Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 11.777
Filtrar
1.
Crit Care Explor ; 6(5): e1089, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38728059

RESUMO

IMPORTANCE: Patients admitted with cerebral hemorrhage or cerebral edema often undergo external ventricular drain (EVD) placement to monitor and manage intracranial pressure (ICP). A strain gauge transducer accompanies the EVD to convert a pressure signal to an electrical waveform and assign a numeric value to the ICP. OBJECTIVES: This study explored ICP accuracy in the presence of blood and other viscous fluid contaminates in the transducer. DESIGN: Preclinical comparative design study. SETTING: Laboratory setting using two Natus EVDs, two strain gauge transducers, and a sealed pressure chamber. PARTICIPANTS: No human subjects or animal models were used. INTERVENTIONS: A control transducer primed with saline was compared with an investigational transducer primed with blood or with saline/glycerol mixtures in mass:mass ratios of 25%, 50%, 75%, and 100% glycerol. Volume in a sealed chamber was manipulated to reflect changes in ICP to explore the impact of contaminates on pressure measurement. MEASUREMENTS AND MAIN RESULTS: From 90 paired observations, ICP readings were statistically significantly different between the control (saline) and experimental (glycerol or blood) transducers. The time to a stable pressure reading was significantly different for saline vs. 25% glycerol (< 0.0005), 50% glycerol (< 0.005), 75% glycerol (< 0.0001), 100% glycerol (< 0.0005), and blood (< 0.0005). A difference in resting stable pressure was observed for saline vs. blood primed transducers (0.041). CONCLUSIONS AND RELEVANCE: There are statistically significant and clinically relevant differences in time to a stable pressure reading when contaminates are introduced into a closed drainage system. Changing a transducer based on the presence of blood contaminate should be considered to improve accuracy but must be weighed against the risk of introducing infection.


Assuntos
Pressão Intracraniana , Transdutores de Pressão , Pressão Intracraniana/fisiologia , Humanos , Sangue/metabolismo , Glicerol , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Drenagem/instrumentação , Hemorragia Cerebral/fisiopatologia , Hemorragia Cerebral/diagnóstico
2.
Curr Opin Crit Care ; 30(3): 275-282, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38690957

RESUMO

PURPOSE OF REVIEW: Wearable wireless sensors for continuous vital signs monitoring (CVSM) offer the potential for early identification of patient deterioration, especially in low-intensity care settings like general wards. This study aims to review advances in wearable CVSM - with a focus on the general ward - highlighting the technological characteristics of CVSM systems, user perspectives and impact on patient outcomes by exploring recent evidence. RECENT FINDINGS: The accuracy of wearable sensors measuring vital signs exhibits variability, especially notable in ambulatory patients within hospital settings, and standard validation protocols are lacking. Usability of CMVS systems is critical for nurses and patients, highlighting the need for easy-to-use wearable sensors, and expansion of the number of measured vital signs. Current software systems lack integration with hospital IT infrastructures and workflow automation. Imperative enhancements involve nurse-friendly, less intrusive alarm strategies, and advanced decision support systems. Despite observed reductions in ICU admissions and Rapid Response Team calls, the impact on patient outcomes lacks robust statistical significance. SUMMARY: Widespread implementation of CVSM systems on the general ward and potentially outside the hospital seems inevitable. Despite the theoretical benefits of CVSM systems in improving clinical outcomes, and supporting nursing care by optimizing clinical workflow efficiency, the demonstrated effects in clinical practice are mixed. This review highlights the existing challenges related to data quality, usability, implementation, integration, interpretation, and user perspectives, as well as the need for robust evidence to support their impact on patient outcomes, workflow and cost-effectiveness.


Assuntos
Sinais Vitais , Dispositivos Eletrônicos Vestíveis , Humanos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Tecnologia sem Fio/instrumentação
3.
ACS Appl Mater Interfaces ; 16(19): 25181-25193, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38698676

RESUMO

Supermolecular hydrogel ionic skin (i-skin) linked with smartphones has attracted widespread attention in physiological activity detection due to its good stability in complex scenarios. However, the low ionic conductivity, inferior mechanical properties, poor contact adhesion, and insufficient freeze resistance of most used hydrogels limit their practical application in flexible electronics. Herein, a novel multifunctional poly(vinyl alcohol)-based conductive organohydrogel (PCEL5.0%) with a supermolecular structure was constructed by innovatively employing sodium carboxymethyl cellulose (CMC-Na) as reinforcement material, ethylene glycol as antifreeze, and lithium chloride as a water retaining agent. Thanks to the synergistic effect of these components, the PCEL5.0% organohydrogel shows excellent performance in terms of ionic conductivity (1.61 S m-1), mechanical properties (tensile strength of 70.38 kPa and elongation at break of 537.84%), interfacial adhesion (1.06 kPa to pig skin), frost resistance (-50.4 °C), water retention (67.1% at 22% relative humidity), and remoldability. The resultant PCEL5.0%-based i-skin delivers satisfactory sensitivity (GF = 1.38) with fast response (348 ms) and high precision under different deformations and low temperature (-25 °C). Significantly, the wireless sensor system based on the PCEL5.0% organohydrogel i-skin can transmit signals from physiological activities and sign language to a smartphone by Bluetooth technology and dynamically displays the status of these movements. The organohydrogel i-skin shows great potential in diverse fields of physiological activity detection, human-computer interaction, and rehabilitation medicine.


Assuntos
Hidrogéis , Hidrogéis/química , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Animais , Tecnologia sem Fio , Dispositivos Eletrônicos Vestíveis , Condutividade Elétrica , Humanos , Álcool de Polivinil/química , Suínos , Smartphone , Pele/química , Carboximetilcelulose Sódica/química
4.
Sensors (Basel) ; 24(9)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38732771

RESUMO

Human activity recognition (HAR) technology enables continuous behavior monitoring, which is particularly valuable in healthcare. This study investigates the viability of using an ear-worn motion sensor for classifying daily activities, including lying, sitting/standing, walking, ascending stairs, descending stairs, and running. Fifty healthy participants (between 20 and 47 years old) engaged in these activities while under monitoring. Various machine learning algorithms, ranging from interpretable shallow models to state-of-the-art deep learning approaches designed for HAR (i.e., DeepConvLSTM and ConvTransformer), were employed for classification. The results demonstrate the ear sensor's efficacy, with deep learning models achieving a 98% accuracy rate of classification. The obtained classification models are agnostic regarding which ear the sensor is worn and robust against moderate variations in sensor orientation (e.g., due to differences in auricle anatomy), meaning no initial calibration of the sensor orientation is required. The study underscores the ear's efficacy as a suitable site for monitoring human daily activity and suggests its potential for combining HAR with in-ear vital sign monitoring. This approach offers a practical method for comprehensive health monitoring by integrating sensors in a single anatomical location. This integration facilitates individualized health assessments, with potential applications in tele-monitoring, personalized health insights, and optimizing athletic training regimes.


Assuntos
Dispositivos Eletrônicos Vestíveis , Humanos , Adulto , Masculino , Feminino , Pessoa de Meia-Idade , Adulto Jovem , Atividades Humanas , Orelha/fisiologia , Algoritmos , Atividades Cotidianas , Aprendizado de Máquina , Aprendizado Profundo , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Movimento (Física) , Caminhada/fisiologia
5.
Sensors (Basel) ; 24(9)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38732777

RESUMO

Optical fiber sensors are extensively employed for their unique merits, such as small size, being lightweight, and having strong robustness to electronic interference. The above-mentioned sensors apply to more applications, especially the detection and monitoring of vital signs in medical or clinical. However, it is inconvenient for daily long-term human vital sign monitoring with conventional monitoring methods under the uncomfortable feelings generated since the skin and devices come into direct contact. This study introduces a non-invasive surveillance system that employs an optical fiber sensor and advanced deep-learning methodologies for precise vital sign readings. This system integrates a monitor based on the MZI (Mach-Zehnder interferometer) with LSTM networks, surpassing conventional approaches and providing potential uses in medical diagnostics. This could be potentially utilized in non-invasive health surveillance, evaluation, and intelligent health care.


Assuntos
Aprendizado Profundo , Fibras Ópticas , Sinais Vitais , Humanos , Sinais Vitais/fisiologia , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Redes Neurais de Computação
6.
Sensors (Basel) ; 24(9)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38732888

RESUMO

In today's health-monitoring applications, there is a growing demand for wireless and wearable acquisition platforms capable of simultaneously gathering multiple bio-signals from multiple body areas. These systems require well-structured software architectures, both to keep different wireless sensing nodes synchronized each other and to flush collected data towards an external gateway. This paper presents a quantitative analysis aimed at validating both the wireless synchronization task (implemented with a custom protocol) and the data transmission task (implemented with the BLE protocol) in a prototype wearable monitoring platform. We evaluated seven frequencies for exchanging synchronization packets (10 Hz, 20 Hz, 30 Hz, 40 Hz, 50 Hz, 60 Hz, 70 Hz) as well as two different BLE configurations (with and without the implementation of a dynamic adaptation of the BLE Connection Interval parameter). Additionally, we tested BLE data transmission performance in five different use case scenarios. As a result, we achieved the optimal performance in the synchronization task (1.18 ticks as median synchronization delay with a Min-Max range of 1.60 ticks and an Interquartile range (IQR) of 0.42 ticks) when exploiting a synchronization frequency of 40 Hz and the dynamic adaptation of the Connection Interval. Moreover, BLE data transmission proved to be significantly more efficient with shorter distances between the communicating nodes, growing worse by 30.5% beyond 8 m. In summary, this study suggests the best-performing network configurations to enhance the synchronization task of the prototype platform under analysis, as well as quantitative details on the best placement of data collectors.


Assuntos
Dispositivos Eletrônicos Vestíveis , Tecnologia sem Fio , Tecnologia sem Fio/instrumentação , Humanos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Redes de Comunicação de Computadores/instrumentação , Software
7.
Sensors (Basel) ; 24(9)2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38732899

RESUMO

This comprehensive review investigates the transformative potential of sensor-driven digital twin technology in enhancing healthcare delivery within smart environments. We explore the integration of smart environments with sensor technologies, digital health capabilities, and location-based services, focusing on their impacts on healthcare objectives and outcomes. This work analyzes the foundational technologies, encompassing the Internet of Things (IoT), Internet of Medical Things (IoMT), machine learning (ML), and artificial intelligence (AI), that underpin the functionalities within smart environments. We also examine the unique characteristics of smart homes and smart hospitals, highlighting their potential to revolutionize healthcare delivery through remote patient monitoring, telemedicine, and real-time data sharing. The review presents a novel solution framework leveraging sensor-driven digital twins to address both healthcare needs and user requirements. This framework incorporates wearable health devices, AI-driven health analytics, and a proof-of-concept digital twin application. Furthermore, we explore the role of location-based services (LBS) in smart environments, emphasizing their potential to enhance personalized healthcare interventions and emergency response capabilities. By analyzing the technical advancements in sensor technologies and digital twin applications, this review contributes valuable insights to the evolving landscape of smart environments for healthcare. We identify the opportunities and challenges associated with this emerging field and highlight the need for further research to fully realize its potential to improve healthcare delivery and patient well-being.


Assuntos
Inteligência Artificial , Atenção à Saúde , Internet das Coisas , Telemedicina , Dispositivos Eletrônicos Vestíveis , Humanos , Telemedicina/métodos , Aprendizado de Máquina , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação
8.
Sensors (Basel) ; 24(9)2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38732910

RESUMO

IoT has seen remarkable growth, particularly in healthcare, leading to the rise of IoMT. IoMT integrates medical devices for real-time data analysis and transmission but faces challenges in data security and interoperability. This research identifies a significant gap in the existing literature regarding a comprehensive ontology for vulnerabilities in medical IoT devices. This paper proposes a fundamental domain ontology named MIoT (Medical Internet of Things) ontology, focusing on cybersecurity in IoMT (Internet of Medical Things), particularly in remote patient monitoring settings. This research will refer to similar-looking acronyms, IoMT and MIoT ontology. It is important to distinguish between the two. IoMT is a collection of various medical devices and their applications within the research domain. On the other hand, MIoT ontology refers to the proposed ontology that defines various concepts, roles, and individuals. MIoT ontology utilizes the knowledge engineering methodology outlined in Ontology Development 101, along with the structured life cycle, and establishes semantic interoperability among medical devices to secure IoMT assets from vulnerabilities and cyberattacks. By defining key concepts and relationships, it becomes easier to understand and analyze the complex network of information within the IoMT. The MIoT ontology captures essential key terms and security-related entities for future extensions. A conceptual model is derived from the MIoT ontology and validated through a case study. Furthermore, this paper outlines a roadmap for future research, highlighting potential impacts on security automation in healthcare applications.


Assuntos
Segurança Computacional , Internet das Coisas , Humanos , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Telemedicina/métodos
9.
Sensors (Basel) ; 24(9)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38732992

RESUMO

In this contribution, a wearable microwave imaging system for real-time monitoring of brain stroke in the post-acute stage is described and validated. The system exploits multistatic/multifrequency (only 50 frequency samples) data collected via a low-cost and low-complexity architecture. Data are collected by an array of only 16 antennas moved by pneumatic system. Phantoms, built from ABS material and filled with appropriate Triton X-100-based mixtures to mimic the different head human tissues, are employed for the experiments. The microwave system exploits the differential scattering measures and the Incoherent MUSIC algorithm to provide a 3D image of the region under investigation. The shown results, although preliminary, confirm the potential of the proposed microwave system in providing reliable results, including for targets whose evolution is as small as 16 mL in volume.


Assuntos
Imagens de Fantasmas , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Algoritmos , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Micro-Ondas , Dispositivos Eletrônicos Vestíveis , Imageamento Tridimensional/métodos
10.
Sensors (Basel) ; 24(9)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38733009

RESUMO

Recent advancements in polymer-assisted layer-by-layer (LbL) fabrication have revolutionized the development of wearable sensors for health monitoring. LbL self-assembly has emerged as a powerful and versatile technique for creating conformal, flexible, and multi-functional films on various substrates, making it particularly suitable for fabricating wearable sensors. The incorporation of polymers, both natural and synthetic, has played a crucial role in enhancing the performance, stability, and biocompatibility of these sensors. This review provides a comprehensive overview of the principles of LbL self-assembly, the role of polymers in sensor fabrication, and the various types of LbL-fabricated wearable sensors for physical, chemical, and biological sensing. The applications of these sensors in continuous health monitoring, disease diagnosis, and management are discussed in detail, highlighting their potential to revolutionize personalized healthcare. Despite significant progress, challenges related to long-term stability, biocompatibility, data acquisition, and large-scale manufacturing are still to be addressed, providing insights into future research directions. With continued advancements in polymer-assisted LbL fabrication and related fields, wearable sensors are poised to improve the quality of life for individuals worldwide.


Assuntos
Técnicas Biossensoriais , Polímeros , Dispositivos Eletrônicos Vestíveis , Polímeros/química , Humanos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos
11.
Sensors (Basel) ; 24(9)2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38733040

RESUMO

Shoulder pain represents the most frequently reported musculoskeletal disorder, often leading to significant functional impairment and pain, impacting quality of life. Home-based rehabilitation programs offer a more accessible and convenient solution for an effective shoulder disorder treatment, addressing logistical and financial constraints associated with traditional physiotherapy. The aim of this systematic review is to report the monitoring devices currently proposed and tested for shoulder rehabilitation in home settings. The research question was formulated using the PICO approach, and the PRISMA guidelines were applied to ensure a transparent methodology for the systematic review process. A comprehensive search of PubMed and Scopus was conducted, and the results were included from 2014 up to 2023. Three different tools (i.e., the Rob 2 version of the Cochrane risk-of-bias tool, the Joanna Briggs Institute (JBI) Critical Appraisal tool, and the ROBINS-I tool) were used to assess the risk of bias. Fifteen studies were included as they fulfilled the inclusion criteria. The results showed that wearable systems represent a promising solution as remote monitoring technologies, offering quantitative and clinically meaningful insights into the progress of individuals within a rehabilitation pathway. Recent trends indicate a growing use of low-cost, non-intrusive visual tracking devices, such as camera-based monitoring systems, within the domain of tele-rehabilitation. The integration of home-based monitoring devices alongside traditional rehabilitation methods is acquiring significant attention, offering broader access to high-quality care, and potentially reducing healthcare costs associated with in-person therapy.


Assuntos
Dor de Ombro , Humanos , Dor de Ombro/reabilitação , Telerreabilitação/métodos , Dispositivos Eletrônicos Vestíveis , Qualidade de Vida , Ombro , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Serviços de Assistência Domiciliar , Modalidades de Fisioterapia/instrumentação
12.
Sensors (Basel) ; 24(9)2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38733046

RESUMO

Incorrect sitting posture, characterized by asymmetrical or uneven positioning of the body, often leads to spinal misalignment and muscle tone imbalance. The prolonged maintenance of such postures can adversely impact well-being and contribute to the development of spinal deformities and musculoskeletal disorders. In response, smart sensing chairs equipped with cutting-edge sensor technologies have been introduced as a viable solution for the real-time detection, classification, and monitoring of sitting postures, aiming to mitigate the risk of musculoskeletal disorders and promote overall health. This comprehensive literature review evaluates the current body of research on smart sensing chairs, with a specific focus on the strategies used for posture detection and classification and the effectiveness of different sensor technologies. A meticulous search across MDPI, IEEE, Google Scholar, Scopus, and PubMed databases yielded 39 pertinent studies that utilized non-invasive methods for posture monitoring. The analysis revealed that Force Sensing Resistors (FSRs) are the predominant sensors utilized for posture detection, whereas Convolutional Neural Networks (CNNs) and Artificial Neural Networks (ANNs) are the leading machine learning models for posture classification. However, it was observed that CNNs and ANNs do not outperform traditional statistical models in terms of classification accuracy due to the constrained size and lack of diversity within training datasets. These datasets often fail to comprehensively represent the array of human body shapes and musculoskeletal configurations. Moreover, this review identifies a significant gap in the evaluation of user feedback mechanisms, essential for alerting users to their sitting posture and facilitating corrective adjustments.


Assuntos
Postura Sentada , Humanos , Redes Neurais de Computação , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Postura/fisiologia
13.
JMIR Mhealth Uhealth ; 12: e50620, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38717366

RESUMO

Background: Wearables that measure vital parameters can be potential tools for monitoring patients at home during cancer treatment. One type of wearable is a smart T-shirt with embedded sensors. Initially, smart T-shirts were designed to aid athletes in their performance analyses. Recently however, researchers have been investigating the use of smart T-shirts as supportive tools in health care. In general, the knowledge on the use of wearables for symptom monitoring during cancer treatment is limited, and consensus and awareness about compliance or adherence are lacking. objectives: The aim of this study was to evaluate adherence to and experiences with using a smart T-shirt for the home monitoring of biometric sensor data among adolescent and young adult patients undergoing cancer treatment during a 2-week period. Methods: This study was a prospective, single-cohort, mixed methods feasibility study. The inclusion criteria were patients aged 18 to 39 years and those who were receiving treatment at Copenhagen University Hospital - Rigshospitalet, Denmark. Consenting patients were asked to wear the Chronolife smart T-shirt for a period of 2 weeks. The smart T-shirt had multiple sensors and electrodes, which engendered the following six measurements: electrocardiogram (ECG) measurements, thoracic respiration, abdominal respiration, thoracic impedance, physical activity (steps), and skin temperature. The primary end point was adherence, which was defined as a wear time of >8 hours per day. The patient experience was investigated via individual, semistructured telephone interviews and a paper questionnaire. Results: A total of 10 patients were included. The number of days with wear times of >8 hours during the study period (14 d) varied from 0 to 6 (mean 2 d). Further, 3 patients had a mean wear time of >8 hours during each of their days with data registration. The number of days with any data registration ranged from 0 to 10 (mean 6.4 d). The thematic analysis of interviews pointed to the following three main themes: (1) the smart T-shirt is cool but does not fit patients with cancer, (2) the technology limits the use of the smart T-shirt, and (3) the monitoring of data increases the feeling of safety. Results from the questionnaire showed that the patients generally had confidence in the device. Conclusions: Although the primary end point was not reached, the patients' experiences with using the smart T-shirt resulted in the knowledge that patients acknowledged the need for new technologies that improve supportive cancer care. The patients were positive when asked to wear the smart T-shirt. However, technical and practical challenges in using the device resulted in low adherence. Although wearables might have potential for home monitoring, the present technology is immature for clinical use.


Assuntos
Estudos de Viabilidade , Neoplasias , Dispositivos Eletrônicos Vestíveis , Humanos , Adolescente , Masculino , Estudos Prospectivos , Feminino , Neoplasias/psicologia , Neoplasias/terapia , Adulto , Dispositivos Eletrônicos Vestíveis/estatística & dados numéricos , Dispositivos Eletrônicos Vestíveis/normas , Dispositivos Eletrônicos Vestíveis/psicologia , Estudos de Coortes , Dinamarca , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Adulto Jovem
14.
Artigo em Inglês | MEDLINE | ID: mdl-38723798

RESUMO

Wearable and implantable sensing of biomechanical signals such as pressure, strain, shear, and vibration can enable a multitude of human-integrated applications, including on-skin monitoring of vital signs, motion tracking, monitoring of internal organ condition, restoration of lost/impaired mechanoreception, among many others. The mechanical conformability of such sensors to the human skin and tissue is critical to enhancing their biocompatibility and sensing accuracy. As such, in the recent decade, significant efforts have been made in the development of soft mechanical sensors. To satisfy the requirements of different wearable and implantable applications, such sensors have been imparted with various additional properties to make them better suited for the varied contexts of human-integrated applications. In this review, focusing on the four major types of soft mechanical sensors for pressure, strain, shear, and vibration, we discussed the recent material and device design innovations for achieving several important properties, including flexibility and stretchability, bioresorbability and biodegradability, self-healing properties, breathability, transparency, wireless communication capabilities, and high-density integration. We then went on to discuss the current research state of the use of such novel soft mechanical sensors in wearable and implantable applications, based on which future research needs were further discussed. This article is categorized under: Diagnostic Tools > Biosensing Diagnostic Tools > Diagnostic Nanodevices Implantable Materials and Surgical Technologies > Nanomaterials and Implants.


Assuntos
Próteses e Implantes , Dispositivos Eletrônicos Vestíveis , Humanos , Desenho de Equipamento , Técnicas Biossensoriais/instrumentação , Monitorização Fisiológica/instrumentação
15.
Sensors (Basel) ; 24(9)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38733027

RESUMO

Heart failure (HF) is a complex clinical syndrome associated with significant morbidity, mortality, and healthcare costs. It is characterized by various structural and/or functional abnormalities of the heart, resulting in elevated intracardiac pressure and/or inadequate cardiac output at rest and/or during exercise. These dysfunctions can originate from a variety of conditions, including coronary artery disease, hypertension, cardiomyopathies, heart valve disorders, arrhythmias, and other lifestyle or systemic factors. Identifying the underlying cause is crucial for detecting reversible or treatable forms of HF. Recent epidemiological studies indicate that there has not been an increase in the incidence of the disease. Instead, patients seem to experience a chronic trajectory marked by frequent hospitalizations and stagnant mortality rates. Managing these patients requires a multidisciplinary approach that focuses on preventing disease progression, controlling symptoms, and preventing acute decompensations. In the outpatient setting, patient self-care plays a vital role in achieving these goals. This involves implementing necessary lifestyle changes and promptly recognizing symptoms/signs such as dyspnea, lower limb edema, or unexpected weight gain over a few days, to alert the healthcare team for evaluation of medication adjustments. Traditional methods of HF monitoring, such as symptom assessment and periodic clinic visits, may not capture subtle changes in hemodynamics. Sensor-based technologies offer a promising solution for remote monitoring of HF patients, enabling early detection of fluid overload and optimization of medical therapy. In this review, we provide an overview of the CardioMEMS device, a novel sensor-based system for pulmonary artery pressure monitoring in HF patients. We discuss the technical aspects, clinical evidence, and future directions of CardioMEMS in HF management.


Assuntos
Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Cardiologia/métodos , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Gerenciamento Clínico , Hemodinâmica/fisiologia
16.
Crit Care Sci ; 36: e20240196en, 2024.
Artigo em Inglês, Português | MEDLINE | ID: mdl-38775544

RESUMO

OBJECTIVE: To provide insights into the potential benefits of goal-directed therapy guided by FloTrac in reducing postoperative complications and improving outcomes. METHODS: We performed a systematic review and meta-analysis of randomized controlled trials to evaluate goal-directed therapy guided by FloTrac in major surgery, comparing goal-directed therapy with usual care or invasive monitoring in cardiac and noncardiac surgery subgroups. The quality of the articles and evidence were evaluated with a risk of bias tool and GRADE. RESULTS: We included 29 randomized controlled trials with 3,468 patients. Goal-directed therapy significantly reduced the duration of hospital stay (mean difference -1.43 days; 95%CI 2.07 to -0.79; I2 81%), intensive care unit stay (mean difference -0.77 days; 95%CI -1.18 to -0.36; I2 93%), and mechanical ventilation (mean difference -2.48 hours, 95%CI -4.10 to -0.86, I2 63%). There was no statistically significant difference in mortality, myocardial infarction, acute kidney injury or hypotension, but goal-directed therapy significantly reduced the risk of heart failure or pulmonary edema (RR 0.46; 95%CI 0.23 - 0.92; I2 0%). CONCLUSION: Goal-directed therapy guided by the FloTrac sensor improved clinical outcomes and shortened the length of stay in the hospital and intensive care unit in patients undergoing major surgery. Further research can validate these results using specific protocols and better understand the potential benefits of FloTrac beyond these outcomes.


Assuntos
Tempo de Internação , Complicações Pós-Operatórias , Humanos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Ensaios Clínicos Controlados Aleatórios como Assunto , Unidades de Terapia Intensiva , Respiração Artificial , Terapia Precoce Guiada por Metas/métodos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos
17.
J Mater Chem B ; 12(19): 4655-4665, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38646701

RESUMO

Developing soft wearable sensors with high sensitivity, low cost, and a wide monitoring range is crucial for monitoring human health. Despite advances in strain sensor technology, achieving high sensitivity and a wide operating range in a single device remains a major challenge in its design and preparation. Herein, a liquid metal (LM) is innovatively ultrasonically anchored to the gaps and surfaces of thermoplastic polyurethane (TPU) electrospun fibers, and then a conductive pathway is constructed through polypyrrole (PPy) self-polymerization to prepare a composite film. The strain sensor developed by ultrasonic anchoring and original polymerization technology shows a high strain coefficient (GF = 4.36 at 12.5% strain) and a low detection limit (less than 1% strain). Importantly, this sensor can monitor joint motion and subtle skin deformations in real time. In addition, the integration of strain sensors and N95 masks enables real-time monitoring of human respiration.


Assuntos
Polímeros , Poliuretanos , Pirróis , Dispositivos Eletrônicos Vestíveis , Pirróis/química , Humanos , Polímeros/química , Poliuretanos/química , Condutividade Elétrica , Propriedades de Superfície , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Tamanho da Partícula
18.
J Med Internet Res ; 26: e52075, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38683665

RESUMO

BACKGROUND: Current heart failure (HF) guidelines recommend a multidisciplinary approach, discharge education, and self-management for HF. However, the recommendations are challenging to implement in real-world clinical settings. OBJECTIVE: We developed a mobile health (mHealth) platform for HF self-care to evaluate whether a smartphone app-based intervention with Bluetooth-connected monitoring devices and a feedback system can help improve HF symptoms. METHODS: In this prospective, randomized, multicenter study, we enrolled patients 20 years of age and older, hospitalized for acute HF, and who could use a smartphone from 7 tertiary hospitals in South Korea. In the intervention group (n=39), the apps were automatically paired with Bluetooth-connected monitoring devices. The patients could enter information on vital signs, HF symptoms, diet, medications, and exercise regimen into the app daily and receive feedback or alerts on their input. In the control group (n=38), patients could only enter their blood pressure, heart rate, and weight using conventional, non-Bluetooth devices and could not receive any feedback or alerts from the app. The primary end point was the change in dyspnea symptom scores from baseline to 4 weeks, assessed using a questionnaire. RESULTS: At 4 weeks, the change in dyspnea symptom score from baseline was significantly greater in the intervention group than in the control group (mean -1.3, SD 2.1 vs mean -0.3, SD 2.3; P=.048). A significant reduction was found in body water composition from baseline to the final measurement in the intervention group (baseline level mean 7.4, SD 2.5 vs final level mean 6.6, SD 2.5; P=.003). App adherence, which was assessed based on log-in or the percentage of days when symptoms were first observed, was higher in the intervention group than in the control group. Composite end points, including death, rehospitalization, and urgent HF visits, were not significantly different between the 2 groups. CONCLUSIONS: The mobile-based health platform with Bluetooth-connected monitoring devices and a feedback system demonstrated improvement in dyspnea symptoms in patients with HF. This study provides evidence and rationale for implementing mobile app-based self-care strategies and feedback for patients with HF. TRIAL REGISTRATION: ClinicalTrials.gov NCT05668000; https://clinicaltrials.gov/study/NCT05668000.


Assuntos
Insuficiência Cardíaca , Aplicativos Móveis , Smartphone , Humanos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Estudos Prospectivos , República da Coreia , Retroalimentação , Telemedicina/métodos , Autocuidado/métodos , Autocuidado/instrumentação , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação
19.
Sensors (Basel) ; 24(8)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38676163

RESUMO

Heart failure (HF) is a multi-faceted, complex clinical syndrome characterized by significant morbidity, high mortality rate, reduced quality of life, and rapidly increasing healthcare costs. A larger proportion of these costs comprise both ambulatory and emergency department visits, as well as hospital admissions. Despite the methods used by telehealth (TH) to improve self-care and quality of life, patient outcomes remain poor. HF management is associated with numerous challenges, such as conflicting evidence from clinical trials, heterogeneity of TH devices, variability in patient inclusion and exclusion criteria, and discrepancies between healthcare systems. A growing body of evidence suggests there is an unmet need for increased individualization of in-hospital management, continuous remote monitoring of patients pre and post-hospital admission, and continuation of treatment post-discharge in order to reduce re-hospitalizations and improve long-term outcomes. This review summarizes the current state-of-the-art for HF and associated novel technologies and advancements in the most frequently used types of TH (implantable sensors), categorizing devices in their preclinical and clinical stage, bench-to-bedside implementation challenges, and future perspectives on remote HF management to improve long-term outcomes of HF patients. The Review also highlights recent advancements in non-invasive remote monitoring technologies demonstrated by a few pilot observational prospective cohort studies.


Assuntos
Insuficiência Cardíaca , Telemedicina , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico , Humanos , Telemedicina/métodos , Qualidade de Vida , Doença Crônica , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação
20.
J Colloid Interface Sci ; 668: 142-153, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38669992

RESUMO

Based on real-time detection of plantar pressure, gait recognition could provide important health information for rehabilitation administration, fatigue prevention, and sports training assessment. So far, such researches are extremely limited due to lacking of reliable, stable and comfortable plantar pressure sensors. Herein, a strategy for preparing high compression strength and resilience conductive iongels has been proposed by implanting physically entangled polymer chains with covalently cross-linked networks. The resulting iongels have excellent mechanical properties including nice compliance (young's modulus < 300 kPa), high compression strength (>10 MPa at a strain of 90 %), and good resilience (self-recovery within seconds). And capacitive pressure sensor composed by them possesses excellent sensitivity, good linear response even under very small stress (∼kPa), and long-term durability (cycles > 100,000) under high-stress conditions (133 kPa). Then, capacitive pressure sensor arrays have been prepared for high-precision detection of plantar pressure spatial distribution, which also exhibit excellent sensing performances and long-term stability. Further, an extremely sensitive and fast response plantar pressure monitoring system has been designed for monitoring plantar pressure of foot at different postures including upright, forward and backward. The system achieves real-time tracking and monitoring of changes of plantar pressure during different static and dynamic posture processes. And the characteristics of plantar pressure information can be digitally and photography displayed. Finally, we propose an intelligent framework for real-time detection of plantar pressure by combining electronic insoles with data analysis system, which presents excellent applications in sport trainings and safety precautions.


Assuntos
Pressão , Humanos , Condutividade Elétrica , Pé/fisiologia , Monitorização Fisiológica/instrumentação , Marcha/fisiologia , Propriedades de Superfície , Dispositivos Eletrônicos Vestíveis
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA