1.
Sensors (Basel) ; 24(9)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38732804

RESUMO

In general, it is difficult to visualize internal ocular structure and detect a lesion such as a cataract or glaucoma using the current ultrasound brightness-mode (B-mode) imaging. This is because the internal structure of the eye is rich in moisture, resulting in a lack of contrast between tissues in the B-mode image, and the penetration depth is low due to the attenuation of the ultrasound wave. In this study, the entire internal ocular structure of a bovine eye was visualized in an ex vivo environment using the compound acoustic radiation force impulse (CARFI) imaging scheme based on the phase-inverted ultrasound transducer (PIUT). In the proposed method, the aperture of the PIUT is divided into four sections, and the PIUT is driven by the out-of-phase input signal capable of generating split-focusing at the same time. Subsequently, the compound imaging technique was employed to increase signal-to-noise ratio (SNR) and to reduce displacement error. The experimental results demonstrated that the proposed technique could provide an acoustic radiation force impulse (ARFI) image of the bovine eye with a broader depth-of-field (DOF) and about 80% increased SNR compared to the conventional ARFI image obtained using the in-phase input signal. Therefore, the proposed technique can be one of the useful techniques capable of providing the image of the entire ocular structure to diagnose various eye diseases.


Assuntos
Técnicas de Imagem por Elasticidade , Olho , Razão Sinal-Ruído , Transdutores , Animais , Bovinos , Olho/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia/métodos
2.
J Radiol Prot ; 44(2)2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38701771

RESUMO

Given the new recommendations for occupational eye lens doses, various lead glasses have been used to reduce irradiation of interventional radiologists. However, the protection afforded by lead glasses over prescription glasses (thus over-glasses-type eyewear) has not been considered in detail. We used a phantom to compare the protective effects of such eyewear and regular eyewear of 0.07 mm lead-equivalent thickness. The shielding rates behind the eyewear and on the surface of the left eye of an anthropomorphic phantom were calculated. The left eye of the phantom was irradiated at various angles and the shielding effects were evaluated. We measured the radiation dose to the left side of the phantom using RPLDs attached to the left eye and to the surface/back of the left eyewear. Over-glasses-type eyewear afforded good protection against x-rays from the left and below; the average shielding rates on the surface of the left eye ranged from 0.70-0.72. In clinical settings, scattered radiation is incident on physicians' eyes from the left and below, and through any gap in lead glasses. Over-glasses-type eyewear afforded better protection than regular eyewear of the same lead-equivalent thickness at the irradiation angles of concern in clinical settings. Although clinical evaluation is needed, we suggest over-glasses-type Pb eyewear even for physicians who do not wear prescription glasses.


Assuntos
Dispositivos de Proteção dos Olhos , Óculos , Exposição Ocupacional , Doses de Radiação , Proteção Radiológica , Humanos , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/análise , Imagens de Fantasmas , Olho/efeitos da radiação , Lesões por Radiação/prevenção & controle
3.
Int J Mol Sci ; 25(9)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38731972

RESUMO

Vaccination is a public health cornerstone that protects against numerous infectious diseases. Despite its benefits, immunization implications on ocular health warrant thorough investigation, particularly in the context of vaccine-induced ocular inflammation. This review aimed to elucidate the complex interplay between vaccination and the eye, focusing on the molecular and immunological pathways implicated in vaccine-associated ocular adverse effects. Through an in-depth analysis of recent advancements and the existing literature, we explored various mechanisms of vaccine-induced ocular inflammation, such as direct infection by live attenuated vaccines, immune complex formation, adjuvant-induced autoimmunity, molecular mimicry, hypersensitivity reactions, PEG-induced allergic reactions, Type 1 IFN activation, free extracellular RNA, and specific components. We further examined the specific ocular conditions associated with vaccination, such as uveitis, optic neuritis, and retinitis, and discussed the potential impact of novel vaccines, including those against SARS-CoV-2. This review sheds light on the intricate relationships between vaccination, the immune system, and ocular tissues, offering insights into informed discussions and future research directions aimed at optimizing vaccine safety and ophthalmological care. Our analysis underscores the importance of vigilance and further research to understand and mitigate the ocular side effects of vaccines, thereby ensuring the continued success of vaccination programs, while preserving ocular health.


Assuntos
Vacinação , Humanos , Vacinação/efeitos adversos , Vacinação/métodos , Vacinas contra COVID-19/imunologia , Vacinas contra COVID-19/efeitos adversos , Olho/imunologia , SARS-CoV-2/imunologia , COVID-19/prevenção & controle , COVID-19/imunologia , Vacinas/efeitos adversos , Vacinas/imunologia , Animais , Oftalmopatias/imunologia , Oftalmopatias/prevenção & controle
4.
BMC Genomics ; 25(1): 431, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38693480

RESUMO

Ophthalmic manifestations have recently been observed in acute and post-acute complications of COVID-19 caused by SARS-CoV-2 infection. Our precious study has shown that host RNA editing is linked to RNA viral infection, yet ocular adenosine to inosine (A-to-I) RNA editing during SARS-CoV-2 infection remains uninvestigated in COVID-19. Herein we used an epitranscriptomic pipeline to analyze 37 samples and investigate A-to-I editing associated with SARS-CoV-2 infection, in five ocular tissue types including the conjunctiva, limbus, cornea, sclera, and retinal organoids. Our results revealed dramatically altered A-to-I RNA editing across the five ocular tissues. Notably, the transcriptome-wide average level of RNA editing was increased in the cornea but generally decreased in the other four ocular tissues. Functional enrichment analysis showed that differential RNA editing (DRE) was mainly in genes related to ubiquitin-dependent protein catabolic process, transcriptional regulation, and RNA splicing. In addition to tissue-specific RNA editing found in each tissue, common RNA editing was observed across different tissues, especially in the innate antiviral immune gene MAVS and the E3 ubiquitin-protein ligase MDM2. Analysis in retinal organoids further revealed highly dynamic RNA editing alterations over time during SARS-CoV-2 infection. Our study thus suggested the potential role played by RNA editing in ophthalmic manifestations of COVID-19, and highlighted its potential transcriptome impact, especially on innate immunity.


Assuntos
COVID-19 , Edição de RNA , SARS-CoV-2 , Humanos , COVID-19/genética , COVID-19/virologia , SARS-CoV-2/genética , Adenosina/metabolismo , Inosina/metabolismo , Inosina/genética , Transcriptoma , Olho/metabolismo , Olho/virologia
5.
J Clin Invest ; 134(9)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38690727

RESUMO

Careful regulation of the complement system is critical for enabling complement proteins to titrate immune defense while also preventing collateral tissue damage from poorly controlled inflammation. In the eye, this balance between complement activity and inhibition is crucial, as a low level of basal complement activity is necessary to support ocular immune privilege, a prerequisite for maintaining vision. Dysregulated complement activation contributes to parainflammation, a low level of inflammation triggered by cellular damage that functions to reestablish homeostasis, or outright inflammation that disrupts the visual axis. Complement dysregulation has been implicated in many ocular diseases, including glaucoma, diabetic retinopathy, and age-related macular degeneration (AMD). In the last two decades, complement activity has been the focus of intense investigation in AMD pathogenesis, leading to the development of novel therapeutics for the treatment of atrophic AMD. This Review outlines recent advances and challenges, highlighting therapeutic approaches that have advanced to clinical trials, as well as providing a general overview of the complement system in the posterior segment of the eye and selected ocular diseases.


Assuntos
Ativação do Complemento , Proteínas do Sistema Complemento , Degeneração Macular , Humanos , Degeneração Macular/imunologia , Degeneração Macular/patologia , Proteínas do Sistema Complemento/imunologia , Proteínas do Sistema Complemento/metabolismo , Ativação do Complemento/imunologia , Animais , Olho/imunologia , Olho/patologia
7.
Skin Res Technol ; 30(5): e13719, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38696230

RESUMO

BACKGROUND: The assessment of skin aging through skin measurements faces limitations, making perceived age evaluation a more valuable and direct tool for assessing skin aging. Given that the aging process markedly affects the appearance of the eye contour, characterizing the eye region could be beneficial for perceived age assessment. This study aimed to analyze age-correlated changes in the eye contour within the Chinese Han female population and to develop, validate, and apply a multiple linear regression model for predicting perceived age. MATERIALS AND METHODS: A naïve panel of 107 Chinese women assessed the perceived ages of 212 Chinese Han women. Instrumental analysis evaluated periorbital parameters, including palpebral fissure width (PFW), palpebral fissure height (PFH), acclivity of palpebral fissure (AX), angle of inner canthal (AEN), and angle of outer canthal (AEX). These parameters were used to construct a multiple linear regression model for predicting the perceived ages of Chinese Han women. A combined treatment using Fotona 4D and an anti-aging eye cream, formulated with plant extracts, peptides, and antioxidants, was conducted to verify the cream's anti-aging efficacy and safety. This eye cream was then tested in a large-scale clinical trial involving 101 participants. The prediction model was employed in this trial to assess the perceived ages of the women after an 8-week application of the eye cream. RESULTS: All parameters were observed to decrease with age. An intergroup comparison indicated that eyelid aging in Chinese Han women accelerates beyond the age of 50. Consequently, a linear regression model was constructed and validated, with the perceived age being calculated as 183.159 - 1.078 * AEN - 4.487 * PFW + 6.061 * PFH - 1.003 * AX - 0.328 * AEX. The anti-aging efficacy and safety of the eye cream were confirmed through combined treatment with Fotona 4D, showing improvements in wrinkles, elasticity, and dark circles under the eyes. In a large-scale clinical evaluation using this eye cream, a perceived age prediction model was applied, suggesting that 8 weeks of use made participants appear 2.25 years younger. CONCLUSION: Our study developed and validated a multiple linear regression model to predict the perceived age of Chinese Han women. This model was successfully utilized in a large-scale clinical evaluation of anti-aging eye cream, revealing that 8 weeks of usage made participants appear 2.25 years younger. This method effectively bridges the gap between clinical research and consumer perceptions, explores the complex factors influencing perceived age, and aims to improve anti-aging formulations.


Assuntos
Povo Asiático , Envelhecimento da Pele , Humanos , Feminino , Envelhecimento da Pele/efeitos dos fármacos , Envelhecimento da Pele/fisiologia , Envelhecimento da Pele/etnologia , Pessoa de Meia-Idade , Adulto , Idoso , China/etnologia , Adulto Jovem , Extratos Vegetais/farmacologia , Extratos Vegetais/uso terapêutico , Creme para a Pele/administração & dosagem , Modelos Lineares , Olho , População do Leste Asiático
8.
Yale J Biol Med ; 97(1): 41-48, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38559457

RESUMO

The intricate steps of human ocular embryology are impacted by cellular and genetic signaling pathways and a myriad of external elements that can affect pregnancy, such as environmental, metabolic, hormonal factors, medications, and intrauterine infections. This review focuses on presenting some of these factors to recognize the multifactorial nature of ocular development and highlight their clinical significance. This review is based on English-language articles sourced from PubMed, Web of Science, and Google Scholar; keywords searched included "ocular development in pregnancy," "ocular embryology," "maternal nutrition," "ophthalmic change," and "visual system development." While some animal models show the disruption of ocular embryology from these external factors, there are limited post-birth assessments in human studies. Much remains unknown about the precise mechanisms of how these external factors can disrupt normal ocular development in utero, and more significant research is needed to understand the pathophysiology of these disruptive effects further. Findings in this review emphasize the importance of additional research in understanding the dynamic association between factors impacting gestation and neonatal ocular development, particularly in the setting of limited resources.


Assuntos
Olho , Exposição Materna , Animais , Feminino , Humanos , Recém-Nascido , Gravidez , Olho/embriologia
9.
Transl Vis Sci Technol ; 13(4): 4, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38564200

RESUMO

Purpose: Establishing a development environment for machine learning is difficult for medical researchers because learning to code is a major barrier. This study aimed to improve the accuracy of a postoperative vault value prediction model for implantable collamer lens (ICL) sizing using machine learning without coding experience. Methods: We used Orange data mining, a recently developed open-source, code-free machine learning tool. This study included eye-pair data from 294 patients from the B&VIIT Eye Center and 26 patients from Kim's Eye Hospital. The model was developed using OCULUS Pentacam data from the B&VIIT Eye Center and was internally evaluated through 10-fold cross-validation. External validation was performed using data from Kim's Eye Hospital. Results: The machine learning model was successfully trained using the data collected without coding. The random forest showed mean absolute errors of 124.8 µm and 152.4 µm for the internal 10-fold cross-validation and the external validation, respectively. For high vault prediction (>750 µm), the random forest showed areas under the curve of 0.725 and 0.760 for the internal and external validation datasets, respectively. The developed model performed better than the classic statistical regression models and the Google no-code platform. Conclusions: Applying a no-code machine learning tool to our ICL implantation datasets showed a more accurate prediction of the postoperative vault than the classic regression and Google no-code models. Translational Relevance: Because of significant bias in measurements and surgery between clinics, the no-code development of a customized machine learning nomogram will improve the accuracy of ICL implantation.


Assuntos
Olho , Lentes Intraoculares , Humanos , Estudos Retrospectivos , Aprendizado de Máquina , Projetos de Pesquisa
10.
Transl Vis Sci Technol ; 13(4): 7, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38568607

RESUMO

Purpose: To assess the agreement of retinoscope-based peripheral refraction techniques with the criterion standard open-field autorefractor. Methods: Fifty young adults (mean age, 24 ± 3 years) participated in this study. Two masked, experienced senior examiners carried out central refraction and peripheral refraction at the temporal 22° (T22°) and nasal 22° (N22°) eccentricities. Peripheral refraction techniques were (a) peripheral refraction using ancillary retinoscope component (P-ARC), (b) retinoscopy with eye rotation, and (c) open-field autorefractor. Peripheral refraction with retinoscopy values was compared with an open-field autorefractor (Shinn Nippon NVision-K) to assess the agreement. All measurements were taken from the right eye under noncycloplegic conditions. Results: The mean difference ±95% limits of agreement of peripheral refraction values obtained using P-ARC from T22° (+0.11 diopters [D] ± 1.20 D; P = 0.20) or N22° (+0.13 D ± 1.16 D; P = 0.13) were comparable with open-field autorefractor. The eye rotation technique compared to autorefractor showed a significant difference for T22° (+0.30 D ± 1.26 D; P = 0.002); however, there was an agreement for N22° (+0.14 D ± 1.16 D; P = 0.10). With respect to the identification of peripheral refraction patterns, examiners were able to identify relative peripheral hyperopia in most of the participants (77%). Conclusions: Peripheral refraction with P-ARC was comparable with open-field autorefractor at T22° and N22° eccentricities. Peripheral retinoscopy techniques can be another approache for estimating and identifying peripheral refraction and its patterns in a regular clinical setting. Translational Relevance: Retinoscope with P-ARC has high potential to guide and enable eye care practitioners to perform peripheral refraction and identify peripheral refraction patterns for effective myopia management.


Assuntos
Hiperopia , Retinoscópios , Adulto Jovem , Humanos , Adulto , Refração Ocular , Testes Visuais , Olho
11.
Invest Ophthalmol Vis Sci ; 65(4): 13, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38573617

RESUMO

Purpose: The purpose of this study was to assess motion-defined form perception, including the association with clinical and sensory factors that may drive performance, in each eye of children with deprivation amblyopia due to unilateral cataract. Methods: Coherence thresholds for orientation discrimination of motion-defined form were measured using a staircase procedure in 30 children with deprivation amblyopia and 59 age-matched controls. Visual acuity, stereoacuity, fusion, and interocular suppression were also measured. Fixation stability and fellow-eye global motion thresholds were measured in a subset of children. Results: Motion-defined form coherence thresholds were elevated in 90% of children with deprivation amblyopia when viewing with the amblyopic eye and in 40% when viewing with the fellow eye. The deficit was similar in children with a cataract that had been visually significant at birth (congenital) and in children for whom the cataract appeared later in infancy or childhood (developmental). Poorer motion-defined form perception in amblyopic eyes was associated with poorer visual acuity, poorer binocular function, greater interocular suppression, and the presence of nystagmus. Fellow-eye deficits were not associated with any of these factors, but a temporo-nasal asymmetry for global motion perception in favor of nasalward motion suggested a general disruption in motion perception. Conclusions: Deficits in motion-defined form perception are common in children with deprivation amblyopia and may reflect a problem in motion processing that relies on binocular mechanisms.


Assuntos
Ambliopia , Catarata , Percepção de Forma , Percepção de Movimento , Recém-Nascido , Criança , Humanos , Olho
12.
BMC Ophthalmol ; 24(1): 146, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38566099

RESUMO

BACKGROUND: Trauma-induced orbital blowout fracture (OBF) with eyeball displacement into the maxillary sinus is rare. CASE PRESENTATION: We present the case of a 14-year-old with a closed head injury, OBF, and displacement of the eyeball into the maxillary sinus following a car accident. A prompt transconjunctival access surgery was performed for eyeball repositioning and orbital reconstruction in a single session, mitigating anaesthesia-related risks associated with multiple surgeries. At the 12-month follow-up, his visual acuity was 20/200. Despite limited eye movement and optic nerve atrophy, overall satisfaction with the ocular appearance was achieved. CONCLUSIONS: This report offers novel insights into the mechanisms of OBF occurrence and the development of postoperative complications.


Assuntos
Traumatismos Cranianos Fechados , Transtornos da Motilidade Ocular , Fraturas Orbitárias , Masculino , Humanos , Adolescente , Seio Maxilar , Olho , Fraturas Orbitárias/complicações , Fraturas Orbitárias/diagnóstico , Fraturas Orbitárias/cirurgia , Traumatismos Cranianos Fechados/complicações
13.
Elife ; 132024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38568729

RESUMO

Primates rely on two eyes to perceive depth, while maintaining stable vision when either one eye or both eyes are open. Although psychophysical and modeling studies have investigated how monocular signals are combined to form binocular vision, the underlying neuronal mechanisms, particularly in V1 where most neurons exhibit binocularity with varying eye preferences, remain poorly understood. Here, we used two-photon calcium imaging to compare the monocular and binocular responses of thousands of simultaneously recorded V1 superficial-layer neurons in three awake macaques. During monocular stimulation, neurons preferring the stimulated eye exhibited significantly stronger responses compared to those preferring both eyes. However, during binocular stimulation, the responses of neurons preferring either eye were suppressed on the average, while those preferring both eyes were enhanced, resulting in similar neuronal responses irrespective of their eye preferences, and an overall response level similar to that with monocular viewing. A neuronally realistic model of binocular combination, which incorporates ocular dominance-dependent divisive interocular inhibition and binocular summation, is proposed to account for these findings.


Assuntos
Dominância Ocular , Olho , Animais , Visão Binocular , Macaca , Neurônios
14.
J Opt Soc Am A Opt Image Sci Vis ; 41(4): 730-738, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568674

RESUMO

Here, we present a full wave propagation model that quantitatively assesses the effect of astigmatism on visual functions in eyes with diffractive bifocal IOLs. The proposed model with bifocal IOLs evaluated the image quality of each focus at varying degrees of corneal astigmatism with the metrics of modulation transfer function and light-in-the-bucket. The results show that corneal astigmatism alters the distance-near image quality balance. Positive (negative) astigmatism has more detrimental effects on far (near) vision. Additionally, bifocal IOLs are more vulnerable to corneal astigmatism, highlighting the need to consider multifocal toric IOLs with astigmatism greater than 1.0 D. The numerical results closely agreed with previous relevant clinical findings, suggesting the clinical usability of the presented method in predicting the postoperative visual function of patients.


Assuntos
Astigmatismo , Lentes Intraoculares , Lentes Intraoculares Multifocais , Humanos , Olho
15.
Int Ophthalmol ; 44(1): 168, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38573375

RESUMO

PURPOSE: To investigate the change in tear production associated with general anesthesia and the protective effect of vitamin A palmitate eye gel on the ocular surface during general anesthesia. METHODS: This double-blind, randomized clinical trial included patients undergoing non-ophthalmic surgery under general anesthesia who randomly received vitamin A palmitate eye gel and taping for one eye (Group A, n = 60) or taping alone for the other eye (Group B, n = 60). Symptom assessment in dry eye (SANDE) score, tear film break-up time (TBUT), corneal fluorescein staining (CFS) score, and Schirmer tear test I (STT-1) were analyzed under a hand-held slit lamp before anesthesia (T0), 0.5 h postoperatively (T1), and 24 h postoperatively (T2). RESULTS: At 0.5 h postoperatively, an increase in CFS score was observed in both groups (P < 0.05 in Group A and P < 0.01 in Group B), and the participants in Group A had less corneal abrasions than those in Group B. STT-1 significantly increased in Group A (P < 0.05), while it significantly decreased in Group B (P < 0.001). The changes between the two groups were statistically significant (P < 0.001). At 24 h postoperatively, both CFS score and STT-1 almost returned to baseline levels in the two groups. In both groups, the SANDE score and TBUT showed little change at 0.5 h and 24 h postoperatively (all P > 0.05). CONCLUSION: Vitamin A palmitate eye gel effectively protected the ocular surface and aqueous supplementation during general anesthesia. TRIAL REGISTRATION: This study was registered in the Chinese Clinical Trial Registry (ChiCTR2100052140) on 20/10/2021.


Assuntos
Diterpenos , Olho , Humanos , Anestesia Geral , Ésteres de Retinil , Géis
16.
Int Ophthalmol ; 44(1): 175, 2024 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-38615085

RESUMO

AIM: This study aimed to assess the efficacy of hp-guar eye drops on tear film index and ocular surface dynamics under desiccating conditions using protection and relief treatment modalities. METHODOLOGY: The 12 normal, non-dry eye participants were subjected to adverse environmental conditions using a Controlled Environment Chamber (CEC) where the relative humidity (RH) was 5% and the ambient temperature was 21 °C. The participants were screened for ocular symptoms, tear osmolarity, ocular surface temperature (OST), tear production using the Ocular Surface Disease Index questionnaire (OSDI), OcuSense TearLab Osmometer, FLIR System ThermaCAM P620, and Schirmer strips. Tear production was calculated by the Tear Function Index test (TFI). RESULTS: The mean tear film osmolarity decreased significantly from 296 mOsm/L at 40% RH to 285 mOsm/L at 5% RH (p = 0.01). Conflicting responses were seen for osmolarity in protection and relief. Mean tear osmolarity was significantly higher in the protection method in comparison to the relief method (p = 0.005). The mean TFI increased from 557 at 40% to 854 at 5% (p = 0.02). A significant increase in TFI was observed in the relief method in comparison with both 40% (p = 0.001) and 5% (p = 0.04). In the relief method, the mean TFI score went up to 1139 when hp-guar was installed. A significant improvement in ocular comfort was experienced in both the protection (p = 0.041) and relief (p = 0.010) methods at 5% RH. The instillation of hp-guar drops in the relief method resulted in a significant reduction in OST. The mean OST dropped to 33.01 ºC, significantly lower than the recorded OST for both normal (p = 0.040) and dry (p = 0.014) environmental conditions. CONCLUSION: Hp-guar drops significantly improve tear film parameters under a desiccating environment, however, tear film parameters respond differently to the management modalities. In the protection method, tear film osmolarity was protected against a dry environment, while in the relief mode, an improvement in tear production and a decrease in ocular surface temperature were seen. Hp-guar performance could be maximized for the management of exposure to adverse environments by using a treatment protocol that targets the most affected parameters in each group of patients. Using CEC has the potential to provide researchers with a readily available method to evaluate the efficiency of tear supplementation.


Assuntos
Cyamopsis , Humanos , Olho , Ambiente Controlado , Soluções Oftálmicas , Concentração Osmolar
17.
18.
Eur J Pharm Biopharm ; 198: 114276, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38582179

RESUMO

The eye is one of the most complex organs in the human body, with a unique anatomy and physiology, being divided into anterior and posterior segments. Ocular diseases can occur in both segments, but different diseases affect different segments. Glaucoma and cataracts affect the anterior segment, while macular degeneration and diabetic retinopathy occur in the posterior segment. The easiest approach to treat ocular diseases, especially in the anterior segment, is through the administration of topical eye drops, but this route presents many constraints, namely precorneal dynamic and static ocular barriers. On the other hand, the delivery of drugs to the posterior segment of the eye is far more challenging and is mainly performed by the intravitreal route. However, it can lead to severe complications such as retinal detachment, endophthalmitis, increased intraocular pressure and haemorrhage. The design of new drug delivery systems for the anterior segment is very challenging, but targeting the posterior one is even more difficult and little progress has been made. In this review we will discuss various strategies including the incorporation of additives in the formulations, such as viscosity, permeability, and solubility enhancers, namely based on Deep eutectic systems (DES). Natural deep eutectic systems (NADES) have emerged to solve several problems encountered in pharmaceutical industry, regarding the pharmacokinetic and pharmacodynamic properties of drugs. NADES can contribute to the design of advanced technologies for ocular therapeutics, including hydrogels and nanomaterials. Here in, we revise some applications of (NA)DES in the development of new drug delivery systems that can be translated into the ophthalmology field.


Assuntos
Oftalmopatias , Degeneração Macular , Humanos , Olho/metabolismo , Oftalmopatias/tratamento farmacológico , Sistemas de Liberação de Medicamentos , Preparações Farmacêuticas , Degeneração Macular/tratamento farmacológico
19.
Transl Vis Sci Technol ; 13(4): 18, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38607633

RESUMO

Purpose: To investigate the visualization capabilities of high-speed swept-source optical coherence tomography (SS-OCT) in cataract surgery. Methods: Cataract surgery was simulated in wet labs with ex vivo porcine eyes. Each phase of the surgery was visualized with a novel surgical microscope-integrated SS-OCT with a variable imaging speed of over 1 million A-scans per second. It was designed to provide four-dimensional (4D) live-volumetric videos, live B-scans, and volume capture scans. Results: Four-dimensional videos, B-scans, and volume capture scans of corneal incision, ophthalmic viscosurgical device injection, capsulorrhexis, phacoemulsification, intraocular lens (IOL) injection, and position of unfolded IOL in the capsular bag were recorded. The flexibility of the SS-OCT system allowed us to tailor the scanning parameters to meet the specific demands of dynamic surgical steps and static pauses. The entire length of the eye was recorded in a single scan, and unfolding of the IOL was visualized dynamically. Conclusions: The presented novel visualization method for fast ophthalmic surgical microscope-integrated intraoperative OCT imaging in cataract surgery allowed the visualization of all major steps of the procedure by achieving large imaging depths covering the entire eye and high acquisition speeds enabling live volumetric 4D-OCT imaging. This promising technology may become an integral part of routine and advanced robotic-assisted cataract surgery in the future. Translational Relevance: We demonstrate the visualization capabilities of a cutting edge swept-source OCT system integrated into an ophthalmic surgical microscope during cataract surgery.


Assuntos
Catarata , Lentes Intraoculares , Oftalmologia , Suínos , Animais , Tomografia de Coerência Óptica , Olho
20.
Sci Rep ; 14(1): 8621, 2024 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-38616214

RESUMO

Fuchs Uveitis Syndrome (FUS), also known as Fuchs Heterochromic Iridocyclitis, is a chronic form of uveitis characterized by mild inflammation primarily affecting one eye. This study aimed to investigate the clinical and epidemiological features of FUS in an Iranian population. A retrospective analysis was conducted on 466 patients diagnosed with FUS at an ophthalmology center affiliated with Isfahan University of Medical Sciences between 2003 and 2021. The Kimura et al. criteria were used for FUS diagnosis. Demographic data, clinical characteristics, misdiagnosed cases, concurrent diseases, and associated ocular findings were analyzed. The study included 507 eyes of 466 FUS patients, with a mean age of 34.01 ± 11.25 years. Iris atrophy, keratic precipitates, and vitritis were common clinical findings. Heterochromia was an infrequent feature. Initial misdiagnosis occurred in 13 patients, with pars planitis being the most common incorrect diagnosis. Toxoplasmosis and multiple sclerosis were common concurrent diseases. Pediatric FUS cases were noted, possibly attributed to early-onset manifestations. Differences in clinical characteristics were observed when compared to other populations. This study provides insights into the clinical and epidemiological aspects of FUS in an Iranian population. Variations in clinical features, misdiagnosis patterns, and concurrent diseases were noted. Attention to specific clinical parameters can aid in accurate FUS diagnosis. Understanding these differences contributes to a better understanding of FUS presentation and its relationship with other diseases.


Assuntos
Iridociclite , Doenças da Íris , Humanos , Criança , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Irã (Geográfico)/epidemiologia , Estudos Retrospectivos , Olho