluoroscopy dose in 2001, 19.3 +/- 6.3 mGy/min; in 2014, 13.2 +/- 6.5 mGy/min), some equipment has a high radiation dose. In addition, the dose differences of the x-ray systems in 2014 were greater than those in the past (fluoroscopy dose in 2001, 3.4-fold; in 2014, 10.5-fold). CONCLUSIONS: In IVR procedures, managing the radiation dose of cardiac IVR x-ray systems is a very important issue. Periodical measurement of the radiation dose of the x-ray equipment used for both cineangiography and fluoroscopy for cardiac IVR is necessary.


Assuntos
Coração/diagnóstico por imagem , Doses de Radiação , Radiologia Intervencionista , Cineangiografia/tendências , Fluoroscopia/tendências , Humanos , Radiologia Intervencionista/instrumentação , Radiologia Intervencionista/tendências
20.
Catheter Cardiovasc Interv ; 85(3): 393-9, 2015 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-24407867

RESUMO

BACKGROUND: The impact of operator experience on fluoroscopy time and contrast utilization during percutaneous coronary intervention (PCI) of coronary chronic total occlusions (CTOs) has received limited study. METHODS: We evaluated temporal trends in fluoroscopy time and contrast utilization among 1,363 consecutive CTO PCIs performed at three US institutions between January 2006 and November 2011. RESULTS: Mean age was 65 ± 11 years, 85% of patients were men, 40% had diabetes, 37% had prior coronary artery bypass graft surgery, and 42% had prior PCI. The CTO target vessel was the right coronary artery (55%), circumflex (23%), left anterior descending artery (21%), and left main or bypass graft (1%). The retrograde approach was used in 34% of all procedures. The technical and procedural success rates were 85.5 and 84.2%, respectively. The mean procedural time, fluoroscopy time, and contrast utilization were 113 ± 61 min, 42 ± 29 min, and 294 ± 158 mL, respectively. Years since initiation of CTO PCI were independently associated with higher technical success rate (odds ratio [OR] = 1.52, 95% confidence interval [CI] = 1.52-1.70, P < 0.001), lower fluoroscopy time (OR = 0.84, 95% CI = 0.75-0.95, P = 0.005), and contrast utilization (OR = 0.84, 95% CI = 0.62-0.79, P < 0.001) during the study period. CONCLUSIONS: Among selected US-based institutions performing CTO PCI, we observed a significant reduction in total fluoroscopy time and contrast utilization paralleled with an improved technical success rate over time.


Assuntos
Meios de Contraste , Angiografia Coronária/tendências , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Intervenção Coronária Percutânea/tendências , Padrões de Prática Médica/tendências , Radiografia Intervencionista/tendências , Idoso , Distribuição de Qui-Quadrado , Competência Clínica , Meios de Contraste/efeitos adversos , Angiografia Coronária/efeitos adversos , Feminino , Fluoroscopia/tendências , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Doses de Radiação , Radiografia Intervencionista/efeitos adversos , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS