Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.144
Filtrar
1.
BMC Oral Health ; 24(1): 651, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38831398

RESUMO

BACKGROUND: Carious/Non-carious cervical lesions with gingival recessions may require both dental and periodontal reconstructive therapy, where flaps/grafts may be placed in contact with a dental filling material. Human Gingival Fibroblasts (HGF-1) response during the early phase of healing could vary according to the procedures employed to cure the dental composite. Moreover, oxygen diffusion into dental composite inhibits the polymerization reaction, creating an oxygen-inhibited layer (OIL) that presents residual unreacted monomers. The aim of this study was to assess the effect of different polishing techniques and OIL on HGF-1. METHODS: Composite discs polished with different techniques (diamond rubber, abrasive discs and tungsten carbide burr) were used. An additional not polished smooth group obtained with and without OIL was used as control. Samples were physically characterized through the analysis of their hydrophilicity and surface topography through contact angle measurement and SEM, respectively; afterwards the biologic response of HGF-1 when cultured on the different substrates was analyzed in terms of cytotoxicity and gene expression. RESULTS: The finishing systems caused alterations to the wettability, even if without a proportional relation towards the results of the proliferation essay, from which emerges a greater proliferation on surfaces polished with one-step diamond rubber and with abrasive discs as well as a direct effect of the glycerin layer, confirming that surface roughness can heavily influence the biological response of HGF-1. CONCLUSIONS: Surfaces wettability as well as cellular behavior seem to be affected by the selection of the finishing system used to lastly shape the restoration. Especially, the presence of OIL act as a negative factor in the regards of human gingival fibroblasts. The present study may provide the first clinical instruction regarding the best polishing system of composite material when the restoration is placed directly in contact with soft tissue cells. Understanding HGF-1 behavior can help identifying the polishing treatment for direct restoration of carious/non-carious cervical lesions associated with gingival recessions.


Assuntos
Resinas Compostas , Polimento Dentário , Fibroblastos , Gengiva , Propriedades de Superfície , Humanos , Gengiva/citologia , Polimento Dentário/métodos , Microscopia Eletrônica de Varredura , Proliferação de Células , Molhabilidade , Restauração Dentária Permanente/métodos , Compostos de Tungstênio/farmacologia , Células Cultivadas
2.
Med Sci Monit ; 30: e944502, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38857196

RESUMO

BACKGROUND Before insertion, chairside adjustment kits are heat sterilized for positioning and polishing dental restorations. This study aimed to evaluate the effects of 2 steam sterilization cycles on the efficacy of polishing highly translucent monolithic zirconia (HTMLZ) dental restoration material. MATERIAL AND METHODS 100 HTMLZ disc-shaped specimens were adjusted (grinding, finishing, polishing) with EVE Diacera kit. Two steam sterilization techniques [standard (Gp S), immediate/flash (Gp (F)] of CAK were further subgrouped based on number of sterilization cycles [cycle 1 (control), cycle 5, 10, 15, and 20 (experimental)] (n=10 each). Each subgroup accordingly was evaluated for average surface roughness (Ra) and root mean square roughness (Rq) using a profilometer. Mean and standard deviation of 5 subgroups were statistically analyzed using one-way ANOVA/post hoc Tukey's test. Scanning electron microscopy complemented Ra, Rq measurements. Statistical differences of P≤0.05 were considered significant. RESULTS HTMLZ specimens in both groups showed increased (Ra/Rq) values after repeated sterilization of EVE Diacera kit, with Gp F showing lesser increase than Gp S (20 cycles). Gp F at 10 cycles and Gp S at 15 cycles showed clinically unacceptable roughness threshold (0.25 µm). Differences between subgroups for Ra and Rq values were significant (P≤0.05) with less differences within groups observed in early cycles (1, 10). Results validate the manufacturer's recommendations of using flash sterilization/10 cycles for EVE Diacera kit. CONCLUSIONS Repeated sterilization reduces efficacy of chairside adjustment kit to produce smooth surfaces on HTMLZ. This study recommends flash sterilization to a maximum of 10 times to get the clinically acceptable results of Ra and Rq.


Assuntos
Materiais Dentários , Polimento Dentário , Vapor , Esterilização , Propriedades de Superfície , Zircônio , Esterilização/métodos , Humanos , Polimento Dentário/métodos , Teste de Materiais/métodos , Restauração Dentária Permanente/métodos , Microscopia Eletrônica de Varredura/métodos
3.
Am J Dent ; 37(3): 141-146, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38899994

RESUMO

PURPOSE: To evaluate the effect of air abrasion and polishing procedures on roughness and color stability of ceramic and composite materials after artificial accelerated aging. METHODS: In this study, six restorative materials were tested: feldspathic ceramic (CEREC Blocks), glass ceramic (IPS e.max CAD), resin-based hybrid ceramic (Cerasmart), microhybrid composite (Charisma Classic), nanohybrid composite (Charisma Diamond) and nanoceramic composite (CeramXOne). Forty square-shaped composite specimens were fabricated from each composite and CAD-CAM ceramic material. Initial surface roughness measurements were performed using a profilometer and color measurements of each specimen with a spectrophotometer. Ten control specimens for each group did not receive air abrasion. The other specimens were treated by an air abrasion device and then were randomly divided into three subgroups of 10 specimens (n= 10). After air abrasion, 10 specimens of each group did not receive polishing (Air abrasion group) and others were repolished with Sof-Lex kit (Sof-Lex group) or a rubber kit (Rubber group). Surface roughness and color measurements were repeated before and after 300 hours of artificial accelerated aging (AAA). The univariate test and then three-way ANOVA and two-way ANOVA were performed for comparison of groups (α= 0.05). RESULTS: The univariate statistical analysis revealed that the restorative materials were differently affected after air abrasion, polishing methods and AAA (P< 0.001). Three-way ANOVA showed that the surface roughness of the restorative materials increased after air abrasion and AAA (P< 0.001). Two-way ANOVA showed statistically significant differences between color changes of ceramic (CEREC and IPS e.max CAD) and composite based restorative materials (P< 0.001). CLINICAL SIGNIFICANCE: Clinicians should be aware that air abrasion at a specified power and time significantly changes the surface roughness of the materials except for CEREC. Additionally, polishing procedures (Sof-Lex, Rubber) did not significantly reduce the surface roughness of the ceramic groups. After air abrasion, depending on the material type used clinically, restorations should be repolished to reduce roughness and ensure color stability.


Assuntos
Cerâmica , Cor , Resinas Compostas , Polimento Dentário , Porcelana Dentária , Teste de Materiais , Propriedades de Superfície , Polimento Dentário/métodos , Resinas Compostas/química , Cerâmica/química , Porcelana Dentária/química , Materiais Dentários/química , Abrasão Dental por Ar , Fatores de Tempo , Desenho Assistido por Computador , Silicatos de Alumínio/química , Espectrofotometria , Humanos , Compostos de Potássio/química
4.
Am J Dent ; 37(3): 147-153, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38899995

RESUMO

PURPOSE: To investigate the discoloration, line roughness and gloss of conventional and universal shade resin-based composites. METHODS: Clearfil AP-X (AP-X) and Estelite Sigma Quick (EQ) samples were prepared. Discoloration, roughness, and gloss were measured on mirror-polished, alkaline-degraded, and repolished surfaces. The superficial layer degraded by alkaline immersion (degraded layer) was ground off from the sample surface. After removing the degraded layer, the surface was polished with aluminum oxide powder (1.0 µm and 0.3 µm), to create a repolished specimen. Scanning electron microscopy observations were made of the specimens. RESULTS: The results were compared with those for Omnichroma (OC) from a previous study. All the materials showed different responses to degradation and repolishing, but repolishing of AP-X, for surface roughness and gloss, was more effective at restoring pre-degradation properties. Repolishing effectively removed discoloration in all materials. CLINICAL SIGNIFICANCE: The materials tested showed different responses to degradation and repolishing, but repolishing of AP-X, for surface roughness and gloss, was more effective at restoring pre-degradation properties. Repolishing effectively removed discoloration in all materials.


Assuntos
Cor , Resinas Compostas , Propriedades de Superfície , Resinas Compostas/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Polimento Dentário/métodos , Óxido de Alumínio/química
5.
Am J Dent ; 37(3): 159-163, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38899997

RESUMO

PURPOSE: To evaluate different polishing methods' effects on the color stability of recent resin composites. METHODS: 160 samples for color stability evaluation and 40 samples for the degree of conversion evaluation were prepared with four different resin composites [Harmonize (H), Filtek Universal (F), Omnichroma (O), Essentia Universal (E)] and light cured. For color stability evaluation, samples prepared from each resin composite were divided into four groups: three polishing procedures and a control group. The ΔE00 was calculated between initial, and after immersion in coffee solution for 12 days. The degree of conversion was evaluated with Fourier Transform Infrared Spectroscopy. The statistical analysis of ΔE00 values was made with the two-way ANOVA, Tukey HSD, and Tamhane's T2 tests. One-way ANOVA and Tukey HSD tests were used to compare the degree of conversion values (P< 0.05). RESULTS: In all composite groups, mylar (control) groups had the highest ΔE00, and no differences between other polishing procedures. According to the polishing procedures, Omnichroma showed the highest ΔE00 values (on mylar groups O vs F, P< 0.001; O vs H, P< 0.001; O vs E, P< 0.001). There was a significant difference between the composite groups in terms of the degree of monomer conversion (P< 0.05). Omnichroma showed, significantly, the highest discoloration. CLINICAL SIGNIFICANCE: Different polishing procedures showed effective performance on current composite surfaces. Omnichroma resin composite showed higher color change than composites with similar properties.


Assuntos
Cor , Resinas Compostas , Polimento Dentário , Resinas Compostas/química , Polimento Dentário/métodos , Propriedades de Superfície , Teste de Materiais , Espectroscopia de Infravermelho com Transformada de Fourier
6.
BMC Oral Health ; 24(1): 712, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38902697

RESUMO

OBJECTIVE: To evaluate the effects of different polishing techniques and coffee staining on the color stability of four commercially available bleach-shade composite resins, namely microhybrid, nanohybrid, nanofilled, and injectable nanohybrids. MATERIAL AND METHODS: A total of 224 discs (8 mm diameter and 2 mm thickness) were fabricated from four different bleach-shade composite resins, namely microhybrid (Gradia Direct Anterior), nanohybrid (Palfique LX5), nanofilled (Filtek Universal), and injectable nanohybrid (flowable G-aenial universal injectable). The composite resin groups were polished via four techniques: no polishing, 4-step polishing using aluminum oxide discs, 3-step polishing using silicon rubber diamond discs, and one-step polishing. Half of each group was immersed in water, while the other half was immersed in coffee for 12 days (n = 7). Colors were measured using a clinical spectrophotometer, and color differences were calculated (ΔE). The results were analyzed statistically. RESULTS: The alterations in color were significantly influenced by the techniques employed for finishing and polishing techniques, composite resin type, and degree of coffee staining. Regardless of the polishing technique and storage medium, different material types showed a significant color change (ΔE) at P < 0.001. Filtek exhibited the most significant color change, followed by Gradia and Palfique, with no significant differences between them. In addition, Different polishing techniques resulted in significant color changes (P < 0.001). The highest degree of color change was seen in the no-polishing group, followed by the 4-step and 1-step polishing groups, with negligible differences between each other. Also, Storage media had a significant effect on ΔE values. CONCLUSION: Appropriate finishing and polishing procedures can improve the color stability of bleach-shaded composite resins. Coffee has a deleterious effect on color; however, injectable flowable nanohybrid composites are more resistant to staining.


Assuntos
Óxido de Alumínio , Café , Cor , Resinas Compostas , Polimento Dentário , Propriedades de Superfície , Resinas Compostas/química , Polimento Dentário/métodos , Óxido de Alumínio/química , Teste de Materiais , Espectrofotometria , Técnicas In Vitro , Humanos , Diamante/química , Nanocompostos/química , Clareadores Dentários/química , Água/química , Materiais Dentários/química , Fatores de Tempo
7.
Am J Dent ; 37(2): 66-70, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38704848

RESUMO

PURPOSE: To evaluate the effect of different finishing and polishing systems on the surface roughness of a resin composite subjected to simulated saliva-, acid-, and enzyme-induced degradation. METHODS: 160 specimens (n= 40) were fabricated with Filtek Z350 XT nanofilled composite and analyzed for average surface roughness (Ra). The specimens were finished and polished using: AD - Al2O3-impreginated rubberized discs (medium, fine, and superfine grit, Sof-Lex); SD - silicon carbide and Al2O3-impregnated rubberized discs (coarse, medium and fine grit, Jiffy,); MB - 12- and 30-multiblade burs. The control group (CT) (n= 40) comprised specimens with a Mylar-strip-created surface. Specimens from each group were immersed in 1 mL of one of the degradation methods (n= 10): artificial saliva (ArS: pH 6.75), cariogenic challenge (CaC: pH 4.3), erosive challenge (ErC: 0.05M citric acid, pH 2.3) or enzymatic challenge (EzC: artificial saliva with 700 µg/mL of albumin, pH 6.75). The immersion period simulated a time frame of 180 days. Ra measurements were also performed at the post-polishing and post-degradation time points. The data were evaluated by three-way ANOVA for repeated measures and the Tukey tests. RESULTS: There was significant interaction between the finishing/polishing system and the degradation method (P= 0.001). AD presented the greatest smoothness, followed by SD. After degradation, CT, AD and SD groups became significantly rougher, but not the MB group, which presented no difference in roughness before or after degradation. CT and AD groups showed greater roughness in CaC, ErC and EzC than in ArS. The SD group showed no difference in roughness when the specimens were polished with CaC, EzC or ArS, but those treated with ErC had greater roughness. In the MB group, the lower roughness values were found after using CaC and EzC, while the higher values were found using ErC or ArS. CLINICAL SIGNIFICANCE: As far as degradation resistance of nanofilled composite to hydrolysis, bacterial and dietary acids and enzymatic reactions is concerned, restorations that had been finished and polished with Al2O3-impregnated discs had the smoothest surfaces.


Assuntos
Óxido de Alumínio , Resinas Compostas , Polimento Dentário , Saliva Artificial , Compostos de Silício , Propriedades de Superfície , Resinas Compostas/química , Polimento Dentário/métodos , Humanos , Saliva Artificial/química , Concentração de Íons de Hidrogênio , Óxido de Alumínio/química , Compostos de Silício/química , Compostos Inorgânicos de Carbono/química , Teste de Materiais , Nanocompostos/química , Ácido Cítrico/química , Saliva/enzimologia , Saliva/metabolismo , Saliva/química , Erosão Dentária , Borracha/química , Materiais Dentários/química
8.
Am J Dent ; 37(2): 101-105, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38704853

RESUMO

PURPOSE: To evaluate the effect of toothbrushing with conventional and whitening dentifrices on the color difference (ΔE00), gloss (Δgloss), and surface roughness (SR) of stained stabilized zirconia with 5 mol% of yttrium oxide (5Y-TZP) after polishing or glazing. METHODS: Specimens were divided into four groups (n=20): C (control), S (staining), SG (staining and glazing) and SP (staining and polishing). 50,000 toothbrushing cycles were performed with conventional (n=10) and whitening (n= 10) dentifrice slurries. The ΔE00 and Δgloss were measured using a spectrophotometer and CIEDE2000 system while SR was measured by laser confocal microscope. The ΔE00 and Δgloss data were analyzed using 2-way ANOVA, and SR data were analyzed using the linear repeated measures model, with Bonferroni's complementary test (α= 0.05). RESULTS: The ΔE00 values were beyond the acceptability threshold and no differences were found among the groups. There was no difference among groups to Δgloss after toothbrushing with conventional dentifrice while SP presented the highest values of Δgloss after toothbrushing with whitening dentifrice. Conventional dentifrice decreased the SR of stained groups and whitening dentifrice decreased SR of S and SG. The toothbrushing with conventional and whitening dentifrices promoted color difference, but did not impair gloss and surface roughness of stained 5Y-TZP. CLINICAL SIGNIFICANCE: Monolithic zirconia has been routinely used for esthetic restorations, however the type of finishing procedures that is carried out on it must be taken into consideration, in addition to the fact that brushing can influence the color difference of the material as well as interfere with surface roughness and gloss.


Assuntos
Dentifrícios , Propriedades de Superfície , Escovação Dentária , Zircônio , Zircônio/química , Dentifrícios/uso terapêutico , Cor , Clareadores Dentários/uso terapêutico , Polimento Dentário/métodos , Ítrio/química , Humanos , Teste de Materiais , Clareamento Dental/métodos , Espectrofotometria , Microscopia Confocal
9.
BMC Oral Health ; 24(1): 609, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38796434

RESUMO

BACKGROUND: High speed electric handpieces have recently been growing in popularity among dental professionals. Advantages include smoother surface preparation and increased cutting efficiency. AIM: The primary objective was to compare enamel surface roughness following resin cleanup after bracket debonding using highspeed air turbine versus electric handpiece. The secondary objective was to record the time needed for resin-clean up. METHOD: Forty deidentified freshly extracted human premolars were cleaned and sectioned at the cement-enamel junction. The crowns were embedded in acrylic blocks. Enamel surface roughness parameters (Ra, Rz, Rp and Rv) were measured using a stylus profilometer. Brackets were bonded using a light-cure orthodontic adhesive and stored in distilled water for 24 h. Following bracket debonding, the specimens were randomly divided into 2 groups: First group: resin clean-up was carried out using a 12-fluted carbide bur mounted on a high-speed air turbine; and second group: where an electric handpiece was used. Surface roughness parameters were measured following resin clean up and after polishing using pumice and a rubber cup. Time needed for resin clean-up was recorded. Differences in enamel surface roughness and time between groups were compared using repeated measures ANOVA and independent samples t-test, respectively at P ≤ 0.05. RESULTS: The electric handpiece groups showed significantly higher values for Ra, Rz and Rp both following resin cleanup and polishing. Time taken for resin cleanup was significantly longer for the electric handpiece group. CONCLUSION: Considering both surface roughness and time, electric handpiece do not seem to add greater effectiveness or efficiency to resin cleanup following orthodontic bracket debonding.


Assuntos
Descolagem Dentária , Esmalte Dentário , Equipamentos Odontológicos de Alta Rotação , Propriedades de Superfície , Humanos , Descolagem Dentária/métodos , Técnicas In Vitro , Cimentos de Resina/química , Braquetes Ortodônticos , Fatores de Tempo , Dente Pré-Molar , Polimento Dentário/métodos
10.
Clin Exp Dent Res ; 10(3): e884, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38798053

RESUMO

OBJECTIVES: This study compared the effects of glazing versus polishing on mechanical, optical, and surface properties of zirconia ceramics with different translucencies. MATERIALS AND METHODS: In this in vitro study, 120 bar-shaped specimens (25 × 4 × 1.2 mm) were fabricated from three different types of zirconia with different translucencies (n = 40, DD Bio ZW, ZX2, and Cube X2). After sintering, each zirconia group was randomly divided into five subgroups of control (glazing), glazing + bur abrasion, glazing + bur abrasion + polishing with EVE Diacera® kit, glazing + bur abrasion + reglazing, and glazing + bur abrasion + polishing with EVE Diacera® kit + reglazing. The specimens underwent surface roughness, hardness, flexural strength, and translucency tests, as well as X-ray diffraction (XRD) and scanning electron microscopy (SEM) for assessment of surface topography. Data were analyzed by one-way analysis of variance, Tukey test, and Pearson test (α = .05). RESULTS: Flexural strength, surface hardness, and translucency were significantly correlated with zirconia type. ZW zirconia had significantly higher flexural strength and surface hardness and significantly lower translucency than Cube X2 and ZX2 (p < .001). Surface roughness had no significant correlation with zirconia type (p = .274). Polishing created the smoothest, and bur abrasion created the roughest surface (p < .001). Flexural strength and hardness in most experimental groups were significantly lower than in the control group (p < .001). Translucency was not significantly different in bur abrasion and polishing groups, compared with the control group; however, reglazing significantly increased the translucency (p < .001). SEM micrographs confirmed the surface roughness results. XRD showed monoclinic phase only in reglazed groups. CONCLUSION: Of different surface treatments, polishing improved the surface properties and caused the smallest change in mechanical properties of zirconia with different translucencies.


Assuntos
Cerâmica , Polimento Dentário , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Zircônio , Zircônio/química , Polimento Dentário/métodos , Cerâmica/química , Dureza , Materiais Dentários/química , Resistência à Flexão , Difração de Raios X , Técnicas In Vitro
11.
BMC Oral Health ; 24(1): 558, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38741081

RESUMO

BACKGROUND: We investigated the efficacy of two different cold atmospheric pressure jet plasma devices (CAP09 and CAPmed) and an air polishing device with glycine powder (AP) either applied as monotherapies or combined therapies (AP + CAP09; AP + CAPmed), in microbial biofilm removal from discs with anodised titanium surface. METHODS: Discs covered with 7-day-old microbial biofilm were treated either with CAP09, CAPmed, AP, AP + CAP09 or AP + CAPmed and compared with negative and positive controls. Biofilm removal was assessed with flourescence and electron microscopy immediately after treatment and after 5 days of reincubation of the treated discs. RESULTS: Treatment with CAP09 or CAPmed did not lead to an effective biofilm removal, whereas treatment with AP detached the complete biofilm, which however regrew to baseline magnitude after 5 days of reincubation. Both combination therapies (AP + CAP09 and AP + CAPmed) achieved a complete biofilm removal immediately after cleaning. However, biofilm regrew after 5 days on 50% of the discs treated with the combination therapy. CONCLUSION: AP treatment alone can remove gross biofilm immediately from anodised titanium surfaces. However, it did not impede regrowth after 5 days, because microorganisms were probably hidden in holes and troughs, from which they could regrow, and which were inaccessible to AP. The combination of AP and plasma treatment probably removed or inactivated microorganisms also from these hard to access spots. These results were independent of the choice of plasma device.


Assuntos
Biofilmes , Implantes Dentários , Gases em Plasma , Propriedades de Superfície , Titânio , Biofilmes/efeitos dos fármacos , Titânio/química , Implantes Dentários/microbiologia , Polimento Dentário/métodos , Glicina , Humanos , Técnicas In Vitro , Microscopia Eletrônica de Varredura , Níquel
12.
J Dent ; 146: 105101, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38801940

RESUMO

OBJECTIVE: To evaluate the effect of polishing and layering thickness on the wear resistance of 3D-printed occlusal splint materials. METHODS: Specimens with 3 different layer thicknesses (50, 75, 100 µm) were produced in the form of a disc 3 mm thick using V-Print splint resin on a 3D-printer with digital light processing technology. (n = 16 for each thickness) All specimens were washed and cured according to the manufacturer's instructions. Half of the specimens of each layer thickness were polished with silicon carbide papers. All specimens were subjected to 120.000 cycles of a chewing simulator for 2-body wear tests. Before and after the wear test, the specimens were scanned with a laser scanner, and the images were overlaid using a 3D analysis program and the volume loss was calculated. The wear patterns of the specimens were examined under a scanning electron microscope. Statistical evaluation was performed using a Shapiro-Wilk test, 2-way ANOVA, 1-way ANOVA, and Tukey post hoc test (α = 0.05). RESULTS: While polishing had a significant effect (p = 0.003) on the wear volume of the occlusal splints, layer thickness (p = 0.105) and their interaction between polishing and layer thickness (p = 0.620) did not significantly affect the wear volume. Regardless of the polishing, the lowest mean wear was observed for D50 (0.064 mm3), followed by D75 (0.078 mm3), and D100 (0.096 mm3). However, a significant difference was observed only between polished D50 and unpolished D100. CONCLUSION: The polished 3D-printed occlusal splint resin showed higher wear resistance than the unpolished one, regardless of the layer thickness. CLINICAL SIGNIFICANCE: Since different layer thicknesses of 50 µm and greater had no effect on the wear resistance of the material, a layer thickness of 100 µm may be preferred for faster printing. However, polishing occlusal splints may reduce the amount of wear and improve clinical performance.


Assuntos
Polimento Dentário , Teste de Materiais , Microscopia Eletrônica de Varredura , Placas Oclusais , Impressão Tridimensional , Propriedades de Superfície , Polimento Dentário/métodos , Humanos , Compostos Inorgânicos de Carbono/química , Compostos de Silício/química , Desgaste de Restauração Dentária , Lasers , Materiais Dentários/química , Desenho Assistido por Computador , Mastigação/fisiologia
13.
Niger J Clin Pract ; 27(4): 496-503, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38679773

RESUMO

BACKGROUND: Monolithic zirconia restorations can be produced from self-colored or uncolored blocks. The coloring procedure of uncolored blocks and surface treatments may affect the appearance of the restoration. AIM: The purpose of this study is to evaluate the effect of liquid coloring and surface treatments on optical properties of translucent monolithic zirconia. METHODS: All specimens were cut from zirconia blocks with a thickness of 1 mm. Specimens were dipped in the coloring liquids for 3 min, 5 min, and 7 min and then divided into groups of 10 specimens for surface treatments. Glaze and mechanical polishing were applied, and the color of the specimens was measured under the D65 lighting condition with a spectrophotometer device. Color values obtained from the CIE Lab formula and the translucency parameter (TP), opalescence parameter (OP), and contrast ratio (CR) were calculated. The normality of the data was confirmed with the Shapiro-Wilk test. A three-way analysis of variance (ANOVA) was used to assess the effect of dipping time, liquid shade, and surface treatments. RESULTS: The effect of liquid shade and dipping time on the TP, OP, and CR parameters were statistically significant, and the TP values were reduced with the application of coloring liquid. Mechanical polishing groups had higher OP values and lower TP values than glazed groups. CONCLUSION: In cases where high translucency is required, it may be advisable to use self-colored blocks and apply glaze as a surface treatment to achieve the desired optical properties.


Assuntos
Propriedades de Superfície , Zircônio , Zircônio/química , Humanos , Teste de Materiais , Cor , Espectrofotometria , Materiais Dentários/química , Fatores de Tempo , Corantes , Polimento Dentário/métodos
14.
J Dent ; 144: 104918, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38461887

RESUMO

OBJECTIVE: To determine the effect of airborne particle abrasion (APA) on micro-tensile bond strength (µTBS) to dentin using different air-abrasion/polishing powders. METHODS: The bonding effectiveness of G2 Bond Universal (G2B), used in etch-and-rinse (E&R) and self-etch mode (SE), was tested on bur-cut dentin and dentin air abraded/polished using six different powders (aluminum oxide 29 µm (AO29) and 53 µm (AO53), aluminum trihydroxide (AT), sodium bicarbonate (SB), sodium bicarbonate soft (SBsoft) and bioactive glass (BG); Velopex). Adhesive-composite resin specimens were immersed in distilled water at 37 °C for one week and cut into microspecimens. Half of the specimens were subjected to 50,000 thermocycles (aged). Immediate and aged µTBS to dentin were measured. Statistical analysis was performed using linear mixed-effects (LME) modeling (p < 0.05). RESULTS: Comparing the aged bond strengths to air-abraded/polished dentin with bur-cut dentin, pretreatment with SB and SBsoft in combination with G2B used in E&R mode, and BG air polishing in combination with both application modes (E&R, SE), resulted in a significantly higher bond strength. Dentin bond strength was only significantly lower when air abraded with AO29 and using G2B in SE mode. Aging did not significantly influence bond strength for both application modes (E&R, SE), except for AO29 and AT-treated dentin, where bond strengths decrea sed significantly using G2B in SE mode. In general, G2B reached significantly higher bond strengths on air-abraded/polished dentin in E&R mode than in SE mode. CONCLUSION: Air-abrasion/polishing did not impair dentin bond strength using G2B, except when dentin was air abraded with AO29 and using G2B in SE mode. Air polishing positively influenced the bond strength to dentin in specific groups. CLINICAL SIGNIFICANCE: APA is safe concerning bonding to dentin. The E&R application mode is preferred using G2B as adhesive on air-abraded/polished dentin. Air polishing with BG positively influenced dentin bond strength for both application methods.


Assuntos
Abrasão Dental por Ar , Resinas Compostas , Colagem Dentária , Adesivos Dentinários , Dentina , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície , Resistência à Tração , Colagem Dentária/métodos , Humanos , Resinas Compostas/química , Adesivos Dentinários/química , Cimentos de Resina/química , Análise do Estresse Dentário , Condicionamento Ácido do Dente/métodos , Polimento Dentário/métodos , Estresse Mecânico , Materiais Dentários/química , Pós
15.
BMC Oral Health ; 24(1): 287, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38419033

RESUMO

BACKGROUND: As superior esthetic is one of the main reasons for using composite resins, it is very important to be familiar with factors and techniques affecting their optical properties and appearance. AIM: The aim of this study was comparing the effect of finishing and polishing with and without water coolant, on the color change and opacity of composite resin materials. METHODS: Composites used for preparing samples were Z250 (microhybrid), Z350XT (nanofilled), and Z550 (nanohybrid). Then divided into 4 groups of 5 depending on finishing and polishing technique (dry or wet) and time (immediate and after twenty-four hours). After polishing, samples were assessed using a spectrophotometer. Color change and opacity were determined. Data was analyzed using Kolmogorov-Smirnov, ANOVA and Tukey HSD tests. RESULTS: Type of material at both time had a significant effect on ΔE and opacity. Our results in dry and wet technique immediately(T0) showed that the highest and lowest ΔE and opacity belong to Z350XT (p < 0.001). After Twenty-four hours (T24), opacity of Z250 in wet condition was higher than dry condition (p < 0.001). CONCLUSIONS: Wet or dry technique was only effective on color in immediate polishing. Regarding opacity, technique was only effective in case of delayed polishing.


Assuntos
Resinas Compostas , Polimento Dentário , Humanos , Cor , Polimento Dentário/métodos , Teste de Materiais , Propriedades de Superfície , Resinas Compostas/uso terapêutico
16.
J Prosthet Dent ; 131(1): 164.e1-164.e11, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37945513

RESUMO

STATEMENT OF PROBLEM: High translucency zirconia (HTZ) has gained popularity as an esthetic computer-aided design and computer-aided manufacturing (CAD-CAM) material for monolithic restorations. A detailed comparison between different common surface and heat treatments with a non-treated HTZ control to explain the behavior of the material under stress is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the effect of different surface and heat treatments on the surface roughness parameters (SRPs), topography, crystallography, and phase composition of HTZ used for monolithic restorations. MATERIAL AND METHODS: Ninety Ø11.9×1.18-mm HTZ disks (Prettau Anterior) were milled, sintered, and distributed into 9 groups (n=10); 8 experimental (coarse diamond grinding GC, fine diamond grinding GF, fine diamond grinding and 3-step polishing kit GF+P1, fine diamond grinding and 3-step polishing kit and diamond paste GF+P1+DP, fine diamond grinding and 2-step polishing kit GF+P2, fine diamond grinding and GF+Gl, fine diamond grinding and 3-step polishing and glazing GF+P1+Gl, airborne-particle abrasion with 50-µm alumina), and a control group (C, as-sintered). SRPs (AveSa, AveSv, AveSz) and 3-dimensional (3D) images were obtained using a noncontact 3D-optic-profilometer. The crystal structure was determined with scanning electron microscopy. Phase composition was analyzed by X-ray diffraction (XRD). Surface roughness parameters data were statistically analyzed by 1-way ANOVA and the Tukey HSD test (α=.05). RESULTS: The applied surface and heat treatment resulted in significantly different SRP mean values (P<.001) with different topographies. GC had the highest AveSa, AveSv, and AveSz mean values (0.95, 8.8, 17.4 µm, respectively) with significant microcracks. GF had significantly lower SRP with finer microcracks. GF+P1 had a significantly smoother surface, but GF+P2 resulted in SRP comparable with the GF group. GF+P1+DP had the smoothest homogenous surface (mean Sa: 0.08 µm). GF+P1 and GF+GL were equally effective, while GF+P1+GL was not superior. Airborne-particle abrasion produced a low Sa mean value (0.11 µm) with relatively high Sv and Sz mean values (5.9, 9.2 µm, respectively) and microcracks. A monoclinic phase was detected in all groups. All experimental groups had broadened XRD-peaks with lower intensity, suggesting the presence of the rhombohedral phase. CONCLUSIONS: The different surface and heat treatments altered the HTZ crystals and their surface roughness with distinct topographies. Cubic crystal changes take place under stress as shown by the scanning electron microscope and the XRD diffraction pattern and may transform to the rhombohedral phase.


Assuntos
Polimento Dentário , Temperatura Alta , Teste de Materiais , Cristalografia , Polimento Dentário/métodos , Propriedades de Superfície , Estética Dentária , Zircônio/química , Microscopia Eletrônica de Varredura , Diamante/química , Cerâmica/química
17.
Minerva Dent Oral Sci ; 73(1): 7-13, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37768687

RESUMO

BACKGROUND: Interproximal enamel reduction (IPR) is a clinical procedure which involves reduction and anatomic recontouring of interproximal surfaces of enamel as a method of gaining space. The biological effects related to this clinical procedure have long been discussed. Thus, the aim of this study was to evaluate the enamel reduction efficiency and the effects on enamel surfaces of the oscillating mechanical system for interproximal enamel reduction (IPR). METHODS: Fifteen complete oscillating IPR sequences included one opener (0.1 mm), two metallic strips for active IPR phase (0.2 and 0.3 mm), three resin strips for active and initial polishing phases (0.4 and 0.5 mm), and one resin strip for polishing phase (0.15 mm). Sequences were selected and tested on fifteen freshly extracted teeth by means of tribological tests with alternative dry-sliding motion (Linear Reciprocating Tribometer; C.S.M. Instruments, Peseaux, Switzerland). A 3D analysis of treated surfaces was performed by using a TayMap software. Then, enamel surfaces were qualitatively evaluated before and after the tribological analysis, with a FEI Quanta 200 (FEI, Hillsboro, OR, USA) in high vacuum at 30.00 kV. Images were acquired at a 30×, 100× and 300× magnification. RESULTS: Minimum surface irregularities were observed on all treated enamel surfaces when compared with untreated ones. The 3D analysis showed a uniform wear pattern after tribological tests. Meanwhile, the SEM analysis revealed smooth and regular wear lines on treated surfaces after the entire mechanical IPR sequence. The macroscopic irregularities illustrated can be considered similar to those of untreated surfaces. CONCLUSIONS: The adoption of a standardized oscillating IPR sequence allows an efficient reduction of the interproximal enamel, leaving regular and harmonious surfaces. Adequate polishing procedures should always be performed at the end of active IPR phases in order to guarantee a good long-term prognosis and proper respect of biological structures.


Assuntos
Esmalte Dentário , Polimento Dentário , Polimento Dentário/métodos , Microscopia Eletrônica de Varredura , Extração Dentária , Movimento (Física)
18.
Am J Dent ; 36(6): 274-280, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38092745

RESUMO

PURPOSE: To evaluate the impact of simplified or multi-step polishing techniques on the roughness, color, and susceptibility to staining of different resin composites. METHODS: Discs (Ø6 mm x 2 mm) were obtained from different resin composites [nanofilled (Z350XT), suprananofilled (Estelite Omega), and nanohybrid (Forma)]. The specimens (n= 15) were submitted to a simplified protocol using abrasive discs (Sof-Lex) and spiral discs (Diacomp Plus Twist), or a multi-step protocol using abrasive discs (Sof-Lex), abrasive points (Jiffy), silicon carbide brush and felt disc with diamond pastes (Diamond Polish). The specimens were evaluated initially for roughness (Ra) and color (CIEL*a*b*, CIEDE 2000), after completing the polishing protocol, and after exposure to a coffee solution (pH= 5.01). The data were analyzed according to the variables, using generalized linear models, and the Friedman, Nemenyi, Kruskal-Wallis, Dunn, and Mann-Whitney tests (α= 0.05). RESULTS: The nanohybrid resin composite showed an increase in Ra following use of both polishing methods (P= 0.038). Both techniques promoted an increase in L* values after polishing; however, the general color changes (ΔEab and ΔE00) were greater after the multi-step polishing (P< 0.05). After immersion in coffee, the multi-step polished groups of the nanohybrid and suprananofilled resin composite showed higher L* values than the simplified polishing groups (P= 0.023), and the nanofilled resin composite showed higher ΔEab and ΔE00 values than the other resin composites, regardless of the polishing technique (P< 0.05). CLINICAL SIGNIFICANCE: The choice of the resin composite had a greater effect on roughness, color stability and susceptibility to staining than the polishing technique. However, luminosity after coffee staining was higher with the multi-step polishing technique.


Assuntos
Café , Polimento Dentário , Polimento Dentário/métodos , Propriedades de Superfície , Teste de Materiais , Resinas Compostas , Diamante , Cor
19.
Gen Dent ; 71(6): 61-67, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37889246

RESUMO

This study aimed to use spectrophotometry to assess the color stability of composite resins polished with different polishing techniques and scanning electron microscopy (SEM) to evaluate the surface micromorphology of the specimens. In this in vitro experimental study, a total of 96 disc-shaped specimens were fabricated from microfilled (Renamel Microfill, shade SB3) and nanohybrid (Estelite Sigma Quick, shade BW) composite resins in bright white shades (n = 48). Each group was randomized into 1 control and 2 experimental subgroups (n = 16): no polishing (control), polishing with aluminum oxide discs (experimental), or polishing with diamond-impregnated spiral wheels (experimental). In each subgroup, half of the specimens were immersed in a coffee solution and the other half in a tea solution for 48 hours after finishing (control) or polishing (experimental). Spectrophotometry was used to measure the color of the specimens at baseline, after finishing, after polishing (experimental groups only), and after immersion in tea and coffee. The surface micromorphology of a randomly selected specimen from each subgroup was assessed under SEM. The color change (ΔE*) of the specimens between measurements was calculated and analyzed using 1-way, 2-way, and 3-way analyses of variance (ANOVAs) and the Tukey test. Both tea and coffee caused significant color change in the composite resin specimens, with specimens immersed in coffee undergoing significantly greater color change than those immersed in tea (P < 0.001; 2-way ANOVA). The nanohybrid composite specimens polished with polishing discs had a significantly greater color change than nanohybrid specimens polished with spiral wheels (P = 0.041). The Tukey test revealed that there was no overall significant difference between the 2 polishing techniques (P = 0.505), but both of these subgroups exhibited a significantly lower color change than the control group (P < 0.001). In general, SEM did not reveal substantial differences between the 2 polishing techniques, but specimens polished by spiral wheels appeared to have a smoother surface. All polished specimens demonstrated clinically acceptable mean color change values (ΔE* < 3.5). The type of coloring agent had a greater effect on color stability than either the polishing technique or type of composite resin, with coffee causing a greater color change than tea.


Assuntos
Café , Resinas Compostas , Humanos , Resinas Compostas/uso terapêutico , Espectrofotometria , Chá , Propriedades de Superfície , Teste de Materiais , Cor , Polimento Dentário/métodos
20.
Oper Dent ; 48(6): 689-699, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37881035

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the effectiveness of glazing, two zirconia, and two lithium disilicate polishing systems on surface roughness of a CAD/CAM lithium disilicate and virgilite ceramic with atomic force microscopy (AFM) and visual assessment performed by dental students and faculty. METHODS AND MATERIALS: Sixty maxillary right central incisor crowns made of a novel chairside CAD/CAM lithium disilicate and virgilite (CEREC Tessera) were milled for glazing and polishing. The crowns were divided into six groups: no polishing/glazing provided (NoP/G); glazed (GZ); glazed and polished with Brasseler Dialite LD Lithium Disilicate (DiLD); glazed and polished with Meisinger Luster Lithium Disilicate (LuLD); glazed and polished with Brasseler Dialite ZR Zirconia (DiZR); and glazed and polished with Meisinger Luster Zirconia (LuZR). Surfaces were scanned with AFM to measure roughness (Ra) and root mean square roughness (Rq) and generate micrographs. Crowns were visually assessed by 10 dental students and 10 dental school faculty members to determine clinical acceptableness. RESULTS: Glazing and all polishing kits significantly reduced Ra and Rq compared to no polishing/glazing. No significant Ra differences were found between glazing and all polishing kits (p>0.05). DiZR significantly reduced Rq compared to other groups (p<0.05). Visual assessment showed that GZ, LuLD, and DiZR were the most clinically acceptable crowns. CONCLUSION: Polishing and glazing considerably improve the surface smoothness of maxillary central incisor crowns fabricated out of a chairside CAD/CAM lithium disilicate and virgilite ceramic. Altogether, zirconia polishing systems provided smoother and more clinically acceptable surfaces than the lithium disilicate kits.


Assuntos
Polimento Dentário , Porcelana Dentária , Humanos , Teste de Materiais , Polimento Dentário/métodos , Propriedades de Superfície , Cerâmica , Coroas , Desenho Assistido por Computador , Microscopia Eletrônica de Varredura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA