RESUMO
Legionellosis is a respiratory infection caused by Legionella sp. that is found in water and soil. Infection may cause pneumonia (Legionnaires' Disease) and a milder form (Pontiac Fever). Legionella colonizes water systems and results in exposure by inhalation of aerosolized bacteria. The incubation period ranges from 2 to 14 days. Precipitation and humidity may be associated with increased risk. We used Medicare records from 1999 to 2020 to identify hospitalizations for legionellosis. Precipitation, temperature, and relative humidity were obtained from the PRISM Climate Group for the zip code of residence. We used a time-stratified bi-directional case-crossover design with lags of 20 days. Data were analyzed using conditional logistic regression and distributed lag non-linear models. A total of 37 883 hospitalizations were identified. Precipitation and relative humidity at lags 8 through 13 days were associated with an increased risk of legionellosis. The strongest association was precipitation at day 10 lag (OR = 1.08, 95% CI = 1.05-1.11 per 1 cm). Over 20 days, 3 cm of precipitation increased the odds of legionellosis over four times. The association was strongest in the Northeast and Midwest and during summer and fall. Precipitation and humidity were associated with hospitalization among Medicare recipients for legionellosis at lags consistent with the incubation period for infection.
Assuntos
Legionelose , Medicare , Tempo (Meteorologia) , Humanos , Estados Unidos/epidemiologia , Legionelose/epidemiologia , Medicare/estatística & dados numéricos , Idoso , Feminino , Masculino , Idoso de 80 Anos ou mais , Estudos Cross-Over , Hospitalização/estatística & dados numéricos , Fatores de Risco , Legionella/isolamento & purificaçãoRESUMO
Introduction: Nosocomial structures pose a high risk of Legionella spp. contamination due to complex water systems with challenging disinfection; moreover, the risk of severe legionellosis as a consequence of nosocomial exposure is very high in settings characterized by vulnerable patient conditions. Methods: In the present work, we described the results of 7 years of environmental surveillance in a reference hospital in Liguria, in which a specific water safety plan (WSP) has been implemented in 2017, including data collected during the COVID-19 pandemic. Results: During the study period, 1190 water samples were collected, of which 277 (23.3%) tested positive for Legionella spp. Positive samples with concentration values above 1,000 CFU/l were 184 (66.4%). Based on the new structure categorization contained in the WSP, hospital buildings classified as at "very high" risk resulted the most affected structures over the entire study period; however, the absolute number of positive samples greatly decreased over time, from 61 contaminated water samples in 2017 to only 9 in 2023. Conclusions: Our findings prompted the reinforcement of control and prevention measures, affirming the appropriateness of risk-category classification. Indeed, the majority of contamination cases were associated with the water networks of buildings classified as "very high" risk.
Assuntos
Monitoramento Ambiental , Hospitais Universitários , Legionella , Microbiologia da Água , Legionella/isolamento & purificação , Itália/epidemiologia , Humanos , COVID-19/epidemiologia , COVID-19/prevenção & controle , Infecção Hospitalar/prevenção & controle , Infecção Hospitalar/epidemiologia , Legionelose/epidemiologia , Legionelose/prevenção & controle , SARS-CoV-2RESUMO
Legionella pneumophila is ubiquitous and sporadically infects humans causing Legionnaire's disease (LD). Globally, reported cases of LD have risen fourfold from 2000 to 2014. In 2016, Sydney, Australia was the epicenter of an outbreak caused by L. pneumophila serogroup 1 (Lpsg1). Whole-genome sequencing was instrumental in identifying the causal clone which was found in multiple locations across the city. This study examined the epidemiology of Lpsg1 in an urban environment, assessed typing schemes to classify resident clones, and investigated the association between local climate variables and LD outbreaks. Of 223 local Lpsg1 isolates, we identified dominant clones with one clone isolated from patients in high frequency during outbreak investigations. The core genome multi-locus sequence typing scheme was the most reliable in identifying this Lpsg1 clone. While an increase in humidity and rainfall was found to coincide with a rise in LD cases, the incidence of the major L. pneumophila outbreak clone did not link to weather phenomena. These findings demonstrated the role of high-resolution typing and weather context assessment in determining source attribution for LD outbreaks in urban settings, particularly when clinical isolates remain scarce.IMPORTANCEWe investigated the genomic and meteorological influences of infections caused by Legionella pneumophila in Sydney, Australia. Our study contributes to a knowledge gap of factors that drive outbreaks of legionellosis compared to sporadic infections in urban settings. In such cases, clinical isolates can be rare, and thus, other data are needed to inform decision-making around control measures. The study revealed that core genome multi-locus sequence typing is a reliable and adaptable technique when investigating Lpsg1 outbreaks. In Sydney, the genomic profile of Lpsg1 was dominated by a single clone, which was linked to numerous community cases over a period of 40 years. Interestingly, the peak in legionellosis cases during Autumn was not associated with this prevalent outbreak clone. Incorporating meteorological data with Lpsg1 genomics can support risk assessment strategies for legionellosis in urban environments, and this approach may be relevant for other densely populated regions globally.
Assuntos
Surtos de Doenças , Genômica , Legionella pneumophila , Doença dos Legionários , Humanos , Legionella pneumophila/genética , Legionella pneumophila/classificação , Legionella pneumophila/isolamento & purificação , Doença dos Legionários/epidemiologia , Doença dos Legionários/microbiologia , Austrália/epidemiologia , Cidades/epidemiologia , Tipagem de Sequências Multilocus , Sequenciamento Completo do Genoma , Legionelose/epidemiologia , Legionelose/microbiologia , New South Wales/epidemiologia , Tempo (Meteorologia)RESUMO
Wastewater treatment plants (WWTPs) are suspected reservoirs of Legionella pneumophila (Lp). The required aeration and mixing steps lead to the emission and dispersion of bioaerosols potentially harboring Lp. The aim of the project is to evaluate municipal WWTPs as a possible source of legionellosis through the statistical analysis of case clusters. A space-time scanning statistical method was implemented in SaTScan software to identify and analyze WWTPs located within and close to spatiotemporal clusters of legionellosis detected in Quebec between 2016 and 2020. In parallel, WWTPs were ranked according to their pollutant load, flow rate and treatment type. These parameters were used to evaluate the WWTP susceptibility to generate and disperse bioaerosols. Results show that 37 of the 874 WWTPs are located inside a legionellosis cluster study zone, including six of the 40 WWTPs ranked most susceptible. In addition, two susceptible WWTPs located within an extended area of 2.5 km from the study zone (2.5-km buffer) were included, for a total of 39 WWTPs. The selected 39 WWTPs were further studied to document proximity of population, dominant wind direction, and surrounding water quality. Samples collected from the influent and the effluent of six selected WWTPs revealed the presence of Legionella spp. in 92.3% of the samples. Lp and Lp serogroupg 1 (Lp sg1) were detected below the limit of quantification in 69% and 46% of the samples, respectively. The presence of Legionella in wastewater and the novel statistical approach presented here provides information to the public health authorities regarding the investigation of WWTPs as a possible source of Legionella exposure, sporadic cases, and clusters of legionellosis.
Assuntos
Monitoramento Ambiental , Legionelose , Águas Residuárias , Legionelose/epidemiologia , Humanos , Quebeque/epidemiologia , Legionella pneumophila , Purificação da Água , Microbiologia da Água , Eliminação de Resíduos LíquidosRESUMO
Fourier-transform infrared (FTIR) spectroscopy using the IR Biotyper and core genome single nucleotide polymorphism (cgSNP) analysis were performed on 12 Legionella isolates associated with an outbreak at a spa house in Kanagawa Prefecture, Japan, and 3 non-outbreak isolates. The discriminative power of FTIR spectroscopy for 48-h incubation conditions of L. pneumophila in this outbreak was lower than cgSNP-based typing but higher than serogroup typing. FTIR spectroscopy could screen outbreak isolates from a group of genetically related isolates and may be useful as an initial typing method in Legionella outbreak investigations.
Assuntos
Surtos de Doenças , Legionelose , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Humanos , Japão/epidemiologia , Legionelose/epidemiologia , Legionelose/diagnóstico , Legionelose/microbiologia , Polimorfismo de Nucleotídeo Único , Técnicas de Tipagem Bacteriana/métodos , Legionella pneumophila/genética , Legionella pneumophila/isolamento & purificação , Legionella pneumophila/classificação , Legionella/genética , Legionella/isolamento & purificação , Legionella/classificaçãoRESUMO
Legionellosis is a disease caused by the bacterium Legionella that most commonly presents as Legionnaires' disease (LD), a severe form of pneumonia. From 2015 to 2019, an average of 438 LD cases per year were reported in Canada. However, it is believed that the actual number of cases is much higher, since LD may be underdiagnosed and underreported. The purpose of this study was to develop an estimate of the true incidence of illnesses, hospitalizations, and deaths associated with LD in Canada. Values were derived using a stochastic model, based on Canadian surveillance data from 2015 to 2019, which were scaled up to account for underdiagnosis and underreporting. Overall, there were an estimated 1,113 (90% CrI: 737-1,730) illnesses, 1,008 (90% CrI: 271-2,244) hospitalizations, and 34 (90% CrI: 4-86) deaths due to domestically acquired waterborne LD annually in Canada from 2015 to 2019. It was further estimated that only 36% of illnesses and 39% of hospitalizations and deaths were captured in surveillance, and that 22% of illnesses were caused by Legionella serogroups and species other than Legionella pneumophila serogroup 1 (non-Lp1). This study highlights the true burden and areas for improvement in Canada's surveillance and detection of LD.
Assuntos
Legionella pneumophila , Legionella , Legionelose , Doença dos Legionários , Humanos , Doença dos Legionários/epidemiologia , Doença dos Legionários/microbiologia , Canadá/epidemiologia , Legionelose/epidemiologia , Legionelose/microbiologia , Efeitos Psicossociais da DoençaRESUMO
OBJECTIVES: On September 23, 2019, the North Carolina Division of Public Health identified a legionellosis increase in western North Carolina; most patients had recently attended the North Carolina Mountain State Fair. We conducted a source investigation. METHODS: Cases were fair attendees with laboratory-confirmed legionellosis and symptom onset within 2 to 14 days (Legionnaires' disease) or ≤3 days (Pontiac fever). We conducted a case-control study matching cases to non-ill fair attendees as control participants and an environmental investigation, and we performed laboratory testing (Legionella bacteria culture and polymerase chain reaction) of 27 environmental samples from fairgrounds and hot tubs and 14 specimens from case patients. We used multivariable unconditional logistic regression models to calculate adjusted odds ratios for potential Legionella exposure sources and risk factors. RESULTS: Of 136 people identified with fair-associated legionellosis, 98 (72%) were hospitalized and 4 (3%) died. Case patients were more likely than control participants to report walking by hot tub displays (adjusted odds ratio = 10.0; 95% CI, 4.2-24.1). Complete hot tub water treatment records were not kept, precluding evaluation of water maintenance conducted on display hot tubs. Legionella pneumophila sequence types (STs) were consistent among 10 typed clinical specimens (ST224) but distinct from the only positive environmental sample from the fair (ST7 and ST8). CONCLUSIONS: Hot tub displays were identified as the most likely outbreak source, making this the largest hot tub-associated Legionnaires' disease outbreak worldwide. Following the investigation, the North Carolina Division of Public Health and the Centers for Disease Control and Prevention released guidance on mitigating risk of Legionella exposure from hot tub displays. Results highlight the importance of properly maintaining equipment that aerosolizes water, including hot tubs intended for display purposes only.
Assuntos
Legionelose , Doença dos Legionários , Humanos , Doença dos Legionários/epidemiologia , Estudos de Casos e Controles , North Carolina/epidemiologia , Legionelose/epidemiologia , Legionelose/complicações , Surtos de Doenças , Microbiologia da ÁguaRESUMO
Legionella is an important waterborne pathogen that causes legionellosis. Public baths are considered the primary cause of legionellosis infection in Japan. We investigated the prevalence and genetic distribution of 338 Legionella spp. isolates from 81 public bath facilities, including 35 hot springs and 46 other facilities, through annual periodic surveillance in Kobe, Japan, from 2016 to 2021. In addition, the genotypes of nine clinical strains of unknown infectious source from the same period were compared to those of bathwater isolates. We elucidated the differences in the distribution of Legionella species, serogroups, and genotypes between hot springs and other public baths. Legionella israelensis, L. londiniensis, and L. micdadei colonized hot springs along with L. pneumophila. The minimum spanning tree analysis based on multiple-locus variable number tandem repeat analysis (MLVA) also identified four major clonal complexes (CCs) in L. pneumophila SG1 and found that CC1 of the four CCs is a specific novel genotype with the lag-1 gene in hot springs. The same MLVA genotypes and sequence types as those of the clinical strains were not present among the strains isolated from bath water. Thus, our surveillance is useful for estimating the sources of legionellosis infection in Japan and developing prevention strategies.
Assuntos
Legionella pneumophila , Legionella , Legionelose , Humanos , Legionella pneumophila/genética , Japão/epidemiologia , Prevalência , Microbiologia da Água , Legionella/genética , Legionelose/epidemiologiaRESUMO
Objectives: The aim of this study is to compare the epidemiological situation of legionellosis in Poland in 2018-2021 to prior years, taking into account the impact of the COVID-19 pandemic in 2020-2021. Material and methods: The assessment is based on national surveillance data published in the annual bulletin "Infectious Diseases and Poisons in Poland" from 2013 to 2021, as well as data from Legionnaires' disease case reports collected and sent to the Department of Epidemiology of Infectious Diseases and Surveillance NIPH NIH - NRI by sanitary and epidemiological stations or submitted to EpiBase. Results: In Poland, both Legionnaires' disease (an acute infection that progresses to pneumonia) and Pontiac fever (a mild, flu-like sickness) are reported. In 2018-2021, a total of 255 cases of legionellosis were registered, including 236 cases of Legionnaires' disease and 19 cases of Pontiac fever. Each year, there was an increase in the number of notifications compared to the annual median number of cases from 2013-2017. The annual incidence rate in 2019 (0.23 per 100,000 population) was the highest since the start of legionellosis case registration in Poland. It declined again during the years of the COVID-19 pandemic. The notifications occurred throughout the country, but the highest notification rate was observed in the western belt of voivodeships. Pomorskie reported the highest incidence, accounting for more than 20% of all registered cases. The median incidence of Legionnaires' disease in men (0.23 per 100,000) was more than twice that of women (0.10), with the highest incidence (0.58) recorded in men 65 years of age or older. All indigenous cases of Legionnaires' disease were sporadic; all but three patients were hospitalized. State Sanitary Inspection reported 26 fatal cases of Legionnaires' disease (mortality = 11%). Twenty-four cases were linked to contaminated water systems in health-care settings, and 21 cases were likely associated with travel abroad. Summary and conclusions: Although the number of notifications has increased in recent years, Legionnaires' disease is still an infrequently diagnosed respiratory infection in Poland, and the reported incidence remains one of the lowest in the entire EU. The most affected demographic group is men aged 65 and older. Improving the early diagnosis of Legionnaires' disease in healthcare settings remains a priority.
Assuntos
COVID-19 , Doenças Transmissíveis , Legionelose , Doença dos Legionários , Masculino , Humanos , Feminino , Idoso , Doença dos Legionários/diagnóstico , Doença dos Legionários/epidemiologia , Polônia/epidemiologia , Pandemias , Surtos de Doenças , Sistema de Registros , COVID-19/epidemiologia , Legionelose/epidemiologia , Incidência , Doenças Transmissíveis/epidemiologiaRESUMO
Over the past two decades, the incidence of legionellosis has been steadily increasing in the United States though there is noclear explanation for the main factors driving the increase. While legionellosis is the leading cause of waterborne outbreaks in the US, most cases are sporadic and acquired in community settings where the environmental source is never identified. This scoping review aimed to summarise the drivers of infections in the USA and determine the magnitude of impact each potential driver may have. A total of 1,738 titles were screened, and 18 articles were identified that met the inclusion criteria. Strong evidence was found for precipitation as a major driver, and both temperature and relative humidity were found to be moderate drivers of incidence. Increased testing and improved diagnostic methods were classified as moderate drivers, and the ageing U.S. population was a minor driver of increasing incidence. Racial and socioeconomic inequities and water and housing infrastructure were found to be potential factors explaining the increasing incidence though they were largely understudied in the context of non-outbreak cases. Understanding the complex relationships between environmental, infrastructure, and population factors driving legionellosis incidence is important to optimise mitigation strategies and public policy.
Assuntos
Legionelose , Doença dos Legionários , Estados Unidos/epidemiologia , Humanos , Incidência , Legionelose/epidemiologia , Surtos de Doenças , Temperatura , Doença dos Legionários/epidemiologiaRESUMO
Legionellosis is a respiratory disease of public health concern. The bacterium Legionella pneumophila is the etiologic agent responsible for >90% of legionellosis cases in the United States. Legionellosis transmission primarily occurs through the inhalation or aspiration of contaminated water aerosols or droplets. Therefore, a thorough understanding of L. pneumophila detection methods and their performance in various water quality conditions is needed to develop preventive measures. Two hundred and nine potable water samples were collected from taps in buildings across the United States. L. pneumophila was determined using three culture methods: Buffered Charcoal Yeast Extract (BCYE) culture with Matrix-assisted Laser Desorption/Ionization Mass Spectrometry (MALDI-MS) identification, Legiolert® 10- and 100-mL tests, and one molecular method: quantitative Polymerase Chain Reaction (qPCR) assay. Culture and molecular positive results were confirmed by secondary testing including MALDI-MS. Eight water quality variables were studied, including source water type, secondary disinfectant, total chlorine residual, heterotrophic bacteria, total organic carbon (TOC), pH, water hardness, cold- and hot-water lines. The eight water quality variables were segmented into 28 categories, based on scale and ranges, and method performance was evaluated in each of these categories. Additionally, a Legionella genus qPCR assay was used to determine the water quality variables that promote or hinder Legionella spp. occurrence. L. pneumophila detection frequency ranged from 2 to 22% across the methods tested. Method performance parameters of sensitivity, specificity, positive and negative predictive values, and accuracy were >94% for the qPCR method but ranged from 9 to 100% for the culture methods. Water quality influenced L. pneumophila determination by culture and qPCR methods. L. pneumophila qPCR detection frequencies positively correlated with TOC and heterotrophic bacterial counts. The source water-disinfectant combination influenced the proportion of Legionella spp. that is L. pneumophila. Water quality influences L. pneumophila determination. To accurately detect L. pneumophila, method selection should consider the water quality in addition to the purpose of testing (general environmental monitoring versus disease-associated investigations).
Assuntos
Desinfetantes , Legionella pneumophila , Legionella , Legionelose , Humanos , Qualidade da Água , Legionelose/epidemiologia , Legionelose/microbiologia , Legionelose/prevenção & controle , Microbiologia da Água , Abastecimento de ÁguaRESUMO
Legionellosis, notably Legionnaires' disease, is recognized globally and in New Zealand (Aotearoa) as a major cause of community-acquired pneumonia. We analyzed the temporal, geographic, and demographic epidemiology and microbiology of Legionnaires' disease in New Zealand by using notification and laboratory-based surveillance data for 2000â2020. We used Poisson regression models to estimate incidence rate ratios and 95% CIs to compare demographic and organism trends over 2 time periods (2000-2009 and 2010-2020). The mean annual incidence rate increased from 1.6 cases/100,000 population for 2000-2009 to 3.9 cases/100,000 population for 2010-2020. This increase corresponded with a change in diagnostic testing from predominantly serology with some culture to almost entirely molecular methods using PCR. There was also a marked shift in the identified dominant causative organism, from Legionella pneumophila to L. longbeachae. Surveillance for legionellosis could be further enhanced by greater use of molecular typing of isolates.
Assuntos
Legionella pneumophila , Legionelose , Doença dos Legionários , Humanos , Doença dos Legionários/diagnóstico , Doença dos Legionários/epidemiologia , Doença dos Legionários/microbiologia , Nova Zelândia/epidemiologia , Incidência , Legionelose/diagnóstico , Legionelose/epidemiologia , Legionelose/microbiologiaRESUMO
OBJECTIVE: To identify and control a source of Legionella in Sydney CBD. METHODS: Clinical, epidemiological, environmental and genomic techniques were employed to identify cases and the source of Legionella. RESULTS: Eleven legionellosis cases were linked to Sydney CBD with a median age of 69 years. All were hospitalised and had risk factors for Legionella infection. Eight of 11 cases identified as male. Genomic analysis linked three cases to a contaminated cooling water source in Sydney CBD, with a further case infected with a similar strain to that found in Sydney CBD. Another case, although epidemiologically linked to Sydney CBD, was infected with a genomically different strain to that found in Sydney CBD. Six other cases had no viable sample for genomic analysis. CONCLUSION/IMPLICATIONS FOR PUBLIC HEALTH: An outbreak of legionellosis is a serious public health threat that requires rapid investigation and environmental control. We were able to identify a source in Sydney CBD through the application of clinical, epidemiological, environmental and genomic techniques. Genomic analysis is a powerful tool that can be used to confirm the source location but requires close collaboration between clinicians, public health units and microbiologists to recover viable sputum cultures from cases diagnosed with legionellosis.
Assuntos
Legionella , Legionelose , Masculino , Humanos , Idoso , Legionelose/diagnóstico , Legionelose/epidemiologia , Fatores de Risco , Surtos de Doenças , Poluição da ÁguaRESUMO
The reported rate of legionellosis is increasing in Aotearoa New Zealand (NZ) with most cases community-acquired, sporadic (non-outbreak) and without an identifiable source. This analysis used two datasets to describe the environmental sources that contribute to Legionella in NZ, based on linkages with outbreaks and sporadic clinical cases, and analysis of environmental testing data. These findings highlight the need for enhanced environmental investigation of clinical cases and outbreaks. There is also a need for systematic surveillance testing of high-risk source environments to support more rigorous controls to prevent legionellosis.
Assuntos
Legionella , Legionelose , Humanos , Legionella/genética , Nova Zelândia/epidemiologia , Microbiologia da Água , Legionelose/epidemiologia , Legionelose/prevenção & controle , Surtos de DoençasRESUMO
OBJECTIVES: According to current knowledge about legionella transmission, healthcare workers (HCWs) are at an increased risk of exposure. The aim of this research was to systematically review the literature about HCWs' exposure to legionella and establish whether there is an occupational risk. STUDY DESIGN: This was a systematic review and meta-analysis. METHODS: PubMed, Scopus and Web of Science were searched to identify studies regarding the occupational risk of legionellosis for HCWs. Keywords used in the search were 'Legionella pneumophila', 'occupational medicine', 'occupational' and 'risk'. Selected studies were reviewed to assess the quality and meta-analysed. Finally, the nine epidemiological principles of Bradford-Hill criteria were used to assess whether legionellosis could be considered an occupational risk for HCWs. RESULTS: The search strategy retrieved 124 studies, and 10 studies were included in the present review. The overall study quality was low. The pooled odds ratio estimate was 2.45 (95% confidence interval: 1.52-3.96). The assessment using Bradford-Hill criteria showed that only two criteria (plausibility and coherence) were met, which is insufficient to establish an occupational risk. CONCLUSIONS: This systematic review suggests that there is a higher risk of legionella exposure for HCWs, but there is currently no clinical evidence. Further studies with appropriate study design are needed to determine whether legionella infection is an occupational risk for HCWs.
Assuntos
Legionella , Legionelose , Doenças Profissionais , Exposição Ocupacional , Humanos , Setor de Assistência à Saúde , Doenças Profissionais/epidemiologia , Doenças Profissionais/etiologia , Exposição Ocupacional/efeitos adversos , Legionelose/epidemiologiaRESUMO
INTRODUCTION: During the COVID-19 pandemic, the incidence of many droplet-transmitted infections decreased due to increased mask-wearing and social distancing. Contrastingly, there has been concern that COVID-19 countermeasures, such as lockdowns, may increase legionellosis incidence via water stagnation. During the pandemic in Japan, four state of emergency declarations were imposed between 2020 and 2021, which makes it particularly suitable to test this hypothesis. METHODS: We use country-level surveillance data from the National Institute of Infectious Diseases to track the relative incidence of legionellosis compared to invasive pneumococcal disease (IPD) during the COVID-19 pandemic in Japan, with a focus on the periods just after state of emergency declarations were lifted. RESULTS: The absolute number of legionellosis and IPD cases decreased in 2020 and 2021 compared to previous years. The average relative incidence of legionellosis as well as the variance of the relative incidence significantly increased during the pandemic compared to previous years. There were no increases in the relative incidence of legionellosis during the periods immediately following emergency declaration liftings, but the relative incidence did increase considerably during the first two states of emergency. CONCLUSIONS: COVID-19 countermeasures appear more effective at decreasing the incidence of human-to-human transmitted infections, such as IPD, compared to environmentally-transmitted infections, such as legionellosis. Though no evidence was found to suggest that legionellosis cases increased after state of emergency declarations, public health efforts should continue to emphasize the importance of routine sanitation and water system maintenance to prevent water stagnation and Legionella spp. contamination.
Assuntos
COVID-19 , Legionelose , Infecções Pneumocócicas , Humanos , COVID-19/epidemiologia , Pandemias , Incidência , Japão/epidemiologia , Controle de Doenças Transmissíveis , Legionelose/epidemiologia , Infecções Pneumocócicas/epidemiologia , ÁguaRESUMO
BACKGROUND: Legionellosis is a collective term used for disease caused by Legionella species which result in community and hospital acquired pneumonia worldwide. The aim of this analysis was to describe the epidemiology of legionellosis hospitalisations in Aotearoa New Zealand (NZ) over a 21-year period and quantify the health care costs. METHOD: This study combined national legionellosis notification and hospital discharge data that were linked via the National Health Index (NHI) to provide a more complete dataset of hospitalised cases. The direct cost of hospital care was estimated by multiplying the diagnosis-related group cost-weight by the national price and inflating to 2020/2021 values. RESULTS: There were 1479 records matched across notifications and discharge databases, including 990 with principal and 489 with additional diagnosis of legionellosis. Incidence rose to an average of 143 cases per annum for 2016-2020, a rate of 3·2/100,000. The median LOS was 6 days (IQR 4-13·5) with direct costs of $2·1 million per annum over that period. Rates were highest in those aged 65 years and above, male, and of European/Other ethnicity. Hospitalisations showed a peak in spring and summer. CONCLUSION: The rate of hospitalised legionellosis in New Zealand rose from 2000 to 2015, largely reflecting improved diagnosis. This preventable disease results in substantial health care costs. Greater efforts are needed to identify and control sources of exposure. Surveillance could be improved by routine integration of notification and hospital discharge data.
Assuntos
Legionella , Legionelose , Humanos , Masculino , Nova Zelândia/epidemiologia , Legionelose/epidemiologia , Legionelose/etiologia , Custos de Cuidados de Saúde , HospitalizaçãoRESUMO
In August 2021, a legionellosis outbreak involving 7 persons occurred within a 500-meter radius in the Montérégie region of Québec, Canada. Near real-time modeling of wind direction along with epidemiologic and environmental investigations identified the possible source. Modeling wind direction could help identify likely Legionella pneumophila sources during legionellosis outbreaks.
Assuntos
Legionella pneumophila , Legionelose , Doença dos Legionários , Humanos , Quebeque/epidemiologia , Legionelose/epidemiologia , Legionella pneumophila/genética , Surtos de Doenças , Canadá , Microbiologia da Água , Doença dos Legionários/epidemiologiaRESUMO
Objective: This study describes characteristics of the legionellosis cases occurring between 2010 and 2021 in the Northern Territory (NT), Australia. Methods: We retrospectively reviewed 53 cases of legionellosis during the defined period and documented patient and clinical characteristics, diagnostics, and seasonality of infection. Results: All cases were sporadic. The incidence rate in the NT was higher than the Australian median rate (2.1 and 1.5 per 100,000 population per year respectively). Aboriginal and Torres Strait Islander patients presented at a younger age than did non-Indigenous patients (median 41 and 60 years of age respectively), and overall there was a male preponderance. There was a higher proportion of legionellosis in the months with increased humidity, with a greater number of L. longbeachae infections detected overall (59%) than of L. pneumophila (41%). The majority of cases were diagnosed serologically (57% of L. pneumophilia and 93% of L. longbeachae ). Conclusions: Legionellosis in the NT is more common, seasonal, and may be underreported due to current reliance on serological testing for diagnosis. The higher incidence of legionellosis, and the younger age of Aboriginal and Torres Strait Islander patients of the NT, have public health implications, given that the clinical presentation of legionellosis is indistinguishable from other forms of pneumonia.
Assuntos
Legionelose , Havaiano Nativo ou Outro Ilhéu do Pacífico , Adulto , Humanos , Incidência , Legionelose/diagnóstico , Legionelose/epidemiologia , Masculino , Pessoa de Meia-Idade , Northern Territory/epidemiologia , Estudos RetrospectivosRESUMO
This study examined 184 legionellosis outbreaks in the United States reported to the Centers for Disease Control and Prevention's Waterborne Disease and Outbreak Surveillance System, from 2001 to 2017. Drinking water characteristics examined include source water type, disinfectant type, exposure setting, geographical distribution by U.S. Census Divisions, and the public water system size (population served). This study found that most of the reported drinking water-associated legionellosis outbreaks occurred in eastern United States, including 35% in the South Atlantic, 32% in the Middle Atlantic, and 16% in the East North Central Census Divisions were linked with building water systems in healthcare and hotel settings; and were associated with buildings receiving drinking water from public water systems serving >10,000 people. Targeted evaluations and interventions may be useful to further determine the combination of factors, such as disinfectant residual type and drinking water system size that may lead to legionellosis outbreaks.