Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 324
Filtrar
1.
BMC Oral Health ; 23(1): 575, 2023 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-37596610

RESUMO

BACKGROUND: The purpose of this in vitro study was to compare the accuracy of implant placement in model surgeries according to the design of the drills (straight drills or step drills) used to finalize the implant bed during pilot-guided static computer-assisted implant surgery (sCAIS). METHODS: Model surgeries were carried out on resin models randomly assigned to three study groups. Virtual planning software (coDiagnostiX 10.6, Dental Wings, Montreal, Canada) was used to plan the implant positions. In Groups 1 and 2, pilot-guided sCAIS was performed. Straight drills were used in Group 1, and step drills were used in Group 2 to finalize the implant beds. In Group 3, fully guided sCAIS was performed using a universal fully guided kit (RealGUIDE Full Surgical Kit 3DIEMME, RealGUIDE, Cantù, Como, Italy). A total of 90 dental implants (Callus Pro, Callus Implant Solutions GmbH, Nuremberg, Germany) were placed (six implants per model, five models per study group). The primary outcome variables (angular deviation, coronal global deviation, and apical global deviation) were calculated for all implants based on the comparison of the preoperative surgical plan with the postoperative scans. RESULTS: Group 2 (coronal global deviation, 0.78 ± 0.29 mm; apical global deviation, 1.02 ± 0.56 mm) showed significantly lower values of both global deviation variables than Group 1 (coronal global deviation, 0.95 ± 0.20 mm; apical global deviation, 1.42 ± 0.49 mm). However, there was no significant difference in angular deviation between Groups 1 and 2 (7.56 ± 2.92° and 6.44 ± 2.84°). Group 3 produced significantly lower values of all three primary outcome variables (angular deviation, 2.36 ± 0.90°; coronal global deviation, 0.59 ± 0.28 mm; apical global deviation, 0.90 ± 0.29 mm) than Group 1 and significantly lower angular deviation and coronal global deviation values than Group 2. CONCLUSIONS: The design of the drills used to finalize implant osteotomies during pilot-guided sCAIS influences dental implant placement accuracy. Using step drills instead of straight drills for final osteotomies decreases deviation from the surgical plan. The fully guided approach performed better than the pilot-guided sCAIS.


Assuntos
Implantação Dentária , Implantes Dentários , Cirurgia Assistida por Computador , Humanos , Implantação Dentária/instrumentação , Projetos de Pesquisa
2.
BMC Oral Health ; 23(1): 384, 2023 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-37308877

RESUMO

BACKGROUND: The morphologic and dimensional alveolar bone is significant for resorption in the first 3 months after tooth removal because they restrict treatment outcomes with respect to function and esthetic. Following teeth extraction, the width and height of the alveolar ridge contour are reduced in both the horizontal and vertical dimensions. Following implant placement, the gingival morphology should be changed minimally compared to pre-extraction. Surrounding natural-like tissue is also an ultimate goal of the dental implant treatment, which is correlated with the cervical third contour on the anatomical tooth, for comfortable cleansing, food impaction avoidance, and esthetics. PURPOSE: To evaluate the peri-implant soft tissue changes after immediate implant placement (IIP) with the use of a customized titanium healing abutment in the posterior teeth. METHOD: Digital impressions using the intraoral scanner (MEDIT i500) were taken from 30 patients. Customized titanium healing abutments were designed and milled before extraction. Flapless extractions were done using surgical guides, 32 immediate implants placement were done in posterior areas, and healing abutments were placed. Soft tissues were scanned during pre-operation, and post-surgery during the 1st, 3rd, and 6th months. A 3D analysis program (Final Surface) evaluated the gingival margin distance, height, contour width, and volume in each period. SPSS was used to analyze the data with a p-value = 0.05. The between-time interval comparisons were done and the analysis was done using a Multivariate test. RESULTS: Customized titanium healing abutments used in immediate implantation maintained optimal peri-implant mucosa. In intermittent periods, there was no significant reduction in all aspects of the margin distances and heights. During the entire period, the margin height reduction on the buccal, lingual, mesial, and distal was 0.63 mm, 0.93 mm, 0.08 mm, and 0.24 mm, respectively, and contour width reduction on the buccal, lingual, and buccolingual was 0.59 mm, 0.43 mm, and 1.03 mm, respectively. There was a significant reduction in the total buccolingual contour width in the 1st month and total volume in the 3rd to 6th months. CONCLUSIONS: Immediate implant placement with customized titanium healing abutment can achieve the optimal peri-implant mucosa and this protocol is an alternative for soft tissue management.


Assuntos
Implantação Dentária , Implantes Dentários , Humanos , Titânio , Cicatrização , Implantação Dentária/instrumentação , Implantação Dentária/métodos
3.
Periodontol 2000 ; 92(1): 9-12, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35916837

RESUMO

The assortment of periodontal and implant-related treatments has been continuously improved over the last 50 years. Once the decision-making process has been established and the treatment procedure applied, the partial or complete resolution of the problem (eg, periodontal probing depth reduction, clinical attachment level gain, gingival recession reduction, dental hypersensitivity decrease) and a diagnosis change with no or minimal occurrence of adverse events (ie, complications, harms, technical errors, or adverse/side effects) can be expected. The clear identification of the potential types of adverse effects, complications, or even errors is important for contemporary decision-making processes, as they may be related to different local, systemic, and technical aspects. This chapter focused on four core components: (a) providing periodontal definitions for errors, complications, harms, and side effects; (b) defining the types of risk and the clinical impact of adverse effects, errors, and complications in periodontal and peri-implant therapies; (c) evaluating the influence of accidental errors versus the lack of a proper treatment planning; and (d) reporting on the importance of establishing the "net benefit ratio" between the clinical improvements promoted by the therapy and the occurrence of potential adverse events.


Assuntos
Implantação Dentária , Complicações Pós-Operatórias , Humanos , Retração Gengival/etiologia , Implantação Dentária/efeitos adversos , Implantação Dentária/instrumentação , Complicações Pós-Operatórias/etiologia
4.
PLoS One ; 16(10): e0255481, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34673786

RESUMO

The aim of this study was to assess the potential use of a new advanced inertial navigation system for guiding dental implant placement and to compare this approach with standard stereolithographic template guiding. A movement processing unit with a 9-axis absolute orientation sensor was adapted to a surgical handpiece and wired to a computer navigation interface. Sixty implants were placed by 10 operators in 20 jaw models. The 30 implants of the test group were placed in 10 models guided by the new inertial navigation prototype. The 30 implants of the control group were placed in another 10 models using a CAD-CAM template. Both groups were subdivided into experienced and non-experienced operators. Pre- and postoperative computer tomography images were obtained and matched to compare the planned and final implant positions. Four deviation parameters (global, angular, depth, and lateral deviation) were defined and calculated. The primary outcome was the angular deviation between the standard stereolithographic approach and the new inertial navigation system. Results showed no significant differences between both groups, suggesting that surgical navigation based on inertial measurement units (IMUs) could potentially be useful for guiding dental implant placement. However, more studies are still needed to translate this new approach into clinical practice.


Assuntos
Implantação Dentária/métodos , Implantes Dentários , Mandíbula/cirurgia , Modelos Anatômicos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Implantação Dentária/instrumentação , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos
5.
Int J Mol Sci ; 22(3)2021 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-33494539

RESUMO

The objective of this review was to analyze the process of wear of implants leading to the shedding of titanium particles into the peri-implant hard and soft tissues. Titanium is considered highly biocompatible with low corrosion and toxicity, but recent studies indicate that this understanding may be misleading as the properties of the material change drastically when titanium nanoparticles (NPs) are shed from implant surfaces. These NPs are immunogenic and are associated with a macrophage-mediated inflammatory response by the host. The literature discussed in this review indicates that titanium NPs may be shed from implant surfaces at the time of implant placement, under loading conditions, and during implant maintenance procedures. We also discuss the significance of the micro-gap at the implant-abutment interface and the effect of size of the titanium particles on their toxicology. These findings are significant as the titanium particles can have adverse effects on local soft and hard tissues surrounding implants, implant health and prognosis, and even the health of systemic tissues and organs.


Assuntos
Implantes Dentários , Titânio , Desgaste dos Dentes , Força de Mordida , Implantação Dentária/instrumentação , Implantação Dentária/métodos , Humanos , Nanopartículas Metálicas , Fatores de Tempo , Dente Artificial
6.
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1180859

RESUMO

ABSTRACT Objective: To evaluate the improvement in masticatory performances two weeks after posterior implant restoration. Material and Methods: Nine patients with missing first and second molars were included in the study. Masticatory performances were evaluated using subjective and objective methods utilizing color-changeable chewing gum and the visual analog scale (VAS) assessment. The subjects were asked to chew the color-changeable chewing gums before and two weeks after the posterior implant restoration. Their expectations regarding aesthetics and function were verified on the VAS before implant placement. Additionally, the VAS was used for the posttreatment completion rating two weeks after the implant restoration. Results: Significant differences in masticatory performance were noted at baseline (before implant posterior restoration) and two weeks after implant restoration (p<0.05). The posttreatment aesthetic and functional expectations ratings significantly exceeded the expectations (p<0.05). Conclusion: Masticatory performances were improved two weeks after implant restoration. In addition, the significant posttreatment ratings of the patients exceeded their initial expectations. In particular, patients with poor masticatory functions demonstrated significant improvements and satisfaction following implant restoration compared to those with good mastication. These findings indicate that a posterior implant restoration can increase the masticatory performance.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Goma de Mascar/microbiologia , Satisfação do Paciente , Implantação Dentária/instrumentação , Dente Molar/anatomia & histologia , Estatísticas não Paramétricas , Escala Visual Analógica , Indonésia/epidemiologia , Mastigação
7.
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1154999

RESUMO

ABSTRACT Objective: To evaluate the intra-examiner and inter-examiner reliability of linear and curvilinear measurements for the complete assessment of implant sites and jaw pathologies using Cone-Beam Computed Tomography (CBCT). Material and Methods: Fifty cone-beam computed tomographic images of patients were retrieved from the archives of Dentomaxillofacial Radiology. CBCT images taken for implant planning and evaluation of intrabony jaw pathologies (benign cyst/tumor) were included. Two expert oral and maxillofacial radiologists analyzed the images independently and made the measurements. The images for implant planning were analyzed for width, the height of the edentulous site, and the qualitative analysis of bone in the region. Jaw pathologies were assessed for linear dimensions and curvilinear measurements. Results: The inter-observer measurement error for implant site analysis ranged from 0.12 to 0.42 mm with almost perfect agreement (ICC: 0.94 to 1). The inter-observer measurement error for jaw pathology was 0.09 to 0.25 mm (ICC: 0.98-1). Curvilinear measurements showed perfect agreement between the observers. The intraobserver reliability for the various parameters used for the assessment of the implant site and jaw pathologies indicated almost perfect agreement. Conclusion: Reliability between the radiologists is high for various measurements on CBCT images taken for implant planning and jaw pathologies.


Assuntos
Humanos , Patologia Bucal , Diagnóstico por Imagem/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Implantação Dentária/instrumentação , Tomografia Computadorizada de Feixe Cônico , Mandíbula/diagnóstico por imagem , Estudos Retrospectivos , Estudos Observacionais como Assunto/métodos , Precisão da Medição Dimensional , Radiologistas , Índia/epidemiologia , Arcada Osseodentária , Mandíbula/patologia
8.
Plast Reconstr Surg ; 146(6): 768e-776e, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33234971

RESUMO

BACKGROUND: Despite reports demonstrating feasibility of immediate dental implant placement in mandibular reconstruction with free fibula flaps for benign disease, this practice is not routinely used in the oncologic setting. The authors aim to demonstrate the safety of immediate dental implant placement for oncologic mandible reconstruction. METHODS: In 2017, the authors' center began immediate dental implant placement in free fibula flaps for oncologic patients undergoing mandibulectomy reconstruction. Immediate dental implant placement patients were compared to a historical cohort also reconstructed with computer-aided design and manufacturing technology beginning in 2011 (n = 34) as a noninferiority study design. Primary outcomes of interest included 90-day complications, time to radiotherapy, and time to and number of patients achieving dental restoration. RESULTS: Sixty-one patients underwent free fibula flaps following mandibulectomy using computer-aided design and manufacturing. Seventy-two dental implants were placed in the immediate dental implant placement cohort (n = 27). No differences were noted in major or minor 90-day complications between groups (p > 0.05). Radiotherapy was required in 55 percent in the immediate dental implant placement cohort versus 62 percent in the historical cohort, with no significant difference in time to radiotherapy (67.6 days versus 62.2 days, respectively). One dental implant was removed for nonosseointegration noted during vestibuloplasty. Fourteen (51.8 percent) immediate dental implant patients had complete dental restoration at 90 days compared with none in the historical cohort (p < 0.05). CONCLUSIONS: Immediate dental implant placement is a safe procedure with an unchanged short-term complication profile and no delay in radiotherapy initiation. Patients undergoing immediate dental implant placement are more likely to complete full dental rehabilitation. Long-term and health-related quality-of-life outcomes remain to be determined. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, III.


Assuntos
Transplante Ósseo/métodos , Implantação Dentária/métodos , Neoplasias Mandibulares/terapia , Osteotomia Mandibular/efeitos adversos , Reconstrução Mandibular/métodos , Complicações Pós-Operatórias/epidemiologia , Adulto , Idoso , Transplante Ósseo/efeitos adversos , Desenho Assistido por Computador , Implantação Dentária/efeitos adversos , Implantação Dentária/instrumentação , Implantes Dentários/efeitos adversos , Feminino , Fíbula/transplante , Retalhos de Tecido Biológico/efeitos adversos , Retalhos de Tecido Biológico/transplante , Humanos , Masculino , Mandíbula/patologia , Mandíbula/cirurgia , Reconstrução Mandibular/efeitos adversos , Reconstrução Mandibular/instrumentação , Pessoa de Meia-Idade , Osseointegração , Complicações Pós-Operatórias/etiologia , Radioterapia Adjuvante/métodos , Estudos Retrospectivos , Fatores de Tempo , Tempo para o Tratamento , Resultado do Tratamento
9.
Sci Rep ; 10(1): 12446, 2020 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-32709971

RESUMO

The objective of this in vivo study was to compare bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) values of a new implant, designed to be inserted without bone preparation, using two different preparation protocols: no site preparation and prior limited cortical perforation, versus the values of a control implant using a conventional drilling protocol. Forty-one implants were inserted in 13 rabbits. Thirteen test implants with a new thread design were inserted using no bone preparation (NP), 14 test implants were inserted with limited cortical perforation (CP), and 14 conventional implants served as control. Five animals were sacrificed after 21 days and eight animals after 42 days. Histomorphometric analysis was performed and percentage of BIC and BAFO values were measured. ANOVA with Tukey post hoc and Mann-Whitney nonparametric tests were calculated to compare between the groups. Statistical analysis showed no significant difference in the measured values between any of the groups, neither compered by implant nor by compered day. The results demonstrated that biological osseointegration parameters of implant that was inserted without any bone preparation was non-inferior compared to conventional preparation. The clinical relevance is that novel implant designs may not require bone preparation prior to placement.


Assuntos
Interface Osso-Implante/fisiologia , Implantação Dentária/métodos , Implantes Dentários , Planejamento de Prótese Dentária , Osseointegração/fisiologia , Animais , Implantação Dentária/instrumentação , Modelos Animais , Osteotomia , Coelhos , Propriedades de Superfície , Tíbia/fisiologia , Tíbia/cirurgia , Cicatrização/fisiologia
10.
BMC Oral Health ; 20(1): 99, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32264867

RESUMO

BACKGROUND: The aim of this case report was to use a surgical technique for autotransplantation of tooth using virtually planned 3D printed surgical templates for guided osteotomy preparation of the recipient of donor tooth. CASE PRESENTATION: An 18-year-old male patient received autotransplantation of the right mandibular third molar to replace an included right second molar. This procedure was based on guided implant surgery methods by superimposition of DICOM files and 3D data sets of the jaws. In order to design a 3D-printed template with the aid of a fully digital workflow; the third molar was conserved in PRGF during the surgical procedure and the tooth socket was prepared with a template and the help of a 3D-printed donor tooth copy in order to prevent iatrogenic damage to the donor tooth. This template and replica were manufactured using 3D-printing techniques. The transplanted tooth was placed in infra-occlusion and fixed with a suture splint and root canal therapy was performed 15 days later. The intervention was be accomplished by performing preplanned virtual transplantations with guided osteotomies to ensure accurate donor tooth placement in the new recipient site. The 24 months follow-up showed physiological clinical and radiologic results compatible with healing periradicular tissues. CONCLUSIONS: This approach enables the planning and production of a 3D printed surgical template using the latest diagnostic methods and techniques of guided implant surgery. These accurate virtually predesigned surgical templates and printed analogues of the donor tooth could facilitate autotransplantation, ensuring an atraumatic surgical protocol.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Implantação Dentária/métodos , Dente Serotino/diagnóstico por imagem , Dente Serotino/transplante , Impressão Tridimensional , Cirurgia Assistida por Computador/métodos , Transplante Autólogo/métodos , Adolescente , Implantação Dentária/instrumentação , Implantes Dentários , Humanos , Masculino , Duração da Cirurgia , Radiografia Panorâmica , Resultado do Tratamento
11.
Surg Radiol Anat ; 42(7): 823-830, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32246188

RESUMO

PURPOSE: Anatomical knowledge of the zygomatic region is important, because the zygomatic nerve and its branches may suffer lesions during surgical procedures in the periorbital region. The position and frequency of zygomaticofacial foramina (ZFF) may vary between individuals, and between one side and the other in the same individual. In the present study, we analysed the presence and location of ZFF, as well as the distance between them and the orbital cavity, in macerated skulls of adult individuals. METHODS: We examined 287 macerated skulls, of individuals of both sexes, analysing the frequency and location of ZFF and the distance from the ZFF to the margin of the orbital cavity (OC). RESULTS: Zygomaticofacial foramina are very frequent structures which tend to appear singly. They are generally located in the temporal process of the zygomatic bone, but in many cases, they may be located in the mid portion of the bone. They also tend to appear at the same distance from the OC when left and right sides are compared. Sex was an important factor in determining differences in ZFF; the distance from the ZFF to the margin of the OC was greater in males than in females. Sex, age, side and skin colour did not affect the frequency and location of the ZFF. CONCLUSION: We consider that the mid portion of the zygomatic bone is the safest place to anchor zygomatic implants (ZI), since ZFF are less frequently located there than in the temporal process of the zygomatic bone.


Assuntos
Variação Anatômica , Implantação Dentária/efeitos adversos , Nervo Maxilar/anatomia & histologia , Complicações Pós-Operatórias/prevenção & controle , Zigoma/inervação , Adolescente , Adulto , Fatores Etários , Implantação Dentária/instrumentação , Implantação Dentária/métodos , Implantes Dentários/efeitos adversos , Feminino , Hormônios Esteroides Gonadais , Humanos , Masculino , Nervo Maxilar/lesões , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Adulto Jovem , Zigoma/cirurgia
12.
BMC Oral Health ; 20(1): 19, 2020 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-31973705

RESUMO

BACKGROUND: The purpose of this research was to investigate the effects of disinfection and three different sterilization methods on the dimensional changes and mechanical properties of three-dimensional (3D) printed surgical guide for implant therapy. The objective was to assess the effects of sterilization procedures in 3D printed drill guide templates with destructive and non-destructive material testing. METHODS: Fifteen identical drill guide templates were produced using a 3D printer. The surgical guides were classified into five groups: three controls, three disinfected (4% Gigasept®, 60 min), three plasma sterilized, three autoclave sterilized (+ 1 bar, 121 °C, 20 min), and three autoclave sterilized (+ 2 bar, 134 °C, 10 min). The templates were digitalized with a Steinbichler SCAN ST 3D scanner. Length was measured under an SZX16 stereomicroscope. A scanning electron microscope was used to study the surface morphology of the drill templates. The hardness, and flexural and compressive strength were measured to assess any changes in the physical characteristics of the material caused by sterilization. The drill guide templates were also examined with a Dage XiDAT 6600 X-ray. During the X-ray examinations, the following parameters were used: 100 kV voltage, 128 AVG averaging, 0.8 W power. One-way analysis of variance (ANOVA) was used to detect the difference between groups. RESULTS: Evaluation of the hardness measurements of the various specimens shows that the hardness of the material was not changed by the plasma sterilization (p = 0.0680), steam sterilization on 121 °C (p = 0.6033) or disinfection process (p = 0.1399). The statistical analysis revealed significant difference in hardness strength of the autoclave sterilized (134 °C) specimens (p = 0.0002). There was no significant difference between the goups regarding the scanning electron microscopic and stereomicroscopic examinations. There was no significant difference regarding the X-ray visibility of the templates to the effect of the disinfection (p = 0.7844), plasma sterilization (p = 0.4091) and steam sterilization on 121 °C (p = 0.9277) and steam sterilization on 131 °C (p = 0.093). The effect of the sterilization was the same in case of both flexural and compressive strength of the material. CONCLUSIONS: Our findings indicate that plasma sterilization and steam sterilization at 121 °C were both suitable for sterilizing the tested 3D printed surgical guides.


Assuntos
Implantação Dentária/instrumentação , Materiais Dentários/química , Desinfecção , Impressão Tridimensional , Vapor , Esterilização/métodos , Cirurgia Assistida por Computador/instrumentação , Desenho Assistido por Computador , Temperatura Alta , Humanos , Teste de Materiais , Projetos Piloto
14.
J Mater Chem B ; 7(46): 7415-7427, 2019 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-31710069

RESUMO

Although titanium implants have been applied in dental clinics to replace lost teeth and to restore masticatory function for decades, strategies to design the surface of the transmucosal sites of implants to achieve ideal and predictable biological sealing following implantation remain to be optimized. In this study, we hypothesized that gingival epithelial cell (GEC) adhesion and new tissue attachment to titanium sheets/implants could be promoted by the release of plasmid pLAMA3-CM (encoding a motif of the C-terminal globular domain of LAMA3) from a titanium surface. To test this hypothesis, a chitosan/collagen (Chi/Col) coating was immobilized on the surfaces of titanium substrates with nanotube topography (NT-Ti) through cathodic electrophoretic deposition; it was found that pLAMA3-CM could be released from the coating in a highly sustained manner. After culturing on titanium with nanotube topography coated by Chi/Col with the plasmid pLAMA3-CM (Chi/Col/pLAMA3-CM-Ti), human GECs (hGECs) were found to effectively uptake the incorporated plasmids, which resulted in improved attachment, as evidenced by morphological and immunofluorescence analyses. In addition, Chi/Col/pLAMA3-CM-Ti induced better biological sealing at transmucosal sites following immediate implantation into Sprague-Dawley rats. Our findings indicate that the modification of titanium implants by plasmid-mediated pLAMA3-CM gene transfection points to a practical strategy for optimizing biological sealing around the transmucosal sites of implants.


Assuntos
Implantação Dentária/instrumentação , Implantes Dentários , Células Epiteliais/citologia , Gengiva/citologia , Titânio/química , Animais , Materiais Biocompatíveis/química , Adesão Celular , Diferenciação Celular/efeitos dos fármacos , Sobrevivência Celular , Quitosana/química , Materiais Revestidos Biocompatíveis/química , Eletrodos , Eletroforese , Fibroblastos/citologia , Humanos , Masculino , Microscopia de Força Atômica , Nanotubos/química , Plasmídeos , Ratos , Ratos Sprague-Dawley , Enxofre/química , Propriedades de Superfície , Transfecção , Microtomografia por Raio-X
15.
Braz Oral Res ; 33: e046, 2019 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-31188951

RESUMO

The aim of this systematic review was to investigate the association between the different factors of loading protocols and the long-term stability of micro-screws from biomechanical and histological viewpoints. Searches were performed on PubMed, Embase, Cochrane Library, Wanfang and CNKI databases for animal experiments comparing loading protocols and the long-term stability of micro-screws. Among 1011 detected papers, 16 studies met the eligibility criteria and were selected for analysis. Most studies showed medium methodological quality for evaluation of micro-screws' long-term stability. Five studies reported that loading would not destroy the long-term stability of micro-screws. Three studies indicated that low-intensity immediate loading or a 3-week minimal healing time was acceptable. Two studies reported that the loading magnitude was a controversial issue with regard to the micro-screws' long-term stability. Two studies suggested that counterclockwise loading could decrease the long-term stability of micro-screws. In conclusion, immediate loading below 100g force, healing time greater than 3 weeks, regular loading below 200g force and a clockwise direction of force supported the long-term stability of micro-screws. Further studies relating to the combination of varying loading conditions will be needed.


Assuntos
Parafusos Ósseos/normas , Implantação Dentária/métodos , Implantes Dentários/normas , Procedimentos de Ancoragem Ortodôntica/métodos , Animais , Fenômenos Biomecânicos , Implantação Dentária/instrumentação , Desenho de Equipamento , Modelos Animais , Procedimentos de Ancoragem Ortodôntica/instrumentação , Valores de Referência , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento , Cicatrização
16.
Dent Med Probl ; 56(1): 111-116, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30720935

RESUMO

The use of lasers in the field of dentistry has increased recently. Their numerous advantages and applications in soft and hard tissue surgeries make them a great alternative to conservative methods in dental implantology. The most commonly used lasers are diode and erbium-doped yttrium aluminium garnet (Er:YAG) lasers. The Er:YAG laser can be used in implant bed preparation, as it brings no thermal injury to the bone. The laser does not cause bone necrosis and positively affects osseointegration and the healing process. The use of the diode laser in soft tissue surgeries helps to obtain optimal hemostasis. Therefore, it can be used in implant exposure, since it allows performing immediate impressions. The present case report describes the implementation of the Er:YAG laser in the implant bed preparation of a single-tooth dental implant in position 35 (according to the World Dental Federation (Fédération Dentaire Internationale - FDI) notation) for better bone regeneration. The implant exposure was performed with the diode 980-nm laser for hemostasis and immediate impressions. The results of laser employment were compared to traditional drilling and scalpel techniques. The advantages and disadvantages of the application of the above lasers were featured.


Assuntos
Implantação Dentária , Lasers Semicondutores , Lasers de Estado Sólido , Implantação Dentária/instrumentação , Implantação Dentária/métodos , Érbio , Humanos , Cicatrização , Ítrio
17.
Eur J Orthod ; 41(1): 9-20, 2019 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-29608666

RESUMO

Objectives: To assess the failure rates of palatal implants and palatal mini-screws, independently and comparatively, used for supplementing anchorage during orthodontic treatment. Protocol and registration: The protocol was not registered prior to the study. This study was not registered in any publicly assessable database. Materials and methods: Screening for inclusion eligibility, quality assessment of studies, and data extraction was performed independently by two authors. The electronic databases MEDLINE, EMBASE, and CENTRAL, as well as unpublished literature, were searched with no restrictions on publication date or language using detailed strategies. The main outcome assessed was palatal implant or mini-screw failure. Randomized controlled trials were evaluated according to the Cochrane risk of bias tool. Prospective and retrospective studies were graded employing the adjusted predetermined criteria of Bondemark. Results: Twenty-seven studies satisfied the inclusion criteria. Four were RCTs of low risk of bias, 12 were prospective (2 low, 7 unclear, 3 high risk of bias) and 11 were retrospective studies (6 unclear, 5 high risk of bias). Only one retrospective study assessed both palatal implants and mini-screws. Seventeen studies, including the four RCTs, assessed solely palatal implants and nine studies palatal mini-screws. The median failure risk of palatal implants was 6.0 per cent (range: 0.0-26.1%) and of mini-screws 6.1 per cent (range: 0.0-33.3%). The median follow-up period was 17.9 months for palatal implants and 6 months for mini-screws. Limitations: Significant clinical and methodological heterogeneity among studies and highly variable outcomes. Conclusions: Both palatal implants and mini-screws have quite low failure rates that are also comparable, though the median follow-up period of palatal implants was quite larger. Therefore, in regular orthodontic cases, the choice between anchoring devices may rely on other factors, such as costs, patient comfort, personal preferences, familiarity with the device, and insertion procedures.


Assuntos
Parafusos Ósseos , Implantes Dentários , Procedimentos de Ancoragem Ortodôntica/instrumentação , Implantação Dentária/instrumentação , Implantação Dentária/métodos , Humanos , Procedimentos de Ancoragem Ortodôntica/métodos , Estudos Prospectivos , Falha de Prótese , Estudos Retrospectivos
18.
Clin Exp Dent Res ; 5(6): 712-724, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31890309

RESUMO

Objectives: This narrative review is aiming on showing reasons for implant failure, removal techniques, and respective clinical considerations; further, the survival rate of implants in previous failed sites is examined. Materials and methods: Questions have been formulated, answered, and discussed through a literature search including studies assessing implant failure and removal up to 2018. Results: Studies describing reasons for implant failure, implant removal techniques, and the reinsertion of implants in a previous failed site (n = 12) were included. To date, peri-implantitis is the main reason for late implant failure (81.9%). Trephine burs seem to be the best-known method for implant removal. Nevertheless, the counter-torque-ratchet-technique, because of the low invasiveness, should be the first choice for the clinician. Regarding zirconia implant removal, only scarce data are available. Implantation in previously failed sites irrespective of an early or late failure results in 71% to 100% survival over 5 years. Conclusion: If removal is required, interventions should be based on considerations regarding minimally invasive access and management as well as predictable healing. (Post)Operative considerations should primarily depend on the defect type and the consecutive implantation plans.


Assuntos
Implantação Dentária/efeitos adversos , Implantes Dentários/efeitos adversos , Falha de Restauração Dentária , Remoção de Dispositivo/normas , Guias de Prática Clínica como Assunto , Implantação Dentária/instrumentação , Humanos , Fatores de Risco
19.
Braz. oral res. (Online) ; 33: e046, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1011657

RESUMO

Abstract: The aim of this systematic review was to investigate the association between the different factors of loading protocols and the long-term stability of micro-screws from biomechanical and histological viewpoints. Searches were performed on PubMed, Embase, Cochrane Library, Wanfang and CNKI databases for animal experiments comparing loading protocols and the long-term stability of micro-screws. Among 1011 detected papers, 16 studies met the eligibility criteria and were selected for analysis. Most studies showed medium methodological quality for evaluation of micro-screws' long-term stability. Five studies reported that loading would not destroy the long-term stability of micro-screws. Three studies indicated that low-intensity immediate loading or a 3-week minimal healing time was acceptable. Two studies reported that the loading magnitude was a controversial issue with regard to the micro-screws' long-term stability. Two studies suggested that counterclockwise loading could decrease the long-term stability of micro-screws. In conclusion, immediate loading below 100g force, healing time greater than 3 weeks, regular loading below 200g force and a clockwise direction of force supported the long-term stability of micro-screws. Further studies relating to the combination of varying loading conditions will be needed.


Assuntos
Animais , Parafusos Ósseos/normas , Implantes Dentários/normas , Implantação Dentária/métodos , Procedimentos de Ancoragem Ortodôntica/métodos , Valores de Referência , Fatores de Tempo , Cicatrização , Fenômenos Biomecânicos , Reprodutibilidade dos Testes , Resultado do Tratamento , Modelos Animais , Implantação Dentária/instrumentação , Desenho de Equipamento , Procedimentos de Ancoragem Ortodôntica/instrumentação
20.
Dental Press J Orthod ; 23(5): 93-101, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30427498

RESUMO

INTRODUCTION: Rapid maxillary expansion (RME) is the therapy of choice to correct skeletal transverse dimension in children and adolescents, associating orthopedic and dental effects. In an attempt to prevent the undesirable dentoalveolar effects and optimize the potential of skeletal expansion in individuals in advanced stages of skeletal maturation, the miniscrew-assisted rapid palatal expander (MARPE) was proposed by Lee et al. in 2010. OBJECTIVE: This paper presents a systematized protocol for selection of miniscrews indicated for MARPE, by the evaluation of cone-beam computed tomographies (CBCT). Variables related with the bone and soft tissue thicknesses at the palatal regions of interest, as well as in relation to the fixation rings of miniscrews of the palatal expander are analyzed and discussed to provide better performance in the clinical practice.


Assuntos
Parafusos Ósseos , Má Oclusão/terapia , Procedimentos de Ancoragem Ortodôntica/métodos , Técnica de Expansão Palatina , Protocolos Clínicos , Tomografia Computadorizada de Feixe Cônico , Técnica de Fundição Odontológica , Implantação Dentária/instrumentação , Implantação Dentária/métodos , Humanos , Má Oclusão/diagnóstico por imagem , Procedimentos de Ancoragem Ortodôntica/instrumentação , Técnica de Expansão Palatina/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA