Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
J Clin Ultrasound ; 52(3): 318-320, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38100183

RESUMO

This article reports a case of LV outflow obstruction caused by abnormalities of the anterior leaflet connection of the mitral papillary muscle, aiming to highlight the importance of combined multimodal imaging in the differential diagnosis of the etiology of LV outflow obstruction.


Assuntos
Cardiomiopatia Hipertrófica , Obstrução da Via de Saída Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo , Humanos , Músculos Papilares/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Valva Mitral/diagnóstico por imagem , Imagem Multimodal/efeitos adversos , Cardiomiopatia Hipertrófica/complicações
2.
Medicina (Kaunas) ; 59(7)2023 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-37512035

RESUMO

COVID-19 infection often produces cardiovascular complications, which can range from mild to severe and influence the overall prognosis. Imaging is the cornerstone for diagnosing initial COVID-19 cardiovascular involvement as well as treatment guidance. In this review, we present the current state of the literature on this subject while also emphasizing possible algorithms for indicating and executing these investigations.


Assuntos
COVID-19 , Cardiopatias , Humanos , COVID-19/complicações , Coração/diagnóstico por imagem , Cardiopatias/diagnóstico por imagem , Cardiopatias/etiologia , Imagem Multimodal/efeitos adversos , Imagem Multimodal/métodos , Pulmão , Imageamento por Ressonância Magnética/efeitos adversos
3.
Medicina (Kaunas) ; 59(5)2023 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-37241128

RESUMO

Diabetic retinopathy is a form of diabetic microangiopathy, and vascular hyperpermeability in the macula leads to retinal thickening and concomitant reduction of visual acuity in diabetic macular edema (DME). In this review, we discuss multimodal fundus imaging, comparing the pathogenesis and interventions. Clinicians diagnose DME using two major criteria, clinically significant macular edema by fundus examination and center-involving diabetic macular edema using optical coherence tomography (OCT), to determine the appropriate treatment. In addition to fundus photography, fluorescein angiography (FA) is a classical modality to evaluate morphological and functional changes in retinal capillaries, e.g., microaneurysms, capillary nonperfusion, and fluorescein leakage. Recently, optical coherence tomography angiography (OCTA) has allowed us to evaluate the three-dimensional structure of the retinal vasculature and newly demonstrated that lamellar capillary nonperfusion in the deep layer is associated with retinal edema. The clinical application of OCT has accelerated our understanding of various neuronal damages in DME. Retinal thickness measured by OCT enables us to quantitatively assess therapeutic effects. Sectional OCT images depict the deformation of neural tissues, e.g., cystoid macular edema, serous retinal detachment, and sponge-like retinal swelling. The disorganization of retinal inner layers (DRIL) and foveal photoreceptor damage, biomarkers of neurodegeneration, are associated with visual impairment. Fundus autofluorescence derives from the retinal pigment epithelium (RPE) and its qualitative and quantitative changes suggest that the RPE damage contributes to the neuronal changes in DME. These clinical findings on multimodal imaging help to elucidate the pathology in the neurovascular units and lead to the next generation of clinical and translational research in DME.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Edema Macular , Humanos , Edema Macular/diagnóstico por imagem , Edema Macular/etiologia , Retinopatia Diabética/diagnóstico por imagem , Estudos Retrospectivos , Retina/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Imagem Multimodal/efeitos adversos , Diabetes Mellitus/patologia
4.
Artigo em Inglês | MEDLINE | ID: mdl-36734898

RESUMO

Dilated cardiomyopathy (DCM) is distinguished by ventricular chamber expansion, systolic dysfunction, and normal left ventricular (LV) wall thickness, and is mainly caused due to genetic or environmental factors; however, its aetiology is undetermined in the majority of patients. The focus of this work is on pathogenesis, small animal models, as well as the herbal medicinal approach, and the most recent advances in imaging modalities for patients with dilated cardiomyopathy. Several small animal models have been proposed over the last few years to mimic various pathomechanisms that contribute to dilated cardiomyopathy. Surgical procedures, gene mutations, and drug therapies are all characteristic features of these models. The pros and cons, including heart failure stimulation of extensively established small animal models for dilated cardiomyopathy, are illustrated, as these models tend to procure key insights and contribute to the development of innovative treatment techniques for patients. Traditional medicinal plants used as treatment in these models are also discussed, along with contemporary developments in herbal therapies. In the last few decades, accurate diagnosis, proper recognition of the underlying disease, specific risk stratification, and forecasting of clinical outcome, have indeed improved the health of DCM patients. Cardiac magnetic resonance (CMR) is the bullion criterion for assessing ventricular volume and ejection fraction in a reliable and consistent direction. Other technologies, like strain analysis and 3D echocardiography, have enhanced this technique's predictive and therapeutic potential. Nuclear imaging potentially helps doctors pinpoint the causative factors of left ventricular dysfunction, as with cardiac sarcoidosis and amyloidosis.


Assuntos
Cardiomiopatia Dilatada , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/tratamento farmacológico , Cardiomiopatia Dilatada/etiologia , Volume Sistólico , Coração , Insuficiência Cardíaca/complicações , Imagem Multimodal/efeitos adversos
5.
Monaldi Arch Chest Dis ; 93(4)2022 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-36426901

RESUMO

After heart failure, infectious endocarditis is the second leading cause of death in patients with prosthetic valves. Aortic pseudoaneurysms are a serious complication of infective endocarditis in mechanical or bioprosthetic aortic prostheses. Diagnostic and management challenges are posed by aortic pseudoaneurysms. In these cases, a multi-modality imaging approach with a heart team is recommended. We described two cases of aortic pseudoaneurysms that developed as a result of infective endocarditis. The first case involved a TAVI patient who developed infective endocarditis as a result of diabetic foot complications. Because traditional echocardiography and computed tomography failed to show the anatomy of the lesion, we used 3D printing to show the anatomy, extension of the pseudoaneurysm, and proximity to the right coronary artery. The second case involved a patient who underwent Bentall's surgery with an aortic root and mechanical aortic valve and later developed infective endocarditis complicated by pseudoaneurysms. In this case, 3D printing was used for preoperative surgical planning.


Assuntos
Falso Aneurisma , Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Endocardite/diagnóstico , Endocardite/diagnóstico por imagem , Endocardite Bacteriana/complicações , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/cirurgia , Impressão Tridimensional , Imagem Multimodal/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos
6.
Eur Spine J ; 31(11): 2884-2896, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35931790

RESUMO

PURPOSE: To probe the pathophysiological basis of Modic change (MC) by multimodal imaging rather than by MRI alone. METHODS: Nineteen radiological signs found in mild infections and traumatic endplate fractures were identified by MRI and CT, and by elimination, three signs unique to infection and trauma were distilled. By ranking the Z score, radiological 'Endplate Infection Probability Score' (EIPS) was developed. The score's ability to differentiate infection and traumatic endplate changes (EPC) was validated in a fresh set of 15 patients each, with documented infection and trauma. The EIPS, ESR, CRP, and Numeric Pain Rating Scale (NRS) were then compared between 115 patients with and 80 patients without MC. RESULTS: The EIPS had a confidence of 66.4%, 83% and, 100% for scores of 4, 5 and, 6, respectively, for end plate changes suggesting infection. The mean EIPS was 4.85 ± 1.94 in patients with Modic changes compared to - 0.66 ± 0.49 in patients without Modic changes (p < 0.001). Seventy-eight (67.64%) patients with MC had a score of 6, indicating high infection possibility. There was a difference in the NRS (p < 0.01), ESR (p = 0.05), CRP (p < 0.01), and type of pain (p < 0.01) between patients with and without MC. CONCLUSION: Multimodal imaging showed many radiological signs not easily seen in MRI alone and thus missed in Modic classification. There were distinct radiological differences between EPCs of trauma and infection which allowed the development of an EIPS. The scores showed that 67.64% of our study patients with Modic changes had EPCs resembling infection rather than trauma suggesting the possibility of an infective aetiology and allowing us to propose an alternate theory of 'Primary Endplatitis'.


Assuntos
Degeneração do Disco Intervertebral , Dor Lombar , Humanos , Dor Lombar/diagnóstico por imagem , Dor Lombar/etiologia , Vértebras Lombares , Radiografia , Imageamento por Ressonância Magnética/efeitos adversos , Probabilidade , Imagem Multimodal/efeitos adversos , Degeneração do Disco Intervertebral/diagnóstico por imagem
7.
J Physiol ; 600(18): 4119-4135, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35984854

RESUMO

Hypertensive heart disease (HHD) increases risk of ventricular tachycardia (VT) and ventricular fibrillation (VF). The roles of structural vs. electrophysiological remodelling and age vs. disease progression are not fully understood. This cross-sectional study of cardiac alterations through HHD investigates mechanistic contributions to VT/VF risk. Risk was electrically assessed in Langendorff-perfused, spontaneously hypertensive rat hearts at 6, 12 and 18 months, and paced optical membrane voltage maps were acquired from the left ventricular (LV) free wall epicardium. Distributions of LV patchy fibrosis and 3D cellular architecture in representative anterior LV mid-wall regions were quantified from macroscopic and microscopic fluorescence images of optically cleared tissue. Imaging showed increased fibrosis from 6 months, particularly in the inner LV free wall. Myocyte cross-section increased at 12 months, while inter-myocyte connections reduced markedly with fibrosis. Conduction velocity decreased from 12 months, especially transverse to the myofibre direction, with rate-dependent anisotropy at 12 and 18 months, but not earlier. Action potential duration (APD) increased when clustered by age, as did APD dispersion at 12 and 18 months. Among 10 structural, functional and age variables, the most reliably linked were VT/VF risk, general LV fibrosis, a measure quantifying patchy fibrosis, and non-age clustered APD dispersion. VT/VF risk related to a quantified measure of patchy fibrosis, but age did not factor strongly. The findings are consistent with the notion that VT/VF risk is associated with rate-dependent repolarization heterogeneity caused by structural remodelling and reduced lateral electrical coupling between LV myocytes, providing a substrate for heterogeneous intramural activation as HHD progresses. KEY POINTS: There is heightened arrhythmic risk with progression of hypertensive heart disease. Risk is related to increasing left ventricular fibrosis, but the nature of this relationship has not been quantified. This study is a novel systematic characterization of changes in active electrical properties and fibrotic remodelling during progression of hypertensive heart disease in a well-established animal disease model. Arrhythmic risk is predicted by several left ventricular measures, in particular fibrosis quantity and structure, and epicardial action potential duration dispersion. Age alone is not a good predictor of risk. An improved understanding of links between arrhythmic risk and fibrotic architectures in progressive hypertensive heart disease aids better interpretation of late gadolinium-enhanced cardiac magnetic resonance imaging and electrical mapping signals.


Assuntos
Taquicardia Ventricular , Potenciais de Ação/fisiologia , Animais , Arritmias Cardíacas/complicações , Arritmias Cardíacas/etiologia , Estudos Transversais , Fibrose , Imagem Multimodal/efeitos adversos , Pericárdio , Ratos , Ratos Endogâmicos SHR , Taquicardia Ventricular/etiologia , Fibrilação Ventricular
8.
Pediatr Cardiol ; 42(4): 926-933, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33590323

RESUMO

The aim of the study is to evaluate the impact of multimodality imaging technology during percutaneous pulmonary valve implantation (PPVI). Among percutaneous procedures, PPVI traditionally has one of the highest patient radiation exposures. Different protocol modifications have been implemented to address this problem (i.e., improvements in guidance systems, delivery systems, valve design, post-implantation evaluation). Although the effectiveness of individual modifications has been proven, the effect of an approach which combines these changes has not been reported. We performed a retrospective chart review of 76 patients who underwent PPVI between January 2018 and December 2019. Patients were classified in "Traditional protocol," using routine biplane angiography and/or 3D rotational angiography (3DRA); and "Multimodality protocol" that included the use of VesselNavigator for guidance, selective 3DRA for coronary evaluation, Long DrySeal Sheath for valve delivery, and Intracardiac Echocardiography for valve evaluation after implantation. Radiation metrics, procedural time, and clinical outcomes were compared between groups. When the traditional protocol group was compared with the multimodality protocol group, a significant reduction was described for total fluoroscopy time (31.6 min vs. 26.2 min), dose of contrast per kilogram (1.8 mL/Kg vs. 0.9 mL/Kg), DAP/kg (26.6 µGy·m2/kg vs. 19.9 µGy·m2/kg), and Air Kerma (194 mGy vs. 99.9 mGy). A reduction for procedure time was noted (140 min vs. 116.5 min), but this was not statistically significant. There was no difference in clinical outcomes or the presence of complications between groups. The combination of novel technology in PPVI caused a significant reduction in radiation metrics without increasing the complication rate in our population.


Assuntos
Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Valva Pulmonar/cirurgia , Exposição à Radiação/prevenção & controle , Adolescente , Angiografia/métodos , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia/métodos , Feminino , Fluoroscopia/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Imagem Multimodal/efeitos adversos , Imagem Multimodal/métodos , Insuficiência da Valva Pulmonar/cirurgia , Exposição à Radiação/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
9.
Urolithiasis ; 49(2): 173-180, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33416916

RESUMO

In this study, we aimed to compare clinical and technical outcomes between pediatric patients who underwent percutaneous nephrolithotomy (PCNL) under fluoroscopy (FL) and those that underwent this procedure under FL with ultrasound assistance (FLUSA). The data of 66 PCNL patients were analyzed retrospectively. Renal puncture was successful in 22 patients in the FLUSA group and 44 patients in the FL group. In all cases, FL was used for tract dilation and confirmation of ureteral catheter positioning at the beginning of the procedure. The sample consisted of 46 males and 20 females with a mean age of 7.2 ± 2.1 years (range 1-17 years). Stone size varied from 8.0 to 75.4 mm, and 89% of patients achieved a completely stone-free state. The median puncture time was 130.5 ± 25.3 s for FLUSA and 295 ± 82.8 s for FL, the median fluoroscopic screening time was 95 ± 33 and 230 ± 116 s, respectively, and the median radiation dose was 19.04 ± 9.9 dGy/cm2 and 54 ± 21.4 dGy/cm2, respectively. The median puncture time, fluoroscopic screening time, and radiation dose were statistically lower in the FLUSA group (p = 0.001, Mann-Whitney U test). The greatest problem in PCNL is the use of fluoroscopy. Due to some anatomical differences from adults, applying PCNL in pediatric patients using only ultrasound may decrease the success rate. Puncture with ultrasound significantly reduces the radiation dose in children. Puncture with ultrasound and dilation under fluoroscopy is a successful and safe treatment method with low morbidity and high success rates and shorter hospital stay in pediatric patients.


Assuntos
Dilatação/métodos , Fluoroscopia/efeitos adversos , Cálculos Renais/cirurgia , Nefrolitotomia Percutânea/métodos , Ultrassonografia de Intervenção , Adolescente , Fatores Etários , Catéteres , Criança , Pré-Escolar , Dilatação/instrumentação , Feminino , Fluoroscopia/instrumentação , Fluoroscopia/métodos , Humanos , Lactente , Masculino , Imagem Multimodal/efeitos adversos , Imagem Multimodal/instrumentação , Imagem Multimodal/métodos , Nefrolitotomia Percutânea/efeitos adversos , Nefrolitotomia Percutânea/instrumentação , Doses de Radiação , Exposição à Radiação/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Ureter/anatomia & histologia , Ureter/diagnóstico por imagem
10.
Stroke ; 52(1): 313-316, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33250038

RESUMO

BACKGROUND AND PURPOSE: Contrast-enhanced noninvasive angiography and perfusion imaging are recommended to identify eligible patients for endovascular therapy (EVT) in extended time windows (>6 hours or wake-up). If eligible, additional intraarterial contrast exposure will occur during EVT. We aimed to study the renal safety in the DEFUSE 3 (Endovascular Therapy Following Imaging Evaluation for Ischemic Stroke) population, selected with contrast-enhanced multimodal Imaging and randomized to EVT versus medical management. METHODS: In the randomized DEFUSE 3 trial population, we compared changes in serum creatinine between baseline (before randomization) and 24 hours later. The primary outcome was the relative change in creatinine level between baseline and 24 hours in the EVT versus medical arm. The secondary outcome was a comparison between computed tomography (CT) versus magnetic resonance imaging selection in the EVT arm. The safety outcome was a comparison of the proportion of patients with criteria for contrast-associated kidney injury in the EVT versus medical arm and a comparison between CT versus magnetic resonance imaging selection in the EVT arm. RESULTS: In the DEFUSE 3 population (n=182, age 69±13, 51% female), mean creatinine decreased from a baseline of 0.98±0.33 mg/dL to 0.88±0.28 mg/dL at 24 hours (P<0.001). There was no difference in change between treatment groups: relative to baseline, there was a 6.3% reduction in the EVT group versus 9.2% in the medical group, P=0.294. Absolute decrease -0.08±0.18 in EVT versus -0.12±0.18 in medical, P=0.135; Among patients treated with EVT, there was no difference in 24-hour creatinine level changes between patients who were selected with CT angiography/CT perfusion (-0.08±0.18) versus magnetic resonance imaging (-0.07±0.19), P=0.808 or 6.8% reduction versus 4.8%, P=0.696. In the EVT arm, contrast-associated kidney injury was encountered in 4 out of 91 (4.4%) versus 2/90 (2.2%) in the medical arm P=0.682. In the EVT arm, contrast-associated kidney injury was evenly distributed between magnetic resonance imaging (1/22, 4.6%) versus CT 3 out of 69 (4.4%), P=1.0. CONCLUSIONS: Perfusion imaging before EVT was not associated with evidence of decline in renal function. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02586415.


Assuntos
Meios de Contraste/efeitos adversos , Procedimentos Endovasculares/métodos , Nefropatias/induzido quimicamente , Imagem Multimodal/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Creatinina/sangue , Feminino , Humanos , Nefropatias/epidemiologia , Testes de Função Renal , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão , Estudos Prospectivos , Trombectomia , Tomografia Computadorizada por Raios X/efeitos adversos
11.
Int J Mol Sci ; 21(8)2020 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-32340284

RESUMO

Atherosclerosis is a lipoprotein-driven inflammatory disorder leading to a plaque formation at specific sites of the arterial tree. After decades of slow progression, atherosclerotic plaque rupture and formation of thrombi are the major factors responsible for the development of acute coronary syndromes (ACSs). In this regard, the detection of high-risk (vulnerable) plaques is an ultimate goal in the management of atherosclerosis and cardiovascular diseases (CVDs). Vulnerable plaques have specific morphological features that make their detection possible, hence allowing for identification of high-risk patients and the tailoring of therapy. Plaque ruptures predominantly occur amongst lesions characterized as thin-cap fibroatheromas (TCFA). Plaques without a rupture, such as plaque erosions, are also thrombi-forming lesions on the most frequent pathological intimal thickening or fibroatheromas. Many attempts to comprehensively identify vulnerable plaque constituents with different invasive and non-invasive imaging technologies have been made. In this review, advantages and limitations of invasive and non-invasive imaging modalities currently available for the identification of plaque components and morphologic features associated with plaque vulnerability, as well as their clinical diagnostic and prognostic value, were discussed.


Assuntos
Aterosclerose/diagnóstico , Diagnóstico por Imagem , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Animais , Aterosclerose/etiologia , Aterosclerose/metabolismo , Biomarcadores , Diagnóstico por Imagem/efeitos adversos , Diagnóstico por Imagem/métodos , Suscetibilidade a Doenças , Humanos , Imagem Molecular , Imagem Multimodal/efeitos adversos , Imagem Multimodal/métodos , Placa Aterosclerótica/metabolismo , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Proc Natl Acad Sci U S A ; 116(37): 18590-18596, 2019 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-31451630

RESUMO

Biocompatible gold nanoparticles designed to absorb light at wavelengths of high tissue transparency have been of particular interest for biomedical applications. The ability of such nanoparticles to convert absorbed near-infrared light to heat and induce highly localized hyperthermia has been shown to be highly effective for photothermal cancer therapy, resulting in cell death and tumor remission in a multitude of preclinical animal models. Here we report the initial results of a clinical trial in which laser-excited gold-silica nanoshells (GSNs) were used in combination with magnetic resonance-ultrasound fusion imaging to focally ablate low-intermediate-grade tumors within the prostate. The overall goal is to provide highly localized regional control of prostate cancer that also results in greatly reduced patient morbidity and improved functional outcomes. This pilot device study reports feasibility and safety data from 16 cases of patients diagnosed with low- or intermediate-risk localized prostate cancer. After GSN infusion and high-precision laser ablation, patients underwent multiparametric MRI of the prostate at 48 to 72 h, followed by postprocedure mpMRI/ultrasound targeted fusion biopsies at 3 and 12 mo, as well as a standard 12-core systematic biopsy at 12 mo. GSN-mediated focal laser ablation was successfully achieved in 94% (15/16) of patients, with no significant difference in International Prostate Symptom Score or Sexual Health Inventory for Men observed after treatment. This treatment protocol appears to be feasible and safe in men with low- or intermediate-risk localized prostate cancer without serious complications or deleterious changes in genitourinary function.


Assuntos
Terapia a Laser/instrumentação , Nanopartículas Metálicas/administração & dosagem , Neoplasias da Próstata/cirurgia , Idoso , Estudos de Viabilidade , Seguimentos , Ouro/administração & dosagem , Ouro/efeitos da radiação , Humanos , Biópsia Guiada por Imagem/métodos , Raios Infravermelhos , Terapia a Laser/efeitos adversos , Terapia a Laser/métodos , Imagem por Ressonância Magnética Intervencionista/efeitos adversos , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Nanopartículas Metálicas/efeitos da radiação , Pessoa de Meia-Idade , Imagem Multimodal/efeitos adversos , Imagem Multimodal/instrumentação , Imagem Multimodal/métodos , Nanoconchas/administração & dosagem , Nanoconchas/efeitos da radiação , Oligopeptídeos , Órgãos em Risco/efeitos da radiação , Ereção Peniana/efeitos da radiação , Projetos Piloto , Próstata/diagnóstico por imagem , Próstata/patologia , Próstata/cirurgia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Saúde Sexual , Ultrassonografia de Intervenção/efeitos adversos , Ultrassonografia de Intervenção/instrumentação , Ultrassonografia de Intervenção/métodos , Sistema Urogenital/efeitos da radiação
13.
J Stroke Cerebrovasc Dis ; 28(7): 2031-2037, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31047820

RESUMO

BACKGROUND: Multimodal computed tomography imaging is used to identify eligible patients for intra-arterial treatment. A concern with this method is the multiple use of iodinated contrast material which presents a possible risk of renal toxicity. We compared the safety of intra-arterial treatment versus intravenous treatment during acute ischemic stroke treatment with a focus on renal safety. METHODS: Adult acute ischemic stroke patients who underwent a baseline Multimodal computed tomography, then intra-arterial treatment and/or intravenous treatment were identified. Primary outcomes were acute kidney injury and changes in serum creatinine at 24-72 hours (Δ serum creatinine). RESULTS: A total of 184 patients received intra-arterial treatment, while 68 received intravenous treatment. There were no differences in mean serum creatinine in the 24-72-hour time period, 24-hour urine volume, or rates of acute kidney injury, dialysis, or mortality. Univariate regression analysis identified diabetes mellitus, operation duration and times of embolectomy as predictors of creatinine increase while the multiple regression model identified diabetes mellitus as the only significant predictor. CONCLUSIONS: There were no significant differences in renal safety between the intra-arterial treatment and intravenous treatment groups. Diabetes mellitus may be a predictor of acute kidney injury. The use of Multimodal computed tomography imaging in the selection of patients who could benefit from endovascular therapy is safe.


Assuntos
Injúria Renal Aguda/induzido quimicamente , Isquemia Encefálica/diagnóstico por imagem , Meios de Contraste/efeitos adversos , Procedimentos Endovasculares/métodos , Iohexol/efeitos adversos , Tomografia Computadorizada Multidetectores/efeitos adversos , Imagem de Perfusão/efeitos adversos , Acidente Vascular Cerebral/diagnóstico por imagem , Injúria Renal Aguda/sangue , Injúria Renal Aguda/diagnóstico , Idoso , Biomarcadores/sangue , Isquemia Encefálica/terapia , Tomada de Decisão Clínica , Meios de Contraste/administração & dosagem , Creatinina/sangue , Procedimentos Endovasculares/efeitos adversos , Feminino , Fibrinolíticos/administração & dosagem , Humanos , Infusões Intra-Arteriais , Infusões Intravenosas , Iohexol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/efeitos adversos , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/terapia , Trombectomia/métodos , Terapia Trombolítica/métodos , Resultado do Tratamento
14.
Radiol Med ; 124(8): 768-776, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30771217

RESUMO

Hybrid imaging procedures such as single-photon emission computed tomography/computed tomography (SPECT/CT) and positron emission tomography/computed tomography (PET/CT) showed a rapid diffusion in recent years because of their high sensitivity, specificity, and accuracy, due to a more accurate localization and definition of scintigraphic findings. However, hybrid systems inevitably lead to an increase in patient radiation exposure because of the added CT component. Effective doses due to the radiopharmaceuticals can be estimated by multiplying the administered activities by the effective dose coefficients, while for the CT component the dose-length product can be multiplied by a conversion coefficient k. However, the effective dose value is subject to a high degree of uncertainty and must be interpreted as a broad, generic estimate of biologic risk. Although the effective dose can be used to estimate and compare the risk of radiation exposure across multiple imaging techniques, clinicians should be aware that it represents a generic evaluation of the risk derived from a given procedure to a generic model of the human body. It cannot be applied to a single individual and should not be used for epidemiologic studies or the estimation of population risks due to the inherent uncertainties and oversimplifications involved. Practical ways to reduce radiation dose to patients eligible for hybrid imaging involve adjustments to both the planning phase and throughout the execution of the study. These methods include individual justification of radiation exposure, radiopharmaceutical choice, adherence to diagnostic reference levels (DLR), patient hydration and bladder voiding, adoption of new technical devices (sensitive detectors or collimators) with new reconstruction algorithms, and implementation of appropriate CT protocols and exposure parameters.


Assuntos
Imagem Multimodal/efeitos adversos , Medicina Nuclear , Doses de Radiação , Exposição à Radiação/prevenção & controle , Compostos Radiofarmacêuticos/efeitos adversos , Humanos , Imagem Multimodal/métodos , Imagem Multimodal/estatística & dados numéricos , Imagem Multimodal/tendências , Medicina Nuclear/estatística & dados numéricos , Medicina Nuclear/tendências , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/efeitos adversos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/estatística & dados numéricos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/tendências , Editoração/estatística & dados numéricos , Editoração/tendências , Compostos Radiofarmacêuticos/administração & dosagem , Risco , Sensibilidade e Especificidade , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/tendências , Tomografia Computadorizada por Raios X/efeitos adversos
15.
Methodist Debakey Cardiovasc J ; 14(3): 200-207, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30410650

RESUMO

Advanced imaging for intraoperative evaluation of venous pathologies has played an increasingly significant role in this era of evolving minimally invasive surgical and interventional therapies. The evolution of dedicated venous stents and other novel interventional devices has mandated the need for advanced imaging tools to optimize safe and accurate device deployment. Most venous interventions are typically performed using a combination of standard 2-dimensional (2D) fluoroscopy, digital-subtraction angiography, and intravascular ultrasound imaging techniques. Latest generation computer tomography (CT) and magnetic resonance imaging (MRI) scanners have been shown to provide high-resolution 3D and 4D information about venous vasculature. In addition to morphological imaging, novel MRI techniques such as 3D time-resolved MR venography and 4D flow sequences can provide quantitative information and help visualize intricate flow patterns to better understand complex venous pathologies. Moreover, the high-fidelity information from multiple imaging techniques can be integrated using image fusion to overcome the limitations of current intraoperative imaging techniques. For example, the limitations of standard 2D fluoroscopy and luminal angiography can be compensated for by perivascular and soft-tissue information from MRI during complex venous interventions using image fusion techniques. Intraoperative dynamic evaluation of devices such as venous stents and real-time understanding of changes in flow patterns during venous interventions may be routinely available in future interventional suites with integrated multimodality CT or MR imaging capabilities. The purpose of this review is to discuss the outlook for intraoperative imaging and multimodality image fusion techniques and highlight their value during complex venous interventions.


Assuntos
Procedimentos Endovasculares/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Imagem Multimodal/métodos , Radiografia Intervencionista/métodos , Ultrassonografia de Intervenção/métodos , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/cirurgia , Veias/diagnóstico por imagem , Veias/cirurgia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Angiografia por Ressonância Magnética , Imagem por Ressonância Magnética Intervencionista/efeitos adversos , Pessoa de Meia-Idade , Imagem Multimodal/efeitos adversos , Flebografia , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/efeitos adversos , Resultado do Tratamento , Ultrassonografia de Intervenção/efeitos adversos
16.
Pediatr Cardiol ; 39(7): 1308-1314, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29744658

RESUMO

A comprehensive understanding of the native pulmonary blood supply is crucial in newborns with pulmonary atresia with ventricular septal defect and aortopulmonary collaterals (PA/VSD/MAPCA). We sought to describe the accuracy in terms of identifying native pulmonary arteries, radiation dose and anaesthetic time associated with multi-modality imaging in these patients, prior to their first therapeutic intervention. Furthermore, we wanted to evaluate the cumulative radiations dose and anaesthetic time over the study period. Patients with PA/VSD/MAPCA diagnosed at < 100 days between 2004 and 2014 were identified. Cumulative radiation dose and anaesthetic times were calculated, with imaging results compared with intraoperative findings. We then calculated the cumulative risks to date for all surviving children. Of 19 eligible patients, 2 had echocardiography only prior to first intervention. The remaining 17 patients underwent 13 MRIs, 4 CT scans and 13 cardiac catheterization procedures. The mean radiation dose was 169 mGy cm2 (47-461 mGy cm2), and mean anaesthetic time was 111 min (33-185 min). 3 children had MRI only with no radiation exposure, and one child had CT only with no anaesthetic. Early cross-sectional imaging allowed for delayed catheterisation, but without significantly reducing radiation burden or anaesthetic time. The maximum cumulative radiation dose was 8022 mGy cm2 in a 6-year-old patient and 1263 min of anaesthetic at 5 years. There is the potential to generate very high radiation doses and anaesthetic times from diagnostic imaging alone in these patients. As survival continues to improve in many congenital heart defects, the important risks of serial diagnostic imaging must be considered when planning long-term management.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Defeitos dos Septos Cardíacos/diagnóstico por imagem , Imageamento por Ressonância Magnética/efeitos adversos , Atresia Pulmonar/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/efeitos adversos , Adolescente , Anestesia/efeitos adversos , Anestesia/estatística & dados numéricos , Anestésicos/administração & dosagem , Anestésicos/efeitos adversos , Cateterismo Cardíaco/estatística & dados numéricos , Criança , Pré-Escolar , Circulação Colateral , Ecocardiografia/estatística & dados numéricos , Feminino , Defeitos dos Septos Cardíacos/cirurgia , Humanos , Lactente , Recém-Nascido , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , Imagem Multimodal/efeitos adversos , Imagem Multimodal/métodos , Artéria Pulmonar/diagnóstico por imagem , Atresia Pulmonar/cirurgia , Estudos Retrospectivos , Medição de Risco/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Reino Unido
17.
Radiology ; 286(2): 568-570, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28858565

RESUMO

In this report, a case of fire in a positron emission tomography (PET)/magnetic resonance (MR) imaging system due to blanket combustion is discussed. Manufacturing companies routinely use copper fibers for blanket fabrication, and these fibers may remain within the blanket hem. By folding a blanket with these copper fibers within an MR imaging system, one can create an electrical current loop with a major risk of local excessive heating, burn injury, and fire. This hazard applies to all MR imaging systems. Hybrid PET/MR imaging systems may be particularly vulnerable to this situation, because blankets are commonly used for fluorodeoxyglucose PET to maintain a normal body temperature and to avoid fluorodeoxyglucose uptake in brown adipose tissue. © RSNA, 2017.


Assuntos
Roupas de Cama, Mesa e Banho/efeitos adversos , Incêndios , Imageamento por Ressonância Magnética/efeitos adversos , Metais/administração & dosagem , Tomografia por Emissão de Pósitrons/efeitos adversos , Feminino , Humanos , Pessoa de Meia-Idade , Imagem Multimodal/efeitos adversos
18.
Theranostics ; 8(22): 6233-6247, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30613294

RESUMO

The blood-brain barrier presents a major challenge for the delivery of therapeutic agents to the brain; however, it can be transiently opened by combining low intensity ultrasound with microbubble infusion. Studies evaluating this technology have largely been performed in rodents, including models of neurological conditions. However, despite promising outcomes in terms of drug delivery and the amelioration of neurological impairments, the potential for long-term adverse effects presents a major concern in the context of clinical applications. Methods: To fill this gap, we repeatedly treated 12-month-old wild-type mice with ultrasound, followed by a multimodal analysis for up to 18 months of age. Results: We found that spatial memory in these aged mice was not adversely affected as assessed in the active place avoidance test. Sholl analysis of Golgi impregnations in the dentate gyrus of the hippocampus did not reveal any changes to the neuronal cytoarchitecture. Long-term potentiation, a cellular correlate of memory, was still achievable, magnetic resonance spectroscopy revealed no major changes in metabolites, and diffusion tensor imaging revealed normal microstructure and tissue integrity in the hippocampus. More specifically, all measures of diffusion appeared to support a neuroprotective effect of ultrasound treatment on the brain. Conclusion: This multimodal analysis indicates that therapeutic ultrasound for blood-brain barrier opening is safe and potentially protective in the long-term, underscoring its validity as a potential treatment modality for diseases of the brain.


Assuntos
Envelhecimento/efeitos da radiação , Encéfalo/efeitos da radiação , Envelhecimento/fisiologia , Animais , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Feminino , Hipocampo/diagnóstico por imagem , Hipocampo/fisiologia , Hipocampo/efeitos da radiação , Camundongos , Camundongos Endogâmicos C57BL , Imagem Multimodal/efeitos adversos , Memória Espacial/efeitos da radiação , Fatores de Tempo , Terapia por Ultrassom/efeitos adversos , Ultrassonografia
19.
JACC Cardiovasc Imaging ; 10(7): 797-818, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28514670

RESUMO

There is a need for consensus recommendations for ionizing radiation dose optimization during multimodality medical imaging in children with congenital and acquired heart disease (CAHD). These children often have complex diseases and may be exposed to a relatively high cumulative burden of ionizing radiation from medical imaging procedures, including cardiac computed tomography, nuclear cardiology studies, and fluoroscopically guided diagnostic and interventional catheterization and electrophysiology procedures. Although these imaging procedures are all essential to the care of children with CAHD and have contributed to meaningfully improved outcomes in these patients, exposure to ionizing radiation is associated with potential risks, including an increased lifetime attributable risk of cancer. The goal of these recommendations is to encourage informed imaging to achieve appropriate study quality at the lowest achievable dose. Other strategies to improve care include a patient-centered approach to imaging, emphasizing education and informed decision making and programmatic approaches to ensure appropriate dose monitoring. Looking ahead, there is a need for standardization of dose metrics across imaging modalities, so as to encourage comparative effectiveness studies across the spectrum of CAHD in children.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Imagem Multimodal/normas , Doses de Radiação , Exposição à Radiação/normas , Radiografia Intervencionista/normas , Cintilografia/normas , Tomografia Computadorizada por Raios X/normas , Adolescente , Fatores Etários , Criança , Pré-Escolar , Consenso , Feminino , Fluoroscopia/normas , Humanos , Lactente , Recém-Nascido , Masculino , Imagem Multimodal/efeitos adversos , Imagem Multimodal/métodos , Segurança do Paciente/normas , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Lesões por Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos , Cintilografia/efeitos adversos , Medição de Risco , Fatores de Risco , Tomografia Computadorizada por Raios X/efeitos adversos
20.
J Ultrasound ; 20(1): 23-31, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28298941

RESUMO

OBJECTIVES: Traditionally, facet joint injections (FJI) are performed under fluoroscopic or computed tomography (CT) guidance, mainly due to the deep anatomical location and the presence of bony landmarks. Fusion imaging technology, which couples the ultrasound scan with the corresponding CT or magnetic resonance (MR) image obtained from the diagnostic examination and reformatted in real time according to the ultrasound scanning plane, allows to combine the panoramic view and the elevated anatomical detail of MR or CT with the ease of use of ultrasound without patient exposure to ionizing radiation. METHODS: Thirty eight patients (24 females; mean age ± SD: 64 ± 9 years) received MR fusion-assisted ultrasound-guided FJI of 1 ml of a mixture of local anaesthetic and corticosteroid using a ultrasound machine (Logiq E9, GE Healthcare) equipped with a GPS-enhanced fusion imaging technology which couples real-time B-mode images with those of the previous recent diagnostic MR examination. Low-dose CT needle positioning confirmation was performed in the first 28 patients. Patients' pain was recorded using a visual analogue scale (VAS), at baseline and at 2, 4 and 8 weeks. RESULTS: All fusion imaging-guided injections were performed successfully. Out of 112, 96 FJI had optimal intra-articular needle positioning (accuracy: 85.7%). Patients VAS significantly decreases after the procedure with no differences among who received CT needle positioning control and who did not receive it. No major complications were observed. CONCLUSIONS: Ultrasound needle guidance with MR fusion assistance allows for safe and effective injection of degenerative facet joint disease.


Assuntos
Injeções Intra-Articulares/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Ultrassonografia/métodos , Articulação Zigapofisária/diagnóstico por imagem , Corticosteroides/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Anestésicos Locais/administração & dosagem , Anti-Inflamatórios/administração & dosagem , Dor Crônica/diagnóstico por imagem , Dor Crônica/tratamento farmacológico , Estudos de Viabilidade , Feminino , Humanos , Injeções Intra-Articulares/efeitos adversos , Injeções Intra-Articulares/instrumentação , Dor Lombar/diagnóstico por imagem , Dor Lombar/tratamento farmacológico , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Mepivacaína/administração & dosagem , Metilprednisolona/administração & dosagem , Metilprednisolona/análogos & derivados , Acetato de Metilprednisolona , Pessoa de Meia-Idade , Imagem Multimodal/efeitos adversos , Imagem Multimodal/instrumentação , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Ultrassonografia/efeitos adversos , Ultrassonografia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA