RESUMO
BACKGROUND: A laser-induced needle-free microjet injector was developed for rapid, high-speed drug delivery of microliters into the skin. OBJECTIVE: This study evaluated the clinical rejuvenation effect of repeated dermal injections of the collagen simulator poly- dl -lactic acid (PDLA) using a laser-induced needle-free microjet injector. METHODS: Five PDLA injection sessions using a laser-induced needle-free microjet injector were conducted in patients concerned about aging skin. Facial uplifting, darkness, redness, roughness, pore size, subjective satisfaction, and side effects were evaluated before each session and 4 weeks after treatment completion. Histological evaluation was also performed with immunohistochemical staining of collagen and elastic fibers. RESULTS: The clinical results of 27 female patients were evaluated. The treatment resulted in a noticeable skin surface uplifting (0.711 ± 0.42 mm) and significant improvements in darkness ( p = .013), redness ( p = .009), and roughness ( p = .036), with no significant difference in the pore size ( p = .770). Patients were reported being satisfied with the overall therapeutic effects, despite mild and tolerable adverse effects. Histological findings revealed growth and thickening of collagen and elastic fibers, with marked increase in collagen I and III levels. CONCLUSION: Repeated dermal injections of PDLA using a laser-induced microjet injector offer excellent drug delivery, achieving high efficacy in skin rejuvenation, patient satisfaction, and safety.
Assuntos
Técnicas Cosméticas , Satisfação do Paciente , Poliésteres , Rejuvenescimento , Envelhecimento da Pele , Humanos , Feminino , Envelhecimento da Pele/efeitos dos fármacos , Poliésteres/administração & dosagem , Pessoa de Meia-Idade , Técnicas Cosméticas/instrumentação , Adulto , Face , Idoso , Polímeros/administração & dosagem , Injeções Intradérmicas/instrumentação , Ácido Láctico/administração & dosagem , Lasers , Preenchedores Dérmicos/administração & dosagemRESUMO
OBJECTIVE: An accuracy test method is proposed to reduce the amount of reagents used in the test and reduce the cost of spot checks and self-tests. METHODS: According to the requirements of dose accuracy test in standard atmospheric conditions in ISO 11608-1:2014, dose accuracy test is carried out for the same batch of reusable pen injector samples by using the test method proposed in this paper and the test method in relevant foreign research, and the data measured by the two methods are processed. RESULTS: After experimental testing and analysis, the data measured by the two methods did not exceed the dose accuracy limit specified in the ISO standard. There was no significant difference between the two methods when the dose of 60 U and 30 U were tested, but there was significant difference when the dose of 1 U was tested. CONCLUSIONS: Both methods can be used to evaluate dose accuracy, however, the method proposed in this paper can reduce the usage of drugs by 2/3, so it can reduce cost of supervised test.
Assuntos
Equipamentos Descartáveis/normas , Injeções Intradérmicas/instrumentação , Segurança de Equipamentos , SeringasAssuntos
Técnicas Cosméticas , Preenchedores Dérmicos/administração & dosagem , Poliésteres/administração & dosagem , Envelhecimento da Pele , Pele/efeitos dos fármacos , Parede Abdominal , Adulto , Idoso , Braço , Nádegas , Cânula , Estética , Feminino , Humanos , Injeções Intradérmicas/instrumentação , Injeções Intradérmicas/métodos , Pessoa de Meia-Idade , Agulhas , Coxa da Perna , Resultado do TratamentoRESUMO
In this study the effect of repeated-fractional intradermal administration of diphtheria toxoid (DT) compared to a single administration in the presence or absence of adjuvants formulated in dissolving microneedles (dMNs) was investigated. Based on an adjuvant screening with a hollow microneedle (hMN) system, poly(I:C) and gibbsite, a nanoparticulate aluminum salt, were selected for further studies: they were co-encapsulated with DT in dMNs with either a full or fractional DT-adjuvant dose. Sharp dMNs were prepared regardless the composition and were capable to penetrate the skin, dissolve within 20 min and deposit the intended antigen-adjuvant dose, which remained in the skin for at least 5 h. Dermal immunization with hMN in repeated-fractional dosing (RFrD) resulted in a higher immune response than a single-full dose (SFD) administration. Vaccination by dMNs led overall to higher responses than hMN but did not show an enhanced response after RFrD compared to a SFD administration. Co-encapsulation of the adjuvant in dMNs did not increase the immune response further. Immunization by dMNs without adjuvant gave a comparable response to subcutaneously injected DT-AlPO4 in a 15 times higher dose of DT, as well as subcutaneous injected DT-poly(I:C) in a similar DT dose. Summarizing, adjuvant-free dMNs showed to be a promising delivery tool for vaccination performed in SFD administration.
Assuntos
Toxoide Diftérico/administração & dosagem , Sistemas de Liberação de Medicamentos/métodos , Microinjeções/métodos , Agulhas , Uso Off-Label , Vacinação/métodos , Adjuvantes Imunológicos/administração & dosagem , Adjuvantes Imunológicos/metabolismo , Animais , Toxoide Diftérico/metabolismo , Relação Dose-Resposta a Droga , Sistemas de Liberação de Medicamentos/instrumentação , Avaliação Pré-Clínica de Medicamentos/métodos , Feminino , Humanos , Injeções Intradérmicas/instrumentação , Injeções Intradérmicas/métodos , Camundongos , Camundongos Endogâmicos BALB C , Microinjeções/instrumentação , Pele/efeitos dos fármacos , Pele/metabolismo , Vacinação/instrumentaçãoRESUMO
BACKGROUND: Melasma is a difficult to treat pigmentation disorder. However, some successes have been attained by microneedling. The aim of the present study was to evaluate the efficacy of microneedling using meso-depigmentation solution (mesoneedling) in comparison with standard microneedling, over a 4-month treatment period. METHODS: As a part of this pilot study, 20 patients received microneedling on one side and mesoneedling on another side of their face. Treatment was repeated on a monthly basis for 4 months. Treatment efficacy was defined through Dermacatch® colorimetry, modified Melasma Area and Severity (mMASI) score determination, Investigator's Global Assessment (IGA), and patient questionnaires, whereby all assessments were conducted at the baseline, as well after 2 and 4 months of treatment. RESULTS: Before treatments, mean difference between pigmented and normal skin calculated by Dermacatch® was 43.7 ± 20.12 and 44.6 ± 20.72 in microneedling sides and mesoneedling sides, respectively. After two and four sessions, these values declined to 34.5 ± 16.26 and 28.05 ± 13.79 on the side subjected to microneedling, while 29.75 ± 15.07 and 20.45 ± 10.58 were measured on the mesoneedling side. Statistically significant differences have been observed between microneedling and mesoneedling treatments at both time points (P = .0001, P = .0001). The mMASI scores obtained upon treatment completion were significantly lower on both the microneedling and the mesoneedling side. The IGA and patients' self-assessment scores further confirmed that both treatments were effective in treating melasma, without producing any notable side-effects or complications. CONCLUSION: In sum, both microneedling and mesoneedling are effective in decreasing melanin content in the epidermal melasma lesions.
Assuntos
Técnicas Cosméticas/efeitos adversos , Agulhamento Seco/métodos , Melanose/terapia , Preparações Clareadoras de Pele/administração & dosagem , Adolescente , Adulto , Terapia Combinada/efeitos adversos , Terapia Combinada/instrumentação , Terapia Combinada/métodos , Técnicas Cosméticas/instrumentação , Agulhamento Seco/efeitos adversos , Agulhamento Seco/instrumentação , Face , Feminino , Humanos , Injeções Intradérmicas/efeitos adversos , Injeções Intradérmicas/instrumentação , Injeções Intradérmicas/métodos , Masculino , Melanose/diagnóstico , Pessoa de Meia-Idade , Agulhas/efeitos adversos , Projetos Piloto , Índice de Gravidade de Doença , Resultado do Tratamento , Adulto JovemRESUMO
BACKGROUND: Diluted/hyperdiluted calcium hydroxylapatite (CaHA) represents an emerging biostimulatory treatment. However, limited data concerning the effects of this agent on the face have been provided so far. OBJECTIVE: To investigate the efficacy and safety of hyperdiluted CaHA 1:2 treatment for mid and lower face rejuvenation. PATIENTS AND METHODS: A retrospective study of 40 patients seeking skin rejuvenation for mid and lower face, treated with hyperdiluted CaHA 1:2 technique at baseline (T0), was performed. Patients were classified according to validated scales of aging in the mid to lower face at T0 and efficacy was established with scales calculated again at 4-month post-treatment (T1). In addition, efficacy was assessed by blinded evaluation of T0/T1 clinical pictures, non-invasive skin imaging and patient satisfaction. Safety was assessed through pain scale and minor/major adverse events. RESULTS: Hyperdiluted CaHA 1:2 successfully decreased aging severity scores of the mid and lower face. Variations of collagen morphology and increased vessel density at T1 were observed with noninvasive skin imaging. Most patients were very satisfied. Mean pain score was low and only minor adverse events were reported. CONCLUSION: Hyperdiluted CaHA 1:2 technique seems to be effective and safe for mid and lower face skin rejuvenation.
Assuntos
Materiais Biocompatíveis/administração & dosagem , Técnicas Cosméticas/efeitos adversos , Durapatita/administração & dosagem , Satisfação do Paciente , Envelhecimento da Pele/efeitos dos fármacos , Adulto , Idoso , Materiais Biocompatíveis/efeitos adversos , Cânula , Técnicas Cosméticas/instrumentação , Durapatita/efeitos adversos , Face , Feminino , Humanos , Injeções Intradérmicas/instrumentação , Masculino , Pessoa de Meia-Idade , Rejuvenescimento , Estudos Retrospectivos , Resultado do TratamentoRESUMO
Mycobacterial diseases are important health issues in farmed deer. The single intradermal tuberculin test is the standard test for tuberculosis testing in deer. We studied two factors which might influence the response of deer to skin testing: the inoculation site and the injection device. Deer included in this study were 2.5 years old farmed red deer (Cervus elaphus) hinds (nâ¯=â¯80). Two areas of 3â¯cmâ¯×â¯3â¯cm were shaved at the left side of the neck. Site A (SA) was situated about 10â¯cm caudal to the head, while site B (SB) was 10â¯cm caudal to SA. All hinds received at the same time two 0.1â¯ml inoculations of Mycobacterium avium derived purified protein derivative (aPPD). One inoculation was made by syringe and the other one with the needle-free syringe Dermojet. To test the inoculation site effect, half of the animals were inoculated by Dermojet in SA and by syringe in SB to compare with the inoculation in SA by syringe and Dermojet in SB in the other half. No differences were recorded for the injection device nor for the inoculation site. Ten hinds had a skinfold increase larger than 30 tenths of mm by any injection device and inoculation site. Seven (9%) and 6 (8%) hinds were classified as positive by syringe and Dermojet, and at the anterior or posterior inoculation site, respectively. The distribution of skinfold thickness increases did not differ by injection device. Our findings support the needle-free Dermojet syringe as a suitable tool for skin-testing in red deer and suggest no relevant effect of the position of the inoculation site along the neck in red deer.
Assuntos
Cervos , Injeções Intradérmicas/métodos , Mycobacterium avium/fisiologia , Teste Tuberculínico/veterinária , Tuberculina/farmacologia , Tuberculose/veterinária , Animais , Feminino , Injeções Intradérmicas/instrumentação , Tuberculose/diagnósticoRESUMO
In the twenty-first century, microneedles based drug delivery is drawing attention worldwide in the research due to current signs of progress in the controlled release drug delivery through microneedles. The microneedles represent a promising technology to deliver therapeutic compounds into the skin for chronic complications like osteoporosis, diabetes, cancer and induction of immune responses from protein and DNA vaccines. However, the delivery of hydrophilic drugs and macromolecular agents are challenging. In this write up authors included the meticulous illustration of the chronological development of fabrication of microneedles with respect to an assortment of techniques, their modifications, clinical trials and regulatory perspectives period of 2000-2019. This review summarizes characterization, fabrications, biological applications and challenges. Additionally, relevant patents based on microneedle from USPTO) database are also highlighted.
Assuntos
Vacinas Anticâncer/uso terapêutico , Diabetes Mellitus/tratamento farmacológico , Sistemas de Liberação de Medicamentos/métodos , Agulhas , Neoplasias/tratamento farmacológico , Osteoporose/tratamento farmacológico , Vacinas de DNA/uso terapêutico , Sistemas de Liberação de Medicamentos/instrumentação , Humanos , Injeções Intradérmicas/instrumentação , Injeções Intradérmicas/métodosRESUMO
Minimally invasive devices to detect molecules in dermal interstitial fluid (ISF) are desirable for point-of-care diagnostic and monitoring applications. In this study, we developed a microneedle (MN) patch that collects ISF for on-patch biomarker analysis by surface-enhanced Raman scattering (SERS). The micrometer-scale MNs create micropores in the skin surface, through which microliter quantities of ISF are collected onto plasmonic paper on the patch backing. The plasmonic paper was prepared by immobilizing poly(styrenesulfonate) (PSS) coated gold nanorods (AuNRs) on a thin strip of filter paper using plasmonic calligraphy. Negatively charged PSS was used to bind positively charged rhodamine 6G (R6G), which served as a model compound, and thereby localize R6G on AuNR surface. R6G bound on the AuNR surface was detected and quantified by acquiring SERS spectra from the plasmonic paper MN patch. This approach was used to measure pharmacokinetic profiles of R6G in ISF and serum from rats in vivo. This proof-of-concept study indicates that a plasmonic paper MN patch has the potential to enable on-patch measurement of molecules in ISF for research and future medical applications.
Assuntos
Derme/química , Líquido Extracelular/química , Agulhas , Papel , Rodaminas/análise , Animais , Feminino , Ouro/química , Injeções Intradérmicas/instrumentação , Injeções Intradérmicas/métodos , Nanotubos/química , Testes Imediatos , Poliestirenos/química , Estudo de Prova de Conceito , Ratos , Rodaminas/sangue , Rodaminas/farmacocinética , Análise Espectral Raman/métodosRESUMO
Minimally invasive point-of-care diagnostic devices are of great interest for rapid detection of biomarkers in diverse settings. Although blood is the most common source of biomarkers, interstitial fluid (ISF) is an alternate body fluid that does not clot or contain red blood cells that often complicate analysis. However, ISF is difficult to collect. In this study, we assessed the utility of a microneedle patch to sample microliter volumes of ISF in a simple and minimally invasive manner. We demonstrated the use of ISF collected in this way for therapeutic drug monitoring by showing similar vancomycin pharmacokinetic profiles in ISF and serum from rats. We also measured polio-specific neutralizing antibodies and anti-polio IgG in ISF similar to serum in rats immunized with polio vaccine. These studies demonstrate the potential utility of ISF collected by microneedle patch in therapeutic drug monitoring and immunodiagnostic applications.
Assuntos
Derme/metabolismo , Monitoramento de Medicamentos , Líquido Extracelular/metabolismo , Agulhas , Vancomicina , Animais , Anticorpos Neutralizantes/metabolismo , Anticorpos Antivirais/metabolismo , Biomarcadores/metabolismo , Monitoramento de Medicamentos/instrumentação , Monitoramento de Medicamentos/métodos , Feminino , Imunoglobulina G/metabolismo , Injeções Intradérmicas/instrumentação , Injeções Intradérmicas/métodos , Poliovirus/metabolismo , Vacinas contra Poliovirus/farmacologia , Ratos , Ratos Wistar , Vancomicina/farmacocinética , Vancomicina/farmacologiaRESUMO
The purpose of this study was to optimize the manufacturing of dissolving microneedles (dMNs) and to increase the antigen loading in dMNs to investigate the effect on their physicochemical properties. To achieve this, a novel single-array wells polydimethylsiloxane mold was designed, minimizing antigen wastage during fabrication and achieving homogeneous antigen distribution among the dMN arrays. Using this mold, hyaluronan (HA)-based dMNs were fabricated and tested for maximal ovalbumin (OVA) content. dMNs could be fabricated with an OVA:HA ratio as high as 1:1 (w/w), without compromising their properties such as shape and penetration into the ex vivo human skin, even after storage at high humidity and temperature. High antigen loading did not induce protein aggregation during dMN fabrication as demonstrated by complementary analytical methods. However, the dissolution rate in ex vivo human skin decreased with increasing antigen loading. About 2.7⯵g OVA could be delivered in mice by using a single array with an OVA:HA ratio of 1:3 (w/w). Intradermal vaccination with dMNs induced an immune response similar as subcutaneous injection and faster than after hollow microneedle injection. In conclusion, results suggest that (i) the polydimethylsiloxane mold design has an impact on the manufacturing of dMNs, (ii) the increase in antigen loading in dMNs affects the microneedle dissolution and (iii) dMNs are a valid alternative for vaccine administration over conventional injection.
Assuntos
Adjuvantes Imunológicos/administração & dosagem , Composição de Medicamentos/métodos , Sistemas de Liberação de Medicamentos/instrumentação , Vacinação/instrumentação , Vacinas/administração & dosagem , Adjuvantes Imunológicos/farmacocinética , Animais , Antígenos/administração & dosagem , Antígenos/imunologia , Dimetilpolisiloxanos/química , Sistemas de Liberação de Medicamentos/métodos , Liberação Controlada de Fármacos , Feminino , Humanos , Ácido Hialurônico/administração & dosagem , Ácido Hialurônico/imunologia , Ácido Hialurônico/farmacocinética , Imunogenicidade da Vacina/imunologia , Injeções Intradérmicas/instrumentação , Camundongos , Camundongos Endogâmicos BALB C , Microinjeções/instrumentação , Modelos Animais , Agulhas , Ovalbumina/administração & dosagem , Ovalbumina/imunologia , Ovalbumina/farmacocinética , Vacinação/métodos , Vacinas/imunologiaRESUMO
Infectious diseases propagated by arthropod vectors, such as tularemia, are commonly initiated via dermal infection of the skin. However, due to the technical difficulties in achieving accurate and reproducible dermal deposition, intradermal models are less commonly used. To overcome these limitations, we used microneedle arrays (MNAs), which are micron-scale polymeric structures, to temporarily disrupt the barrier function of the skin and deliver a bacterial inoculum directly to the dermis of an animal. MNAs increase reliability by eliminating leakage of the inoculum or blood from the injection site, thereby providing a biologically relevant model for arthropod-initiated disease. Here, we validate the use of MNAs as a means to induce intradermal infection using a murine model of tularemia initiated by Francisella novicida We demonstrate targeted delivery of the MNA bolus to the dermal layer of the skin, which subsequently led to innate immune cell infiltration. Additionally, F. novicida-coated MNAs were used to achieve lethality in a dose-dependent manner in C57BL/6 mice. The immune profile of infected mice mirrored that of established F. novicida infection models, consisting of markedly increased serum levels of interleukin-6 and keratinocyte chemoattractant, splenic T-cell depletion, and an increase in splenic granulocytes, together confirming that MNAs can be used to reproducibly induce tularemia-like pathogenesis in mice. When MNAs were used to immunize mice using an attenuated F. novicida mutant (F. novicida ΔlpxD1), all immunized mice survived a lethal subcutaneous challenge. Thus, MNAs can be used to effectively deliver viable bacteria in vivo and provide a novel avenue to study intradermally induced microbial diseases in animal models.
Assuntos
Francisella/patogenicidade , Injeções Intradérmicas/instrumentação , Agulhas , Pele/microbiologia , Tularemia/prevenção & controle , Animais , Anticorpos Antibacterianos/sangue , Vacinas Bacterianas/administração & dosagem , Vacinas Bacterianas/imunologia , Derme/imunologia , Derme/microbiologia , Modelos Animais de Doenças , Feminino , Imunização/instrumentação , Imunização/métodos , Interleucina-6/sangue , Camundongos , Camundongos Endogâmicos C57BL , Mutação , Reprodutibilidade dos Testes , Pele/imunologia , Baço/imunologia , Tularemia/imunologia , Vacinas Atenuadas/administração & dosagem , Vacinas Atenuadas/imunologiaRESUMO
BACKGROUND: The intradermal (ID) route for vaccination represents an effective alternative to subcutaneous (SC)/intramuscular administration to induce protective immunity. However, a critical issue associated with ID vaccination is the precise delivery of solution in the upper dermis, which ensures enhanced immunity. METHODS: We fabricated a hollow microneedle unit made of poly-glycolic acid by injection molding and bonding, and created a dedicated prototype injector. To ensure ID delivery of solution, the injected site was macroscopically and microscopically examined. Serum immunoglobulin G antibody production was measured by enzyme immunoassay and compared in groups of rats following either ID delivery with microneedles or SC administration with a 27-G stainless needle of graded vaccine doses. RESULTS: The unit used a tandem array of six microneedles, each with a side delivery hole, and a conduit inside for solution. Microneedles installed in the injector punctured the skin with the aid of a spring. Injection of solution formed a wheal due to ID distribution. Histologically, a wedge-shaped skin defect in the upper skin corresponded to each puncture site. Antibody titers following vaccinations on days 1 and 8 were significantly higher with ID injection than with SC delivery on day 15 and every 7 days thereafter until day 36 with mumps vaccination, and until day 36 with varicella vaccination. CONCLUSIONS: The microneedle unit presented here delivered solution intradermally without any difficulty and evoked antibody responses against viruses even with the reduced vaccine volume. Our findings confirm promising results of ID delivery as an immunogenic option to enhance vaccination efficacy.
Assuntos
Vacina contra Varicela/imunologia , Injeções Intradérmicas/instrumentação , Vacina contra Caxumba/imunologia , Agulhas , Vacinação/instrumentação , Animais , Anticorpos Antivirais/sangue , Vacina contra Varicela/administração & dosagem , Desenho de Equipamento , Imunoglobulina G/sangue , Injeções Subcutâneas , Masculino , Modelos Animais , Vacina contra Caxumba/administração & dosagem , Ácido Poliglicólico , Ratos , Ratos Sprague-DawleyRESUMO
PURPOSE: The force that has to be exerted on the plunger for administering a given amount of fluid in a given time, has an important influence on comfort for the subject and usability for the administrator in intradermal drug delivery. The purpose of this study is to model those forces that are subject-independent, by linking needle and syringe geometry to the force required for ejecting a given fluid at a given ejection rate. MATERIAL AND METHODS: We extend the well-known Hagen-Poiseuille formula to predict pressure drop induced by a fluid passing through a cylindrical body. The model investigates the relation between the pressure drop in needles and the theoretic Hagen-Poiseuille prediction and is validated in fifteen needles from 26G up to 33G suited for intradermal drug delivery. We also provide a method to assess forces exerted by operators in real world conditions. RESULTS: The model is highly linear in each individual needle with R-square values ranging from 75% up to 99.9%. Ten out of fifteen needles exhibit R-square values above 99%. A proof-of-concept for force assessment is provided by logging forces in operators in real life conditions. CONCLUSIONS: The force assessment method and the model can be used to pinpoint needle geometry for intradermal injection devices, tuning comfort for subjects and usability for operators.
Assuntos
Hidrodinâmica , Injeções Intradérmicas/instrumentação , Seringas , Ergonomia , AgulhasRESUMO
A fractional dose of inactivated poliovirus vaccine (fIPV) administered by the intradermal route delivers one fifth of the full vaccine dose administered by the intramuscular route and offers a potential dose-sparing strategy to stretch the limited global IPV supply while further improving population immunity. Multiple studies have assessed immunogenicity of intradermal fIPV compared with the full intramuscular dose and demonstrated encouraging results. Novel intradermal devices, including intradermal adapters and disposable-syringe jet injectors, have also been developed and evaluated as alternatives to traditional Bacillus Calmette-Guérin needles and syringes for the administration of fIPV. Initial experience in India, Pakistan, and Sri Lanka suggests that it is operationally feasible to implement fIPV vaccination on a large scale. Given the available scientific data and operational feasibility shown in early-adopter countries, countries are encouraged to consider introducing a fIPV strategy into their routine immunization and supplementary immunization activities.
Assuntos
Vacinação em Massa/economia , Vacinação em Massa/métodos , Vacina Antipólio de Vírus Inativado , Anticorpos Antivirais/imunologia , Criança , Pré-Escolar , Humanos , Imunização Secundária/economia , Imunização Secundária/métodos , Lactente , Injeções Intradérmicas/instrumentação , Injeções Intradérmicas/métodos , Vacinação em Massa/instrumentação , Poliovirus/imunologia , Vacina Antipólio de Vírus Inativado/administração & dosagem , Vacina Antipólio de Vírus Inativado/economia , Vacina Antipólio de Vírus Inativado/imunologia , Vacina Antipólio de Vírus Inativado/provisão & distribuiçãoRESUMO
Current methods for intradermal delivery of therapeutic products in clinical use include manual injection via the Mantoux technique and the use of injection devices, primarily developed for the delivery of vaccines and small molecules. A novel automated injection device is presented specifically designed for accurate delivery of multiple doses of product through a number of adjustable injection parameters, including injection depth, dose volume and needle insertion speed. The device was originally conceived for the delivery of a cell-based therapy to patients with skin wounds caused by epidermolysis bullosa. A series of preclinical studies was conducted (i) to evaluate the performance of the pre-production model (PreCTCDV01) and optimise the final design, (ii) to confirm that a cell therapy product can be effectively delivered through the injection system and (iii) to test whether the device can be safely and effectively operated by potential end-users. Results from these studies confirmed that the device is able to consistently deliver repeated doses of a liquid to the intradermal layer in an ex vivo skin model. In addition, the device can support delivery of a cell therapy product through a customised microbore tubing without compromising cell viability. Finally, the device was shown to be safe and easy to use as evidenced by usability testing. The clinical device has since been granted European market access and plans for clinical use are currently underway. The device is expected to find use in the emerging area of cell therapies and a broad spectrum of traditional parenteral drug delivery applications.
Assuntos
Terapia Baseada em Transplante de Células e Tecidos/instrumentação , Injeções Intradérmicas/instrumentação , Animais , Automação , Desenho de Equipamento , Marketing , Agulhas , Preparações Farmacêuticas , SuínosRESUMO
Intradermal immunization of mice against hepatitis B surface antigen (HBsAg) using a novel real-time controlled jet injector was assessed by comparison with intradermal and subcutaneous injection of antigen using a 27G needle and syringe. Three doses of aluminium-absorbed HBsAg were delivered at 0, 14, and 28days. Antibodies to HBsAg were detected only in mice injected with antigen with antibody levels increasing with secondary injections. Mice vaccinated by intradermal injection using the jet injector or subcutaneous needle injection exhibited comparable immune responses at day 47. Differences in titer observed between intradermal jet injected and needle injected animals reflect differences in the volume of antigen delivered. With the exception of minor bleeding at the injection site in a few animals injected either by jet injection or needle, no adverse events were observed in any of the mice used in the study.
Assuntos
Sistemas de Liberação de Medicamentos/instrumentação , Antígenos de Superfície da Hepatite B/administração & dosagem , Vacinas contra Hepatite B/administração & dosagem , Vírus da Hepatite B/imunologia , Hepatite B/prevenção & controle , Imunização/instrumentação , Animais , Sistemas de Liberação de Medicamentos/efeitos adversos , Feminino , Hepatite B/imunologia , Antígenos de Superfície da Hepatite B/imunologia , Vacinas contra Hepatite B/imunologia , Humanos , Imunização/efeitos adversos , Injeções Intradérmicas/efeitos adversos , Injeções Intradérmicas/instrumentação , Injeções a Jato/efeitos adversos , Injeções a Jato/instrumentação , Injeções Subcutâneas/efeitos adversos , Injeções Subcutâneas/instrumentação , Camundongos , Camundongos Endogâmicos BALB C , AgulhasRESUMO
Administration of 1/5th dose of Inactivated poliovirus vaccine intradermally (fIPV) provides similar immune response as full-dose intramuscular IPV, however, fIPV administration with BCG needle and syringe (BCG NS) is technically difficult. We compared immune response after one fIPV dose administered with BCG NS to administration with intradermal devices, referred to as Device A and B; and assessed feasibility of conducting a door-to-door vaccination campaign with fIPV. In Phase I, 452 children 6-12months old from Karachi were randomized to receive one fIPV dose either with BCG NS, Device A or Device B in a health facility. Immune response was defined as seroconversion or fourfold rise in polio neutralizing antibody titer 28days after fIPV among children whose baseline titer ≤362. In Phase II, fIPV was administered during one-day door-to-door campaign to assess programmatic feasibility by evaluating vaccinators' experience. For all three poliovirus (PV) serotypes, the immune response after BCG NS and Device A was similar, however it was lower with Device B (34/44 (77%), 31/45 (69%), 16/30 (53%) respectively for PV1; 53/78 (68%), 61/83 (74%), 42/80 (53%) for PV2; and; 58/76 (76%), 56/80 (70%), 43/77 (56%) for PV3; p<0.05 for all three serotypes). Vaccinators reported problems filling Device B in both Phases; no other operational challenges were reported during Phase II. Use of fIPV offers a dose-saving alternative to full-dose IPV.
Assuntos
Imunogenicidade da Vacina , Injeções Intradérmicas/instrumentação , Vacina Antipólio de Vírus Inativado/administração & dosagem , Vacina Antipólio de Vírus Inativado/imunologia , Vacinação/instrumentação , Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Relação Dose-Resposta Imunológica , Estudos de Viabilidade , Feminino , Humanos , Programas de Imunização/métodos , Programas de Imunização/estatística & dados numéricos , Imunização Secundária , Lactente , Injeções Intradérmicas/métodos , Injeções a Jato , Masculino , Agulhas , Paquistão/epidemiologia , Poliomielite/epidemiologia , Poliomielite/imunologia , Poliomielite/prevenção & controle , Poliovirus/imunologia , Soroconversão , Vacinação/métodosRESUMO
Microneedle arrays (MA) have been extensively investigated in recent decades for transdermal drug delivery due to their pain-free delivery, minimal skin trauma, and reduced risk of infection. However, porous MA received relatively less attention due to their complex fabrication process and ease of fracturing. Here, we present a titanium porous microneedle array (TPMA) fabricated by modified metal injection molding (MIM) technology. The sintering process is simple and suitable for mass production. TPMA was sintered at a sintering temperature of 1250°C for 2 h. The porosity of TPMA was approximately 30.1% and its average pore diameter was about 1.3 µm. The elements distributed on the surface of TPMA were only Ti and O, which may guarantee the biocompatibility of TPMA. TPMA could easily penetrate the skin of a human forearm without fracture. TPMA could diffuse dry Rhodamine B stored in micropores into rabbit skin. The cumulative permeated flux of calcein across TPMA with punctured skin was 27 times greater than that across intact skin. Thus, TPMA can continually and efficiently deliver a liquid drug through open micropores in skin.