Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Br J Surg ; 108(9): 1082-1089, 2021 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-34027968

RESUMO

BACKGROUND: Given the susceptibility of organs to ischaemic injury, alternative preservation methods to static cold storage (SCS), such as normothermic machine perfusion (NMP) are emerging. The aim of this study was to perform a comparison between NMP and SCS in liver transplantation with particular attention to bile duct lesions. METHODS: The outcomes of 59 consecutive NMP-preserved donor livers were compared in a 1 : 1 propensity score-matched fashion to SCS control livers. Postoperative complications, patient survival, graft survival and bile duct lesions were analysed. RESULTS: While patients were matched for cold ischaemia time, the total preservation time was significantly longer in the NMP group (21 h versus 7 h, P < 0.001). Patient and graft survival rates at 1 year were 81 versus 82 per cent (P = 0.347) and 81 versus 79 per cent (P = 0.784) in the NMP and SCS groups, respectively. The postoperative complication rate was comparable (P = 0.086); 37 per cent NMP versus 34 per cent SCS patients had a Clavien-Dindo grade IIIb or above complication. There was no difference in early (30 days or less) (NMP 22 versus SCS 19 per cent, P = 0.647) and late (more than 30 days) (NMP 27 versus SCS 36 per cent, P = 0.321) biliary complications. However, NMP-preserved livers developed significantly fewer ischaemic-type bile duct lesions (NMP 3 versus SCS 14 per cent, P = 0.047). CONCLUSION: The use of NMP allowed for a significantly prolonged organ preservation with a lower rate of observed ischaemic-type bile duct lesions.


Assuntos
Ductos Biliares/cirurgia , Isquemia Fria/instrumentação , Transplante de Fígado/métodos , Preservação de Órgãos/instrumentação , Perfusão/instrumentação , Doadores de Tecidos , Isquemia Quente/métodos , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Retrospectivos
2.
Transplantation ; 104(8): 1591-1603, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32732836

RESUMO

BACKGROUND: Combined liver-kidney transplantation (CLKT) improves survival for liver transplant recipients with renal dysfunction; however, the tenuous perioperative hemodynamic and metabolic milieu in high-acuity CLKT recipients increases delayed graft function and kidney allograft failure. We sought to analyze whether delayed KT through pumping would improve kidney outcomes following CLKT. METHODS: A retrospective analysis (University of California Los Angeles [n = 145], Houston Methodist Hospital [n = 79]) was performed in all adults receiving CLKT at 2 high-volume transplant centers from February 2004 to January 2017, and recipients were analyzed for patient and allograft survival as well as renal outcomes following CLKT. RESULTS: A total of 63 patients (28.1%) underwent delayed implantation of pumped kidneys during CLKT (dCLKT) and 161 patients (71.9%) received early implantation of nonpumped kidneys during CLKT (eCLKT). Most recipients were high-acuity with median biologic model of end-stage liver disease (MELD) score of, 35 for dCLKT and 34 for eCLKT (P = ns). Pretransplant, dCLKT had longer intensive care unit stay, were more often intubated, and had greater vasopressor use. Despite this, dCLKT exhibited improved 1-, 3-, and 5-year patient and kidney survival (P = 0.02) and decreased length of stay (P = 0.001), kidney allograft failure (P = 0.012), and dialysis duration (P = 0.031). This reduced kidney allograft futility (death or continued need for hemodialysis within 3 mo posttransplant) for dCLKT (6.3%) compared with eCLKT (19.9%) (P = 0.013). CONCLUSIONS: Delayed implantation of pumped kidneys is associated with improved patient and renal allograft survival and decreased hospital length of stay despite longer kidney cold ischemia. These data should inform the ethical debate as to the futility of performing CLKT in high-acuity recipients.


Assuntos
Doença Hepática Terminal/cirurgia , Rejeição de Enxerto/epidemiologia , Transplante de Rim/efeitos adversos , Transplante de Fígado/efeitos adversos , Preservação de Órgãos/métodos , Idoso , Aloenxertos/imunologia , Aloenxertos/provisão & distribuição , Isquemia Fria/instrumentação , Isquemia Fria/métodos , Isquemia Fria/estatística & dados numéricos , Doença Hepática Terminal/complicações , Estudos de Viabilidade , Feminino , Rejeição de Enxerto/imunologia , Rejeição de Enxerto/prevenção & controle , Sobrevivência de Enxerto/imunologia , Humanos , Rim/imunologia , Transplante de Rim/ética , Transplante de Rim/métodos , Transplante de Rim/estatística & dados numéricos , Transplante de Fígado/ética , Transplante de Fígado/métodos , Transplante de Fígado/estatística & dados numéricos , Masculino , Futilidade Médica/ética , Pessoa de Meia-Idade , Preservação de Órgãos/instrumentação , Preservação de Órgãos/estatística & dados numéricos , Perfusão/instrumentação , Perfusão/métodos , Perfusão/estatística & dados numéricos , Insuficiência Renal/etiologia , Insuficiência Renal/cirurgia , Estudos Retrospectivos , Fatores de Tempo , Tempo para o Tratamento/estatística & dados numéricos , Transplante Homólogo/efeitos adversos , Transplante Homólogo/ética , Transplante Homólogo/métodos , Resultado do Tratamento
3.
Semin Liver Dis ; 40(3): 264-281, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32557478

RESUMO

Machine perfusion (MP) preservation is potentially one of the most significant improvements in the field of liver transplantation in the last 20 years, and it has been considered a promising strategy for improved preservation and ex situ evaluation of extended criteria donor (ECD) organs. However, MP preservation adds significant cost and logistical considerations to liver transplantation. MP protocols are mainly classified according to the perfusion temperature with hypothermic machine perfusion (HMP) and normothermic machine perfusion (NMP) being the two categories most studied so far. After extensive preclinical work, MP entered the clinical setting, and there are now several studies that demonstrated feasibility and safety. However, because of the limited quality of clinical trials, there is no compelling evidence of superiority in preservation quality, and liver MP is still considered experimental in most countries. MP preservation is moving to a more mature phase, where ongoing and future studies will bring new evidence in order to confirm their superiority in terms of clinical outcomes, organ utilization, and cost-effectiveness. Here, we present an overview of all preclinical MP studies using discarded human livers and liver MP clinical trials, and discuss their results. We describe the different perfusion protocols, pitfalls in MP study design, and provide future perspectives. Recent trials in liver MP have revealed unique challenges beyond those seen in most clinical studies. Randomized trials, correct trial design, and interpretation of data are essential to generate the data necessary to prove if MP will be the new gold standard method of liver preservation.


Assuntos
Transplante de Fígado/métodos , Preservação de Órgãos/métodos , Perfusão/métodos , Animais , Ensaios Clínicos como Assunto , Isquemia Fria/instrumentação , Humanos , Isquemia Quente/instrumentação
4.
Exp Biol Med (Maywood) ; 244(8): 630-645, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30889963

RESUMO

IMPACT STATEMENT: Over the past several decades, ex vivo perfusion has emerged as a promising technology for the assessment, preservation, and recovery of donor organs. Many exciting pre-clinical findings have now been translated to clinical use, and successful transplantation following ex vivo perfusion has been achieved for heart, lung, and liver. While machine perfusion provides distinct advantages over traditional cold preservation, many challenges remain, including that of long-term (multi-day) ex vivo support. Here, we provide an overview of the current status of ex vivo machine perfusion in the pre-clinical and clinical setting and share our perspective on the future direction of the field.


Assuntos
Bioengenharia , Preservação de Órgãos/métodos , Perfusão/métodos , Cadáver , Isquemia Fria/efeitos adversos , Isquemia Fria/instrumentação , Isquemia Fria/métodos , Previsões , Coração/fisiologia , Transplante de Coração , Humanos , Fígado/fisiologia , Transplante de Fígado , Pulmão/fisiologia , Transplante de Pulmão , Preservação de Órgãos/instrumentação , Perfusão/instrumentação , Traumatismo por Reperfusão/metabolismo , Traumatismo por Reperfusão/prevenção & controle , Coleta de Tecidos e Órgãos/métodos , Transplantes/fisiologia , Isquemia Quente/efeitos adversos
5.
Transplantation ; 103(10): 2130-2135, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30801511

RESUMO

BACKGROUND: Machine perfusion of donor livers is typically performed via the portal vein main stem. Instead, cannulation of a reopened umbilical vein could allow machine perfusion during organ procurement and subsequent implantation in the recipient without interruption of the portal venous circulation. We aimed to assess the feasibility of portal venous machine perfusion via the umbilical vein. METHODS: During back table inspection of 5 human livers declined for transplantation, the umbilical vein was surgically reopened, dilated, and cannulated. Hypothermic and normothermic oxygenated machine perfusion (NMP) were performed using the umbilical vein for portal inflow. Three livers were perfused with hypothermic machine perfusion, 1 full liver graft underwent NMP for 4 hours, and 1 left lateral split procedure was performed under continuous NMP with portal perfusion via the umbilical vein. RESULTS: In all livers, access to the portal venous system via the umbilical vein was successfully achieved with good portal flows and macroscopically homogeneous perfusion. The full liver graft that underwent NMP via the umbilical vein for 4 hours showed good lactate clearance, normalized pH, and achieved good bile production with pH >7.55. During the split procedure under continuous NMP via the umbilical vein, the left lateral segment and extended right lobe remained equally perfused, as demonstrated by Doppler ultrasound. CONCLUSIONS: Machine perfusion with portal perfusion via the umbilical vein is feasible. Portal venous flows were similar to those obtained after cannulation of the portal vein main stem. This technique enables continuous oxygenated perfusion of liver grafts during procurement, splitting, and implantation.


Assuntos
Transplante de Fígado , Preservação de Órgãos/métodos , Perfusão/métodos , Traumatismo por Reperfusão/prevenção & controle , Veias Umbilicais/cirurgia , Aloenxertos/irrigação sanguínea , Aloenxertos/patologia , Cânula , Cateterismo/instrumentação , Isquemia Fria/instrumentação , Isquemia Fria/métodos , Estudos de Viabilidade , Humanos , Fígado/irrigação sanguínea , Fígado/patologia , Preservação de Órgãos/instrumentação , Perfusão/instrumentação , Estudo de Prova de Conceito , Traumatismo por Reperfusão/etiologia , Traumatismo por Reperfusão/patologia , Obtenção de Tecidos e Órgãos/métodos
6.
Liver Transpl ; 24(12): 1699-1715, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30058119

RESUMO

Hypothermic oxygenated perfusion (HOPE) and normothermic perfusion are seen as distinct techniques of ex situ machine perfusion of the liver. We aimed to demonstrate the feasibility of combining both techniques and whether it would improve functional parameters of donor livers into transplant standards. Ten discarded human donor livers had either 6 hours of normothermic perfusion (n = 5) or 2 hours of HOPE followed by 4 hours of normothermic perfusion (n = 5). Liver function was assessed according to our viability criteria; markers of tissue injury and hepatic metabolic activity were compared between groups. Donor characteristics were comparable. During the hypothermic perfusion phase, livers down-regulated mitochondrial respiration (oxygen uptake, P = 0.04; partial pressure of carbon dioxide perfusate, P = 0.04) and increased adenosine triphosphate levels 1.8-fold. Following normothermic perfusion, those organs achieved lower tissue expression of markers of oxidative injury (4-hydroxynonenal, P = 0.008; CD14 expression, P = 0.008) and inflammation (CD11b, P = 0.02; vascular cell adhesion molecule 1, P = 0.05) compared with livers that had normothermic perfusion alone. All livers in the combined group achieved viability criteria, whereas 40% (2/5) in the normothermic group failed (P = 0.22). In conclusion, this study suggests that a combined protocol of hypothermic oxygenated and normothermic perfusions might attenuate oxidative stress, tissue inflammation, and improve metabolic recovery of the highest-risk donor livers compared with normothermic perfusion alone.


Assuntos
Seleção do Doador/normas , Transplante de Fígado/métodos , Preservação de Órgãos/métodos , Perfusão/métodos , Aloenxertos/metabolismo , Aloenxertos/cirurgia , Biomarcadores/análise , Biomarcadores/metabolismo , Isquemia Fria/instrumentação , Isquemia Fria/métodos , Estudos de Viabilidade , Humanos , Fígado/metabolismo , Fígado/cirurgia , Testes de Função Hepática , Transplante de Fígado/normas , Preservação de Órgãos/instrumentação , Estresse Oxidativo , Perfusão/instrumentação , Isquemia Quente/instrumentação , Isquemia Quente/métodos
7.
Transplantation ; 99(4): 754-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25222017

RESUMO

BACKGROUND: The metabolic processes occurring within the preserved kidney during hypothermic machine perfusion (HMP) are not well characterized. The aim of this study was to use nuclear magnetic resonance (NMR) spectroscopy to examine the metabolomic profile of HMP perfusate from human cadaveric kidneys awaiting transplantation and to identify possible discriminators between the profiles of kidneys with delayed graft function (DGF) and immediate graft function (IGF). METHODS: Perfusates from HMP kidneys were sampled at 45 min and 4 hr of preservation with the LifePort Kidney Transporter 1.0 (Organ Recovery Systems, Chicago, IL) using KPS-1. Prepared samples underwent 1-D Proton-NMR spectroscopy, and resultant spectra were analyzed. Clinical parameters were collected prospectively. RESULTS: Perfusate of 26 transplanted cadaveric kidneys was analyzed; 19(73%) with IGF and 7(27%) with DGF. Glucose concentrations were significantly lower in DGF kidneys compared to those with IGF at both 45 min (7.772 vs. 9.459 mM, P = 0.006) and 4 hr (8.202 vs. 10.235 mM, P = 0.003). Concentrations of inosine and leucine were significantly different between DGF and IGF kidneys at 45 min (0.002 vs. 0.013 mM, P = 0.009 and 0.011 vs. 0.006 mM, P = 0.036), and gluconate levels were also significantly different between DGF and IGF kidneys at 4 hr (49.099 vs. 59.513 mM, P = 0.009). CONCLUSION: Significant metabolic activity may be occurring in kidneys during HMP. The NMR spectroscopy of the perfusate can identify differences in the metabolomic profiles of DGF and IGF kidneys that might have a predictive role in viability assessment. Modification of harmful metabolic processes may improve outcomes for HMP kidneys.


Assuntos
Isquemia Fria , Hipotermia Induzida , Transplante de Rim/métodos , Rim/irrigação sanguínea , Rim/metabolismo , Metabolômica , Soluções para Preservação de Órgãos/metabolismo , Preservação de Órgãos/métodos , Perfusão/métodos , Doadores de Tecidos , Área Sob a Curva , Cadáver , Isquemia Fria/efeitos adversos , Isquemia Fria/instrumentação , Função Retardada do Enxerto/etiologia , Função Retardada do Enxerto/metabolismo , Desenho de Equipamento , Humanos , Hipotermia Induzida/efeitos adversos , Hipotermia Induzida/instrumentação , Rim/cirurgia , Transplante de Rim/efeitos adversos , Espectroscopia de Ressonância Magnética , Metabolômica/métodos , Preservação de Órgãos/efeitos adversos , Preservação de Órgãos/instrumentação , Perfusão/efeitos adversos , Perfusão/instrumentação , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Wien Klin Wochenschr ; 126(11-12): 329-34, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24652018

RESUMO

PURPOSE: In the present study, we aimed to determine whether the use of self-retaining barbed sutures (SRBS) instead of conventional sutures during open partial nephrectomy leads to improved surgical outcomes. PATIENTS, MATERIALS AND METHODS: A retrospective analysis of 50 consecutive patients who underwent open partial nephrectomy for a unicentric renal tumor was performed. In 15 patients, SRBS were used for parenchymal repair during open partial nephrectomy, and in 35 patients, conventional sutures were used. The parameters related to surgical outcomes were recorded and analysis of the total patient population and subgroup analysis according to the preoperative aspects and dimensions used for an anatomical (PADUA) score classification was performed. RESULTS: The preoperative baseline values did not statistically differ between the groups. Analysis of the total patient population showed a significant difference regarding ischemia time (mean ± standard deviation) between the SRBS group (15.2 ± 6.9 min), and the conventional suture group (25.7 ± 11.8 min). There was no significant difference between the barbed and conventional sutures with regard to postoperative hemoglobin levels, decline in hemoglobin percentage, or renal function parameters. In subgroup-analysis, a significant difference in ischemia time was only found for PADUA scores 6 and 7, without any effect on the outcome parameters. CONCLUSIONS: The use of SRBS in parenchymal repair during open partial nephrectomy appears to be a safe and feasible option with decreased cold ischemia time when compared with conventional sutures. In PADUA subgroup-analysis this difference was only observed for PADUA scores 6 and 7.


Assuntos
Isquemia Fria/instrumentação , Neoplasias Renais/cirurgia , Nefrectomia/instrumentação , Tratamentos com Preservação do Órgão/instrumentação , Tratamentos com Preservação do Órgão/métodos , Técnicas de Sutura/instrumentação , Suturas , Adulto , Idoso , Idoso de 80 Anos ou mais , Isquemia Fria/métodos , Feminino , Humanos , Neoplasias Renais/diagnóstico , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Retrospectivos , Resultado do Tratamento
9.
Transplantation ; 89(7): 830-7, 2010 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-20098357

RESUMO

INTRODUCTION: There is increasing support for the use of hypothermic machine perfusion (HMP) in an attempt to reduce preservation injury. However, experimental evidence is needed to further examine the effects of HMP on renal ischemia reperfusion injury. METHODS: Porcine kidneys were subjected to 10 min of warm ischemia followed by 18 hr of static cold storage with hyperosomolar citrate (HOC), histidine-tryptophan-ketoglutarate (HTK), or University of Wisconsin (UW) solutions or 18 hr HMP with Kidney Perfusion Solution using the Lifeport perfusion system. Renal function, oxidative damage, and morphology were assessed during 3 hr of reperfusion with autologous blood using an isolated organ perfusion system. RESULTS: During reperfusion, intrarenal resistance was significantly lower in the HMP group compared with HOC and UW (area under the curve; HMP 3.8+/-1.7, HOC 9.1+/-4.3, UW 7.7+/-2.2, HTK 5.6+/-1.9 mm Hg/min; P=0.006), and creatinine clearance was significantly higher compared with the UW group (area under the curve creatinine clearance; HMP 9.8+/-7.3, HOC 2.2+/-1.7, UW 1.8+/-1.0, HTK 2.1+/-1.8 mL/min/100 g; P=0.004). Tubular function was significantly improved in the HMP group (P<0.05); however, levels of lipid peroxidation were significantly higher (P=0.005). CONCLUSION: HMP demonstrated a reduced level of preservation injury compared with the static techniques resulting in improved renal and tubular function and less tubular cell inflammation during reperfusion.


Assuntos
Isquemia Fria/instrumentação , Hipotermia Induzida/instrumentação , Transplante de Rim , Rim/efeitos dos fármacos , Soluções para Preservação de Órgãos/farmacologia , Perfusão/instrumentação , Traumatismo por Reperfusão/prevenção & controle , Equilíbrio Ácido-Base/efeitos dos fármacos , Adenosina/farmacologia , Alopurinol/farmacologia , Animais , Aspartato Aminotransferases/sangue , Biomarcadores/sangue , Citratos/farmacologia , Isquemia Fria/efeitos adversos , Creatinina/sangue , Modelos Animais de Doenças , Desenho de Equipamento , Glucose/farmacologia , Glutationa/farmacologia , Hipotermia Induzida/efeitos adversos , Insulina/farmacologia , Rim/irrigação sanguínea , Rim/metabolismo , Rim/patologia , Rim/fisiopatologia , Rim/cirurgia , Transplante de Rim/efeitos adversos , L-Lactato Desidrogenase/sangue , Peroxidação de Lipídeos/efeitos dos fármacos , Manitol/farmacologia , Estresse Oxidativo/efeitos dos fármacos , Perfusão/efeitos adversos , Peroxidase/metabolismo , Cloreto de Potássio/farmacologia , Procaína/farmacologia , Rafinose/farmacologia , Traumatismo por Reperfusão/etiologia , Traumatismo por Reperfusão/metabolismo , Traumatismo por Reperfusão/patologia , Traumatismo por Reperfusão/fisiopatologia , Suínos , Fatores de Tempo
10.
Int J Artif Organs ; 32(10): 728-38, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19943234

RESUMO

BACKGROUND: Recently, a novel innovative machine perfusion (MP) system for hypothermic oxygenated pulsatile perfusion called the Airdrive (AD) has been developed. The aim of the study was to evaluate the biological safety of the AD system for perfusion preservation of kidney grafts in a porcine autotransplantation model using the low-viscosity perfusion solution Polysol (PS) in comparison with cold storage (CS) using PS or the University of Wisconsin solution (UW). In addition, we evaluated real-time microcirculation parameters. At sacrifice, grafts were retrieved for histological analysis and immunohistochemistry. METHODS: After assessment of the microcirculation, left kidneys were retrieved. Following the washout, kidneys were preserved for 20 hr using AD-PS, CS-PS or CS-UW. Thereafter, contralateral kidneys were removed followed by heterotopic autotransplantation of the preserved graft. Seven days after transplantation animals were sacrificed with retrieval of the grafts for histological analysis. Renal function, renal microcirculation and tissue injury including the proliferative response of tubular epithelial cells (TECs) were compared. RESULTS: Preservation using AD-PS or CS-PS resulted in higher microcirculatory flow compared with CS-UW. Improved recovery of renal function was seen in the AD-PS and CS-PS groups compared with CS-UW. Structural integrity was better preserved using AD-PS compared with both CS groups. Proliferative response of TECs was higher in CS-UW preserved grafts compared to grafts preserved using AD-PS. CONCLUSION: This study demonstrates the biological safety of the AD system in a porcine autotransplantation model. Also, the microcirculation was better preserved and less morphological injury was observed after 20 hr MP compared with CS.


Assuntos
Isquemia Fria , Transplante de Rim/métodos , Rim/cirurgia , Oxigênio/metabolismo , Perfusão , Fluxo Pulsátil , Coleta de Tecidos e Órgãos , Adenosina/farmacologia , Alopurinol/farmacologia , Animais , Proliferação de Células , Isquemia Fria/efeitos adversos , Isquemia Fria/instrumentação , Desenho de Equipamento , Feminino , Glutationa/farmacologia , Imuno-Histoquímica , Insulina/farmacologia , Rim/irrigação sanguínea , Rim/efeitos dos fármacos , Rim/metabolismo , Rim/patologia , Testes de Função Renal , Transplante de Rim/efeitos adversos , Transplante de Rim/instrumentação , Fluxometria por Laser-Doppler , Microcirculação , Modelos Animais , Soluções para Preservação de Órgãos/farmacologia , Perfusão/efeitos adversos , Perfusão/instrumentação , Rafinose/farmacologia , Recuperação de Função Fisiológica , Circulação Renal , Suínos , Fatores de Tempo , Coleta de Tecidos e Órgãos/efeitos adversos , Coleta de Tecidos e Órgãos/instrumentação , Transplante Autólogo
11.
Cad Saude Publica ; 23(1): 187-95, 2007 Jan.
Artigo em Português | MEDLINE | ID: mdl-17187117

RESUMO

Risk factors for failure of liver transplantation from cadaveric donors were investigated in this retrospective study using data from medical records of patients in Rio Grande do Sul, Brazil, who were submitted to liver transplantation for the first time from January 1999 to July 2003 and were over 15 years of age at the time of surgery. Some 13% of failures occurred in the first month, 11% from 2 to 12 months, and 5% after 12 months; 88% of failures resulted in death and 12% in retransplantation. In the multivariate models, rate ratios for failure were higher for total family income less than 10 times the minimum wage, recipient's age > 45 years, non-whites, high clinical risk, and donor's age > or = 56 years. Female gender showed an effect in the unadjusted model only. Special attention to patients at increased risk, with income support for those with low family income, and early diagnosis of the need for transplantation may improve the success of liver transplantation.


Assuntos
Rejeição de Enxerto/epidemiologia , Transplante de Fígado , Adolescente , Adulto , Fatores Etários , Brasil/epidemiologia , Cadáver , Isquemia Fria/instrumentação , Isquemia Fria/mortalidade , Métodos Epidemiológicos , Feminino , Rejeição de Enxerto/etiologia , Rejeição de Enxerto/mortalidade , Humanos , Hepatopatias/classificação , Hepatopatias/cirurgia , Falência Hepática/cirurgia , Transplante de Fígado/mortalidade , Masculino , Pessoa de Meia-Idade , Fatores Sexuais , Fatores Socioeconômicos , Doadores de Tecidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA