Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 965
Filtrar
1.
Tidsskr Nor Laegeforen ; 144(7)2024 Jun 04.
Artigo em Inglês, Norueguês | MEDLINE | ID: mdl-38832610

RESUMO

Background: While most cases of venous thromboembolism follow a benign course, occasionally the condition may manifest a complex clinical presentation and need a comprehensive diagnostic workup to identify the underlying cause and provide the patient with appropriate treatment. Case presentation: A woman in her late thirties presented to the emergency department with a five-day history of dyspnoea. She had recently undergone liposuction surgery after pregnancy. Upon admission, initial investigations revealed a pulmonary embolism with right heart strain, and she was treated with anticoagulants. The following day, she complained of acute-onset right flank pain without fever or other accompanying symptoms. A CT scan of the abdomen confirmed a right-side renal infarction. Further investigations revealed patent foramen ovale between the right and left atria of the heart, believed to be the source of a right-to-left shunt of arterial emboli. Although the patient had not suffered a clinical stroke, it was decided to close this defect using percutaneous technique. Interpretation: Patent foramen ovale is a common condition in adults, but in most cases it remains asymptomatic. However, patients with patent foramen ovale have an elevated risk of arterial emboli affecting multiple organs. The diagnosis depends on thorough assessment to prevent potentially fatal outcomes.


Assuntos
Abdominoplastia , Dispneia , Forame Oval Patente , Embolia Pulmonar , Humanos , Feminino , Adulto , Forame Oval Patente/complicações , Forame Oval Patente/cirurgia , Forame Oval Patente/diagnóstico por imagem , Dispneia/etiologia , Abdominoplastia/efeitos adversos , Embolia Pulmonar/etiologia , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Infarto/etiologia , Infarto/diagnóstico por imagem , Infarto/diagnóstico , Infarto/cirurgia , Complicações Pós-Operatórias
2.
Neurology ; 102(10): e209388, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38701403

RESUMO

BACKGROUND AND OBJECTIVES: Whether patent foramen ovale (PFO) closure benefits older patients with PFO and cryptogenic stroke is unknown because randomized controlled trials (RCTs) have predominantly enrolled patients younger than 60 years of age. Our objective was to estimate anticipated effects of PFO closure in older patients to predict the numbers needed to plan an RCT. METHODS: Effectiveness estimates are derived from major observational studies (Risk of Paradoxical Embolism [RoPE] Study and Oxford Vascular Study, together referred to as the "RoPE-Ox" database) and all 6 major RCTs (Systematic, Collaborative, PFO Closure Evaluation [SCOPE] Consortium). To estimate stroke recurrence risk, observed outcomes were calculated for patients older than 60 years in the age-inclusive observational databases (n = 549). To estimate the reduction in the rate of recurrent stroke associated with PFO closure vs medical therapy based on the RoPE score and the presence of high-risk PFO features, a Cox proportional hazards regression model was developed on the RCT data in the SCOPE database (n = 3,740). These estimates were used to calculate sample sizes required for a future RCT. RESULTS: Five-year risk of stroke recurrence using Kaplan-Meier estimates was 13.7 (95% CI 10.5-17.9) overall, 14.9% (95% CI 10.2-21.6) in those with high-risk PFO features. Predicted relative reduction in the event rate with PFO closure was 12.9% overall, 48.8% in those with a high-risk PFO feature. Using these estimates, enrolling all older patients with cryptogenic stroke and PFO would require much larger samples than those used for prior PFO closure trials, but selectively enrolling patients with high-risk PFO features would require totals of 630 patients for 90% power and 471 patients for 80% power, with an average of 5 years of follow-up. DISCUSSION: Based on our projections, anticipated effect sizes in older patients with high-risk features make a trial in these subjects feasible. With lengthening life expectancy in almost all regions of the world, the utility of PFO closure in older adults is increasingly important to explore.


Assuntos
Estudos de Viabilidade , Forame Oval Patente , Seleção de Pacientes , Acidente Vascular Cerebral , Humanos , Forame Oval Patente/complicações , Forame Oval Patente/cirurgia , Idoso , Acidente Vascular Cerebral/etiologia , Masculino , Feminino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto , Recidiva , Resultado do Tratamento , Fatores Etários , Idoso de 80 Anos ou mais
3.
Card Electrophysiol Clin ; 16(2): 143-147, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749633

RESUMO

We present a complex case of cardiac implantable electronic device infection and extraction in the setting of bacteremia, large lead vegetation, and patent foramen ovale. Following a comprehensive preprocedural workup including transesophageal echocardiogram and computed tomography lead extraction protocol, in addition to the involvement of multiple subspecialties, an open chest approach to extraction was deemed a safer option for eradication of the patient's infection. Despite percutaneous techniques having evolved as the preferred extraction method during the last few decades, this case demonstrates the importance of a thorough evaluation at an experienced center to determine the need for open chest extraction.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Remoção de Dispositivo/métodos , Desfibriladores Implantáveis/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/diagnóstico por imagem , Marca-Passo Artificial/efeitos adversos , Masculino , Ecocardiografia Transesofagiana , Tomografia Computadorizada por Raios X , Idoso , Forame Oval Patente/cirurgia , Forame Oval Patente/diagnóstico por imagem , Feminino , Pessoa de Meia-Idade
4.
Medicina (Kaunas) ; 60(5)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38792900

RESUMO

Percutaneous closure of the patent foramen ovale (PFO) is generally regarded as a safe and effective procedure, indicated in patients with a prior PFO-associated stroke. While it is highly safe, rarely, it could be accompanied by a migration of the device, mainly caused by the interplay of a specific PFO morphology and inappropriate device sizing. Herein, we outline a seldom-observed complication of an unintentional detachment of the PFO closure device during implantation, leading to its migration into the abdominal aorta, and a unique management approach. Due to the inability to recapture the occluder with a snare, which is considered to be a mainstay of endovascular retrieval methods, two coronary guidewires were maneuvered through the mesh of the occluder and then captured with a snare proximally to the occluder. This innovative dual-wire-snare system was carefully pulled to the common femoral artery, a position deemed suitable for surgical extraction via arteriotomy, which was achieved successfully.


Assuntos
Forame Oval Patente , Dispositivo para Oclusão Septal , Humanos , Forame Oval Patente/cirurgia , Forame Oval Patente/complicações , Dispositivo para Oclusão Septal/efeitos adversos , Feminino , Embolia/etiologia , Pessoa de Meia-Idade
5.
G Ital Cardiol (Rome) ; 25(5): 295-299, 2024 May.
Artigo em Italiano | MEDLINE | ID: mdl-38639118

RESUMO

Patent foramen ovale (PFO) is a remnant of normal fetal anatomy which may persist into adulthood, mostly asymptomatic. In some adults, PFO may result in a potential for shunting venous thromboembolism to the arterial circulation; less frequently it can cause interatrial, right-to-left shunting of deoxygenated blood. The pathogenesis of several medical conditions is related to the presence of PFO. Some randomized clinical trials have shown evidence of benefit for device closure as compared with medical therapy in patients with cryptogenic stroke. The literature reported several cases of carbon dioxide embolism during general laparoscopic surgery and sometimes stroke after laparoscopic or neurosurgery but there are neither prospective studies addressing these issues, nor randomized clinical trials assessing the effectiveness of pharmacotherapy or interventional procedures at decreasing risk. The European position paper suggests routine monitoring in non-cardiac surgery of patients with a PFO and no actual indications for closure. This article aims to further stratify the risk of periprocedural stroke and paradoxical embolism in this category of patients.


Assuntos
Embolia Paradoxal , Forame Oval Patente , Acidente Vascular Cerebral , Adulto , Humanos , Forame Oval Patente/complicações , Forame Oval Patente/cirurgia , Estudos Prospectivos , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Prevenção Secundária/métodos , Embolia Paradoxal/etiologia , Embolia Paradoxal/prevenção & controle , Resultado do Tratamento
6.
Int J Cardiol ; 407: 132026, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38609055

RESUMO

OBJECTIVE: This study aimed to construct and validate a nomogram model that predicts the remission of migraine attacks by screening factors that affect the prognosis of migraine patients with patent foramen ovale (PFO) after closure. METHOD: Retrospective analysis was conducted in migraine patients with PFO who underwent PFO closure in the Department of Cardiology of Jiangsu Province Hospital from September 2020 to April 2023. Based on the Migraine Disability Assessment (MIDAS) scores from the 1-year follow-up after PFO closure, all patients who met the inclusion criteria were categorized into a remission group and a non-remission group. The primary efficacy endpoint was remission of migraine headache. After collecting clinical data, transcranial doppler sonography (TCD) results and MIDAS scores, LASSO (least absolute shrinkage and selection operator) regression and multivariable logistic regression analysis were used to filter variables predictive to migraine remission and construct the nomogram model. The Nomogram's accuracy and consistency were respectively assessed through Receiver Operating Characteristic (ROC) curves and calibration curves. Additionally, an analysis of decision curves (DCA) was conducted to evaluate the clinical utility of this newly developed model. RESULT: A total of 241 consecutive patients were included in the study. The remission group included 21 males and 93 females, with a median age of 39 (30.25,50) years. The non-remission group included 26 males and 101 females, with a median age of 35 (25.5,47.5) years. All Patients were randomly divided into a training cohort and a validation cohort. Multivariable logistic regression analysis showed that 5 independent predictors, including MIDAS before closure (p = 0.0002), mitigating factors (p = 0.0057), number of attacks/month (p = 0.0058), TCD (p = 0.0093) and Platelet Crit (PCT) (p = 0.0351), played a significant role in the prediction of remission of migraine patients with PFO after closure. Based on these independent predictors, the predictive nomogram model of migraine remission in PFO patients was constructed. The application of the nomogram in the training cohort exhibited good discrimination (area under the ROC curve was 0.7763[95% CI 0.7108-0.8418]), which was confirmed in the validation cohort (AUC was 0.704[95% CI 0.5533-0.8547]). The calibration curve showed that the nomogram model demonstrated good calibration performance. Additionally, the decision curve analysis indicated the clinical utility of the nomogram model. CONCLUSION: The construction of the nomogram model had a considerable predictive accuracy for migraine remission in patients after PFO closure, which may provide constructive guidance for clinical decision making.


Assuntos
Forame Oval Patente , Transtornos de Enxaqueca , Nomogramas , Humanos , Masculino , Feminino , Transtornos de Enxaqueca/diagnóstico , Transtornos de Enxaqueca/diagnóstico por imagem , Adulto , Estudos Retrospectivos , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/cirurgia , Forame Oval Patente/complicações , Pessoa de Meia-Idade , Indução de Remissão , Seguimentos
7.
J Cardiothorac Surg ; 19(1): 137, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38504353

RESUMO

BACKGROUND: Paradoxical embolism is a rare cause of acute arterial occlusion. This phenomenon arises when embolic material travels from the venous system crosses an abnormal shunt such as patent foramen ovale, atrial septal defects, ventricular septal defects, or pulmonary arteriovenous malformations, into the arterial system. Impending paradoxical embolism refers to the presence of an entrapped thrombus in the patent foramen ovale. CASE PRESENTATION: We report a case of a 68-year-old female patient who presented with an impending paradoxical embolism, alongside both concomitant pulmonary embolism and myocardial infarction with ST-segment elevation. Swiftly addressed through emergency cardiac surgery and systemic anticoagulation, the patient's condition was effectively treated. CONCLUSIONS: While the ideal treatment strategy for impending paradoxical embolism remains a topic of debate due to limited and inconclusive evidence, emergent open surgery should be contemplated in patients as it signifies a critical clinical emergency.


Assuntos
Embolia Paradoxal , Forame Oval Patente , Infarto do Miocárdio , Embolia Pulmonar , Feminino , Humanos , Idoso , Forame Oval Patente/complicações , Forame Oval Patente/cirurgia , Embolia Paradoxal/complicações , Embolia Paradoxal/cirurgia , Ecocardiografia Transesofagiana , Embolia Pulmonar/complicações , Embolia Pulmonar/cirurgia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/cirurgia
8.
J Invasive Cardiol ; 36(4)2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38412436

RESUMO

Atrial septal abnormalities are common congenital lesions that remain asymptomatic in many patients until adulthood. Adults with atrial septal defects (ASD) most commonly have ostium secundum ASD. Transcatheter closure has become increasingly popular in recent years as a successful alternative method to surgery for treating ASD and patent foramen ovale (PFO). The overall rate of ASD transcatheter closure device embolization has been reported to be less than 1%; however, retrieving the device via surgery or by trans-catheter route can be necessary. The current manuscript describes a systematic review of the techniques used to retrieve ASD closure devices, as well as their success rates, complications, and limitations. A comprehensive search was performed covering various databases including PubMed, MEDLINE, SCOPUS, Google Scholar, and Cochrane Library from inception until April 2022 for English-published case reports, case series, and experimental studies investigating the indications, safety, and limitations of ASD closure and ASD device retrieval by trans-catheter approaches. Finally, 20 studies were included in our review. Our findings showed that most of the studies used a single snare technique; of these, all but one reported 100% success. Double tool retrieval methods (snare plus snare, snare plus bioptome, or snare plus forceps) and the gooseneck snare technique yielded 100% success. One study that used the lasso technique reported unsuccessful retrieval and the need for surgical intervention. More recently, the novel "coronary wire trap technique" was introduced, which provides a simpler method for embolized device removal by trapping the device for retrieval using coronary wire.


Assuntos
Forame Oval Patente , Comunicação Interatrial , Dispositivo para Oclusão Septal , Adulto , Humanos , Forame Oval Patente/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/cirurgia , Cateteres Cardíacos
9.
J Invasive Cardiol ; 36(4)2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38412438

RESUMO

OBJECTIVES: Percutaneous closure of a patent foramen ovale (PFO) for the prevention of recurrent paradoxical thromboembolic events has been shown to be safe and effective in randomized controlled trials. However, it remains uncertain if differences in the structure and design of the occluder devices impact the outcomes. The aim of this study was to compare results of percutaneous PFO closure using 2 widely used double-disc occluders. METHODS: Consecutive patients who underwent percutaneous PFO closure with the Abbott Amplatzer occluder (APO) or the Occlutech Figulla-Flex-II occluder (OPO) at the Heart Center Lucerne between February 2017 and December 2022 were included in a registry. The primary endpoint was effective closure of the PFO, defined as a residual shunt grade 0 or 1, assessed by contrast echocardiogram at 6-month follow-up. Secondary endpoints included procedural efficacy/safety and major adverse cardiovascular events during the hospital stay and at 6-month follow-up. RESULTS: One hundred ninety-three consecutive patients (mean age 51.7 ± 12.5 years; 39% women; Risk of Paradoxical Embolism (RoPE) score = 7, IQR = 6-8) underwent percutaneous PFO closure with the APO (120 patients, 62.2%) or the OPO (73 patients, 37.8%). Main indications for closure were crypotogenic stroke in 168 patients (87.1%) and peripheral embolism in 13 patients (6.7%). At baseline, right-to-left shunt (RLS) greater than or equal to grade 2 was present in 189 patients (97.9%). Immediate procedural success was 99.5%. In 1 patient, an air embolism occurred during positioning of the APO occluder with transient chest pain and electrocardiogram changes, but without further sequelae to the patient. At 6-month follow-up, effective closure was achieved in 185 patients (95.8%; APO: 96.6% vs OPO: 94.5%, P = .30). Rates of atrial fibrillation and recurrent thromboembolic events were 4.2 and 0.5%, respectively. CONCLUSIONS: PFO closure is safe and effective when performed with either the self-expanding Abbott Amplatzer or Occlutech Figulla Flex II PFO occluder.


Assuntos
Forame Oval Patente , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Tromboembolia , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Forame Oval Patente/diagnóstico , Forame Oval Patente/cirurgia , Forame Oval Patente/complicações , Resultado do Tratamento , Ecocardiografia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Dispositivo para Oclusão Septal/efeitos adversos , Tromboembolia/etiologia , Cateterismo Cardíaco/métodos
10.
BMJ Case Rep ; 17(2)2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38331445

RESUMO

A South Asian male in his early 60s presented with acute-onset dyspnoea on postoperative day 4 after undergoing middle hepatic vein sacrificing partial liver resection for epithelioid angiomyolipoma. The patient's SpO2 on presentation was 65% in standing position which improved to 90% in left lateral decubitus. He was suspected of having platypnea-orthodeoxia syndrome (POS) which was confirmed on echocardiogram with microbubble contrast showing a large intracardiac right-to-left shunt. The patient was taken up for transcatheter closure of patent foramen ovale (PFO). A 30 mm Amplatzer PFO Occluder was deployed across the PFO which reduced the intracardiac shunt resulting in an improved arterial saturation as well as immediate relief of patient's symptoms. This case illustrates the importance of suspecting and recognising POS clinically as well as the efficacy of transcatheter closure of PFO in such cases leading to resolution of hypoxaemia in a short span of time.


Assuntos
Forame Oval Patente , Dispositivo para Oclusão Septal , Humanos , Masculino , Pessoa de Meia-Idade , Dispneia/diagnóstico , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/cirurgia , Hipóxia/etiologia , Hipóxia/terapia , Hipóxia/diagnóstico , Fígado , Síndrome de Platipneia Ortodeoxia
11.
J Med Econ ; 27(1): 337-343, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38373018

RESUMO

AIMS: Two randomized clinical trials, REDUCE and RESPECT, demonstrated that patent foramen ovale (PFO) closure in combination with antithrombotic therapy was more effective for the prevention of recurrent ischemic stroke compared with antithrombotic therapy alone. The aim of this study was to determine the relative efficacy and safety of the PFO closure devices used in REDUCE (HELEX and CARDIOFORM Septal Occluders) compared with the device used in RESPECT (Amplatzer PFO Occluder). METHODS: An unanchored matching-adjusted indirect comparison (MAIC) of the PFO closure arms of the REDUCE and RESPECT trials was performed using patient-level data from REDUCE weighted to match baseline characteristics from RESPECT. Comparisons of the following outcomes were made between the devices assessed in the trials: risk of recurrent ischemic stroke; recurrent ischemic stroke one year after randomization; any serious adverse event (SAE) related to the procedure or device; and atrial fibrillation or atrial flutter as an SAE related to the procedure or device. RESULTS: After conducting the MAIC, baseline characteristics were well-matched between the two trials. Compared to RESPECT, PFO closure using the devices from REDUCE resulted in a hazard ratio of 0.46 (95% confidence interval [CI] 0.15-1.43; p = 0.17) for the risk of recurrent stroke. For the recurrence of stroke after one year, SAE related to the procedure or device, and atrial fibrillation or atrial flutter as SAE related to the procedure or device, the MAIC resulted in a rate difference of -0.68 (95%CI -2.06 to 0.70; p = .34), -1.29 (95%CI -3.82 to 1.25; p = .32), and -0.19 (95%CI -1.16 to 0.78; p = .71), respectively. These findings were consistent across scenario analyses. CONCLUSIONS: This MAIC analysis found no statistically significant differences in efficacy and safety outcomes between PFO closure with the HELEX and CARDIOFORM Septal Occluders versus the Amplatzer PFO Occluder, as used in the REDUCE and RESPECT trials.


The individual efficacy and safety of medical devices used for patent foramen ovale (PFO) closure in patients with stroke of unknown origin has been demonstrated in two independent trials: REDUCE (using the HELEX Septal Occluder and the CARDIOFORM Septal Occluder) and RESPECT (using the Amplatzer PFO Occluder). In the absence of a direct head-to-head trial for these devices, indirect treatment comparisons offer an alternative to assess their relative efficacy and safety. This study used a matching-adjusted indirect comparison to demonstrate that there were no significant differences between the devices used for PFO closure in the REDUCE and RESPECT trials in terms of safety outcomes.


Assuntos
Fibrilação Atrial , Flutter Atrial , Forame Oval Patente , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Fibrinolíticos , Forame Oval Patente/complicações , Forame Oval Patente/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
12.
Circ Cardiovasc Qual Outcomes ; 17(1): e010200, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38189127

RESUMO

BACKGROUND: Following regulatory approval, medical devices may be used "off-label." Patent foramen ovale (PFO) closure is indicated to reduce recurrent stroke but has been proposed for other indications, including migraine, transient ischemic attack, and diving decompression illness. We sought to evaluate PFO closure rates and indications relative to the timing of regulatory approval and publication of key randomized trials. METHODS: We performed a retrospective cohort study using the OptumLabs Data Warehouse of US commercial insurance enrollees from 2006 to 2019. We quantified PFO closure among individuals with ≥2 years of preprocedure coverage to establish indications, classified hierarchically as stroke/systemic embolism, migraine, transient ischemia attack, or other. RESULTS: We identified 5315 patients undergoing PFO closure (51.8% female, 29.2%≥60 years old), which increased from 4.75 per 100 000 person-years in 2006 to 6.60 per 100 000 person-years in 2019. Patients aged ≥60 years accounted for 29.2% of closures. Procedure volumes corresponded weakly with supportive clinical publications and device approval. Among patients with PFO closure, 58.6% underwent closure for stroke/systemic embolism, 10.2% for transient ischemia attack, 8.8% for migraine, and 22.4% for other indications; 17.6% of patients had atrial fibrillation at baseline; and 11.9% developed atrial fibrillation postprocedure. Those aged ≥60 years and male were less likely to undergo closure for migraine than stroke/systemic embolism. CONCLUSIONS: From 2006 to 2019, PFO closure use was consistently low and corresponded weakly with clinical trial publications and regulatory status. Nearly half of patients underwent PFO closure for indications unapproved by the Food and Drug Administration. Regulators and payers should coordinate mechanisms to promote utilization for approved indications to ensure patient safety and should facilitate clinical trials for other possible indications.


Assuntos
Fibrilação Atrial , Embolia , Forame Oval Patente , Ataque Isquêmico Transitório , Transtornos de Enxaqueca , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Forame Oval Patente/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Cateterismo Cardíaco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/prevenção & controle , Prevenção Secundária/métodos , Isquemia
14.
PLoS One ; 19(1): e0291299, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38166018

RESUMO

BACKGROUND: Percutaneous closure of a patent foramen ovale (PFO) or the left atrial appendage (LAA) are controversial procedures to prevent stroke but often used in clinical practice. We assessed the regional variation of these interventions and explored potential determinants of such a variation. METHODS: We conducted a population-based analysis using patient discharge data from all Swiss hospitals from 2013-2018. We derived hospital service areas (HSAs) using patient flows for PFO and LAA closure. We calculated age-standardized mean procedure rates and variation indices (extremal quotient [EQ] and systematic component of variation [SCV]). SCV values >5.4 indicate a high and >10 a very high variation. Because the evidence on the efficacy of PFO closure may differ in patients aged <60 years and ≥60 years, age-stratified analyses were performed. We assessed the influence of potential determinants of variation using multilevel regression models with incremental adjustment for demographics, cultural/socioeconomic, health, and supply factors. RESULTS: Overall, 2574 PFO and 2081 LAA closures from 10 HSAs were analyzed. The fully adjusted PFO and LAA closure rates varied from 3 to 8 and from 1 to 9 procedures per 100,000 persons per year across HSAs, respectively. The regional variation was high with respect to overall PFO closures (EQ 3.0, SCV 8.3) and very high in patients aged ≥60 years (EQ 4.0, SCV 12.3). The variation in LAA closures was very high (EQ 16.2, SCV 32.1). In multivariate analysis, women had a 28% lower PFO and a 59% lower LAA closure rate than men. French/Italian language areas had a 63% lower LAA closure rate than Swiss German speaking regions and areas with a higher proportion of privately insured patients had a 86% higher LAA closure rate. After full adjustment, 44.2% of the variance in PFO closure and 30.3% in LAA closure remained unexplained. CONCLUSIONS: We found a high to very high regional variation in PFO closure and LAA closure rates within Switzerland. Several factors, including sex, language area, and insurance status, were associated with procedure rates. Overall, 30-45% of the regional procedure variation remained unexplained and most probably represents differing physician practices.


Assuntos
Forame Oval Patente , AVC Isquêmico , Acidente Vascular Cerebral , Masculino , Humanos , Feminino , AVC Isquêmico/complicações , Suíça/epidemiologia , Análise de Pequenas Áreas , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Forame Oval Patente/cirurgia , Forame Oval Patente/complicações , Resultado do Tratamento , Cateterismo Cardíaco/métodos
15.
Cardiovasc Interv Ther ; 39(2): 200-206, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38265606

RESUMO

Transcatheter closure of patent foramen ovale (PFO) is an effective strategy for preventing recurrence of paradoxical embolism. However, PFO closure is often associated with residual shunt, which is a risk of recurrent stroke. This study aimed to evaluate the relationship between the anatomical features of PFO and residual shunt. The degree of residual shunt and its relationship with the anatomical features of PFO were evaluated in 106 patients who underwent PFO closure at our institution between March 2011 and January 2022 and in whom contrast transthoracic echocardiography was performed 1 year later. The mean PFO tunnel length was 9.3 ± 3.6 mm and the mean PFO height was 3.2 ± 2.2 mm. Atrial septal aneurysm (ASA) was found in 37 patients. After PFO closure, residual shunt was observed in 28 patients (grade 1, n = 8; grade 2, n = 16; grade 3, n = 3; grade 4, n = 1). Univariate logistic analysis identified ASA to be associated with residual shunt (odds ratio 2.78, 95% confidence interval 1.14 to 6.79; p = 0.024). There was no association of residual shunt with the size of the PFO, the length of PFO tunnel, or the size of the device used for closure. Two of four patients with a large residual shunt of grade 3 or grade 4 were found to have device size mismatch. Residual shunt after PFO closure was observed in a quarter of patients and was related to the presence of ASA. A few patients had a large residual shunt due to the device size mismatch.


Assuntos
Forame Oval Patente , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Humanos , Forame Oval Patente/cirurgia , Forame Oval Patente/complicações , Ecocardiografia , Resultado do Tratamento , Cateterismo Cardíaco
18.
Int Heart J ; 65(1): 146-151, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38296568

RESUMO

A 36-year-old woman suffered from an embolic stroke of an undetermined source documented by magnetic resonance imaging with residual right arm weakness. She underwent percutaneous patent foramen ovale (PFO) closure with an 18/25 mm device in another center. One year later, the patient suffered from a transient ischemic attack with dysarthria. She asked for a second opinion at our institution and a contrast-transthoracic (cTTE) /transesophageal echocardiography showed a large residual right-to-left shunt (RLS) through a still patent tunnel after PFO closure. Written informed consent for a redo procedure was obtained from the patient. A catheter-based closure of the residual shunt was therefore planned under local anesthesia and rotational intracardiac echo monitoring. A second equally sized disc (18/18 mm) device was successfully implanted without complications. The patient was discharged home the following day in good clinical condition. Dual antiplatelet therapy was recommended for the first 2 months and then single antiplatelet therapy up to 6 months. At the 6-month follow-up, the cTTE color Doppler showed the stable position of the two nitinol double-disc devices and the c-transcranial Doppler confirmed the abolition of the residual RLS.


Assuntos
Forame Oval Patente , Ataque Isquêmico Transitório , AVC Isquêmico , Adulto , Feminino , Humanos , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Forame Oval Patente/cirurgia , Ataque Isquêmico Transitório/epidemiologia , AVC Isquêmico/epidemiologia , Resultado do Tratamento
19.
Eur J Intern Med ; 120: 25-28, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38072687

RESUMO

Atrial septal defects (ASD) and Patent foramen ovale (PFO) represent the most common congenital heart diseases (CHD) adulthood. These two clinical entities, having different embryological origin, as well as clinical manifestations, clinical course and treatment must be carefully distinguished. Right heart failure and pulmonary hypertension are considered the major determinants of morbidity and mortality in ASD. Conversely, new pathophysiology concepts have been raised in the management of PFO as left atrium cardiopathy. New diagnostic tools, including cardiac magnetic resonance and intracardiac echocardiography have joint transthoracic and transesophageal echocardiography in the diagnostic definition of both ASD and PFO as well as in guiding their percutaneous closure. Moreover, several innovations have been developed in the field of percutaneous ASD and PFO closure devices including new evidence supporting the safety and efficacy of device-based closure. Aim of the present review is to present review we provided and update overview on ASD and PFO, focusing on the novel concepts regarding their pathophysiological and therapeutic aspects.


Assuntos
Forame Oval Patente , Comunicação Interatrial , Dispositivo para Oclusão Septal , Humanos , Adulto , Resultado do Tratamento , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/cirurgia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Ecocardiografia Transesofagiana , Átrios do Coração/diagnóstico por imagem , Cateterismo Cardíaco
20.
Hellenic J Cardiol ; 75: 21-25, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37127207

RESUMO

BACKGROUND: The Cocoon patent foramen ovale (PFO) occluder is a new device especially designed for transcatheter closure of PFO. This occluder has some distinctive structural modifications aimed at reducing the risk of major complications of transcatheter PFO closure. In this report we present our initial experience to evaluate the efficacy and safety of the Cocoon PFO occluder in 253 patients who underwent transcatheter PFO closure. METHODS: The study cohort included 253 patients (median age 45 years) with embolic stroke of undetermined source who underwent attempted transcatheter closure of PFO for secondary prevention of paradoxical embolism. Patients were enrolled retrospectively from five sites in Greece and one in Romania between December 2016 and January 2021, and the median follow-up period was 28 months (range 12-48 months). Clinical and laboratory data from each participating center were sent to an electronic registry for evaluation and statistical analysis. RESULTS: The Cocoon PFO occluder was permanently implanted in all patients. At 6 months, complete occlusion of PFO was observed in 251/253 (99.2%) patients. Three (1.2%) patients had a trivial residual shunt. Thrombus formation on the device, which was successfully treated with recombinant tissue plasminogen activator infusion, was observed in one (0.4%) patient. No other complications occurred. During a median follow-up period of 28 months, 3 (1.2%) patients, aged 64-67 years, developed new onset paroxysmal atrial fibrillation. No neurologic events, cardiac erosions, allergic reactions to nickel, or thrombus formation occurred. CONCLUSION: The Cocoon PFO occluder is an effective and safe device that adds to our armamentarium for transcatheter closure of PFO.


Assuntos
Forame Oval Patente , Dispositivo para Oclusão Septal , Trombose , Humanos , Pessoa de Meia-Idade , Forame Oval Patente/complicações , Forame Oval Patente/cirurgia , Estudos Retrospectivos , Ativador de Plasminogênio Tecidual , Próteses e Implantes , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Dispositivo para Oclusão Septal/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA