Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
2.
Medicine (Baltimore) ; 103(7): e33857, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38363896

RESUMO

RATIONALE: Uterine perforation is a serious complication of intrauterine contraceptive device (IUD) placement. However, as complete uterine perforation and extrauterine migration may remain asymptomatic, thorough localization of the IUD is important prior to reinsertion. PATIENT CONCERNS: A 33-year-old patient who has had 4 IUD insertions, wherein the location of the first IUD (inserted 14 years ago) was not identified prior to reinsertion and replacement of the subsequent three. She presented to hospital with a 6-month history of abdominal pain. Pelvic ultrasonography (US), radiography, hysteroscopy and laparoscopy examinations confirmed that a retained migrated IUD in the right broad ligament. DIAGNOSIS: Uterine perforation, IUD migration to the broad ligament. INTERVENTIONS: The patient underwent hysteroscopy and laparoscopy. OUTCOMES: Both IUDs were successfully removed without any complications.


Assuntos
Ligamento Largo , Migração de Dispositivo Intrauterino , Dispositivos Intrauterinos , Perfuração Uterina , Feminino , Humanos , Adulto , Perfuração Uterina/diagnóstico por imagem , Perfuração Uterina/etiologia , Migração de Dispositivo Intrauterino/efeitos adversos , Dispositivos Intrauterinos/efeitos adversos , Radiografia
3.
Urol Int ; 108(3): 272-275, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38377979

RESUMO

INTRODUCTION: Approximately 5% of bladder stones occur in women and are usually associated with foreign bodies or urinary stasis. Spontaneous migration of the intrauterine device (IUD) into the bladder is a rare complication. In this report, we present 2 cases of migrated IUD who had undergone surgery at our clinic due to bladder stones. CASE PRESENTATIONS: We detected migrated IUDs into the bladder in 2 female patients, aged 37 and 56 years, who presented with lower urinary tract symptoms and urinary tract infection. In the first case, endoscopic cystolithotripsy was performed, and the IUD was removed without complications. In the second case, the IUD could not be removed endoscopically since it had fractionally invaded the bladder wall, and the IUD was removed without complications by performing an open cystolithotomy. CONCLUSION: A comprehensive gynecological history should be taken from every female patient presenting with recurrent urinary tract infections and lower urinary tract symptoms. If these patients have a history of IUD placement, the possibility of the intravesical migration of this device should be kept in mind.


Assuntos
Migração de Dispositivo Intrauterino , Dispositivos Intrauterinos , Litotripsia , Cálculos da Bexiga Urinária , Humanos , Feminino , Cálculos da Bexiga Urinária/etiologia , Cálculos da Bexiga Urinária/cirurgia , Adulto , Pessoa de Meia-Idade , Dispositivos Intrauterinos/efeitos adversos , Migração de Dispositivo Intrauterino/efeitos adversos , Litotripsia/efeitos adversos , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/cirurgia , Bexiga Urinária/cirurgia , Cistoscopia , Remoção de Dispositivo , Infecções Urinárias/etiologia , Resultado do Tratamento
4.
BMJ Case Rep ; 16(10)2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37879705

RESUMO

An intrauterine device (IUD) is a popular method of contraception mainly used in developing countries. Perforation is one of the most serious but a rare complication secondary to the insertion of an IUD, while perforation into the intravesical organs such as the bladder is even more rare. A 30-year-old multipara in early 30s, with two previous caesarean sections (CS) and one curettage, was found to have her IUD puncturing the bladder during a cystoscopy procedure to remove her bladder stones. Transvesical migration of an IUD is an uncommon complication with a high rate of calculi formation, which is thought to be caused by the IUD's lithogenic potential. Imaging approaches such as ultrasound and pelvic X-rays are considered imperative in the accurate diagnosis. Any migrated IUD should be removed regardless of location. Prompt and continual monitoring of women using an IUD is essential and in a case where the IUD has migrated, the removal using the endoscopic approach is a safe and effective method.


Assuntos
Migração de Dispositivo Intrauterino , Cálculos da Bexiga Urinária , Adulto , Feminino , Humanos , Cistoscopia/efeitos adversos , Migração de Dispositivo Intrauterino/efeitos adversos , Dispositivos Intrauterinos , Bexiga Urinária/lesões , Cálculos da Bexiga Urinária/diagnóstico por imagem , Cálculos da Bexiga Urinária/etiologia , Cálculos da Bexiga Urinária/cirurgia
6.
Pan Afr Med J ; 42: 175, 2022.
Artigo em Francês | MEDLINE | ID: mdl-36187042

RESUMO

Intrauterine device (IUD) is the mainstay of family planning methods in developing countries. However, it is associated with severe complications such as bleeding, perforation and migration to adjacent organs. Although perforation of the uterus is not rare, migration to the sigmoid colon is exceptional. We here report a case of IUD migration into sigmoid colon; this was removed via low endoscopy. The study involved a 45-year-old woman using an IUD who presented with pelvic pain associated with a feeling of pelvic heaviness 6 years later of insertion. Clinical examination was without abnormalities, and computed tomography (CT) scan showed the IUD embedded in the sigmoid colon wall. Diagnostic and therapeutic laparoscopy was performed, which objectified IUD-related intestinal perforation. IUD was partially embedded in the sigmoid colon wall and couldn't be removed. The device was removed during colonoscopy by diathermy loop excision (15 mm in diameter).


Assuntos
Migração de Dispositivo Intrauterino , Dispositivos Intrauterinos , Laparoscopia , Perfuração Uterina , Colo Sigmoide/cirurgia , Remoção de Dispositivo/métodos , Feminino , Humanos , Migração de Dispositivo Intrauterino/efeitos adversos , Dispositivos Intrauterinos/efeitos adversos , Laparoscopia/métodos , Pessoa de Meia-Idade , Perfuração Uterina/etiologia , Perfuração Uterina/cirurgia
7.
Rev. chil. obstet. ginecol. (En línea) ; 86(2): 241-246, abr. 2021. ilus
Artigo em Espanhol | LILACS | ID: biblio-1388644

RESUMO

RESUMEN El dispositivo intrauterino (DIU) es un método anticonceptivo muy popular, eficaz y seguro. Aunque posee complicaciones bien descritas como es la migración, la que puede ser a otros órganos dentro de la cavidad peritoneal. La fístula uteroyeyunal es un evento clínico poco frecuente, pero de gran repercusión si no es diagnosticada y tratada. Se presenta el caso de una paciente usuaria de DIU, el que migra a cavidad abdominal, con posterior formación de fístula uteroyeyunal.


ABSTRACT The intrauterine device is a popular, efficient and safe contraceptive. Although it has some well described complications, such as migration, which may be to the different organs inside of the peritoneal cavity. The uterus-jejunal fistula is a rare clinical event, but with great repercussion if it is not well assessed and treated properly. We present the clinical case of a patient with a migrated intrauterine device and a fistula uterus-jejunal formation.


Assuntos
Humanos , Feminino , Adulto , Doenças Uterinas/etiologia , Migração de Dispositivo Intrauterino/efeitos adversos , Fístula/etiologia , Doenças do Jejuno/etiologia , Doenças Uterinas/cirurgia , Laparoscopia , Fístula/cirurgia , Perfuração Intestinal , Doenças do Jejuno/cirurgia
8.
Ned Tijdschr Geneeskd ; 1652021 02 25.
Artigo em Holandês | MEDLINE | ID: mdl-33651491

RESUMO

BACKGROUND: The Implanon NXT is a commonly used contraceptive. Incorrect localization of the implant can cause complications. CASE DESCRIPTION: A 41-year-old woman is seen in the gynaecology outpatient clinic with a request to remove a recently placed Implanon NXT because of worsening mood symptoms. The implant can't be found on physical and ultrasound examination. Duringsurgicalexplorationthe implant is not found at theinsertion site' By means of X-ray scanning the implant becomes visible around the humeral head. The implant appears to be located in the cephalic vein and is subsequently removed. CONCLUSION: In case of a referral due to because of worsening mood symptoms after an Implanon NXT exchange, it is possible that the implant is localized incorrectly. It is recommended to use additional imaging before performing surgical exploration. Furthermore, it is important to insert the Implanon NXT according to the supplied instructions to prevent this complication.


Assuntos
Anticoncepcionais Femininos/efeitos adversos , Desogestrel/efeitos adversos , Migração de Dispositivo Intrauterino/efeitos adversos , Dispositivos Intrauterinos Medicados/efeitos adversos , Transtornos do Humor/induzido quimicamente , Adulto , Feminino , Humanos
9.
Ned Tijdschr Geneeskd ; 1642021 01 21.
Artigo em Holandês | MEDLINE | ID: mdl-33651516

RESUMO

A clinical picture of a 35-year-old woman presented at the gynaecology department with a positive pregnancy test even though she had an intra-uterine device (IUD) inserted three months previously. During laparoscopy the Ballerina IUD turns out to be located in the appendix.


Assuntos
Dor Abdominal/etiologia , Apêndice/lesões , Migração de Dispositivo Intrauterino/efeitos adversos , Dispositivos Intrauterinos , Gravidez não Planejada , Adulto , Feminino , Humanos , Laparoscopia , Gravidez
10.
11.
Am J Case Rep ; 22: e929469, 2021 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-33608493

RESUMO

BACKGROUND Intrauterine contraceptive devices (IUCD) are commonly used. Although IUCD use is considered safe, one adverse event is uterine perforation and its migration into surrounding organs. Migrations into the urinary bladder and the intestine have been sometimes reported. We here report a very rare case in which an IUCD migrated into the stomach; gastric endoscopy incidentally revealed the IUCD half embedded and half in the gastric lumen. To our knowledge, this is the second report ever of IUCD migration into the stomach. CASE REPORT A 47-year-old woman with BMI 36.2 visited us as a candidate for an intragastric balloon to reduce her weight. An IUCD was inserted 18 years ago and was not yet removed. Diagnostic gastric endoscopy revealed a foreign body appearing to be an IUCD. Endoscopic removal failed. Computed tomography indicated the presence of an IUCD through the gastric cavity and thus we performed laparoscopic removal of the IUCD with wedge resection of the stomach. A penetrating IUCD was confirmed. CONCLUSIONS A gastric foreign body can be a migrated IUCD. Although rare, we must be aware that IUCDs can migrate into unexpected organs.


Assuntos
Balão Gástrico , Migração de Dispositivo Intrauterino , Dispositivos Intrauterinos , Laparoscopia , Feminino , Humanos , Migração de Dispositivo Intrauterino/efeitos adversos , Dispositivos Intrauterinos/efeitos adversos , Pessoa de Meia-Idade , Estômago/diagnóstico por imagem , Estômago/cirurgia
12.
Eur J Contracept Reprod Health Care ; 26(2): 160-166, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33555216

RESUMO

OBJECTIVE: Intrauterine devices (IUDs) are globally one of the most popular methods of contraception. Uterine perforation is one of the most significant complications of IUD use and commonly occurs at the time of IUD insertion rather than presenting as delayed migration. This paper reports a series of 13 cases of displaced IUDs requiring retrieval by laparoscopy or laparotomy. All the IUDs were copper bearing and most perforations occurred immediately after IUD insertion. CASES: In two patients with sigmoid colon injury and IUD penetration of the appendix, laparoscopic management had failed and laparotomy was necessary owing to severe obliteration of the pelvic cavity. In one patient laparotomy was the preferred surgical approach owing to acute bowel perforation. In the remaining patients, the displaced devices were successfully removed by laparoscopy. CONCLUSION: Uterine perforation and IUD migration to the organs in the abdominopelvic cavity are serious complications of IUD insertion and can be successfully managed by laparoscopy, or by laparotomy in the presence of severe pelvic adhesions or unexpected complications.


Assuntos
Migração de Dispositivo Intrauterino/efeitos adversos , Dispositivos Intrauterinos/efeitos adversos , Perfuração Uterina/etiologia , Adulto , Anticoncepção , Feminino , Humanos , Laparoscopia , Laparotomia , Estudos Retrospectivos , Perfuração Uterina/cirurgia
14.
Arch Gynecol Obstet ; 302(5): 1181-1187, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32748051

RESUMO

OBJECTIVE: Intrauterine devices (IUDs) are the most commonly used method of long-acting reversible contraception. IUD malpositions are described as expulsion, embedding, displacement, and perforation, which may cause contraception failure, organ injury, hemorrhage, and infection. The aim of the study was to evaluate the relationship between displacement and IUD positioning in the uterus, and uterine dimensions as measured using transvaginal ultrasonography. MATERIALS AND METHODS: Three-hundred and eighty-four patients who had TCu380A devices inserted at a tertiary hospital were evaluated at insertion and at 1 month, 3 months, and 6 months after insertion. At the insertion visit, demographic characteristics, history of menorrhagia, dysmenorrhea, previous IUD displacement, and obstetric history were recorded. Transvaginal ultrasonographic measurement of the uterine cavity, uterine length, uterine width, cervix length, cervix width, transverse diameter of the uterine cavity, the distance between the tip of the IUD and the fundus, and endometrium were measured to evaluate IUD displacement. RESULTS: Sixteen of 384 patients had displacement. There were significant differences in times between last pregnancy outcomes and IUD insertion and dysmenorrhea history (p = 0.004 and p = 0.028, respectively). Among TCu380A users, women with 7.5 mm IUD endometrium distances had a higher risk for displacement with a sensitivity of 81% and specificity of 37.5% (AUC: 0.607, 95% CI 0.51-0.70). Women with uterus width less than 41.5 mm were more likely to have displacement with a sensitivity of 53.8% and a specificity of 75% (AUC: 0.673, 95% CI 0.60-0.75). CONCLUSION: IUD endometrium distance and uterus width are important parameters for displacement for TCu380A.


Assuntos
Migração de Dispositivo Intrauterino/etiologia , Dispositivos Intrauterinos de Cobre/efeitos adversos , Dispositivos Intrauterinos/efeitos adversos , Ultrassonografia/métodos , Anormalidades Urogenitais/diagnóstico por imagem , Útero/anormalidades , Útero/diagnóstico por imagem , Adulto , Feminino , Humanos , Expulsão de Dispositivo Intrauterino , Migração de Dispositivo Intrauterino/efeitos adversos , Valor Preditivo dos Testes , Anormalidades Urogenitais/complicações
16.
Afr J Reprod Health ; 24(4): 213-217, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34077085

RESUMO

Intrauterine contraceptive device (IUCD) is among the commonly used contraceptive methods in the world including sub-Saharan Africa but have been associated with a number of complications that although rare, can occur. Uterine perforation is the most serious complication of the IUCD. Surgical management is required in cases with complete uterine perforation, in which the IUCD is partially or completely within the peritoneal cavity. We present a case of a 27year old para 2 woman reporting with mild lower abdominal pains and the absence of IUCD string in the vagina after its insertion following evacuation of the uterus 2 years prior to this study. With the utilization of multiple imaging modalities, an exploratory laparotomy was done to remove the migrated IUCD and repair of the perforated bowel and urinary bladder.


Assuntos
Corpos Estranhos/cirurgia , Migração de Corpo Estranho/cirurgia , Migração de Dispositivo Intrauterino/efeitos adversos , Dispositivos Intrauterinos/efeitos adversos , Perfuração Uterina/diagnóstico por imagem , Adulto , Feminino , Humanos , Laparotomia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia , Perfuração Uterina/etiologia
17.
J Minim Invasive Gynecol ; 27(3): 582, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31374341

RESUMO

OBJECTIVE: To introduce an effective method combining various endoscopes in the treatment of intravesical migrated intrauterine device (IUD). DESIGN: A step-by-step explanation of the surgery using video, approved by the Shengjing Hospital of China Medical University. SETTING: Shengjing Hospital of China Medical University. INTERVENTIONS: A 39-year-old young woman, in whom an IUD was inserted 2 months prior, presented with frequent urination after IUD insertion. Cystoscope and pelvic computed tomography were performed, and the results showed an IUD in the bladder. The migrated IUD was found partly in the uterus and partly in the bladder by hysteroscope and cystoscope. Management of the migrated IUD consists of 4 steps: (1) lysing the adhesion between the bladder and uterus, (2) suturing the bladder and taking the IUD part out of the bladder, (3) removing the IUD part in the uterus, and (4) suturing the bladder again to reinforce it and suturing the uterus. CONCLUSION: The migrated IUD in the bladder was successfully and completely extracted by the method combining various endoscopes; operative time was 56 minutes. In the follow-up period the patient did not report any symptoms of frequency urination. This surgical process has the following characteristics: Preoperative examination should be performed to clarify the ectopic site of the IUD, various endoscopes should be combined for diagnosis and treatment, and endoscopic surgery is an effective treatment method for migrated IUD.


Assuntos
Remoção de Dispositivo/instrumentação , Remoção de Dispositivo/métodos , Endoscópios , Migração de Dispositivo Intrauterino , Bexiga Urinária/cirurgia , Adulto , China , Cistectomia/instrumentação , Cistectomia/métodos , Cistoscópios , Feminino , Humanos , Histeroscópios , Migração de Dispositivo Intrauterino/efeitos adversos , Dispositivos Intrauterinos/efeitos adversos , Bexiga Urinária/diagnóstico por imagem , Útero/diagnóstico por imagem , Útero/cirurgia
19.
BMJ Case Rep ; 12(9)2019 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-31519723

RESUMO

Intrauterine contraceptive device (IUCD) is a common birth control method. It is safe but can be associated with serious complications including migration into the peritoneal cavity and penetration into other intra-abdominal and pelvic viscera; most commonly the rectosigmoid colon. Different retrieval methods including endoscopy, laparoscopy or open abdominal surgery have been described. We report the case of 38-year-old woman who became pregnant shortly after insertion of the IUCD 6 years prior to presentation. She delivered vaginally and 'expulsion' of the device was assumed. Some 4 years later, she had another IUCD inserted and remained asymptomatic till she recently presented with iron-deficiency anaemia. As part of the investigation, diagnostic colonoscopy was performed. Surprisingly, the old IUCD was found penetrating into the midrectum. Uneventful endoscopic removal was performed and she remained well at 3-month follow-up. Migrating IUCD remains asymptomatic and may be discovered accidentally during routine investigation for some other symptoms.


Assuntos
Anemia Ferropriva/etiologia , Migração de Dispositivo Intrauterino/efeitos adversos , Dispositivos Intrauterinos/efeitos adversos , Reto/diagnóstico por imagem , Adulto , Anemia Ferropriva/diagnóstico , Colonoscopia/métodos , Endoscopia/métodos , Feminino , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/cirurgia , Humanos , Achados Incidentais , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA