1.
Anesth Analg ; 133(5): 1132-1137, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34427566

RESUMO

Capnometry, the measurement of respiratory carbon dioxide, is regarded as a highly recommended safety technology in intubated and nonintubated sedated and/or anesthetized patients. Its utility includes confirmation of initial and ongoing placement of an airway device as well as in detecting gas exchange, bronchospasm, airway obstruction, reduced cardiac output, and metabolic changes. The utility applies prehospital and throughout all phases of inhospital care. Unfortunately, capnometry devices are not readily available in many countries, especially those that are resource-limited. Constraining factors include cost, durability of devices, availability of consumables, lack of dependable power supply, difficulty with cleaning, and maintenance. There is, thus, an urgent need for all stakeholders to come together to develop, market, and distribute appropriate devices that address costs and other requirements. To foster this process, the World Federation of Societies of Anaesthesiologists (WFSA) has developed the "WFSA-Minimum Capnometer Specifications 2021." The intent of the specifications is to set the minimum that would be acceptable from industry in their attempts to reduce costs while meeting other needs in resource-constrained regions. The document also includes very desirable and preferred options. The intent is to stimulate interest and engagement among industry, clinical providers, professional associations, and ministries of health to address this important patient safety need. The WFSA-Minimum Capnometer Specifications 2021 is based on the International Organization for Standardization (ISO) capnometer specifications. While industry is familiar with such specifications and their presentation format, most clinicians are not; therefore, this article serves to more clearly explain the requirements. In addition, the specifications as described can be used as a purchasing guide by clinicians.


Assuntos
Anestesiologia/instrumentação , Monitorização Transcutânea dos Gases Sanguíneos/instrumentação , Dióxido de Carbono/metabolismo , Monitorização Intraoperatória/instrumentação , Anestesiologia/economia , Anestesiologia/normas , Monitorização Transcutânea dos Gases Sanguíneos/economia , Monitorização Transcutânea dos Gases Sanguíneos/normas , Desenho de Equipamento , Custos de Cuidados de Saúde , Acessibilidade aos Serviços de Saúde/economia , Humanos , Monitorização Intraoperatória/economia , Monitorização Intraoperatória/normas , Sociedades Médicas
2.
Dev Neurorehabil ; 24(5): 303-310, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33423573

RESUMO

Objective: To assess the quality of SpO2 and PCO2 recordings via transcutaneous monitoring in children with neurological conditions.Methods: Overnight transcutaneous SpO2 and PCO2 were analyzed. The presence of drift and drift correction was noted, and the rate of disrupted recordings scored (0: absence, 1; presence). The quality of recordings was also scored (0, 1, 2 for poor, medium, and high).Results: A total of 228 recordings from 64 children aged 9.7 ± 6 years were analyzed of which 42 used positive pressure respiratory support. The mean quality of the recordings was scored as 1.27 (0-2). PCO2 drift, drift correction, and disrupted recordings were present in 25%, 58%, and 26% of recordings, respectively. Satisfactory clinical decisions were taken in 91% of cases.Conclusion: The quality of transcutaneous sensor recordings was acceptable and clinical findings were deemed as satisfactory in the large majority of cases. Correction of PCO2 drift was challenging.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/normas , Dióxido de Carbono/sangue , Oxigênio/sangue , Síndromes da Apneia do Sono/sangue , Adolescente , Doenças do Sistema Nervoso Central/sangue , Doenças do Sistema Nervoso Central/fisiopatologia , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Doenças Neuromusculares/sangue , Doenças Neuromusculares/fisiopatologia , Pressão Parcial , Respiração com Pressão Positiva , Garantia da Qualidade dos Cuidados de Saúde , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/fisiopatologia , Síndromes da Apneia do Sono/terapia
3.
J Neuromuscul Dis ; 8(2): 305-313, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32925087

RESUMO

BACKGROUND: Carbon dioxide tension (PCO2) monitoring during sleep, is crucial to identify respiratory failure in patients with neuromuscular disorders (NMD). Transcutaneous PCO2 monitoring is an available technique to measure PCO2. OBJECTIVES: To assess the quality level of transcutaneous blood gas measurements via SenTec monitor. METHODS: A 12-month analysis of SenTec measurements was conducted in a Belgian Centre for Home Mechanical Ventilation (HMV). Over two consecutive nights; SpO2 and PCO2 measurements, the presence of PCO2 drift and drift correction with SenTec, were reviewed and scores (0, 1, 2 for poor, medium and high level) were assigned to estimate the quality of measurements. RESULTS: Sixty-nine NMD patients met the inclusion criteria, of which 48/69 used HMV. PCO2 drift and drift correction were present in 15% and 68% of the 138 recordings, respectively. The quality level of measurements throughout night 1, scored 1.55 (0-2). The relevance of our clinical findings from SenTec scoring 1.94 (1-2); was considered highly satisfactory. HMV was ineffective in 24/48 patients. Among 12 patients with hypercapnia, 8 patients improved PCO2 between night 1 and 2. Among 12 patients with hypocapnia, PCO2 improved in 4/12 patients, who reached the range of normal PCO2 (35-47 mmHg). CONCLUSIONS: The quality of SenTec measurements was acceptable in the majority of recordings and clinical findings were deemed satisfactory in all cases. A single SenTec measurement was sufficient to determine the need for NIV. However, two SenTec registrations were insufficient to both improve NIV effectiveness in 50% of cases, and, to ensure follow-up of our interventions.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/normas , Dióxido de Carbono/sangue , Doenças Neuromusculares/sangue , Adulto , Gasometria/métodos , Feminino , Humanos , Hipercapnia/sangue , Masculino , Pessoa de Meia-Idade , Respiração Artificial , Insuficiência Respiratória/diagnóstico , Estudos Retrospectivos
4.
Eur J Anaesthesiol ; 36(12): 904-910, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31464713

RESUMO

BACKGROUND: Transcutaneous carbon dioxide measurement (TcCO2) is frequently used as a surrogate for arterial blood gas sampling in adults and children with critical illness. Data from noninvasive TcCO2 monitoring assists with clinical decisions regarding mechanical ventilation settings, estimation of metabolic consumption and determination of adequate end-organ tissue perfusion. OBJECTIVES: To report TcCO2 values obtained from various fruits, vegetables and elite critical care medicine specialists. DESIGN: Prospective, observational, nonblinded cohort study. SETTINGS: Single-centre, tertiary paediatric referral centre and organic farmers' market. PARTICIPANTS: Vegetables and fruits included 10 samples of each of the following: red delicious apple (Malus domestica), manzano banana (Musa sapientum), key lime (Citrus aurantiifolia), miniature sweet bell pepper (Capsicum annuum), sweet potato (Ipomoea batatas) and avocado (Persea americana). Ten human controls were studied including a paediatric intensivist, a paediatric inpatient hospital physician, four paediatric resident physicians and four paediatric critical care nurses. INTERVENTIONS: None. MAIN OUTCOME MEASURES: TcCO2 values for each species and device response times. RESULTS: TcCO2 readings were measurable in all study species except the sweet potato. Mean ±â€ŠSD values of TcCO2 for human controls [4.34 ±â€Š0.37 kPa (32.6 ±â€Š2.8 mmHg)] were greater than apples [3.09 ±â€Š0.19 kPa (23.2 ±â€Š1.4 mmHg), P < 0.01], bananas [2.73 ±â€Š0.28 kPa (20.5 ±â€Š2.1 mmHg), P < 0.01] and limes [2.76 ±â€Š0.52 kPa (20.7 ±â€Š3.9 mmHg), P < 0.01] but no different to those of avocados [4.29 ±â€Š0.44 kPa (32.2 ±â€Š3.3 mmHg), P = 0.77] and bell peppers [4.19 ±â€Š1.13 kPa (31.4 ±â€Š8.5 mmHg), P = 0.68]. Transcutaneous response times did not differ between research cohorts and human controls. CONCLUSION: We found nonroot, nontuberous vegetables to have TcCO2 values similar to that of healthy, human controls. Fruits yield TcCO2 readings, but substantially lower than human controls.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/métodos , Dióxido de Carbono/análise , Frutas/química , Verduras/química , Adulto , Monitorização Transcutânea dos Gases Sanguíneos/normas , Feminino , Humanos , Masculino , Estudos Prospectivos , Valores de Referência
5.
Intensive Crit Care Nurs ; 38: 46-52, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27843027

RESUMO

OBJECTIVES: This present study was designed to determine the efficacy of the colorimetric capnometry method used to verify the correct placement of the nasogastric tube. METHODS: The present study comprised forty patients who had a nasogastric tube inserted and were being monitored in the adult intensive care unit. After the insertion of the nasogastric tube, 40 colorimetric capnometry and 40 auscultation measurements were performed. Auscultation and colorimetric capnometry results were compared with tube placement results confirmed radiologically. RESULTS: In the confirmation of the placement of the nasogastric tube, the consistency was 97.5% (p<0.05) between the colorimetric capnometry method and the radiological method, and 82.5% (p>0.05) between the auscultatory method and the radiological method. The oesophageal placement of the nasogastric tube was detected with the colorimetric capnometry method, but the gastric and duodenal insertions were not determined. While the sensitivity and specificity of the colorimetric capnometry method in determining the correct placement of the nasogastric tube were 1.00 and 0.667 respectively, those of the auscultatory method were 0.89 and 0.0 respectively. CONCLUSION: As a result, for the confirmation of the NGT placement, the colorimetric capnometry method is considered more reliable than the auscultatory method and is compatible with the radiological method. However, the colorimetric capnometry method is inadequate to distinguish between the gastric or duodenal insertion.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/normas , Intubação Gastrointestinal/normas , Sensibilidade e Especificidade , Resultado do Tratamento , Adulto , Auscultação/enfermagem , Auscultação/normas , Dióxido de Carbono/análise , Cor , Feminino , Humanos , Unidades de Terapia Intensiva/organização & administração , Intubação Gastrointestinal/enfermagem , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
6.
Adv Exp Med Biol ; 858: 39-46, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25820668

RESUMO

Transcutaneous measurement of oxygen and carbon dioxide pressure (PtcO2 and PtcCO2) is useful in gas exchange monitoring. However, the relationship between PtcO2, pulse oximetry (SaO2) and arterial blood gases (ABG) is unclear. The aim of the present study was to compare PtcO2 and PtcCO2 with SaO2 and ABG, to evaluate the effect of sensor location on the results and stability of PtcO2 and PtcCO2, and to assess the impact of body composition on PtcO2 and PtcCO2. PtcO2 and PtcCO2 were measured in 20 healthy volunteers at three locations: right second intercostal space, lateral surface of the abdomen, and the inner surface of the left arm. The results were recorded 10, 15, and 20 min after sensor fixation and compared with SaO2 and ABG measured 20 min after electrode placement on the chest. Body composition was evaluated by bioimpedance. The findings were that PtcO2 was stable on the chest; but on the arm and abdomen it increased and reached maximum at 20 min. Transcutaneous PCO2 stabilized at 10 min in all the three locations. No significant correlations between PtcO2 and SaO2 or PaO2 were found. Transcutaneous PCO2 correlated with PaCO2. Both PtcO2 and PtcCO2 were not influenced by body composition. We conclude that the value of PtcO2 in monitoring of blood oxygenation was not unequivocally confirmed; PtcCO2 reliably reflects PaCO2, irrespective of sensor location. Body composition does not affect PtcO2 and PtcCO2.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/normas , Dióxido de Carbono/sangue , Monitorização Fisiológica/normas , Oxigênio/sangue , Abdome , Adulto , Braço , Monitorização Transcutânea dos Gases Sanguíneos/instrumentação , Composição Corporal/fisiologia , Impedância Elétrica , Eletrodos , Feminino , Humanos , Masculino , Monitorização Fisiológica/instrumentação , Tórax
7.
Diving Hyperb Med ; 44(3): 146-53, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25311321

RESUMO

INTRODUCTION: Current guidelines for transcutaneous oximetry measurement (TCOM) for the lower limb define tissue hypoxia as a transcutaneous oxygen partial pressure < 40 mmHg. Values obtained with some newer machines and current research bring these reference values into question. AIM: To determine 'normal' TCOM values for the lower limb in healthy, non-smoking adults using the TCM400 oximeter with tc Sensor E5250. METHOD: Thirty-two healthy, non-smoking volunteers had TCOM performed at six positions on the lower leg and foot. Measurements were taken with subjects lying supine breathing air, then with leg elevated and whilst breathing 100 % oxygen. RESULTS: Room-air TCOM values (mean mmHg, 95 % confidence interval (CI) ) were: lateral leg 41.3, CI 37.8 to 44.7; lateral malleolus 38.6, CI 34.1 to 43.1; medial malleolus 43.9, CI 40.2 to 47.6; dorsum, between first and second toe 39.3, CI 35.9 to 42.7; dorsum, proximal to fifth metatarsal-phalangeal joint 46.4, CI 43.4 to 49.3; plantar 52.3, CI 49.6 to 55.1. Using the currently accepted value of less than 40 mmHg for tissue hypoxia, 24 of our 32 'healthy' subjects had at least one air sensor reading that would have been classified as hypoxic. Seventeen subjects had TCOM values less than 100 mmHg when breathing 100 % normobaric oxygen. CONCLUSION: Normal lower limb TCOM readings using the TCOM400 with tc Sensor E5250 may be lower than 40 mmHg, used to define tissue hypoxia, but consistent with the wide range of values found in the literature. Because of the wide variability in TCOM at the different sensor sites we cannot recommend one TCOM value as indicative of tissue hypoxia. A thorough clinical assessment of the patient is essential to establish appropriateness for hyperbaric oxygen treatment, with TCOM used as an aid to help guide this decision, but not as an absolute diagnostic tool.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/normas , Perna (Membro) , Adulto , Idoso , Idoso de 80 Anos ou mais , Monitorização Transcutânea dos Gases Sanguíneos/instrumentação , Hipóxia Celular , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Valores de Referência , Estatísticas não Paramétricas , Adulto Jovem
8.
J Wound Ostomy Continence Nurs ; 41(5): 430-5, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25188799

RESUMO

PURPOSE: Transcutaneous partial oxygen tension (TcpO2) is considered the gold standard for assessment of tissue oxygenation, which is an essential factor for wound healing. The purpose of this study was to evaluate the association between macrocirculation and TcpO2 in persons with diabetes mellitus. SUBJECTS AND SETTING: Ninety-eight patients with diabetic foot ulcers participated in the study (61 men and 37 women). The subjects had a mean age of 66.6 years (range, 30-83 years) and were treated at the Diabetic Wound Center of Korea University Guro Hospital, Seoul, Republic of Korea. METHODS: Macrocirculation was evaluated using 2 techniques: computed tomographic angiography and Doppler ultrasound. Macrocirculation scores were based on the patency of the two tibial arteries in 98 patients. Computed tomographic angiography and Doppler ultrasound scores (0-4 points) were given according to intraluminal filling defects and arterial pulse waveform of each vessel, respectively. Tissue oxygenation was measured by TcpO2. Macrocirculation scores were statistically analyzed as a function of the TcpO2. RESULTS: Statistical analysis revealed no significant linear trend between the macrocirculation status and TcpO2. Biavariate analysis using the Fisher exact test, Mantel-Haenszel tests, and McNemar-Bowker tests also found no significant relationship between macrocirculation and TcpO2. CONCLUSIONS: Computed tomographic angiography and Doppler ultrasound are not sufficiently reliable substitutes for TcpO2 measurements in regard to determining the optimal treatment for diabetic patients.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/métodos , Pé Diabético/mortalidade , Pé/irrigação sanguínea , Valor Preditivo dos Testes , Sobrevivência de Tecidos/fisiologia , Cicatrização/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Monitorização Transcutânea dos Gases Sanguíneos/normas , Pé Diabético/complicações , Pé Diabético/terapia , Feminino , Pé/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade
9.
Anesth Analg ; 117(1): 69-75, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23632055

RESUMO

BACKGROUND: Current methods for monitoring ventilatory rate have limitations including poor accuracy and precision and low patient tolerance. In this study, we evaluated a new acoustic ventilatory rate monitoring technology for accuracy, precision, reliability, and the ability to detect pauses in ventilation, relative to capnometry and a reference method in postsurgical patients. METHODS: Adult patients presenting to the postanesthesia care unit were connected to a Pulse CO-Oximeter with acoustic monitoring technology (Rad-87, version 7804, Masimo, Irvine, CA) through an adhesive bioacoustic sensor (RAS-125, rev C) applied to the neck. Each subject also wore a nasal cannula connected to a bedside capnometer (Capnostream20, version 4.5, Oridion, Needham, MA). The acoustic monitor and capnometer were connected to a computer for continuous acoustic and expiratory carbon dioxide waveform recordings. Recordings were retrospectively analyzed by a trained technician in a setting that allowed for the simultaneous viewing of both waveforms while listening to the breathing sounds from the acoustic signal to determine inspiration and expiration reference markers within the ventilatory cycle without using the acoustic monitor- or capnometer-calculated ventilatory rate. This allowed the automatic calculation of a reference ventilatory rate for each device through a software program (TagEditor, Masimo). Accuracy (relative to the respective reference) and precision of each device were estimated and compared with each other. Sensitivity for detection of pauses in ventilation, defined as no inspiration or expiration activity in the reference ventilatory cycle for ≥30 seconds, was also determined. The devices were also evaluated for their reliability, i.e., the percentage of the time when each displayed a value and did not drop a measurement. RESULTS: Thirty-three adults (73% female) with age of 45 ± 14 years and weight 117 ± 42 kg were enrolled. A total of 3712 minutes of monitoring time (average 112 minutes per subject) were analyzed across the 2 devices, reference ventilatory rates ranged from 1.9 to 49.1 bpm. Acoustic monitoring showed significantly greater accuracy (P = 0.0056) and precision (P- = 0.0024) for respiratory rate as compared with capnometry. On average, both devices displayed data over 97% of the monitored time. The (0.95, 0.95) lower tolerance limits for the acoustic monitor and capnometer were 94% and 84%, respectively. Acoustic monitoring was marginally more sensitive (P = 0.0461) to pauses in ventilation (81% vs 62%) in 21 apneic events. CONCLUSIONS: In this study of a population of postsurgical patients, the acoustic monitor and capnometer both reliably monitored ventilatory rate. The acoustic monitor was statistically more accurate and more precise than the capnometer, but differences in performance were modest. It is not known whether the observed differences are clinically significant. The acoustic monitor was more sensitive to detecting pauses in ventilation. Acoustic monitoring may provide an effective and convenient means of monitoring ventilatory rate in postsurgical patients.


Assuntos
Oximetria/normas , Cuidados Pós-Operatórios/normas , Taxa Respiratória/fisiologia , Som , Adulto , Monitorização Transcutânea dos Gases Sanguíneos/instrumentação , Monitorização Transcutânea dos Gases Sanguíneos/métodos , Monitorização Transcutânea dos Gases Sanguíneos/normas , Capnografia/instrumentação , Capnografia/métodos , Capnografia/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Monitorização Fisiológica/normas , Oximetria/instrumentação , Oximetria/métodos , Cuidados Pós-Operatórios/instrumentação , Cuidados Pós-Operatórios/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos
10.
Emerg Med J ; 30(6): 506-8, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22833591

RESUMO

BACKGROUND: This study evaluated the feasibility of prehospital tissue oxygen saturation (StO2) in major trauma patients. METHODS: A prospective, pilot feasibility study carried out in a physician based prehospital trauma service. RESULTS: Prehospital StO2 was recorded on 13 patients. Continuous StO2 monitoring was achieved on all patients, despite intermittent failure of pulse oximetry and non-invasive blood pressure monitoring in six patients. No adverse outcomes of StO2 monitoring were reported. The specific equipment used was reported to be inconveniently bulky and heavy for use in the prehospital setting. CONCLUSIONS: Prehospital measurement and monitoring of StO2 is feasible in trauma patients undergoing prehospital anaesthesia and may be useful in the early identification of shock, triggering of transfusion protocols and guiding fluid resuscitation.


Assuntos
Serviços Médicos de Emergência/métodos , Oximetria , Oxigênio/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Monitorização Transcutânea dos Gases Sanguíneos/instrumentação , Monitorização Transcutânea dos Gases Sanguíneos/métodos , Monitorização Transcutânea dos Gases Sanguíneos/normas , Falha de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Escala de Gravidade do Ferimento , Masculino , Pessoa de Meia-Idade , Oximetria/instrumentação , Oximetria/métodos , Oximetria/normas , Projetos Piloto , Estudos Prospectivos , Adulto Jovem
11.
Diving Hyperb Med ; 42(4): 208-13, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23258457

RESUMO

INTRODUCTION: Several studies define normal transcutaneous oximetry measurements (TCOM) for the chest and lower limb, but not the upper limb. Standardised healthy-subject reference values for upper limb TCOM would make interpretation of these measurements in disease or injury more meaningful. AIM: To determine 'normal' TCOM values for the upper limb in healthy non-smoking adults. METHOD: Thirty-two healthy volunteers (16 male, 16 female) had TCOM performed on the chest and at five upper limb positions: lateral aspect of the upper arm midway between the shoulder and elbow; lateral aspect of the forearm, dorsum of the hand, thenar and hypothenar eminences. Measurements were taken using the TCM400 Monitoring System (Radiometer) with subjects breathing room air and whilst breathing 100% oxygen. RESULTS: Room-air TCOM values (mean (SD), 95% confidence interval (CI)) were: chest: 50 (11.4) mmHg, 95% CI 46.0 to 54.2; upper arm: 53 (9.3) mmHg, 95% CI 49.7 to 56.4; forearm: 45 (11.3) mmHg, 95% CI 40.4 to 48.6; dorsum of hand: 39 (8.5) mmHg, 95% CI 35.5 to 41.7; thenar eminence: 54 (7.7) mmHg, 95% CI 51.7 to 57.2; and hypothenar eminence: 57 (7.5) mmHg, 95% CI 54.1 to 59.6. All readings showed a substantial increase when subjects breathed 100% oxygen. Using the currently accepted threshold for tissue hypoxia of < 40 mmHg, six forearm and 14 dorsum of the hand TCOM readings would have been classified as hypoxic. CONCLUSION: Normal upper limb TCOM readings are less than those established for the lower limb. Using lower-limb reference standards could result in false-positive determinations of tissue hypoxia. We recommend TCOM ≤ 30 mmHg as indicative of tissue hypoxia in the upper arm, thenar and hypothenar eminences, and < 20 mmHg in the forearm and dorsum of the hand.


Assuntos
Braço , Monitorização Transcutânea dos Gases Sanguíneos/normas , Adulto , Idoso , Ar , Hipóxia Celular/fisiologia , Feminino , Antebraço , Mãos , Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Oxigênio/administração & dosagem , Valores de Referência , Tórax
12.
J Extra Corpor Technol ; 43(2): 53-7, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21848172

RESUMO

During cardiopulmonary bypass blood gases can be analyzed with laboratory equipment or with an in-line monitor giving instant results. The manufacturer of the CDI 500 in-line blood gas monitor recommends gas calibration before use. In acute cases there may not be time to perform a gas calibration. We hypothesized that after calibration against laboratory results, the CDI values of pH, pO2, and pCO2 will keep the same level of accuracy, whether the CDI has been gas calibrated or not. We performed a prospective randomized observational study using a study group without gas calibration (29 patients) and a control group with gas calibration (29 patients). Blood sampling was done at the beginning of bypass, and 30 minutes later. After each blood sample the CDI was in-vivo calibrated to the values simultaneously obtained from the ABL. Before in-vivo calibration values from the CDI without gas calibration were significantly different from the ABL-values in accuracy as well as precision, whereas the results from the gas calibrated CDI were largely consistent with the ABL. Before in-vivo calibration, the CDI without gas calibration was completely unreliable. After in-vivo calibration there was no statistical difference between the values of the CDI with and without calibration. We recommend gas calibration of the CDI before use in the period before in-vivo calibration.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/instrumentação , Monitorização Transcutânea dos Gases Sanguíneos/normas , Calibragem , Dióxido de Carbono/sangue , Ponte Cardiopulmonar , Estudos de Casos e Controles , Circulação Extracorpórea , Humanos , Oximetria , Oxigênio/sangue , Estudos Prospectivos , Reprodutibilidade dos Testes
13.
Scand J Clin Lab Invest ; 71(7): 548-52, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21732731

RESUMO

AIM: The harmful effect of hypocapnia on the neonatal brain emphasizes the importance of monitoring arterial carbon dioxide tension (PaCO2). Transcutaneous monitoring of carbon dioxide (tcPCO2) reduces the need for arterial blood sampling. Drawbacks are high electrode temperature causing risks of skin burning. The aim was to determine the accuracy and precision of tcPCO2 at reduced electrode temperature. METHODS: Forty newborns (GA 24.9-41.7) were included. Two tc-monitors were applied (TCM4, Radiometer, Copenhagen). Arterial blood gas sampling and monitoring of tcPCO2-level at different electrode temperatures was done simultaneously (39°C, 40°C, 41°C, 42°C, 44°C). Difference of PaCO2 - tcPCO2 was expressed as a percentage of the mean. RESULTS: Mean PaCO2 was 5.8kPa [3,2; 7.9]. Bias (PaCO2 - tcPCO2) increased from 5% at 44°C to 17% at 39°C, but did not differ significantly between 41°C and 40°C. The precision of the tcPCO2 at each temperature ranged from +7-10%. After correction for the temperature-dependent overreading, we found increasing PaCO2 - tcPCO2 difference with increasing PaCO2, approx. 2% pr. kPa increase of CO(2). Only mild transient erythema was observed. CONCLUSION: A lower electrode temperature in tcPCO2-monitoring increases systematic overreading of the tc-electrode. However, in very preterm babies, monitoring at 40°C or 41°C is possible provided a bias correction of 12-15% is applied.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/métodos , Dióxido de Carbono/análise , Hipocapnia/prevenção & controle , Monitorização Transcutânea dos Gases Sanguíneos/instrumentação , Monitorização Transcutânea dos Gases Sanguíneos/normas , Eletrodos/normas , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Temperatura
14.
Ann Emerg Med ; 57(4): 330-3, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21251729

RESUMO

STUDY OBJECTIVE: Hemoglobin measurement is a routine procedure, and a noninvasive point-of-care device may increase the quality of care. The aim of the present study is to compare hemoglobin concentration values obtained with a portable totally noninvasive device, the Masimo Labs Radical-7 Pulse CO-Oximeter, with the results obtained by the ADVIA 2120 in the laboratory. METHODS: This was a prospective monocentric open trial enrolling patients consulting in the emergency department of a university hospital from June 16 to December 17, 2009. The main outcome measure was the agreement between both methods and evaluation of the percentage of potential decision error for transfusion. RESULTS: Samples from 300 consecutive patients were assessed. Hemoglobin concentration could not be obtained with the new device for 24 patients. In others, the mean bias, the lower and the upper limits of agreement between the 2 methods, was 1.8 g/dL (95% estimated confidence interval [CI] 1.5 to 2.1 g/dL), -3.3 g/dL (95% CI -3.8 to -2.8 g/dL), and 6.9 g/dL (95% CI 6.4 to 7.4 g/dL), respectively. The intraclass correlation coefficient was 0.53 (estimated 95% CI 0.10 to 0.74). The number of potential errors about transfusion decision was 38 (13% of patients). The peripheral oxygen saturation and the true value of hemoglobin concentration were independently associated with the bias. CONCLUSION: Results from this widely available noninvasive point-of-care hemoglobin monitoring device were systematically biased and too unreliable to guide transfusion decisions.


Assuntos
Hemoglobinometria/instrumentação , Hemoglobinas/análise , Adulto , Idoso , Monitorização Transcutânea dos Gases Sanguíneos/instrumentação , Monitorização Transcutânea dos Gases Sanguíneos/normas , Determinação da Pressão Arterial , Serviço Hospitalar de Emergência , Feminino , Hemoglobinometria/métodos , Hemoglobinometria/normas , Humanos , Masculino , Pessoa de Meia-Idade , Sistemas Automatizados de Assistência Junto ao Leito/normas , Pulso Arterial
15.
J Cardiothorac Vasc Anesth ; 25(2): 243-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20851636

RESUMO

OBJECTIVE: The aim of this study was to validate the revised SenTec V-Sign 2 sensor (SenTec AG, Therwil, Switzerland) for combined noninvasive continuous assessment of pulse rate, pulse oximetry (SpO(2)), and transcutaneous carbon dioxide tension (PtcCO(2)) in adults after cardiac surgery. DESIGN: A prospective clinical study. SETTING: A single-center university hospital. PARTICIPANTS: Twenty adult patients aged 36 to 84 years after cardiac surgery. INTERVENTIONS: SpO(2) and PtcCO(2) values of three V-Sign 2 sensors (SenTec AG) attached at the earlobe, forehead, and cheek and SpO(2) values of the Nellcor Durasensor (Model DS-100A; Nellcor Puritan Bennett Inc, Pleasanton, CA) were compared with simultaneous measurements of blood gases and end-expiratory carbon dioxide. MEASUREMENTS AND MAIN RESULTS: Measurements were performed during periods of hyper-, normo-, and hypocapnia and then at 30-minute intervals up to 5 hours. Bland-Altman analysis and simple regression analysis were used. RESULTS: The detection failures for PtcCO(2) were 0.3% to 1.3%, for SpO(2) 10% to 25%, and for pulse rate 5% to 10%. The V-Sign 2 earlobe sensor provided the best results. The mean bias and limits of agreement for PtcCO(2ear) and PaCO(2) were 1.1 and -3.4/+5.5 mmHg. The drift of PtcCO(2) was negligible at all locations. The mean bias and limits of agreement of V-Sign SpO(2ear) and SaO(2), as well as V-Sign pulse rate and the electrocardiogram, were -1.7% and -6.8/+3.9% and 1.2 beats/min and -3.3/+5.8 beats/min. End-expiratory carbon dioxide showed a weak correlation with PaCO(2) (r(2) = 0.47). CONCLUSIONS: Transcutaneous capnometry using the revised V-Sign 2 sensor at the earlobe is a reliable monitoring tool during the recovery period of patients after cardiac surgery. This approach has the potential to reduce the number of arterial blood gas samples.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Orelha/irrigação sanguínea , Orelha/fisiologia , Oximetria/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Gasometria/métodos , Gasometria/normas , Monitorização Transcutânea dos Gases Sanguíneos/métodos , Monitorização Transcutânea dos Gases Sanguíneos/normas , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Humanos , Hipercapnia/sangue , Hipercapnia/diagnóstico , Hipocapnia/sangue , Hipocapnia/diagnóstico , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Monitorização Fisiológica/normas , Oximetria/normas , Estudos Prospectivos
16.
Intern Med J ; 41(8): 630-3, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20214687

RESUMO

BACKGROUND: Pulse oximetry non-invasively assesses the arterial oxygen saturation of patients with acute respiratory disease; however, measurement of the arterial partial pressure of carbon dioxide (PaCO(2)) requires an arterial blood gas. The transcutaneous partial pressure of carbon dioxide (PtCO(2) ) has been used in other settings with variable accuracy. We investigated the accuracy of a PtCO(2) device in the assessment of PaCO(2) in patients with asthma and suspected pneumonia attending the emergency department. METHODS: Patients with severe asthma (FEV(1) < 50% predicted) or suspected pneumonia (fever, cough and respiratory rate >18/min) were enrolled. Subjects were excluded if they had a history of chronic obstructive pulmonary disease or other conditions associated with respiratory failure. Arterial blood gases were taken at the discretion of the investigator according to clinical need, and paired with a simultaneous reading from the PtCO(2) probe. RESULTS: Twenty-five patients were studied with one set of data excluded because of poor PtCO(2) signal quality. The remaining 24 paired samples comprised 12 asthma and 12 pneumonia patients. The range of PaCO(2) was 19-64 mmHg with a median of 36.5 mmHg. Bland-Altman analysis showed a mean (SD) PaCO(2) - PtCO(2) difference of -0.13 (1.9) mmHg with limits of agreement of plus or minus 3.8 mmHg (-3.9 to +3.7). CONCLUSION: A PtCO(2) device was accurate in the assessment of PaCO(2) in patients with acute severe asthma and suspected pneumonia when compared with an arterial blood gas. These bedside monitors have the potential to improve patient care by non-invasively monitoring patients with acute respiratory disease at risk of hypercapnia.


Assuntos
Asma/sangue , Dióxido de Carbono/sangue , Oximetria/normas , Pneumonia/sangue , Doença Aguda , Adulto , Asma/diagnóstico , Monitorização Transcutânea dos Gases Sanguíneos/métodos , Monitorização Transcutânea dos Gases Sanguíneos/normas , Infecções Comunitárias Adquiridas/sangue , Infecções Comunitárias Adquiridas/diagnóstico , Feminino , Humanos , Masculino , Oximetria/métodos , Pressão Parcial , Pneumonia/diagnóstico , Estudos Prospectivos
17.
Intensive Care Med ; 37(2): 348-51, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21069287

RESUMO

PURPOSE: Transcutaneous CO(2) monitors are widely used in neonatal ICUs. Until recently, these devices performed poorly in adults. Recent technical modifications have produced transcutaneous CO(2) monitors that have performed well in adults with chronic illnesses. We evaluated the accuracy of one of these devices, the TOSCA(®) 500, in adults admitted to an emergency department for acute respiratory failure. METHODS: We prospectively collected 29 pairs of simultaneous transcutaneous arterial CO(2) (PtcCO(2)) and arterial CO(2) (PaCO(2)) values in 21 consecutive adults with acute respiratory failure (acute heart failure, n = 6; COPD exacerbation, n = 8; acute pneumonia, n = 6; and pulmonary embolism, n = 1). Agreement between PaCO(2) and PtcCO(2) was evaluated using the Bland-Altman method. RESULTS: Mean arterial oxygen saturation was 90%, arterial oxygen tension ranged from 32 to 215 mmHg, and PaCO(2) ranged from 23 to 84 mmHg. The mean difference between PaCO(2) and PtcCO(2) was 0.1 mmHg, and the Bland-Altman limits of agreement (bias ± 1.96 SD) ranged from -6 to 6.2 mmHg. None of the patients experienced adverse effects from heating of the device clipped to the earlobe. CONCLUSION: PtcCO(2) showed good agreement with PaCO(2) in adults with acute respiratory failure.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/normas , Dióxido de Carbono/sangue , Síndrome do Desconforto Respiratório/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Serviço Hospitalar de Emergência , Feminino , França , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
18.
J Diabetes Sci Technol ; 4(5): 1269-75, 2010 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-20920450

RESUMO

Rigorous glucose control is essential for prevention of diabetes-related complications in diabetes patients. Even without diabetes, tight glucose control is beneficial in hospitalized, critically ill patients. Actually, three different glucose measurement methods are used: (1) hand held devices, (2) blood-gas analyzers, and (3) laboratory analyzers in core laboratories. Each method is subject to specific challenges and limitations that can affect the overall system performance. In this article, we aim to demonstrate that even glucose measurement results from core laboratories (professional laboratory systems) do not necessarily reflect the absolute "true" glucose level of a patient.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/métodos , Automonitorização da Glicemia/métodos , Glicemia/metabolismo , Diabetes Mellitus/sangue , Laboratórios , Monitorização Transcutânea dos Gases Sanguíneos/normas , Automonitorização da Glicemia/normas , Estado Terminal , Glucose 1-Desidrogenase , Glucose Oxidase , Hexoquinase , Humanos , Laboratórios/normas , Reprodutibilidade dos Testes
19.
J Clin Monit Comput ; 23(6): 363-8, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19876749

RESUMO

INTRODUCTION: Transcutaneous measurement of gases depends on the degree of skin perfusion. Mechanical ventilation causes alteration in the peripheral perfusion. The aim of this prospective observational study was to assess change in the accuracy of interchangeability of arterial blood gases with those obtained transcutaneously at various phases of mechanical ventilation such as controlled mandatory, synchronized intermittent mandatory, continuous positive airway pressure ventilations, spontaneous breathing trail and spontaneous ventilation after extubation of endotracheal tube. METHODS: Thirty-two adult patients who underwent uncomplicated off pump coronary artery bypass surgery in a tertiary care medical center were subjected to transcutaneous measurements of gases from the sensor placed on the chest during postoperative ventilation. Arterial blood gas analysis was performed at predetermined time intervals and transcutaneous measurements were repeated each of those time. RESULTS: Fifty-four sets of data were obtained during controlled ventilation and fifty during spontaneous. Correlation coefficient for oxygen increased from 0.46 (P = 0.0004) during controlled ventilation to 0.75 (P < 0.0001) during spontaneous. Bland-Altman and mountain plots suggested better inter- changeability of values between arterial blood gas and transcutaneous gas monitoring. The bias for oxygen changed from 21 during controlled ventilation to 25 during spontaneous ventilation and the precision from 7.1 to 6.4. There was no change in the accuracy of transcutaneous carbon dioxide values during either phase of ventilation. CONCLUSION: The accuracy of transcutaneously measured values of oxygen improved significantly during spontaneous ventilation.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/métodos , Monitorização Transcutânea dos Gases Sanguíneos/normas , Ponte de Artéria Coronária sem Circulação Extracorpórea , Respiração Artificial/métodos , Adulto , Dióxido de Carbono/sangue , Interpretação Estatística de Dados , Humanos , Oxigênio/sangue , Cuidados Pós-Operatórios , Estudos Prospectivos , Estudos Retrospectivos
20.
Undersea Hyperb Med ; 36(1): 43-53, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19341127

RESUMO

Transcutaneous oximetry (PtcO2) is finding increasing application as a diagnostic tool to assess the peri-wound oxygen tension of wounds, ulcers, and skin flaps. It must be remembered that PtcO2 measures the oxygen partial pressure in adjacent areas of a wound and does not represent the actual partial pressure of oxygen within the wound, which is extremely difficult to perform. To provide clinical practice guidelines, an expert panel was convened with participants drawn from the transcutaneous oximetry workshop held on June 13, 2007, in Maui, Hawaii. Important consensus statements were (a) tissue hypoxia is defined as a PtcO2 <40 mm Hg; (b) in patients without vascular disease, PtcO2 values on the extremity increase to a value >100 mm Hg when breathing 100% oxygen under normobaric pressures; (c) patients with critical limb ischemia (ankle systolic pressure of < or =50 mm Hg or toe systolic pressure of < or =30 mm Hg) breathing air will usually have a PtcO2 <30 mm Hg; (d) low PtcO2 values obtained while breathing normobaric air can be caused by a diffusion barrier; (e) a PtcO2 <40 mm Hg obtained while breathing normobaric air is associated with a reduced likelihood of amputation healing; (f) if the baseline PtcO2 increases <10 mm Hg while breathing 100% normobaric oxygen, this is at least 68% accurate in predicting failure of healing post-amputation; (g) an increase in PtcO2 to >40 mm Hg during normobaric air breathing after revascularization is usually associated with subsequent healing, although the increase in PtcO2 may be delayed; (h) PtcO2 obtained while breathing normobaric air can assist in identifying which patients will not heal spontaneously.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/normas , Ferimentos e Lesões/sangue , Amputação Cirúrgica , Monitorização Transcutânea dos Gases Sanguíneos/métodos , Hipóxia Celular , Técnica Delphi , Pé Diabético/sangue , Pé Diabético/terapia , Medicina Baseada em Evidências , Humanos , Oxigenoterapia Hiperbárica , Doenças Vasculares Periféricas/sangue , Cicatrização , Ferimentos e Lesões/terapia