Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20.346
Filtrar
1.
Invest Ophthalmol Vis Sci ; 65(10): 13, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39110588

RESUMO

Purpose: The purpose of this study was to identify potential drug targets for myopia and explore underlying mechanisms. Methods: Mendelian randomization (MR) was implemented to assess the effect of 2684 pharmacologically targetable genes in the blood and retina on the risk of myopia from a genomewide association study (GWAS) for age-at-onset of spectacle wearing-inferred mean spherical equivalent (MSE; discovery cohort, N = 287,448, European), which was further validated in a GWAS for autorefraction-measured MSE (replication cohort, N = 95,619, European). The reliability of the identified significant potential targets was strengthened by colocalization analysis. Additionally, enrichment analysis, protein-protein interaction network, and molecular docking were performed to explore the functional roles and the druggability of these targets. Results: This systematic drug target identification has unveiled 6 putative genetically causal targets for myopia-CD34, CD55, Wnt3, LCAT, BTN3A1, and TSSK6-each backed by colocalization evidence in adult blood eQTL datasets. Functional analysis found that dopaminergic neuron differentiation, cell adhesion, Wnt signaling pathway, and plasma lipoprotein-associated pathways may be involved in myopia pathogenesis. Finally, drug prediction and molecular docking corroborated the pharmacological value of these targets with LCAT demonstrating the strongest binding affinity. Conclusions: Our study not only opens new avenues for the development of therapeutic interventions for myopia but may also help to understand the underlying mechanisms of myopia.


Assuntos
Estudo de Associação Genômica Ampla , Análise da Randomização Mendeliana , Miopia , Humanos , Miopia/genética , Miopia/metabolismo , Simulação de Acoplamento Molecular , Polimorfismo de Nucleotídeo Único , Predisposição Genética para Doença , Masculino , Feminino , Adulto , Mapas de Interação de Proteínas
2.
Invest Ophthalmol Vis Sci ; 65(10): 21, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39136629

RESUMO

Purpose: Few studies have explored choroidal changes after cessation of myopia control. This study evaluated the choroidal thickness (ChT) and choroidal vascularity index (CVI) during and after discontinuing long-term low-concentration atropine eye drops use for myopia control. Methods: Children with progressive myopia (6-16 years; n = 153) were randomized to receive 0.01% atropine eye drops or a placebo (2:1 ratio) instilled daily over 2 years, followed by a 1-year washout (no eye drop use). Optical coherence tomography imaging of the choroid was conducted at the baseline, 2-year (end of treatment phase), and 3-year (end of washout phase) visits. The main outcome measure was the subfoveal ChT. Secondary measures include the CVI. Results: During the treatment phase, the subfoveal choroids in both treatment and control groups thickened by 12-14 µm (group difference P = 0.56). During the washout phase, the subfoveal choroids in the placebo group continued to thicken by 6.6 µm (95% confidence interval [CI] = 1.7 to 11.6), but those in the atropine group did not change (estimate = -0.04 µm; 95% CI = -3.2 to 3.1). Participants with good axial eye growth control had greater choroidal thickening than the fast-progressors during the treatment phase regardless of the treatment group (P < 0.001), but choroidal thickening in the atropine group's fast-progressors was not sustained after stopping eye drops. CVI decreased in both groups during the treatment phase, but increased in the placebo group after treatment cessation. Conclusions: On average, compared to placebo, 0.01% atropine eye drop treatment did not cause a differential rate of change in ChT during treatment, but abrupt cessation of long-term 0.01% atropine eye drops may disrupt normal choroidal thickening in children.


Assuntos
Atropina , Corioide , Midriáticos , Soluções Oftálmicas , Tomografia de Coerência Óptica , Humanos , Atropina/administração & dosagem , Corioide/patologia , Corioide/diagnóstico por imagem , Corioide/efeitos dos fármacos , Masculino , Feminino , Criança , Adolescente , Midriáticos/administração & dosagem , Miopia/tratamento farmacológico , Miopia/fisiopatologia , Método Duplo-Cego , Seguimentos , Refração Ocular/fisiologia , Miopia Degenerativa/tratamento farmacológico , Miopia Degenerativa/fisiopatologia , Acuidade Visual
3.
JAMA Netw Open ; 7(8): e2424595, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39136948

RESUMO

Importance: Time spent outdoors has been proven effective in preventing myopia, but little is known about the association of outdoor exposure patterns with myopia. Objective: To examine the association of outdoor exposure patterns with myopic shift in children. Design, Setting, and Participants: This 1-year prospective cohort study from December 2017 to December 2018 was a secondary analysis of a cluster-randomized trial (Shanghai Time Outside to Reduce Myopia [STORM]). STORM was a school-based intervention study, recruiting 16 schools from 8 districts in Shanghai, from October 2016 to December 2018. Children without myopia at baseline who consistently wore a smartwatch for a minimum of 6 hours daily, sustained for at least 90 days, and who had complete information were included. Data analysis was performed from December 2017 to December 2018. Exposures: The outdoor exposure pattern was defined as the episode of time outdoors and instant sunlight intensity over a continuous period. Main Outcomes and Measures: Myopic shift was defined as the absolute change in refraction between the initial spherical equivalence and the follow-up spherical equivalence. Results: This study included 2976 students (mean [SD] age, 7.2 [0.6] years; 1525 girls [51.2%]). The mean (SD) daily time outdoors was 90 (28) minutes, and the mean (SD) sunlight intensity was 2345 (486) lux. Of the 12 outdoor exposure patterns, the major outdoor exposure patterns were time outdoors with at least 15 minutes, accounting for 74.9% of minutes (33 677 584 of 45 016 800 minutes). Only patterns with at least 15 minutes accompanied with no less than 2000 lux were associated with less myopic shift in refraction (for ≥15 minutes and 2000 to 3999 lux, -0.007 diopter [D] [95% CI, -0.011 to -0.002 D]; for ≥15 minutes and ≥4000 lux, -0.006 D [95% CI, -0.010 to -0.002 D]). The isotemporal substitution of patterns with at least 15 minutes and 2000 lux for other outdoor exposure patterns was positively associated with less myopic shift. Conclusions and Relevance: In this 1-year prospective cohort study of children with smartwatches, continuous outdoor exposure with at least 15 minutes accompanied with no less than 2000 lux sunlight intensity was associated with less myopic shift. These findings suggest that future outdoor interventions should focus not only on the overall time outdoors but also on the effective outdoor exposure patterns, as a means to effectively prevent myopia in children.


Assuntos
Miopia , Humanos , Miopia/prevenção & controle , Miopia/epidemiologia , Criança , Feminino , Masculino , Estudos Prospectivos , China/epidemiologia , Exposição Ambiental , Luz Solar , Dispositivos Eletrônicos Vestíveis , Refração Ocular/fisiologia
4.
Int Ophthalmol ; 44(1): 349, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39147902

RESUMO

PURPOSE: This retrospective study investigated the impact of corneal parameters on surgically induced astigmatism (SIA) in eyes with prior myopic correction undergoing cataract surgery. SETTING: Department of Ophthalmology, San Marino Hospital, San Marino, Republic of San Marino. DESIGN: This case-control study analyzed existing data retrospectively, without randomization or masking. METHODS: Eighty eyes divided in group 1 (40 eyes previous underwent refractive surgery for myopia) and group 2 ( 40 myopic eyes) that underwent cataract surgery with intraocular lens (IOL) implantation were included. SIA was calculated using values from the IOL Master Zeiss 700 and mean pupil power (MPP) derived from the CSO Sirius Topographer (based on 3 mm pupil size) with vectorial analysis from doctor Hill software. RESULTS: No significant difference in SIA was observed between eyes with prior myopic photorefractive keratectomy and the control group (p > 0.05). SIA calculations using the IOL Master and CSO Sirius Tomographer yielded similar results. There was no significant correlation between SIA and axial length, corneal curvature, peripheral corneal thickness, or anterior chamber depth (p > 0.05). However, an inverse correlation was found between SIA and horizontal corneal diameter (p < 0.05). CONCLUSIONS: Corneal parameters, such as axial length, corneal curvature, peripheral corneal thickness, and anterior chamber depth, showed no significant influence on SIA. The inverse correlation between SIA and horizontal corneal diameter in study group suggests potential influence of white-to-white distance on SIA. These findings highlight the importance of considering corneal parameters for optimizing surgical outcomes.


Assuntos
Astigmatismo , Córnea , Topografia da Córnea , Miopia , Humanos , Astigmatismo/etiologia , Astigmatismo/fisiopatologia , Astigmatismo/diagnóstico , Estudos Retrospectivos , Masculino , Feminino , Miopia/cirurgia , Miopia/fisiopatologia , Córnea/patologia , Córnea/cirurgia , Córnea/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos de Casos e Controles , Topografia da Córnea/métodos , Idoso , Extração de Catarata/efeitos adversos , Acuidade Visual , Implante de Lente Intraocular/efeitos adversos , Refração Ocular/fisiologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Facoemulsificação/efeitos adversos
5.
J Glaucoma ; 33(8): e64-e75, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39141409

RESUMO

Intraocular pressure is currently the only known reliable, modifiable risk factor for the development and progression of glaucoma. Other risk factors for glaucoma include increasing age, myopia, decreased central corneal thickness, and low corneal hysteresis (CH) measurements. Photoablative keratorefractive surgery including laser assisted in situ keratomileusis (LASIK) has become a common way to treat refractive error, with over 25 million procedures performed in the United States alone. Though myopic LASIK has been associated with a decrease in CH measurements, relatively little is known about the risk of LASIK on glaucoma onset and progression. Here we present an observational study of 4 consecutive relatively young and otherwise healthy glaucoma patients with a history of myopic LASIK who showed progression of paracentral visual field deficits at intraocular pressures of 12 mm Hg or less while being carefully monitored. Therefore, these patients required lower targets of intraocular pressure, in the single-digit range, to slow or halt progression. In this cohort, the average corneal hysteresis was more than 2 standard deviations below normal values. This series suggests that additional study into the association of LASIK and glaucoma is warranted, including the potential risk contribution of diminished CH. These studies may be particularly relevant as patients who underwent LASIK procedures in the early 2000s may now be at increased risk of glaucoma due to the risk factor of age.


Assuntos
Progressão da Doença , Pressão Intraocular , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Tonometria Ocular , Campos Visuais , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Pressão Intraocular/fisiologia , Campos Visuais/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Masculino , Feminino , Adulto , Córnea/fisiopatologia , Transtornos da Visão/fisiopatologia , Transtornos da Visão/etiologia , Transtornos da Visão/diagnóstico , Testes de Campo Visual , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Fatores de Risco , Lasers de Excimer/uso terapêutico , Adulto Jovem
6.
BMC Ophthalmol ; 24(1): 349, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39152392

RESUMO

BACKGROUND: Accurate prediction of postoperative vault in implantable collamer lens (ICL) implantation is crucial; however, current formulas often fail to account for individual anatomical variations, leading to suboptimal visual outcomes and necessitating improved predictive models. We aimed to verify the prediction accuracy of our new predictive model for vaulting based on anterior and posterior chamber structural parameters. METHODS: This retrospective observational study included 137 patients (240 eyes) who previously underwent ICL surgery. Patients were randomly divided into the model establishment (192 eyes) or validation (48 eyes) groups. Preoperative measurements of the anterior and posterior chamber structures were obtained using Pentacam, CASIA2 anterior segment optical coherence tomography (AS-OCT), ultrasound biomicroscopy, and other devices. Stepwise multiple linear regression analysis was used to evaluate the relationship between the vault and each variable (WL formula). The Friedman test was performed for the vaulting prediction results of the WL, NK (Ver. 3), and KS formulas (Ver. 4) in CASIA2 AS-OCT, as well as the Zhu formula and vault measurements. The proportions of prediction error within ± 250 µm per formula were compared. RESULTS: The predicted vault values of the WL, NK, KS, and Zhu formulas and vault measurements were 668.74 ± 162.12, 650.85 ± 248.47, 546.56 ± 128.99, 486.56 ± 210.76, and 716.06 ± 233.84 µm, respectively, with a significant difference (χ2 = 69.883, P = 0.000). Significant differences were also found between the measured vault value and Zhu formula, measured vault value and KS formula, WL formula and Zhu formula, WL formula and KS formula, NK formula and KS formula, and NK formula and Zhu formula (P < 0.001) but not between other groups. The proportions of prediction error within ± 250 µm per formula were as follows: WL formula (81.3%) > NK formula (70.8%) > KS formula (66.7%) > Zhu formula (54.2%). CONCLUSIONS: The WL formula, which considers the complexity of the anterior and posterior chamber structures, demonstrates greater calculation accuracy, compared with the KS (Ver. 4) and Zhu formulas. The proportion of absolute prediction error ≤ 250 µm is higher with the WL formula than with the NK formula (ver. 3). This enhanced predictive capability can improve ICL sizing decisions, thereby increasing the safety and efficacy of ICL implantation surgeries.


Assuntos
Implante de Lente Intraocular , Tomografia de Coerência Óptica , Humanos , Estudos Retrospectivos , Feminino , Masculino , Tomografia de Coerência Óptica/métodos , Adulto , Implante de Lente Intraocular/métodos , Câmara Anterior/diagnóstico por imagem , Lentes Intraoculares Fácicas , Miopia/cirurgia , Microscopia Acústica/métodos , Adulto Jovem , Pessoa de Meia-Idade , Acuidade Visual , Biometria/métodos , Refração Ocular/fisiologia
8.
Arq Bras Oftalmol ; 87(5): e20230009, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39109702

RESUMO

This document on myopia control is derived from a compilation of medical literature and the collective clinical expertise of an expert committee comprising members from the Brazilian Society of Pediatric Ophthalmology and the Brazilian Society of Contact Lenses and Cornea. To manage myopia in children, the committee recommends corneal topography and biannual visits with cycloplegic refraction, along with annual optical biometry. For fast-progressing myopia, biannual biometry should be considered. Myopic progression is defined as an annual increase in spherical equivalent greater than 0.50 D/year or in axial length greater than 0.3 mm (until 10 years old) or 0.2 mm (above 11 years). The proposed treatments for myopia progression include environmental control, low concentration atropine, defocus glasses, contact lenses, or Ortho-K lenses, and combinations of these methods may be necessary for uncontrolled cases. Treatment should be sustained for at least 2 years. This document serves as a comprehensive guideline for diagnosing, treating, and monitoring pre-myopic and myopic children in Brazil.


Assuntos
Progressão da Doença , Miopia , Humanos , Criança , Miopia/prevenção & controle , Miopia/terapia , Brasil , Refração Ocular/fisiologia , Topografia da Córnea/métodos , Biometria/métodos
9.
Transl Vis Sci Technol ; 13(8): 16, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39120886

RESUMO

Purpose: To develop and validate machine learning (ML) models for predicting cycloplegic refractive error and myopia status using noncycloplegic refractive error and biometric data. Methods: Cross-sectional study of children aged five to 18 years who underwent biometry and autorefraction before and after cycloplegia. Myopia was defined as cycloplegic spherical equivalent refraction (SER) ≤-0.5 Diopter (D). Models were evaluated for predicting SER using R2 and mean absolute error (MAE) and myopia status using area under the receiver operating characteristic (ROC) curve (AUC). Best-performing models were further evaluated using sensitivity/specificity and comparison of observed versus predicted myopia prevalence rate overall and in each age group. Independent data sets were used for training (n = 1938) and validation (n = 1476). Results: In the validation dataset, ML models predicted cycloplegic SER with high R2 (0.913-0.935) and low MAE (0.393-0.480 D). The AUC for predicting myopia was high (0.984-0.987). The best-performing model for SER (XGBoost) had high sensitivity and specificity (91.1% and 97.2%). Random forest (RF), the best-performing model for myopia, had high sensitivity and specificity (92.2% and 96.9%). Within each age group, difference between predicted and actual myopia prevalence was within 4%. Conclusions: Using noncycloplegic refractive error and ocular biometric data, ML models performed well for predicting cycloplegic SER and myopia status. When measuring cycloplegic SER is not feasible, ML may provide a useful tool for estimating cycloplegic SER and myopia prevalence rate in epidemiological studies. Translational Relevance: Using ML to predict cycloplegic refraction based on noncycloplegic data is a powerful tool for large, population-based studies of refractive error.


Assuntos
Aprendizado de Máquina , Midriáticos , Miopia , Refração Ocular , Humanos , Criança , Estudos Transversais , Masculino , Feminino , Miopia/epidemiologia , Miopia/diagnóstico , Adolescente , Pré-Escolar , Midriáticos/administração & dosagem , Refração Ocular/fisiologia , China/epidemiologia , Biometria/métodos , Erros de Refração/epidemiologia , Erros de Refração/diagnóstico , Curva ROC , Prevalência , Área Sob a Curva , Estudantes , População do Leste Asiático
10.
Medicine (Baltimore) ; 103(32): e37878, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39121247

RESUMO

To investigate the etiologies and clinical characteristics of full-thickness macular hole (FTMH) cases at Shanxi Eye Hospital in North China. Patients diagnosed with FTMH who underwent surgery from 2012 to 2020 were included, and the etiologies and clinical features of MH types were analyzed in an 8-year, cross-sectional, retrospective study. A total of 752 cases (776 eyes) were analyzed. The top 3 subtypes of MH were idiopathic (IMH, 64.4%), myopic (MMH, 21.1%) and traumatic (TMH, 3.7%) MH. Among these, there were significant differences in sex, age, and baseline best-corrected visual acuity (BCVA) distributions. Females predominated in the IMH and MMH groups, while males predominated in the TMH group. The IMH onset age was older than the MMH and TMH onset ages. Baseline BCVA in the IMH (Z = 8.9, P < .001) and the other group (Z = 4.0, P < .001) was significantly better than that in the MMH group. In the IMH group, females were younger, had a shorter axial length (AL), and had a worse baseline BCVA than males, while in the MMH group, there were no significant sex differences. Multivariate correlation analysis showed that a smaller hole diameter in IMH, no retinal detachment in MMH, and a younger age in TMH may result in better baseline BCVA. The most common MH etiologies were IMH, MMH and TMH, which contributed to differences in clinical features. Females predominated in the IMH and MMH groups, and the onset of MMH occurred 6.5 years earlier than the onset of IMH. Therefore, early fundus monitoring in females and high myopia patients is helpful for the early detection and treatment of MH.


Assuntos
Perfurações Retinianas , Acuidade Visual , Humanos , Perfurações Retinianas/etiologia , Perfurações Retinianas/cirurgia , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Estudos Transversais , Idoso , China/epidemiologia , Adulto , Fatores Sexuais , Fatores Etários , Miopia/complicações
11.
BMC Ophthalmol ; 24(1): 325, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39103855

RESUMO

BACKGROUND: To analyze the clinical outcomes after topography-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) with Phorcides Analytic Engine (PAE) algorithm or Custom-Q FS-LASIK for myopia with nonastigmatic eyes. METHODS: In this retrospective study, a total of 90 eyes with myopia without manifest astigmatism (82 patients) were included. All surgeries were performed by topography-guided FS-LASIK planned with a PAE algorithm (42 eyes) or Custom-Q system (48 eyes). Refractive, visual outcomes and corneal aberrations were compared between the two groups. RESULTS: At 6 months postoperatively, the postoperative uncorrected distance visual acuity (UDVA) was 20/20 or better in 42 eyes (100%) in the PAE compared with 44 eyes (92%) in Custom-Q (P = .120). The postoperative UDVA of 20/16 or better was measured in 92% of eyes in the PAE group and 81% of eyes in the Custom Q group (P = .320). Postoperative corrected distance visual acuity, manifest refractive spherical equivalent and refractive astigmatism were similar between the two groups (P > .05). The postoperative optical path difference (OPD) and Strehl ratio (SR) were significantly better in the PAE group compared with the Custom Q group. CONCLUSIONS: Topography-guided FS-LASIK with PAE algorithm or Custom Q demonstrated similar refractive efficacy and predictability. PAE for the patients with zero manifest astigmatism demonstrated better results in correcting corneal aberrations.


Assuntos
Topografia da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Estudos Retrospectivos , Acuidade Visual/fisiologia , Masculino , Feminino , Miopia/cirurgia , Miopia/fisiopatologia , Adulto , Refração Ocular/fisiologia , Lasers de Excimer/uso terapêutico , Adulto Jovem , Resultado do Tratamento , Cirurgia Assistida por Computador/métodos
12.
Nat Commun ; 15(1): 6703, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39112444

RESUMO

Extreme myopia (EM), defined as a spherical equivalent (SE) ≤ -10.00 diopters (D), is one of the leading causes of sight impairment. Known EM-associated variants only explain limited risk and are inadequate for clinical decision-making. To discover risk genes, we performed a whole-exome sequencing (WES) on 449 EM individuals and 9606 controls. We find a significant excess of rare protein-truncating variants (PTVs) in EM cases, enriched in the retrograde vesicle-mediated transport pathway. Employing single-cell RNA-sequencing (scRNA-seq) and a single-cell polygenic burden score (scPBS), we pinpointed PI16 + /SFRP4+ fibroblasts as the most relevant cell type. We observed that KDELR3 is highly expressed in scleral fibroblast and involved in scleral extracellular matrix (ECM) organization. The zebrafish model revealed that kdelr3 downregulation leads to elongated ocular axial length and increased lens diameter. Together, our study provides insight into the genetics of EM in humans and highlights KDELR3's role in EM pathogenesis.


Assuntos
Sequenciamento do Exoma , Mutação , Peixe-Zebra , Humanos , Animais , Peixe-Zebra/genética , Masculino , Feminino , Fibroblastos/metabolismo , Exoma/genética , Estudo de Associação Genômica Ampla , Adulto , Miopia/genética , Miopia/metabolismo , Miopia/patologia , Esclera/metabolismo , Esclera/patologia , Matriz Extracelular/metabolismo , Matriz Extracelular/genética , Predisposição Genética para Doença , Análise de Célula Única , Estudos de Casos e Controles , Criança , Adulto Jovem
13.
BMC Ophthalmol ; 24(1): 329, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39112923

RESUMO

BACKGROUND: Considering that changes in the choroidal thickness are closely related to ocular growth, we studied the choroidal thickness (CT) and the blood flow features in children with unilateral myopic anisometropia (UMA) as well as investigating the relationship between choroidal changes and myopia. METHODS: Subjective refractive, axial length (AL), and biometric parameters were measured in 98 UMA children (age: 8-15 years). CT and choroidal blood-flow features, including the choroidal vessel volume (CVV), choroidal vascularity index (CVI), and choriocapillaris perfusion area (CCPA), were measured through swept-source optical coherence tomography angiography. The macular region was categorized into four concentric circles of diameters 0-1 mm (central fovea), 1-3 mm (parafovea), 3-6 mm (perifovea), and 6-9 mm (extended), and further categorized into superior (S), inferior (I), temporal (T), and nasal (N) quadrants. RESULTS: The aforementioned four regions of myopic eyes displayed significantly lower CT, CVV, and CVI than those of non-myopic eyes. CCPA changes differed across different regions of both the eyes (parts of N and T quadrants). There was an inverse association between CT and the interocular AL difference (central and other regions S, T quadrant). No correlation was noted between CVV and CVI with interocular AL difference. CT and CVV were positively correlated in the 0-6-mm macular region of myopic eyes (Spearman correlation coefficient = 0.763, P < 0.001). CONCLUSIONS: In UMA children, CCT and blood flow may be related to myopia progression. A robust correlation between CT and CVV in the 0-6-mm macular region and reduced CT and diminished blood flow indicated an association with myopia.


Assuntos
Anisometropia , Comprimento Axial do Olho , Corioide , Miopia , Fluxo Sanguíneo Regional , Tomografia de Coerência Óptica , Humanos , Corioide/irrigação sanguínea , Corioide/patologia , Corioide/diagnóstico por imagem , Criança , Adolescente , Masculino , Feminino , Anisometropia/fisiopatologia , Miopia/fisiopatologia , Tomografia de Coerência Óptica/métodos , Comprimento Axial do Olho/patologia , Fluxo Sanguíneo Regional/fisiologia , Refração Ocular/fisiologia , Angiofluoresceinografia/métodos
14.
Transl Vis Sci Technol ; 13(8): 4, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39093295

RESUMO

Purpose: This study aims to investigate the impact of axial elongation on ganglion cell complex thickness (GCCT) and retinal capillary density (CD) using wide-field swept-source optical coherence tomography angiography. Methods: A retrospective cross-sectional analysis was conducted involving 506 eyes. Fovea-centered scans were obtained to assess the subregional GCCT and capillary density across the whole retina, the superficial capillary plexus (SCP), and deep capillary plexus (DCP) among three groups: normal control, high myopia (HM) eyes with axial length < 28 mm, and HM eyes with axial length > 28 mm. Regional variations (central vs. peripheral, quadrants difference [superior, inferior, nasal, and temporal]) were analyzed. Results: In HM eyes with axial length > 28 mm, GCCT and retinal CD exhibit a general decline in most regions (P < 0.05). In HM eyes with axial length < 28 mm, significant reductions were observed specifically in peripheral regions, as in the GCCT beyond the 3 × 3 mm2 area and CD in the 9-12 mm whole retina, 9-12 mm superior SCP, and 6-12 mm DCP (P < 0.05). Maximum GCCT and retinal CD reduction with axial elongation was observed in subregions beyond 6 × 6  mm2. Conclusions: GCCT beyond the 3 × 3 mm2 area and peripheral retinal CD beyond the 6 × 6  mm2 area were more susceptible to axial elongation and are thereby deserving of particular attention. Translational Relevance: It is necessary to evaluate different regions during the clinical assessment of the effect of myopia on the fundus and pay close attention to the peripheral retina.


Assuntos
Células Ganglionares da Retina , Vasos Retinianos , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Estudos Retrospectivos , Masculino , Células Ganglionares da Retina/patologia , Feminino , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Pessoa de Meia-Idade , Adulto , Miopia/patologia , Miopia/diagnóstico por imagem , Miopia/fisiopatologia , Microvasos/patologia , Microvasos/diagnóstico por imagem , Comprimento Axial do Olho/patologia , Comprimento Axial do Olho/diagnóstico por imagem , Fibras Nervosas/patologia , Angiofluoresceinografia/métodos , Adulto Jovem , Idoso , Capilares/patologia , Capilares/diagnóstico por imagem
15.
Optom Vis Sci ; 101(7): 470-476, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39094022

RESUMO

SIGNIFICANCE: This study explores the difference between cycloplegic and noncycloplegic refraction in young adult myopes. PURPOSE: From the available literature, it is unclear whether cycloplegia is necessary when refracting young adults. This study investigates the agreement between noncycloplegic autorefraction and cycloplegic autorefraction and investigates factors affecting the agreement between the two methods. METHODS: In total, 125 myopes with ages ranging between 18 and 26 years were included from Australia and Vietnam. Each participant underwent noncycloplegic autorefraction and cycloplegic autorefraction. Cycloplegia was induced with 1% ophthalmic tropicamide. RESULTS: The mean spherical equivalent difference (95% confidence interval) between noncycloplegic autorefraction and cycloplegic autorefraction was -0.20 D (-0.25 to -0.14 D; t124 = -7.18, p<0.0001 ) . A mean difference of >0.25 D was seen in 46.8% of eyes. The lower and upper limits of agreement were -0.80 and 0.41 D, respectively. With univariate analysis, factors including age, degree of refractive error, accommodation amplitude, and distance phorias showed no impact on the average difference between cycloplegic autorefraction and noncycloplegic autorefraction. Yet, eyes with near exophoria ( F2,120 = 6.63, p=0.0019) and Caucasian eyes ( F3,121 = 2.85, p=0.040) exhibited the smallest paired differences. However, in the multivariate analysis, only near exophoria was associated with a lower mean difference. A significantly smaller proportion (34.9%) of eyes with near exophoria had a paired difference of -0.25 D or more compared with esophoria (50%) and orthophoria (65%; χ2 = 6.6, p=0.038). CONCLUSIONS: Noncycloplegic autorefraction results in more myopic refractive error than cycloplegic autorefraction in young adults.


Assuntos
Midriáticos , Miopia , Refração Ocular , Tropicamida , Humanos , Refração Ocular/fisiologia , Adulto Jovem , Midriáticos/administração & dosagem , Adulto , Masculino , Adolescente , Feminino , Miopia/fisiopatologia , Miopia/diagnóstico , Tropicamida/administração & dosagem , Pupila/efeitos dos fármacos , Pupila/fisiologia , Acomodação Ocular/fisiologia
16.
JAMA Netw Open ; 7(8): e2425124, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39106068

RESUMO

IMPORTANCE: Identifying pediatric eye diseases at an early stage is a worldwide issue. Traditional screening procedures depend on hospitals and ophthalmologists, which are expensive and time-consuming. Using artificial intelligence (AI) to assess children's eye conditions from mobile photographs could facilitate convenient and early identification of eye disorders in a home setting. OBJECTIVE: To develop an AI model to identify myopia, strabismus, and ptosis using mobile photographs. DESIGN, SETTING, AND PARTICIPANTS: This cross-sectional study was conducted at the Department of Ophthalmology of Shanghai Ninth People's Hospital from October 1, 2022, to September 30, 2023, and included children who were diagnosed with myopia, strabismus, or ptosis. MAIN OUTCOMES AND MEASURES: A deep learning-based model was developed to identify myopia, strabismus, and ptosis. The performance of the model was assessed using sensitivity, specificity, accuracy, the area under the curve (AUC), positive predictive values (PPV), negative predictive values (NPV), positive likelihood ratios (P-LR), negative likelihood ratios (N-LR), and the F1-score. GradCAM++ was utilized to visually and analytically assess the impact of each region on the model. A sex subgroup analysis and an age subgroup analysis were performed to validate the model's generalizability. RESULTS: A total of 1419 images obtained from 476 patients (225 female [47.27%]; 299 [62.82%] aged between 6 and 12 years) were used to build the model. Among them, 946 monocular images were used to identify myopia and ptosis, and 473 binocular images were used to identify strabismus. The model demonstrated good sensitivity in detecting myopia (0.84 [95% CI, 0.82-0.87]), strabismus (0.73 [95% CI, 0.70-0.77]), and ptosis (0.85 [95% CI, 0.82-0.87]). The model showed comparable performance in identifying eye disorders in both female and male children during sex subgroup analysis. There were differences in identifying eye disorders among different age subgroups. CONCLUSIONS AND RELEVANCE: In this cross-sectional study, the AI model demonstrated strong performance in accurately identifying myopia, strabismus, and ptosis using only smartphone images. These results suggest that such a model could facilitate the early detection of pediatric eye diseases in a convenient manner at home.


Assuntos
Inteligência Artificial , Diagnóstico Precoce , Fotografação , Humanos , Feminino , Masculino , Estudos Transversais , Criança , Pré-Escolar , Fotografação/métodos , Miopia/diagnóstico , Aprendizado Profundo , Estrabismo/diagnóstico , Blefaroptose/diagnóstico , Sensibilidade e Especificidade , China/epidemiologia , Oftalmopatias/diagnóstico , Adolescente
17.
BMC Ophthalmol ; 24(1): 355, 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39164617

RESUMO

BACKGROUND: To assess the relationship between postoperative implantable collamer lens (ICL) vault and lens height obtained from two different measurements. METHODS: A retrospective case series study enrolled eyes with horizontally implanted ICL. Crystal lens rise (CLR) and the distance between STS plane and anterior crystalline lens surface (STSL) were measured in the horizontal and vertical directions using ultrasound biomicroscopy (UBM). We compared the differences in the parameters measured in both horizontal and vertical directions. The participants were categorized into three groups according to ciliary sulcus width (CSW) which is defined as the distance between the posterior angle of the iris and the anterior angle of the ciliary process: narrow CSW group (NSG); medium CSW group (MSG); and wide CSW group (WSG). The correlations between CLR/STSL and vault were examined in each of the three groups. Biased correlation analysis was used further to contrast the correlation between CLR/STSL and vault. RESULTS: This retrospective study included 223 myopic eyes. Vertical STSL (VSTSL) and vertical CLR (VCLR) exhibited significantly greater values compared to their horizontal counterparts (both P < 0.05). None of the indicators were statistically different between the three groups. In both NSG and MSG, STSL/CLR correlated with vault, while in WSG, only STSL correlated with vault (r=-0.316, P = 0.013). In contrast to HCLR, the correlation between HSTSL and vault remained after controlling for HCLR (r=-0.162, P = 0.015). CONCLUSIONS: STSL should deserve more attention in the preoperative evaluation of ICL compared to CLR especially when CSW is large.


Assuntos
Corpo Ciliar , Implante de Lente Intraocular , Microscopia Acústica , Miopia , Lentes Intraoculares Fácicas , Humanos , Estudos Retrospectivos , Masculino , Feminino , Corpo Ciliar/diagnóstico por imagem , Corpo Ciliar/patologia , Projetos Piloto , Adulto , Miopia/cirurgia , Miopia/fisiopatologia , Cristalino/diagnóstico por imagem , Adulto Jovem , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Refração Ocular/fisiologia
18.
BMC Ophthalmol ; 24(1): 321, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39090603

RESUMO

BACKGROUND: Assessing refractive errors under cycloplegia is recommended for paediatric patients; however, this may not always be feasible. In these situations, refraction has to rely on measurements made under active accommodation which may increase measurements variability and error. Therefore, evaluating the accuracy and precision of non-cycloplegic refraction and biometric measurements is clinically relevant. The Myopia Master, a novel instrument combining autorefraction and biometry, is designed for monitoring refractive error and ocular biometry in myopia management. This study assessed its repeatability and agreement for autorefraction and biometric measurements pre- and post-cycloplegia. METHODS: A prospective cross-sectional study evaluated a cohort of 96 paediatric patients that underwent ophthalmologic examination. An optometrist performed two repeated measurements of autorefraction and biometry pre- and post-cycloplegia. Test-retest repeatability (TRT) was assessed as differences between consecutive measurements and agreement as differences between post- and pre-cycloplegia measurements, for spherical equivalent (SE), refractive and keratometric J0/J45 astigmatic components, mean keratometry (Km) and axial length (AL). RESULTS: Cycloplegia significantly improved the SE repeatability (TRT, pre-cyclo: 0.65 D, post-cyclo: 0.31 D). SE measurements were more repeatable in myopes and emmetropes compared to hyperopes. Keratometry (Km) repeatability did not change with cycloplegia (TRT, pre-cyclo: 0.25 D, post-cyclo:0.27 D) and AL repeatability improved marginally (TRT, pre-cyclo: 0.14 mm, post-cyclo: 0.09 mm). Regarding pre- and post-cycloplegia agreement, SE became more positive by + 0.79 D, varying with refractive error. Myopic eyes showed a mean difference of + 0.31 D, while hyperopes differed by + 1.57 D. Mean keratometry, refractive and keratometric J0/J45 and AL showed no clinically significant differences. CONCLUSIONS: Refractive error measurements, using the Myopia Master were 2.5x less precise pre-cycloplegia than post-cycloplegia. Accuracy of pre-cycloplegic refractive error measurements was often larger than the clinically significant threshold (0.25 D) and was refractive error dependent. The higher precision compared to autorefraction measurements, pre- and post-cycloplegia agreement and refractive error independence of AL measurements emphasize the superiority of AL in refractive error monitoring.


Assuntos
Comprimento Axial do Olho , Biometria , Midriáticos , Miopia , Refração Ocular , Humanos , Estudos Prospectivos , Estudos Transversais , Feminino , Masculino , Refração Ocular/fisiologia , Midriáticos/administração & dosagem , Criança , Miopia/fisiopatologia , Biometria/métodos , Adolescente , Reprodutibilidade dos Testes , Pupila/efeitos dos fármacos , Pupila/fisiologia , Córnea/patologia , Córnea/fisiopatologia
19.
BMC Ophthalmol ; 24(1): 351, 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39155380

RESUMO

PURPOSE: To investigate the repeatability and reproducibility of a new method for centration analysis after small incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK (FS-LASIK). METHODS: This study comprised 29 eyes treated with SMILE and 24 with FS-LASIK. Decentrations were analyzed using tangential and pachymetry difference maps respectively. Both difference maps were generated with a Scheimpflug tomographer (Pentacam) for each eye, using preoperative and 3-month postoperative scans. Repeatability and reproducibility were evaluated by calculating the intraclass correlation coefficient (ICC), within-subject standard deviation (Sw), and coefficient of repeatability (CR). RESULTS: ICC, Sw, and CR showed good to excellent repeatability in locating the coordinates of the optical zone (OZ) center on both maps, with values ranging from 0.84 to 0.96, 0.03 to 0.13, and 0.08 to 0.36 respectively. The repeatability of the total decentration from the preoperative corneal vertex on the tangential curvature difference maps( d TC ) and the pachymetry difference maps( d PC ) were moderate and good, respectively. The ICC, Sw, and CR of d TC were 0.63, 0.09, and 0.25, respectively. The ICC, Sw, and CR of d PC were 0.77, 0.10, and 0.28, respectively. The reproducibility of the OZ center measurements was excellent for the tangential difference maps (ICC ≥ 0.97 ) and good for the pachymetry difference maps (ICC ≥ 0.86). ICC, Sw, and CR showed excellent reproducibility of d TC , with values of 0.95, 0.03, and 0.08, respectively. ICC, Sw, and CR showed good reproducibility of d PC , with values of 0.89, 0.06, and 0.17, respectively. CONCLUSION: The centration analysis method used in this study showed good to excellent repeatability and reproducibility in locating the coordinates of the center of the OZ on the tangential and pachymetry difference maps.


Assuntos
Córnea , Topografia da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Refração Ocular , Humanos , Reprodutibilidade dos Testes , Feminino , Adulto , Masculino , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Miopia/cirurgia , Adulto Jovem , Córnea/cirurgia , Córnea/diagnóstico por imagem , Córnea/patologia , Refração Ocular/fisiologia , Topografia da Córnea/métodos , Paquimetria Corneana/métodos , Lasers de Excimer/uso terapêutico , Acuidade Visual , Cirurgia da Córnea a Laser/métodos , Pessoa de Meia-Idade , Período Pós-Operatório
20.
J Glaucoma ; 33(Suppl 1): S45-S48, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39149950

RESUMO

PRCIS: A large disk, a large parapapillary delta zone and a long axial length may be used as screening criteria to detect glaucomatous optic neuropathy in highly myopic eyes. PURPOSE: To describe aspects for screening of glaucomatous optic neuropathy in dependence of refractive error, under special consideration of high myopia. METHODS/RESULTS: Studies on the anatomy of the myopic optic nerve head and results of investigations on the relationship between glaucomatous optic neuropathy and axial myopia were included. CONCLUSIONS: In the range from hyperopia to moderate myopia, refractive error is not a strong glaucoma risk factor and may not be included in glaucoma screening strategies. Care should be taken, that in moderate myopia, a shift of Bruch´s membrane opening usually into the temporal direction leads to parapapillary gamma zone and a corresponding shortening of the horizontal disk diameter. In these moderately myopic eyes, a secondarily small optic disk with a correspondingly small optic cup should not lead to an overlooking of intrapapillary glaucomatous changes. Prevalence of glaucomatous or glaucoma-like optic nerve atrophy (GOA) steeply increases with longer axial length in highly myopic eyes (cutoff approximately -8 diopters/axial length 26.5 mm), with prevalences higher than 50% in extremely high myopia. Besides longer axial length, morphological parameters associated with GOA in highly myopic eyes are a secondarily enlarged disk and large parapapillary delta zone. Both parameters, together with long axial length, may be used as screening criteria in high myopia for GOA. The latter is characterized by an abnormal neuroretinal rim shape, that is, vessel kinking close to the intrapapillary disk border. Factors associated with nonglaucomatous optic neuropathy are larger gamma zone and longer axial length, potentially due to an axial elongation-related retinal nerve fiber stretching.


Assuntos
Miopia , Disco Óptico , Humanos , Disco Óptico/patologia , Disco Óptico/diagnóstico por imagem , Miopia/diagnóstico , Miopia/complicações , Glaucoma/diagnóstico , Glaucoma/complicações , Comprimento Axial do Olho/patologia , Doenças do Nervo Óptico/diagnóstico , Erros de Refração/diagnóstico , Pressão Intraocular/fisiologia , Fatores de Risco , Atrofia Óptica/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA