Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.970
Filtrar
1.
Transl Vis Sci Technol ; 13(5): 2, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38696181

RESUMO

Purpose: Currently, no solution exists to restore natural eyelid kinematics for patients with complete eyelid paralysis due to loss of function of both the levator palpebrae superioris and orbicularis oculi. These rare cases are prone to complications of chronic exposure keratopathy which may lead to corneal blindness. We hypothesized that magnetic force could be used to fully automate eyelid movement in these cases through the use of eyelid-attached magnets and a spectacle-mounted magnet driven by a programmable motor (motorized magnetic levator prosthesis [MMLP]). Methods: To test this hypothesis and establish proof of concept, we performed a finite element analysis (FEA) for a prototype MMLP to check the eyelid-opening force generated by the device and verified the results with experimental measurements in a volunteer with total bidirectional eyelid paralysis. The subject was then fitted with a prototype to check the performance of the device and its success. Results: With MMLP, eye opening was restored to near normal, and blinking was fully automated in close synchrony with the motor-driven polarity reversal, with full closure on the blink. The device was well tolerated, and the participant was pleased with the comfort and performance. Conclusions: FEA simulation results conformed to the experimentally observed trend, further supporting the proof of concept and design parameters. This is the first viable approach in human patients with proof of concept for complete reanimation of a bidirectionally paretic eyelid. Further study is warranted to refine the prototype and determine the feasibility and safety of prolonged use. Translational Relevance: This is first proof of concept for our device for total bidirectional eyelid paralysis.


Assuntos
Piscadela , Pálpebras , Estudo de Prova de Conceito , Humanos , Piscadela/fisiologia , Pálpebras/fisiopatologia , Doenças Palpebrais/fisiopatologia , Doenças Palpebrais/terapia , Músculos Oculomotores/fisiopatologia , Análise de Elementos Finitos , Fenômenos Biomecânicos , Próteses e Implantes , Desenho de Prótese , Imãs , Masculino
2.
Ophthalmic Plast Reconstr Surg ; 40(3): 336-339, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38738711

RESUMO

PURPOSE: To investigate the relationship between the kinematics of spontaneous blinks and the anterior area of the levator palpebrae superioris muscle in patients with Graves orbitopathy (GO). METHODS: This is a case-control study. The authors measured the margin reflex distance of the upper eyelid (margin reflex distance 1), the kinematics of spontaneous blinks, and the anterior area of levator palpebrae superioris muscle in CT coronal scans of patients with Graves upper eyelid retraction (GO) and a control group. The eye with the greatest margin reflex distance 1 was selected for analysis in each group. RESULTS: A total of 68 participants were included, with 36 in the GO group and 32 in the control group. In the GO group, the mean margin reflex distance 1 measured 6.5 mm, while in the control group, it was 3.9 mm. Almost all parameters related to the closing phase of spontaneous blinking activity, including amplitude, velocity, blinking rate, and interblink time, did not differ between the two groups. However, the effectiveness of the blink's amplitude (ratio of blink amplitude to margin reflex distance 1) and the main sequence (relationship between amplitude and velocity) were significantly reduced in the GO group compared with the control group. The area of the levator palpebrae superioris muscle was significantly larger in GO than in controls, with 71.4% of patients' muscles outside of the maximum range of the controls. CONCLUSIONS: In patients with GO, there is a reduction in blinking effectiveness, also known as blink lagophthalmos, which is a factor in the common occurrence of ocular surface symptoms. The increase in velocity with amplitude is also reduced in GO.


Assuntos
Piscadela , Pálpebras , Oftalmopatia de Graves , Músculos Oculomotores , Humanos , Piscadela/fisiologia , Feminino , Oftalmopatia de Graves/fisiopatologia , Oftalmopatia de Graves/complicações , Oftalmopatia de Graves/diagnóstico , Masculino , Pessoa de Meia-Idade , Músculos Oculomotores/fisiopatologia , Adulto , Estudos de Casos e Controles , Pálpebras/fisiopatologia , Doenças Palpebrais/fisiopatologia , Doenças Palpebrais/diagnóstico , Idoso , Tomografia Computadorizada por Raios X , Lagoftalmia
3.
Ophthalmic Plast Reconstr Surg ; 40(3): 346-351, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38738712

RESUMO

PURPOSE: Scar contracture of the eyelid following facial burns often has adverse consequences. Total cicatricial contracture often makes adjustment flap translation challenging to implement. Previously used upper and lower eyelid adhesion methods are ineffective for patients with severe cicatricial contracture, and ectropion can easily recur. This study aimed to retrospectively examine upper and lower eyelid adhesions using an orbicularis oculi muscle flap and verify its stability. METHODS: In patients with ectropion caused by severe scar contracture following head and face burns, we employed a tunnel orbicularis oculi muscle flap technique, which involved creating a tunnel between the skin and the tarsal plate of the eyelid, mobilizing the orbicularis oculi muscle, and rotating it into this tunnel to provide stable adhesion of the upper and lower eyelids. Full-thickness skin grafting was then performed. The eyelids were examined postoperatively to determine whether reoperation was necessary and to monitor for any potential complications. RESULTS: This study included 26 patients and 46 eyes. No accidental disconnection occurred after eyelid adhesion, which lasted for an average of 21.87 ± 10.08 months before the eyelid adhesion was cut open. No complications or adverse reactions occurred, and the adhesions did not break unexpectedly. CONCLUSIONS: Repairing eyelid ectropion with the tunnel orbicularis oculi muscle flap is a simple procedure that immediately creates tension against upper and lower eyelid contractures, providing long-term stable adhesion. This method avoids structural disorders, such as eyelid margin scarring, minimally influences surrounding tissues, and has few postoperative complications. It holds great value for repairing eyelid tissue defects and warrants further study.


Assuntos
Ectrópio , Pálpebras , Músculos Oculomotores , Transplante de Pele , Retalhos Cirúrgicos , Humanos , Ectrópio/cirurgia , Ectrópio/etiologia , Masculino , Feminino , Estudos Retrospectivos , Adulto , Transplante de Pele/métodos , Pessoa de Meia-Idade , Músculos Oculomotores/cirurgia , Músculos Oculomotores/fisiopatologia , Adulto Jovem , Pálpebras/cirurgia , Blefaroplastia/métodos , Adolescente , Criança , Aderências Teciduais/cirurgia , Aderências Teciduais/etiologia , Queimaduras Oculares/cirurgia , Queimaduras Oculares/fisiopatologia , Queimaduras Oculares/diagnóstico
4.
Optom Vis Sci ; 101(4): 204-210, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38684063

RESUMO

SIGNIFICANCE: A wearable optical apparatus that compensates for eye misalignment (strabismus) to correct for double vision (diplopia) is proposed. In contrast to prism lenses, commonly used to compensate for horizontal and/or vertical misalignment, the proposed approach is able to compensate for any combination of horizontal, vertical, and torsional misalignment. PURPOSE: If the action of the extraocular muscles is compromised (e.g., by nerve damage), a patient may lose their ability to maintain visual alignment, negatively affecting their binocular fusion and stereo depth perception capability. Torsional misalignment cannot be mitigated by standard Fresnel prism lenses. Surgical procedures intended to correct torsional misalignment may be unpredictable. A wearable device able to rectify visual alignment and restore stereo depth perception without surgical intervention could potentially be of great value to people with strabismus. METHODS: We propose a novel lightweight wearable optical device for visual alignment correction. The device comprises two mirrors and a Fresnel prism, arranged in such a way that together they rotationally shift the view seen by the affected eye horizontally, vertically, and torsionally. The extent of the alignment correction on each axis can be arbitrarily adjusted according to the patient's particular misalignment characteristics. RESULTS: The proposed approach was tested by computer simulation, and a prototype device was manufactured. The prototype device was tested by a strabismus patient exhibiting horizontal and torsional misalignment. In these tests, the device was found to function as intended, allowing the patient to enjoy binocular fusion and stereo depth perception while wearing the device for daily activities over a period of several months. CONCLUSIONS: The proposed device is effective in correcting arbitrary horizontal, vertical, and torsional misalignment of the eyes. The results of the initial testing performed are highly encouraging. Future study is warranted to formally assess the effectiveness of the device on multiple test patients.


Assuntos
Desenho de Equipamento , Músculos Oculomotores , Estrabismo , Visão Binocular , Dispositivos Eletrônicos Vestíveis , Humanos , Estrabismo/fisiopatologia , Estrabismo/cirurgia , Estrabismo/terapia , Visão Binocular/fisiologia , Músculos Oculomotores/fisiopatologia , Músculos Oculomotores/cirurgia , Percepção de Profundidade/fisiologia , Óculos , Movimentos Oculares/fisiologia
5.
Neurology ; 102(10): e209395, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38669629

RESUMO

BACKGROUND AND OBJECTIVES: We developed repetitive ocular vestibular-evoked myogenic potentials (roVEMP) as an electrophysiologic test that allows us to elicit the characteristic decrement of extraocular muscles in patients with ocular myasthenia gravis (OMG). Case-control studies demonstrated that roVEMP reliably differentiates patients with OMG from healthy controls. We now aimed to evaluate the diagnostic accuracy of roVEMP for OMG diagnosis in patients with ptosis and/or diplopia. METHODS: In this blinded prospective diagnostic accuracy trial, we compared roVEMP in 89 consecutive patients presenting with ptosis and/or diplopia suspicious of OMG with a multimodal diagnostic approach, including clinical examination, antibodies, edrophonium testing, repetitive nerve stimulation of accessory and facial nerves, and single-fiber EMG (SFEMG). We calculated the roVEMP decrement as the ratio between the mean of the first 2 responses compared with the mean of the sixth-ninth responses in the train and used cutoff of >9% (unilateral decrement) in a 30 Hz stimulation paradigm. RESULTS: Following a complete diagnostic work-up, 39 patients (44%) were diagnosed with ocular MG, while 50 patients (56%) had various other neuro-ophthalmologic conditions, but not MG (non-MG). roVEMP yielded 88.2% sensitivity, 30.2% specificity, 50% positive predictive value (PPV), and 76.5% negative predictive value (NPV). For comparison, SFEMG resulted in 75% sensitivity, 56% specificity, 55.1% PPV, and 75.7% NPV. All other diagnostic tests (except for the ice pack test) also yielded significantly higher positive results in patients with MG compared with non-MG. DISCUSSION: The study revealed a high sensitivity of 88.2% for roVEMP in OMG, but specificity and PPV were too low to allow for the OMG diagnosis as a single test. Thus, differentiating ocular MG from other neuro-ophthalmologic conditions remains challenging, and the highest diagnostic accuracy is still obtained by a multimodal approach. In this study, roVEMP can complement the diagnostic armamentarium for the diagnosis of MG. CLASSIFICATION OF EVIDENCE: This study provides Class I evidence that in patients with diplopia and ptosis, roVEMP alone does not accurately distinguish MG from non-MG disorders. TRIAL REGISTRATION INFORMATION: ClinicalTrials.gov: NCT03049956.


Assuntos
Blefaroptose , Diplopia , Miastenia Gravis , Potenciais Evocados Miogênicos Vestibulares , Humanos , Miastenia Gravis/diagnóstico , Miastenia Gravis/fisiopatologia , Miastenia Gravis/complicações , Masculino , Feminino , Diplopia/diagnóstico , Diplopia/fisiopatologia , Diplopia/etiologia , Pessoa de Meia-Idade , Potenciais Evocados Miogênicos Vestibulares/fisiologia , Adulto , Blefaroptose/diagnóstico , Blefaroptose/fisiopatologia , Blefaroptose/etiologia , Idoso , Estudos Prospectivos , Eletromiografia/métodos , Sensibilidade e Especificidade , Músculos Oculomotores/fisiopatologia , Adulto Jovem
6.
Int Ophthalmol ; 44(1): 206, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38678129

RESUMO

PURPOSE: Patients with thyroid eye disease (TED) can present with asymmetric disease. The purpose of this study was to evaluate the prevalence of asymmetric TED in an Australian cohort and investigate clinical, biochemical, and radiological associations of asymmetric TED. METHODS: This was a retrospective study of patients with TED who underwent Hertel exophthalmometry and orbital computed tomography (CT) scans. Asymmetry was defined as a difference in the globe protrusion of ≥ 3 mm using Hertel exophthalmometry. Data was collected on patient demographics, clinical disease presentation, thyroid function tests and antibody levels. Muscles volumes were determined by manually segmenting the extraocular muscles on CT scans using a commercially available software. RESULTS: 172 orbits from 86 patients were included in the study. 28 (33%) patients had asymmetric TED. No significant differences were observed in age, gender, thyroid hormone status, anti-thyroid peroxidase levels, thyroid stimulating hormone receptor antibodies, disease activity status, or dysthyroid optic neuropathy between the asymmetric and non-asymmetric groups. The extraocular muscle volumes were significantly higher in the asymmetric orbit compared to its contralateral orbit. CONCLUSION: Asymmetric TED is a reasonably common occurrence in the course of TED. It is associated with higher extraocular muscle volumes, suggesting muscle enlargement as one of the underlying contributors to asymmetric proptosis. Thyroid eye disease should be considered in the differential of asymmetric orbital inflammatory disease.


Assuntos
Exoftalmia , Oftalmopatia de Graves , Músculos Oculomotores , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Estudos Retrospectivos , Exoftalmia/diagnóstico , Oftalmopatia de Graves/diagnóstico , Oftalmopatia de Graves/complicações , Pessoa de Meia-Idade , Músculos Oculomotores/fisiopatologia , Músculos Oculomotores/diagnóstico por imagem , Músculos Oculomotores/patologia , Idoso , Adulto , Órbita/diagnóstico por imagem , Prevalência , Idoso de 80 Anos ou mais , Austrália/epidemiologia
7.
Strabismus ; 32(1): 39-47, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38311603

RESUMO

INTRODUCTION: The aim of this study is to evaluate changes in corneal astigmatism, axial anterior corneal curvature, as well as changes in the anterior chamber depth and central corneal thickness, 2 months following the unilateral recession of medial rectus muscle in children. METHODS: Thirty-three children with esotropia were prospectively evaluated following unilateral medial rectus muscle recession, using Pentacam®. Comparisons were made between the operated and fellow unoperated eyes, pre, and postoperatively. The assessment was made for changes in the radius of axial curvature on major meridians at 3 and 3.5 mm from the optical corneal center in the mid-peripheral zone. Astigmatism changes of the anterior and posterior corneal surface were calculated using vector analysis software (astigMATIC®). ANOVA model was used to examine the interaction between age or central corneal thickness and postoperative changes in anterior and posterior surface corneal astigmatism. RESULTS: In the intervention group, changes in anterior and posterior corneal surface astigmatism were statistically significant, with a mean increase of 0.59Dx92 and 0.08Dx91, respectively. In the mid-peripheral corneal zone, there is an increase in the radius of anterior corneal axial curvature more evident nasally 3.5 mm from the corneal center on the horizontal meridian, with corresponding decrease superiorly and inferiorly at 3 and 3.5 mm from the corneal center on the vertical meridian. DISCUSSION: The changes in total astigmatism of the operated eyes are mainly attributed to the anterior corneal surface. These changes are associated with flattening in the 180 meridian of the cornea, leading to a shift to "with-the-rule" astigmatism.


Assuntos
Astigmatismo , Córnea , Músculos Oculomotores , Humanos , Estudos Prospectivos , Masculino , Feminino , Córnea/patologia , Córnea/diagnóstico por imagem , Criança , Músculos Oculomotores/cirurgia , Músculos Oculomotores/fisiopatologia , Músculos Oculomotores/diagnóstico por imagem , Pré-Escolar , Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Procedimentos Cirúrgicos Oftalmológicos/métodos , Esotropia/fisiopatologia , Esotropia/cirurgia , Topografia da Córnea , Adolescente , Acuidade Visual/fisiologia
8.
Strabismus ; 32(1): 48-53, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38357815

RESUMO

INTRODUCTION: Progressive esotropia accompanied by restricted abduction and supraduction due to high myopia is known as esotropia fixus with high myopia or heavy eye syndrome (HES). Some conditions, such as sagging eye syndrome (SES), show esotropia for distance or cyclovertical strabismus with no abduction limitations despite highly myopic eyes. We evaluated the magnetic resonance imaging (MRI) findings and clinical features of HES, high myopia with SES-like symptoms (highly myopic SES), and SES. METHODS: We reviewed all patients diagnosed with HES, highly myopic SES, and SES who underwent MRI of the orbits and brain over 6 years. To quantitatively assess the orbital anatomy, we compared the conditions of the superior rectus muscle (SR), lateral rectus muscle (LR), and inferior rectus muscle (IR) using orbital MRI among the three groups. RESULTS: Among the 14 patients (27 eyes) with high myopia, 5 (9 eyes) had HES, and 9 (18 eyes) had highly myopic SES. Eleven patients (22 eyes) with SES were also compared with these 14 patients. The mean axial length was 29.6 ± 1.0 mm in participants with HES, 29.0 ± 1.5 mm in those with HES-SES, and 23.7 ± 0.9 mm in those with SES. The average distance esotropia was 48.0 ± 19.9Δprism, 4.6 ± 1.5Δprism, and 6.1 ± 4.6Δprism for participants with HES, highly myopic SES and SES, respectively. The average distance hypertropia was 5.3 ± 5.9Δprism in participants with highly myopic SES and 4.8 ± 2.7Δprism in those with SES. The mean vertical angle of the LR was 32.6 ± 10.8°, 18.1 ± 5.4°, and 14.6 ± 6.8°; the mean tilting angle of the LR was 31.6 ± 9.2°, 15.9 ± 6.0°, and 13.8 ± 5.9°; and the mean displacement angle between the LR and SR was 152.3 ± 16.7°, 125.0 ± 7.1°, and 112.5 ± 7.5° for participants with HES, highly myopic SES and SES, respectively. The LR-SR displacement angle in HES-SES was significantly larger than in SES (p < .001) but the vertical and tilting angles were not. Also, the IR shift showed no significant difference with HES-SES and HES (5.8 ± 1.4 mm and 5.3 ± 1.2 mm) but not with SES (4.0 ± 0.8 mm) (p < .0001). DISCUSSION: SES-like symptoms can develop in highly myopic eyes; however, MRI showed that the state of the LR muscle in highly myopic SES deviated almost similarly to that in SES; however, the eyeball was more dislocated than in SES. This may be useful in deciding the appropriate operative procedure.


Assuntos
Esotropia , Imageamento por Ressonância Magnética , Miopia Degenerativa , Músculos Oculomotores , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Feminino , Músculos Oculomotores/diagnóstico por imagem , Músculos Oculomotores/fisiopatologia , Esotropia/fisiopatologia , Esotropia/diagnóstico por imagem , Esotropia/etiologia , Adulto , Miopia Degenerativa/complicações , Miopia Degenerativa/fisiopatologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem , Síndrome , Idoso , Adolescente , Órbita/diagnóstico por imagem , Miopia/complicações , Miopia/fisiopatologia , Movimentos Oculares/fisiologia
9.
Strabismus ; 32(1): 30-38, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38380479

RESUMO

PURPOSE: To evaluate the clinical profile of myopic strabismus fixus (MSF) in children and surgical outcomes of silicone band loop myopexy. METHOD: We retrospectively reviewed records of children presenting with MSF who underwent silicone band loop myopexy between January 2008 and December 2020 at a tertiary eye care center. Data concerning demographics, refractive error, axial length, extra-ocular motility, and ocular alignment pre-operatively and post-operatively, intra- and post-operative complications, ocular and systemic associations, were evaluated. The long-term effects of band loop myopexy on ocular alignment stability, motility improvement, and myopia progression were analyzed. Surgical outcome was defined as post-operative orthotropia or heterotropia less than or equal to 20 PD. RESULTS: A total of0 eyes of 7 patients (median age: 5 years; 5 boys and 2 girls) who underwent band loop myopexy were included in the study. Among them, three children underwent bilateral and four children underwent unilateral band loop myopexy. Medial rectus recession was performed only in two patients as a part of initial procedure. The median follow-up duration was 7 years. Most of the children, i.e. six of them presented with esotropia-hypotropia and only one patient presented with exotropia-hypotropia complex. The median pre-operative measurements were esotropia of 62.5 PD, hypotropia of5 PD, and exotropia of4 PD. Postoperative average primary position deviation measured was close to 9-10 PD of esotropia. The overall motility improved to -1 from -3. CONCLUSION: The clinical profile of MSF in children is almost similar to adults. This condition is a rare entity among adults as well as children. Majority of children with MSF presented with esotropia-hypotropia complex. Silicone band loop myopexy with or without medial rectus recession proves to be a reliable surgical procedure as it provides stable outcomes in terms of ocular alignment and motility among children.


Assuntos
Miopia , Músculos Oculomotores , Procedimentos Cirúrgicos Oftalmológicos , Humanos , Masculino , Feminino , Estudos Retrospectivos , Músculos Oculomotores/cirurgia , Músculos Oculomotores/fisiopatologia , Criança , Miopia/cirurgia , Miopia/fisiopatologia , Miopia/complicações , Pré-Escolar , Procedimentos Cirúrgicos Oftalmológicos/métodos , Resultado do Tratamento , Visão Binocular/fisiologia , Movimentos Oculares/fisiologia , Seguimentos , Acuidade Visual/fisiologia , Elastômeros de Silicone , Estrabismo/cirurgia , Estrabismo/fisiopatologia , Estrabismo/etiologia , Refração Ocular/fisiologia
10.
Eur J Ophthalmol ; 34(3): 874-879, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38361386

RESUMO

BACKGROUND: Besides rest position abnormalities, exotropia could also be due to hypertonia of the Lateral Recti (LR) given divergence frequently decreases under general anesthesia (GA). Combined Recession-Resection of the Same Muscle (RRSM) is a promising alternative to the Faden procedure in the surgical treatment of overacting MR in esotropia. We thus examined here the effectiveness of combined RRSM of the LR for the treatment of exotropia that decrease under GA. METHODS: We performed a retrospective, single-center evaluation over a 16-month period of 100 patients operated on for exotropia that decreased under deep GA (91% of 110 consecutive operated cases). We excluded re-operations and pure convergence insufficiencies. We performed a combined RRSM of one or two LR. It included a 10mm-recession and a "fine-tuned" resection of LR based on Quantitative Forced Duction Test scores. MR resection was combined when exotropia exceeded 35PD or for unilateral surgery. We report on patient outcomes 6 months after surgery. RESULTS: Successful results were obtained (-8-+8 PD measured on Alternate Cover Test) among 83% of cases at distance fixation and 91% at near fixation after 6 months. The Newcastle Control Score also improved from 5.8 to 1.7 after 6 months. No surgery-related complications or repeat surgeries were reported. CONCLUSIONS: In our experience a majority of exotropias decrease under GA and our strategy of combined RRSM of the LR is effective for the treatment of such exotropias. Long-term follow-up of the cohort is required to investigate the stability of these outcomes, and confirmation of our results by other works.


Assuntos
Exotropia , Músculos Oculomotores , Procedimentos Cirúrgicos Oftalmológicos , Visão Binocular , Humanos , Exotropia/cirurgia , Exotropia/fisiopatologia , Músculos Oculomotores/cirurgia , Músculos Oculomotores/fisiopatologia , Estudos Retrospectivos , Masculino , Feminino , Visão Binocular/fisiologia , Criança , Pré-Escolar , Adolescente , Adulto , Resultado do Tratamento , Acuidade Visual/fisiologia , Adulto Jovem , Pessoa de Meia-Idade , Seguimentos , Movimentos Oculares/fisiologia
11.
Am J Ophthalmol ; 262: 186-191, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38191066

RESUMO

PURPOSE: To investigate the results of patients undergoing surgical treatment for strabismic diplopia in thyroid eye disease (TED) following teprotumumab. DESIGN: Multicenter, retrospective, case series. METHODS: We report 28 patients who underwent extraocular muscle surgery for strabismic diplopia after treatment with teprotumumab at 7 different academic centers. Elapsed time from last teprotumumab dose to the date of surgery, previous orbital decompression, primary preoperative horizontal and vertical deviation, surgical procedure, and 2-month postoperative results were collected from the patient records. RESULTS: Sixteen (57%) patients were diplopia-free after 1 surgery. Three (11%) chose prism spectacles to correct residual diplopia, 2 (7%) used compensatory head posture to resolve diplopia, and 1 (4%) had intermittent diplopia and was functionally improved (choosing no prisms or further surgery). These were considered treatment successes. Three (11%) patients required reoperation, and all were diplopia-free after their second procedure. CONCLUSIONS: Most patients requiring surgery for strabismic diplopia following teprotumumab achieve good outcomes with success rates comparable to series published before the availability of teprotumumab.


Assuntos
Anticorpos Monoclonais Humanizados , Diplopia , Oftalmopatia de Graves , Músculos Oculomotores , Estrabismo , Humanos , Estudos Retrospectivos , Masculino , Feminino , Músculos Oculomotores/cirurgia , Músculos Oculomotores/fisiopatologia , Pessoa de Meia-Idade , Oftalmopatia de Graves/cirurgia , Oftalmopatia de Graves/tratamento farmacológico , Diplopia/fisiopatologia , Estrabismo/cirurgia , Estrabismo/fisiopatologia , Anticorpos Monoclonais Humanizados/uso terapêutico , Idoso , Adulto , Resultado do Tratamento , Procedimentos Cirúrgicos Oftalmológicos , Descompressão Cirúrgica , Visão Binocular/fisiologia
12.
Ophthalmic Plast Reconstr Surg ; 40(3): 326-330, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38215464

RESUMO

PURPOSE: To compare clinical outcomes of transconjunctival Müller's muscle recession with levator disinsertion (TMRLD) to the traditional gold weight implantation in patients with paralytic lagophthalmos. METHODS: A retrospective nonrandomized comparative review of patients who had gold weight implantation and TMRLD surgeries for paralytic lagophthalmos from January 2016 to January 2023 was performed. The main outcome comparisons were measurement changes in lagophthalmos, marginal reflex distance 1, visual acuity, and corneal examination. Complication and reoperation rates were also compared. RESULTS: Twenty-six cases of gold weight implantation and 20 cases of TMRLD surgeries were identified. The changes in logMAR visual acuity between gold weight implantation and TMRLD groups were not statistically significant (-0.10 ± 0.48 vs. +0.05 ± 0.14, p > 0.05). The percent improvement in lagophthalmos (62.2% ± 51.8% vs. 58.4% ± 21.1%) and final marginal reflex distance 1 (2.22 ± 1.42 vs. 2.25 ± 1.41 mm) were also comparable between groups ( p > 0.05). Both groups showed similar changes in marginal reflex distance 1 (1.75 ± 1.31 vs. 2.83 ± 1.37 mm) and lagophthalmos (3.77 ± 3.92 vs. 3.36 ± 1.36 mm) ( p > 0.05). The overall complication (15.4% vs. 15.0%) and reoperation rates (15.4% vs. 15.0%) were comparable over the follow-up duration (291.6 ± 437.3 vs. 121.0 ± 177.8 days) ( p > 0.05). CONCLUSION: TMRLD is as safe and effective as the gold weight implantation in addressing paralytic lagophthalmos in patients with facial nerve palsy.


Assuntos
Paralisia Facial , Ouro , Músculos Oculomotores , Humanos , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Músculos Oculomotores/cirurgia , Músculos Oculomotores/fisiopatologia , Adulto , Paralisia Facial/cirurgia , Paralisia Facial/complicações , Paralisia Facial/fisiopatologia , Pálpebras/cirurgia , Idoso , Resultado do Tratamento , Doenças Palpebrais/cirurgia , Doenças Palpebrais/etiologia , Doenças Palpebrais/fisiopatologia , Túnica Conjuntiva/cirurgia , Implantação de Prótese/métodos , Blefaroplastia/métodos , Acuidade Visual , Procedimentos Cirúrgicos Oftalmológicos/métodos , Lagoftalmia
13.
Graefes Arch Clin Exp Ophthalmol ; 262(6): 1919-1924, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38294512

RESUMO

PURPOSE: Dysthyroid optic neuropathy (DON) leads to vision loss. This study aimed to investigate a new method that can directly evaluate the change in muscle cone inner volume (MCIV) and distinguish DON orbits from non-DONs. MATERIALS AND METHODS: This study included 54 patients (108 orbits) who were diagnosed with thyroid eye disease and treated at the Beijing Tongren Hospital between December 2019 and September 2021. The extraocular muscle volume (EOMV), orbital fat volume (OFV), and bony orbit volume (BOV) of the patients were measured using three-dimensional reconstruction. MCIV was measured using artificially defined boundaries. The associations between these volumes and clinical indicators were studied, and the diagnostic efficacy of these volumes for DON was described using receiver operating characteristic (ROC) curves. RESULTS: The ROC curve showed that the area under the curve of MCIV/BOV (%) combined with EOMV/BOV (%) reached 0.862 (p < 0.001), with a sensitivity of 85.7% and a specificity of 76.1%. CONCLUSION: The combination of MCIV/BOV (%) and EOMV/BOV (%) is a good indicator for the diagnosis of DON, which aids in the early detection and intervention of DON.


Assuntos
Oftalmopatia de Graves , Imageamento Tridimensional , Músculos Oculomotores , Doenças do Nervo Óptico , Órbita , Curva ROC , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Oftalmopatia de Graves/diagnóstico , Oftalmopatia de Graves/cirurgia , Doenças do Nervo Óptico/diagnóstico , Órbita/diagnóstico por imagem , Estudos Retrospectivos , Músculos Oculomotores/cirurgia , Músculos Oculomotores/fisiopatologia , Adulto , Idoso , Tomografia Computadorizada por Raios X/métodos
14.
Ophthalmology ; 129(1): 100-109, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34446304

RESUMO

PURPOSE: To review the scientific literature that evaluates the effectiveness of adjustable sutures in the management of strabismus for adult and pediatric patients. METHODS: Literature searches were performed in the PubMed database through April 2021 with no date limitations and were restricted to publications in English. The searches identified 551 relevant citations, of which 55 were reviewed in full text. Of these, 17 articles met the inclusion criteria and were assigned a level of evidence rating by the panel methodologist. The search included all randomized controlled studies regardless of study size and cohort studies of 100 or more patients comparing the adjustable versus nonadjustable suture technique, with a focus on motor alignment outcomes or reoperation rates. RESULTS: The literature search yielded no level I studies. Of the 17 articles that met the inclusion criteria, 11 were rated level II and 6 were rated level III. Among the 12 studies that focused on motor alignment outcomes, 4 small randomized clinical trials (RCTs) did not find a statistically significant difference between groups, although they were powered to detect only very large differences. Seven of 8 nonrandomized studies found a statistically significant difference in motor alignment success in favor of the adjustable suture technique, both overall and in certain subgroups of patients. Successful motor alignment was seen in both exotropia (in 3 studies that were not limited to children) and esotropia (in 1 study of adults and 2 of children). The majority of included studies that reported on reoperation rates found the rates to be lower in patients who underwent strabismus surgery with adjustable sutures, but this finding was not uniformly demonstrated. CONCLUSIONS: Although there are no level I studies evaluating the effectiveness of adjustable sutures for strabismus surgery, the majority of nonrandomized studies that met the inclusion criteria for this assessment reported an advantage of the adjustable suture technique over the nonadjustable technique with respect to motor alignment outcomes. This finding was not uniformly demonstrated among all studies reviewed and warrants further investigation in the development and analysis of adjustable suture techniques.


Assuntos
Músculos Oculomotores/cirurgia , Estrabismo/cirurgia , Técnicas de Sutura , Academias e Institutos/normas , Adulto , Criança , Humanos , Músculos Oculomotores/fisiopatologia , Procedimentos Cirúrgicos Oftalmológicos , Oftalmologia/organização & administração , Estrabismo/fisiopatologia , Suturas , Avaliação da Tecnologia Biomédica , Estados Unidos , Visão Binocular/fisiologia
15.
Sci Rep ; 11(1): 23934, 2021 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-34907246

RESUMO

Extraocular muscle movement during strabismus surgery causes changes in eyeball shape. Because extraocular muscle insertion is in front of the equator, it is thought that changes due to strabismus surgery mainly occur in the anterior segment. However, changes in the posterior segment of eye may also occur, which may also result in changes in refractive error after strabismus surgery. Using a 3-dimensional reconstruction technique (en face imaging) of the swept source optical coherence tomography, we determined and quantitatively measured the posterior polar change. The deepest interface between Bruch's membrane and the choroid could be identified as the deepest point of the eyeball (DPE), and the location of the DPE relative to the optic disc and the fovea was measured. After lateral rectus muscle recession, the DPE moved away from the fovea, but after medial rectus muscle recession, the DPE moved toward the fovea. The amount of DPE movement differed by age and preoperative refractive error. Our findings suggest that the positional shift of the rectus muscle in horizontal strabismus surgery causes a structural change in the posterior segment of the eye, and the postoperative refractive changes may be related to this shift.


Assuntos
Músculos Oculomotores , Procedimentos Cirúrgicos Oftalmológicos , Estrabismo , Tomografia de Coerência Óptica , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Músculos Oculomotores/diagnóstico por imagem , Músculos Oculomotores/fisiopatologia , Músculos Oculomotores/cirurgia , Estrabismo/diagnóstico por imagem , Estrabismo/fisiopatologia , Estrabismo/cirurgia
16.
Biomed Res Int ; 2021: 1837458, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34840967

RESUMO

OBJECTIVE: To explore the role of conjoint fascial sheath (CFS) suspension in the treatment of severe ptosis. METHODS: A total of 110 patients with severe ptosis who were admitted to our hospital from May 2018 to December 2020 were included. Fifty-seven patients treated with frontalis suspension were assigned into group A, and the remaining 53 patients treated with CFS suspension were assigned into group B. The curative effect, ocular surface alterations, complications, and satisfaction in the two groups were compared. RESULTS: Patients in group B suffered from severe upper eyelid retraction and lid lag than those in group A, as well as more limited range of motion (ROM) (P < 0.05). The curative effect and patient satisfaction in group B were higher than those in group A (P < 0.05). Postsurgical complications in group B were fewer than those in group A (P < 0.05). CONCLUSION: CFS suspension is effective in the treatment of severe ptosis.


Assuntos
Blefaroplastia/métodos , Blefaroptose/cirurgia , Adolescente , Adulto , Blefaroplastia/efeitos adversos , Blefaroptose/fisiopatologia , Pálpebras/fisiopatologia , Pálpebras/cirurgia , Fasciotomia/métodos , Feminino , Humanos , Masculino , Músculos Oculomotores/fisiopatologia , Músculos Oculomotores/cirurgia , Satisfação do Paciente , Complicações Pós-Operatórias/etiologia , Índice de Gravidade de Doença , Resultado do Tratamento , Adulto Jovem
17.
Invest Ophthalmol Vis Sci ; 62(10): 35, 2021 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-34459850

RESUMO

Purpose: Research on infantile nystagmus syndrome (INS) and velocity discrimination is limited, and no research has examined velocity discrimination in subjects with INS at their null position and away from it. This study aims to investigate how individuals with INS perform, compared with controls, when carrying out velocity discrimination tasks. Particularly, the study aims to assess how the null position affects their performance. Methods: INS subjects (N = 21, mean age 24 years; age range, 15-34 years) and controls (N = 16, mean age 26 years; age range, 22-39 years) performed horizontal and vertical velocity discrimination tasks at two gaze positions. Eighteen INS subjects were classified as idiopathic INS and three had associated visual disorders (two had oculocutaneous albinism, and one had congenital cataract). For INS subjects, testing was done at the null position and 15° away from it. If there was no null, testing was done at primary gaze position and 15° away from primary. For controls, testing was done at primary gaze position and 20° away from primary. Horizontal and vertical velocity discrimination thresholds were determined and analyzed. Results: INS subjects showed significantly higher horizontal and vertical velocity discrimination thresholds compared with controls at both gaze positions (P < 0.001). Horizontal thresholds for INS subjects were elevated more than vertical thresholds (P < 0.0001) for INS subjects but not for controls. Within the INS group, 12 INS subjects who had an identified null position showed significantly lower horizontal and vertical thresholds at the null than at 15° away from it (P < 0.05). Conclusions: Velocity discrimination was impaired in INS subjects, with better performance at the null. These findings could assist in understanding how INS affects the daily activities of patients in tasks involving moving objects, and aid in developing new clinical visual function assessments for INS.


Assuntos
Movimentos Oculares/fisiologia , Doenças Genéticas Ligadas ao Cromossomo X/fisiopatologia , Nistagmo Congênito/fisiopatologia , Músculos Oculomotores/fisiopatologia , Acuidade Visual , Adolescente , Adulto , Feminino , Humanos , Masculino , Síndrome , Adulto Jovem
18.
Muscle Nerve ; 64(3): 328-335, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34131928

RESUMO

INTRODUCTION/AIMS: Videonystagmography (VNG) which directly records eye movements using infrared video goggles with mini-cameras, is used to measure nystagmus. Our aim is to explore whether VNG can be used to detect a decrement in the extraocular muscle (EOM) activity of patients with myasthenia gravis (MG). METHODS: Thirty-four patients with MG, including 13 with ocular-predominant and 21 with generalized MG, and 23 healthy controls participated. Using VNG we recorded the velocity of the eye movements of the patients as they followed a moving target. We then calculated the gain by dividing the eye movement velocity (degrees/second) by the target velocity (degrees/second). RESULTS: In MG subjects, the mean initial gain (maximum gain) was 1.23 ± 0.31 (range: 0.63-2.15) for the right eye and 1.22 ± 0.37 (range; 0.60-2.28) for the left eye. The mean minimum gain was 0.11 ± 0.12 (0.01-0.58) for the right and 0.14 ± 0.5 (0.02-0.55) for the left. Due to fatigue, the movement gain was reduced by 91.7% in the right eye and 88.2% in the left eye. After reaching minimum velocity, gain remained at a minimum for a mean of 1.08 ± 0.52 (0.3-2.4) s for the right and 1.49 ± 0.85 (0.4-3.6) s for the left, before the velocity increased again. There was no fatigue-induced decrement in healthy subjects. DISCUSSION: Our study documents a decrement in EOM activity recorded by VNG in patients with MG which begins to improve within 1-2 s after reaching minimum velocity, analogous to traditional low-frequency repetitive nerve stimulation testing and its U-shaped pattern. Thus, VNG may be a promising diagnostic test for MG.


Assuntos
Medições dos Movimentos Oculares , Movimentos Oculares/fisiologia , Miastenia Gravis/diagnóstico , Músculos Oculomotores/fisiopatologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miastenia Gravis/fisiopatologia , Adulto Jovem
19.
World Neurosurg ; 152: 56-60, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34139352

RESUMO

BACKGROUND: We describe a continuous monitoring method aimed at preserving nerve function during biopsy of lesions on the oculomotor nerve using stimulation of the oculomotor nerve proximal to the lesion. CASE DESCRIPTION: A 5-year-old girl with a recurrent left oculomotor nerve palsy and contrast-enhancing left oculomotor nerve mass on magnetic resonance imaging underwent a biopsy of the lesion to aid in its diagnosis. At the time of surgery, needle electrodes were inserted into the superior and inferior rectus muscles percutaneously, and cotton-covered electrodes were implanted into the oculomotor nerve proximal to the lesion. Compound muscle action potentials of the oculomotor nerve were measured continuously by monopolar stimulation. The lesion was mapped by direct stimulation, and the unresponsive area was excised. The amplitude of the compound muscle action potentials decreased during the resection but recovered postoperatively. After resection of the lesion, the compound muscle action potentials remained the same as they were preoperatively. No obvious postoperative oculomotor nerve palsy was observed. CONCLUSIONS: This method of continuous monitoring of the function of the oculomotor nerve is simple to use and is suitable for lesions in close proximity to the oculomotor nerve.


Assuntos
Estimulação Elétrica/métodos , Hamartoma/cirurgia , Monitorização Neurofisiológica Intraoperatória/métodos , Doenças do Nervo Oculomotor/cirurgia , Potenciais de Ação/fisiologia , Biópsia/métodos , Pré-Escolar , Feminino , Hamartoma/etiologia , Humanos , Músculos Oculomotores/fisiopatologia , Doenças do Nervo Oculomotor/etiologia , Síndrome de Tolosa-Hunt/complicações
20.
Ophthalmology ; 128(12): 1766-1776, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34176652

RESUMO

PURPOSE: To review the available evidence comparing the effectiveness of extraocular muscle botulinum toxin type A (BTXA) injection with eye muscle surgery for restoring ocular alignment in children and adults with nonparalytic, nonrestrictive horizontal strabismus. METHODS: Literature searches in the PubMed Cochrane Library, and clinical trial databases with no date restrictions, but limited to articles published in English, were conducted last on January 10, 2021. The searches yielded 515 citations, 40 of which were reviewed in full text by the first author. Fourteen articles met the criteria for inclusion (randomized or nonrandomized comparative studies, or case series with a minimum 50 patients; evaluating extraocular muscle BTXA injection for initial or repeat treatment of horizontal, nonparalytic, nonrestrictive strabismus; with at least 6 months of follow-up) and were graded by a methodologist. RESULTS: The 14 included studies consisted of 2 randomized clinical trials, 3 nonrandomized comparative studies, and 9 case series. All 5 comparative studies were graded level II evidence, and the 9 case series were graded level III evidence. Successful motor outcomes after BTXA injection were relatively consistent across 4 of the 5 comparative studies at 60%, when adjustment was made for differential selection bias in 1 of the studies. In the 4 studies, successful motor outcomes after surgery ranged from 66% to 77% with a mean follow-up of 23 to 75 months, and the outcomes were not significantly different from those after BTXA injection. In the fifth level II study, success was significantly higher with BTXA injection than with surgery (94% vs. 72%). The level III BTXA case series demonstrated higher motor success rates of 87% to 89% when children were treated in 2 muscles at a time; rates were lower in adults treated with single-muscle BTXA injection. CONCLUSIONS: Extraocular muscle injection of BTXA achieves a high rate of successful motor alignment, comparable with that achieved after eye muscle surgery for nonparalytic, nonrestrictive horizontal strabismus. Good alignment may require multiple BTXA injections, and it is not yet clear whether sensory outcomes are equivalent for BTXA injections versus eye muscle surgery in young children.


Assuntos
Academias e Institutos , Toxinas Botulínicas Tipo A/administração & dosagem , Fármacos Neuromusculares/administração & dosagem , Músculos Oculomotores/efeitos dos fármacos , Oftalmologia/organização & administração , Estrabismo/tratamento farmacológico , Pré-Escolar , Feminino , Humanos , Injeções Intramusculares , Masculino , Músculos Oculomotores/fisiopatologia , Músculos Oculomotores/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Ensaios Clínicos Controlados Aleatórios como Assunto , Estrabismo/fisiopatologia , Estrabismo/cirurgia , Avaliação da Tecnologia Biomédica , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA