Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
J Vet Cardiol ; 53: 52-59, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38688090

RESUMO

Transcatheter pulmonary valve implantation (TPVI) is indicated for use in the management of failing pulmonary valves in humans. We report here the long-term follow-up of the first documented transcatheter pulmonary valve implanted in a client-owned dog. A one-year-old Beagle dog with severe congenital type A valvular pulmonic stenosis first underwent percutaneous balloon pulmonary valvuloplasty, leading two years later to severe pulmonary regurgitation. A TPVI using a Melody™ bioprosthetic valve was then successfully performed, with normalization of the right heart cavities. Repeated two- and three-dimensional transthoracic echocardiographic examinations combined with Doppler modes confirmed the appropriate position and function of the valve for four years. Mitral myxomatous valvular degeneration led to refractory left-sided congestive heart failure, and the dog was humanely euthanized. After postmortem examination, X-ray imaging and histopathological evaluation of the stent and the valve were performed. Ex-vivo imaging of the implanted valve using a Faxitron® Path radiography system and microscopic evaluation of the implanted stent and bioprosthetic leaflets did not show any relevant leaflet or stent alterations. This case provides a proof of concept in interventional veterinary cardiology, showing that TPVI can be performed in dogs with subsequent long-term maintaining normal pulmonary valve function.


Assuntos
Doenças do Cão , Implante de Prótese de Valva Cardíaca , Estenose da Valva Pulmonar , Valva Pulmonar , Animais , Cães , Doenças do Cão/cirurgia , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/patologia , Estenose da Valva Pulmonar/veterinária , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/patologia , Implante de Prótese de Valva Cardíaca/veterinária , Implante de Prótese de Valva Cardíaca/instrumentação , Ecocardiografia Tridimensional/veterinária , Insuficiência da Valva Pulmonar/veterinária , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Ecocardiografia/veterinária , Bioprótese/veterinária , Masculino , Próteses Valvulares Cardíacas/veterinária , Feminino
2.
Vet Clin North Am Small Anim Pract ; 53(6): 1343-1352, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37798048

RESUMO

Both open surgical repair and a hybrid-interventional option are now available for mitral valve repair (MVR) at select veterinary centers worldwide, making the need for awareness of options and the intricacies around case selection of increasing importance. This article will overview both options currently available and their current stages of progress.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Animais , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/veterinária , Implante de Prótese de Valva Cardíaca/veterinária , Resultado do Tratamento
3.
J Vet Cardiol ; 26: 10-18, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31785529

RESUMO

Transcatheter pulmonary valve (TPV) implantation is a therapeutic approach approved by the United States Food and Drug Administration for human patients with failing pulmonary conduits in 2010 and for failing bioprosthetic surgical pulmonary valves in 2017. We report here the first successful transcatheter implantation of a stented valve in a pulmonary position in a dog with congenital pulmonary valve disease. A 3-year-old, 10.9 kg, client-owned Beagle dog was referred for a follow-up visit after a percutaneous balloon valvuloplasty performed 22 months before for treatment of a severe type A valvular pulmonary stenosis. The Doppler-derived peak pressure gradient was 348 mmHg before the procedure and 66 mmHg 24 h after. The dog was lethargic. Echocardiography revealed a mild pulmonary stenosis (pressure gradient-43 mmHg), severe pulmonary regurgitation, and secondary severe right ventricular and right atrial dilation. Worsening of right heart dilation was observed 2 months later despite medical therapy. A TPV implantation was performed using a prestented Melody bovine jugular bioprosthetic valve. The dog recovered uneventfully and was discharged 10 days after the procedure. Right heart dilation resolved within 15 days. The dog was doing well 7 months after valve implantation. This case demonstrates that TPV implantation with a stented valve is technically feasible in dogs with severe pulmonary valve disease. Stringent postoperative care, with particular attention to thrombosis and infectious endocarditis, and appropriate sizing and positioning of the valve stent are keys to the success of this procedure.


Assuntos
Cateteres Cardíacos/veterinária , Doenças do Cão/cirurgia , Implante de Prótese de Valva Cardíaca/veterinária , Próteses Valvulares Cardíacas/veterinária , Insuficiência da Valva Pulmonar/veterinária , Animais , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/veterinária , Doenças do Cão/diagnóstico por imagem , Cães , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia
5.
Artigo em Inglês | MEDLINE | ID: mdl-28106960

RESUMO

Left ventricular assist device implantation disrupts the natural intracavitary blood flow path through the heart, introducing flow patterns potentially associated with thrombosis, especially around the inflow cannula. We describe a novel technique for completely excluding the left ventricle with an assist device by using a cone shaped ring-reinforced prosthesis.


Assuntos
Insuficiência Cardíaca/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Animais , Bovinos , Insuficiência Cardíaca/veterinária , Implante de Prótese de Valva Cardíaca/veterinária , Suínos , Resultado do Tratamento
7.
J Vet Cardiol ; 14(1): 185-92, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22366571

RESUMO

Prognosis for dogs with severe mitral regurgitation is poor with medical therapy alone. Open surgical mitral valve repair consisting of circumferential mitral annuloplasty and artificial chordal replacement confers durability and improved long-term clinical outcome without a need for long-term antithrombotic therapies. This approach has been successfully used in canine patients, including small-breed dogs. Methods for mitral valve repair applicable to small dogs are described.


Assuntos
Doenças do Cão/cirurgia , Insuficiência da Valva Mitral/veterinária , Animais , Ponte Cardiopulmonar/métodos , Ponte Cardiopulmonar/veterinária , Cães , Implante de Prótese de Valva Cardíaca/veterinária , Insuficiência da Valva Mitral/cirurgia
8.
J Invest Surg ; 24(5): 222-6, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21867392

RESUMO

BACKGROUND: The purpose of this study was to define an experimental model and a reproducible surgical technique for the preclinical assessment of safety and biocompatibility of a novel intra-annular internal aortic annulus repair device. METHODS: Adult sheep were implanted with HAART Inc's 19 mm aortic annulus repair device via a transverse aortotomy using standard anesthetic, surgical, and cardiopulmonary bypass techniques. Animals were closely monitored throughout the study period until the time of elective sacrifice at 30 or 60 days. RESULTS: Six adult sheep, mean age 63.2 weeks, mean weight 68.8 kg, underwent aortic annuloplasty with a 19 mm annuloplasty frame. Five of the sheep remained stable until scheduled sacrifice. The primary outcome of this study was animal mortality. Early mortality was seen in only one animal (16.7%), due to a surgical complication. Mild-to-moderate aortic insufficiency was observed in all animals upon echocardiographic examination at the time of elective sacrifice. CONCLUSIONS: Of the six animals that underwent aortic annuloplasty, there was one early death due to surgical complication. The remaining five subjects were clinically stable at the time of elective sacrifice. Any conclusions regarding the cause of the observed aortic insufficiency are beyond the scope of this feasibility study but would need to be fully evaluated in the preclinical assessment of any internal aortic annuloplasty device. We have shown that we have developed a reproducible surgical technique in a physiologically appropriate model for the preclinical assessment of internal aortic annulus repair devices.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Animais , Insuficiência da Valva Aórtica/cirurgia , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/veterinária , Masculino , Ovinos/cirurgia , Resultado do Tratamento
9.
J Vet Cardiol ; 13(2): 91-9, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21640677

RESUMO

OBJECTIVE: To describe the surgical technique and report outcome of dogs undergoing bioprosthesis valve replacement for severe tricuspid regurgitation (TR) secondary to congenital tricuspid valve dysplasia (TVD). ANIMALS, MATERIALS AND METHODS: Twelve client-owned dogs (19-43 kg) with TVD underwent tricuspid valve replacement with a bovine pericardial or porcine aortic bioprosthesis with the aid of cardiopulmonary bypass. Anticoagulation with warfarin was maintained for 3 months after surgery and then discontinued. RESULTS: Ten of 12 (83.3%) dogs survived surgery and were discharged from the hospital. Seven dogs were alive with complete resolution of TR for a median period of 48 months (range 1-66 months) after surgery. Two dogs underwent euthanasia because of bioprosthesis failure due to inflammatory pannus at 10 and 13 months after surgery. Two dogs experienced valve thrombosis that was resolved by tissue plasminogen activator. One dog developed suspected endocarditis after surgery that was resolved with antibiotics. Serious cardiac complications included atrial fibrillation and flutter, right-to-left shunt through an uncorrected patent foramen ovale, complete atrioventricular block, and sudden cardiac arrest. Postoperative atrial fibrillation or flutter did not occur in 7 dogs treated prophylactically with oral amiodarone before surgery. CONCLUSIONS: Curative intermediate-term outcomes are possible in dogs undergoing open tricuspid valve replacement with a bioprosthesis. Prosthesis-related complications include inflammatory pannus, thrombosis, and endocarditis. Postoperative atrial fibrillation or flutter can be reduced or prevented by prophylactic preoperative treatment with amiodarone. Several identified complications are avoidable or can be reduced with increased awareness and experience with these techniques.


Assuntos
Bioprótese/veterinária , Doenças do Cão/cirurgia , Implante de Prótese de Valva Cardíaca/veterinária , Próteses Valvulares Cardíacas/veterinária , Insuficiência da Valva Tricúspide/veterinária , Valva Tricúspide/cirurgia , Animais , Doenças do Cão/congênito , Cães , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Masculino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/veterinária , Resultado do Tratamento , Valva Tricúspide/anormalidades , Insuficiência da Valva Tricúspide/congênito , Insuficiência da Valva Tricúspide/cirurgia
10.
Vet Surg ; 36(3): 190-8, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17461942

RESUMO

OBJECTIVES: To describe an open, beating heart surgical technique and use of a bovine pericardial prosthetic valve for mitral valve replacement (MVR) in the dog. STUDY DESIGN: Clinical case report. ANIMALS: Male Bull Terrier (17-month-old, 26 kg) with mitral valve dysplasia and severe regurgitation. METHODS: A bovine pericardial bioprosthesis was used to replace the mitral valve using an open beating heart surgical technique and cardiopulmonary bypass. RESULTS: Successful MVR was achieved using a beating heart technique. Mitral regurgitation resolved and cardiac performances improved (left ventricular end-diastolic diameter decreased from 57.6 to 48.7 mm, and left atrium/aorta ratio returned to almost normal, from 1.62 to 1.19). Cardiopulmonary by-pass time and total surgical duration were decreased compared with standard cardioplegic techniques. Surgical recovery was uneventful and on echocardiography 6 months later valve function was excellent. CONCLUSION: Considering the technique advantages (no cardiac arrest, ischemic reperfusion injury, and hypothermia, or the need for aortic dissection and cannulation for administration of cardioplegic solution), short-term mortality and morbidity may be reduced compared with standard cardioplegic techniques. CLINICAL RELEVANCE: Based on experience in this dog, beating heart mitral valvular replacement is a seemingly safe and viable option for the dog and bovine pericardial prosthesis may provide better long-term survival than mechanical prostheses.


Assuntos
Bioprótese/veterinária , Doenças do Cão/cirurgia , Implante de Prótese de Valva Cardíaca/veterinária , Próteses Valvulares Cardíacas/veterinária , Estenose da Valva Mitral/veterinária , Valva Mitral , Pericárdio/transplante , Animais , Bovinos , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/patologia , Cães , Masculino , Estenose da Valva Mitral/cirurgia , Ultrassonografia
11.
Rev. colomb. cienc. pecu ; 19(4): 415-425, dic. 2006. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-462968

RESUMO

En el ámbito mundial, las investigaciones sobre la patología valvular porcina se limitan casi enteramente a la válvula mitral y existe muy poca información sobre alteraciones   de la válvula aórtica. Las válvulas aórticas porcinas son utilizadas comúnmente como bioimplantes en humanos. Por esta razón en este estudio se propusieron los siguientes objetivos: caracterizar la patología valvular aórtica en cerdos seleccionados para la elaboración de bioprótesis valvulares cardíacas, discutir los mecanismos involucrados en el desarrollo de dichas lesiones y analizar los criterios de selección para determinar la confiabilidad del implante. Para esto se recolectaron al azar 50 corazones con lesiones evidentes de la válvula aórtica y 50 sin lesiones evidentes. Las válvulas se procesaron por el método histopatológico de rutina y se realizaron las tinciones de Hematoxilina-Eosina y azul alciano-PAS. Los resultados se evaluaron mediante estadística descriptiva e inferencia estadística; además, se realizó un análisis mediante la prueba de Chi-cuadrado utilizando el programa SPSS versión 1.0 para determinar asociaciones entre las variables macroscópicas y microscópicas. Las lesiones microscópicas y su frecuencia en los dos grupos estudiados fueron, respectivamente, las siguientes: trastornos vasculares 84 por ciento y 38 por ciento; endocardiosis 80 por ciento y 4 por ciento; fenestraciones 48 por ciento, únicamente en las que tenían lesiones obvias; valvulitis 42 por ciento y 24 por ciento. Se presentan y se correlacionan las principales alteraciones macro y microscópicas; así como los posibles mecanismos implicados en su desarrollo. Este estudio es el primero, en Colombia, que caracteriza las alteraciones patológicas de la válvula aórtica porcina.


Assuntos
Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca/veterinária , Patologia Veterinária , Suínos , Transplantes/veterinária
12.
J Am Vet Med Assoc ; 226(9): 1508-11, 1500, 2005 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-15882001

RESUMO

Eight dogs with naturally occurring severe mitral regurgitation underwent mitral valve replacement with a mechanical valve prosthesis during cardiopulmonary bypass. Dogs received warfarin orally after surgery to maintain a prothrombin time-based international normalized ratio from 2.5 to 3.5. Seven dogs survived surgery. Left ventricular diastolic volume index decreased significantly from 206 +/- 91 mL/m2 before surgery to 121 +/- 47 mL/m2 after surgery. Left atrium-to-aorta ratio decreased significantly from 2.66 +/- 0.4 before surgery to 1.73 +/- 0.65 after surgery. Left ventricular systolic volume index was not significantly different after surgery (56 +/- 36 mL/m2), compared with before surgery (40 +/- 32 mL/m2). Median survival after surgery was 4.5 months (range, 0.75 months to 5.25 years). Six dogs died of confirmed or suspected thrombosis of the valve prosthesis. Dogs with severe mitral regurgitation tolerated mitral valve replacement well, but a high incidence of prosthetic valve thrombosis limited long-term outcome.


Assuntos
Doenças do Cão/cirurgia , Implante de Prótese de Valva Cardíaca/veterinária , Próteses Valvulares Cardíacas/veterinária , Insuficiência da Valva Mitral/veterinária , Valva Mitral , Animais , Anticoagulantes/administração & dosagem , Doenças do Cão/mortalidade , Cães , Implante de Prótese de Valva Cardíaca/mortalidade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/cirurgia , Cirurgia Veterinária/instrumentação , Cirurgia Veterinária/métodos , Análise de Sobrevida , Trombose/etiologia , Trombose/mortalidade , Trombose/veterinária , Resultado do Tratamento , Varfarina/administração & dosagem
13.
Contemp Top Lab Anim Sci ; 39(5): 20-5, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11040870

RESUMO

Increased use of the ovine animal model in cardiovascular surgical research has created a salient need for standardized echocardiography techniques. To demonstrate a reproducible image in this species and confirm the validity of echocardiography as a diagnostic tool, we implanted 10 sheep with a pulmonary valve homograft and monitored them through weekly echocardiographic examinations until 20 weeks after implantation. We obtained good images from the left cranial and the left caudal transducer windows without needing to sedate the animals. Sedated sheep yielded adequate views from the right apical window. Echocardiographic data on the implanted homografts (including functional capacity, presence of calcification, and hemodynamic information and measurements), completely agreed with the results of the post-explantation examinations.


Assuntos
Ecocardiografia Doppler em Cores/veterinária , Implante de Prótese de Valva Cardíaca/veterinária , Valva Pulmonar/cirurgia , Ovinos/cirurgia , Animais , Modelos Animais de Doenças , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Masculino , Valva Pulmonar/fisiologia , Reprodutibilidade dos Testes , Ovinos/fisiologia
14.
Contemp Top Lab Anim Sci ; 39(4): 43-6, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11487230

RESUMO

A female Dorset-cross sheep developed labored respirations and was anorexic, weak, ataxic and febrile (42.0 degrees C) 15 days after implantation of a cardiac device. Clinical pathologic evaluation identified a mild leukocytosis (11,800 cells/microl), neutrophilia (8,969 cells/microl), and hypokalemia (2.9 mmol/L). Despite intensive therapy, the animal was euthanized 7 days later. Necropsy of the sheep revealed meningitis and vegetative endocarditis associated with the cardiac device. Blood cultures collected antemortem and tissue cultures collected at necropsy yielded Streptococcus suis. Histopathology confirmed the diagnosis of bacterial valvular endocarditis and meningoencephalitis. A variety of environmental and host factors are proposed as contributing to the infection, and the zoonotic potential of S. suis is discussed.


Assuntos
Endocardite Bacteriana/veterinária , Implante de Prótese de Valva Cardíaca/veterinária , Próteses Valvulares Cardíacas/efeitos adversos , Meningites Bacterianas/veterinária , Doenças dos Ovinos/microbiologia , Infecções Estreptocócicas/veterinária , Streptococcus suis/patogenicidade , Animais , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/patologia , Feminino , Próteses Valvulares Cardíacas/microbiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Meningites Bacterianas/etiologia , Meningites Bacterianas/patologia , Ovinos , Doenças dos Ovinos/etiologia , Doenças dos Ovinos/patologia , Infecções Estreptocócicas/etiologia , Infecções Estreptocócicas/patologia , Streptococcus suis/isolamento & purificação
15.
ASAIO J ; 43(5): M382-6, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9360066

RESUMO

Clotting mechanisms, the coagulation cascade, platelet function, and platelet-leukocyte-endothelial cell interactions are all very similar in humans and pigs. Because of these similarities, the authors concluded that the pig would be an ideal model for the study of thromboembolism resulting from prosthetic heart valves. To date, they have successfully recovered a total of 11 pigs (52.9 +/- 8.1 kg), 3 with bioprosthetic valves and 8 with mechanical valves, all in the mitral position (25 mm od). The normal presence of high numbers of pulmonary endothelial macrophages and other unique aspects of porcine cardiovascular and pulmonary function dictate somewhat different surgical protocols than those normally used for human patients and ruminant species. Some of these special procedures include 1) crystalloid prime without the use of plasma volume expanders, especially those with a starch base; 2) pharmacologic protection against arrhythmias (lidocaine, 4 mg/kg); 3) special attention to adequate hypothermic cardioprotection during the time of cross-clamp; 4) the use of shock doses of corticosteroid (prednisolone sodium succinate, 0.5 mg/kg) before removal of the aortic cross-clamp; and 5) positive inotropic support (dopamine, 0.008 mg/kg) while weaning from cardiopulmonary bypass. Gamma camera images of 111In tagged autologous platelets 24 hours after surgery show most thrombi located on the sewing ring with fewer on the pledgets and anchor sutures. The latter observations were confirmed by quantification of platelet deposition using a gamma counter.


Assuntos
Bioprótese/veterinária , Implante de Prótese de Valva Cardíaca/veterinária , Valva Mitral , Suínos/cirurgia , Animais , Bioprótese/efeitos adversos , Plaquetas/fisiologia , Modelos Animais de Doenças , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Próteses Valvulares Cardíacas/veterinária , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Radioisótopos de Índio , Masculino , Valva Mitral/patologia , Adesividade Plaquetária , Tromboembolia/etiologia , Tromboembolia/patologia , Tromboembolia/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA