Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.399
Filtrar
1.
Environ Health Perspect ; 132(5): 56001, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38728217

RESUMO

BACKGROUND: Respiratory tract infections are major contributors to the global disease burden. Quantitative microbial risk assessment (QMRA) holds potential as a rapidly deployable framework to understand respiratory pathogen transmission and inform policy on infection control. OBJECTIVES: The goal of this paper was to evaluate, motivate, and inform further development of the use of QMRA as a rapid tool to understand the transmission of respiratory pathogens and improve the evidence base for infection control policies. METHODS: We conducted a literature review to identify peer-reviewed studies of complete QMRA frameworks on aerosol inhalation or contact transmission of respiratory pathogens. From each of the identified studies, we extracted and summarized information on the applied exposure model approaches, dose-response models, and parameter values, including risk characterization. Finally, we reviewed linkages between model outcomes and policy. RESULTS: We identified 93 studies conducted in 16 different countries with complete QMRA frameworks for diverse respiratory pathogens, including SARS-CoV-2, Legionella spp., Staphylococcus aureus, influenza, and Bacillus anthracis. Six distinct exposure models were identified across diverse and complex transmission pathways. In 57 studies, exposure model frameworks were informed by their ability to model the efficacy of potential interventions. Among interventions, masking, ventilation, social distancing, and other environmental source controls were commonly assessed. Pathogen concentration, aerosol concentration, and partitioning coefficient were influential exposure parameters as identified by sensitivity analysis. Most (84%, n=78) studies presented policy-relevant content including a) determining disease burden to call for policy intervention, b) determining risk-based threshold values for regulations, c) informing intervention and control strategies, and d) making recommendations and suggestions for QMRA application in policy. CONCLUSIONS: We identified needs to further the development of QMRA frameworks for respiratory pathogens that prioritize appropriate aerosol exposure modeling approaches, consider trade-offs between model validity and complexity, and incorporate research that strengthens confidence in QMRA results. https://doi.org/10.1289/EHP12695.


Assuntos
Infecções Respiratórias , Medição de Risco/métodos , Infecções Respiratórias/epidemiologia , Infecções Respiratórias/microbiologia , Humanos , SARS-CoV-2 , COVID-19/transmissão , COVID-19/prevenção & controle , Staphylococcus aureus , Controle de Infecções/métodos , Legionella , Aerossóis
2.
J Assoc Physicians India ; 72(3): 94-96, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38736126

RESUMO

BACKGROUND: Legionella has a higher prevalence in India than in the world. Legionaries' disease most commonly involves the lungs but because of increased awareness, extrapulmonary manifestations are also being diagnosed more frequently. CASE DESCRIPTION: We present a case of a young female with acute onset of fever and chest pain. On initial investigation, an electrocardiogram (ECG) reported widespread pulse rate (PR) depression suggestive of pericarditis which was confirmed by ECG. High-resolution computed tomography (HRCT) thorax suggested mild bilateral pleural effusion with normal lung parenchyma. elevated erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) added to the diagnosis of serositis. Serological study for atypical organisms was remarkable for positive immunoglobulin M (IgM) for Legionella. She was treated with a high dose of steroids and azithromycin successfully. CONCLUSION: Isolated extrapulmonary presentation of legionaries disease is often overlooked and is common. So it should be always included in the diagnostic armamentarium as treatment is highly efficacious if started early.


Assuntos
Azitromicina , Serosite , Humanos , Feminino , Serosite/diagnóstico , Serosite/etiologia , Azitromicina/uso terapêutico , Adulto , Antibacterianos/uso terapêutico , Legionelose/diagnóstico , Legionelose/tratamento farmacológico , Legionella/isolamento & purificação , Eletrocardiografia , Tomografia Computadorizada por Raios X , Doença dos Legionários/diagnóstico , Doença dos Legionários/tratamento farmacológico
3.
Curr Microbiol ; 81(6): 141, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38625380

RESUMO

Legionella pneumophila can be transmitted to people, especially immunocompromised patients, via hospital water pipe systems and cause severe pneumonia. The aim of our study was to investigate the presence of major virulence factor genes, ability of biofilms formation, and correlation between presence of Legionella isolates and temperature, pH, and residual chlorine of water. Hundred water samples were collected from nine hospitals in Tehran, Iran. Temperature, pH, and residual chlorine were determined during sampling. Different virulence genes and the ability to form biofilms were subsequently analyzed among the L. pneumophila isolates. Results showed that 12 (12%) samples were positive in culture method and all of the isolates were positive as L. pneumophila species (mip). A correlation was found between Legionella culture positivity and temperature and pH of water, but there was no significant correlation between residual chlorine of water samples and the presence of Legionella. The isolation of Legionella rate in summer and spring was higher than winter and autumn. Twelve (100%) isolates were positive for mip genes, 9 (75%) for dot genes, 8 (66.66%) for hsp, 6 (50%) for lvh, and 4 (33.33%) for rtx. All of the isolates displayed strong ability for biofilm production every three days. Two of these isolates (16.6%) displayed weak ability to form biofilm on the first day of incubation. This study revealed that water sources in hospitals were colonized by virulent Legionella and should be continuously monitored to avoid elevated concentrations of Legionella with visible biofilm formation.


Assuntos
Legionella pneumophila , Legionella , Humanos , Legionella pneumophila/genética , Virulência/genética , Cloro/farmacologia , Irã (Geográfico) , Biofilmes , Hospitais
4.
Environ Sci Technol ; 58(15): 6540-6551, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38574283

RESUMO

Water age in drinking water systems is often used as a proxy for water quality but is rarely used as a direct input in assessing microbial risk. This study directly linked water ages in a premise plumbing system to concentrations of Legionella pneumophila via a growth model. In turn, the L. pneumophila concentrations were used for a quantitative microbial risk assessment to calculate the associated probabilities of infection (Pinf) and clinically severe illness (Pcsi) due to showering. Risk reductions achieved by purging devices, which reduce water age, were also quantified. The median annual Pinf exceeded the commonly used 1 in 10,000 (10-4) risk benchmark in all scenarios, but the median annual Pcsi was always 1-3 orders of magnitude below 10-4. The median annual Pcsi was lower in homes with two occupants (4.7 × 10-7) than with one occupant (7.5 × 10-7) due to more frequent use of water fixtures, which reduced water ages. The median annual Pcsi for homes with one occupant was reduced by 39-43% with scheduled purging 1-2 times per day. Smart purging devices, which purge only after a certain period of nonuse, maintained these lower annual Pcsi values while reducing additional water consumption by 45-62%.


Assuntos
Água Potável , Legionella pneumophila , Legionella , Abastecimento de Água , Microbiologia da Água , Engenharia Sanitária , Medição de Risco
5.
Molecules ; 29(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38611802

RESUMO

LL-37 is the only member of the cathelicidin-type host defense peptide family in humans. It exhibits broad-spectrum bactericidal activity, which represents a distinctive advantage for future therapeutic targets. The presence of choline in the growth medium for bacteria changes the composition and physicochemical properties of their membranes, which affects LL-37's activity as an antimicrobial agent. In this study, the effect of the LL-37 peptide on the phospholipid monolayers at the liquid-air interface imitating the membranes of Legionella gormanii bacteria was determined. The Langmuir monolayer technique was employed to prepare model membranes composed of individual classes of phospholipids-phosphatidylcholine (PC), phosphatidylethanolamine (PE), phosphatidylglycerol (PG), cardiolipin (CL)-isolated from L. gormanii bacteria supplemented or non-supplemented with exogenous choline. Compression isotherms were obtained for the monolayers with or without the addition of the peptide to the subphase. Then, penetration tests were carried out for the phospholipid monolayers compressed to a surface pressure of 30 mN/m, followed by the insertion of the peptide into the subphase. Changes in the mean molecular area were observed over time. Our findings demonstrate the diversified effect of LL-37 on the phospholipid monolayers, depending on the bacteria growth conditions. The substantial changes in membrane properties due to its interactions with LL-37 enable us to propose a feasible mechanism of peptide action at a molecular level. This can be associated with the stable incorporation of the peptide inside the monolayer or with the disruption of the membrane leading to the removal (desorption) of molecules into the subphase. Understanding the role of antimicrobial peptides is crucial for the design and development of new strategies and routes for combating resistance to conventional antibiotics.


Assuntos
Anti-Infecciosos , Legionella , Legionellaceae , Humanos , Fosfolipídeos , Peptídeos Catiônicos Antimicrobianos/farmacologia , Colina
6.
Water Res ; 256: 121579, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38631237

RESUMO

Intensified land use can disturb water quality, potentially increasing the abundance of bacterial pathogens, threatening public access to clean water. This threat involves both direct contamination of faecal bacteria as well as indirect factors, such as disturbed water chemistry and microbiota, which can lead to contamination. While direct contamination has been well described, the impact of indirect factors is less explored, despite the potential of severe downstream consequences on water supply. To assess direct and indirect downstream effects of buildings, farms, pastures and fields on potential water sources, we studied five Swedish lakes and their inflows. We analysed a total of 160 samples in a gradient of anthropogenic activity spanning four time points, including faecal and water-quality indicators. Through species distribution modelling, Random Forest and network analysis using 16S rRNA amplicon sequencing data, our findings highlight that land use indirectly impacts lakes via inflows. Land use impacted approximately one third of inflow microbiota taxa, in turn impacting ∼20-50 % of lake taxa. Indirect effects via inflows were also suggested by causal links between e.g. water colour and lake bacterial taxa, where this influenced the abundance of several freshwater bacteria, such as Polynucleobacter and Limnohabitans. However, it was not possible to identify direct effects on the lakes based on analysis of physiochemical- or microbial parameters. To avoid potential downstream consequences on water supply, it is thus important to consider possible indirect effects from upstream land use and inflows, even when no direct effects can be observed on lakes. Legionella (a genus containing bacterial pathogens) illustrated potential consequences, since the genus was particularly abundant in inflows and was shown to increase by the presence of pastures, fields, and farms. The approach presented here could be used to assess the suitability of lakes as alternative raw water sources or help to mitigate contaminations in important water catchments. Continued broad investigations of stressors on the microbial network can identify indirect effects, avoid enrichment of pathogens, and help secure water accessibility.


Assuntos
Substâncias Húmicas , Ferro , Lagos , Legionella , Lagos/microbiologia , RNA Ribossômico 16S/genética , Microbiologia da Água , Suécia , Qualidade da Água , Monitoramento Ambiental
7.
Nat Commun ; 15(1): 2452, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38503748

RESUMO

ADP-ribosylation is a reversible post-translational modification involved in various cellular activities. Removal of ADP-ribosylation requires (ADP-ribosyl)hydrolases, with macrodomain enzymes being a major family in this category. The pathogen Legionella pneumophila mediates atypical ubiquitination of host targets using the SidE effector family in a process that involves ubiquitin ADP-ribosylation on arginine 42 as an obligatory step. Here, we show that the Legionella macrodomain effector MavL regulates this pathway by reversing the arginine ADP-ribosylation, likely to minimize potential detrimental effects caused by the modified ubiquitin. We determine the crystal structure of ADP-ribose-bound MavL, providing structural insights into recognition of the ADP-ribosyl group and catalytic mechanism of its removal. Further analyses reveal DUF4804 as a class of MavL-like macrodomain enzymes whose representative members show unique selectivity for mono-ADP-ribosylated arginine residue in synthetic substrates. We find such enzymes are also present in eukaryotes, as exemplified by two previously uncharacterized (ADP-ribosyl)hydrolases in Drosophila melanogaster. Crystal structures of several proteins in this class provide insights into arginine specificity and a shared mode of ADP-ribose interaction distinct from previously characterized macrodomains. Collectively, our study reveals a new regulatory layer of SidE-catalyzed ubiquitination and expands the current understanding of macrodomain enzymes.


Assuntos
Legionella , Ubiquitina , Animais , Ubiquitina/metabolismo , Legionella/metabolismo , Drosophila melanogaster/metabolismo , ADP-Ribosilação , Adenosina Difosfato Ribose/metabolismo , Hidrolases/metabolismo
8.
Virulence ; 15(1): 2327096, 2024 12.
Artigo em Inglês | MEDLINE | ID: mdl-38466143

RESUMO

Legionella pneumophila (L. pneumophila) is a prevalent pathogenic bacterium responsible for significant global health concerns. Nonetheless, the precise pathogenic mechanisms of L. pneumophila have still remained elusive. Autophagy, a direct cellular response to L. pneumophila infection and other pathogens, involves the recognition and degradation of these invaders in lysosomes. Histone deacetylase 6 (HDAC6), a distinctive member of the histone deacetylase family, plays a multifaceted role in autophagy regulation. This study aimed to investigate the role of HDAC6 in macrophage autophagy via the autophagolysosomal pathway, leading to alleviate L. pneumophila-induced pneumonia. The results revealed a substantial upregulation of HDAC6 expression level in murine lung tissues infected by L. pneumophila. Notably, mice lacking HDAC6 exhibited a protective response against L. pneumophila-induced pulmonary tissue inflammation, which was characterized by the reduced bacterial load and diminished release of pro-inflammatory cytokines. Transcriptomic analysis has shed light on the regulatory role of HDAC6 in L. pneumophila infection in mice, particularly through the autophagy pathway of macrophages. Validation using L. pneumophila-induced macrophages from mice with HDAC6 gene knockout demonstrated a decrease in cellular bacterial load, activation of the autophagolysosomal pathway, and enhancement of cellular autophagic flux. In summary, the findings indicated that HDAC6 knockout could lead to the upregulation of p-ULK1 expression level, promoting the autophagy-lysosomal pathway, increasing autophagic flux, and ultimately strengthening the bactericidal capacity of macrophages. This contributes to the alleviation of L. pneumophila-induced pneumonia.


Assuntos
Legionella pneumophila , Legionella , Doença dos Legionários , Pneumonia , Animais , Camundongos , Autofagia , Desacetilase 6 de Histona/genética , Legionella pneumophila/genética , Doença dos Legionários/genética , Macrófagos
9.
J Clin Microbiol ; 62(4): e0166523, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38501659

RESUMO

Many Legionella pneumonia patients do not produce sputum, and it is unknown whether purulent sputum is required for the identification of Legionella species. This study aimed to evaluate the identification rate of Legionella species based on sputum quality and the factors predictive of Legionella infection. This study included Legionella pneumonia patients at Kurashiki Central Hospital from November 2000 to December 2022. Sputum quality, based on gram staining, was classified as the following: Geckler 1/2, 3/6 and 4/5. Geckler 4/5 was defined as purulent sputum. The sputa of 104 of 124 Legionella pneumonia patients were cultured. Fifty-four patients (51.9%) were identified with Legionella species, most of which were Legionella pneumophila serogroup 1 (81.5%). The identification rates of Legionella species according to sputum quality were 57.1% (16/28) in Geckler 1/2 sputum, 50.0% (34/68) in Geckler 3/6 sputum, and 50.0% (4/8) in Geckler 4/5 sputum, which were not significantly different (P = 0.86). On multivariate analysis, pre-culture treatment with anti-Legionella antimicrobials (odds ratio [OR] 0.26, 95% confidence interval [CI] 0.06-0.91), Pneumonia Severity Index class ≥IV (OR 2.57 [95% CI 1.02-6.71]), and intensive care unit admission (OR 3.08, 95% CI 1.06-10.09) correlated with the ability to identify Legionella species, but sputum quality did not (OR 0.88, 95% CI 0.17-4.41). The identification rate of Legionella species in non-purulent sputum was similar to that in purulent sputum. For the diagnosis of Legionella pneumonia, sputum should be collected before administering anti-Legionella antibiotics and cultured regardless of sputum quality.


Assuntos
Legionella pneumophila , Legionella , Doença dos Legionários , Pneumonia , Humanos , Escarro , Doença dos Legionários/diagnóstico
10.
Genome Biol Evol ; 16(3)2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38478715

RESUMO

Sucking lice of the parvorder Anoplura are permanent ectoparasites with specific lifestyle and highly derived features. Currently, genomic data are only available for a single species, the human louse Pediculus humanus. Here, we present genomes of two distinct lineages, with different host spectra, of a rodent louse Polyplax serrata. Genomes of these ecologically different lineages are closely similar in gene content and display a conserved order of genes, with the exception of a single translocation. Compared with P. humanus, the P. serrata genomes are noticeably larger (139 vs. 111 Mbp) and encode a higher number of genes. Similar to P. humanus, they are reduced in sensory-related categories such as vision and olfaction. Utilizing genome-wide data, we perform phylogenetic reconstruction and evolutionary dating of the P. serrata lineages. Obtained estimates reveal their relatively deep divergence (∼6.5 Mya), comparable with the split between the human and chimpanzee lice P. humanus and Pediculus schaeffi. This supports the view that the P. serrata lineages are likely to represent two cryptic species with different host spectra. Historical demographies show glaciation-related population size (Ne) reduction, but recent restoration of Ne was seen only in the less host-specific lineage. Together with the louse genomes, we analyze genomes of their bacterial symbiont Legionella polyplacis and evaluate their potential complementarity in synthesis of amino acids and B vitamins. We show that both systems, Polyplax/Legionella and Pediculus/Riesia, display almost identical patterns, with symbionts involved in synthesis of B vitamins but not amino acids.


Assuntos
Anoplura , Legionella , Pediculus , Complexo Vitamínico B , Animais , Humanos , Filogenia , Roedores/genética , Anoplura/genética , Pediculus/genética , Especificidade de Hospedeiro/genética
11.
Ann Agric Environ Med ; 31(1): 24-28, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38549473

RESUMO

INTRODUCTION: Legionella pneumophila is the primary etiological agent of Legionnaires' disease. These are opportunistic pathogens causing lung infections by inhalation of contaminated aerosols. Controlling the presence of these bacteria in domestic distribution water systems (mainly hot water systems) is important for reducing the threat they pose to human health. Legionella pathogens are detected and quantified during routine testing of water samples according to procedures included in PN-EN ISO 11731:2017. However, these procedures are labour-intensive, and the results are obtained after a relatively long time. Implementing the Legiolert™/Quanti-Tray® test as an alternative method may constitute a good solution: it simplifies the testing procedure and significantly reduces the time necessary to obtain the final result. OBJECTIVE: The aim of the study was to compare the relative recovery of Legionella from water samples tested according to PN-EN ISO 11731:2017, and the alternative method of the most probable number (MPN) with the Legiolert™/Quanti-Tray® (IDEXX) test, and to assess the suitability of the alternative method for routine testing. MATERIAL AND METHODS: Parallel testing was conducted of 38 hot water samples to detect and determine Legionella acc. to PN-EN ISO 11731:2017 and the Legiolert™/Quanti-Tray® test. Statistical analysis of the results was performed according to PN-EN ISO 17994:2014 and the McNemar's test. RESULTS: The Legiolert™ test was confirmed to be comparable in performance to the reference standardized method in both qualitative and quantitative detection of L. pneumophila in hot water samples. CONCLUSIONS: The study confirmed that the Legiolert™ test is specific and easy to use, and may constitute an alternative to standardized procedures used in the quantification of L. pneumophila in water.


Assuntos
Água Potável , Legionella pneumophila , Legionella , Doença dos Legionários , Humanos , Microbiologia da Água , Aerossóis e Gotículas Respiratórios , Doença dos Legionários/diagnóstico , Doença dos Legionários/microbiologia
12.
J Microorg Control ; 29(1): 1-7, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38508757

RESUMO

The growth of acid-fast bacteria often hinders the detection of Legionella in water samples on agar plates by the plate culture method. We studied whether anti-tubercular agents inhibit acid-fast bacteria growth on agar plates. First, the antimicrobial activities of isoniazid, ethionamide, and ethambutol were evaluated against Mycobacterium and Legionella. We found that ethambutol at ≥ 100 µg/mL completely inhibited Mycobacterium growth, but ethambutol at 1,000 µg/mL did not inhibit Legionella growth. Next, the effect of ethambutol dissolved in acid buffer was examined. Cell suspensions of L. pneumophila and Mycobacterium spp. were mixed, and ethambutol-acid buffer was added. After 5 min, mixtures were inoculated on GVPC agar plates and incubated at 36℃ for 6 d. We found that ethambutol inhibited Mycobacterium growth on agar plates, but the Legionella colonies recovered. The effect of ethambutol was also significant in the evaluation using bathwaters. Comparing 1,302 bathwaters, the addition of ethambutol reduced the detection rate of acid-fast bacteria from 30.6% to 0% and increased the detection rate of Legionella from 7.1% to 7.5%. Ethambutol, which selectively inhibited acid-fast bacteria growth, enhanced the detection of Legionella on agar plates and will contribute to improving the accuracy of Legionella testing by the plate culture method.


Assuntos
Legionella , Etambutol/farmacologia , Ágar , Microbiologia da Água , Água
13.
J Occup Environ Hyg ; 21(4): 259-269, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38447033

RESUMO

Legionella pneumophila, the leading cause of Legionnaires' disease in the United States, is found in lakes, ponds, and streams but poses a health risk when it grows in building water systems. The growth of L. pneumophila in hot water systems of healthcare facilities poses a significant risk to patients, staff, and visitors. Hospitals and long-term care facilities account for 76% of reported Legionnaires' disease cases with mortality rates of 25%. Controlling L. pneumophila growth in hot water systems serving healthcare and hospitality buildings is currently achieved primarily by adding oxidizing chemical disinfectants. Chemical oxidants generate disinfection byproducts and can accelerate corrosion of premise plumbing materials and equipment. Alternative control methods that do not generate hazardous disinfection byproducts or accelerate corrosion are needed. L. pneumophila is an obligate aerobe that cannot sustain cellular respiration, amplify, or remain culturable when dissolved oxygen (DO) concentrations are too low (< 0.3 mg/L). An alternative method of controlling L. pneumophila growth by reducing DO levels in a hot water model system using a gas transfer membrane contactor was evaluated. A hot water model system was constructed and inoculated with L. pneumophila at DO concentrations above 0.5 mg/L. Once the model system was colonized, DO levels were incrementally reduced. Water samples were collected each week to evaluate the effect of reducing dissolved oxygen levels when all other conditions favored Legionella amplification. At DO concentrations below 0.3 mg/L, L. pneumophila concentrations were reduced by 1-log over 7 days. Under conditions in the hot water model system, at favorable temperatures and with no residual chlorine disinfectant, L. pneumophila concentrations were reduced by 1-log, indicating growth inhibition by reducing DO levels as the sole control measure. In sections of the model system where DO levels were not lowered L. pneumophila continued to grow. Reducing dissolved oxygen levels in hot water systems of healthcare and other large buildings to control L. pneumophila could also lower the risk of supplemental chemical treatment methods currently in use.


Assuntos
Desinfetantes , Legionella pneumophila , Legionella , Doença dos Legionários , Humanos , Doença dos Legionários/prevenção & controle , Abastecimento de Água , Engenharia Sanitária , Desinfetantes/farmacologia , Água/farmacologia , Microbiologia da Água , Temperatura Alta
14.
J Clin Microbiol ; 62(4): e0130523, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38511938

RESUMO

The unprecedented precision and resolution of whole genome sequencing (WGS) can provide definitive identification of infectious agents for epidemiological outbreak tracking. WGS approaches, however, are frequently impeded by low pathogen DNA recovery from available primary specimens or unculturable samples. A cost-effective hybrid capture assay for Legionella pneumophila WGS analysis directly on primary specimens was developed. DNA from a diverse range of sputum and autopsy specimens PCR-positive for L. pneumophila serogroup 1 (LPSG1) was enriched with this method, and WGS was performed. All tested specimens were determined to be enriched for Legionella reads (up to 209,000-fold), significantly improving the discriminatory power to compare relatedness when no clinical isolate was available. We found the WGS data from some enriched specimens to differ by less than five single-nucleotide polymorphisms (SNPs) when compared to the WGS data of a matched culture isolate. This testing and analysis retrospectively provided previously unconfirmed links to environmental sources for clinical specimens of sputum and autopsy lung tissue. The latter provided the additional information needed to identify the source of these culture-negative cases associated with the South Bronx 2015 Legionnaires' disease (LD) investigation in New York City. This new method provides a proof of concept for future direct clinical specimen hybrid capture enrichment combined with WGS and bioinformatic analysis during outbreak investigations.IMPORTANCELegionnaires' disease (LD) is a severe and potentially fatal type of pneumonia primarily caused by inhalation of Legionella-contaminated aerosols from man-made water or cooling systems. LD remains extremely underdiagnosed as it is an uncommon form of pneumonia and relies on clinicians including it in the differential and requesting specialized testing. Additionally, it is challenging to obtain clinical lower respiratory specimens from cases with LD, and when available, culture requires specialized media and growth conditions, which are not available in all microbiology laboratories. In the current study, a method for Legionella pneumophila using hybrid capture by RNA baiting was developed, which allowed us to generate sufficient genome resolution from L. pneumophila serogroup 1 PCR-positive clinical specimens. This new approach offers an additional tool for surveillance of future LD outbreaks where isolation of Legionella is not possible and may help solve previously unanswered questions from past LD investigations.


Assuntos
Legionella pneumophila , Legionella , Doença dos Legionários , Pneumonia , Humanos , Doença dos Legionários/diagnóstico , Estudos Retrospectivos , Legionella pneumophila/genética , Sequenciamento Completo do Genoma , Surtos de Doenças , DNA
15.
MMWR Surveill Summ ; 73(1): 1-23, 2024 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-38470836

RESUMO

Problem/Condition: Public health agencies in U.S. states, territories, and freely associated states investigate and voluntarily report waterborne disease outbreaks to CDC through the National Outbreak Reporting System (NORS). This report summarizes NORS drinking water outbreak epidemiologic, laboratory, and environmental data, including data for both public and private drinking water systems. The report presents outbreak-contributing factors (i.e., practices and factors that lead to outbreaks) and, for the first time, categorizes outbreaks as biofilm pathogen or enteric illness associated. Period Covered: 2015-2020. Description of System: CDC launched NORS in 2009 as a web-based platform into which public health departments voluntarily enter outbreak information. Through NORS, CDC collects reports of enteric disease outbreaks caused by bacterial, viral, parasitic, chemical, toxin, and unknown agents as well as foodborne and waterborne outbreaks of nonenteric disease. Data provided by NORS users, when known, for drinking water outbreaks include 1) the number of cases, hospitalizations, and deaths; 2) the etiologic agent (confirmed or suspected); 3) the implicated type of water system (e.g., community or individual or private); 4) the setting of exposure (e.g., hospital or health care facility; hotel, motel, lodge, or inn; or private residence); and 5) relevant epidemiologic and environmental data needed to describe the outbreak and characterize contributing factors. Results: During 2015-2020, public health officials from 28 states voluntarily reported 214 outbreaks associated with drinking water and 454 contributing factor types. The reported etiologies included 187 (87%) biofilm associated, 24 (11%) enteric illness associated, two (1%) unknown, and one (<1%) chemical or toxin. A total of 172 (80%) outbreaks were linked to water from public water systems, 22 (10%) to unknown water systems, 17 (8%) to individual or private systems, and two (0.9%) to other systems; one (0.5%) system type was not reported. Drinking water-associated outbreaks resulted in at least 2,140 cases of illness, 563 hospitalizations (26% of cases), and 88 deaths (4% of cases). Individual or private water systems were implicated in 944 (43%) cases, 52 (9%) hospitalizations, and 14 (16%) deaths.Enteric illness-associated pathogens were implicated in 1,299 (61%) of all illnesses, and 10 (2%) hospitalizations. No deaths were reported. Among these illnesses, three pathogens (norovirus, Shigella, and Campylobacter) or multiple etiologies including these pathogens resulted in 1,225 (94%) cases. The drinking water source was identified most often (n = 34; 7%) as the contributing factor in enteric disease outbreaks. When water source (e.g., groundwater) was known (n = 14), wells were identified in 13 (93%) of enteric disease outbreaks.Most biofilm-related outbreak reports implicated Legionella (n = 184; 98%); two nontuberculous mycobacteria (NTM) (1%) and one Pseudomonas (0.5%) outbreaks comprised the remaining. Legionella-associated outbreaks generally increased over the study period (14 in 2015, 31 in 2016, 30 in 2017, 34 in 2018, 33 in 2019, and 18 in 2020). The Legionella-associated outbreaks resulted in 786 (37%) of all illnesses, 544 (97%) hospitalizations, and 86 (98%) of all deaths. Legionella also was the outbreak etiology in 160 (92%) public water system outbreaks. Outbreak reports cited the premise or point of use location most frequently as the contributing factor for Legionella and other biofilm-associated pathogen outbreaks (n = 287; 63%). Legionella was reported to NORS in 2015 and 2019 as the cause of three outbreaks in private residences (2). Interpretation: The observed range of biofilm and enteric drinking water pathogen contributing factors illustrate the complexity of drinking water-related disease prevention and the need for water source-to-tap prevention strategies. Legionella-associated outbreaks have increased in number over time and were the leading cause of reported drinking water outbreaks, including hospitalizations and deaths. Enteric illness outbreaks primarily linked to wells represented approximately half the cases during this reporting period. This report enhances CDC efforts to estimate the U.S. illness and health care cost impacts of waterborne disease, which revealed that biofilm-related pathogens, NTM, and Legionella have emerged as the predominant causes of hospitalizations and deaths from waterborne- and drinking water-associated disease. Public Health Action: Public health departments, regulators, and drinking water partners can use these findings to identify emerging waterborne disease threats, guide outbreak response and prevention programs, and support drinking water regulatory efforts.


Assuntos
Água Potável , Legionella , Doenças Transmitidas pela Água , Humanos , Estados Unidos/epidemiologia , Microbiologia da Água , Surtos de Doenças , Abastecimento de Água , Vigilância da População
16.
Microbiol Spectr ; 12(4): e0345923, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38363136

RESUMO

Public bath facilities are a major source of Legionella infections in Japan. In this study, we performed 16S rRNA gene amplicon sequencing to characterize the bacterial community in bath and shower water from public bath facilities, along with chemical parameters, and investigated the effect of the bacterial microbiome on the presence of Legionella species. Although no significant difference in bacterial community richness was observed between bath and shower water samples, there was a remarkable difference in the bacterial community structure between them. Distance-based redundancy analysis revealed that several factors (free residual chlorine, pH, and conductivity) were correlated with the bacterial community in bath water. The most abundant bacterial genera in the samples were Pseudomonas (13.7%) in bath water and Phreatobacter (13.6%) in shower water, as indicated by the taxonomic composition, and the dominant bacteria differed between these environmental samples. Legionella pneumophila was the most frequently detected Legionella species, with additional 15 other Legionella species detected in water samples. In Legionella-positive water samples, several unassigned and uncultured bacteria were enriched together. In addition, the co-occurrence network showed that Legionella was strongly interconnected with two uncultured bacteria. Corynebacterium and Sphingomonas negatively correlated with Legionella species. The present study reveals the ecology of Legionella species, especially their interactions with other bacteria that are poorly understood to date. IMPORTANCE: Public bath facilities are major sources of sporadic cases and outbreaks of Legionella infections. Recently, 16S rRNA gene amplicon sequencing has been used to analyze bacterial characteristics in various water samples from both artificial and natural environments, with a particular focus on Legionella bacterial species. However, the relationship between the bacterial community and Legionella species in the water from public bath facilities remains unclear. In terms of hygiene management, it is important to reduce the growth of Legionella species by disinfecting the water in public bath facilities. Our findings contribute to the establishment of appropriate hygiene management practices and provide a basis for understanding the potential health effects of using bath and shower water available in public bath facilities.


Assuntos
Legionella pneumophila , Legionella , Legionelose , Microbiota , Humanos , Legionella/genética , RNA Ribossômico 16S/genética , Água , Genes de RNAr , Microbiologia da Água , Legionella pneumophila/genética
17.
Eur J Clin Microbiol Infect Dis ; 43(5): 991-997, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38379053

RESUMO

Fourier-transform infrared (FTIR) spectroscopy using the IR Biotyper and core genome single nucleotide polymorphism (cgSNP) analysis were performed on 12 Legionella isolates associated with an outbreak at a spa house in Kanagawa Prefecture, Japan, and 3 non-outbreak isolates. The discriminative power of FTIR spectroscopy for 48-h incubation conditions of L. pneumophila in this outbreak was lower than cgSNP-based typing but higher than serogroup typing. FTIR spectroscopy could screen outbreak isolates from a group of genetically related isolates and may be useful as an initial typing method in Legionella outbreak investigations.


Assuntos
Surtos de Doenças , Legionelose , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Humanos , Japão/epidemiologia , Legionelose/epidemiologia , Legionelose/diagnóstico , Legionelose/microbiologia , Polimorfismo de Nucleotídeo Único , Técnicas de Tipagem Bacteriana/métodos , Legionella pneumophila/genética , Legionella pneumophila/isolamento & purificação , Legionella pneumophila/classificação , Legionella/genética , Legionella/isolamento & purificação , Legionella/classificação
18.
mBio ; 15(3): e0322123, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38335095

RESUMO

The survival of Legionella spp. as intracellular pathogens relies on the combined action of protein effectors delivered inside their eukaryotic hosts by the Dot/Icm (defective in organelle trafficking/intracellular multiplication) type IVb secretion system. The specific repertoire of effector arsenals varies dramatically across over 60 known species of this genera with Legionella pneumophila responsible for most cases of Legionnaires' disease in humans encoding over 360 Dot/Icm effectors. However, a small subset of "core" effectors appears to be conserved across all Legionella species raising an intriguing question of their role in these bacteria's pathogenic strategy, which for most of these effectors remains unknown. L. pneumophila Lpg0103 effector, also known as VipF, represents one of the core effector families that features a tandem of Gcn5-related N-acetyltransferase (GNAT) domains. Here, we present the crystal structure of the Lha0223, the VipF representative from Legionella hackeliae in complex with acetyl-coenzyme A determined to 1.75 Å resolution. Our structural analysis suggested that this effector family shares a common fold with the two GNAT domains forming a deep groove occupied by residues conserved across VipF homologs. Further analysis suggested that only the C-terminal GNAT domain of VipF effectors retains the active site composition compatible with catalysis, whereas the N-terminal GNAT domain binds the ligand in a non-catalytical mode. We confirmed this by in vitro enzymatic assays which revealed VipF activity not only against generic small molecule substrates, such as chloramphenicol, but also against poly-L-lysine and histone-derived peptides. We identified the human eukaryotic translation initiation factor 3 (eIF3) complex co-precipitating with Lpg0103 and demonstrated the direct interaction between the several representatives of the VipF family, including Lpg0103 and Lha0223 with the K subunit of eIF3. According to our data, these interactions involve primarily the C-terminal tail of eIF3-K containing two lysine residues that are acetylated by VipF. VipF catalytic activity results in the suppression of eukaryotic protein translation in vitro, revealing the potential function of VipF "core" effectors in Legionella's pathogenic strategy.IMPORTANCEBy translocating effectors inside the eukaryotic host cell, bacteria can modulate host cellular processes in their favor. Legionella species, which includes the pneumonia-causing Legionella pneumophila, encode a widely diverse set of effectors with only a small subset that is conserved across this genus. Here, we demonstrate that one of these conserved effector families, represented by L. pneumophila VipF (Lpg0103), is a tandem Gcn5-related N-acetyltransferase interacting with the K subunit of human eukaryotic initiation factor 3 complex. VipF catalyzes the acetylation of lysine residues on the C-terminal tail of the K subunit, resulting in the suppression of eukaryotic translation initiation factor 3-mediated protein translation in vitro. These new data provide the first insight into the molecular function of this pathogenic factor family common across Legionellae.


Assuntos
Legionella pneumophila , Legionella , Doença dos Legionários , Humanos , Acetiltransferases/metabolismo , Fator de Iniciação 3 em Eucariotos/metabolismo , Lisina/metabolismo , Fator de Iniciação 3 em Procariotos/metabolismo , Legionella/genética , Legionella pneumophila/genética , Biossíntese de Proteínas , Proteínas de Bactérias/metabolismo
19.
Water Res ; 253: 121109, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38377920

RESUMO

Running cold and hot water in buildings is a widely established commodity. However, interests regarding hygiene and microbiological aspects had so far been focussed on cold water. Little attention has been given to the microbiology of domestic hot-water installations (DHWIs), except for aspects of pathogenic Legionella. World-wide, regulations consider hot (or warm) water as 'heated drinking water' that must comply (cold) drinking water (DW) standards. However, the few reports that exist indicate presence and growth of microbial flora in DHWIs, even when supplied with water with disinfectant residual. Using flow cytometric (FCM) total cell counting (TCC), FCM-fingerprinting, and 16S rRNA-gene-based metagenomic analysis, the characteristics and composition of bacterial communities in cold drinking water (DW) and hot water from associated boilers (operating at 50 - 60 °C) was studied in 14 selected inhouse DW installations located in Switzerland and Austria. A sampling strategy was applied that ensured access to the bulk water phase of both, supplied cold DW and produced hot boiler water. Generally, 1.3- to 8-fold enhanced TCCs were recorded in hot water compared to those in the supplied cold DW. FCM-fingerprints of cold and corresponding hot water from individual buildings indicated different composition of cold- and hot-water microbial floras. Also, hot waters from each of the boilers sampled had its own individual FCM-fingerprint. 16S rRNA-gene-based metagenomic analysis confirmed the marked differences in composition of microbiomes. E.g., in three neighbouring houses supplied from the same public network pipe each hot-water boiler contained its own thermophilic bacterial flora. Generally, bacterial diversity in cold DW was broad, that in hot water was restricted, with mostly thermophilic strains from the families Hydrogenophilaceae, Nitrosomonadaceae and Thermaceae dominating. Batch growth assays, consisting of cold DW heated up to 50 - 60 °C and inoculated with hot water, resulted in immediate cell growth with doubling times between 5 and 10 h. When cold DW was used as an inoculum no significant growth was observed. Even boilers supplied with UVC-treated cold DW contained an actively growing microbial flora, suggesting such hot-water systems as autonomously operating, thermophilic bioreactors. The generation of assimilable organic carbon from dissolved organic carbon due to heating appears to be the driver for growth of thermophilic microbial communities. Our report suggests that a man-made microbial ecosystem, very close to us all and of potential hygienic importance, may have been overlooked so far. Despite consumers having been exposed to microbial hot-water flora for a long time, with no major pathogens so far been associated specifically with hot-water usage (except for Legionella), the role of harmless thermophiles and their interaction with potential human pathogens able to grow at elevated temperatures in DHWIs remains to be investigated.


Assuntos
Água Potável , Legionella , Humanos , Água Potável/microbiologia , RNA Ribossômico 16S , Ecossistema , Abastecimento de Água , Bactérias/genética , Microbiologia da Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA