Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.985
Filtrar
1.
PLoS One ; 19(5): e0303849, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38768185

RESUMO

PURPOSE: Random noise-moving images (noises) can make glaucoma patients with no subjective symptoms aware of visual field abnormalities. To explore this concept, we developed a noise using computer graphics (CG) and investigated the difference in the subjective perception of visual field abnormalities between CG and conventional analog noises. METHODS: We enrolled individuals with glaucoma (205 eyes), preperimetric glaucoma (PPG; 19 eyes), and normal eyes (35 eyes). For a CG noise, a series of still images was made by randomly selecting five monochromatic tones on 2-mm square dots, and these images were drawn at 60 frames per second (fps) to create a noise-moving image. The participants were asked to describe their perceived shadows on a paper. The results were categorized as follows based on the pattern deviation probability map of the Humphrey field analyzer (HFA): "agreement," "partial agreement," "disagreement," and "no response." The glaucoma stage was classified into four stages, from M1 to M4, based on the HFA's mean deviation. RESULT: The detection rates (agreement and partial agreement) were 80.5% and 65.4% for the CG and analog noises, respectively, with CG noise showing a significantly higher detection rate in all glaucoma eyes (P < 0.001). The detection rates tended to increase as the glaucoma stage progressed, and in Stage M3, these were 93.9% and 78.8% for the CG and analog noises, respectively. The PPG eyes did not exhibit subjective abnormalities for both noises. The specificity values were 97.1% and 100% for the CG and analog noises, respectively. CONCLUSION: The CG noise is more effective than the analog noise in evaluating the subjective perception of visual field abnormalities in patients with glaucoma.


Assuntos
Gráficos por Computador , Glaucoma , Campos Visuais , Humanos , Glaucoma/fisiopatologia , Campos Visuais/fisiologia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Testes de Campo Visual/métodos , Adulto , Percepção Visual/fisiologia
2.
Transl Vis Sci Technol ; 13(5): 10, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38743410

RESUMO

Purpose: To compare perimetric outcomes of an iPad perimetry app (Melbourne Rapid Fields [MRF]) with those of the Humphrey Field Analyser (HFA) testing children with glaucoma. Methods: Sixteen children diagnosed and treated for glaucoma were recruited to evaluate their perimetric performance over two visits. At each visit, they undertook visual field assessment using the MRF application as well as the HFA. The HFA test was part of their usual clinical work up and a clinical assistant judged which test format (24-2 SITA standard or SITA fast) might be suited to the testing of that child. The primary outcome measure was the association and repeatability of mean deviation (MD) for the MRF and HFA tests, by way of regression, intraclass correlation coefficient and Bland-Altman analysis. Secondary measures were comparisons of pattern deviation indices, test times as well as an indication of participant test preference. Summary data show means ± standard deviation. Results: The age for our cohort was 7 to 15 years of age (mean, 10.0 ± 2.4 years of age). The MRF MD was in close concordance to HFA MD with an intraclass correlation coefficient of 0.91 (95% confidence interval, 0.82-0.95). Bland-Altman analysis found little bias (-0.6 dB) and a 95% coefficient of repeatability of 2.1 dB in eyes having a normal HFA MD. In eyes with glaucomatous visual field defects the 95% coefficient of repeatability at retest was much larger for both the MRF (10.5 dB) as well as for the HFA (10.0 dB). Average MRF test times (5.6 ± 1.2 minutes) were similar to SITA Fast (5.4 ± 1.9 minutes) with both being significantly faster than SITA standard (8.6 ± 1.4 minutes; P < 0.001). All children chose testing with the MRF as their preference. Conclusions: MRF correlated strongly with HFA and was preferred by the children over the HFA. MRF is suitable for perimetric evaluation of children with glaucoma. Translational Relevance: This study finds that an iPad based visual field test can be used with children having glaucoma to yield outcomes similar to SITA-fast. Children indicate a preference for such testing.


Assuntos
Computadores de Mão , Glaucoma , Testes de Campo Visual , Campos Visuais , Humanos , Criança , Campos Visuais/fisiologia , Testes de Campo Visual/métodos , Testes de Campo Visual/instrumentação , Masculino , Feminino , Adolescente , Glaucoma/diagnóstico , Glaucoma/fisiopatologia , Reprodutibilidade dos Testes
3.
Transl Vis Sci Technol ; 13(5): 9, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38743409

RESUMO

Purpose: To assess the diagnostic performance and structure-function association of retinal retardance (RR), a customized metric measured by a prototype polarization-sensitive optical coherence tomography (PS-OCT), across various stages of glaucoma. Methods: This cross-sectional pilot study analyzed 170 eyes from 49 healthy individuals and 68 patients with glaucoma. The patients underwent PS-OCT imaging and conventional spectral-domain optical coherence tomography (SD-OCT), as well as visual field (VF) tests. Parameters including RR and retinal nerve fiber layer thickness (RNFLT) were extracted from identical circumpapillary regions of the fundus. Glaucomatous eyes were categorized into early, moderate, or severe stages based on VF mean deviation (MD). The diagnostic performance of RR and RNFLT in discriminating glaucoma from controls was assessed using receiver operating characteristic (ROC) curves. Correlations among VF-MD, RR, and RNFLT were evaluated and compared within different groups of disease severity. Results: The diagnostic performance of both RR and RNFLT was comparable for glaucoma detection (RR AUC = 0.98, RNFLT AUC = 0.97; P = 0.553). RR showed better structure-function association with VF-MD than RNFLT (RR VF-MD = 0.68, RNFLT VF-MD = 0.58; z = 1.99; P = 0.047) in glaucoma cases, especially in severe glaucoma, where the correlation between VF-MD and RR (r = 0.73) was significantly stronger than with RNFLT (r = 0.43, z = 1.96, P = 0.050). In eyes with early and moderate glaucoma, the structure-function association was similar when using RNFLT and RR. Conclusions: RR and RNFLT have similar performance in glaucoma diagnosis. However, in patients with glaucoma especially severe glaucoma, RR showed a stronger correlation with VF test results. Further research is needed to validate RR as an indicator for severe glaucoma evaluation and to explore the benefits of using PS-OCT in clinical practice. Translational Relevance: We demonstrated that PS-OCT has the potential to evaluate the status of RNFL structural damage in eyes with severe glaucoma, which is currently challenging in clinics.


Assuntos
Glaucoma , Fibras Nervosas , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Campos Visuais , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Masculino , Feminino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Projetos Piloto , Campos Visuais/fisiologia , Glaucoma/fisiopatologia , Glaucoma/diagnóstico por imagem , Idoso , Células Ganglionares da Retina/patologia , Curva ROC , Testes de Campo Visual/métodos , Adulto , Pressão Intraocular/fisiologia
4.
Invest Ophthalmol Vis Sci ; 65(5): 34, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38776117

RESUMO

Purpose: A thin cornea is a potent risk factor for glaucoma. The underlying mechanisms remain unexplained. It has been postulated that central corneal thickness (CCT) may be a surrogate for biomechanical parameters of the posterior eye. In this study, we aimed to explore correlations of biomechanical responses between the cornea and the optic nerve head (ONH) and the peripapillary sclera (PPS) to elevated intraocular pressure (IOP), the primary risk factor of glaucoma. Methods: Inflation tests were performed in nine pairs of human donor globes. One eye of each pair was randomly assigned for cornea or posterior eye inflation. IOP was raised from 5 to 30 millimeters of mercury (mmHg) at 0.5 mmHg steps in the whole globe and the cornea or the ONH/PPS was imaged using a 50 MHz ultrasound probe. Correlation-based ultrasound speckle tracking was used to calculate tissue displacements and strains. Associations of radial, tangential, and shear strains at 30 mmHg between the cornea and the ONH or PPS were evaluated. Results: Corneal shear strain was significantly correlated with ONH shear strain (R = 0.857, P = 0.003) and PPS shear strain (R = 0.724, P = 0.028). CCT was not correlated with any strains in the cornea, ONH, or PPS. Conclusions: Our results suggested that an eye that experiences a larger shear strain in the cornea would likely experience a larger shear strain in its ONH and PPS at IOP elevations. The strong correlation between the cornea's and the ONH's shear response to IOP provides new insights and suggests a plausible explanation of the cornea's connection to glaucoma risk.


Assuntos
Córnea , Pressão Intraocular , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagem , Córnea/diagnóstico por imagem , Córnea/fisiologia , Pressão Intraocular/fisiologia , Fenômenos Biomecânicos/fisiologia , Idoso , Pessoa de Meia-Idade , Esclera/fisiologia , Esclera/diagnóstico por imagem , Masculino , Feminino , Glaucoma/fisiopatologia , Idoso de 80 Anos ou mais , Doadores de Tecidos , Adulto
5.
Invest Ophthalmol Vis Sci ; 65(5): 32, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38771570

RESUMO

Purpose: To evaluate VEGF-C-induced lymphoproliferation in conjunction with 5-fluorouracil (5-FU) antimetabolite treatment in a rabbit glaucoma filtration surgery (GFS) model. Methods: Thirty-two rabbits underwent GFS and were assigned to four groups (n = 8 each) defined by subconjunctival drug treatment: (a) VEGF-C combined with 5-FU, (b) 5-FU, (c) VEGF-C, (d) and control. Bleb survival, bleb measurements, and IOP were evaluated over 30 days. At the end, histology and anterior segment OCT were performed on some eyes. mRNA was isolated from the remaining eyes for RT-PCR evaluation of vessel-specific markers (lymphatics, podoplanin and LYVE-1; and blood vessels, CD31). Results: Qualitatively and quantitatively, VEGF-C combined with 5-FU resulted in blebs which were posteriorly longer and wider than the other conditions: vs. 5-FU (P = 0.043 for longer, P = 0.046 for wider), vs. VEGF-C (P < 0.001, P < 0.001) and vs. control (P < 0.001, P < 0.001). After 30 days, the VEGF-C combined with 5-FU condition resulted in longer bleb survival compared with 5-FU (P = 0.025), VEGF-C (P < 0.001), and control (P < 0.001). Only the VEGF-C combined with 5-FU condition showed a negative correlation between IOP and time that was statistically significant (r = -0.533; P = 0.034). Anterior segment OCT and histology demonstrated larger blebs for the VEGF-C combined with 5-FU condition. Only conditions including VEGF-C led to increased expression of lymphatic markers (LYVE-1, P < 0.001-0.008 and podoplanin, P = 0.002-0.011). Expression of CD31 was not different between the groups (P = 0.978). Conclusions: Adding VEGF-C lymphoproliferation to standard antimetabolite treatment improved rabbit GFS success and may suggest a future strategy to improve human GFSs.


Assuntos
Modelos Animais de Doenças , Fluoruracila , Glaucoma , Pressão Intraocular , Trabeculectomia , Fator C de Crescimento do Endotélio Vascular , Animais , Coelhos , Fluoruracila/uso terapêutico , Fluoruracila/farmacologia , Glaucoma/cirurgia , Glaucoma/fisiopatologia , Glaucoma/tratamento farmacológico , Fator C de Crescimento do Endotélio Vascular/metabolismo , Trabeculectomia/métodos , Pressão Intraocular/fisiologia , Antimetabólitos/farmacologia , Antimetabólitos/uso terapêutico , Tomografia de Coerência Óptica , Túnica Conjuntiva , RNA Mensageiro/genética
6.
Vestn Oftalmol ; 140(2. Vyp. 2): 43-50, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739130

RESUMO

PURPOSE: This study investigates the influence of peripheral corneal thickness (PCT) and its curvature on tonometry readings. MATERIAL AND METHODS: The study included 49 patients (49 eyes) who were indicated for glaucoma surgery. Using bidirectional applanation tonometry, the following parameters were obtained: IOPcc, IOPg - intraocular pressure (IOP) corrected for corneal compensation, taken as the most reliable indicator; IOP converted to Goldmann measurement, taken as the result of applanation tonometry, ΔIOP (IOPcc-IOPg), CH and CRF (corneal hysteresis and corneal resistance factor). During corneal topography, the corneal thickness was studied in the center, PCT at 1.5; 2, 3, 4 and 5 mm from the center in four meridians, as well as ΔPCT (PCT 3 mm - PCT 1.5 mm), the curvature of the anterior and posterior surfaces of the cornea and the depth of the anterior chamber. Aberrometry was used to obtain refractometry data and the curvature of the anterior surface of the cornea. The influence of the studied parameters on ΔIOP was evaluated. RESULTS: ΔIOP correlated with CRF (r= -0.652), CH (r= -0.873), central corneal thickness (r= -0.293), PCT at all distances except 5 mm (r= -0.297; -0.287; -0.302; -0.303), with the strong and weak meridians of the anterior surface of the cornea (r=0.328; r=0.315), with the strong and weak meridians of the posterior surface, as well as the average curvature of the posterior surface (r=0.307; r=0.332; r=0.328). After step-by-step selection of the above parameters for creating a linear regression model for ΔIOP calculation, CH, CRF and PCT1.5mm remained in the model. The model describes ΔIOP with high accuracy (R2=0.974). CONCLUSION: Biomechanical parameters of the cornea are the leading factor of applanation tonometry error. Individual linear dimensions of the cornea (thickness, curvature) have a lesser effect.


Assuntos
Córnea , Topografia da Córnea , Glaucoma , Pressão Intraocular , Tonometria Ocular , Humanos , Tonometria Ocular/métodos , Córnea/diagnóstico por imagem , Pressão Intraocular/fisiologia , Masculino , Feminino , Pessoa de Meia-Idade , Topografia da Córnea/métodos , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Reprodutibilidade dos Testes , Idoso , Adulto
7.
Vestn Oftalmol ; 140(2. Vyp. 2): 34-42, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739129

RESUMO

PURPOSE: This study analyzes changes in light sensitivity in each test point of the visual field in patients with different stages of glaucoma. MATERIAL AND METHODS: The data of a prospective analytical case-control study were analyzed. All patients underwent assessment of retinal light sensitivity and its variability in 54 points corresponding to the 24-2 program. Mean light sensitivity values were calculated in each point. Intergroup analysis was performed to evaluate changes in light sensitivity in each point. RESULTS: The range of light sensitivity decrease in the early glaucoma group compared to the control group was from 1.5 to 3.6 dB. The range of light sensitivity decrease in the moderate glaucoma group compared to the control group was from 2.1 to 11.5 dB, and compared to the early glaucoma group - from -0.9 to 7.9 dB. The most frequent decrease in light sensitivity was detected in the nasal sector and along the horizontal line in the upper half of the visual field. This trend persisted within the central 10 degrees of the visual field. The range of light sensitivity decrease in the advanced glaucoma group compared to the control group was from 14.1 to 28.0 dB, and compared to the early glaucoma group - from 11.35 to 26.08 dB, compared to the moderate glaucoma group - from 9.1 to 23.5 dB. The most frequent and severe decrease in light sensitivity was detected in the paracentral zone in the lower half of the visual field. CONCLUSION: The study analyzed the trends in the development of glaucoma from the early to the advanced stage. The most frequent and severe defect in light sensitivity in cases of verified advanced glaucoma was found in the lower half of the visual field. Points No. 32, 33 and 40 can be indicated as the area of interest in assessing the progression of glaucoma, as they were found to have the most profound changes in light sensitivity as glaucoma progressed.


Assuntos
Progressão da Doença , Glaucoma , Testes de Campo Visual , Campos Visuais , Humanos , Campos Visuais/fisiologia , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Testes de Campo Visual/métodos , Estudos Prospectivos , Idoso , Estudos de Casos e Controles , Luz
8.
Vestn Oftalmol ; 140(2. Vyp. 2): 116-122, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739140

RESUMO

PURPOSE: This study assesses the light sensitivity and its variability in each point of the visual field in patients without glaucoma and with different stages of glaucoma. MATERIAL AND METHODS: The data of a prospective analytical case-control study involving 500 patients were analyzed. The initial examination of all patients was performed using basic ophthalmological methods, including static perimetry. Retinal light sensitivity and its variability were assessed in 54 points corresponding to the Humphrey 24-2 program. Mean deviation and pattern standard deviation of light sensitivity were calculated for each point. RESULTS: The lowest light sensitivity values in patients with moderate glaucoma were found in the periphery of the nasal sector, at point No. 27 - 14.4 dB, and at points No. 24-26 along the horizontal axis from the nasal side - from 17.7 to 22.7 dB. The maximum variability of light sensitivity was found in the nasal sector on both sides of the horizontal line - from 10.7 to 11.5 dB. The average light sensitivity above the horizontal axis in patients with advanced glaucoma was 10.8 dB, which is 2 dB higher than in the lower half of the visual field - 8.8 dB. The highest light sensitivity values were found at points No. 24 - 17.7 dB and No. 31 - 16.78 dB, the lowest - at point No. 32 - 4.5 dB. The average variability values of light sensitivity in the upper half of the visual field were 9.6 dB, which is 1 dB less than in the lower half of the visual field - 10.6 dB. CONCLUSION: According to our data, points No. 32 and No. 40 are of particular interest in the diagnostic plan. In these loci, the highest light sensitivity values were determined in early and moderate glaucoma. However, the values in these points decrease significantly in advanced glaucoma. It can be assumed that changes in light sensitivity in these loci at the early stages of glaucoma may be a predictor of glaucoma progression.


Assuntos
Glaucoma , Retina , Testes de Campo Visual , Campos Visuais , Humanos , Campos Visuais/fisiologia , Testes de Campo Visual/métodos , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Pessoa de Meia-Idade , Masculino , Feminino , Retina/fisiopatologia , Estudos Prospectivos , Adulto , Luz , Idoso , Limiar Sensorial/fisiologia , Estudos de Casos e Controles , Reprodutibilidade dos Testes
9.
Acta Biomater ; 180: 206-229, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38641184

RESUMO

This study presents a 3D in vitro cell culture model, meticulously 3D printed to replicate the conventional aqueous outflow pathway anatomical structure, facilitating the study of trabecular meshwork (TM) cellular responses under glaucomatous conditions. Glaucoma affects TM cell functionality, leading to extracellular matrix (ECM) stiffening, enhanced cell-ECM adhesion, and obstructed aqueous humor outflow. Our model, reconstructed from polyacrylamide gel with elastic moduli of 1.5 and 21.7 kPa, is based on serial block-face scanning electron microscopy images of the outflow pathway. It allows for quantifying 3D, depth-dependent, dynamic traction forces exerted by both normal and glaucomatous TM cells within an active fluid-structure interaction (FSI) environment. In our experimental design, we designed two scenarios: a control group with TM cells observed over 20 hours without flow (static setting), focusing on intrinsic cellular contractile forces, and a second scenario incorporating active FSI to evaluate its impact on traction forces (dynamic setting). Our observations revealed that active FSI results in higher traction forces (normal: 1.83-fold and glaucoma: 2.24-fold) and shear strains (normal: 1.81-fold and glaucoma: 2.41-fold), with stiffer substrates amplifying this effect. Glaucomatous cells consistently exhibited larger forces than normal cells. Increasing gel stiffness led to enhanced stress fiber formation in TM cells, particularly in glaucomatous cells. Exposure to active FSI dramatically altered actin organization in both normal and glaucomatous TM cells, particularly affecting cortical actin stress fiber arrangement. This model while preliminary offers a new method in understanding TM cell biomechanics and ECM stiffening in glaucoma, highlighting the importance of FSI in these processes. STATEMENT OF SIGNIFICANCE: This pioneering project presents an advanced 3D in vitro model, meticulously replicating the human trabecular meshwork's anatomy for glaucoma research. It enables precise quantification of cellular forces in a dynamic fluid-structure interaction, a leap forward from existing 2D models. This advancement promises significant insights into trabecular meshwork cell biomechanics and the stiffening of the extracellular matrix in glaucoma, offering potential pathways for innovative treatments. This research is positioned at the forefront of ocular disease study, with implications that extend to broader biomedical applications.


Assuntos
Glaucoma , Malha Trabecular , Malha Trabecular/patologia , Humanos , Glaucoma/patologia , Glaucoma/fisiopatologia , Matriz Extracelular/metabolismo , Técnicas de Cultura de Células em Três Dimensões , Células Cultivadas , Fenômenos Biomecânicos
10.
Jpn J Ophthalmol ; 68(3): 183-191, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38598144

RESUMO

PURPOSE: To assess the impact of glaucoma on perceiving three-dimensional (3D) shapes based on monocular depth cues. STUDY DESIGN: Clinical observational study. METHODS: Twenty glaucoma patients, subjected to binocular visual-field sensitivity (binocular-VFS) tests using a Humphrey Visual Field Analyzer, and 20 age-matched healthy volunteers, underwent two tasks: identifying the nearest vertex of a 3D shape using monocular shading (3D-SfS), texture (3D-SfT), or motion (3D-SfM) cues, and distinguishing elementary one-dimensional (1D) features of these cues. The association of the visual-field index (VFI) of binocular-VFS with 3D shape perception in glaucoma patients was also examined. RESULTS: Glaucoma patients demonstrated reduced accuracy in distinguishing 1D luminance brightness and a larger "error-in-depth" between the perceived and actual depths for 3D-SfM and 3D-SfS compared to healthy volunteers. Six glaucoma patients with a 100% VFI for binocular-VFS exhibited a similar error-in-depth to the other fourteen glaucoma patients; they had a larger error-in-depth for 3D-SfM compared to healthy volunteers. No correlation between the error-in-depth values and the VFI values of binocular-VFS was observed. CONCLUSIONS: The 3D shape perception in glaucoma patients varies based on the depth cue's characteristics. Impaired 1D discrimination and larger thresholds for 3D-SfM in glaucoma patients with a 100% VFI for binocular-VFS indicate more pronounced perceptual deficits of lower-level elementary features for 3D-SfS and higher-level visual processing of 3D shapes for 3D-SfM. The effects of the location and degree of binocular visual-field defects on 3D shape perception remain to be elucidated. Our research provides insights into the 3D shape extraction mechanism in glaucoma.


Assuntos
Sinais (Psicologia) , Percepção de Profundidade , Glaucoma , Visão Binocular , Visão Monocular , Campos Visuais , Humanos , Masculino , Feminino , Percepção de Profundidade/fisiologia , Visão Binocular/fisiologia , Campos Visuais/fisiologia , Pessoa de Meia-Idade , Idoso , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Visão Monocular/fisiologia , Testes de Campo Visual , Pressão Intraocular/fisiologia , Percepção de Forma/fisiologia , Adulto
14.
Turk J Ophthalmol ; 54(2): 83-89, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38645613

RESUMO

Objectives: To review the current literature related to the correlation between translaminar pressure difference (TLPD) and glaucoma. Materials and Methods: In this article, we conducted a literature review using MEDLINE via PubMed, Cochrane Eyes and Vision, and Google Scholar from 01/01/2010 to 31/12/2022. Search terms included "glaucoma", "intraocular pressure", "translaminar cribrosa pressure gradient/difference", "intracranial pressure", and "cerebrospinal fluid pressure". Of 471 results, 8 articles were selected for the meta-analysis. Results: Our meta-analysis demonstrated significantly higher intraocular pressure, lower cerebrospinal fluid pressure (CSFp), and greater TLPD in high-tension and normal-tension glaucoma groups compared to healthy groups. Conclusion: The differences in CSFp and TLPD between glaucoma and healthy people detected in current studies suggests a potential relationship between TLPD and glaucoma.


Assuntos
Pressão Intraocular , Doenças do Nervo Óptico , Humanos , Pressão Intraocular/fisiologia , Doenças do Nervo Óptico/diagnóstico , Doenças do Nervo Óptico/etiologia , Doenças do Nervo Óptico/fisiopatologia , Pressão do Líquido Cefalorraquidiano/fisiologia , Glaucoma/fisiopatologia , Tonometria Ocular , Glaucoma de Baixa Tensão/fisiopatologia , Glaucoma de Baixa Tensão/diagnóstico
15.
Int Ophthalmol ; 44(1): 196, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662242

RESUMO

PURPOSE: Some patients refrained from seeking an ophthalmologist due to the anxiety and morbidity associated with the coronavirus disease (COVID-19) pandemic. We investigated progressive visual field defects in patients with glaucoma who refrained from ophthalmological examinations. METHODS: This was a retrospective study. We analyzed data from 886 patients with glaucoma who visited Inouye Eye Hospital in June 2022 and were followed-up prior to January 2020. We examined the number of times patients canceled visits between January 2020 and May 2022 due to coronavirus concerns. We assessed the mean deviation (MD) values of the Humphrey Visual Field Assessment (HFA) program 30-2 SITA Standard values after visit interruptions for worsening beyond the MD values predicted by the MD slope. Factors influencing this difference were analyzed using logistic regression analysis. RESULTS: The study included 374 men and 512 women. The mean age was 68.7 ± 12.0 years. Visit interruptions occurred in 146 patients (16.5%), with 95 (65.1%) rescheduling once, 27 (18.5%) twice, and 24 (16.4%) three or more times. Among 90 patients who underwent HFA regularly, 50 (55.6%) experienced worse-than-expected MD values and 12 (13.3%) deteriorated by 2 dB or more. Longer interruptions and high intraocular pressure before interruption worsened the MD values by 2 dB or more. CONCLUSION: Patients with glaucoma with visit interruptions due to the pandemic should be monitored for the progression of visual field impairment.


Assuntos
COVID-19 , Progressão da Doença , Glaucoma , SARS-CoV-2 , Campos Visuais , Humanos , COVID-19/epidemiologia , Masculino , Feminino , Estudos Retrospectivos , Idoso , Glaucoma/epidemiologia , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Campos Visuais/fisiologia , Pessoa de Meia-Idade , Pandemias , Testes de Campo Visual , Pressão Intraocular/fisiologia , Idoso de 80 Anos ou mais
16.
Int Ophthalmol ; 44(1): 200, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662305

RESUMO

PURPOSE: To analyse real-world outcomes in Asian eyes of iStent inject, a second-generation trabecular micro-bypass stent, combined with phacoemulsification. METHODS: This is a multi-centre, observational study of glaucomatous Asian eyes that have undergone iStent inject implantation combined with cataract surgery. Patient data were extracted from the Fight Glaucoma Blindness! Registry. Outcome measures included those of IOP reduction, glaucoma medication reduction, and adverse events including the need for secondary surgery. RESULTS: 123 eyes of 86 patients with a mean age of 68.4 ± 9.3 years underwent iStent inject implantation with phacoemulsification. At baseline, the mean ± SD preoperative intraocular pressure (IOP) was 16.0 ± 4.4 mmHg, and the mean preoperative number of topical glaucoma medications was 1.9 ± 1.4. At 12 months 30.8% of eyes demonstrated a reduction in IOP greater than 20%, the mean IOP reduction was 12.5% with an additional reduction of 0.7 glaucoma medications. 40% of eyes were using no medications at 12 months compared to 16.3% preoperatively. 8.2% of eyes required a subsequent procedure within the 12-month follow-up window. CONCLUSION: iStent inject implantation combined with phacoemulsification in Asian eyes showed a reduction of IOP and glaucoma medication use in a real-world clinical setting. The safety profile of the device is good with minimal adverse outcomes, however, a subset of patients required secondary procedures within the 12 month follow up.


Assuntos
Pressão Intraocular , Sistema de Registros , Humanos , Masculino , Feminino , Idoso , Pressão Intraocular/fisiologia , Pessoa de Meia-Idade , Implantes para Drenagem de Glaucoma , Austrália/epidemiologia , Acuidade Visual , Resultado do Tratamento , Glaucoma/cirurgia , Glaucoma/fisiopatologia , Glaucoma/etnologia , Glaucoma/complicações , Facoemulsificação/métodos , Seguimentos , Idoso de 80 Anos ou mais , Povo Asiático/etnologia , Catarata/complicações , Estudos Retrospectivos
17.
Klin Monbl Augenheilkd ; 241(4): 347-354, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38653289

RESUMO

BACKGROUND: Various yoga positions may have an unfavorable impact on intraocular pressure (IOP) and may therefore be seen as a potential risk factor for the progression of glaucoma. The new "iCare HOME2" is a handheld self-tonometer for IOP measurements outside clinical settings. This is the first study to evaluate the immediate effect of common yoga postures on the IOP of healthy and glaucomatous eyes using the "iCare HOME2" self-tonometer and to compare the time of IOP recovery in both groups. METHODS: This is a single-center, prospective, observational study including 25 healthy and 25 glaucoma patients performing the following yoga positions: "legs up" (Viparita Karani), "bend over" (Uttanasana), "plough pose" (Halasana), and the "down face dog" (Adho Mukha Svanasana) for 90 s each, with a 2-min break in between. IOP was measured with the "iCare HOME2" before, during, and after each position. RESULTS: IOP significantly increased in all eyes in all positions (p < 0.05), showing no statistically significant difference between healthy or glaucomatous eyes (p > 0.05). The mean rise in IOP in healthy subjects was 1.6 mmHg (SD 1.42; p = 0.037), 14.4 mmHg (SD 4.48; p < 0.001), 7.5 mmHg (SD 4.21; p < 0.001), and 16.5 mmHg (SD 3.71; p < 0.001), whereas in glaucoma patients, IOP rose by 2.8 mmHg (SD 2.8; p = 0.017), 11.6 mmHg (SD 3.86; p < 0.001), 6.0 mmHg (SD 2.24; p < 0.001), and 15.1 mmHg (SD 4.44; p < 0.001) during the above listed yoga positions, repsectively. The highest increase in IOP was seen in the down face position, reaching mean IOP values above 31 mmHg in both study groups. IOP elevation was observed immediately after assuming the yoga position, with no significant change during the following 90 s of holding each pose (p > 0.05). All IOP values returned to baseline level in all individuals, with no significant difference between healthy and glaucoma participants. CONCLUSION: Our data show that common yoga positions can lead to an acute IOP elevation of up to 31 mmHg in healthy as well as glaucoma eyes, with higher IOP values during head-down positions. Given that IOP peaks are a major risk factor for glaucomatous optic neuropathy, we generally advise glaucoma patients to carefully choose their yoga exercises. If and to what extent practicing yoga leads to glaucoma progression, however, remains unclear and warrants further research.


Assuntos
Glaucoma , Pressão Intraocular , Tonometria Ocular , Yoga , Humanos , Pressão Intraocular/fisiologia , Masculino , Feminino , Tonometria Ocular/métodos , Tonometria Ocular/instrumentação , Pessoa de Meia-Idade , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Glaucoma/terapia , Reprodutibilidade dos Testes , Adulto , Desenho de Equipamento , Sensibilidade e Especificidade , Análise de Falha de Equipamento , Idoso , Estudos Prospectivos
18.
Int Ophthalmol ; 44(1): 188, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38647698

RESUMO

PURPOSE: This study aimed to assess the association between migraine headache and glaucoma among the adult population living in Armenia. METHODS: This case-control study recruited 145 cases with glaucoma and 250 controls without glaucoma and other ocular disorders except refractive error from Optomed Canada Diagnostic Eye Center in Armenia. A structured questionnaire contained questions on socio-demographics, family history of glaucoma and stroke, ocular health, smoking, migraine, and obstructive sleep apnea. The Migraine Screening Questionnaire assessed possible migraine and the Berlin Questionnaire measured obstructive sleep apnea. RESULTS: The mean ages of cases and controls were 63.3 (SD = 12.3) and 39.5 (SD = 13.5), respectively. Females comprised 62.8% of cases and 69.1% of controls. A total of 17.8% of cases and 19.0% of controls had possible migraine. In the adjusted analysis older age (OR 1.17; 95% CI 1.12; 1.23), average/lower than average socio-economic status (OR 5.27; 95% CI 1.30; 21.3), and family history of glaucoma (OR 4.25; 95% CI 1.51; 11.9) were associated with high-tension glaucoma. CONCLUSION: Timely case detection of glaucoma among those with average/low socio-economic status and those with family history of glaucoma could prevent further progression of the disease. Further studies to explore the relationship between migraine headache and specific types of glaucoma may be worthwhile.


Assuntos
Glaucoma , Transtornos de Enxaqueca , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Transtornos de Enxaqueca/epidemiologia , Transtornos de Enxaqueca/diagnóstico , Transtornos de Enxaqueca/complicações , Armênia/epidemiologia , Fatores de Risco , Estudos de Casos e Controles , Adulto , Glaucoma/epidemiologia , Glaucoma/diagnóstico , Glaucoma/complicações , Glaucoma/fisiopatologia , Idoso , Inquéritos e Questionários , Pressão Intraocular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA