Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.770
Filtrar
1.
Med Sci Monit ; 30: e944724, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38990791

RESUMO

BACKGROUND The BrainLab VectorVision neuronavigation system is an image-guided, frameless localization system used intraoperatively, which includes a computer workstation for viewing and analyzing operative microscopic images. This retrospective study aimed to evaluate the use of the BrainLab VectorVision infrared-based neuronavigation imaging system in 80 patients with intracranial meningioma removed surgically between 2013 and 2023. MATERIAL AND METHODS Data were retrospectively collected from 36 patients with convexity meningioma and 44 patients with parasagittal meningioma between 2013 and 2023. The surgical operation of 40 of these patients was performed with the help of neuronavigation, while the other 40 were performed without neuronavigation. Demographic data, preoperative and postoperative radiologic images, craniotomy measurements, surgical complications, and operative times of patients with and without neuronavigation were analyzed. RESULTS Using neuronavigation significantly increased surgery duration (P=0.023). In 6 patients without the use of neuronavigation, the craniotomy had to be enlarged and this resulted in superior sagittal sinus (SSS) damage (P=0.77, P=0.107). Patients for whom neuronavigation was used did not experience any sinus damage and did not require craniotomy enlargement. Postoperative epidural hematoma (EH) developed in 9 patients without navigation, whereas it developed in only 1 patient with navigation (P=0.104). Residual tumors were less common in patients using navigation (P=0.237). CONCLUSIONS The use of neuronavigation allows the incision and craniotomy to be reduced in size. Intraoperatively, it allows the surgeon to master the boundaries of the tumor and surrounding vascular structures, reducing the risk of complications. These results suggest that neuronavigation systems are an effective ancillary in meningioma surgery.


Assuntos
Neoplasias Meníngeas , Meningioma , Neuronavegação , Humanos , Meningioma/cirurgia , Meningioma/patologia , Meningioma/diagnóstico por imagem , Neuronavegação/métodos , Feminino , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Neoplasias Meníngeas/cirurgia , Adulto , Idoso , Resultado do Tratamento , Craniotomia/métodos , Cirurgia Assistida por Computador/métodos , Procedimentos Neurocirúrgicos/métodos , Complicações Pós-Operatórias/etiologia
2.
Acta Neurochir (Wien) ; 166(1): 247, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38831111

RESUMO

BACKGROUND: Radiofrequency thermorhizotomy (TRZ) is an established treatment for trigeminal neuralgia (TN). TRZ can result risky and painful in a consistent subset of patients, due to the need to perform multiple trajectories, before a successful foramen ovale cannulation. Moreover, intraoperative x-rays are required. METHOD: TRZ has been performed by using a neuronavigated stylet, before trajectory planning on a dedicated workstation. CONCLUSION: Navigated-TRZ (N-TRZ) meets the expectations of a safer and more tolerable procedure due to the use of a single trajectory, avoiding critical structures. Moreover, N-TRZ is x-ray free. Efficacy outcomes are similar to those reported in literature.


Assuntos
Neuronavegação , Rizotomia , Neuralgia do Trigêmeo , Neuralgia do Trigêmeo/cirurgia , Neuralgia do Trigêmeo/diagnóstico por imagem , Humanos , Rizotomia/métodos , Neuronavegação/métodos , Resultado do Tratamento , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Feminino , Ablação por Radiofrequência/métodos
3.
Ultrasound Med Biol ; 50(8): 1155-1166, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38789304

RESUMO

OBJECTIVE: The goal of the work described here was to develop the first neuronavigation-guided transcranial histotripsy (NaviTH) system and associated workflow for transcranial ablation. METHODS: The NaviTH system consists of a 360-element, 700 kHz transmitter-receiver-capable transcranial histotripsy array, a clinical neuronavigation system and associated equipment for patient-to-array co-registration and therapy planning and targeting software systems. A workflow for NaviTH treatments, including pre-treatment aberration correction, was developed. Targeting errors stemming from target registration errors (TREs) during the patient-to-array co-registration process, as well as focal shifts caused by skull-induced aberrations, were investigated and characterized. The NaviTH system was used in treatments of two <96 h post-mortem human cadavers and in experiments in two excised human skullcaps. RESULTS: The NaviTH was successfully used to create ablations in the cadaver brains as confirmed in post-treatment magnetic resonance imaging A total of three ablations were created in the cadaver brains, and targeting errors of 9, 3.4 and 4.4 mm were observed in corpus callosum, septum and thalamus targets, respectively. Errors were found to be caused primarily by TREs resulting from transducer tracking instrument design flaws and imperfections in the treatment workflow. Transducer tracking instrument design and workflow improvements reduced TREs to <2 mm, and skull-induced focal shifts, following pre-treatment aberration correction, were 0.3 mm. Total targeting errors of the NaviTH system following the noted improvements were 2.5 mm. CONCLUSIONS: The feasibility of using the first NaviTH system in a human cadaver model has been determined. Although accuracy still needs to be improved, the proposed system has the potential to allow for transcranial histotripsy therapies without requiring active magnetic resonance treatment guidance.


Assuntos
Cadáver , Neuronavegação , Humanos , Neuronavegação/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/cirurgia , Desenho de Equipamento , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos
4.
Brain Res ; 1838: 148989, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38723740

RESUMO

Repetitive transcranial magnetic stimulation (rTMS) to the left dorsolateral prefrontal cortex (DLPFC) is an established treatment for medication-resistant depression. Several targeting methods for the left DLPFC have been proposed including identification with resting-state functional magnetic resonance imaging (rs-fMRI) neuronavigation, stimulus coordinates based on structural MRI, or electroencephalography (EEG) F3 site by Beam F3 method. To date, neuroanatomical and neurofunctional differences among those approaches have not been investigated on healthy subjects, which are structurally and functionally unaffected by psychiatric disorders. This study aimed to compare the mean location, its dispersion, and its functional connectivity with the subgenual cingulate cortex (SGC), which is known to be associated with the therapeutic outcome in depression, of various approaches to target the DLPFC in healthy subjects. Fifty-seven healthy subjects underwent MRI scans to identify the stimulation site based on their resting-state functional connectivity and were measured their head size for targeting with Beam F3 method. In addition, we included two fixed stimulus coordinates over the DLPFC in the analysis, as recommended in previous studies. From the results, the rs-fMRI method had, as expected, more dispersed target sites across subjects and the greatest anticorrelation with the SGC, reflecting the known fact that personalized neuronavigation yields the greatest antidepressant effect. In contrast, the targets located by the other methods were relatively close together with less dispersion, and did not differ in anticorrelation with the SGC, implying their limitation of the therapeutic efficacy and possible interchangeability of them.


Assuntos
Córtex Pré-Frontal Dorsolateral , Imageamento por Ressonância Magnética , Estimulação Magnética Transcraniana , Humanos , Estimulação Magnética Transcraniana/métodos , Masculino , Adulto , Feminino , Imageamento por Ressonância Magnética/métodos , Córtex Pré-Frontal Dorsolateral/fisiologia , Adulto Jovem , Eletroencefalografia/métodos , Neuronavegação/métodos , Giro do Cíngulo/fisiologia , Giro do Cíngulo/diagnóstico por imagem , Pessoa de Meia-Idade , Córtex Pré-Frontal/fisiologia , Córtex Pré-Frontal/diagnóstico por imagem , Mapeamento Encefálico/métodos , Voluntários Saudáveis
5.
World Neurosurg ; 187: e860-e869, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38734167

RESUMO

OBJECTIVE: Despite the growing acceptance of neuronavigation in the field of neurosurgery, there is limited comparative research with contradictory results. This study aimed to compare the effectiveness (tumor resection rate and survival) and safety (frequency of neurological complications) of surgery for brain gliomas with or without neuronavigation. METHODS: This retrospective cohort study evaluated data obtained from electronic records of patients who underwent surgery for gliomas at Dr. Alejandro Dávila Bolaños Military Hospital and the Clinic Hospital of Barcelona between July 2016 and September 2022. The preoperative and postoperative clinical and radiologic characteristics were analyzed and compared according to the use of neuronavigation. RESULTS: This study included 110 patients, of whom 79 underwent surgery with neuronavigation. Neuronavigation increased gross total resection by 57% in patients in whom it was used; gross total resection was performed in 56% of patients who underwent surgery with neuronavigation as compared with 35.5% in those who underwent surgery without neuronavigation (risk ratio [RR], 1.57; P=0.056). The incidence of postoperative neurologic deficits (transient and permanent) decreased by 79% with the use of neuronavigation, (12% vs. 33.3%; RR, 0.21; P=0.0003). Neuronavigation improved survival in patients with grade IV gliomas (15 months vs. 13.8 months), but it was not statistically significant (odds ratio (OR), 0.19; P=0.13). CONCLUSIONS: Neuronavigation improved the effectiveness (greater gross total resection of tumors) and safety (fewer neurological deficits) of brain glioma surgery. However, neuronavigation does not significantly influence the survival of patients with grade IV gliomas.


Assuntos
Glioma , Neuronavegação , Complicações Pós-Operatórias , Neoplasias Supratentoriais , Humanos , Neuronavegação/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Glioma/cirurgia , Estudos Retrospectivos , Adulto , Neoplasias Supratentoriais/cirurgia , Complicações Pós-Operatórias/epidemiologia , Idoso , Estudos de Coortes , Resultado do Tratamento , Procedimentos Neurocirúrgicos/métodos , Neoplasias Encefálicas/cirurgia
6.
World Neurosurg ; 187: 236-242.e1, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38750893

RESUMO

BACKGROUND: Neuronavigation has become an essential system for brain tumor resections. It is sometimes difficult to obtain accurate registration of the neuronavigation with the patient in the prone position. Bony surface-matching registration should be more precise than skin surface-matching registration; however, it is difficult to establish bony registration with limited exposed bone. We created a new bony surface-matching method to a sectioned 3-dimensional (3D) virtual skull in a neuronavigation system and registered with a sectioned 3D skull. In this study, the bony surface-matching with sectioned 3D registration is applied to provide precise registration for brain tumor resection in the prone position. METHODS: From May 2023 to April 2024, 17 patients who underwent brain tumor resection in the prone position were enrolled. The navigation system StealthStation S8 (Medtronic, Dublin, Ireland) was used. Bony surface-matching registration with a whole 3D skull in a neuronavigation system was performed. Next, a sectioned 3D skull was made according to the surgical location to compare with the whole 3D skull registration. A phantom model was also used to validate the whole and sectioned 3D skull registration. RESULTS: Whole 3D skull registration was successful for only 2 patients (11.8%). However, sectioned 3D skull registration was successful for 16 patients (94.1%). The examinations with a phantom skull model also showed superiority of sectioned 3D skull registration to whole 3D skull registration. CONCLUSIONS: Sectioned 3D skull registration was superior to whole 3D skull registration. The sectioned 3D skull method could provide accurate registration with limited exposed bone.


Assuntos
Neoplasias Encefálicas , Imageamento Tridimensional , Neuronavegação , Crânio , Humanos , Neuronavegação/métodos , Imageamento Tridimensional/métodos , Crânio/cirurgia , Crânio/anatomia & histologia , Crânio/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Idoso , Decúbito Ventral , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/diagnóstico por imagem
7.
PLoS One ; 19(5): e0301849, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38805512

RESUMO

Spatial accuracy in electrophysiological investigations is paramount, as precise localization and reliable access to specific brain regions help the advancement of our understanding of the brain's complex neural activity. Here, we introduce a novel, multi camera-based, frameless neuronavigation technique for precise, 3-dimensional electrode positioning in awake monkeys. The investigation of neural functions in awake primates often requires stable access to the brain with thin and delicate recording electrodes. This is usually realized by implanting a chronic recording chamber onto the skull of the animal that allows direct access to the dura. Most recording and positioning techniques utilize this implanted recording chamber as a holder of the microdrive or to hold a grid. This in turn reduces the degrees of freedom in positioning. To solve this problem, we require innovative, flexible, but precise tools for neuronal recordings. We instead mount the electrode microdrive above the animal on an arch, equipped with a series of translational and rotational micromanipulators, allowing movements in all axes. Here, the positioning is controlled by infrared cameras tracking the location of the microdrive and the monkey, allowing precise and flexible trajectories. To verify the accuracy of this technique, we created iron deposits in the tissue that could be detected by MRI. Our results demonstrate a remarkable precision with the confirmed physical location of these deposits averaging less than 0.5 mm from their planned position. Pilot electrophysiological recordings additionally demonstrate the accuracy and flexibility of this method. Our innovative approach could significantly enhance the accuracy and flexibility of neural recordings, potentially catalyzing further advancements in neuroscientific research.


Assuntos
Encéfalo , Eletrodos Implantados , Animais , Encéfalo/fisiologia , Neuronavegação/métodos , Neuronavegação/instrumentação , Macaca mulatta , Imageamento Tridimensional/métodos , Imageamento Tridimensional/instrumentação , Masculino , Vigília/fisiologia , Macaca
8.
Sci Data ; 11(1): 494, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38744868

RESUMO

The standard of care for brain tumors is maximal safe surgical resection. Neuronavigation augments the surgeon's ability to achieve this but loses validity as surgery progresses due to brain shift. Moreover, gliomas are often indistinguishable from surrounding healthy brain tissue. Intraoperative magnetic resonance imaging (iMRI) and ultrasound (iUS) help visualize the tumor and brain shift. iUS is faster and easier to incorporate into surgical workflows but offers a lower contrast between tumorous and healthy tissues than iMRI. With the success of data-hungry Artificial Intelligence algorithms in medical image analysis, the benefits of sharing well-curated data cannot be overstated. To this end, we provide the largest publicly available MRI and iUS database of surgically treated brain tumors, including gliomas (n = 92), metastases (n = 11), and others (n = 11). This collection contains 369 preoperative MRI series, 320 3D iUS series, 301 iMRI series, and 356 segmentations collected from 114 consecutive patients at a single institution. This database is expected to help brain shift and image analysis research and neurosurgical training in interpreting iUS and iMRI.


Assuntos
Neoplasias Encefálicas , Bases de Dados Factuais , Imageamento por Ressonância Magnética , Imagem Multimodal , Humanos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Encéfalo/diagnóstico por imagem , Encéfalo/cirurgia , Glioma/diagnóstico por imagem , Glioma/cirurgia , Ultrassonografia , Neuronavegação/métodos
9.
Adv Tech Stand Neurosurg ; 49: 19-34, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38700678

RESUMO

Neurosurgical procedures are some of the most complex procedures in medicine and since the advent of the field, planning, performing, and learning them has challenged the neurosurgeon. Virtual reality (VR) and augmented reality (AR) are making these challenges more manageable. VR refers to a virtual digital environment that can be experienced usually through use of stereoscopic glasses and controllers. AR, on the other hand, fuses the natural environment with virtual images, such as superimposing a preoperative MRI image on to the surgical field [1]. They initially were used primarily as neuronavigational tools but soon their potential in other areas of surgery, such as planning, education, and assessment, was noted and explored. Through this chapter, we outline the history and evolution of these two technologies over the past few decades, describe the current state of the technology and its uses, and postulate future directions for research and implementation.


Assuntos
Realidade Aumentada , Procedimentos Neurocirúrgicos , Realidade Virtual , Humanos , Procedimentos Neurocirúrgicos/métodos , Criança , Neurocirurgia/métodos , Pediatria/métodos , Neuronavegação/métodos
10.
J Clin Neurosci ; 123: 203-208, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38608532

RESUMO

OBJECTIVE: Neuronavigation is common technology used by skull base teams when performing endoscopic endonasal surgery. A common practice of MRI imagining is to obtain 3D isotopic gadolinium enhanced T1W magnetisation prepared rapid gradient echo (MPRAGE) sequences. These are prone to distortion when undertaken on 3 T magnets. The aim of this project is to compare the in vivo accuracy of MRI sequences between current and new high resolution 3D sequences. The goal is to determine if geometric distortion significantly affects neuronavigation accuracy. METHODS: Patients were scanned with a 3D T1 MPRAGE sequence, 3D T1 SPACE sequence and a CT stereotactic localisation. Following general anaesthesia, patients were registered on the Stealth Station (Medtronic, USA) using a side mount emitter for Electromagnetic navigation. A variety of surgically relevant anatomical landmarks in the sagittal and coronal plane were selected with real and virtual data points measured. RESULTS: A total of 10 patients agreed be enrolled in the study with datapoints collected during surgery. The distance between real and virtual datapoints trended to be lower in SPACE sequences compared to MPRAGE. Paired t test did not demonstrate a significant difference. CONCLUSION: We have demonstrated that navigational accuracy is not significantly affected by the type of MRI sequence selected and that current corrective algorithms are sufficient. Navigational accuracy is affected by many factors, with registration error likely playing the most significant role. Further research involving real time imaging such as endoscopic ultrasound may hopefully address this potential error.


Assuntos
Imageamento por Ressonância Magnética , Neuronavegação , Base do Crânio , Humanos , Neuronavegação/métodos , Imageamento por Ressonância Magnética/métodos , Base do Crânio/cirurgia , Base do Crânio/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Imageamento Tridimensional/métodos , Neuroendoscopia/métodos , Idoso
11.
J Neurosurg Pediatr ; 34(1): 19-29, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38669716

RESUMO

OBJECTIVE: Language dominance in the developing brain can vary widely across anatomical and pathological conditions as well as age groups. Repetitive navigated transcranial magnetic stimulation (rnTMS) has been applied to calculate the hemispheric dominance ratio (HDR) in adults. In this study, the authors aimed to assess the feasibility of using rnTMS to identify language lateralization in a pediatric neurosurgical cohort and to correlate the preoperative rnTMS findings with the postoperative language outcome. METHODS: A consecutive prospectively collected cohort of 19 children with language-associated lesions underwent bihemispheric rnTMS mapping prior to surgery (100 stimulation sites on each hemisphere). In addition to feasibility and adverse effects, the HDR (ratio of the left hemisphere to right hemisphere error rate) was calculated. The anatomical surgical site and postoperative language outcome at 3 months after surgery were assessed according to clinical documentation. RESULTS: Repetitive nTMS mapping was feasible in all 19 children (mean age 12.5 years, range 4-17 years; 16 left-sided lesions) without any relevant adverse events. Thirteen children (68%) showed left hemispheric dominance (HDR > 1.1), and 2 children (11%) showed right hemispheric dominance (HDR < 0.9). In 4 children (21%), the bihemispheric error rates were nearly the same (HDR ≥ 0.9 and ≤ 1.1). Sixteen children underwent surgery (14 tumor/lesion resections and 2 hemispherotomies) and 3 patients continued conservative therapy. After surgery, 4 patients (25%) showed an improvement in language function, 10 (63%) presented with stable language function, and 2 (12.5%) experienced deterioration in language function. Of the 6 patients with right hemispheric language involvement, 4 (80%) had glial tumors, 1 (20%) had focal cortical dysplasia, and 1 (20%) experienced hypoxic brain injury. Children with right hemispheric language involvement (HDR ≤ 1.1) did not show any language deterioration postoperatively. CONCLUSIONS: Bihemispheric rnTMS language mapping as a noninvasive mapping technique to assess lateralization of language function in the pediatric neurosurgical population is safe and feasible. Why relevant right hemispheric language function (HDR ≤ 1.1) was associated with postoperative unaltered language function needs to be validated in future studies. Bihemispheric rnTMS language mapping strengthens risk-benefit considerations prior to pediatric tumor/epilepsy surgery in language-associated areas.


Assuntos
Neuronavegação , Estimulação Magnética Transcraniana , Humanos , Criança , Masculino , Feminino , Adolescente , Pré-Escolar , Estimulação Magnética Transcraniana/métodos , Neuronavegação/métodos , Estudos Prospectivos , Idioma , Lateralidade Funcional/fisiologia , Mapeamento Encefálico/métodos , Neoplasias Encefálicas/cirurgia , Estudos de Viabilidade , Procedimentos Neurocirúrgicos/métodos , Resultado do Tratamento
12.
World Neurosurg ; 187: 19-28, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38583569

RESUMO

BACKGROUND: Ventriculoscopic neuronavigation has been described in several articles. However, there are different ventriculoscopes and navigation systems. Due to these different combinations, it is difficult to find detailed neuronavigation protocols. We describe, step-by-step, a simple method to navigate both the trajectory until reaching the ventricular system, as well as the intraventricular work. METHODS: We use a rigid ventriculoscope (LOTTA, KarlStorz) with an electromagnetic stylet (S8-StealthSystem, Medtronic). The protocol is based on a modified or 3-dimensionally printed trocar for navigating the extraventricular step and on a modified pediatric nasogastric tube for the intraventricular navigation. RESULTS: This protocol can be set up in less than 10 minutes. The extraventricular part is navigated by introducing the electromagnetic stylet inside the modified or 3-dimensionally printed trocar. Intraventricular navigation is done by combining a modified pediatric nasogastric tube with the electromagnetic stylet inside the endoscope's working channel. The most critical point is to obtain a blunt-bloodless ventriculostomy while achieving perfect alignment of all targeted structures via pure straight trajectories. CONCLUSIONS: This protocol is easy-to-set-up, avoids head rigid-fixation and bulky optical-based attachments to the ventriculoscope, and allows continuous navigation of both parts of the surgery. Since we have implemented this protocol, we have noticed a significant enhancement in both simple and complex ventriculoscopic procedures because the surgery is dramatically simplified.


Assuntos
Neuroendoscópios , Neuroendoscopia , Neuronavegação , Ventriculostomia , Fluxo de Trabalho , Humanos , Neuronavegação/métodos , Neuronavegação/instrumentação , Neuroendoscopia/métodos , Neuroendoscopia/instrumentação , Ventriculostomia/métodos , Ventriculostomia/instrumentação , Fenômenos Eletromagnéticos , Impressão Tridimensional
13.
Clin Neurol Neurosurg ; 240: 108269, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38593567

RESUMO

OBJECTIVE: The V3 segment of the vertebral artery (V3-VA) is at risk during diverse approaches to the craniovertebral junction. Our objective is to present a system of anatomic and topographic landmarks to identify the V3-VA during the paramedian suboccipital approach (PMSOA) with the help of minimal or basic tools. MATERIAL AND METHODS: The first was a retrospective analysis of the angiotomography (CTA) of 50 patients over 18-years old, and 9 anatomical dissections. A series of lines were defined between the different bony landmarks. Within this lines the risk area of the vertebral artery (RAsV3-VA) and the risk point of the vertebral artery (RPsV3-VA) were defined. The second stage was a prospective study, where the previously defined measurements were carried out by using neuronavigation in 10 patients (20 sides) operated with the PMSO approach in order to confirm the presence of the V3 segment in the RAsV3-VA and RPsV3-VA. RESULTS: In the first stage, the V3 segment was found in the middle third of the X line in 96,6% of the cases. The distance between the inion and the UCP (percentile 5) was 20 mm and to the LCP (percentile 95) was 40 mm. In the range between the UCP and the LCP, in the middle third of the inion-mastoid line (RAsV3-VA), we found 90% of the V3-VA. The measurements taken during the second stage revealed that the artery was in the middle third of the X line in 97% of the cases. 85% of the patients presented the total of the V3s-VA on the RAsV3-VA and in 85% there was a direct relationship with the V3 segment and the RPV3s-VA. CONCLUSION: We propose an easy-to-implement system to delimit the risk area of the V3-VA during the PMSOA. We believe that these landmarks provide a practical, reliable, costless and useful tool that could decrease the risk of lesion of the V3-VA during this approach without the need of using.


Assuntos
Artéria Vertebral , Humanos , Artéria Vertebral/anatomia & histologia , Artéria Vertebral/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Estudos Retrospectivos , Idoso , Estudos Prospectivos , Adolescente , Adulto Jovem , Procedimentos Neurocirúrgicos/métodos , Neuronavegação/métodos
14.
Clin Neurol Neurosurg ; 241: 108292, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38657327

RESUMO

OBJECTIVE: Accurate localization and real-time guidance technologies for cerebral hematomas are essential for minimally invasive procedures, including minimally invasive hematoma puncture and drainage, as well as neuroendoscopic-assisted hematoma removal. This study aims to evaluate the precision and safety of a self-developed laser-guided device in localizing and guiding hematoma punctures in minimally invasive surgery for intracerebral hemorrhage (ICH). METHODS: We present the components of the device and its operational procedures. Subsequently, surgeons with different titles conduct hematoma puncture experiments using the device on skull models, comparing it to freehand puncture methods and recording the offset distance from the puncture needle tip to the hematoma center. Additionally, we report the application of this device in 10 patients with ICH, assessing its accuracy and safety in comparison with a neuro-navigation system. RESULTS: In simulated puncture experiments, the accuracy of the laser-guided group surpasses that of the freehand puncture group, with a significant statistical difference observed between the two groups (P < 0.05). In the laser-guided group, there is no statistically significant difference in puncture accuracy among the surgeons (P > 0.05). In clinical experiments, no relevant surgical complications were observed. The offset distance for the laser-guided group was 0.61 ± 0.18 cm, while the neuro-navigation group was 0.48 ± 0.13 cm. There was no statistically significant difference between the two groups in terms of offset distance (P > 0.05). However, there was a significant difference in surgical duration (P < 0.05), with the former being 35.0 ± 10.5 minutes and the latter being 63.8 ± 10.5 minutes. CONCLUSION: The current study describes satisfactory results from both simulated experiments and clinical applications, achieved through the use of a novel laser-guided hematoma puncture device. Furthermore, owing to its portability, affordability, and simplicity, it holds significant importance in advancing surgical interventions for ICH, especially in underdeveloped regions.


Assuntos
Hemorragia Cerebral , Punções , Humanos , Hemorragia Cerebral/cirurgia , Hemorragia Cerebral/diagnóstico por imagem , Punções/métodos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Hematoma/cirurgia , Hematoma/diagnóstico por imagem , Lasers , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Neuronavegação/métodos , Procedimentos Neurocirúrgicos/métodos
15.
World Neurosurg ; 186: e721-e726, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38616028

RESUMO

OBJECTIVE: Neuronavigation systems coupled with previously reported external anatomical landmarks assist neurosurgeons during intracranial procedures. We aimed to verify whether the posterior auricularis muscle (PAM) could be used as an external landmark for identifying the sigmoid sinus (SS) and the transverse-sigmoid sinus junction (TSSJ) during posterior cranial fossa surgery. METHODS: The PAM was dissected in 10 adult cadaveric heads and after drilling the underlying bone, the relationships with the underlying SS and TSSJ were noted. The width and length of the PAM, and the distance between the muscle and reference points (asterion, mastoid tip, and midline), were measured. RESULTS: The PAM was identified in 18 sides (9 left, 9 right). The first 20 mm of the muscle length (mean 28.28 mm) consistently overlay the mastoid process anteriorly and the proximal half of the SS slightly posteriorly on all sides. The superior border was a mean of 2.22 mm inferior to the TSSJ and, especially when the muscle length exceeded 20 mm, this border extended closer to the transverse sinus; it was usually found at a mean of 3.11 mm (range 0.0-13.80 mm) inferior to the distal third of the transverse sinus. CONCLUSIONS: Superficial landmarks give surgeons improved surgical access, avoiding overexposure of deep neurovascular structures and reducing brain retraction. On the basis of our cadaveric study, the PAM is a reliable and accurate direct landmark for identifying the SS and TSSJ. The PAM could potentially be used for guiding the retrosigmoid approach.


Assuntos
Pontos de Referência Anatômicos , Cadáver , Cavidades Cranianas , Humanos , Cavidades Cranianas/anatomia & histologia , Cavidades Cranianas/cirurgia , Pontos de Referência Anatômicos/anatomia & histologia , Fossa Craniana Posterior/anatomia & histologia , Fossa Craniana Posterior/cirurgia , Neuronavegação/métodos , Masculino , Feminino , Processo Mastoide/anatomia & histologia , Processo Mastoide/cirurgia , Procedimentos Neurocirúrgicos/métodos , Idoso
16.
World Neurosurg ; 185: e1207-e1215, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38519017

RESUMO

BACKGROUND: Gliomas adjacent to the corticospinal tract (CST) should be carefully resected to preserve motor function while achieving maximal surgical resection. Modern high-field intraoperative magnetic resonance imaging (iMRI) enables precise visualization of the residual tumor and intraoperative tractography. We prospectively evaluated the extent of resection and distance between the tumor resection cavity and CST using 3-T iMRI combined with motor evoked potentials (MEP) in glioma surgery. METHODS: Participants comprised patients who underwent surgery for solitary supratentorial glioma located within 10 mm of the CST. All cases underwent surgery using neuronavigation with overlaid CST under MEP monitoring. The correlation between distance from CST and transcortical MEP amplitude was calculated using Spearman rank correlation. RESULTS: Among the 63 patients who underwent surgery, 27 patients were enrolled in the study. Gross total resections were achieved in 26 of the 27 cases. Volumetric analysis showed the extent of resection was 98.6%. Motor function was stable or improved in 24 patients (Stable/Improved group) and deteriorated in 3 patients (Deteriorated group). All patients in the Deteriorated group showed motor deficit before surgery. Mean intraoperative minimal distance was significantly longer in the Stable/Improved group (7.3 mm) than in the Deteriorated group (1.1 mm; P < 0.05). MEP amplitude correlated with minimal distance between the resection cavity and CST (R = 0.64). CONCLUSIONS: Resection of gliomas adjacent to CST with a navigation system using 3-T iMRI could result in an ultimate EOR >98%. The combination of intraoperative tractography and MEP contributes to maximal removal of motor-eloquent gliomas.


Assuntos
Potencial Evocado Motor , Glioma , Imageamento por Ressonância Magnética , Neuronavegação , Tratos Piramidais , Humanos , Tratos Piramidais/diagnóstico por imagem , Tratos Piramidais/cirurgia , Glioma/cirurgia , Glioma/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Imageamento por Ressonância Magnética/métodos , Idoso , Potencial Evocado Motor/fisiologia , Neuronavegação/métodos , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/diagnóstico por imagem , Procedimentos Neurocirúrgicos/métodos , Estudos Prospectivos , Adulto Jovem , Monitorização Intraoperatória/métodos , Monitorização Neurofisiológica Intraoperatória/métodos , Neoplasias Supratentoriais/cirurgia , Neoplasias Supratentoriais/diagnóstico por imagem
17.
No Shinkei Geka ; 52(2): 248-253, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38514113

RESUMO

Recently, three-dimensional(3D)holograms from mixed-reality(MR)devices have become available in the medical field. 3D holographic images can provide immersive and intuitive information that has been reported to be very useful for preoperative simulations. Compared with conventional 3D images on a two-dimensional(2D)monitor, 3D holograms offer a higher level of realism, allowing observation of the images anytime and anywhere if the MR device is operational. Even during surgery, surgeons can check realistic 3D holograms in front of them, above the surgical field, without having to turn their heads toward a 2D monitor on the wall. 3D holograms can also be used for neuronavigation if the hologram is tracked to the patient's real head. This method can be defined as 3D augmented reality(AR)navigation, which shows a hologram of a target, such as a tumor or aneurysm, inside the head and brain. In the future, interventions using these techniques with 3D holograms from MR devices are expected to evolve and develop new types of treatments for endoscopic surgery or fluoroscopy-guided endovascular surgery.


Assuntos
Realidade Aumentada , Holografia , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Neuronavegação/métodos , Imageamento Tridimensional/métodos , Holografia/métodos
18.
BMC Surg ; 24(1): 86, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38475783

RESUMO

OBJECTIVE: To compare neuronavigation-assisted intracerebral hematoma puncture and drainage with neuroendoscopic hematoma removal for treatment of hypertensive cerebral hemorrhage. METHOD: Ninety-one patients with hypertensive cerebral hemorrhage admitted to our neurosurgery department from June 2022 to May 2023 were selected: 47 patients who underwent endoscopic hematoma removal with the aid of neuronavigation in observation Group A and 44 who underwent intracerebral hematoma puncture and drainage in control Group B. The duration of surgery, intraoperative bleeding, hematoma clearance rate, pre- and postoperative GCS score, National Institutes of Health Stroke Scale (NIHSS) score, mRS score and postoperative complications were compared between the two groups. RESULTS: The duration of surgery, intraoperative bleeding and hematoma clearance were significantly lower in Group B than in Group A (p < 0.05). Conversely, no significant differences in the preoperative, 7-day postoperative, 14-day postoperative or 1-month postoperative GCS or NIHSS scores or the posthealing mRS score were observed between Groups A and B. However, the incidence of postoperative complications was significantly greater in Group B than in Group A (p < 0.05), with the most significant difference in incidence of intracranial infection (p < 0.05). CONCLUSION: Both neuronavigation-assisted intracerebral hematoma puncture and drainage and neuroendoscopic hematoma removal are effective at improving the outcome of patients with hypertensive cerebral hemorrhage. The disadvantage of neuronavigation is that the incidence of complications is significantly greater than that of other methods; postoperative care and prevention of complications should be strengthened in clinical practice.


Assuntos
Hemorragia Intracraniana Hipertensiva , Neuroendoscopia , Humanos , Neuronavegação/métodos , Hemorragia Intracraniana Hipertensiva/cirurgia , Paracentese , Resultado do Tratamento , Drenagem/métodos , Neuroendoscopia/métodos , Hematoma/cirurgia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos
19.
Childs Nerv Syst ; 40(6): 1681-1688, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38441630

RESUMO

BACKGROUND AND OBJECTIVES: Robot-assisted biopsies have gained popularity in the last years. Most robotic procedures are performed with a floor-based robotic arm. Recently, Medtronic Stealth Autoguide, a miniaturized robotic arm that work together with an optical neuronavigation system, was launched. Its application in pediatric cases is relatively unexplored. In this study, we retrospectively report our experience using the Stealth Autoguide, for frameless stereotactic biopsies in pediatric patients. METHODS: Pediatric patients who underwent stereotactic biopsy using the Stealth Autoguide cranial robotic platform from July 2020 to May 2023 were included in this study. Clinical, neuroradiological, surgical, and histological data were collected and analyzed. RESULTS: Nineteen patients underwent 20 procedures (mean age was 9-year-old, range 1-17). In four patients, biopsy was part of a more complex surgical procedure (laser interstitial thermal therapy - LITT). The most common indication was diffuse intrinsic brain stem tumor, followed by diffuse supratentorial tumor. Nine procedures were performed in prone position, eight in supine position, and three in lateral position. Facial surface registration was adopted in six procedures, skull-fixed fiducials in 14. The biopsy diagnostic tissue acquisition rate was 100% in the patients who underwent only biopsy, while in the biopsy/LITT group, one case was not diagnostic. No patients developed clinically relevant postoperative complications. CONCLUSION: The Stealth Autoguide system has proven to be safe, diagnostic, and highly accurate in performing stereotactic biopsies for both supratentorial and infratentorial lesions in the pediatric population.


Assuntos
Biópsia Guiada por Imagem , Procedimentos Cirúrgicos Robóticos , Humanos , Criança , Masculino , Feminino , Pré-Escolar , Adolescente , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Estudos Retrospectivos , Biópsia Guiada por Imagem/instrumentação , Biópsia Guiada por Imagem/métodos , Lactente , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/diagnóstico por imagem , Neuronavegação/métodos , Neuronavegação/instrumentação , Técnicas Estereotáxicas/instrumentação
20.
Medicina (Kaunas) ; 60(2)2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38399622

RESUMO

Background and Objectives: To investigate the role of augmented reality (AR) in skull base (SB) neurosurgery. Materials and Methods: Utilizing PRISMA methodology, PubMed and Scopus databases were explored to extract data related to AR integration in SB surgery. Results: The majority of 19 included studies (42.1%) were conducted in the United States, with a focus on the last five years (77.8%). Categorization included phantom skull models (31.2%, n = 6), human cadavers (15.8%, n = 3), or human patients (52.6%, n = 10). Microscopic surgery was the predominant modality in 10 studies (52.6%). Of the 19 studies, surgical modality was specified in 18, with microscopic surgery being predominant (52.6%). Most studies used only CT as the data source (n = 9; 47.4%), and optical tracking was the prevalent tracking modality (n = 9; 47.3%). The Target Registration Error (TRE) spanned from 0.55 to 10.62 mm. Conclusion: Despite variations in Target Registration Error (TRE) values, the studies highlighted successful outcomes and minimal complications. Challenges, such as device practicality and data security, were acknowledged, but the application of low-cost AR devices suggests broader feasibility.


Assuntos
Realidade Aumentada , Neurocirurgia , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Neuronavegação/métodos , Base do Crânio/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA