Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
1.
Mol Pharm ; 18(11): 4224-4230, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34623822

RESUMO

p-Boronophenylmethoxycarbonyl (BPmoc) is a protecting group for amines that is removable by treatment with hydrogen peroxide (H2O2). We prepared BPmoc-modified insulin (BPmoc-Ins) and subcutaneously injected the formulation into diabetic rats. The results demonstrated that BPmoc effectively sealed the blood glucose (Glc)-lowering effects of Ins. Conversely, coinjection of BPmoc-Ins and Glc oxidase (GOx) resulted in reduced blood Glc levels, indicating that Ins was generated from BPmoc-Ins through the following reactions: oxidation of endogenous Glc by GOx; production of H2O2 accompanied by Glc oxidation; removal of BPmoc residues by H2O2. These results show the potential of BPmoc-Ins for a Glc-responsive Ins release system.


Assuntos
Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Peróxido de Hidrogênio/química , Insulina Regular Humana/administração & dosagem , Animais , Glicemia/análise , Glicemia/química , Ácidos Borônicos/química , Preparações de Ação Retardada/administração & dosagem , Preparações de Ação Retardada/química , Preparações de Ação Retardada/farmacocinética , Diabetes Mellitus Tipo 2/sangue , Modelos Animais de Doenças , Liberação Controlada de Fármacos , Glucose Oxidase/metabolismo , Humanos , Peróxido de Hidrogênio/metabolismo , Injeções Subcutâneas , Insulina Regular Humana/química , Insulina Regular Humana/farmacocinética , Oxirredução , Ratos
3.
Mol Metab ; 48: 101209, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33705986

RESUMO

BACKGROUND: Type 2 diabetes (T2D) is a common metabolic disease. Variants in human IGF2 mRNA binding protein 2 (IMP2/IGF2BP2) are associated with increased risk of T2D. IMP2 contributes to T2D susceptibility primarily through effects on insulin secretion. However, the underlying mechanism is not known. METHODS: To understand the role of IMP2 in insulin secretion and T2D pathophysiology, we generated Imp2 pancreatic ß-cell specific knockout mice (ßIMP2KO) by recombining the Imp2flox allele with Cre recombinase driven by the rat insulin 2 promoter. We further characterized metabolic phenotypes of ßIMP2KO mice and assessed their ß-cell functions. RESULTS: The deletion of IMP2 in pancreatic ß-cells leads to reduced compensatory ß-cell proliferation and function. Mechanically, IMP2 directly binds to Pdx1 mRNA and stimulates its translation in an m6A dependent manner. Moreover, IMP2 orchestrates IGF2-AKT-GSK3ß-PDX1 signaling to stable PDX1 polypeptides. In human EndoC-ßH1 cells, the over-expression of IMP2 is capable to enhance cell proliferation, PDX1 protein level and insulin secretion. CONCLUSION: Our work therefore reveals IMP2 as a critical regulator of pancreatic ß-cell proliferation and function; highlights the importance of posttranscriptional gene expression in T2D pathology.


Assuntos
Adenosina/análogos & derivados , Proliferação de Células/genética , Diabetes Mellitus Tipo 2/metabolismo , Proteínas de Homeodomínio/metabolismo , Secreção de Insulina/genética , Células Secretoras de Insulina/metabolismo , RNA Mensageiro/metabolismo , Proteínas de Ligação a RNA/metabolismo , Transdução de Sinais/genética , Transativadores/metabolismo , Adenosina/metabolismo , Animais , Linhagem Celular , Diabetes Mellitus Tipo 2/genética , Dieta Hiperlipídica/efeitos adversos , Modelos Animais de Doenças , Técnicas de Inativação de Genes , Humanos , Insulina Regular Humana/administração & dosagem , Insulina Regular Humana/genética , Insulina Regular Humana/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Pessoa de Meia-Idade , Regiões Promotoras Genéticas , Proteínas de Ligação a RNA/genética , Ratos , Transfecção
4.
Biol Pharm Bull ; 44(2): 251-258, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33518677

RESUMO

Multiple daily injections of insulin for diabetes cause many hazards for diabetic patients. Oral noninvasive insulin delivery could be more convenient and less painful than parenteral route. In past decades transdermal iontophoresis had been studied for insulin delivery across the skin with or without chemical permeation enhancers. However, the results of these studies were not efficacious and serum insulin levels were not therapeutically effective. In the present study an advanced technology "gut iontophoresis" for insulin delivery across the gut wall was compared with traditional oral insulin delivery in the form of nanoparticles. In vitro application of electric current to the intestinal membrane could enhance the flux of insulin nanoparticles (3.4 fold enhancement of insulin transport) from the donor to the receptor compartment in the Franz cell. In vivo iontophoresis of insulin nanoparticles through the gut wall would produce intense hypoglycemia (57% glycemia drop in 3 h) without damage of the intestinal tissues. Cell viability assay indicated that 50-500 µg/mL nanoparticles had no toxic effect on Caco-2 cells. Nanoparticles gut iontophoresis could be a promising non-invasive technique for oral insulin delivery.


Assuntos
Glicemia/efeitos dos fármacos , Hipoglicemiantes/administração & dosagem , Insulina Regular Humana/administração & dosagem , Mucosa Intestinal/metabolismo , Iontoforese/métodos , Administração Oral , Animais , Células CACO-2 , Avaliação Pré-Clínica de Medicamentos , Humanos , Hipoglicemiantes/farmacocinética , Insulina Regular Humana/farmacocinética , Masculino , Nanopartículas/administração & dosagem , Permeabilidade , Ratos
5.
Mol Pharm ; 18(4): 1593-1603, 2021 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-33617269

RESUMO

Oral delivery of insulin remains a challenge owing to its poor permeability across the small intestine and enzymatic digestion in the gastrointestinal tract. In a previous study, we identified a small intestine-permeable cyclic peptide, C-DNPGNET-C (C-C disulfide bond, cyclic DNP peptide), which facilitated the permeation of macromolecules. Here, we showed that intraintestinal and oral coadministration of insulin with the cyclic DNP derivative significantly reduced blood glucose levels by increasing the portal plasma insulin concentration following permeation across the small intestine of mice. We also found that protecting the cyclic DNP derivative from enzymatic digestion in the small intestine of mice using d-amino acids and by the cyclization of DNP peptide was essential to enhance cyclic DNP derivative-induced insulin absorption across the small intestine. Furthermore, intraintestinal and oral coadministration of insulin hexamer stabilized by zinc ions (Zn-insulin) with cyclic D-DNP derivative was more effective in facilitating insulin absorption and inducing hypoglycemic effects in mice than the coadministration of insulin with the cyclic D-DNP derivative. Moreover, Zn-insulin was more resistant to degradation in the small intestine of mice compared to insulin. Intraintestinal and oral coadministration of Zn-insulin with cyclic DNP derivative also reduced blood glucose levels in a streptozotocin-induced diabetes mellitus mouse model. A single intraintestinal administration of the cyclic D-DNP derivative did not induce any cytotoxicity, either locally in the small intestine or systemically. In summary, we demonstrated that coadministration of Zn-insulin with cyclic D-DNP derivative could enhance oral insulin absorption across the small intestine in mice.


Assuntos
Diabetes Mellitus Experimental/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Insulina Regular Humana/administração & dosagem , Peptídeos Cíclicos/administração & dosagem , Zinco/química , Administração Oral , Animais , Glicemia/análise , Glicemia/efeitos dos fármacos , Diabetes Mellitus Experimental/sangue , Diabetes Mellitus Experimental/induzido quimicamente , Humanos , Hipoglicemiantes/química , Hipoglicemiantes/farmacocinética , Insulina Regular Humana/química , Insulina Regular Humana/metabolismo , Insulina Regular Humana/farmacocinética , Absorção Intestinal , Intestino Delgado/metabolismo , Masculino , Camundongos , Peptídeos Cíclicos/farmacocinética , Permeabilidade , Proteólise , Estreptozocina/administração & dosagem , Estreptozocina/toxicidade
6.
J Mater Chem B ; 8(40): 9335-9342, 2020 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-32969458

RESUMO

Insulin administration at mealtimes for the control of postprandial glucose is a major part of basal-bolus insulin therapy; however, painful subcutaneous (SC) injections lead to poor patient compliance. The microneedle (MN) patch, which allows painless transdermal drug delivery, is a promising substitute; however, it remains a big challenge to deliver insulin as rapidly as by SC injection. Here a novel MN patch is designed in which the MNs are coated with insulin/poly-l-glutamic acid (PGA) layer-by-layer (LBL) films at pH 3.0. This coating is pH-sensitive because the net charge of insulin turns from positive to negative when the pH increases from 3.0 to 7.4. As a result, when transferred to pH 7.4 media, e.g., when inserted into skin, the coating dissociates instantly and releases insulin rapidly. A brief epidermal application (<1 min) of the coated MNs is enough for complete film dissociation. More importantly, the coated MN patch exhibits a pharmacokinetic and a pharmacodynamic profile comparable to that of insulin administrated by SC injection, suggesting the coated MN patch can deliver insulin as rapidly as the SC injection. In addition, the patch exhibits excellent biocompatibility and storage stability. The new MN patch is expected to become a painless, convenient method for the control of postprandial glucose.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Insulina Regular Humana/administração & dosagem , Microinjeções/métodos , Agulhas , Administração Cutânea , Animais , Diabetes Mellitus Experimental/tratamento farmacológico , Sistemas de Liberação de Medicamentos/instrumentação , Humanos , Insulina Regular Humana/uso terapêutico , Masculino , Microinjeções/instrumentação , Polimetil Metacrilato/química , Polimetil Metacrilato/toxicidade , Ratos Sprague-Dawley , Pele/metabolismo , Suínos
7.
Diabetes Care ; 43(11): 2713-2720, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32928957

RESUMO

OBJECTIVE: To evaluate the incidence and risk factors for diabetic ketoacidosis (DKA) and related adverse events (AEs) in adults with type 1 diabetes treated with sotagliflozin adjunctive to insulin. RESEARCH DESIGN AND METHODS: Data from two identically designed, 52-week, randomized studies were pooled and analyzed for DKA, changes in ß-hydroxybutyrate (BHB), and percentage of patients with BHB >0.6 and >1.5 mmol/L. The patients were administered placebo, sotagliflozin 200 mg, or sotagliflozin 400 mg once daily. RESULTS: A total of 191 ketosis-related AEs were reported, and 98 underwent adjudication. Of these, 37 events (36 patients) were adjudicated as DKA, with an exposure-adjusted incidence rate of 0.2, 3.1, and 4.2 events per 100 patient-years for placebo, sotagliflozin 200 mg, and sotagliflozin 400 mg, respectively. No patient died of a DKA event. From a baseline BHB of ∼0.13 mmol/L, sotagliflozin treatment led to a small median increase over 52 weeks (≤0.05 mmol/L at all time points). Of sotagliflozin-treated patients, approximately 47% and 7% had ≥1 BHB measurement >0.6 mmol/L and >1.5 mmol/L, respectively (vs. 20% and 2%, respectively, of placebo-treated patients). Subsequent to the implementation of a risk mitigation plan, annualized DKA incidence was lower versus preimplementation in both the sotagliflozin 200 and 400 mg groups. CONCLUSIONS: In patients with type 1 diabetes, confirmed DKA incidence increased when sotagliflozin was added to insulin compared with insulin alone. A lower incidence of DKA was observed following the implementation of an enhanced risk mitigation plan, suggesting that this risk can be managed with patient education.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética/induzido quimicamente , Cetoacidose Diabética/epidemiologia , Glicosídeos/efeitos adversos , Insulina Regular Humana/administração & dosagem , Transportador 1 de Glucose-Sódio/antagonistas & inibidores , Inibidores do Transportador 2 de Sódio-Glicose/efeitos adversos , Ácido 3-Hidroxibutírico/sangue , Adulto , Cetoacidose Diabética/sangue , Método Duplo-Cego , Quimioterapia Combinada/efeitos adversos , Feminino , Seguimentos , Glicosídeos/administração & dosagem , Humanos , Incidência , Masculino , Inibidores do Transportador 2 de Sódio-Glicose/administração & dosagem , Resultado do Tratamento
8.
Diabetes Care ; 43(9): 2146-2152, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32661108

RESUMO

OBJECTIVE: A major obstacle in optimizing the performance of closed-loop automated insulin delivery systems has been the delay in insulin absorption and action that results from the subcutaneous (SC) route of insulin delivery leading to exaggerated postmeal hyperglycemic excursions. We aimed to investigate the effect of Afrezza inhaled insulin with ultrafast-in and -out action profile on improving postprandial blood glucose control during hybrid closed-loop (HCL) treatment in young adults with type 1 diabetes. RESEARCH DESIGN AND METHODS: We conducted an inpatient, three-way, randomized crossover standardized meal study to assess the efficacy and safety of Afrezza at a low (AL) and a high (AH) dose as compared with a standard SC rapid-acting insulin (aspart) premeal bolus during Diabetes Assistant (DiAs) HCL treatment. Participants received two sequential meals on three study days, and premeal insulin bolus was determined based on home insulin-to-carbohydrate ratio for each meal (rounded up to the closest available Afrezza cartridge dose for AH and down for AL). The primary efficacy outcome was the peak postprandial plasma glucose (PPG) level calculated by pooling data for up to 4 h after the start of each meal. Secondary outcomes included hyperglycemic, hypoglycemic, and euglycemic venous glucose metrics. RESULTS: The mean ± SD PPG for the rapid-acting insulin control arm and AH was similar (185 ± 50 mg/dL vs. 195 ± 46 mg/dL, respectively; P = 0.45), while it was higher for meals using AL (208 ± 54 mg/dL, P = 0.04). The AH achieved significantly lower early PPG level than the control arm (30 min; P < 0.001), and improvement in PPG waned at later time points (120 and 180 min; P = 0.02) coinciding with the end of Afrezza glucodynamic action. CONCLUSIONS: Afrezza (AH) premeal bolus reduced the early glycemic excursion and improved PPG during HCL compared with aspart premeal bolus. The improvement in PPG was not sustained after the end of Afrezza glucodynamic action at 120 min.


Assuntos
Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Insulina Regular Humana/administração & dosagem , Administração por Inalação , Adolescente , Adulto , Glicemia/análise , Glicemia/metabolismo , Automonitorização da Glicemia/efeitos adversos , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Relação Dose-Resposta a Droga , Equipamentos e Provisões , Feminino , Controle Glicêmico/efeitos adversos , Controle Glicêmico/instrumentação , Controle Glicêmico/métodos , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Insulina Regular Humana/efeitos adversos , Masculino , Refeições , Período Pós-Prandial/efeitos dos fármacos , Adulto Jovem
9.
Commun Biol ; 3(1): 313, 2020 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-32555343

RESUMO

Accumulating evidence demonstrates that not only sustained elevation of blood glucose levels but also the glucose fluctuation represents key determinants for diabetic complications and mortality. Current closed-loop insulin therapy option is limited to the use of electronics-based systems, although it poses some technical issues with high cost. Here we demonstrate an electronics-free, synthetic boronate gel-based insulin-diffusion-control device technology that can cope with glucose fluctuations and potentially address the electronics-derived issues. The gel was combined with hemodialysis hollow fibers and scaled suitable for rats, serving as a subcutaneously implantable, insulin-diffusion-active site in a manner dependent on the subcutaneous glucose. Continuous glucose monitoring tests revealed that our device not only normalizes average glucose level of rats, but also markedly ameliorates the fluctuations over timescale of a day without inducing hypoglycemia. With inherent stability, diffusion-dependent scalability, and week-long & acute glucose-responsiveness, our technology may offer a low-cost alternative to current electronics-based approaches.


Assuntos
Glicemia/metabolismo , Géis/química , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Animais , Diabetes Mellitus Experimental/sangue , Diabetes Mellitus Experimental/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Liberação Controlada de Fármacos , Eletrônica , Desenho de Equipamento , Insulina/farmacocinética , Insulina Regular Humana/administração & dosagem , Insulina Regular Humana/genética , Rins Artificiais , Masculino , Modelos Teóricos , Ratos Sprague-Dawley , Temperatura
10.
Nanoscale Horiz ; 5(4): 663-670, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32226966

RESUMO

Transdermal patches have become a widely used approach for painless delivery of drugs. One major current limitation of these systems remains the restricted skin permeation of proteins and peptides as exemplified by insulin, necessitating different considerations for their successful transdermal delivery. We present a novel patch design based on the integration of nano-engineered heating elements on polyimide substrates for electrothermal transdermal therapy. The results reveal that tuning of the electrical resistivity of an array of gold nanoholes, patterned on polyimide, facilitates a fast-responding electrothermal skin patch, while post-coating with reduced graphene oxide offers capabilities for drug encapsulation, like insulin. Application of insulin-loaded patches to the skin of mice resulted in blood glucose regulation within minutes. While demonstrated for insulin, the skin patches might be well adapted to other low and high molecular weight therapeutic drugs, enabling on-demand electrothermal transdermal delivery.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Insulina Regular Humana/administração & dosagem , Adesivo Transdérmico , Dispositivos Eletrônicos Vestíveis , Administração Cutânea , Animais , Sistemas de Liberação de Medicamentos/instrumentação , Liberação Controlada de Fármacos , Ouro/química , Grafite/química , Camundongos , Nanoporos
11.
Diabetes Care ; 43(3): 607-615, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31937608

RESUMO

OBJECTIVE: Assess the efficacy of inControl AP, a mobile closed-loop control (CLC) system. RESEARCH DESIGN AND METHODS: This protocol, NCT02985866, is a 3-month parallel-group, multicenter, randomized unblinded trial designed to compare mobile CLC with sensor-augmented pump (SAP) therapy. Eligibility criteria were type 1 diabetes for at least 1 year, use of insulin pumps for at least 6 months, age ≥14 years, and baseline HbA1c <10.5% (91 mmol/mol). The study was designed to assess two coprimary outcomes: superiority of CLC over SAP in continuous glucose monitor (CGM)-measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L. RESULTS: Between November 2017 and May 2018, 127 participants were randomly assigned 1:1 to CLC (n = 65) versus SAP (n = 62); 125 participants completed the study. CGM time below 3.9 mmol/L was 5.0% at baseline and 2.4% during follow-up in the CLC group vs. 4.7% and 4.0%, respectively, in the SAP group (mean difference -1.7% [95% CI -2.4, -1.0]; P < 0.0001 for superiority). CGM time above 10 mmol/L was 40% at baseline and 34% during follow-up in the CLC group vs. 43% and 39%, respectively, in the SAP group (mean difference -3.0% [95% CI -6.1, 0.1]; P < 0.0001 for noninferiority). One severe hypoglycemic event occurred in the CLC group, which was unrelated to the study device. CONCLUSIONS: In meeting its coprimary end points, superiority of CLC over SAP in CGM-measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L, the study has demonstrated that mobile CLC is feasible and could offer certain usability advantages over embedded systems, provided the connectivity between system components is stable.


Assuntos
Técnicas Biossensoriais/instrumentação , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Telemedicina/instrumentação , Adolescente , Adulto , Idoso , Técnicas Biossensoriais/métodos , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Automonitorização da Glicemia/efeitos adversos , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Feminino , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Insulina Regular Humana/administração & dosagem , Insulina Regular Humana/efeitos adversos , Masculino , Pessoa de Meia-Idade , Aplicativos Móveis , Pâncreas Artificial , Estados Unidos , Adulto Jovem
12.
Diabetes Care ; 43(3): 597-606, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31974099

RESUMO

OBJECTIVE: The rapid insulin-alone artificial pancreas improves glycemia in type 1 diabetes but daytime control remains suboptimal. We propose two novel dual-hormone artificial pancreas systems. RESEARCH DESIGN AND METHODS: We conducted a randomized crossover trial comparing a rapid insulin-alone artificial pancreas with rapid insulin-and-pramlintide and with regular insulin-and-pramlintide artificial pancreas systems in adults with type 1 diabetes. Participants were assigned to the interventions in random order during three 24-h inpatient visits. Each visit was preceded by an outpatient hormonal open-loop run-in period of 10-14 days. The dual-hormone artificial pancreas delivered pramlintide in a basal-bolus manner, using a novel dosing algorithm, with a fixed ratio relative to insulin. The primary outcome was time in the range 3.9-10.0 mmol/L. RESULTS: Compared with the rapid insulin-alone artificial pancreas system, the rapid insulin-and-pramlintide system increased the time in range from 74% (SD 18%) to 84% (13%) (P = 0.0014), whereas the regular insulin-and-pramlintide system did not change the time in range (69% [19%]; P = 0.22). The increased time in range with the rapid insulin-and-pramlintide system was due to improved daytime control (daytime time in range increased from 63% [23%] to 78% [16%], P = 0.0004). There were 11 (1 per 2.5 days) hypoglycemic events (<3.3 mmol/L with symptoms or <3.0 mmol/L irrespective of symptoms) with the rapid insulin-alone system, compared with 12 (1 per 2.3 days) and 18 (1 per 1.4 days) with the rapid and regular insulin-and-pramlintide systems, respectively. Gastrointestinal symptoms were reported after 0% (0 of 112) of meals with the rapid insulin-alone system, compared with 6% (6 of 108) and 11% (11 of 104) with the rapid and regular insulin-and-pramlintide systems, respectively; none of the symptoms were severe. CONCLUSIONS: A novel rapid insulin-and-pramlintide artificial pancreas improves glucose control compared with a rapid insulin-alone artificial pancreas (ClinicalTrials.gov number NCT02814123).


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Polipeptídeo Amiloide das Ilhotas Pancreáticas/administração & dosagem , Pâncreas Artificial , Adolescente , Adulto , Algoritmos , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Criança , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Quimioterapia Combinada , Feminino , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Insulina Regular Humana/administração & dosagem , Insulina Regular Humana/efeitos adversos , Polipeptídeo Amiloide das Ilhotas Pancreáticas/efeitos adversos , Masculino , Refeições , Pâncreas Artificial/efeitos adversos , Adulto Jovem
13.
Diabetes Care ; 43(2): 480-483, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31796571

RESUMO

OBJECTIVE: To evaluate exercise-related glucose and counterregulatory responses (CRR) in adults with type 1 diabetes with impaired awareness of hypoglycemia (IAH) using hybrid closed-loop (HCL) insulin delivery to maintain glucose homeostasis. RESEARCH DESIGN AND METHODS: Twelve participants undertook 45-min high-intensity intermittent exercise (HIIE) and moderate-intensity exercise (MIE) in random order. The primary outcome was continuous glucose monitoring (CGM) time in range (70-180 mg/dL) for 24-h post-exercise commencement. RESULTS: CGM time in range was similar for HIIE and MIE (median 79.5% [interquartile range 73.2, 87.6] vs. 76.1% [70.3, 83.9], P = 0.37), and time with levels <54mg/dL post-exercise commencement was 0%. HIIE induced greater increases in cortisol (P = 0.002), noradrenaline (P = 0.005), and lactate (P = 0.002), with no differences in adrenaline, dopamine, growth hormone, or glucagon responses. CONCLUSIONS: IAH adults using HCL undertaking HIIE and MIE exhibit heterogeneity in CRR. Novel findings were a preserved cortisol response and variable catecholamine responses to HIIE.


Assuntos
Conscientização/fisiologia , Diabetes Mellitus Tipo 1 , Exercício Físico/fisiologia , Glucose/uso terapêutico , Hipoglicemia/psicologia , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adulto , Glicemia/análise , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Disfunção Cognitiva/sangue , Disfunção Cognitiva/etiologia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/psicologia , Retroalimentação Fisiológica/efeitos dos fármacos , Retroalimentação Fisiológica/fisiologia , Feminino , Humanos , Hipoglicemia/induzido quimicamente , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Insulina Regular Humana/administração & dosagem , Insulina Regular Humana/efeitos adversos , Ácido Láctico/sangue , Masculino , Pessoa de Meia-Idade
14.
BMJ Open Diabetes Res Care ; 7(1): e000825, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31803485

RESUMO

Objective: To evaluate multiple determinants of the longitudinal change in insulin clearance (IC) in subjects at high risk for type 2 diabetes (T2D). Research design and methods: Adults (n=492) at risk for T2D in the Prospective Metabolism and Islet Cell Evaluation cohort, a longitudinal observational cohort, had four visits over 9 years. Values from oral glucose tolerance tests collected at each assessment were used to calculate the ratios of both fasting C peptide-to-insulin (ICFASTING) and areas under the curve of C peptide-to-insulin (ICAUC). Generalized estimating equations (GEE) evaluated multiple determinants of longitudinal changes in IC. Results: IC declined by 20% over the 9-year follow-up period (p<0.05). Primary GEE results indicated that non-European ethnicity, as well as increases in baseline measures of waist circumference, white cell count, and alanine aminotransferase, was associated with declines in ICFASTING and ICAUC over time (all p<0.05). There were no significant associations of IC with sex, age, physical activity, smoking, or family history of T2D. Both baseline and longitudinal IC were associated with incident dysglycemia. Conclusions: Our findings suggest that non-European ethnicity and components of the metabolic syndrome, including central obesity, non-alcoholic fatty liver disease, and subclinical inflammation, may be related to longitudinal declines in IC.


Assuntos
Diabetes Mellitus Tipo 2/metabolismo , Hipoglicemiantes/metabolismo , Insulina Regular Humana/metabolismo , Ilhotas Pancreáticas/metabolismo , Ilhotas Pancreáticas/patologia , Estado Pré-Diabético/metabolismo , Biomarcadores/análise , Glicemia/análise , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/patologia , Feminino , Seguimentos , Teste de Tolerância a Glucose , Humanos , Hipoglicemiantes/administração & dosagem , Resistência à Insulina , Insulina Regular Humana/administração & dosagem , Ilhotas Pancreáticas/efeitos dos fármacos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estado Pré-Diabético/tratamento farmacológico , Estado Pré-Diabético/patologia , Prognóstico , Estudos Prospectivos
15.
Diabetes Obes Metab ; 21(10): 2294-2304, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31183936

RESUMO

AIMS: We previously quantified the hypoglycaemia-sparing effect of portal vs peripheral human insulin delivery. The current investigation aimed to determine whether a bioequivalent peripheral vein infusion of a hepatopreferential insulin analog, insulin-406, could similarly protect against hypoglycaemia. MATERIALS AND METHODS: Dogs received human insulin infusions into either the hepatic portal vein (PoHI, n = 7) or a peripheral vein (PeHI, n = 7) for 180 minutes at four-fold the basal secretion rate (6.6 pmol/kg/min) in a previous study. Insulin-406 (Pe406, n = 7) was peripherally infused at 6.0 pmol/kg/min, a rate determined to decrease plasma glucose by the same amount as with PoHI infusion during the first 60 minutes. Glucagon was fixed at basal concentrations, mimicking the diminished α-cell response seen in type 1 diabetes. RESULTS: Glucose dropped quickly with PeHI infusion, reaching 41 ± 3 mg/dL at 60 minutes, but more slowly with PoHI and Pe406 infusion (67 ± 2 and 72 ± 4 mg/dL, respectively; P < 0.01 vs PeHI for both). The hypoglycaemic nadir (c. 40 mg/dL) occurred at 60 minutes with PeHI infusion vs 120 minutes with PoHI and Pe406 infusion. ΔAUCepinephrine during the 180-minute insulin infusion period was two-fold higher with PeHI infusion compared with PoHI and Pe406 infusion. Glucose production (mg/kg/min) was least suppressed with PeHI infusion (Δ = 0.79 ± 0.33) and equally suppressed with PoHI and Pe406 infusion (Δ = 1.16 ± 0.21 and 1.18 ± 0.17, respectively; P = NS). Peak glucose utilization (mg/kg/min) was highest with PeHI infusion (4.94 ± 0.17) and less with PoHI and Pe406 infusion (3.58 ± 0.58 and 3.26 ± 0.08, respectively; P < 0.05 vs Pe for both). CONCLUSIONS: Peripheral infusion of hepatopreferential insulin can achieve a metabolic profile that closely mimics portal insulin delivery, which reduces the risk of hypoglycaemia compared with peripheral insulin infusion.


Assuntos
Hipoglicemiantes , Insulina Regular Humana , Insulina , Veia Porta/metabolismo , Animais , Glicemia/análise , Glicemia/metabolismo , Diabetes Mellitus Tipo 1 , Cães , Gluconeogênese , Humanos , Hipoglicemia/metabolismo , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/farmacologia , Infusões Intravenosas , Insulina/administração & dosagem , Insulina/análogos & derivados , Insulina/sangue , Insulina/farmacologia , Insulina Regular Humana/administração & dosagem , Insulina Regular Humana/farmacologia , Fígado/metabolismo , Masculino
16.
Diabetes Res Clin Pract ; 148: 93-101, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30583034

RESUMO

New concentrated insulins (exceeding 100 units/mL) and dedicated devices have recently become available, offering new treatment options for people with diabetes, for basal and prandial insulin supplementation. The concentrated insulin formulations range from 2-fold concentration (insulin lispro 200 units/mL) with rapid-acting prandial action to 5-fold concentration (human regular insulin, 500 units/mL) with basal and short-acting prandial actions. Long-acting basal insulins include degludec 200 units/mL and glargine 300 units/mL. Concentrated insulins have been developed with the goal of easing insulin therapy by reducing the volume and number of injections and in some cases making use of altered pharmacokinetic and pharmacodynamic properties. This review summarizes the unique characteristics of each concentrated insulin to help healthcare providers and people with diabetes understand how to best use them.


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Composição de Medicamentos , Hipoglicemiantes/administração & dosagem , Insulinas/administração & dosagem , Diabetes Mellitus Tipo 2/sangue , Relação Dose-Resposta a Droga , Composição de Medicamentos/métodos , Quimioterapia Combinada , Humanos , Hipoglicemiantes/classificação , Insulina Glargina/administração & dosagem , Insulina Lispro/administração & dosagem , Insulina de Ação Prolongada/administração & dosagem , Insulina Regular Humana/administração & dosagem , Insulinas/classificação
17.
Diabetes Obes Metab ; 21(1): 160-169, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30095210

RESUMO

AIMS: Current therapy fails to emulate rapid (first-phase) insulin release in relation to a meal, a key defect in types 1 and 2 diabetes. We aimed to quantify the pharmacokinetic (PK) and pharmacodynamic (PD) profile of insulin tregopil, an enterically-absorbed insulin analog that restores the normal distribution of insulin between the hepatic portal and peripheral circulations. MATERIALS AND METHODS: The PK and PD profiles of insulin tregopil were studied in overnight-fasted, catheterized, conscious canines using four approaches: (1) equimolar intraportal infusions of tregopil vs human insulin; (2) escalating doses of oral tregopil; (3) identical, consecutive enteric doses of tregopil; and (4) comparison of oral tregopil to inhaled and subcutaneous human insulin administration. RESULTS: Equimolar intraportal infusions of tregopil and human insulin resulted in very similar PK profiles and PD profiles were nearly identical. Enteric delivery of tregopil brought about rapid absorption with tmax = 20 minutes in most cases. Median tmax was 20 minutes for oral tregopil and inhaled insulin and 88 minutes for subcutaneous human insulin. The time required for arterial plasma insulin levels to return to baseline was approximately 90, 210 and 360 minutes for oral tregopil, inhaled insulin and subcutaneous insulin, respectively. CONCLUSIONS: Enterically delivered tregopil is rapidly absorbed and restores a portal-to-peripheral vascular distribution. These characteristics should improve postprandial hyperglycaemia in types 1 and 2 diabetes.


Assuntos
Glicemia/metabolismo , Insulina Regular Humana/farmacocinética , Insulina/farmacocinética , Animais , Glicemia/análise , Diabetes Mellitus , Cães , Feminino , Glucose/administração & dosagem , Glucose/metabolismo , Humanos , Insulina/administração & dosagem , Insulina/análogos & derivados , Insulina/sangue , Insulina Regular Humana/administração & dosagem , Insulina Regular Humana/sangue , Masculino
18.
Diabetes Care ; 41(11): 2346-2352, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30213882

RESUMO

OBJECTIVE: Healthy pancreatic ß-cells secrete the hormones insulin and amylin in a fixed ratio. Both hormones are lacking in type 1 diabetes, and postprandial glucose control using insulin therapy alone is difficult. This study tested the pharmacodynamic effects of the amylin analog pramlintide and insulin delivered in a fixed ratio over a 24-h period. RESEARCH DESIGN AND METHODS: Patients with type 1 diabetes were stabilized on insulin pump therapy with insulin lispro before a randomized, single-masked, two-way crossover, 24-h inpatient study in which regular human insulin was administered with pramlintide or placebo using separate infusion pumps in a fixed ratio (9 µg/unit). Meal content and timing and patient-specific insulin doses were the same with each treatment. The primary outcome measure was change in mean glucose by continuous glucose monitoring (CGM). Profiles of laboratory-measured glucose, insulin, glucagon, and triglycerides were also compared. RESULTS: Mean 24-h glucose measured by CGM was lower with pramlintide versus placebo (8.5 vs. 9.7 mmol/L, respectively; P = 0.012) due to a marked reduction of postprandial increments. Glycemic variability was reduced, and postprandial glucagon and triglycerides were also lower with pramlintide versus placebo. Gastrointestinal side effects were more frequent during use of pramlintide; no major hypoglycemic events occurred with pramlintide or placebo. CONCLUSIONS: Coadministration of fixed-ratio pramlintide and regular human insulin for 24 h improved postprandial hyperglycemia and glycemic variability in patients with type 1 diabetes. Longer studies including dose titration under daily conditions are needed to determine whether this regimen could provide long-term improvement of glycemic control.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hiperglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Insulina Regular Humana/administração & dosagem , Polipeptídeo Amiloide das Ilhotas Pancreáticas/administração & dosagem , Adolescente , Adulto , Idoso , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Automonitorização da Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/complicações , Esquema de Medicação , Combinação de Medicamentos , Feminino , Humanos , Hiperglicemia/sangue , Hipoglicemiantes/efeitos adversos , Sistemas de Infusão de Insulina , Insulina Regular Humana/efeitos adversos , Polipeptídeo Amiloide das Ilhotas Pancreáticas/efeitos adversos , Masculino , Refeições , Pessoa de Meia-Idade , Método Simples-Cego , Adulto Jovem
19.
Diabetes ; 67(6): 1173-1181, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29540491

RESUMO

We evaluated the hepatic and nonhepatic responses to glucose-responsive insulin (GRI). Eight dogs received GRI or regular human insulin (HI) in random order. A primed, continuous intravenous infusion of [3-3H]glucose began at -120 min. Basal sampling (-30 to 0 min) was followed by two study periods (150 min each), clamp period 1 (P1) and clamp period 2 (P2). At 0 min, somatostatin and GRI (36 ± 3 pmol/kg/min) or HI (1.8 pmol/kg/min) were infused intravenously; basal glucagon was replaced intraportally. Glucose was infused intravenously to clamp plasma glucose at 80 mg/dL (P1) and 240 mg/dL (P2). Whole-body insulin clearance and insulin concentrations were not different in P1 versus P2 with HI, but whole-body insulin clearance was 23% higher and arterial insulin 16% lower in P1 versus P2 with GRI. Net hepatic glucose output was similar between treatments in P1. In P2, both treatments induced net hepatic glucose uptake (HGU) (HI mean ± SEM 2.1 ± 0.5 vs. 3.3 ± 0.4 GRI mg/kg/min). Nonhepatic glucose uptake in P1 and P2, respectively, differed between treatments (2.6 ± 0.3 and 7.4 ± 0.6 mg/kg/min with HI vs. 2.0 ± 0.2 and 8.1 ± 0.8 mg/kg/min with GRI). Thus, glycemia affected GRI but not HI clearance, with resultant differential effects on HGU and nonHGU. GRI holds promise for decreasing hypoglycemia risk while enhancing glucose uptake under hyperglycemic conditions.


Assuntos
Avaliação Pré-Clínica de Medicamentos , Drogas em Investigação/efeitos adversos , Metabolismo Energético/efeitos dos fármacos , Hipoglicemiantes/efeitos adversos , Insulina Regular Humana/análogos & derivados , Fígado/efeitos dos fármacos , Absorção Fisiológica/efeitos dos fármacos , Animais , Glicemia/análise , Glicemia/metabolismo , Cães , Relação Dose-Resposta a Droga , Drogas em Investigação/administração & dosagem , Drogas em Investigação/farmacocinética , Gluconeogênese/efeitos dos fármacos , Técnica Clamp de Glucose , Glicosilação , Humanos , Hiperglicemia/metabolismo , Hiperglicemia/prevenção & controle , Hipoglicemia/induzido quimicamente , Hipoglicemia/metabolismo , Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/sangue , Hipoglicemiantes/farmacocinética , Infusões Intravenosas , Insulina Regular Humana/administração & dosagem , Insulina Regular Humana/efeitos adversos , Insulina Regular Humana/farmacocinética , Fígado/metabolismo , Masculino , Taxa de Depuração Metabólica , Distribuição Aleatória , Somatostatina/administração & dosagem , Somatostatina/efeitos adversos
20.
Diabetes Obes Metab ; 20(7): 1563-1577, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29508509

RESUMO

AIMS: To conduct a review in order to assess the safety of intranasal human insulin in clinical studies as well as the temporal stability of nasal insulin sprays. MATERIAL AND METHODS: An electronic search was performed using MEDLINE. We selected original research on intranasal human insulin without further additives in humans. The studies included could be of any design as long as they used human intranasal insulin as their study product. All outcomes and adverse side effects were extracted. RESULTS: A total of 38 studies in 1092 individuals receiving acute human intranasal insulin treatment and 18 studies in 832 individuals receiving human intranasal insulin treatment lasting between 21 days and 9.7 years were identified. No cases of symptomatic hypoglycaemia or severe adverse events (AEs) were reported. Transient local side effects in the nasal area were frequently experienced after intranasal insulin and placebo spray, while other AEs were less commonly reported. There were no reports of participants being excluded as a result of AEs. No instances of temporal stability of nasal insulin were reported in the literature. Tests on insulin that had been repacked into spray flasks showed that it had a chemical stability of up to 57 days. CONCLUSIONS: Our retrospective review of published studies on intranasal insulin did not reveal any safety concerns; however, there were insufficient data to ensure the long-term safety of this method of chronic insulin administration. Improved insulin preparations that cause less nasal irritation would be desirable for future treatment.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Insulina Regular Humana/administração & dosagem , Proteínas Recombinantes/administração & dosagem , Administração Intranasal , Aerossóis , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 2/sangue , Composição de Medicamentos , Estabilidade de Medicamentos , Humanos , Hiperglicemia/prevenção & controle , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/química , Hipoglicemiantes/uso terapêutico , Insulina Regular Humana/efeitos adversos , Insulina Regular Humana/química , Insulina Regular Humana/uso terapêutico , Estabilidade Proteica , Proteínas Recombinantes/efeitos adversos , Proteínas Recombinantes/química , Proteínas Recombinantes/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA