Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
1.
Int J Mol Sci ; 22(6)2021 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-33805752

RESUMO

Graphene coating on the cobalt-chromium alloy was optimized and successfully carried out by a cold-wall chemical vapor deposition (CW-CVD) method. A uniform layer of graphene for a large area of the Co-Cr alloy (discs of 10 mm diameter) was confirmed by Raman mapping coated area and analyzing specific G and 2D bands; in particular, the intensity ratio and the number of layers were calculated. The effect of the CW-CVD process on the microstructure and the morphology of the Co-Cr surface was investigated by scanning X-ray photoelectron microscope (SPEM), atomic force microscopy (AFM), scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). Nanoindentation and scratch tests were performed to determine mechanical properties of Co-Cr disks. The results of microbiological tests indicate that the studied Co-Cr alloys covered with a graphene layer did not show a pro-coagulant effect. The obtained results confirm the possibility of using the developed coating method in medical applications, in particular in the field of cardiovascular diseases.


Assuntos
Ligas de Cromo/química , Materiais Revestidos Biocompatíveis/química , Grafite/química , Animais , Fatores de Coagulação Sanguínea/metabolismo , Plaquetas/citologia , Plaquetas/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Ligas de Cromo/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Eritrócitos/efeitos dos fármacos , Humanos , Teste de Materiais/métodos , Camundongos , Células NIH 3T3 , Tempo de Tromboplastina Parcial , Ativação Plaquetária/efeitos dos fármacos , Cultura Primária de Células , Propriedades de Superfície , Volatilização
2.
PLoS One ; 16(2): e0246866, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33566856

RESUMO

INTRODUCTION: Implant material is a more important factor for periprosthetic tibial bone resorption than implant design after total knee arthroplasty (TKA). The virtual perturbation study was planned to perform using single case of proximal tibia model. We determined whether the implant materials' stiffness affects the degree of periprosthetic tibial bone resorption, and whether the effect of material change with the same implant design differed according to the proximal tibial plateau areas. MATERIALS AND METHODS: This three-dimensional finite element analysis included two cobalt-chromium (CoCr) and two titanium (Ti) tibial implants with different designs. They were implanted into the proximal tibial model reconstructed using extracted images from computed tomography. The degree of bone resorption or formation was measured using the strain energy density after applying axial load. The same analysis was performed after exchanging the materials while maintaining the design of each implant. RESULTS: The degree of periprosthetic tibial bone resorption was not determined by the type of implant materials alone. When the implant materials were changed from Ti to CoCr, the bone resorption in the medial compartment increased and vice versa. The effect of material composition's change on anterior and posterior areas varied accordingly. CONCLUSIONS: Although the degree of bone resorption was associated with implant materials, it differed depending on the design of each implant. The effect on the degree of bone resorption according to the materials after TKA should be evaluated while concomitantly considering design.


Assuntos
Reabsorção Óssea , Interface Osso-Implante/patologia , Próteses e Implantes , Desenho de Prótese , Tíbia , Reabsorção Óssea/metabolismo , Reabsorção Óssea/patologia , Reabsorção Óssea/prevenção & controle , Ligas de Cromo/farmacologia , Análise de Elementos Finitos , Humanos , Tíbia/metabolismo , Tíbia/fisiologia , Titânio/farmacologia
3.
J Biomed Mater Res A ; 109(1): 31-41, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32418271

RESUMO

Photofunctionalization of implant materials with ultraviolet (UV) radiation have been subject of study in the last two decades, and previous research on CoCrMo discs have showed good results in terms of bioactivity and the findings of apatite-like crystals in vitro. In the current study, CoCrMo domes were photofunctionalized with UV radiation of 254 nm on their internal faces during 24 hr; they were implanted in rabbit tibia and remained for 3, 4, and 6 weeks. The potential to induce bone formation beneath the dome-shaped membranes was evaluated through morphometric, histologic, and density measurements; and the results were compared with those obtained under control untreated domes. Higher density values were observed for irradiated domes at 3 weeks, whereas higher volumes were obtained under photofunctionalized domes for longer periods (4 and 6 weeks). Histologically, woven bone was formed by endochondral ossification in all cases; differences in the architecture and size of the trabeculae and in the number of osteoblasts were noted between irradiated and non-irradiated samples. The UV radiation of 254 nm generated a larger bone volume fraction compared to that found in the absence of UVC radiation and induced an increase of density in the early stages of healing, leading to a better initial bone quality and improved osseointegration.


Assuntos
Regeneração Óssea/efeitos dos fármacos , Ligas de Cromo/farmacologia , Ligas de Cromo/efeitos da radiação , Engenharia Tecidual/métodos , Animais , Interface Osso-Implante , Condrócitos/efeitos dos fármacos , Masculino , Membranas Artificiais , Osseointegração , Osteoblastos/efeitos dos fármacos , Osteogênese/efeitos dos fármacos , Coelhos , Tíbia/efeitos dos fármacos , Tíbia/crescimento & desenvolvimento , Raios Ultravioleta
4.
Coron Artery Dis ; 32(5): 391-396, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-33060529

RESUMO

OBJECTIVES: Recent improvements in coronary stent design have focussed on thinner struts, different alloys and architecture, more biocompatible polymers, and shorter drug absorption times. This study evaluates safety and efficacy of a newer generation thin-strut cobalt chromium sirolimus-eluting coronary stent (SES, Ultimaster) in comparison with a second-generation thicker strut stainless steel biolimus-eluting stent (BES, Nobori) in percutaneous coronary intervention (PCI) practice. METHODS: A propensity score analysis was performed to adjust for differences in baseline characteristics of 8137 SES patients and 2738 BES patients of two PCI registries (e-Ultimaster and NOBORI 2). An independent clinical event committee adjudicated all endpoint-related adverse events. RESULTS: The use of SES, as compared with BES was associated with a significantly lower rate of myocardial infarction (MI) (1.2% vs 2.2%; P = 0.0006) and target vessel-related MI (1.1% vs 1.8%; P = 0.002) at 1 year. One-year composite endpoints of all predefined endpoints were lower in patients undergoing SES implantation (target lesion failure: 3.2% vs 4.1%; P = 0.03, target vessel failure: 3.7% vs 5.0%; P = 0.003, patient-oriented composite endpoint 5.7% vs 6.8%; P = 0.03). No significant differences between SES and BES were observed in all-cause death (2.0% vs 1.6%; P = 0.19), cardiac death (1.2% vs 1.2%; P = 0.76) or stent thrombosis (0.6% vs 0.8%; P = 0.43). CONCLUSIONS: These findings suggest an improved clinical safety and efficacy of a newer generation thin-strut SES as compared with a second-generation thicker strut BES.


Assuntos
Ligas de Cromo/farmacologia , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Complicações Pós-Operatórias , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Idoso , Materiais Biocompatíveis/farmacologia , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Stents Farmacológicos/efeitos adversos , Stents Farmacológicos/classificação , Análise de Falha de Equipamento , Feminino , Humanos , Imunossupressores/farmacologia , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Sistema de Registros/estatística & dados numéricos , Análise de Sobrevida
5.
J Interv Cardiol ; 2020: 6340716, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33380923

RESUMO

AIMS: The goal of this study was to evaluate the performance of the InspironTM coronary stent (Scitech Medical™, Goiás, Brazil). The InspironTM sirolimus-eluting stent uses an ultrathin L-605 cobalt-chromium alloy with a 75 µm strut thickness platform coated with an abluminal biodegradable polymer. The polymer is eliminated from the body through the tricarboxylic acid cycle in 6-9 months, releasing 80% of the drug within 30 days after its deployment. METHODS: It was a prospective, single-center registry. To represent clinical practice, all patients undergoing percutaneous coronary intervention were included in this registry. There were no exclusion criteria. Clinical follow-ups were performed at twelve months. The endpoints were the occurrence of all-cause death, definite stent thrombosis, and new revascularization. RESULTS: Between November 2017 and May 2019, 790 patients were included (1067 lesions). The mean age was 60.42 ± 14.94 years, and 74.7% presented with acute coronary syndrome. Diabetes mellitus was present in 43.9% of patients, and previous myocardial infarction and previous percutaneous coronary intervention were present in 17.9% and 11.3%, respectively. Angiographic success was achieved in 99.1%. The incidence of all-cause death was 11.5% (6.2% in-hospital and 5.3% in the follow-up) and definitive stent thrombosis was 0.2%. New revascularization was performed in only 5.8% (target lesion revascularization: 2.2%; progression of disease in another lesion: 3.6%). Based on the multivariate regression analysis, only chronic renal failure was an independent predictor of adverse events (OR: 3.3; 95% CI: 1.22-8.92). CONCLUSION: The result of this single-center registry demonstrates the safety and excellent performance of the InspironTM stent in daily clinical practice with a low rate of adverse cardiac events.


Assuntos
Síndrome Coronariana Aguda , Plásticos Biodegradáveis/farmacologia , Ligas de Cromo/farmacologia , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea , Sirolimo/farmacologia , Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/cirurgia , Brasil/epidemiologia , Materiais Revestidos Biocompatíveis/farmacologia , Reestenose Coronária/epidemiologia , Reestenose Coronária/etiologia , Reestenose Coronária/cirurgia , Feminino , Humanos , Imunossupressores/farmacologia , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros/estatística & dados numéricos , Reoperação/estatística & dados numéricos
6.
Mater Sci Eng C Mater Biol Appl ; 109: 110522, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32228976

RESUMO

Electrochemically reduced graphene oxide (ErGO) films on a biomedical grade CoCr alloy have been generated and characterized in order to study their possible application for use on joint prostheses. The electrodeposition process was performed by cyclic voltammetry. The characterization of the ErGO films on CoCr alloys by XPS revealed sp2 bonding and the presence of CO and CO residual groups in the graphene network. Biocompatibility studies were performed with mouse macrophages J774A.1 cell cultures measured by the ratio between lactate dehydrogenase and mitochondrial activities. An enhancement in the biocompatibility of the CoCr with the ErGO films was obtained, a result that became more evident as exposure time increased. Macrophages on the CoCr with the ErGO were well-distributed and conserved the characteristic cell shape. In addition, vimentin expression was unaltered in comparison with the control, results that indicated an improvement in the CoCr biocompatibility with the ErGO on the material surface. The in vivo response of graphene and graphene oxide was assessed by intraperitoneal injection in wistar rats. Red blood cells are one of the primary interaction sites so hemocompatibility tests were carried out. Rats inoculated with graphene and graphene oxide showed red blood cells of smaller size with a high content in hemoglobin.


Assuntos
Ligas de Cromo , Materiais Revestidos Biocompatíveis , Técnicas Eletroquímicas , Grafite , Macrófagos/metabolismo , Teste de Materiais , Animais , Ligas de Cromo/química , Ligas de Cromo/farmacologia , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Grafite/química , Grafite/farmacologia , Masculino , Camundongos , Oxirredução , Ratos , Ratos Wistar
7.
Mater Sci Eng C Mater Biol Appl ; 106: 110156, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31753375

RESUMO

The silver contained coatings on cast Cobalt Chrome (CoCr) alloys were prepared by vacuum plasma spraying technique. The Scanning Electron Microscopy (SEM), X-ray photoelectron spectroscopy (XPS), X-ray Diffraction (XRD), energy dispersive spectrometry (EDS), properties of corrosion resistance, wear resistance and effect of vitro antibacterial on the surface of silver contained coating were investigated. The cytotoxicity of the coatings was performed with L-929 fibroblasts by MTT assay. SEM showed that the surfaces of the coatings were dense, smooth, no obvious cracks except only a few pores. XRD analysis indicated that the contents of the surface were mainly Ag and Cr except a small amount of Ag2O, Cr2O3. EDS analysis indicated that the distributions of Cr and Ag were uniform without any large-scale clustering. The wear resistance of silver coatings is similar to that of CoCr alloys, and the corrosion resistance is slightly better than that of CoCr alloys. The Ag coating had no significant effect on the proliferation of L929 cells. The antibacterial results indicated that the number of S. mutans and C. albicans were significantly reduced on the surface of silver contained coating than that of CoCr alloys. All the results indicated that the silver contained coatings can be achieved by vacuum plasma spraying technique with good surface characteristic and antibacterial properties and have promising applications in biomedical area.


Assuntos
Ligas de Cromo/química , Gases em Plasma/química , Prata/química , Animais , Candida albicans/efeitos dos fármacos , Pontos de Checagem do Ciclo Celular/efeitos dos fármacos , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Ligas de Cromo/farmacologia , Corrosão , Camundongos , Resistência ao Cisalhamento , Staphylococcus/efeitos dos fármacos , Propriedades de Superfície , Vácuo
8.
Biomed Res Int ; 2019: 3649838, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31781613

RESUMO

Metal wear debris and released ions (CoCrMo), which are widely generated in metal-on-metal bearings of hip implants, are also found in patients with metal-on-polyethylene bearings due to the mechanically assisted crevice corrosion of modular taper junctions, including head-neck and neck-stem taper interfaces. The resulting adverse reactions to metal debris and metal ions frequently lead to early arthroplasty revision surgery. National guidelines have since been published where the blood metal ion concentration of patients must consistently be monitored after joint replacement to prevent serious complications from developing after surgery. However, to date, the effect of metal particles and metal ions on local biological reactions is complex and still not understood in detail; the present study sought to elucidate the complex mechanism of metal wear-associated inflammation reactions. The knee joints in 4 groups each consisting of 10 female BALB/c mice received injections with cobalt chrome ions, cobalt chrome particles, and ultra-high-molecular-weight polyethylene (UHMWPE) particles or PBS (control). Seven days after injection, the synovial microcirculation and knee joint diameter were assessed via intravital fluorescence microscopy followed by histological evaluation of the synovial layer. Enlarged knee diameter, enhanced leukocyte to endothelial cell interactions, and an increase in functional capillary density within cobalt chrome particle-treated animals were significantly greater than those in the other treatment groups. Subsequently, pseudotumor-like tissue formations were observed only in the synovial tissue layer of the cobalt chrome particle-treated animals. Therefore, these findings strongly suggest that the cobalt chrome particles and not metal ions are the cause for in vivo postsurgery implantation inflammation.


Assuntos
Artroplastia de Quadril/efeitos adversos , Ligas de Cromo/efeitos adversos , Prótese de Quadril/efeitos adversos , Metais/efeitos adversos , Animais , Ligas de Cromo/farmacologia , Corrosão , Modelos Animais de Doenças , Humanos , Inflamação/sangue , Inflamação/induzido quimicamente , Articulação do Joelho/cirurgia , Metais/uso terapêutico , Camundongos , Polietileno/farmacologia , Falha de Prótese/efeitos adversos , Reoperação , Líquido Sinovial/efeitos dos fármacos
9.
Biomaterials ; 217: 119306, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31271854

RESUMO

Monocytes are active at the crossroads between inflammation and coagulation processes since they can secrete pro-inflammatory cytokines and express tissue factor (TF), a major initiator of coagulation. Cobalt-chrome (CoCr), a metal alloy, used as a biomaterial for vascular stents, has been shown to be potentially pro-thrombotic and pro-inflammatory. Research work with a polymer from a family of degradable-polar hydrophobic ionic polyurethanes (D-PHI), called HHHI, has been shown to exhibit anti-inflammatory responses from human monocytes. We have generated multifunctional polyurethane thin films (MPTF) based on the HHHI chemistry, as a thin coating for CoCr and have evaluated the reactivity of blood with MPTF-coated CoCr. The results showed that the coating of CoCr with MPTF derived from HHHI prevents thrombin generation, reduces coagulation activation, and suppresses fibrin formation in whole blood. Activation of monocytes was also suppressed at the surface of MPTF-coated CoCr and specifically the decrease in thrombin generation was accompanied by a significant decrease in TF and pro-inflammatory cytokine levels. Mass spectroscopy of the adsorbed proteins showed lower levels of fibrinogen, fibronectin and complement C3, C4, and C8 when compared to CoCr. We can conclude that MPTFs reduce the pro-thrombotic and pro-inflammatory phenotype of monocytes and macrophages on CoCr, and prevent clotting in whole blood.


Assuntos
Ligas de Cromo/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Interações Hidrofóbicas e Hidrofílicas , Monócitos/patologia , Poliuretanos/farmacologia , Trombose/patologia , Forma Celular/efeitos dos fármacos , Fibrina/metabolismo , Humanos , Inflamação/patologia , Mediadores da Inflamação/farmacologia , Íons , Macrófagos/efeitos dos fármacos , Macrófagos/ultraestrutura , Monócitos/efeitos dos fármacos , Análise de Componente Principal , Propriedades de Superfície , Trombina/metabolismo , Tromboplastina/metabolismo , Fator de Necrose Tumoral alfa/farmacologia
10.
Eur Cell Mater ; 37: 1-15, 2019 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-30614513

RESUMO

In the context of shoulder surgical replacement, a new generation of spherical interposition implants has been developed, with the implant being a mobile spacer rubbing against the glenoid cartilage and humeral bone cavity. The aim of the present study was to compare pyrocarbon (PyC) versus cobalt-chromium (CoCr) implants, regarding preservation and regeneration of the surrounding tissues. The effect of the biomaterials on chondrocytes was analysed in vitro. Murine primary chondrocytes were grown on discs made of PyC or CoCr using two culture media to mimic either cartilage-like or bone-like conditions (CLC or BLC). Chondrocytes did grow on PyC and CoCr without alteration in cell viability or manifestation of cytotoxicity. The tissue-like cell membranes grown under BLC were examined for the chondrocyte's ability to mineralise (by alizarin red matrix staining, calcium deposit and alkaline phosphatase activity) and for their mechanical properties (by rheological tests). For the chondrocytes grown under CLC and BLC, extracellular matrix components were analysed by histological staining and immunolabelling. Under CLC, PyC promoted type II collagen expression in chondrocytes, suggesting that they may generate a more cartilage-like matrix than samples grown on both CoCr and plastic control. In BLC, the tissue-like cell membranes grown on PyC were more mineralised and homogenous. The mechanical results corroborated the biological data, since the elastic modulus of the tissue-like cell membranes developed on the PyC surface was higher, indicating more stiffness. Overall, the results suggested that PyC might be a suitable biomaterial for spherical interposition implants.


Assuntos
Carbono/farmacologia , Condrócitos/citologia , Ligas de Cromo/farmacologia , Próteses e Implantes , Animais , Materiais Biocompatíveis/farmacologia , Osso e Ossos/citologia , Calcificação Fisiológica/efeitos dos fármacos , Cartilagem/citologia , Membrana Celular/efeitos dos fármacos , Membrana Celular/metabolismo , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Condrócitos/efeitos dos fármacos , Condrócitos/metabolismo , Matriz Extracelular/efeitos dos fármacos , Matriz Extracelular/metabolismo , Camundongos , Reprodutibilidade dos Testes , Reologia
11.
J Biomed Mater Res B Appl Biomater ; 106(2): 632-638, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28276193

RESUMO

Recently the use of dissimilar metals in spine instrumentation has increased, especially in the case of adult deformities, where rods made from Cobalt Chrome alloys (CoCr) are used with Titanium (Ti) screws. The use of dissimilar metals increases the risk of galvanic corrosion and patients have required revision spine surgery due to severe metallosis that may have been caused by corrosion. We aimed to assess the presence of corrosion in spine implant retrievals from constructs with two types of material combinations: similar (Ti/Ti) and dissimilar (CoCr/Ti). First, we devised a grading score for corrosion of the rod-fixture junctions. Then, we applied this score to a collection of retrieved spine implants. Our proposed corrosion grading score was proven reliable (kappa > 0.7). We found no significant difference in the scores between 4 CoCr and 11 Ti rods (p = 0.0642). There was no indication that time of implantation had an effect on the corrosion score (p = 0.9361). We recommend surgeons avoid using implants designs with dissimilar metals to reduce the risk of corrosion whilst a larger scale study of retrieved spine implants is conducted. Future studies can now use our scoring system for spine implant corrosion. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 632-638, 2018.


Assuntos
Ligas de Cromo/farmacologia , Remoção de Dispositivo , Próteses e Implantes/efeitos adversos , Coluna Vertebral/efeitos dos fármacos , Titânio/farmacologia , Adulto , Estudos de Coortes , Corrosão , Feminino , Humanos , Masculino , Parafusos Pediculares , Fatores de Risco , Coluna Vertebral/cirurgia , Fatores de Tempo
12.
J Biomed Mater Res B Appl Biomater ; 105(8): 2326-2332, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27504737

RESUMO

BACKGROUND: Osteolysis which leads to aseptic loosening of implants is a fundamental problem in joint replacement surgery (arthroplasty) and the leading cause for implant failure and revision surgery. Metal (CoCr) particles separated from implants by wear cause osteolysis and the failure of orthopedic implants, but the molecular mechanism is not clear. The chemokine receptor CXCR4 has been shown to play a pivotal role in periprosthetic osteolysis. The aim of this study was to determine which signal transduction pathway (PLC-DAG-PKC or MAPK/ERK) induces CXCR4 expression in osteoblast-like cells (MG63) cells. METHODS: MG63 and Jurkat cells were stimulated with different amounts of particles (107 , 106 , and 105 ) for different time periods (30 min to 24 h), in the presence and absence of specific inhibitors (chelerythrine for the PLC-DAG-PKC pathway and PD98059 for the MAPK/ERK pathway). The expression of CXCR4-specific mRNA was determined by real-time polymerase chain reaction (PCR), and the PKC activity was measured by Western Blot using an antibody specific for PKC-related phosphorylation. RESULTS: Real-time PCR data showed that CXCR4 mRNA expression in MG63 cells induced by CoCr particles was significantly diminished by the PKC-specific inhibitor chelerythrine. This effect was not observed with the MAPK/ERK inhibitor PD98059. The involvement of PKC was also confirmed by an intensified phosphorylation pattern after stimulation with CoCr particles. In Jurkat cells, none of the inhibitors exhibited any effect. CONCLUSION: The induction of CXCR4-specific mRNA expression in MG63 cells after stimulation with CoCr particles is regulated by the PLC-DAG-PKC pathway and not by the MAPK/ERK pathway. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2326-2332, 2017.


Assuntos
Ligas de Cromo/efeitos adversos , Regulação da Expressão Gênica/efeitos dos fármacos , Sistema de Sinalização das MAP Quinases/efeitos dos fármacos , Próteses Articulares Metal-Metal/efeitos adversos , Osteólise , Receptores CXCR4/biossíntese , Artroplastia/efeitos adversos , Interface Osso-Implante/patologia , Linhagem Celular , Ligas de Cromo/farmacologia , Humanos , Células Jurkat , Osteoblastos/patologia , Osteólise/induzido quimicamente , Osteólise/metabolismo , Osteólise/patologia
13.
Colloids Surf B Biointerfaces ; 145: 176-184, 2016 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-27182652

RESUMO

Under tribological contact, the subsurface microstructure of CoCrMo alloys for artificial joint implants can be changed and affect the life and safety of such devices. As one of the most important and abundant components in the synovial fluid, proteins play a key role in affecting the bio-tribocorrosion behaviors of metal implants. The effect of proteins on the subsurface microstructure evolution of a CoCrMo alloy was investigated using a transmission electron microscope (TEM) in this study. The result shows that proteins have two main effects on the subsurface's evolution: forming a multilayered structure and causing severer subsurface deformation. The tribo-film can protect the passive film from scrapping, and then the passive film can reduce or even suppress the stacking fault annihilation by blocking the access to the metal surface. It leads to the stacking fault being diffused towards the deeper area and a strain accumulation in the subsurface, before inducing a severer deformation. On the other hand, the effect of proteins results in the location changing from the top surface to be underneath the top surface, where the maximum frictional shear stress occurs. This can cause a deeper deformation.


Assuntos
Ligas de Cromo/farmacologia , Soroalbumina Bovina/farmacologia , Animais , Bovinos , Corrosão , Espectroscopia Fotoeletrônica , Espectrometria por Raios X , Propriedades de Superfície , Fatores de Tempo
14.
J Biomed Mater Res A ; 103(11): 3564-71, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25966675

RESUMO

This study compared the particulate and ion forms of a cobalt-chrome (Co-Cr) alloy on the differentiation/activation of preosteoblasts. Mouse preosteoblasts (MC3T3-E1) were cultured in an osteoblast-induction medium in the presence of particulate and ion forms of a Co-Cr alloy, followed by cell proliferation and cytotoxicity evaluations. The maturation and function of osteoblasts were assessed by alkaline phosphatase (ALP) assay and related gene expressions. Both particulate and ion forms of the metals significantly reduced the proliferation of MC3T3-E1 cells in a dose-dependent manner. Similarly, cells challenged with high concentrations of particles and ions exhibited a marked cytotoxic effect and diminished expression of ALP. Real-time (RT) polymerase chain reaction (PCR) data have suggested that cells with Co-Cr particles dramatically promoted over-expression of monocyte chemo-attractant protein-1 (MCP-1), tumor necrosis factor-α (TNF-α), and interleukin-6 (IL-6), whereas Co(2+) ions treatment predominately up-regulated expressions of receptor activator of nuclear factor kappa-B ligand (RANKL), nuclear factor of activated T-cells cytoplasmic 1 (NFATc1), and down-regulated expression of osteoprotegerin (OPG) and Osterix (Osx). Overall, this study provides evidence that both Co-Cr alloy particles and metal ions interfered with the MC3T3-E1 cells for their growth, maturation, and functions. Further, Co-Cr particles exhibited stronger effects on inflammatory mediators, while metal ions showed more influence on inhibition of osteoblast differentiation and promotion of osteoclastogenesis.


Assuntos
Ligas de Cromo/farmacologia , Osteoblastos/citologia , Material Particulado/farmacologia , Fosfatase Alcalina/metabolismo , Animais , Morte Celular/efeitos dos fármacos , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Forma Celular/efeitos dos fármacos , Perfilação da Expressão Gênica , Íons , L-Lactato Desidrogenase/metabolismo , Camundongos , Osteoblastos/efeitos dos fármacos , Osteoblastos/enzimologia , Reação em Cadeia da Polimerase em Tempo Real
15.
Colloids Surf B Biointerfaces ; 127: 22-32, 2015 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-25637794

RESUMO

To improve cardiovascular implant success, metal-based stents are designated to modulate endothelial cells adhesion and migration in order to prevent restenosis and late thrombosis diseases. Biomimetic coatings with extra-cellular matrix adhesive biomolecules onto stents surfaces are a strategy to recover a healthy endothelium. However, the appropriate bioactive sequences to selective promote growth of endothelium and the biomolecules surface immobilization strategy remains to be elucidated. In this study, biofunctionalization of cobalt chromium, CoCr, alloy surfaces with elastin-like recombinamers, ELR, genetically modified with an REDV sequence, was performed to enhance metal surfaces endothelialization. Moreover, physical adsorption and covalent bonding were used as biomolecules binding strategies onto CoCr alloy. Surfaces were activated with plasma and etched with sodium hydroxide previous to silanization with 3-chloropropyltriethoxysilane and functionalized with the ELR. CoCr alloy surfaces were successfully biofunctionalized and the use of an ELR with an REDV sequence, allows conferring bioactivity to the biomaterials surface, demonstrating a higher cell adhesion and spreading of HUVEC cells on the different CoCr surfaces. This effect is emphasized as increases the amount of immobilized biomolecules and directly related to the immobilization technique, covalent bonding, and the increase of surface charge electronegativity. Our strategy of REDV elastin-like recombinamers immobilization onto CoCr alloy surfaces via covalent bonding through organosilanes provides a bioactive surface that promotes endothelial cell adhesion and spreading.


Assuntos
Sistema Cardiovascular/efeitos dos fármacos , Ligas de Cromo/farmacologia , Elastina/química , Elastina/farmacologia , Endotélio/efeitos dos fármacos , Adsorção , Sequência de Aminoácidos , Adesão Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Fluoresceína-5-Isotiocianato/metabolismo , Fluorescência , Células Endoteliais da Veia Umbilical Humana/citologia , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos , Humanos , Ponto Isoelétrico , Microscopia de Força Atômica , Oligopeptídeos/farmacologia , Espectroscopia Fotoeletrônica , Eletricidade Estática , Termodinâmica , Molhabilidade
16.
Lasers Med Sci ; 30(2): 909-14, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24326743

RESUMO

The effects of voltage and laser beam (spot) diameter on the penetration depth during laser beam welding in a representative nickel-chromium (Ni-Cr) dental alloy were the subject of this study. The cast alloy specimens were butted against each other and laser welded at their interface using various voltages (160-390 V) and spot diameters (0.2-1.8 mm) and a constant pulse duration of 10 ms. After welding, the laser beam penetration depths in the alloy were measured. The results were plotted and were statistically analyzed with a two-way ANOVA, employing voltage and spot diameter as the discriminating variables and using Holm-Sidak post hoc method (a = 0.05). The maximum penetration depth was 4.7 mm. The penetration depth increased as the spot diameter decreased at a fixed voltage and increased as the voltage increased at a fixed spot diameter. Varying the parameters of voltage and laser spot diameter significantly affected the depth of penetration of the dental cast Ni-Cr alloy. The penetration depth of laser-welded Ni-Cr dental alloys can be accurately adjusted based on the aforementioned results, leading to successfully joined/repaired dental restorations, saving manufacturing time, reducing final cost, and enhancing the longevity of dental prostheses.


Assuntos
Ligas de Cromo/farmacologia , Ligas Dentárias/farmacologia , Técnica de Fundição Odontológica , Lasers de Estado Sólido , Soldagem em Odontologia , Soldagem
17.
J Biomed Mater Res B Appl Biomater ; 103(3): 629-40, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24964763

RESUMO

CoCr alloys, in particular MP35N and L605, are extensively used in biomedical implants, for example for coronary stents. In practice, these alloys present a moderately hydrophobic surface which leads to significant platelet adhesion and consequently to risk of early thrombosis or in-stent restenosis. Surface modification of biomedical implants is known to alter their biological performances. In this study we focused on the alteration of in vitro biological responses of human cells contacting CoCr surfaces with engineered oxide layers. XPS analysis was performed to determine the composition of the oxide layer of differently treated CoCr while the bulk properties were not modified. An extensive characterization of the surfaces was performed looking at surface roughness, wettability and charge. After static exposure to blood, strongly reduced platelet and increased polymorphonuclear neutrophil adhesion were observed on treated versus untreated surfaces. Comparisons of treated and untreated samples provide evidence for wettability being an important player for platelet adhesion, although multiple factors including surface oxide chemistry and charge might control polymorphonuclear neutrophil adhesion. The differently treated surfaces were shown to be equally suitable for endothelial cell proliferation. We herein present a novel approach to steer biological properties of CoCr alloys. By adjusting their oxide layer composition, substrates were generated which are suitable for endothelial cell growth and at the same time show an altered (reduced) blood contact activation. Such treatments are expected to lead to stents of highly reproducible quality with minimal thrombogenicity and in-stent restenosis, while maintaining rapid re-endothelialization after coronary angioplasty.


Assuntos
Ligas/farmacologia , Coagulação Sanguínea/efeitos dos fármacos , Ligas de Cromo/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Ativação do Complemento/efeitos dos fármacos , Endotélio Vascular/efeitos dos fármacos , Óxidos/farmacologia , Stents , Sangue , Células Sanguíneas/citologia , Células Sanguíneas/efeitos dos fármacos , Adesão Celular/efeitos dos fármacos , Contagem de Células , Células Cultivadas , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/ultraestrutura , Endotélio Vascular/metabolismo , Humanos , Teste de Materiais , Revascularização Miocárdica/instrumentação , Neutrófilos/citologia , Neutrófilos/efeitos dos fármacos , Oxirredução , Oxigênio/farmacologia , Reprodutibilidade dos Testes , Cloreto de Sódio/farmacologia , Eletricidade Estática , Propriedades de Superfície , Trombose/prevenção & controle , Molhabilidade
18.
Catheter Cardiovasc Interv ; 86(1): E11-8, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25534499

RESUMO

BACKGROUND: To date, it remains unknown whether different types of new-generation drug-eluting stents have a differential impact on long-term outcomes in diabetic patients. METHODS AND RESULTS: In this historical cohort study (two Italian centers), we analyzed 400 diabetic patients with 553 coronary lesions treated with new-generation CoCr zotarolimus-eluting stents (R-ZES: 136 patients, 196 lesions) or everolimus-eluting stents (EES: 264 patients, 357 lesions) between October 2006 and August 2012. Primary endpoint was the occurrence of major adverse cardiac events (MACE) over a 2-year follow-up period. MACE was defined as all-cause mortality, any myocardial infarction (MI) and/or target lesion revascularization (TLR). Multivessel revascularization, intervention for restenotic lesion and use of intravascular ultrasound were significantly higher in the R-ZES group, whereas small stent (≤2.5 mm) deployment was significantly higher in the EES group. At 2-year follow-up, there was no significant difference in occurrence of MACE (R-ZES vs EES: 22.8% vs 18.9%, P = 0.39). Similarly, no significant differences were observed in the composite endpoint of all-cause mortality/MI (10.0% vs 10.3%, P = 0.86) or TLR (12.4% vs 7.4%, P = 0.11). Adjustment for confounders and baseline propensity-score matching did not alter the aforementioned associations. CONCLUSION: After 2 years of follow up similar outcomes (MACE, all-cause mortality/MI, TLR) were observed in real-world diabetic patients, including those with complex lesions and patient characteristics, treated with R-ZES and EES.


Assuntos
Ligas de Cromo/farmacologia , Doença da Artéria Coronariana/cirurgia , Diabetes Mellitus , Stents Farmacológicos , Everolimo/farmacologia , Intervenção Coronária Percutânea/métodos , Sirolimo/análogos & derivados , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Imunossupressores/farmacologia , Incidência , Japão/epidemiologia , Masculino , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Estudos Retrospectivos , Sirolimo/farmacologia , Fatores de Tempo , Resultado do Tratamento
19.
J Colloid Interface Sci ; 417: 410-9, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-24407704

RESUMO

HYPOTHESIS: Anatase-modified titanium (Ti) substrates have been found to possess antibacterial properties in the absence of ultraviolet irradiation, but the mechanism is not known. We hypothesize that this is due to the bactericidal effects of reactive oxygen species (ROS) generated by the surface anatase. EXPERIMENTS: Alkali and heat treatment was used to form anatase on Ti surface. The generation of ROS, and the behavior of bacteria and osteoblasts on the anatase-modified Ti were investigated. Cobalt-chrome (Co-Cr) alloys and stainless steel (SS) were similarly treated with alkali and heat, and their surface properties and effects on bacteria and osteoblasts were compared with the results obtained with Ti. FINDINGS: The anatase-functionalized Ti substrates demonstrated significant bactericidal effects and promoted apoptosis in osteoblasts, likely a result of ROS generated by the anatase. The alkali and heat-treated Co-Cr and SS substrates also reduced bacterial adhesion but were not bactericidal. This effect is likely due to an increase in hydrophilicity of the surfaces, and no significant ROS were generated by the alkali and heat-treated Co-Cr and SS substrates. The treated Co-Cr and SS substrates did not induce significant apoptosis in osteoblasts, and thus with these properties, they may be promising for orthopedic applications.


Assuntos
Antibacterianos/química , Materiais Biocompatíveis/química , Ligas de Cromo/química , Aço Inoxidável/química , Titânio/química , Álcalis/química , Antibacterianos/farmacologia , Apoptose/efeitos dos fármacos , Aderência Bacteriana/efeitos dos fármacos , Materiais Biocompatíveis/farmacologia , Ligas de Cromo/farmacologia , Escherichia coli/efeitos dos fármacos , Escherichia coli/crescimento & desenvolvimento , Temperatura Alta , Humanos , Osteoblastos/citologia , Osteoblastos/efeitos dos fármacos , Espécies Reativas de Oxigênio/química , Aço Inoxidável/farmacologia , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/crescimento & desenvolvimento , Propriedades de Superfície , Titânio/toxicidade
20.
J Biomed Mater Res A ; 101(10): 2817-25, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24039045

RESUMO

This study investigates the roles of orthopedic biomaterial particles [Ti-alloy, poly(methyl methacrylate) (PMMA), ultrahigh-molecular-weight polyethylene (UHMWPE), Co-Cr alloy] on the differentiation and functions of bone marrow stromal cells (BMSCs). Cells were isolated from femurs of BALB/c mice and cultured in complete osteoblast-induction medium in presence of micron-sized biomaterial particles at various doses. 3-(4,5)-Dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide assay and lactate dehydrogenase assay were performed for cell proliferation and cytotoxicity. Differentiation and function of osteoblasts were evaluated by alkaline phosphatase (ALP), osteocalcin, RANKL, OSX, and Runx2 expressions. Murine interleukin-1 (IL-1), IL-6, and tumor necrosis factor-α in culture media were determined by enzyme-linked immunosorbent assay. Challenge with low doses of Ti, UHMWPE, or Co-Cr particles markedly promoted the bone marrow cell proliferation while high dose of Co-Cr significantly inhibited cell growth (p < 0.05). Cells challenged with low dose of PMMA or UHMWPE particles (0.63 mg/mL) exhibited strong ALP activity, whereas Ti and Co-Cr groups showed minimal effects (p < 0.05). UHMWPE and Ti particles also promoted higher expression of proinflammatory cytokines. Real-time polymerase chain reaction data suggested that cells treated with low dose (0.5 mg/mL) particles resulted in distinctly diminished RANKL expression compared to those exposed to high concentrated (3 mg/mL) particles. In conclusion, various types of wear debris particles behaved differently in the differentiation, maturation, and functions of osteogenic cells; and the particulate debris-interacted BMSCs may play an important role in the pathogenesis and process of the debris-associated aseptic prosthetic loosening.


Assuntos
Células da Medula Óssea/citologia , Diferenciação Celular/efeitos dos fármacos , Ligas de Cromo/farmacologia , Polietilenos/farmacologia , Polimetil Metacrilato/farmacologia , Titânio/farmacologia , Fosfatase Alcalina/metabolismo , Animais , Células da Medula Óssea/efeitos dos fármacos , Células da Medula Óssea/enzimologia , Morte Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Forma Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Meios de Cultivo Condicionados/química , Citocinas/metabolismo , Ensaio de Imunoadsorção Enzimática , Perfilação da Expressão Gênica , Imuno-Histoquímica , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Osteocalcina/metabolismo , Ligante RANK/metabolismo , Reação em Cadeia da Polimerase em Tempo Real , Células Estromais/citologia , Células Estromais/efeitos dos fármacos , Células Estromais/enzimologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA