Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 426
Filtrar
1.
Nursing ; 54(1): 16-21, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38126981

RESUMO

ABSTRACT: This article provides a step-by-step guide for nurses to interpret arterial blood gas (ABG) results, focusing on five key components: SaO2, PaO2, pH, PaCO2, and HCO3-. It explains how to assess a patient's oxygenation status, compensation levels, and determine if there is an acid-base disturbance and if that disturbance is respiratory or metabolic.


Assuntos
Gases , Testes Hematológicos , Humanos , Gases/sangue
2.
Sci Rep ; 11(1): 10415, 2021 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-34112816

RESUMO

Volatile organic compounds (VOCs) released through skin (transcutaneous gas) has been increasing in importance for the continuous and real-time assessment of diseases or metabolisms. For stable monitoring of transcutaneous gas, finding a body part with little interference on the measurement is essential. In this study, we have investigated the possibility of external ears for stable and real-time measurement of ethanol vapour by developing a monitoring system that consisted with an over-ear gas collection cell and a biochemical gas sensor (bio-sniffer). The high sensitivity with the broad dynamic range (26 ppb-554 ppm), the high selectivity to ethanol, and the capability of the continuous measurement of the monitoring system uncovered three important characteristics of external ear-derived ethanol with alcohol intake for the first time: there is little interference from sweat glands to a sensor signal at the external ear; similar temporal change in ethanol concentration to that of breath with delayed peak time (avg. 13 min); relatively high concentration of ethanol relative to other parts of a body (external ear-derived ethanol:breath ethanol = 1:590). These features indicated the suitability of external ears for non-invasive monitoring of blood VOCs.


Assuntos
Técnicas Biossensoriais , Monitorização Transcutânea dos Gases Sanguíneos , Gases/sangue , Compostos Orgânicos Voláteis/sangue , Álcool Desidrogenase/química , Consumo de Bebidas Alcoólicas , Testes Respiratórios , Orelha Externa/química , Enzimas Imobilizadas/química , Etanol/química , Humanos
4.
Ann Lab Med ; 40(6): 448-456, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32539300

RESUMO

BACKGROUND: The storage temperature and time of blood gas samples collected in syringes constitute preanalytical variables that could affect blood gas or lactate concentration measurement results. We analyzed the effect of storage temperature and time delay on arterial or venous blood gas stability related to pH, partial pressure of carbon dioxide (pCO2) and oxygen (pO2), hemoglobin oxygen saturation (sO2), and lactate concentration. METHODS: In total, 1,200 arterial and venous blood sample syringes were analyzed within 10 minutes of collection. The samples were divided into different groups to determine parameter stability at 25, 4-8, and 0-3.9°C and at different storage times, 60, 45, 30, and 15 minutes. Independent sample groups were used for each analysis. Percentage deviations were calculated and compared with acceptance stability limits (1.65× coefficient of variation). Additionally, sample group sub analysis was performed to determine whether stability was concentration-dependent for each parameter. RESULTS: The pH was stable over all storage times at 4-8 and 0-3.9°C and up to 30 minutes at 25°C. pCO2 was stable at ≤60 minutes at all temperatures. pO2 was stable for 45 minutes at 0-3.9°C, and sO2 was stable for 15 minutes at 25°C and for ≤60 minutes at 0-3.9°C. Lactate concentration was stable for 45 minutes at 0-3.9°C. Subanalysis showed that stability was concentration-dependent. CONCLUSIONS: The strictest storage temperature and time criteria (0-3.9°C, 45 minutes) should be adopted for measuring pH, pCO2, pO2, sO2, and lactate concentration in blood gas syringes.


Assuntos
Coleta de Amostras Sanguíneas/métodos , Gases/sangue , Hemoglobinas/química , Ácido Láctico/química , Oxigênio/química , Coleta de Amostras Sanguíneas/instrumentação , Hemoglobinas/metabolismo , Humanos , Concentração de Íons de Hidrogênio , Pressão Parcial , Temperatura , Fatores de Tempo
5.
Proc Natl Acad Sci U S A ; 117(18): 10067-10078, 2020 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-32321831

RESUMO

Disorders of oxygen transport are commonly attributed to inadequate carrying capacity (anemia) but may also relate to inefficient gas exchange by red blood cells (RBCs), a process that is poorly characterized yet assumed to be rapid. Without direct measurements of gas exchange at the single-cell level, the barriers to O2 transport and their relationship with hematological disorders remain ill defined. We developed a method to track the flow of O2 in individual RBCs by combining ultrarapid solution switching (to manipulate gas tension) with single-cell O2 saturation fluorescence microscopy. O2 unloading from RBCs was considerably slower than previously estimated in acellular hemoglobin solutions, indicating the presence of diffusional barriers in intact cells. Rate-limiting diffusion across cytoplasm was demonstrated by osmotically induced changes to hemoglobin concentration (i.e., diffusive tortuosity) and cell size (i.e., diffusion pathlength) and by comparing wild-type cells with hemoglobin H (HbH) thalassemia (shorter pathlength and reduced tortuosity) and hereditary spherocytosis (HS; expanded pathlength). Analysis of the distribution of O2 unloading rates in HS RBCs identified a subpopulation of spherocytes with greatly impaired gas exchange. Tortuosity imposed by hemoglobin was verified by demonstrating restricted diffusivity of CO2, an acidic gas, from the dissipative spread of photolytically uncaged H+ ions across cytoplasm. Our findings indicate that cytoplasmic diffusion, determined by pathlength and tortuosity, is a major barrier to efficient gas handling by RBCs. Consequently, changes in RBC shape and hemoglobin concentration, which are common manifestations of hematological disorders, can have hitherto unrecognized and clinically significant implications on gas exchange.


Assuntos
Transporte Biológico/genética , Eritrócitos/metabolismo , Gases/sangue , Oxigênio/sangue , Adulto , Idoso , Dióxido de Carbono/sangue , Citoplasma/metabolismo , Feminino , Voluntários Saudáveis , Hemoglobinas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Célula Única
6.
Sci Rep ; 10(1): 333, 2020 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-31941991

RESUMO

Neonatal sepsis is characterised by dysregulated immune responses. Lipid mediators (LMs) are involved in the regulation of inflammation. Human recombinant thrombomodulin (rhTM), an anticoagulant, has anti-inflammatory effects and might be useful for sepsis treatment. A stock caecal slurry (CS) solution was prepared from adult caeca. To induce sepsis, 1.5 mg/g of CS was administered intraperitoneally to 4 d-old wild-type FVB mouse pups. Saline (Veh-CS) or rhTM (3 or 10 mg/kg; rhTM3-CS or rhTM10-CS) was administered subcutaneously 6 h prior to sepsis induction, and liver LM profiles at 3 and 6 h post-sepsis induction and survival up to 7 days were examined. Mortality was significantly lower (47%) in the rhTM3-CS group and significantly higher (100%) in the rhTM10-CS group, compared with the Veh-CS group (79%, p < 0.05). Eleven LMs (12-HEPE, EPA, 14-HDHA, DHA, PD1, PGD2, 15d-PGJ2, 12S-HHT, lipoxin B4, 12-HETE, AA) were significantly increased at 3 h, and five LMs (5-HEPE, 15-HEPE, 18-HEPE, 17-HDHA, PD1) were significantly increased at 6 h post-sepsis induction. Increased EPA, DHA, 12S-HHT, lipoxin B4, and AA were significantly suppressed by rhTM pre-treatment. rhTM was protective against neonatal sepsis. This protective effect might be mediated via LM modulation. Further post-sepsis studies are needed to determine clinical plausibility.


Assuntos
Sepse/tratamento farmacológico , Trombomodulina/uso terapêutico , Animais , Animais Recém-Nascidos , Ácidos Araquidônicos/análise , Cromatografia Líquida de Alta Pressão , Dinoprostona/análise , Modelos Animais de Doenças , Ácidos Docosa-Hexaenoicos/análise , Gases/sangue , Humanos , Estimativa de Kaplan-Meier , Camundongos , Substâncias Protetoras/uso terapêutico , Proteínas Recombinantes/biossíntese , Proteínas Recombinantes/isolamento & purificação , Proteínas Recombinantes/uso terapêutico , Sepse/mortalidade , Sepse/patologia , Índice de Gravidade de Doença , Espectrometria de Massas em Tandem , Trombomodulina/genética , Trombomodulina/metabolismo
7.
PLoS One ; 15(1): e0227700, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31971994

RESUMO

In vertebrates, the embryonic environment is known to affect the development and the health of individuals. In broiler chickens, the thermal-manipulation (TM) of eggs during the incubation period was shown to improve heat tolerance at slaughter age (35 days of age) in association with several modifications at the molecular, metabolic and physiological levels. However, little is known about the Japanese quail (Coturnix japonica), a closely related avian species widely used as a laboratory animal model and farmed for its meat and eggs. Here we developed and characterized a TM procedure (39.5°C and 65% relative humidity, 12 h/d, from days 0 to 13 of incubation) in quails by analyzing its short and long-term effects on zootechnical, physiological and metabolic parameters. Heat-tolerance was tested by a heat challenge (36°C for 7h) at 35 days of age. TM significantly reduced the hatching rate of the animals and increased mortality during the first four weeks of life. At hatching, TM animals were heavier than controls, but lighter at 25 days of age for both sexes. Thirty-five days after hatching, TM decreased the surface temperature of the shank in females, suggesting a modulation of the blood flow to maintain the internal temperature. TM also increased blood partial pressure and oxygen saturation percentage at 35 days of age in females, suggesting a long-term modulation of the respiration physiology. Quails physiologically responded to the heat challenge, with a modification of several hematologic and metabolic parameters, including an increase in plasma corticosterone concentration. Several physiological parameters such as beak surface temperature and blood sodium concentration revealed that TM birds responded differently to the heat challenge compared to controls. Altogether, this first comprehensive characterization of TM in Japanese quail showed durable effects that may affect the response of TM quails to heat.


Assuntos
Regulação da Temperatura Corporal/fisiologia , Coturnix/embriologia , Animais , Antioxidantes/metabolismo , Embrião de Galinha , Galinhas/crescimento & desenvolvimento , Galinhas/fisiologia , Coturnix/crescimento & desenvolvimento , Coturnix/fisiologia , Desenvolvimento Embrionário/fisiologia , Feminino , Gases/sangue , Temperatura Alta , Masculino , Termotolerância/fisiologia
8.
Physiol Rep ; 7(24): e14317, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31876064

RESUMO

We found that lung surfactant leaks into the bloodstream, settling on the luminal aspect of blood vessels to create active hydrophobic spots (AHS). Nanobubbles formed by dissolved gas at these AHS are most probably the precursors of gas micronuclei and decompression bubbles. Sheep blood vessels stretched on microscope slides, and exposed under saline to hyperbaric pressure, were photographed following decompression. Photographs of an AHS from a pulmonary vein, containing large numbers of bubbles, were selected in 1-min sequences over a period of 7 min, starting 18 min after decompression from 1,013 kPa. This showed bubble detachment, coalescence and expansion, as well as competition for dissolved gas between bubbles. There was greater expansion of peripheral than of central bubbles. We suggest that the dynamics of decompression bubbles on the surface of the blood vessel may be the closest approximation to true decompression physiology, and as such can be used to assess and calibrate models of decompression bubbles. We further discuss the implications for bubble size in the venous circulation.


Assuntos
Doença da Descompressão/sangue , Veias Pulmonares/fisiopatologia , Animais , Doença da Descompressão/fisiopatologia , Gases/sangue , Surfactantes Pulmonares/sangue , Ovinos
9.
Biosensors (Basel) ; 9(1)2019 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-30889834

RESUMO

Accurate and cost-effective integrated sensor systems for continuous monitoring of pH and blood gases continue to be in high demand. The capacity of ion-selective and Gas-sensitive field effect transistors (FETs) to serve as low-power sensors for accurate continuous monitoring of pH and blood gases is evaluated in the amperometric or current mode of operation. A stand-alone current-mode topology is employed in which a constant bias is applied to the gate with the drain current serving as the measuring signal. Compared with voltage-mode operation (e.g., in the feedback mode in ion-selective FETs), current-mode topologies offer the advantages of small size and low power consumption. However, the ion-selective FET (ISFET) and the Gas-sensitive FET (GasFET) exhibit a similar drift behavior, imposing a serious limitation on the accuracy of these sensors for continuous monitoring applications irrespective of the mode of operation. Given the slow temporal variation associated with the drift characteristics in both devices, a common post-processing technique that involves monitoring the variation of the drain current over short intervals of time can potentially allow extraction of the measuring signal in presence of drift in both sensor types. Furthermore, in the amperometric mode the static sensitivity of a FET-based sensor, given by the product of the FET transconductance and the sensitivity of the device threshold voltage to the measurand concentration, can be increased by adjusting the device design parameters. Increasing the sensitivity, while of interest in its own right, also enhances the accuracy of the proposed method. Rigorous analytical validation of the method is presented for GasFET operation in the amperometric mode. Moreover, the correction algorithm is verified experimentally using a Si3N4-gate ISFET operating in the amperometric mode to monitor pH variations ranging from 3.5 to 10.


Assuntos
Algoritmos , Técnicas Biossensoriais/métodos , Ácidos/sangue , Técnicas Biossensoriais/normas , Gasometria/métodos , Gasometria/normas , Gases/sangue , Humanos , Transistores Eletrônicos/normas
10.
Clin Exp Pharmacol Physiol ; 46(3): 216-225, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30575111

RESUMO

Early, non-clinical studies support the use of hydroxocobalamin to treat sepsis-induced hypotension, but there is no translational, large animal model. The objective of this study was to compare survival in a sepsis model where large swine had endotoxaemia induced with lipopolysaccharide (LPS) and were treated with intravenous hydroxocobalamin (HOC), noradrenaline (NA), or saline. Thirty swine (45-55 kg) were anaesthetized, intubated, and instrumented with continuous femoral and pulmonary artery pressure monitoring. Hypotension, predefined as 50% of baseline, was induced with LPS. Animals then received HOC, NA, or saline and monitored for 3 hours. The main outcome was survival to the conclusion of the study. Using a power of 80% and an alpha of 0.05, 10 animals were used per group. Secondary outcomes included: mean arterial pressure (MAP), systemic vascular resistance (SVR) and cardiac output (CO) along with several markers of sepsis. No differences were detected between groups at baseline or after hypotension. The survival distributions of the three groups were significantly different with more HOC animals surviving (10/10) compared with NA (8/10) or Saline (5/10) (log-rank P < 0.03). MAP was found to be higher in both the HOC and NA groups and HOC achieved the highest SVR. In this large animal, translational study of an endotoxaemic model of sepsis, hydroxocobalamin improved survival when compared with saline.


Assuntos
Hidroxocobalamina/farmacologia , Hipotensão/tratamento farmacológico , Lipopolissacarídeos/efeitos adversos , Norepinefrina/farmacologia , Solução Salina/farmacologia , Administração Intravenosa , Animais , Biomarcadores/sangue , Modelos Animais de Doenças , Feminino , Gases/sangue , Hemodinâmica/efeitos dos fármacos , Hidroxocobalamina/administração & dosagem , Hidroxocobalamina/uso terapêutico , Hipotensão/complicações , Hipotensão/metabolismo , Hipotensão/fisiopatologia , Norepinefrina/administração & dosagem , Norepinefrina/uso terapêutico , Solução Salina/administração & dosagem , Solução Salina/uso terapêutico , Choque Séptico/complicações , Suínos
11.
Undersea Hyperb Med ; 45(3): 287-295, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30028915

RESUMO

INTRODUCTION: Decompression sickness (DCS) is manifested by the quantity and location of bubbles in body tissues after reduction in ambient pressures. Models have been formulated to explain why bubbles form, but none provide satisfactory explanations as to why the findings of DCS occur as they do. This first of a three-part series explains why and at what sites DCS occurs. MATERIALS AND METHODS: Over a 50-year span and 500 cases of DCS we have managed, it has become apparent that almost all "unexplained" DCS (i.e., cases with no obvious explanation as to how/why they occurred) have physiological explanations. The vagaries of the physiology of tissue perfusion and the physics of gradients as a cause of autochthonous bubble formation were analyzed. FINDINGS: Perfusion is highly variable, with so-called "fast" tissues (i.e., tissues with a rapid rate of saturation) requiring a constant blood supply, "intermediate" tissues requiring a blood supply proportional to needs, and "slow" tissues having minimal perfusion requirements. The 5-liter blood volume in a vascular system with greater than a 20-liter capacity requires careful regulation. Disruptions in the regulation and/or overwhelming gradients explain why DCS occurs. CONCLUSIONS: Our Gradient-Perfusion Model provides an explanation as to why disordering events account for almost all cases of unexplained DCS. We propose that this latter term be discarded and "disordering events" be sought for DCS cases that have no obvious explanations.


Assuntos
Doença da Descompressão/etiologia , Modelos Cardiovasculares , Fluxo Sanguíneo Regional/fisiologia , Volume Sanguíneo/fisiologia , Doença da Descompressão/fisiopatologia , Gases/sangue , Humanos , Pulmão/fisiologia , Especificidade de Órgãos/fisiologia
12.
Artif Organs ; 41(9): 865-874, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28597590

RESUMO

The objective of this study was to compare the hemodynamic performances and gaseous microemboli (GME) handling ability of two pediatric oxygenators in a simulated pediatric cardiopulmonary bypass (CPB) model and the importance of adding an arterial filter in the circuit. The circuit consisted of a Braile Infant oxygenator or a Maquet Quadrox-I Pediatric oxygenator without integrated arterial filter (parallel arrangement), 1/4 in. ID tubing A-V loop, and a 12-Fr arterial cannula, primed with lactated Ringer's solution and packed red blood cells. Trials were conducted at flow rates ranging from 500 to 2000 mL/min (500 mL/min increment) at 35°C and 28°C. Real-time pressure and flow data were recorded using a custom-based data acquisition system. For GME testing, 5 cc of air was manually injected into the venous line. GME were recorded using the Emboli Detection and Classification Quantifier (EDAC) System. An additional experiment using a separate arterial filter was conducted. There was no difference in the mean circuit pressure, pressure drop, total hemodynamic energy level, and energy loss between the two oxygenators. The venous line pressures were higher in the Braile than in the Quadrox group during all trials (P <0.01). GME count and volume at pre-/post oxygenator and pre-cannula sites in the Quadrox were lower than the Braile group at high flow rates (P < 0.05). In the additional experiment, an arterial filter captured a significant number of microemboli at all flow rates. The Braile Infant oxygenator has a matched hemodynamic characteristic with the Quadrox-i Pediatric oxygenator. The Quadrox-i has a better GME handling ability compared with the Braile Infant oxygenator. Regardless of type of oxygenator an additional arterial filter decreases the number of GME.


Assuntos
Ponte Cardiopulmonar/efeitos adversos , Embolia Aérea/prevenção & controle , Modelos Cardiovasculares , Oxigenadores de Membrana/efeitos adversos , Artérias , Criança , Embolia Aérea/etiologia , Desenho de Equipamento , Gases/sangue , Hemodinâmica , Humanos , Técnicas In Vitro , Pesquisa Interdisciplinar , Pressão
13.
An Acad Bras Cienc ; 89(1 Suppl 0): 445-456, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28492734

RESUMO

This study investigated the anesthetic potential of the essential oil (EO) of Aloysia polystachya in juveniles of dusky grouper (Epinephelus marginatus). Fish were exposed to different concentrations of EO of A. polystachya to evaluate time of induction and recovery from anesthesia. In the second experiment, fish were divided into four groups: control, ethanol and 50 or 300 µL L-1 EO of A. polystachya, and each group was submitted to induction for 3.5 min and recovery for 5 or 10 min. The blood gases and glucose levels showed alterations as a function of the recovery times, but Na+ and K+ levels did not show any alteration. In conclusion, the EO from leaves of A. polystachya is an effective anesthetic for dusky grouper, because anesthesia was reached within the recommended time at EO concentrations of 300 and 400 µL L-1. However, most evaluated blood parameters showed compensatory responses due to EO exposure.


Assuntos
Anestésicos/farmacologia , Biomarcadores/sangue , Peixes-Gato/sangue , Óleos Voláteis/farmacologia , Óleos de Plantas/farmacologia , Verbenaceae/química , Animais , Bicarbonatos/sangue , Gases/sangue , Glucose/análise , Hematócrito , Hemoglobinas/análise , Concentração de Íons de Hidrogênio , Metais Alcalinos/sangue , Folhas de Planta/química
14.
An. acad. bras. ciênc ; 89(1,supl): 445-456, May. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-886648

RESUMO

ABSTRACT This study investigated the anesthetic potential of the essential oil (EO) of Aloysia polystachya in juveniles of dusky grouper (Epinephelus marginatus). Fish were exposed to different concentrations of EO of A. polystachya to evaluate time of induction and recovery from anesthesia. In the second experiment, fish were divided into four groups: control, ethanol and 50 or 300 µL L−1 EO of A. polystachya, and each group was submitted to induction for 3.5 min and recovery for 5 or 10 min. The blood gases and glucose levels showed alterations as a function of the recovery times, but Na+ and K+ levels did not show any alteration. In conclusion, the EO from leaves of A. polystachya is an effective anesthetic for dusky grouper, because anesthesia was reached within the recommended time at EO concentrations of 300 and 400 µL L−1. However, most evaluated blood parameters showed compensatory responses due to EO exposure.


Assuntos
Animais , Peixes-Gato/sangue , Óleos de Plantas/farmacologia , Óleos Voláteis/farmacologia , Biomarcadores/sangue , Verbenaceae/química , Anestésicos/farmacologia , Bicarbonatos/sangue , Hemoglobinas/análise , Folhas de Planta/química , Gases/sangue , Glucose/análise , Hematócrito , Concentração de Íons de Hidrogênio , Metais Alcalinos/sangue
15.
Am J Physiol Regul Integr Comp Physiol ; 311(5): R797-R810, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27488891

RESUMO

Countercurrent systems have evolved in a variety of biological systems that allow transfer of heat, gases, and solutes. For example, in the renal medulla, the countercurrent arrangement of vascular and tubular elements facilitates the trapping of urea and other solutes in the inner medulla, which in turn enables the formation of concentrated urine. Arteries and veins in the cortex are also arranged in a countercurrent fashion, as are descending and ascending vasa recta in the medulla. For countercurrent diffusion to occur, barriers to diffusion must be small. This appears to be characteristic of larger vessels in the renal cortex. There must also be gradients in the concentration of molecules between afferent and efferent vessels, with the transport of molecules possible in either direction. Such gradients exist for oxygen in both the cortex and medulla, but there is little evidence that large gradients exist for other molecules such as carbon dioxide, nitric oxide, superoxide, hydrogen sulfide, and ammonia. There is some experimental evidence for arterial-to-venous (AV) oxygen shunting. Mathematical models also provide evidence for oxygen shunting in both the cortex and medulla. However, the quantitative significance of AV oxygen shunting remains a matter of controversy. Thus, whereas the countercurrent arrangement of vasa recta in the medulla appears to have evolved as a consequence of the evolution of Henle's loop, the evolutionary significance of the intimate countercurrent arrangement of blood vessels in the renal cortex remains an enigma.


Assuntos
Evolução Biológica , Gases/sangue , Rim/irrigação sanguínea , Rim/fisiologia , Circulação Renal/genética , Ureia/sangue , Animais , Transporte Biológico Ativo/genética , Humanos , Artéria Renal , Veias Renais
16.
J Exp Biol ; 219(Pt 13): 2003-14, 2016 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-27091862

RESUMO

Ranid frogs in northern latitudes survive winter at cold temperatures in aquatic habitats often completely covered by ice. Cold-submerged frogs survive aerobically for several months relying exclusively on cutaneous gas exchange while maintaining temperature-specific acid-base balance. Depending on the overwintering hibernaculum, frogs in northern latitudes could spend several months without access to air, the need to breathe or the chemosensory drive to use neuromuscular processes that regulate and enable pulmonary ventilation. Therefore, we performed experiments to determine whether aspects of the respiratory control system of bullfrogs, Lithobates catesbeianus, are maintained or suppressed following minimal use of air breathing in overwintering environments. Based on the necessity for control of lung ventilation in early spring, we hypothesized that critical components of the respiratory control system of bullfrogs would be functional following simulated overwintering. We found that bullfrogs recently removed from simulated overwintering environments exhibited similar resting ventilation when assessed at 24°C compared with warm-acclimated control bullfrogs. Additionally, ventilation met resting metabolic and, presumably, acid-base regulation requirements, indicating preservation of basal respiratory function despite prolonged disuse in the cold. Recently emerged bullfrogs underwent similar increases in ventilation during acute oxygen lack (aerial hypoxia) compared with warm-acclimated frogs; however, CO2-related hyperventilation was significantly blunted following overwintering. Overcoming challenges to gas exchange during overwintering have garnered attention in ectothermic vertebrates, but this study uncovers robust and labile aspects of the respiratory control system at a time point correlating with early spring following minimal to no use of lung breathing in cold-aquatic overwintering habitats.


Assuntos
Metabolismo Basal , Oxigênio/metabolismo , Ventilação Pulmonar , Rana catesbeiana/fisiologia , Animais , Gasometria , Temperatura Baixa , Feminino , Gases/sangue , Homeostase , Distribuição Aleatória , Respiração , Estações do Ano
17.
Ann Biol Clin (Paris) ; 74(1): 79-92, 2016.
Artigo em Francês | MEDLINE | ID: mdl-26744105

RESUMO

The purpose of this article is to describe the setting up of 15 blood gas analyzers GEM(®) Premier™ 4000 (IL) at Montpellier hospital. This experience includes analytical characterization (within and between run coefficient of variation) using GSE and GHE IL controls, correlation of 35 samples with a routinely used laboratory blood gas analyzer (Cobas b221, Roche(®)). We shall also develop the training, the habilitation and its follow-up for the user staff (450 people) of the different hospital's units in the aim of the accreditation.


Assuntos
Equipamentos Médicos Duráveis , Gases/análise , Gases/sangue , Laboratórios Hospitalares , Sistemas Automatizados de Assistência Junto ao Leito , Automação Laboratorial , Gasometria/instrumentação , Gasometria/normas , Calibragem , Equipamentos Médicos Duráveis/normas , Seguimentos , França , Hospitais Universitários/organização & administração , Hospitais Universitários/normas , Humanos , Laboratórios Hospitalares/organização & administração , Laboratórios Hospitalares/normas , Pessoal de Laboratório Médico/educação , Pessoal de Laboratório Médico/normas , Sistemas Automatizados de Assistência Junto ao Leito/organização & administração , Sistemas Automatizados de Assistência Junto ao Leito/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Recursos Humanos
18.
PLoS One ; 10(8): e0134387, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26247476

RESUMO

BACKGROUND: The analysis of heart rate variability (HRV) has been shown as a promising non-invasive technique for assessing the cardiac autonomic modulation in trauma. The aim of this study was to evaluate HRV during hemorrhagic shock and fluid resuscitation, comparing to traditional hemodynamic and metabolic parameters. METHODS: Twenty anesthetized and mechanically ventilated pigs were submitted to hemorrhagic shock (60% of estimated blood volume) and evaluated for 60 minutes without fluid replacement. Surviving animals were treated with Ringer solution and evaluated for an additional period of 180 minutes. HRV metrics (time and frequency domain) as well as hemodynamic and metabolic parameters were evaluated in survivors and non-survivors animals. RESULTS: Seven of the 20 animals died during hemorrhage and initial fluid resuscitation. All animals presented an increase in time-domain HRV measures during haemorrhage and fluid resuscitation restored baseline values. Although not significantly, normalized low-frequency and LF/HF ratio decreased during early stages of haemorrhage, recovering baseline values later during hemorrhagic shock, and increased after fluid resuscitation. Non-surviving animals presented significantly lower mean arterial pressure (43±7 vs 57±9 mmHg, P<0.05) and cardiac index (1.7±0.2 vs 2.6±0.5 L/min/m2, P<0.05), and higher levels of plasma lactate (7.2±2.4 vs 3.7±1.4 mmol/L, P<0.05), base excess (-6.8±3.3 vs -2.3±2.8 mmol/L, P<0.05) and potassium (5.3±0.6 vs 4.2±0.3 mmol/L, P<0.05) at 30 minutes after hemorrhagic shock compared with surviving animals. CONCLUSIONS: The HRV increased early during hemorrhage but none of the evaluated HRV metrics was able to discriminate survivors from non-survivors during hemorrhagic shock. Moreover, metabolic and hemodynamic variables were more reliable to reflect hemorrhagic shock severity than HRV metrics.


Assuntos
Frequência Cardíaca/fisiologia , Ressuscitação , Choque Hemorrágico/fisiopatologia , Animais , Modelos Animais de Doenças , Eletrocardiografia , Eletrólitos/sangue , Gases/sangue , Hemodinâmica , Choque Hemorrágico/metabolismo , Suínos
19.
Respir Physiol Neurobiol ; 216: 1-8, 2015 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-26003848

RESUMO

Bubbles nucleate and develop after decompression at active spots on the luminal aspect of ovine large blood vessels. Series of bubbles were shown to detach from the active spot with a mean diameter of 0.7-1.0mm in calm conditions. The effect of mechanical disturbance (striking the bowl containing the vessel or tangential flow) was studied on ovine blood vessels stretched on microscope slides and photographed after hyperbaric exposure. Diameter on detachment after a heavy blow to the bowl was 0.87 ± 0.43 mm (mean ± SD), no different from bubbles which detached without striking the bowl (0.86 ± 0.28 mm). Bubble diameter on detachment during pulsatile tangential flow at 234 cm/min, 0.99 ± 0.36 mm, was not smaller than that seen in the same blood vessels in calm conditions (0.81 ± 0.34 mm). The active spots were stained for lipids, proving their hydrophobicity. The most abundant active spots, which produced only a few bubbles, did not stain for lipids thereafter. The possibility that phospholipids were removed along with detached bubbles may correlate with acclimation to diving. The finding of bubble production at the active spots matches observed phenomena in divers: variable sensitivity to decompression, acclimation to diving, the effect of elevated gas load on increased bubble formation, a higher bubble score in the second dive on the same day, and unexplained neurological symptoms after decompression. Large bubbles released from the arterial circulation give serious cause for concern.


Assuntos
Vasos Sanguíneos/fisiologia , Descompressão , Gases/sangue , Animais , Circulação Sanguínea , Descompressão/métodos , Oxigenoterapia Hiperbárica , Técnicas In Vitro , Estimulação Física/métodos , Fluxo Pulsátil/fisiologia , Ovinos , Estatísticas não Paramétricas
20.
Surg Today ; 45(2): 156-61, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24880671

RESUMO

PURPOSE: To evaluate the risk factors for bowel necrosis in adult patients with hepatic portal venous gas (HPVG). METHODS: This retrospective study comprised 33 adult patients treated for HPVG between August, 2008 and December, 2011. The patients were divided into a necrotic group (n = 14) and a non-necrotic group (n = 19). We analyzed the clinical demographics, laboratory data, multi-detector computed tomography findings, treatments, and outcomes in each group. RESULTS: Abdominal pain, peritoneal signs, systolic blood pressure, aspartate aminotransferase, alanine aminotransferase, lactate dehydrogenase (LDH), small intestinal dilatation, poor enhancement of the bowel wall, and intestinal pneumatosis were all significantly associated with bowel necrosis. Moreover, there were significantly more operative cases and deaths in the necrotic group. Multivariate analysis revealed that systolic BP (p = 0.048), LDH (p = 0.022), and intestinal pneumatosis (p = 0.038) were independent risk factors for bowel necrosis. Thus, we created new diagnostic criteria for bowel necrosis based on these three factors, the sensitivity, specificity, and accuracy of which were 100, 78.9, and 87.9 %, respectively. CONCLUSIONS: This study demonstrates new and important findings to evaluate the risk factors for bowel necrosis. Using our diagnostic criteria, the indications for emergency laparotomy can be established more accurately.


Assuntos
Gases/sangue , Enteropatias/etiologia , Enteropatias/patologia , Intestino Delgado/patologia , Veia Porta , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Necrose , Pneumatose Cistoide Intestinal , Veia Porta/diagnóstico por imagem , Análise de Regressão , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA